user guidef01.s.alicdn.com/kf/htb11wnmfvxxxxc0xvxx.prxfxxxd.pdf · 2019-08-01 · 1 evolutionary...
TRANSCRIPT
1
Evolutionary solution for Body and Face Care
Cool Sculpting V9User Guide
Thanks for choosing our product
Please read through the manual before using
If any changes, our company reserves the right of final Interpretation
2
ContentsOperating Manual
Structure of Cool Sculpting V9 ……………………………………………3General Structure . ………………………………………….3Applicator Description ………………………………………….4Applicator Installation . ………………………………………….5~6
After-Sale Service . …………………………………………..71. Warranty …………………………………….………72. Maintenance . …………………………………………..7
Cautions ………………………………………81, Contraindication …………………………………………82. Cautions when use ....…………………... …………………83. Cautions after use …………………………………………8
Operation …..………...…………………………….9~181. Function selection …………………………………………...92. Vacuum & Cavitaiton ………………………………………...10~143. Cryolipolysis & Electrophoresis & Vacuum ……………………………15~164. Cryolipolysis & Electrophoresis ………………...……………………….165. Body RF …………………………………………….176. Face RF …………………………………………….18
Finish …………………………………………….19
Contact Info …………………………………….………19
Specification …………………………………….……...19
3
Structure of Cool Sculpting V9General Structure
4
Description of Applicators
5
Structure of Cool Sculpting V9Applicator InstallationPlease make sure the water tank is filled with water before Applicator Installation
1. Big handle with two cavitation transducers & vacuum & LED, treated on bodyColor display on the top of handle can show power transformation of the twofunctionsThe maximum power energy 99% showed on the display is equivalent to 100%on touch screen.Left side button adjust cavitation powerRight side button adjust vacuum power.
Hold the Vacuum & Cavitation handle on the holder; insert it to Vacuum &Cavitation socket.
2. Cryolipolysis PlatesCombined Cryolipolysis and Electrophoresis together
Hold the Cryolipolysis plate on the holder; insert it to the Plate’s socket.
3. Cryolipolysis Electrophoresis Vacuum handle
Combined Cryolipolysis &Vacuum & Electrophoresis together for body areaTwo Cryolipolysis & Electrophoresis Plates inside of the handle
Hold the Cryolipolysis handle on the holder; insert it to the RF socket.
6
4. Emergency BarControl the Vacuum function, press it to stop suction, it has the same function asthe black button on the Cryolipolysis vacuum handle
Hold the handle on the holder; insert it to the Emergency Bar socket
4. Body RF Handle, 10MHz multi-polar RF, treated on Body areaHold the body RF handle on the holder; insert it to the Body RF socket
5. Face RF Handle, 10MHz multi-polar RF, treated on Face & Neck area.Hold the body RF & Vacuum handle on the holder; insert it to the Body RF socket
6. Foot Switch, use for start RF treatment, Keep stepping it when doing RF treatmentHold the Foot Switch on the holder; insert it to the Foot Switch socket.
7
After-Sale ServiceWarrantyHEMS stipulates the warranty for the original purchaser as follows:
HEMS provides 12 months warranty period on its any product for any defectcaused by material or manufacturing quality starting from the installation day.According to the warranty stipulation, HEMS's responsibilities are limited torepair and replacement of the part and material recognized in conformity withabove conditions.HERMES won't bear any responsibility for any damage caused by misapplicationof the user or repair of disapproval
Out of WarrantyA product that has no SERIES NumberApplicators dropping or any shockApplicator acrylic rack
Maintenance AdvantageEasy to check and confirm the problemSimple to find out the solutionQuick to replace Function Module
Maintenance PolicyMust provide the photo, even the Video depends upon the different situation
Without manufacturer’s permission, purchaser can’t send back the machine, otherwise,the purchaser has to bear the transportation fee and the customs tax and manufacturerhas the right to refuse to handle.
