Page 1: User manual and Installation instructions RIVA …...Lack of burner ignition (no ignition signal from the full seqence ignition device) Ignition gas pressure adjustment Minimum gas

User manual andInstallation instructionsRIVA PLUSModels:

M90D.24SM90D.28SM90D.24SRM90D.28SR

Page 2: User manual and Installation instructions RIVA …...Lack of burner ignition (no ignition signal from the full seqence ignition device) Ignition gas pressure adjustment Minimum gas
Page 3: User manual and Installation instructions RIVA …...Lack of burner ignition (no ignition signal from the full seqence ignition device) Ignition gas pressure adjustment Minimum gas

Congratulations on your choice.Your boiler is electronically controlled and has electronic ignition.The materials it is made of and the control systems it is equipped with give you safety, a highlevel of comfort and energy savings to allow you to get the greatest benefit out of independentheating.

Remember that...n The manualmust be read thoroughly, sothat youwill be able to use the boiler in a safeand sensible way;must be carefully kept. It may be necessaryfor reference in the future.

n First lighting up must be carried out bycompetent and responsible engineer.

n Themanufacturerdisclaimall liability forany translations of the present manual fromwhich incorrect interpretation may occur;cannot be held responsible for non---observ-ance of instructions contained in thismanualor for the consequences of any procedurenot specifically described.

Using the boiler...n Before lighting the boiler, you are ad-vised to have a professionally qualified per-son check that the installation of the gassupply:--- is gas--- tight;--- is of the correct gauge for the flow to theboiler;--- is fitted with all the safety and control de-vices required by the current Regulations;

Ensure that the installer has connected thepressure relief valve outlet to a drain pipe.The manufacturers are not responsible fordamage caused by opening of the pressurerelief valve and consequent escape of water,if not connected correctly to the drain.

n On detecting the smell of gas--- don�t operate any electrical switches, thetelephone or any device that may producesparks;--- open the windows and doors at once tocreate a draught of air which will purge thearea;--- shut off the gas cocks;--- get the assistance of a qualified person.

n Donot touch the appliancewith partsofthe body that are wet or damp and/or barefeet.

n In case of structural work or mainten-ance near the exhaust duct and/or fume ex-haust devices or their attachments, turn offthe appliance. On completion of the work,have a professionally qualified person checktheir efficiency.

n Repairs (under guarantee) must be car-ried out only by an approved engineer, usinggenuine spare parts. Thus do no more thanswitching off the boiler yourself (see the in-structions).

n Your boiler allows heating up of water toa temperature less than boiling point;--- must be connected to a central heatingsystem and/or a hot water supply system,compatible with its performance and output;--- can be used only for those purposes forwhich it has been specially designed;--- must not be touched by children or bythose unfamiliar with its operation;--- must not be exposed to weather condi-tions.

Page 4: User manual and Installation instructions RIVA …...Lack of burner ignition (no ignition signal from the full seqence ignition device) Ignition gas pressure adjustment Minimum gas

Safe handling ofsubstances

Biasi products are manufactured in accordancewith ISO 9000 and do not, and will not, contain anyhazardous materials or substances such as as-bestos, mercury or C.F.C.�s.The appliance packaging does not contain anysubstances,whichmaybe considered a hazard tohealth.

Combustion chamber panelsMaterial: mineral fibersKnown hazards --- Some people can suffer red-dening and itching of the skin. Fibre entry into theeye will cause foreign body irritation, which cancause severe irritation to people wearing contactlenses. Irritation to respiratory tract.Precautions --- Dust goggles will protect eyes.People with a history of skin complaints may beparticularly susceptible to irritation. High dust le-

vels are only likely to arise following harsh ab-rasion. In general, normal handling and use willnot present high risk, follow good hygiene prac-tices,washhandsbefore, touching eyes, consum-ing food, drinking or using the toilet.First aid --- Medical attention must be sought fol-lowing eye contact or prolonged reddening of theskin.

Thermostat / Temperature gaugeDescription --- Sealed phial and capillary contain-ing liquid.Known hazards --- irritating to skin, eyes andthroat. Vapour is harmful. Inflammable --- do notextinguish with water.Precautions --- Do not incinerate. Avoid contactwith broken/leaking phials. Do not purposelypuncture.First aid medical attention must be sought follow-ing eyes/skin contact, wash with clean water.

Appliance category II2H3+ Gas G20 20 mbar, G30 29 mbar, G31 37 mbarCountry of destination: United Kingdom (GB) Irealnd (IE)This appliance conformswith the EEC directive 90/396 and, consequently, it has the right tomakeuseof the brand nameMoreover, theapplianceconformswith theEECdirective87/308 relative to theprevention andelimina-tion of radio disturbances.The appliance is built to comply with the regulation now in force regarding gas appliance�s safety andthe European regulation now in force relative to safety of household and similar electrical appliances.The manufacturer, in the continuous pocess to improve his products, reserves the right to modify thedata expressed in the present documentation at any time and without prior notice.The present documentation is an informative support and it cannot be considered as a contract to-wards third parties.

Page 5: User manual and Installation instructions RIVA …...Lack of burner ignition (no ignition signal from the full seqence ignition device) Ignition gas pressure adjustment Minimum gas

Boiler installation and commissioning tipsn The installation must be carried out bya qualified person whowill be responsible forobserving the current Regulations.

Installing the boiler...n Do not forget to remove the transit capsand plugs from the boiler connections theseare fitted to every boiler.

n Keep the boiler clear of dust during in-stallation and in particular do not allow anydust or debris to enter the top of the boilerwhere the flue connection is made. It is rec-ommended that youput adust sheet over thetop of the boiler until you are ready to makethe flue connection.

n Because every boiler is fired and testedlive at the factory, a small amount of water re-mains within the boiler. It is possible for thiswater to initially cause the pump to seize. It istherefore recommended that the pump rotorbe manually turned to free its rotation beforeturning the boiler on.

n Remember to release the auto air purgebefore filling theboiler. See the instructions toidentify the location of this device.

n Do not remove the cap of the pressuretest points of the air switch (top left side of theboiler).

n You are strongly advised to flush out thesystem both cold and hot in order to removesystem and installation debris.

n It is also sensible to initially fire and com-mission the boiler before connecting any ex-ternal controls such as a room thermostat. Bythis method if you have a subsequent prob-lem following the addition of an external con-trol you can eliminate the boiler from yourfault analysis.

n Do not forget to range rate the boiler tosuit the system requirements. This pro-cedure is covered in the commissioning sec-tion of the installation manual.

n If the boiler is fitted with a digital pro-grammer, when setting the times for auto-matic operation, remember that for every�ON� time theremust bean �OFF� time to fol-low and that on every occasion you enter atime you must also indicate which days thatyou want the boiler to follow the timed set-tings.

n Some products incorporate an anti cycl-ing time delay. It is normal when first switch-ing the boiler on for the boiler to operate onheating for a few seconds then switch off.After 3---4 minutes has elapsed the boiler willthen re ignite and operate perfectly normally.The ignition delay cycle does not preventnormal operation of the boiler to provided.h.w.

n If you are in any doubts as to the installa-tion or operation of the boiler please read theinstruction manuals thoroughly and then ifnecessary contact Biasi UK for advice andassistance.

Please remember that if you are in any doubt about the installation of this product you can contact ourTechnical Helpline on tel. 0121 506 1350

Page 6: User manual and Installation instructions RIVA …...Lack of burner ignition (no ignition signal from the full seqence ignition device) Ignition gas pressure adjustment Minimum gas

TABLE OF CONTENTS

1 Appliance description 1. . . . . . . . . .1.1 Overview 1. . . . . . . . . . . . . . . . . . . . . .1.2 Control panel 1. . . . . . . . . . . . . . . . . .1.3 Isolation valves 1. . . . . . . . . . . . . . . . .1.4 Technical data 1. . . . . . . . . . . . . . . . .1.5 Operation lights 2. . . . . . . . . . . . . . . .

2 Instructions for use 3. . . . . . . . . . . .2.1 Warnings 3. . . . . . . . . . . . . . . . . . . . . .2.2 Refilling procedure 3. . . . . . . . . . . . . .2.3 Ignition 4. . . . . . . . . . . . . . . . . . . . . . . .

2.4 C.h. circuit temperature 4. . . . . . . . . .2.5 D.h.w. temperature (combi) 5. . . . . .2.6 Extinguishing 5. . . . . . . . . . . . . . . . . .2.7 Built in time switch (combi) 6. . . . . . .

3 Useful advice 9. . . . . . . . . . . . . . . . .3.1 Central heating 9. . . . . . . . . . . . . . . . .3.2 Frost protection 9. . . . . . . . . . . . . . . .3.3 Periodic maintenance 9. . . . . . . . . . .3.4 External cleaning 9. . . . . . . . . . . . . . .3.5 Operational faults 9. . . . . . . . . . . . . . .

4 Technical information 11. . . . . . . . . .4.1 Overview 11. . . . . . . . . . . . . . . . . . . . . .4.2 Main diagram M90D.24S M90D.28S 124.3 Main diagram M90D.24SR M90D.28SR 134.4 Technical data M90D.24S, M90D.24SR 144.5 Technical data M90D.28S, M90D.28SR 164.6 Hydraulic specifications 18. . . . . . . . .4.7 Expansion vessel 18. . . . . . . . . . . . . . .

5 General requirements 19. . . . . . . . . .5.1 Related documents 19. . . . . . . . . . . . .5.2 Location of appliance 19. . . . . . . . . . .5.3 Flue system 19. . . . . . . . . . . . . . . . . . . .5.4 Gas supply 20. . . . . . . . . . . . . . . . . . . .5.5 Air supply 20. . . . . . . . . . . . . . . . . . . . .5.6 Ventilation 20. . . . . . . . . . . . . . . . . . . . .5.7 Water circulation (c.h.) 20. . . . . . . . . . .5.8 Domestic water 21. . . . . . . . . . . . . . . . .5.9 Water treatment 21. . . . . . . . . . . . . . . .5.10 Electrical supply 22. . . . . . . . . . . . . . . .

6 Installation 23. . . . . . . . . . . . . . . . . . . .6.1 Warnings 23. . . . . . . . . . . . . . . . . . . . . .6.2 Precautions for installation 23. . . . . . .6.3 Installing the bracket 23. . . . . . . . . . . .

