IXL Eco VentfloModel: 10324 (200mm) - Extraction Rate: 340m3/hModel: 10326 (250mm) - Extraction Rate: 490m3/h Electrical Rating: 230~240 V. 50 Hz.
WelcomeThank you for buying this IXL Eco Ventflo Fan. Even if you have used an exhaust fan before, there are some very good reasons to read this user guide before using this one:• Youandyourfamily,propertyandhomewillbesafefromharm.• Youwilllearnhowthisappliancemaydifferfromothers.• ByusingtheVentfloFanfullyandproperly,youwillgetmaximumlifeandvaluefromit.• OurwarrantydependsonyouusingtheVentfloFanaccordingtothisuserguide.Itwillonlytakeyouafewminutes,sopleasereadon!
ContentsSafety ............................................................................Pg 3-4
Ventilation Requirements ................................................ Pg 5
Clearances ....................................................................... Pg 6
Flat Roof Installations ..................................................... Pg 7
Electrical Requirements .................................................. Pg 7
Wiring Diagrams .............................................................. Pg 8
Installation ....................................................................... Pg 9
Use.................................................................................. Pg 10
Cleaning ......................................................................... Pg 10
Record Your Model ........................................................ Pg 11
Warranty ...................................................................Pg 12-13
Notes .............................................................................. Pg 14
Template for Cut Out ...................................................... Pg 15
SafetyIXL Eco Ventflo
Read through these instructions fully before commencing installation.LocatetheIXLEcoVentfloinaccordancewiththerequirementsofthecurrentAustralian/NewZealandWiringRulesAS/NZS3000relatingtodampsituations,oraccordingtoapplicableWiringRulesforinstallationsoutsideofAustraliaandNewZealand.ThisappliancehasanIPX4ratingwhichmeansitissuitableforZone1installationsandcanbemounteddirectlyaboveabathorshowerrecess.Thisunitisfittedwithacordandplug,however,anyinterconnectingwiringandswitchesusedmustbe fitted by a licensed electrician.Switchesandothercontrolsmustnotbelocatedwheretheycanbetouchedbyapersoninthebath orshower.Warning:• Donotusethisapplianceforfunctionsotherthanthosedescribedinthisuserguide.• Afterremovingtheappliancefromitspackaging,ensurethatitiscompleteandundamaged. IfindoubtcontactaqualifiedelectricianorSampfordIXL.Donotleavepackagingwithinthereachofchildrenorinfirmpersons.
• Thisapplianceisnotintendedforusebypersons(includingchildren)withreducedphysical,sensoryormentalcapabilities,orlackofexperienceandknowledge,unlesstheyhavebeen givensupervisionorinstructionconcerningtheuseoftheappliancebyapersonresponsiblefortheir safety.
• Youngchildrenshouldbesupervisedtoensuretheydonotplaywiththeappliance.• Donotoperatetheapplianceinthepresenceofinflammablevapours (alcohol,insecticides,petrol,etc.)
• Donotsitorplaceobjectsonorintheappliance.• Thesupplycordcannotbereplaced.Ifthecordisdamagedtheapplianceshouldbescrapped.• Donotoperatethisappliancewithouttheplasticsurroundinposition.• Thisappliancemustbemountedwiththelowestpointatleast2.1metresfromthefloor.
Caution:• Donotmakemodificationsofanykindtothisappliance.• Donotexposethisappliancetotheweather(rain,sun,etc.)• Donotimmersetheapplianceoranypartsofitinwaterorotherliquids.Refertotherelevantinstructionstocleantheappliance(page10)
Do not allow insulation material to rest against the sides or top of the Ventflo unit when installed.
2
Ventilation RequirementsSafety cont.
Formaximumefficiencyandfanperformancethereareafewkeypointstokeepinmindwheninstallingyour IXL Eco Ventflo exhaust fan.
SufficientairinletintoroomSteamwillonlyberemovedifthereissufficientflowof air through the room. Ensure generous inlets exist throughwindows,ventsorunderthedoor.Airflowpathfrominlettofanshouldideallypassoverthesteamsources.(SeeFig1.)
AdequateventilationinroofcavityItisessentialthatthereisadequatespacewithinthe roof cavity so that exhaust air from the fan can dissipate.Wherespaceisrestricted,useFig.3asaguidetominimumrequirementsforadequateventilation.Theroofcavityitselfshouldbewellventilatedtooutside so that moist air can be removed. Local buildingcodesmayrequireflueingtooutsidethroughroofasperFig.4(page7)forflatroofinstallation.
WhereventilationspaceisrestrictedThisproductisnotrecommendedforinstallationbetweenfloorsofmulti-storeydwellings,orwherespacewithintheroofcavityisseverelyrestrictedandaflueasperFig.4cannotbefitted.IXLhasotherVentilationproductsavailablethatareparticularlysuitedtoinstallationsbetweenfloorsorwherespaceisrestricted.ContactyournearestIXLServiceCentreon the numbers located on the back of this booklet.