8
CautionContraindicationPlease avoid the treatment from the following patients1. Pregnant women or women who may be pregnant2. Cardiopaths3. Patients with vascular diseases4. Patients with pacemakers5. Patients with therombosis and or thrombophlebitis6. Patients being treated with anticoagulants7. Patients who have undergone a transplant8. Carriers of large metal prostheses9. Diabetics10. Epileptics
Caution when use
Cavitation FunctionApply Sufficient Amount of gelKeep the applicator in full contact with treatment areaDo not keep the applicator at the same placeMove the applicator slowly, But constantlyAvoid the treatment over bone and do not aim directly to the jointAlways make a skin fold in order to get better access to the fat tissueIn case of resting during treatment, please “PAUSE” and then “STOP” to avoidover-output of the machineAfter one client treatment or 2 hours usage, please allow about 20 minutes restingof system, it can prolong the lifetime of cavitation applicator
Radio Frequency FunctionApply sufficient amount of gelKeep the applicator in full contact with treatment area, then step the foot-switchto start the treatmentDo not keep the applicator at the same placeMove the applicator slowly, but constantly
Cryolipolysis FunctionUse protection of frost film to prevent skin frostbite
Combination treatmentWe recommend doing treatment as the following procedure at the same area:20~40 minutes Cavitation & Vacuum +20 minutes CRYO + 20~40 minutes RF
● We recommend making sure every treatment area should treat 20 minutes to getbetter results. So in some Auto programs which treatment time is 10 minutes perarea, we recommend repeating the session once.
9
OperationFunction selection
Main Function Interface
1.Vacuum &Cavitation :Touch it and enter into
Cavitation & Vaccum function interface
2. Cryolipolysis & Electrophoresis & Vacuum :touch it and enter into Cryolipolysis & Electrophoresis & Vacuum function interface.
3. Cryolipolysis & Electrophoresis : touch it andenter into Cryolipolysis & Electrophoresis function interface.
4. Body RF & Vacuum : touch it and enter into BodyRF&Vacuum function interface.
5. Face RF & Vacuum : touch it and enter into FaceRF&Vacuum function interface.
10
OperationVacuum & Cavitation Function
Choose Operation Mode
1. Auto Program : automatically operationprogram on different treatment area, touch this button and enter into automaticallyoperation interface
2. Manual Selection : Select OperationSpecifications Manually, touch this button and enter into manually operation interface
3. Back : touch this button return to the Main Function Interface
11
Auto Program Mode
1. Abdomen & Flanks : touch thisbutton and enter into the automatically operation interface of Abdomen and flankarea.
2. Thighs & Buttocks : touch thisbutton and enter into the automatically operation interface of buttocks and outboardthighs area.
3. Inner Thighs : touch this button and enter into theautomatically operation interface of inboard thighs area.
4. Edematous Cellulite : touchthis button and enter into the automatically operation interface of Edematous Cellulitearea.
5. Back : touch this button return to the Operation Mode Interface
12
ABDOMEN & FLANKS Treatment
1. Select Cavitation working mode: or (Default mode is )
2. Select Cavitation power: Select power among, , or when
selected working mode(default power is )
Select one power among 40W, 50W, 60W when selected working mode
(default power is 50W)
3. Select the Vacuum working mode through , , , (Default mode
is )
4. Start the treatment: Touch to Start the Abdomen & Flanks area treatment
5. Pause button : Pause the treatment.
If need to change working mode or working power during treatment, please touch
button first, then select the power and mode.
6. Stop button : Stop the treatment.
7. Back button : Return to the Auto Program Mode interface
8. Button: the total treatment time is 40 mins
10. Button: treatment time of left Abdomen is 10 minutes
11. Button: treatment time of right Abdomen is 10 minutes
13
12. Button: treatment time of left Flanks is 10 minutes
13. Button: treatment time of right Flanks is 10 minutes
Operation steps of the rest of Auto Programms are similar as ABDOMEN &FLANKS
Remak
Cavitation Working Modes:
1. Working mode: Power can be adjusted among 60W, 70W and 80W5s/1s pulsation output mode
2. Working mode: Power can be adjusted among 80W, 45W and 50W0.5s/0.5s pulsation output mode
3. Working mode: Power can be adjusted among 40W, 50W and 60WContinuously output mode
Vacuum Working Modes:
1. working mode: continuous mode
2. working mode: Pulse mode, suck 2 seconds and then release
3. working mode: Pulse mode, suck 3 seconds and then release
4. working mode: Pulse mode, suck 4 seconds and then release
14
MANUAL OPERATION Mode
1. Set the Vacuum Power: Touch and from 0% to 100%, every 10%a interval.
2. Set the Vacuum working mode: select the vacuum working mode through
, , , (Default mode is )
3. Set the Cavitation working mode (Pulse/Cont mode): Touch and
4. Set the Cavitation Power: Touch and from 0% to 100%, every 10%a interval.
5. Set the treatment time: Touch and to adjust the treatment time, total
treatment time is 30 minutes (present time: ).