6.4 Overall dimensions 24. . . . . . . . . . . . .6.5 Joints 24. . . . . . . . . . . . . . . . . . . . . . . . .6.6 Mounting the boiler 24. . . . . . . . . . . . .6.7 Fitting the flue system 25. . . . . . . . . . .6.8 Flue restrictors 25. . . . . . . . . . . . . . . . .6.9 Choice of flue 25. . . . . . . . . . . . . . . . . .6.10 Electrical connections 26. . . . . . . . . . .6.11 External frost protection 28. . . . . . . . .6.12 Connecting a M90D.24SR or M90D.28SR

system boiler to a cylinder 28. . . . . . .

7 Commissioning 30. . . . . . . . . . . . . . .7.1 Electrical installation 30. . . . . . . . . . . .7.2 Gas supply installation 30. . . . . . . . . .7.3 Filling the d.h.w. system 30. . . . . . . . .7.4 Initial filling of the system 30. . . . . . . .7.5 Lighting the boiler 31. . . . . . . . . . . . . .7.6 Checking the gas pressure

at the burner 31. . . . . . . . . . . . . . . . . . .7.7 Adjusting the burner ignition 32. . . . .7.8 Adjustment of useful c.h. output 33. .7.9 Checking the ignition device 34. . . . .7.10 Checking the flue system 34. . . . . . . .7.11 Instructing the user 34. . . . . . . . . . . . .

8 Gas conversion 35. . . . . . . . . . . . . . .8.1 Warnings 35. . . . . . . . . . . . . . . . . . . . . .8.2 Procedures 35. . . . . . . . . . . . . . . . . . . .

9 Maintenance 36. . . . . . . . . . . . . . . . . .9.1 Warnings 36. . . . . . . . . . . . . . . . . . . . . .9.2 Dismantling the external panels 36. . .9.3 Emptying the d.h.w. system(combi) 369.4 Emptying the c.h. system 36. . . . . . . .

9.5 Combustion analysis check 37. . . . . .9.6 Cleaning the primary heat exchanger 379.7 Checking the pressurisation in the

expansion vessel 38. . . . . . . . . . . . . . .9.8 Cleaning the burner 38. . . . . . . . . . . . .9.9 Checking the flue 38. . . . . . . . . . . . . . .9.10 Visual inspection of appliance 38. . . .9.11 Gas pressures and soundness 38. . .

Abbreviations used in the manualC.h. = Central heatingD.h.w. = Domestic hot waterD.c.w. = Domestic cold water

Combi = combination boilersmodels M90D.24S, M90D.28SC.h. only = system boilersmodel M90D.24SR, M90D.28SR

USE

INSTALLATION

MAINTENANCE

Page 7: User manual and Installation instructions RIVA …...Lack of burner ignition (no ignition signal from the full seqence ignition device) Ignition gas pressure adjustment Minimum gas

1 APPLIANCE DESCRIPTION

1

1.1 Overview

2

1

3

Fig. 1.1

1 Case front panel2 Control panel3 Control panel cover

1.2 Control panel4 C.h. circuit temperature and pressure gauge5 Time switch (c.h. control) *6 Lock---out signal lamp7 Lockout reset button

8 Function selector and c.h. temperature controlknob

9 D.h.w. temperature control knob *10 Appliance operation lights

1.3 Isolation valves

13 1115 1214Fig. 1.2 (bottom view of the boiler)

11 C.h. return valve12 D.c.w. inlet valve *13 Gas inlet valve14 D.h.w. outlet pipe *15 C.h. flow valve

1.4 Technical dataFor detailed technical data see section 4.4 or 4.5of this manual.

10 89 7 6 45

M90D.24SM90D.28S

M90D.24SRM90D.28SR

Fig. 1.3* not on M90D.24SR and M90D.28SR boilers

USE

Page 8: User manual and Installation instructions RIVA …...Lack of burner ignition (no ignition signal from the full seqence ignition device) Ignition gas pressure adjustment Minimum gas

Appliance operation

2

1.5 Operation lightsThree lights (10 in Fig. 1.3)give detailed indicationregarding the operation of the boiler.The following table gives the relationship betweeneach of the possible light combinations and theirmeaning.

A short pulse every 4seconds:stand---by conditionFunction selector inposition.Anti--- freeze system active1 second pulse every 2seconds: normallyoperating boiler. Functionselector in orposition

C.h. operation

D.h.w. operation *

Frost protect operation

D.h.w. operationExcessive temperature onprimary circuit *Faulty c.h. temperatureprobe NTCFaulty d.h.w temperatureprobe NTC *Faulty primary circuit(no water or absence offlow)Lack of burner ignition (noignition signal from the fullseqence ignition device)Ignition gas pressureadjustmentMinimum gas pressureadjustment

Lamp OFF

Lamp ON

Flashing lamp, alone or simultaneouslywith an other lamp.

Flashing lamp, alternate with anotherlamp.

* not on M90D.24SR and M90D.28SR boilers

USE

Page 9: User manual and Installation instructions RIVA …...Lack of burner ignition (no ignition signal from the full seqence ignition device) Ignition gas pressure adjustment Minimum gas

2 INSTRUCTIONS FOR USE

3

2.1 WarningsBiasi UK Ltd support the Benchmark initiat-ive. The Benchmark Log Book is located atthe back of thismanual and should be com-pleted by the Installing/CommisssioningEngineer and handed over to the User forfuture reference by other visiting En-gineers. Also included is the Service Inter-val Record card that should be completedby the Service Engineer following the an-nual service maintenance of the boiler andsystem.

All CORGI Registered Installers carry aCORGI ID card, and have a registrationnumber. Both should be recorded in yourBenchmark Log Book. You can check yourinstaller is registered by calling CORGI di-rect on 01256 372300.In order to guarantee safety and correct oper-ation, it is essential that all the tests are carriedout by a competent and responsible serviceengineer before lighting up the boiler.The tests are described in the installation in-structions in section 7 commissioning.Ensure that the c.h. circuit is regularly filledwith water (even if the boiler is only used ford.h.w. supply) checking that the pressure indi-cated on the temperature and pressure gauge4 is not lower than that shown in Fig. 2.2.If the pressure reading on the pressure gaugeisbelow that shown in Fig. 2.2, then the systemwill require toppingup.A filling loop isnormallyprovided by the installer for this purpose.

If you are in any doubt regarding this pro-cedure you are advised to contact your In-staller or an Approved Engineer.This appliance is provided with a built in anti---freeze system that operates the boiler whenthe temperature is below 4 ûCTherefore, when the boiler is not lit or used incold weather, with consequent risk of freezingdo not switch off the boiler at the fused spurisolation switch or close the gas inlet cock.When you do not expect to use the boiler for along period and the boiler is not to be used forfrost protection then follow the instructionsgiven in section 2.6 on page 5.

2.2 Refilling procedure1 Isolate the boiler from the electrical supply atthe fused spur. Reconnect the filling loop asdemonstrated in Fig. 2.1.

Temporaryconnection

Control valve

Control valve

Double check valve

Supply pipe(cold water inlet)

C.h. return pipe

Fig. 2.1

2 Open the valves of the filling loop and watchthe gauge until it reaches normal filling pres-sure as shown in Fig. 2.2.

4

Normal fillingpressure

Fig. 2.2

3 Close the valves and remove the filling loop.

If you experience any difficulty with the oper-ation of the boiler, switch off the boiler immedi-ately at the fused spur isolation switch andcontact your Installer or an approved ServiceEngineerAir introduced into the boiler during this filling pro-cess will vent through the automatic air purgerfitted to the boiler. You may also find it necessaryto vent air from your radiator circuit using yourradiator key, however be aware that excessiveventing will cause the pressure in the system todrop.Alwaysensure that thepressuregauge is set at therequired pressure.

USE

Page 10: User manual and Installation instructions RIVA …...Lack of burner ignition (no ignition signal from the full seqence ignition device) Ignition gas pressure adjustment Minimum gas

Instructions for use

4

2.3 Ignition1 Check that the valves located in the lower partof the boiler are open (Fig. 2.3).

Open positionFig. 2.3

2 Turn on the electricity supply to the boiler,switching on the fused spur isolation switch.The appliance operation light 10 (Fig. 2.4) willflash every 4 seconds (stand---by condition).

3 If theboiler is tobe used for c.h. and d.h.wposi-tion the function selector 8 as in Fig. 2.4.(combi) or in Fig. 2.5 (c.h. only).The appliance operation light 10 will flashevery 2 seconds (operating boiler).

810

Fig. 2.4

810

Fig. 2.5

4 If d.h.w. supply only is required (combi), posi-tion the function selector 8 as in Fig. 2.6.

The appliance operation light 10 will flashevery 2 seconds (operating boiler).

810

Fig. 2.6

2.4 C.h. circuit temperatureThe output temperature of c.h. water is adjustablefrom a minimum of about 38°C to a maximum ofabout 85°C (Fig. 2.7), by turning the function se-lector (8).Adjustment of c.h. output on the boiler is auto-matic. The greatest output pre---set in the factorycan, however, be reduced in level according toactual system requirements; this does not affectthe maximum output in d.h.w. operation.Such adjustments must be carried out by a quali-fied person; therefore we advise you to contactyour installer or Service Agent.Adjustment of the boiler temperature alters thegas flow at the burner according to the thermalde-mand in the system. So it isusual to see theburnerlit at the minimum level for more or less longperiods.

Minimum

Maximum

Fig. 2.7

USE

Page 11: User manual and Installation instructions RIVA …...Lack of burner ignition (no ignition signal from the full seqence ignition device) Ignition gas pressure adjustment Minimum gas

Instructions for use

5

AdjustmentIn order to achieve optimal settings for economyand comfort, we recommend adjusting the oper-ating temperature of the c.h. water according tothe outside temperature, positioning the knob asfollows:

Lower than---5 ûC

From 5 to 15 ûC Between---5 and +5 ûC

Fig. 2.8

Your qualified installer will be able to recommendthe most suitable adjustment for your system.The temperature and pressure gauge (4, Fig. 1.3on page 1) will allow you to check that the set tem-perature is obtained.

2.5 D.h.w. temperature (combi)The temperature of the d.h.w. leaving the boilercan be varied from a minimum of about 35°C to amaximum of about 55°C (Fig. 2.9), by turning thetemperature control knob 9.

Minimum

Maximum

9

Fig. 2.9

Adjustment of the d.h.w. temperature is complete-ly separate from that of the c.h. circuit.

The adjustment system integrated within theboiler automatically controls the flow of gas to theburner in order to keep the temperature of d.h.w.delivered constant, between the limits of maxi-mum and minimum output.Where the demand is at a low level or with the tem-perature set to the minimum, it is normal to see acycle of lighting and extinguishing of the burnerwhen running.

