Steps to report each lighting projectUsing the PTR system
Go to PTR web site and download calculator Save calculator to your computer. Take care naming each project
as a separate file. For example: LC-JonsPetShop-06-v1.xls Perform calculations & fill out site audit page Don’t forget, save calculator as a separate file (as named above) After final inspection of project:
go into calculator for true-up, re-save final version of file, then upload calculator into project shopping cart
Finally, create invoice to claim funds
![Page 3: Using PTR: Lighting Utility Brown Bag Session September 15, 2006](https://reader036.vdocuments.us/reader036/viewer/2022082821/5697bfbd1a28abf838ca1c61/html5/thumbnails/3.jpg)
3
PTR Web Site – Step 1 of 4
Click on the “Commercial”
link at left
![Page 4: Using PTR: Lighting Utility Brown Bag Session September 15, 2006](https://reader036.vdocuments.us/reader036/viewer/2022082821/5697bfbd1a28abf838ca1c61/html5/thumbnails/4.jpg)
4
PTR Web Site – Step 2 of 4
Select “Retrofit” from the New and Retrofit
Lighting Projects drop-down box
![Page 5: Using PTR: Lighting Utility Brown Bag Session September 15, 2006](https://reader036.vdocuments.us/reader036/viewer/2022082821/5697bfbd1a28abf838ca1c61/html5/thumbnails/5.jpg)
5
PTR Web Site – Step 3 of 4
Click on the “Lamp & Ballast”
link
![Page 6: Using PTR: Lighting Utility Brown Bag Session September 15, 2006](https://reader036.vdocuments.us/reader036/viewer/2022082821/5697bfbd1a28abf838ca1c61/html5/thumbnails/6.jpg)
6
PTR Web Site – Step 4 of 4
Click on the “Standard Offer Lighting
Spreadsheet Tool” link
![Page 7: Using PTR: Lighting Utility Brown Bag Session September 15, 2006](https://reader036.vdocuments.us/reader036/viewer/2022082821/5697bfbd1a28abf838ca1c61/html5/thumbnails/7.jpg)
7
Version 1.4 9/7/2006
Main Warehouse
97058
NW Public Power A-12456Line No.
1 20,864 sf
2 -$1,274.37
3 Other Commercial
4 Heat Pump
5 57,678 Watts
6 29,789 Watts
7 307,282 kWh
8 $39,000.00
9 -$12,743.72
10 4,000 hours
11
12 12 years
13 11,018 hours
14 102%
15 313,428 kWh
16 337,326 kWh
17 48%
18 $0.063 /kWh
19 $19,589
20 2.0 years
21 15 kWh
22 1.34 Watts/sf
23 $0.462
24 $155,926
25 $52,393
26 $0.0000
27 -$11,960
28 $0
29 -$12,744
30 -$24,704
31 $66,690
32 4.6
33 $13,472
Oregon
Building>123 West Main StreetFacility Street Address>
Facility City, State, Zip> LaGrande
Total BPA Credit/ Reimbursement
Note: All user supplied input assumptions must be documented through a measurement and verification plan. If the project results in an projected BPA credit/reimbursement of $30,000 or larger, then BPA must accept this measurement and verification plan prior to
project implementation.
Total Proposed Watts of Area Affected by Retrofit
Simple Payback
Unit Value of Gas Heat Interaction (NPV/kWh saved)
Project Life Cycle Cost
Project Benefit/Cost Ratio
Present Value Project/Measure Change in O&M Cost (Savings -$ or Increases +$)
Present Value of Energy Costs
Present Value Life Cycle Lamp Replacement Cost (Savings -$ or Increases +$)
Project-Level Commercial Lighting Retrofit Calculator
This worksheet calculates the annual energy savings and Conservation Rate Credit or Conservation Acquisition Agreement reimbursement resulting from the installation of an energy efficient retrofit lighting, and the project-level economics including savings after HVAC interaction, busbar savings, O&M costs or savings, and periodic lamp replacement costs or savings, PV Life Cycle Cost and TRC B/C ratio.
No data on this sheet may be edited. Enter all data on the Site Audit tab. Inputs here reflect data entered on that tab. Results are shown on lines 12 - 33. Enter data shown below in red into related fields on the Commercial Lighting Retrofits Add-to-Cart page on the PTR site.
INPUTS FROM SITE AUDIT TAB
Total Estimated Annual kWh Site Savings (unadjusted)
Dominant Building Type
Primary Space Heat Fuel Source
Total Floor Area Affected by Project (# of fixtures x 64 sqft/fixture)
Utility Invoice # & Name 20051103 Account #
Present Value of Change in Gas Heating Cost (Savings -$ or Increases +$)
Unit Value of Electric Savings (NPV/kWh)
Annual Energy Cost Savings
Site Lighting Power Density (lpd) Reduction (W/sf)
Present Value of Change in Cleaning/Other O&M Cost (Savings -$ or Increases +$)
Site Unit Energy Savings (kWh/sf)
Present Value Energy Savings
Total Existing Watts of Area Affected by Retrofit
Customer Retail Rate
Measure Life
Default Hours of Lighting Operation for Building Type
Wattage Reduction (%)
RESULTS FOR ADDING PROJECT TO CART
Lighting Savings Yield (HVAC Interaction Adjustment for Building & Space Heat Type)
Annual Site Energy Savings Adjusted for HVAC Interaction (kWh)
Annual Busbar Energy Savings Adjusted for HVAC Interaction (kWh)
Calculator Last Revised> 6/2/2006
Project & Facility Name>
Inferred Weighted Average Hours of Operation (kWh saved/ kW saved)
Todays Date>>>
Project-Level Net PV of Periodic Lamp Replacement Cost (Savings -$ or Increases +$)
Lighting Measure Examples Warehouser, Inc.
Project Cost
Project/Measure Change in Cleaning/Other O&M Cost (Savings -$ or Increases +$)
![Page 8: Using PTR: Lighting Utility Brown Bag Session September 15, 2006](https://reader036.vdocuments.us/reader036/viewer/2022082821/5697bfbd1a28abf838ca1c61/html5/thumbnails/8.jpg)