6. Start the treatment: Touch to Start the Abdomen & Flanks areatreatment
7. Pause button : Pause the treatment.
If need to change working mode or working power during treatment, please
touch button first, then select the power and mode.
8. Stop button : Stop the treatment.
9. Back button : Return to the Auto Program Mode interface
15
OperationCryolipolysis & Electrophoresis & Vacuum Function
1. Set the Vacuum Power: Touch and from 0% to 100%, every 10%a interval.
2. Set the Vacuum working mode: select the vacuum working mode through
, , , (Default mode is )
3. Set the Electrophoresis working mode: Touch and to set different
modes. (Default mode is )
4. Set the Electrophoresis Power: Touch and to adjust the power
from 0% to 100%, every 10% a interval.
5. Set the treatment time: Touch and to adjust the treatment time, totaltreatment time is 30 minutes (present time: 20 minutes).
6. Start the treatment: Touch to Start the Abdomen & Flanks area treatment
7. Pause button : Pause the treatment.
If need to change working mode or working power during treatment, please touch
button first, then select the power and mode.
8. Stop button : Stop the treatment.
16
9. Back button : Return to the Auto Program Mode interface
10. CRYO : To show the Cryolipolysis therapy is working
Operation of Cryolipolysis & Electrophoresis Plates is similar as
Cryolipolysis & Vacuum function
Electrophoresis working mode
1. Mode : Galvanic Current,
Leading ion to permeate into the skinBreaking down the contamination in the skinAccelerating cell updated speedStimulation the speed of fluid flow
2. Mode : Faradic Current Square Wave
Stimulating muscle contractions & passive movementLifting, tightening and Contouring Sagging Skin
3. Mode : Faradic Current Spike Wave
Stimulating Muscle intensivelyTraining muscle to build a perfect & firm bodyline
4. Mode : Faradic Current Twin Spike Wave
Powerful Electrophoresis penetrationTransforming fat into energy to consume
5. Mode : Faradic Current Step Wave
Contracting the muscles rhythmicallyAiming at swollen leg exercise
6. Mode : Faradic Current Trapezoid WaveContracting Muscles quicklyImproving the volume of blood circulationDraining away the internal waste of our body
7. Mode : Faradic Current Triangle WaveStimulating lightly to relax exhausted musclesAiming at Lymphatic System Care
17
OperationBody RF Function
1. Set the working mode: Touch and to select working mode between
Pulse mode and Continuous Mode
2. Set the RF Power: Touch and to adjust the RF power from 0% to
100%, every 10% a interval.
3. Set the treatment time: Touch and to adjust the treatment time, total
treatment time is 30 minutes (present time: 20 minutes).
4. Start the treatment: Touch to Start the Abdomen & Flanks area treatment
5. Pause button : Pause the treatment.
If need to change working mode or working power during treatment, please touch
button first, then select the power and mode.
6. Stop button : Stop the treatment.
7. Back button : Return to the Auto Program Mode interface
18
OperationFace RF Function
1. Set the working mode: Touch and to select working mode between
Pulse mode and Continuous Mode
2. Set the RF Power: Touch and to adjust the RF power from 0% to
100%, every 10% a interval.
3. Set the treatment time: Touch and to adjust the treatment time, total
treatment time is 30 minutes (present time: 20 minutes).
4. Start the treatment: Touch to Start the Abdomen & Flanks area treatment
5. Pause button : Pause the treatment.
If need to change working mode or working power during treatment, please touch
button first, then select the power and mode.
6. Stop button : Stop the treatment.
7. Back button : Return to the Auto Program Mode interface
19
Finish
1. If need to clearance the total time, please touch ten times, and then
touch time once.
2. When finish the treatment, Press button.3. Turn off the power switch on the back of the machine.4. Clean the accessories after treatment.
Contact InfoRepair or any enquiry for this, it shall be back to manufacturer,Following address:Guangzhou HERMES Technology Co., Ltd.No.38 Songboliji Ex., Shijing Town, Baiyun District, Guangzhou City, Guangdong,ChinaHotline: 400-633-1980Tel: 86-20-61163310, 61163051Fax: 86-20-61163317E-mail: [email protected]
SpecificationDisplay: 11 inch Color touch screenPower Supply: 110V-120V/220V-240V, 50/60HzTime Setting: 5 to 30 minutesCavitation power: 82WCavitation Frequency: 32 KHz±10%Vacuum Power:-102KPaRF Frequency: 10MhzCryolipolysis Temperature: -5℃Electrophoresis Mode: 7 Modes