AdjustmentIt is advisable to adjust the d.h.w. temperature toa level commensurate with the demand, minimis-ing the need tomix with cold water. In this way, theautomatic control facilities will be fully exploited.Moreover, where the amount of limescale presentin thewater may be particularly great, not exceed-ing the position in Fig. 2.10 of the d.h.w. tempera-ture control knob 9 corresponding to about 50°C(Fig. 2.10), minimises annoying incidences ofscale deposits and clogging.

9

Fig. 2.10

In these cases, however, it is advisable to install asmall water treatment device or softener. Withsuch a device you should avoid periodic descal-ing.Consequently, thed.h.w. heat exchanger will keepits performance consistent for a longer period oftime with resulting gas savings.If the demand for d.h.w. is so great as to preventreaching ahighenough temperature, have theap-propriate output limiting valve installed by your in-staller or an Authorised Service Engineer.

2.6 ExtinguishingTo turn the boiler off set the function selector 8 tothe position shown in Fig. 2.11 (combi) orFig. 2.12 (c.h. only).

USE

Page 12: User manual and Installation instructions RIVA …...Lack of burner ignition (no ignition signal from the full seqence ignition device) Ignition gas pressure adjustment Minimum gas

Instructions for use

6

The appliance operation light 10 will flash every 4seconds.

810

Fig. 2.11

810

Fig. 2.12

Whenyoudonot expect to use the boiler for a longperiod:1 Switch off the electricity supply to the boiler, bymeans of the fused spur isolation switch;

2 Shut off the gas supply cock 13 and the valvesfor the water circuits fitted under the boiler(Fig. 2.13).

3 Empty the water circuits, if necessary, asshown in the installation instructions in the sec-tion maintenance.

Closed position13

Fig. 2.13

2.7 Built in time switch (combi)Thecombiboilersareequippedwith abuilt in elec-tronic time switch (5, Fig. 1.3 on page 1) whichcontrols the c.h. operation.

J

A

BCDEF

G

I

H

Fig. 2.14

Display and control panelA Mode selector switchB Reset buttonC Enter buttonD Increase �+� setting buttonE Decrease �--- � setting buttonF On---off buttonG Day selection buttonsH Day displayI Time displayJ ON---OFF display

Setting the current time and weekdayNote: with a new unit or when the reset button Bhas been pressed, the first day indicator H on theleft and the time display I are flashing.

Set the mode selector switch A to the positionand press the buttons D or E until the current timeappears in the display I.Press the day selection button corresponding tothe current day, considering that button1=Monday, button 2=Tuesday and so on.The clock starts by moving the switch A to theAUTO position.

USE

Page 13: User manual and Installation instructions RIVA …...Lack of burner ignition (no ignition signal from the full seqence ignition device) Ignition gas pressure adjustment Minimum gas

Instructions for use

7

Setting example shown in Fig. 2.15:Current time 16.30, day Thursday.

A

Fig. 2.15

Setting the switching time and day (or days)20memory locationsare available, correspondingto 10 on---off sequences.Set the mode selector switch A to the C1 position.The symbols shown in Fig. 2.16 appears in thedisplay.

A

Fig. 2.16

Press the buttons D or E to set the desired ONtime.Press the buttons G to set the desired day or daysof operation.Press the �enter� button C to confirm the settingand to continue programming the OFF time.Set the OFF time as explained above for the ONsetting and confirmby pressing the �enter� buttonC. Proceed in the same way for other settings.Setting example shown in Fig. 2.17:A --- ON time 7.45, day Monday to Friday.B --- OFF time 10.30, day Monday to Friday.

A BFig. 2.17

Activating the timed settingsSet the mode selector switch A to the AUTO posi-tion shown in Fig. 2.18.

The current time and day appears in the display.TheON---OFF display J indicates the current stateof operation (according to the settings).

A

Fig. 2.18

Note: when the mode selector switch A is in theAUTO position and the boiler is switched off at thefused spur isolation switch, the display J indicatesonly the OFF state. The other indications areblanked.

Reading the timed settingsSet the mode selector switch A to the C1 position.The symbols shown in Fig. 2.16 appears in thedisplay.Press the �enter� button C. Each time the buttonis pressed the display shows the detailsof thenextsetting.Theday displayH givesa flashing indication of theactive day or group of days.

Changing or deleting the timed settingsSet the mode selector switch A to the C1 position.The symbols shown in Fig. 2.16 appears in thedisplay.Press the �enter� button C until the display showsthe setting to be modified or deleted.Theday displayH givesa flashing indication of theactive day or group of days.Press the button (or the buttons)G correspondingto theday (or days) for which it is intended toapplythe modification. The corresponding day displaystops flashing anda newswitching timecan besetor deleted.The time setting can bemodified now by pressingbutton D or E and the operation can be switchedon or off by pressing the button F.Todeletea timeset press the buttonDorE until thesymbols shown in Fig. 2.16 appears in the timedisplay I.The new settigs are memorized by moving theswitch A to a different position.

USE

Page 14: User manual and Installation instructions RIVA …...Lack of burner ignition (no ignition signal from the full seqence ignition device) Ignition gas pressure adjustment Minimum gas

Instructions for use

8

Manual operationThe operation of the time switch can be forced onor off constantly or for a timed period.To force constantly on or off the timer operationset the mode selector switch A to the TIMER posi-tion. The symbols shown in Fig. 2.19 appears onthe display.

Fig. 2.19

The operation can be switched permanently on oroff by pressing the button F and leaving the switchA in the TIMER position.To force a timed delay on or off operation, set themode selector switch A in the TIMER position.Set the time delay by pressing the button D or Eand the operation can be forced on or off by pres-sing the button F.The time delay can be set within the followingranges:1 to 23 hours with steps of 1 hour1 to 27 days with steps of 1 day

The time delay setting is activated by moving theswitch A to the AUTO position.The ON---OFF display J flashes indicating that thecurrent state of operation has been forced.To delete the timed delay setting, set the mode se-lector switch A in the TIMER position, press thebutton D or E until the symbols shown in Fig. 2.19appears in the display and then set the mode se-lector switch A to the AUTO positionSetting example shown in Fig. 2.20:forced ON state for 4 hours.

Fig. 2.20

ResettingTo completely reset the timer, press the reset but-ton with a pointed object (pencil).CAUTION: pushing the reset button will complete-ly erase the settings as well as all the data, includ-ing the current time and day.

USE

Page 15: User manual and Installation instructions RIVA …...Lack of burner ignition (no ignition signal from the full seqence ignition device) Ignition gas pressure adjustment Minimum gas

3 USEFUL ADVICE

9

3.1 Central heatingFor reasonably economical service install a roomthermostat.Never shut off the radiator in the area where theroom thermostat is installed.If a radiator (or a convector) does not heat up,check that no air is present in it and that its valveis open.If the ambient temperature is too high, do not alterthe radiator valves. Reduce the central heatingtemperature instead by means of the room ther-mostat and the function selector (8 in Fig. 3.1).

8

Fig. 3.1

3.2 Frost protectionThis appliance is provided with a built in anti---freeze system that operates the boiler when thetemperature is below 4 ûCTherefore, when the boiler is not lit and used incold weather, with consequent risk of freezing donot switch off the boiler at the fused spur isola-tion switch or close the gas inlet cock.

3.3 Periodic maintenanceFor efficient and continuous operation of theboiler, it is advisable to arrange maintenance andcleaning by an Authorised Service Centre En-gineer, at least once a year.During the service, the most important compo-nents of the boiler will be inspected and cleaned.This service can be part of a maintenance con-tract.In particular, you are advised to have the followingchecks carried out:--- primary heat exchanger;--- domestic hot water heat exchanger;--- burner;--- exhaust fume duct and flue;--- pressurisation of the expansion tank;--- filling up of the central heating circuit;--- bleeding of air from thecentral heating system;

--- general check of the appliance�s operation.

3.4 External cleaningBefore carrying out any cleaning, disconnect theappliance from the electrical mains, using thefused spur isolation switch fitted adjacent to theappliance.To clean the external panels, use a cloth soaked insoapy water. Do not use solvents, abrasive powd-ers or sponges.Do not carry out cleaning of the appliance and/orits parts with readily flammable substances (forexample petrol, alcohols, naphtha, etc.).

3.5 Operational faults

If the lock---out signal lamp comes onthis indicates that the safety lock---out 6 (Fig. 3.2)has stopped the boilerTo re---start the boiler, it is necessary to press theboiler reset button 7 (Fig. 3.2).

7

6

Fig. 3.2

For the first lighting up and followingmaintenanceprocedures for the gas supply, it may be necess-ary to repeat the resetting operation several timesso as to remove the air present in the pipework.

If noises due to air bubbles are heard duringoperation...you should check that the pressure on the tem-perature and pressure gauge (Fig. 2.2 on page 3)is not below the correct setting.If required, top up the system correctly, as de-scribed in the section 2.2 of this manual.Bleed any air present in the radiators, if necessary.

If the pressure on the temperature and pres-sure gauge (4 on page 1) has gone down...it is necessary to top up the appliance with wateragain, so as to raise the pressure to an adequatelevel as described in thesection 2.2of thismanual.If topping up with water has to be done very fre-quently, have the system checked for leaks.

USE

Page 16: User manual and Installation instructions RIVA …...Lack of burner ignition (no ignition signal from the full seqence ignition device) Ignition gas pressure adjustment Minimum gas

Useful advice

10

If water comes out of the pressure relief valveCheck on the temperature and pressure gauge (4on page 1) that the pressure in the central heatingcircuit is not close to 3 bars. In this case, tempera-ture rise in the circuit can cause the pressure reliefvalve to open.So that this does not happen and to decrease thepressure to a normal value, it is advisable to ventsome of the water in the appliance through thebleed valves present in the radiators.

If in time, a reduction in domestic hot watersupply is observed...The likely causes may be impurities caught in thedomestic hot water flow switch filter or limescaledeposited in the domestic hot water heat ex-changer. It is advisable to have the appliancecleaned out by an Authorised Service Centre En-gineer.

If water should occasionally leak from theboiler...

shut off the valves positioned under the boiler(Fig. 2.13 on page 6) and call an Authorised Ser-vice Centre Engineer.

If the left appliance operation light 10 (Fig. 3.3)flashes very quickly the boiler is faulty.

10

Fig. 3.3

In this case or in case of problems other thanthose mentioned here, switch off the boiler, asdescribed in section 2.6 on page 5 and call acompetent and responsible service engineer.