For further details and advice on ventilation products and tips, visit the IXL Ventilation Selection Guide on our website: www.sampfordixl.com.au
4
• Iftheappliancedoesnotfunctioncorrectlyordevelopsafault,contactSampfordIXLimmediately.• Shouldtheappliancebedroppedorsufferaheavyblow,haveitcheckedbyanauthorisedserviceagentforIXLproducts
• Theelectricalsystemtowhichtheapplianceisconnectedmustconformtoapplicablestandards.• Theelectricalpowersupply/sockettowhichtheapplianceistobeconnectedmustbeabletoprovidethemaximumelectricalpowerrequiredbytheappliance.Ifitcan’tdothis,contactaqualifiedelectriciantomakethenecessarymodifications.
• Switchofftheapplianceattheinstallation’smainswitch:a)iftheappliancedoesnotfunctioncorrectly;b)beforecleaningtheoutsideoftheappliance;c)iftheapplianceisnotgoingtobeusedfor any length of time.
• Theroommusthaveanadequatesourceofreplacementairforthisappliancetofunctioneffectively.Moreover,ifthereisanynon-sealedcombustionbasedappliancesuchasawaterheater,gasstove,etc.inthesameroom,airreplacementmustbesufficientforallappliancestoworkeffectivelytogether.
• Keeptheappliance’sinletgrillefreefromdusttoensureoptimumairflow
IXL Eco VentfloIXL Eco Ventflo
Fig. 1: Ideal placement of Ventflo. Sufficient air inlets into room are required.
Shown installed between shower and bath
Shown installed above shower
Clearances
Allappliancesmustbemountedsothatthelowestpointisatleast2.1mabovethefloor.TheIXLEcoVentfloisdesignedtofitaceilingcavitywithaminimum height of 215 mm (10324) & 260 mm (10326)wheninstalledinawellventilatedroofcavity. Where ventilation is restricted, these heights should be increased by a minimum of 25 mm. This willallowforthebackdraughtshutterstoopenfullywhentheunitisinoperation.Additionally,aminimumof40mmclearanceisrequiredbetweenthesidesofthefanandanyadjoiningpartsoftheroofstructure,suchaswalls,joistsorinsulationbatts.
Figure 3 measurement A:Model 10324 (Ventflo 200) 215mmmin.wherethereisgoodventilationtothesides of the unit.240mmmin.whereventilationtothesidesoftheunit is restricted.Model 10326 (Ventflo 250) 260mmmin.wherethereisgoodventilationtothesides of the unit.285mmmin.whereventilationtothesidesoftheunit is restricted.
Figure 3 measurement B:40mmmin.clearanceonallsidestoallowclipstofullyrotateoutwards.
DRNCHKAPPREL
3rd ANGLE PROJECTIONTHIS DRAWING AND DESIGN REMAINS THE PROPERTY OF SAMPFORD IXL PTY. LTD. THE
INFORMATION IS CONFIDENTIAL AND IS NOT TO BE REPRODUCED OR DISCLOSED TO ANY PARTY OUTSIDE
YOUR ORGANISATION WITHOUT PRIOR WRITTEN AUTHORISATION FROM SAMPFORD IXL PTY. LTD.
Pty. Ltd.
MATL
NAME
SCALE SHEET DRG ISSUE
SAMP
FORD
IXL -
SHE
ET S
IZE
A1
2 OF 4 10324 instructions1:2 A
UNLESS OTHERWISE STATEDDIMENSIONS IN MILLIMETRES
TOLERANCES
LINEARHOLE GROUPSBLANK DIM,SHOLESANGULAR 0.5
0.1
0.20.2
0.2
DRN--
---
A
B
C
D
E
F
G
H
1 2 3 4 5 6 7 8 9 10 11 12
-
gMASS
VENTFLO 200 - AXIAL FAN
VOLUME mm3
Fig. 2: Adequate open space in the roof cavity is required
A
B
FLAPS
DRNCHKAPPREL
3rd ANGLE PROJECTIONTHIS DRAWING AND DESIGN REMAINS THE PROPERTY OF SAMPFORD IXL PTY. LTD. THE
INFORMATION IS CONFIDENTIAL AND IS NOT TO BE REPRODUCED OR DISCLOSED TO ANY PARTY OUTSIDE
YOUR ORGANISATION WITHOUT PRIOR WRITTEN AUTHORISATION FROM SAMPFORD IXL PTY. LTD.
Pty. Ltd.
MATL
NAME
SCALE SHEET DRG ISSUE
SAMP
FORD
IXL -
SHE
ET S
IZE
A1
1 OF 4 10324 instructions1:1 A
UNLESS OTHERWISE STATEDDIMENSIONS IN MILLIMETRES
TOLERANCES
LINEARHOLE GROUPSBLANK DIM,SHOLESANGULAR 0.5
0.1
0.20.2
0.2
DRN--
---
A
B
C
D
E
F
G
H
1 2 3 4 5 6 7 8 9 10 11 12
-
gMASS
VENTFLO 200 - AXIAL FAN
VOLUME mm3
Fig. 3: Minimum clearances for installation
IXL Eco Ventflo
Electrical Requirements
Flat Roof Installations
Seethewiringdiagram(Fig.5)forsupplyrequirementsandmaximumloadingsforeachmodel.Fansmaybeconnectedtoalightingpowercircuitifloadingpermits.Wiringofthewallswitch(notprovided)andsocketoutletinroofcavitymustbecarriedoutbyaregisteredelectrician.ThewallswitchshouldbelocatedinaccordancetheWiringRulesAS/NZS3000.Itmustnotbeinstalledwhereitcanbereachedbyapersoninthebathorshower.