USE

Page 17: User manual and Installation instructions RIVA …...Lack of burner ignition (no ignition signal from the full seqence ignition device) Ignition gas pressure adjustment Minimum gas

4 TECHNICAL INFORMATION

11

4.1 Overview

17

31

30

28

29

24

27

21

35

26

25 1822

34

19 16

32 33

2023Fig. 4.1

11 C.h. return valve12 Domestic cold water inlet valve

13 Gas inlet valve14 D.h.w. outlet pipe15 C.h. flow valve16 D.h.w. temperature probe NTC17 Main circuit drain valve18 C.h. pressure relief valve19 Pump20 Pump vent plug21 Automatic air purger valve22 D.h.w. flow switch23 Modulation gas valve24 Primary circuit flow switch25 C.h. temperature probe NTC26 Three---way diverter valve27 Flame---detecting electrode28 Ignition electrodes29 Burner30 Combustion chamber31 Primary heat exchanger32 Air pressure switch33 Air switch pressure test points34 Fan35 Safety thermostat36 Modulation operator37 Gas valve outlet pressure test point38 Gas valve inlet pressure test point39 D.h.w. heat exchanger40 C.h. expansion tank41 By---pass valve42 Venturi device43 Domestic water circuit filter44 D.h.w. flow limiter45 Flue outlet pipe46 Air intake pipe

INSTALLATION

Page 18: User manual and Installation instructions RIVA …...Lack of burner ignition (no ignition signal from the full seqence ignition device) Ignition gas pressure adjustment Minimum gas

Technical information

12

4.2 Main diagramM90D.24S M90D.28S

42

32

46

45

24

31

28

37

19

18

22

23

38

21

26

39

41

43

11 121513

40

34

27

25

16

14

36

35

29

17

44

Fig. 4.2

INSTALLATION

Page 19: User manual and Installation instructions RIVA …...Lack of burner ignition (no ignition signal from the full seqence ignition device) Ignition gas pressure adjustment Minimum gas

Technical information

13

4.3 Main diagramM90D.24SR M90D.28SR

42

32

46

45

24

31

28

37

19

18

23

38

21

41

11 1513

40

34

27

25

36

35

29

17

Fig. 4.3

INSTALLATION

Page 20: User manual and Installation instructions RIVA …...Lack of burner ignition (no ignition signal from the full seqence ignition device) Ignition gas pressure adjustment Minimum gas

Technical information

14

4.4 Technical dataM90D.24S, M90D.24SR

Nominal heat input kWBTU/h

26,690 754

Minimum heat input kWBTU/h

11,037 530

Maximum useful output kWBTU/h

24,382 906

Minimum useful output kWBTU/h

9,131 047

Central heatingMaximum temperature ûC 85

Minimum temperature ûC 38

Maximum pressure kPabar

2502,5

Minimum pressure kPabar

300,3

Available head(in 1000 l/h)

kPabar

270,27

Domestic hot water (M90D.24S only)Maximum temperature ûC 55

Minimum temperature ûC 35

Maximum pressure kPabar

1 00010

Minimum pressure kPabar

300,3

Flow rate

minimum l/min 2,5

30û rise l/min 11,6*

35û rise l/min 10,0*

40û rise l/min 8,7*

Injectors

Natural G20 130

Butane G30 77

Propane G31 77

Gas supply pressuresGas norm. min max

NaturalG20

Pambar

2 00020

1 70017

2 50025

ButaneG30

Pambar

2 90029

2 00020

3 50035

PropaneG31

Pambar

3 70037

2 50025

4 50045

Gas pressures at the burnerGas min max Ignition

NaturalG20

Pambar

1801,8

1 17011,7

6006,0

ButaneG30

Pambar

5005,0

2 76027,6

1 20012

PropaneG31

Pambar

6106,1

3 57035,7

1 30013

Gas rateGas min max

NaturalG20

m3/h 1,16 2,82

ButaneG30

kg/h 0,87 2,09

PropaneG31

kg/h 0,85 2,06

* calculated values subject to toleranceNet calorific value at 15 ûC and 1013,25 mbarG 20 34,02 MJ/m3G 30 45,6 MJ/kgG 31 46,4 MJ/kg1 mbar approximately equals 10 mm H2O

INSTALLATION

Page 21: User manual and Installation instructions RIVA …...Lack of burner ignition (no ignition signal from the full seqence ignition device) Ignition gas pressure adjustment Minimum gas

Technical information

15

Electrical Data

Voltage V~ 230

Frequency Hz 50

Power consumption W 150

Protection degree IPX4D

External fuse rating A 3

Internal fuse rating A 1,6 T

Flue design

Flue pipe diameter

Coaxial mm 60/100

Twin split pipes mm 80

Roof mm 80/125

Nominal heat flow rate* kW 26,6

Exhaust temperature* ûC 145

Smoke production* kg/h 55,1

Flue gas figures

Nominal heat input* kW 26.6

CO2 content % 7,0

O2 content % 8,4

CO content ppm 150

Exhaust temperature* ûC 145

Other specifications

Height mm 703

Width mm 400

Depth mm 325

Weight (dry) kg 37

Water volume in the boler(up to 1 bar)

l (kg) 1,0

* Values refer to tests with a 1 m chimney working at the nominal heat input

INSTALLATION

Page 22: User manual and Installation instructions RIVA …...Lack of burner ignition (no ignition signal from the full seqence ignition device) Ignition gas pressure adjustment Minimum gas

Technical information

16

4.5 Technical dataM90D.28S, M90D.28SR

Nominal heat input kWBTU/h

31,1106 107

Minimum heat input kWBTU/h

13,044 353

Maximum useful output kWBTU/h

28,496 895

Minimum useful output kWBTU/h

10,836 847

Central heatingMaximum temperature ûC 85

Minimum temperature ûC 38

Maximum pressure kPabar

2502,5

Minimum pressure kPabar

300,3

Available head(in 1000 l/h)

kPabar

270,27

Domestic hot water (M90D.28S only)

Maximum temperature ûC 55

Minimum temperature ûC 35

Maximum pressure kPabar

1 00010

Minimum pressure kPabar

300,3

Flow rate

minimum l/min 2,5

30û rise l/min 13,6*

35û rise l/min 11,6*

40û rise l/min 10,2*

InjectorsNatural G20 130

Butane G30 77

Propane G31 77

Gas supply pressures

Gas norm. min max

NaturalG20

Pambar

2 00020

1 70017

2 50025

ButaneG30

Pambar

2 90029

2 00020

3 50035

PropaneG31

Pambar

3 70037

2 50025

4 50045

Gas pressures at the burner

Gas min max Ignition

NaturalG20

Pambar

1801,8

1 17011,7

6006,0

ButaneG30

Pambar

4504,5

2 76027,6

1 20012

PropaneG31

Pambar

5705,7

3 57035,7

1 30013

Gas rate

Gas min max

NaturalG20

m3/h 1,37 3,29

ButaneG30

kg/h 1,02 2,45

PropaneG31

kg/h 1,00 2,41

Electrical Data

Voltage V~ 230

Frequency Hz 50

Power consumption W 170

Protection degree IPX4D

External fuse rating A 3

Internal fuse rating A 1,6 T

* calculated values subject to toleranceFor the net calorific values of G20, G30, G31 see the technical data at page 141 mbar approximately equals 10 mm H2O

INSTALLATION

Page 23: User manual and Installation instructions RIVA …...Lack of burner ignition (no ignition signal from the full seqence ignition device) Ignition gas pressure adjustment Minimum gas

Technical information

17

Flue design

Flue pipe diameter

Coaxial mm 60/100

Twin split pipes mm 80

Roof mm 80/125

Nominal heat flow rate* kW 31,1

Exhaust temperature* ûC 165

Smoke production* kg/h 70,6

Flue gas figuresNominal heat input* kW 31,1

CO2 content % 6,3

O2 content % 9,7

CO content ppm <100

Exhaust temperature* ûC 165

Other specifications

Height mm 703

Width mm 400

Depth mm 325

Weight (dry) kg 39

Water volume in the boler(up to 1 bar)

l (kg) 1,1

* Values refer to tests with a 1 m chimney working at the nominal heat input

INSTALLATION

Page 24: User manual and Installation instructions RIVA …...Lack of burner ignition (no ignition signal from the full seqence ignition device) Ignition gas pressure adjustment Minimum gas

Technical information

18

4.6 Hydraulic specifications

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0 200 400 600 800 1000 1200 1400

0

10

20

30

40

kPa bar

l/h

60

50

Fig. 4.4

The hydraulic specifications in Fig. 4.4 representthe pressure (available head for the central heat-ing system) as a function of the flow rate.The load loss due to the boiler has already beensubtracted.

Output with thermostat cocks shut offThe boiler is fitted with an automatic by---passvalve (41 on page 11), which protects the primaryheat exchanger.In case of excessive reduction or total blockage ofwater circulation in the central heating systemowing to closure of the thermostatic valves or sys-

tem component cocks, the by---pass valve ensur-es a minimum flow of water through the primaryheat exchanger.

4.7 Expansion vessel

Note: this boiler is designed for operation onlyin a sealed central heating systemThe height difference between the pressure reliefvalve and the highest point in the system may be7m at most.For greater differences, increase the pre--- loadpressure in the expansion vessel (40 on page 11)and the system, when cold, by 0.1 bar for eachadditional 1m.

Capacity l 7,0

Pre--- load pressure kPabar

1001,0

Maximum volume of waterin the system * l 154

Tab. 4.1

* Where conditions are:--- Average maximum temperature of the systemis 80°C

--- Initial temperature when filling up the system is10°C

For systems with volumes greater than 154l, anadditional expansion vessel must be provided.

INSTALLATION

Page 25: User manual and Installation instructions RIVA …...Lack of burner ignition (no ignition signal from the full seqence ignition device) Ignition gas pressure adjustment Minimum gas

5 GENERAL REQUIREMENTS

rev. 17.09.9319

Biasi UK Ltd support the Benchmark initiative.TheBenchmarkLogBook is locatedat thebackof this manual and should be completed by theInstalling/Commisssioning Engineer andhandedover to theUser for future reference byother visiting Engineers. Also included is theService Interval Record card that should becompleted by the Service Engineer followingthe annual service maintenance of the boilerand system.

For Ireland (IE), it is necessary to complete a�Declaration of Conformity� to indicate com-pliance to I.S.813.2002.

This appliance must be installed by a compet-ent person in accordance with the Gas Safety(installation & Use) Regulations.

5.1 Related documentsThe installation of this appliance must be in ac-cordance with the relevant requirements of thecurrent Gas Safety (Installation & Use) Regula-tions, the Local Building Regulations, the currentI.E.E. Wiring Regulations, the Regulations andby--- laws of the local water undertaking, and inScotland, in accordance with the Building Stan-dards (Scotland) Regulation. Health and safetydocument nû 635 �Electricity at work regs.�.It should also be in accordance with the BritishStandard Codes of Practice.In Ireland (IE). The installation must be carried outby a Competent Person and installed in accord-ance with the current edition of I.S.813.2002 �Do-mestic Gas Installations� the current BuildingRegulations and reference should be made to thecurrent ETCI rules for electrical installations.

5.2 Location of applianceThe appliance may be installed in any room or in-ternal space, although particular attention isdrawn to the requirementsof thecurrent I.E.E.Wir-ing Regulations, and in Scotland, the electricalprovisions of the Building Regulations applicablein Scotland, with respect to the installation of the

combined appliance in a room containing a bathor shower.For Ireland (IE), reference should be made to thecurrent edition of I.S.813.2002 and the currentETCI rules for electrical installations.

Where a room---sealed appliance is installed ina roomcontainingabath or shower, any electri-cal switch or appliance control, utilisingmainselectricity should be so situated that it cannotbe touched by a person using the bath orshower.The location must permit the provision of an ad-equate flue and termination.For unusual locations special procedures may benecessary and BS 6798 gives detailed guidanceon this aspect.A compartment used to enclose the appliancemust be designed specifically for this purpose.This appliance is not suitable for external installa-tion.

5.3 Flue systemTheprovision for satisfactory flue terminationmustbe made as described in BS 5440 part 1.For Ireland (IE), refer to I.S.813.2002.Theappliancemustbe installed so that the flue ter-minal is exposed to external air.It must not be installed so that the terminal dis-charges into an other room or space as an out-house or lean--- to. It is important that the positionof the terminal allows a free passage of air acrossat all times.The terminal should be locatedwithdue regard forthe damage or discoloration that might occur tobuilding products in the vicinity.In cold and/or humid weather water vapour maycondense on leaving the flue terminal; the effect ofsuch �steaming� must be considered.

INSTALLATION

Page 26: User manual and Installation instructions RIVA …...Lack of burner ignition (no ignition signal from the full seqence ignition device) Ignition gas pressure adjustment Minimum gas

General requirements

rev. 17.09.9320

The minimum acceptable spacing from the ter-minal to obstructions and ventilation openings arespecified in Fig. 5.1.

A

BC

D

E

F

G

IJ K

LM

G

H

N

O

Fig. 5.1Terminal position mm

A Directly below a window or other opening 300. . . .B Below gutters, soil pipes or drain pipes 75. . . . . .C Below eaves 200. . . . . . . . . . . . . . . . . . . . . . . . . . . . .D Below balconies or car port roof 200*. . . . . . . . . . .E From vertical drain pipes and soil pipes 75. . . . . .F From internal corners 150*. . . . . . . . . . . . . . . . . . . .G From external corners 75*. . . . . . . . . . . . . . . . . . . . .H Above ground or balcony level 300. . . . . . . . . . . . .I From a surface facing a terminal 600. . . . . . . . . . . . .J From a terminal facing a terminal 1 200. . . . . . . . . .K From an opening in the car port.

(e.g. door, window) into dwelling 1 200. . . . . . . . .L Vertically from a terminal in the same wall 1 500. .M Horizontally from a terminal in the same wall 300.N Above the roof pitch with roof slope less.

than or equal to 30û 350. . . . . . . . . . . . . . . . . . . . . .Above the roof pitch with roof slopemore than 30û 600. . . . . . . . . . . . . . . . . . . . . . . . . . .

O From wall face 600. . . . . . . . . . . . . . . . . . . . . . . . . . .* specific manufacturer requirements

5.4 Gas supplyTheGasmeter is connected to the service pipe bythe local gas region or a local gas region contrac-tor.If the gas supply for the boiler serves otherappliances ensure that an adequate supply isavailable both to the boiler and the otherappliance when they are in use at the same time.Pipework must be of adequate size. Pipes of asmaller size than the boiler inlet connection shouldnot be used.

Installation pipes should be fitted in accordancewith BS 6891 and the complete installation shouldbe tested for soundness.For Ireland (IE), refer to I.S.813.2002.

5.5 Air supplyThe room in which the boiler is installed does notrequire a purpose provided air vent.

5.6 VentilationIf installed in a cupboard or compartment, it is notnecessary to provide additional ventilation forcooling for this particular product. However con-sideration must be given to clearance require-ments for maintenance (see section 6.2) andundernocircumstancesmust stored articles beal-lowed to come into contact with the boiler or fluepipe.

5.7 Water circulation (c.h.)Detailed recommendations are given in BS 6798and BS 5449; the following notes are given forgeneral guidance.For Ireland (IE), refer to I.S.813.2002.

PipeworkCopper tubing to BSEN 1057 is recommended forwater pipes. Jointing should be either with capil-lary soldered or with compression fittings.Where possible pipes should have a gradient toensure air is carried naturally to air release pointsand water flows naturally to drain taps.The appliance has a built--- in automatic air releasevalve, it should be ensured as far as possible thatthe appliance heat exchanger is not a natural col-lecting point for air.Except where providing useful heat, pipes shouldbe insulated to prevent heat loss and to avoidfreezing.Particular attention should be paid to pipes pas-sing through ventilated spaces in roofs and underfloors.

By---passThe appliance includes an automatic by---passvalve which protects the main heat exchanger incase of reduced or interrupted water circulation

INSTALLATION

Page 27: User manual and Installation instructions RIVA …...Lack of burner ignition (no ignition signal from the full seqence ignition device) Ignition gas pressure adjustment Minimum gas

General requirements

rev. 17.09.9321

through the heating system due to the closing ofthermostatic valvesor cock--- type valveswithin thesystem.The by---pass is calibrated to assure a minimumflow of 500---600 lts/hr through the main heat ex-changer.If you are installing a system that includes thermo-static radiator valves (TRV) and/or small bore(8---10 mm) it may be necessary to fit an externalby---pass to facilitate correct operation of theboiler.

Air release pointsThesemust be fitted at all high pointswhere airwillnatural collect and must be sited to facilitate com-plete filling of the system.

Expansion vesselThe appliance has an integral sealed expansionvessel to accommodate the increase of water vol-ume when the system is heated.Refer to Tab. 4.1 on page 18 for its technical data.If the heating circuit has an unusually high watercontent, calculate the total expansion and add anadditional sealed expansion vessel with adequatecapacity.

Mains water feed: central heatingThere must be no direct connection to the mainswater supply even through a non return valve,without the approval of the Local Water Authority.

Mains water feed: hot water supplyThe domestic section of the boiler is designed towithstand an internal domestic water pressure of10 bar. Where it is likely that the mains domesticwater pressure may exceed 5 bar, it is possibledue to internal �water hammer� effects that thepressure within the domestic system can increaseto a level in excess of the 10 bar limit.In these circumstances it is therefore recom-mended that a 3 bar pressure reducing valve befitted to the incoming mains water supply and amini expansion vessel installed on the domesticcircuit.These devices will protect the boiler and the do-mestic system from damage due to excessive do-mestic water pressure.

FillingA method for initially filling the system and replac-ing water lost during servicing must be provided

and itmust comply with local water authority regu-lations.The correct method is shown in Fig. 5.2.

The temporary connection must be removedimmediately after filling.

Temporaryconnection

Control valve

Control valve

Double check valve

Supply pipe(cold water inlet)

C.h. return pipe

Fig. 5.2

The installer should ensure that no leaks existeither inside the boiler or on the system as fre-quent filling of the system could cause prematurescaling of the heat exchanger.

5.8 Domestic waterThe domesticwater installationmust be in accord-ance with the relevant recommendations of BS5546. Copper tubing to BS EN 1057 is recom-mended for water carrying pipework and must beuse for pipework carrying potable water.For Ireland (IE), refer to I.S.813.2002.

5.9 Water treatment

Central heating circuitWhere a new boiler is fitted to a new system witheither plastic or copper pipes, it is important thesystem is fully flushed, on completion, to ensureflux residues, swarfs, oils and other installation de-bris is removed.Where a new boiler is fitted to an existing system,it is important the debris from the existing systemis fully removed in order to ensure the efficiency ofthe new appliance is maintained.Details on flushing procedure are given in the sec-tion 7.4 of this manual.

Domestic hot water circuit (scale protection)In areas where the water is �hard� (i.e. more than200 ppm total hardness as defined by BS 7593:

INSTALLATION

Page 28: User manual and Installation instructions RIVA …...Lack of burner ignition (no ignition signal from the full seqence ignition device) Ignition gas pressure adjustment Minimum gas

General requirements

rev. 17.09.9322

1993 Table 2) it is recommended that aproprietaryscale--- reducing device is fitted into the boiler coldsupply, within the requirements of the local watercompany.

5.10 Electrical supply

Warning, this appliance must be earthed.External wiring to the appliance must be carriedout by a competent person and be in accordancewith the current I.E.E. Regulations and any localregulations which apply.Reference should be made tu the current ETCIrules for electrical installations.For Ireland (IE), refer to I.S.813.2002.

The boiler is supplied for connection to a 230 V~50 Hz supply. The supply must be fused at 3A.Themethod of connection to the electricity supplymust facilitate complete electrical isolation of theappliance by the use of a fused double pole isola-tor having a contact separation of at least 3 mmbetween poles or alternatively, by the use of a 3Afused three pin plug and unswitched shutteredsocket outlet both complying with BS 1363.The point of connection to the electricity supplymust be readily accessible and adjacent to theappliance exceptwere the appliance is installed ina bathroom this must then be sited outside thebathroom.

INSTALLATION

Page 29: User manual and Installation instructions RIVA …...Lack of burner ignition (no ignition signal from the full seqence ignition device) Ignition gas pressure adjustment Minimum gas

6 INSTALLATION

23

6.1 WarningsThe use of gas appliances is subject tostatutory control; it is essential to observethe current regulations and laws in force(see also chapter 5).The appliance must discharge combustionproducts directly outside or into a suitable ex-haust duct designed for this purpose.Combustion products must be dischargedusing original flue kits only, since they are inte-gral parts of the boiler.For LPG, the appliance must also conformwiththe requirements of the distributors and com-ply with current Regulations and laws in force.The safety relief valve must be connected to asuitable drain, or discharge in a safe manner.The electrical wiring must conformwith currentRegulations, in particular:--- theboilermustbe earthedusing thecorrectbonding clamp.

--- Adjacent to the boiler a fused spur isolationswitch must be installed which permits acomplete switching off in the conditions ofthe overvoltage category III. Refer to sec-tion 6.10 in this chapter for the electricalconnections.

In no circumstances will the manufacturerbe held responsible if the warnings and in-structionscontained in thismanual havenotbeen complied with.

6.2 Precautions for installationFor the installation proceed as follows:--- The boiler must be fixed to a strong wall.--- The dimensions for the exhaust fume duct de-tailed in section6.7 and the correctproceduresfor installing the duct, depicted in the instruc-tion leaflet included with the flue kit, must becomplied with during installation.

--- To allow maintenance procedures it is necess-ary to leave the minimum gaps indicated inFig. 6.1.

25 50

250

200

Fig. 6.1 (all dimensions in mm)

--- When installing the boiler in a cupboard, coveror alcove allow at least50mmpermanentclear-ance from the front face of the boiler. Also en-sure sufficient clearance to allow free accessfor servicing and the lowering of the front con-trol panel.

--- If the boiler is installed outside, cover the ap-pliance to protect it against the elements andadd some special anti--- freeze (neutralised) tothe c.h. system.

--- Before installing the boiler on an existing c.h.system, flush it out thoroughly before fitting theboiler, so as to remove muddy deposits.

--- It is advisable to equip the system with a sedi-ment filter, or use awater--- treatment product inthe circulating water.The latter option in particular, not only cleansout the system, but also has an anti---corrosiveeffect by promoting formation of a protectiveskin on metal surfaces and neutralising gasespresent in the water.We recommend the use of a suitable universalinhibitory to protect the c.h. system from cor-rosion.

6.3 Installing the bracketPrecautionsBefore mounting the bracket, check that the di-mensions for fitting the exhaust fume duct arecomplied with (refer to the leaflet included with theflue kit, packed separately).

INSTALLATION

Page 30: User manual and Installation instructions RIVA …...Lack of burner ignition (no ignition signal from the full seqence ignition device) Ignition gas pressure adjustment Minimum gas

Installation

24

Utilise the paper template supplied with the boilerto determine the fixing position for the bracketandboiler. Securely mount the bracket to the wallusing appropriate fixings suitable for the type ofwall construction and capable of supporting thetotal (wet) load. Refer to the weight given in thetechnical data tables specific for each model.

6.4 Overall dimensions

400

65645265

85 255

703

561

20

193

250

95

83

35 165

101

20

B

Wallmountingbracket

Gas

D.h.w.

C.h.

Cold

C.h. returnflow

outlet*

waterinlet *

A --- air intake/flue outlet pipe ø 100 (co--- axial)

A

C

B --- flue outlet pipe ø 80 (twin kit)C --- air intake pipe ø 80 mm (twin kit)

325

147

237C

A and B

* not present on c.h. only boilers

Fig. 6.2 (all dimensions in mm)

6.5 Joints

Functions Pipe sizesGas, c.h. return, c.h. flow ø 22D.c.w. inlet * ø 15D.h.w. outlet * ø 15Pressure relief valve ø 15* not present on M90D.24SR and M90D.28SRmodels

Tab. 6.1 (sizes in mm o.d.)

6.6 Mounting the boiler1 Take the protective caps off the boiler pipe-work.

2 Thoroughly clean the connections.3 Mount the boiler on its bracket.4 Fix the c.h. valves A and gas cock B (¾�) to theboiler using the ¾� gaskets (Fig. 6.3)

5 Fix the ø 22mmpipes C (c.h. circuit) to the c.h.valves A and the ø 22 mm pipe D (gas) to thecock B using the ¾� gaskets.

6 Repeat the above procedure for the d.c.w. inletutilising the½� cold water inlet valve E, the ø 15mm copper tail F with its connection nut andtwo ½� gaskets.

7 Fix the ø 15 mm copper tail G with the ½� con-nection nut and a ½� gasket.

8 Connect the pipe H (Fig. 6.4) from the pres-sure relief valve to the safety discharge pipe-work.

C

A

A

B

D

C

E

FG

Fig. 6.3

H

Fig. 6.4

INSTALLATION

Page 31: User manual and Installation instructions RIVA …...Lack of burner ignition (no ignition signal from the full seqence ignition device) Ignition gas pressure adjustment Minimum gas

Installation

25

6.7 Fitting the flue systemRefer to the assembly instructions containedwith-in the chosen flue kit packaging for the correct as-sembly and installation.

6.8 Flue restrictors

Two restrictors with different size are suppliedwith the boilers.A 44 mm size is fitted to the boiler and a 47 mmsize is supplied in a separate bag.For the correct use of the restrictorswithco---axialpipes ø 60/100 mm refer to Tab. 6.2.For the correct use of the restrictors with verticalroof kit ø 80/125 mm refer to Tab. 6.3.For the correct use of the restrictors with twinpipes refer to Fig. 6.8.

Equivalent length (ø 60/100) Restrictor

Between 0,3 and 1 m ø 44 mm

More than 1 m up to 2 m ø 47 mm

More than 2 m up to 4 m no restrictor

Tab. 6.2 FOR CO---AXIAL STANDARD FLUE

Equivalent length (ø 80/125) Restrictor

Between 0,5 and 1,5 m ø 44 mm

More than 1,5 m up to 6,5 m ø 47 mm

More than 6,5 m up to 8,5 m no restrictor

Tab. 6.3 FOR VERTICAL ROOF KIT

The appropriate restrictor, when necessary, mustbe fitted in the flue outlet elbow as indicated inFig. 6.5.

Fig. 6.5

6.9 Choice of flueThe following flue kits are available for connectingto the boiler:

Standard horizontal flue kit (Fig. 6.6A)Co---axial 60/100mm --- nominal length 1mThiskit is normally suppliedwith theboiler and canbe fitted to allow discharge to the rear or eitherside of the boiler via the flanged boiler adapterelbow. Minimum length required is 0.3 m. Maxi-mum equivalent length of 4 metres can beachieved utilising extensions. This flue systemcanonly be used to discharge horizontally, it is not de-signed to enable termination in the vertical plane.

Vertical kit with 90û elbow (Fig. 6.6B)Co---axial 60/100 mmSupplied with a straight flanged adapter a co---axial elbow and a co---axial pipe with terminal, thiskit allows for a vertical rise of 0,5 m from the boiler.In all circumstances the flue terminal must dis-charge horizontally and the equivalent flue lengthmust not exceed 4 metres.

Elbows 45û & 90û (Fig. 6.6C)Co---axial 60/100mm.Elbow kits enable the standard flue kits to beoffsetto overcome obstructions or ensure the correctclearances for the flue terminal. Each elbow usedin addition to the standard flanged elbow reducesthe overall acceptable length of the flue systemasfollows:45û reduce length by 0.5 m.90û reduce length by 1 m.

ø 60/100

ø 60/100

90û=---1 m

45û=---0,5 m

A

B

C

Min = 0,3 mMax = 4 m

Fig. 6.6

INSTALLATION

Page 32: User manual and Installation instructions RIVA …...Lack of burner ignition (no ignition signal from the full seqence ignition device) Ignition gas pressure adjustment Minimum gas

Installation

26

Twin pipe kits ø 80 mm (Fig. 6.7)Various twin (split) pipes kits and optional acces-sories (elbows) are available to assist in the ter-mination of the flue where the boiler is installed ina location remote to an outside wall.These kits allow for separation of the air supplypipe from the pipe that discharges the exhaustgasses. Consequently it is possible to extend theflue system to a greater distance than that pro-vided by the standard horizontal co---axial flue.If either an additional 45û or 90û accessory elbowis used then the maximum permissible length ofeither pipe must be reduced by 0.90 m or 2,75 mrespectively.

90û=---2,75 m

45û=---0,90 m

Fig. 6.7

The graph in Fig. 6.8 demonstrates the allowableequivalent lengths for the air supply and flue ex-haust pipes.

02468101214161820222426283032

0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32

Restrictor47 mm

NoRestrictor

Allowed values

Flue exhaust �a�

Air intake �b�

Fig. 6.8 (all dimensions in metres)

Vertical--- roof kit (Fig. 6.9)This kit allows vertical termination of the flue pipethrough the roof. The kit is 1.2 m in length. Exten-sion pieces (Co---axial) are also available which al-lows the flue system to be extended to a totaloverall maximum permissible length.

Optional 45û and90û elbowscan beused tooffsetthe flue route.

max = 8.5 m

Fig. 6.9

Vertical flue kit --- condensationWhen fitting the 80/125 l flue kits where the Equiv-alent Flue Length exceeds 3 m a condensate col-lector and syphon are required.If the appliance normally operates at minimumoutput power at very low temperatures (e.g. 40 ûCreturn / 60 ûC flow), the above equivalent lengthshould be reduced to 1 m.The syphon must also be connected to a suitabledrain.Please, see the boiler accessory leaflet availablefrom your Supplier for details or contact Biasi UKTechnical Helpline.

6.10 Electrical connections

Connection to the electricity supply1 Remove the front panel of the case (see thesection 9.2 in this manual).

2 Remove the screws I and J (Fig. 6.10).3 Loosen the screws K.

INSTALLATION

Page 33: User manual and Installation instructions RIVA …...Lack of burner ignition (no ignition signal from the full seqence ignition device) Ignition gas pressure adjustment Minimum gas

Installation

27

J

KJK

I

I

Fig. 6.10

4 Remove the side panels ormove the lower partof the side panels as indicated in Fig. 6.11 andpull the control panel.When completely pulled out, the panel can ro-tate 45û downwards to facilitate the operationson the internal parts.

Fig. 6.11

5 Loosen the screws L and remove the servicepanel (Fig. 6.12).

L

Fig. 6.12

For the electrical connection to the boiler use elec-tricwireswhich conform to the current regulations,with flexible cord, each core having a cross sec-tion area not less than 0,75 mm2.6 Connect the electrical supply flexible cordcoming from the fused spur isolation switch tothe power supply terminal block of the boiler(Fig. 6.13) keeping the same connections forthe live (brown wire) and the neutral (bluewire). External 3 A fuseor fusedplugwith samecurrent rating is recommended.Do not connect live wires to terminals towhich the room thermostat must be con-nected.

7 Connect the earth wire (yellow/green).

Connection of a room thermostatThe room thermostat must be connected to theterminal block situated next to the control panel.

When connecting any type of external control,the link M in Fig. 6.13 must be removed.

INSTALLATION

Page 34: User manual and Installation instructions RIVA …...Lack of burner ignition (no ignition signal from the full seqence ignition device) Ignition gas pressure adjustment Minimum gas

Installation

28

12

L N

3

To fused spurisolation switch

Power supplyterminal block

External controlsterminal block

M

Fig. 6.13

8 Connect the room thermostat between ter-minals 1 and 3 as shown in Fig. 6.14.Do not connect live wires to terminals towhich the room thermostat must be con-nected.

Power supplyterminal block

External controlsterminal block

T

Room thermostat

12

L N

3

Fig. 6.14

9 Route the electrical supply flexible cord andthe external control flexible cord as illustratedin Fig. 6.15.Lock the flexible cords in place with the flexiblecord clamps

To the fused spurTo the externalcontrol device

isolation switch

Fig. 6.15

6.11 External frost protection10 Connect the frost thermostat between ter-minals 1 and 2 as shown in Fig. 6.16.Do not connect live wires to terminals towhich the room thermostat must be con-nected.

Power supplyterminal block

External controlsterminal block

T

Room thermostat

T

Frost thermostat

12

L N

3

Fig. 6.16

6.12 Connecting a M90D.24SR orM90D.28SR system boiler toa cylinder

Two schematic wiring diagrams are given in thissection showing two possible ways to connect anexternal programmer to a mid---position divertervalve to provide independent timed and thermo-static control of heating and hot water.In both diagrams the earth wires are not shown forclarity. Earth wiring must be fitted as necessary.

INSTALLATION

Page 35: User manual and Installation instructions RIVA …...Lack of burner ignition (no ignition signal from the full seqence ignition device) Ignition gas pressure adjustment Minimum gas

Installation

29

BLGRBROR

Valve colour keyBR --- BrownBL --- BlueGR --- GreyOR --- Orange

MAINS230V a.c.Switched 3 Amp fused,spur

Programmer

Room thermostat

Cylinderthermostat

Mid---positiondiverter valve

Relay

L

N

Remove roomthermostat link

M90D.24SRM90D.28SRExternal controlterminal block

Power supplyterminal block

L N

321

Fig. 6.17 --- relay controlled boiler

BLGRBROR

Valve colour keyBR --- BrownBL --- BlueGR --- GreyOR --- Orange

MAINS230V a.c.Switched 3 Amp fused,spur

Programmer

Room thermostat

Cylinderthermostat

Mid---positiondiverter valve

L

N

Do notremove roomthermostat link

M90D.24SRM90D.28SRExternal controlterminal block

Power supplyterminal block

L N

321

Fig. 6.18 --- directly controlled boiler

INSTALLATION

Page 36: User manual and Installation instructions RIVA …...Lack of burner ignition (no ignition signal from the full seqence ignition device) Ignition gas pressure adjustment Minimum gas

7 COMMISSIONING

30

Ensure that the Benchmark Log Book is satis-factorily commpleted during the commssion-ingprocess. TheLogBook is locatedat theendof this manual. This manual should be handedto theUser following completion of the installa-tion and commissioning process. Failure tocomply with these requirments may invalidatethe manufacturers guarantee.

For Ireland (IE), it is necessary to complete a�Declaration of Conformity� to indicate com-pliance to I.S.813.2002.

7.1 Electrical installationPreliminary electrical system checks to ensureelectrical safety shall be carried out by a compet-ent person. i.e. polarity, earth continuity, resis-tance to earth and short circuit.If a fault has occurred on the appliance the fault find-ing procedure should be followed as specified in theservice manual.

7.2 Gas supply installation1 Inspect the entire installation including the gasmeter, test for soundness and purge, all as de-scribed in BS 6891.

For Ireland (IE), refer to I.S.813.2002.2 Open the gas cock 13 (Fig. 7.1) on theappliance and check the gas connector on theappliance for leaks.

Open position13 12Fig. 7.1

7.3 Filling the d.h.w. system1 Close all hot water draw---off taps.2 Open the cold water inlet valve 12 (Fig. 7.1).

3 Slowly open each draw---off tap and close itonly when clear water, free of bubbles, flowsout.

7.4 Initial filling of the system1 Open the c.h. flow and return valves.2 Remove the front panel of the case (see thesection 9.2 in this manual.

3 Unscrew the cap on the automatic air purger-valve 21 (Fig. 7.2) one full turn and leave openpermanently.

4 Gradually open stopcock at the filling pointconnection to the c.h. system until water isheard to flow; do not open fully.

21

20

Fig. 7.2

5 Open each radiator air vent starting at thelowest point of the system and close it onlywhen clear water, free of bubbles, flows out.

6 Purge theair from the pumpby unscrewing thepump plug 20 (Fig. 7.2); release the pumpshaft by turning in the direction indicated bythe arrow on the information plate.

7 Replace the pump plug.8 Continue filling the system. The actual readingshould ideally be 1,3 bar and not less than 0,3bar.

9 Close all air release valves on the c.h. system.10 Inspect the boiler and the system for watersoundness and remedy any leaks discovered.

INSTALLATION

Page 37: User manual and Installation instructions RIVA …...Lack of burner ignition (no ignition signal from the full seqence ignition device) Ignition gas pressure adjustment Minimum gas

Commissioning

31

11 Cold flush the system to remove any loose par-ticlesandany systemdebrisbefore starting theboiler for the first time

The flushing procedure must be in line withBS7593 Treatment of Water in d.h.w. c.h. Sys-tems.

When the installation and second filling arecompleted turn on the c.h. system and run ituntil the temperature has reached the boileroperating temperature. The system must thenbe immediately flushed through.

This procedure must be repeated twice more.

During this operation we highly recommendthe use of a c.h. flushing detergent in the quan-tities as specified by the appropriate manufac-turer, whose function it is to dissolve anyforeign matter which may be in the system.

The above operation could save the invalida-tion of your boilers guarantee andwill alsopre-vent problems which you may experience inthe future if an inhibitory is not used.

7.5 Lighting the boilerSome products incorporate an anti cycling timedelay. It is normalwhen first switching the boiler onfor the boiler to operate on heating for a few sec-onds then switch off. After 3---4 minutes haselapsed the boiler will then re ignite and operateperfectly normally. The ignition delay cycle doesnot prevent normal operation of the boiler to pro-vide d.h.w..If external controls are fitted (e.g. Timeclock, roomthermostat) ensure they �call for heat�.1 Turn on the electricity supply to the boiler,switching on the fused spur isolation switch.The appliance operation light 10 will flashevery 4 seconds.

2 Turn the function selector 8 as in Fig. 7.3(combi) or Fig. 7.4 (c.h. only). The applianceoperation light 10 will flash every 2 seconds.

810 7 6

Fig. 7.3

810 7 6

Fig. 7.4

The boiler will now go through an ignition se-quence and the burner will light.If during the ignition attempt period the boiler failsto light, the full sequence control p.c.b. will go tolockout and the lock---out signal lamp 6 will ap-pear.To reset the boiler press and release the boiler re-set button 7 (Fig. 7.3).

7.6 Checking the gas pressure atthe burner

This boiler has been tested to the highest qual-ity control standards.

Themaximumandminimumgas pressuresarealready set during this quality control processhowever the checking procedure must be fol-lowed to ensuremaximumoperatingefficiencyfrom the boiler.

INSTALLATION

Page 38: User manual and Installation instructions RIVA …...Lack of burner ignition (no ignition signal from the full seqence ignition device) Ignition gas pressure adjustment Minimum gas

Commissioning

32

1 Remove the front panel of the case (see sec-tion 9.2 in this manual).

2 Loosen the internal screw 37 (Fig. 7.5) on theOutlet Pressure Test Point of theGas Valve andconnect a pressure gauge using a suitablehose.

3 Set the d.h.w. and c.h. temperature controlknobs to their maximum position.

4 Switch on the boiler and open at least one hotwater tap fully.

5 Check the maximum gas pressure and com-pare the value on the gaugewith the value indi-cated in the sections 4.4 or 4.5 (gas pressuresat the burner), accordingly with the model ofboiler installed.

6 Check the maximum gas flow at the gas meterand compare the value indicated in the sec-tions 4.4 or 4.5 (gas rate), accordingly with themodel of boiler installed.

7 Switch off the boiler.8 Disconnect the gas modulator coil by remov-ing the electrical connector A (Fig. 7.5).

37 A

Fig. 7.5

9 Switch on the boiler.10 Check the minimum gas pressure and com-pare the value on the gaugewith the value indi-cated in the sections 4.4 or 4.5 (gas pressuresat the burner), accordingly with the model ofboiler installed.

11 Switch off the boiler and re---connect the elec-trical connector A to the modulator coil.

12 Access the main control panel (see section6.10, follow steps 2 --- 5)

13 Switch on the boiler.

14 Check the ignition gas pressure by settingdip---switch �3� (Fig. 7.8) to the OFF position.Compare thevalue on the gaugewith the valueindicated in the sections 4.4 or 4.5 (gas pres-sures at the burner), accordingly with themodel of boiler installed.If the ignition gas pressure is not set correctlysee section 7.7 in this manual for the adjust-ment procedure. If ignition gas pressure is cor-rect switch dip---switch �3� to the ON position.

15 Switchoff theboiler, turnoff thehot water tap(s)and disconnect the pressure gauge.

If the maximum and minimum gas pressuresmeasuredabovearenot in accordancewith thetechnical data (sections 4.4 or 4.5) then adjust-mentwill be necessary.A full explanation of thegas pressure adjustment procedure is given inthe Gas Valve section of the service manual. Ifmaximum and/or minimum gas pressures areadjusted then the ignition gas pressure mustbe checked and adjusted if necessary.

Important: after the gas pressure checks andanyadjustmentoperations,all of the testpointsand adjustment devices must be sealed.

7.7 Adjusting the burner ignition1 Turn off the boiler by means of the fused spurisolation switch provided adjacent to the ap-pliance.

2 Make sure that the function selector 8 is set tothe position in Fig. 7.6 and that the timer selec-tor switch and room thermostat, if fitted, is setto �demand heat�.

8

Fig. 7.6

3 Unscrew the gas valve�s outlet pressure testpoint 37 (Fig. 7.5) and connect a pressuregauge.

INSTALLATION

Page 39: User manual and Installation instructions RIVA …...Lack of burner ignition (no ignition signal from the full seqence ignition device) Ignition gas pressure adjustment Minimum gas

Commissioning

33

4 Loosen the screws B and remove the servicepanel (Fig. 7.7).

B

Fig. 7.7

5 Turn on the boiler.6 Check that the boiler lights up uniformly andadjust the ignition gas pressure, if necessary.

Toadjust the ignition gaspressure, setdip---switch�3� (Fig. 7.8) to theOFFposition and adjustpoten-tiometer marked �ACC� with a screwdriver untilcorrect ignition gas pressure is obtained.

2 3

4

OFF

ON

1

ACC

RISC

+

+

Fig. 7.8

Refer to the table gas pressures at theburner in thesections 4.4 or 4.5 for appropriate value.7 Having finished this procedure, reset dip---switch �3� to the ON position.

7.8 Adjustment of useful c.h.output

If the burner function selector (dipswitch number4 on the main P.C.B.) is set to the �ON� position itwill activate the re--- ignition delay period of ap-proximately 4 minutes. When dipswitch number 4

is set to the �OFF� position there will be approxi-mately 30 seconds re--- ignition delay period.Whilst checking or adjusting the c.h. output, andfault finding on the boiler it may be necessary toswitch the re--- ignition delay mechanism (dips-witch 4) to the �OFF� position.Refer to the diagrams shown in Fig. 7.9, Fig. 7.10or Fig. 7.11 and select the correct central heatingoutput gas pressure to meet with the central heat-ing system requirements.With the boiler operating in c.h. mode, use a suit-able screwdriver to turn the adjustment potentio-meter marked �RISC� (Fig. 7.8). Rotating thepotentiometer anti---clockwise reduces the maxi-mum supply current to the gas modulator device,and thus reduces the gas pressure to the burner.

10121416182022242628

2 3 4 5 6 7 8 9 10 11 12

kW

mbar

Natural (G20)

M90D.24SM90D.28S

Fig. 7.9

INSTALLATION

Page 40: User manual and Installation instructions RIVA …...Lack of burner ignition (no ignition signal from the full seqence ignition device) Ignition gas pressure adjustment Minimum gas

Commissioning

34

10121416182022242628

6 9 12 15 18 21 24 27

kW

mbar

Butane (G30)

M90D.24SM90D.28S

Fig. 7.10

10121416182022242628

8 11 14 17 20 23 26 29 32 35

kW

mbar

Propane (G31)

M90D.24SM90D.28S

Fig. 7.11

7.9 Checking the ignition deviceWith the burner on high flame close the gas cock.About 10 seconds after, the lock---out signal lamp6 (Fig. 1.3 on page 1) must appear.To reset the boiler press and release the boilerreset button 7 (Fig. 1.3 on page 1).

7.10 Checking the flue systemThe flue system should be visually checked forsoundness. Check all clamps, gaskets and fixingsare secure and tight.Ensure that the flue terminal is sited correctly in ac-cordance with the flue fitting instructions andFig. 5.1 on page 20 of this manual.To carry out a combustion check refer to the in-structions given in the section 9.5 of this manual.Reference figures are given in the sections 4.4 or4.5 of this manual (Flue gas figures).

7.11 Instructing the userHand over this combined User & Installation man-ual and the Servicemanual to the enduser andex-plain how to use the unit in both c.h. and d.h.w.modes.Take the User step by step through the lighting in-structions.Show the User how to switch off the appliancequickly and indicate the position of the electricsupply isolator.Explain the proper use and adjustment of all sys-tem controls; this will ensure the greatest possiblefuel economy.Explain the function and use of the function selec-tor.Explain and demonstrate the function of time andtemperature controls (if fitted).Explain how to turn off the appliance for both shortand long periods and advise on the precautionsnecessary to prevent damage should theappliance be inoperative when freezing condi-tions may occur.Fill in the details required on the Boiler GuaranteeCertificate and hand to the User advising them toreturn the correct section forboiler Guarantee reg-istration.Finally, advise the User that, for continued safeand efficient operation, the appliancemust beser-viced by a competent person at least once a year.

INSTALLATION

Page 41: User manual and Installation instructions RIVA …...Lack of burner ignition (no ignition signal from the full seqence ignition device) Ignition gas pressure adjustment Minimum gas

8 GAS CONVERSION

35

8.1 WarningsProcedures to adapt the boiler to the type ofgas available must be carried out by a com-petent and responsible person.Components used to adapt it to the type of gasavailable must be genuine parts only.

8.2 Procedures1 Check that the gas cock (13 in Fig. 9.3) fittedunder the boiler is turned off and the applianceis is switched off at the mains isolating spur.

2 Remove the front and side panels of the case(see the section General access and emptyinghydraulic circuits in the service manual).

3 Take off the lid of the sealed chamber.4 Take the front panel of the combustionchamber off and remove the burner (29 onpage 11). See section Ignition and detectionelectrodes in the servicemanual for detailed in-structions.

5 Carry out the conversion for the type of gas, re-placing the burner injectors correctly.

6 Re---assemble the burner, the front panel of thecombustion chamber and the lid of the sealedchamber.

7 Extract the control panel as explained in thesection 6.10 of this manual.

8 Loosen the screws C and remove the servicepanel (Fig. 8.1).

C

Fig. 8.1

9 set correctly the dip---switch �2� to the correctposition (Fig. 8.2) in accordance with the follo-wing table.

Gas supply Position of dip---switch 2

Natural gas On

L.P.G. Off

ON

OFF

1 2 3 4

ON

OFF

123 4

Natural gas L.P.G.

Fig. 8.2

10 Calibrate the gas valve according to the in-structions given in the service manual, sectionModulating gas valve --- Adjustment.

11 Set the correct gas pressure for central heatingoutput required, see section 7.8 in thismanual.

12 Stick on the inside of the left hand side paneladjacent to the data badge the self ---adhesivelabel (included with the conversion kit) indicat-ing the type of gas, and the gas pressures towhich the appliance has been set.

13 Replace the service panel, the front and sidepanels of the case.

MAINTENANCE

Page 42: User manual and Installation instructions RIVA …...Lack of burner ignition (no ignition signal from the full seqence ignition device) Ignition gas pressure adjustment Minimum gas

9 MAINTENANCE

36

9.1 WarningsThe procedures detailed in this chapter mustbe carried out only by a professionallyqualified person. Thus you are advised tocontact an Authorised Service Agent.

For Ireland (IE), the servicing work must becarried out by a competent PersonFor efficient and continuous operation of theboiler you are advised to have, at least once ayear, maintenance and cleaning done by anApproved Service engineer.Isolate the appliance from the electricitysupply by turning off the fused spur isolationswitch adjacent to the appliance and turn offthe gas cock, before carrying out any pro-cedures, whatsoever, for cleaning, mainten-ance, opening or dismantling boiler panels.

9.2 Dismantling the externalpanels

Front panel1 Loosen the two screws A (Fig. 9.1).2 Lift and remove the panel.

A

Fig. 9.1

Side panels3 Loosen the screws B. Bring the bottom of thepanels away from the boiler and lift them, free-ing them from the top hooks (Fig. 9.2).

BFig. 9.2

9.3 Emptying the d.h.w. system(combi)

1 Turn off the d.c.w. inlet isolating valve (12 inFig. 9.3) and turnon thehot water taps andanydrain cocks.

Closed position131215

11

Fig. 9.3

9.4 Emptying the c.h. system1 Close the c.h. isolating valves (11 and 15 inFig. 9.3).

MAINTENANCE

Page 43: User manual and Installation instructions RIVA …...Lack of burner ignition (no ignition signal from the full seqence ignition device) Ignition gas pressure adjustment Minimum gas

Maintenance

37

2 Open the central heating drain cock (17 inFig. 9.4).

17Fig. 9.4

3 A small quantity of water will remain in thed.h.w. heat exchanger after draining. If theboiler is being drained to prevent freezing, thed.h.w. heat exchanger must be removed andinverted to drain fully or an antifreeze solutionadded.

9.5 Combustion analysis checkTo carry out a combustion analysis:1 remove the frontpanel of the case (see thesec-tion 9.2 in this manual).

2 Remove the plugs indicated in Fig. 9.5.

Sampling pointsAir--- Flue exhaust

Fig. 9.5

3 For correct sampling insert the analyser probeaproximately 110 mm into the exhaust gas/airintake sampling points.

Reference figures are given in the sections 4.4 or4.5 of this manual (Flue gas figures).

9.6 Cleaning the primary heatexchanger

1 Take off the front of the case.2 Take off the removable front of the air--- tightchamber and the front panelof thecombustionchamber.

If you notice dirt on the fins of the primary heat ex-changer (31 on page 11):3 cover the sloping surfaces of the burner (29 onpage 11) entirely in a protective layer (sheetsofnewspaper or similar).

4 Brush out the primary heat exchanger (31 onpage 11) with a bristle paintbrush.

NOTE --- When removing the airtight chambercover it is not necessary to remove the screws lo-cated at the top edge on either side.

MAINTENANCE

Page 44: User manual and Installation instructions RIVA …...Lack of burner ignition (no ignition signal from the full seqence ignition device) Ignition gas pressure adjustment Minimum gas

Maintenance

38

9.7 Checking the pressurisationin the expansion vessel

Empty the central heating system as described insection 9.4 of this chapter and check that thepres-sure in the expansion vessel is not less than 1 bar.See also section 4.7 page 18 of this manual.If the pressure is lower, take steps to correct thepressure level.

9.8 Cleaning the burnerThe sloping and multi---gas type burner (29 onpage 11) does not need special maintenance, butit is sufficient to dust it with a bristle paintbrush.To reach the burner:1 Take off the front of the case.2 Take off the removable front of the air--- tightchamber and the front panelof thecombustionchamber.

3 Brush out the burner with a bristle paintbrush.NOTE --- When removing the airtight chambercover it is not necessary to remove the screws lo-cated at the top edge on either side.

9.9 Checking the flueHave the integrity of the flue outlet pipe (45 onpage 12) air intake pipe (46 on page 12), checkedperiodically, the venturi device* (42 on page 12)cleaned and the efficiency of the flue safety circuitchecked at least once a year.* For details see the section Fan, venturi deviceand air pressure switch in the service manual.For all the above maintenance operations it is ad-visable to call an approved Service Engineer.

9.10 Visual inspection ofappliance

Visually inspect all water joints, seals and connec-tions for any evidence of leakage and retighten,grease or replace them as necessary.

9.11 Gas pressures andsoundness

Check appliance for gas soundness. Recheckop-erational pressures and adjust as necessary asdescribed in section 7.6 page 31 of this manual.

MAINTENANCE

Page 45: User manual and Installation instructions RIVA …...Lack of burner ignition (no ignition signal from the full seqence ignition device) Ignition gas pressure adjustment Minimum gas

Maintenance

39

MAINTENANCE

Page 46: User manual and Installation instructions RIVA …...Lack of burner ignition (no ignition signal from the full seqence ignition device) Ignition gas pressure adjustment Minimum gas
Page 47: User manual and Installation instructions RIVA …...Lack of burner ignition (no ignition signal from the full seqence ignition device) Ignition gas pressure adjustment Minimum gas
Page 48: User manual and Installation instructions RIVA …...Lack of burner ignition (no ignition signal from the full seqence ignition device) Ignition gas pressure adjustment Minimum gas

*1796209138*17962.0913.8 4106 48A5 UK

Biasi UK LtdNewman Park, Western WayWednesbury, WS10 7BJSales Tel No: 0121 506 1340Sales Fax No: 0121 506 1360Service Tel No: 0121 506 1350Service Fax No: 0121 506 1370www.biasi.co.uk