Wheninstallingintoaflatroofwithinsufficientclearance,orwhereceilingcavityventilationisrestricted, an external venting duct must be installed. Use Fig. 4 as a guide to minimum external outlet requirements.IMPORTANT:Donotattachtheducttothebodyofthefan.Allowfor10-20mmminimumgapbetweenthe fan and the end of the duct. The duct should have a diameter of at least 235mm (10324) & 290mm (10326).
Fig. 4: Minimum external outlet requirements
IXL Eco Ventflo
6
Wiring Diagrams
Fig. 5: Wiring diagram.
IXL Eco Ventflo Installation
Important considerations before installing• Joists,beamsandraftersshallnotbecutornotchedtoinstalltheappliance.• ThisunithasanIPX4ratingwhichmeansitissuitableforZone1installationsandcanbeinstalleddirectlyaboveashowerorbath.
• Fortheexhaustfantoworkefficiently,replacementairofavolumeequivalenttowhatisbeingextractedmustbeabletoentertheroom.Ingeneralthisairwouldbedrawnunderthedoororthroughaslightlyopenwindow.Iftheroomisairtightthefanwillfunctionpoorly.
• Thisproductisdesignedforinstallationinflatceilingonly.Donotmountitonaslopingceiling orverticalwall.
Fig. 7: Mounting clips open
Fig. 6: Mounting clips closed
IXL Eco Ventflo
1. Locatingtheunit–Beforecommencinganycutting,checkintheceilingspacethattherearenoobstructionssuchasceilingjoistsandthatthere is sufficient clearance for the housing. Checkthattheelectricalwiringcanberoutedfromthewallswitchestothemountinglocation.
2. Preparetheceiling–Usingthetemplateprovidedonpage15,marktheceilingwithapenciloutlineandcutouttherequiredhole(10324needs244mm dia. & 10326 needs 294 mm dia. hole).
3. Remove the grille.4. Plugthefanintothepowerpoint.5. Ensurethatthemountingclipsareintheclosedposition,theninsertfanintoceilingcutout.
6. Usingascrewdriver(orabatterydriverwithalowtorquesetting)partiallytightenthescrews. Thiswillmovethemountingclipsintotheopenpositionandholdtheunittotheceiling.
7. Rotatetheunitsothatthegrilledirection linesonthebodyarealignedwiththewalls. Theselinesshowtheorientationofthefascia grillewheninstalled.
8. Tightenthescrews.Donotovertightenasthiscandamageplasterboard.
9. Fitgrilleontounit.Oncefittedthegrillecanbeadjustedtobetteralignwiththewalls.
8
10324:0.13A50Hz,10326:0.25A50Hz
1. Turnthepowerswitchon/offtomakesuretheunitruns2. Runningthefancanexhauststeamandodoursquicklyandefficiently.
Note:Shutoffpowerurgentlywhenanyabnormalitiesoccurinoperation.ThencallalicensedelectricianorIXLservicepersonforinspectionandnecessaryservicework.Donotinsertfingersorthinbarsintothegrillewhentheunitisoperating.Thiscouldcauseharmtoyourselfandtheappliance.Theunitmustnotbeinstalledinaplacethatsuffersfromseverewaterleakage.
1. Shutpoweroffbeforecleaningormaintenance.2. Removegrilleandwipeitwithcareusingadampsoftclothwithamilddetergentifnecessary.Ensurethemotororotherelectricalpartscan’ttouchthewater.
3. Thegrillecanbecleanedinadishwasheronlowheatsetting~45°Candonlywashonthetopshelf.4. Replacethegrilleafteritisthoroughlydry
Use
Cleaning
IXL Eco Ventflo
10
Record Your Model
RECORD THE DETAILS OF YOUR MODEL AND KEEP THE FOLLOWING INFORMATIONDO NOT SEND THIS TO IXL.
InstalledBy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Suburb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DateofPurchase. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ModelNo.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SerialNo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IXL Eco Ventflo
WarrantyIXL Eco VentfloWarranty
ThreeYearReplacementWarrantyThisWarrantyagainstdefectsforyournewlypurchasedIXLproductisproudlypreparedbySampfordIXLPtyLtdof421SmithStreet,Fitzroy,VIC3065,phone1300727421.1. SampfordIXLVentilationproductscomewithguaranteesthatdonotexcludethefollowingconsumerentitlementsundertheAustralianConsumerLaw:a.replacementorrefundforamajorfailureandcompensationforanyotherreasonably
foreseeable loss or damage; andb.tohavethegoodsreplacedifgoodsfailtobeofacceptablequalityandthefailuredoesnotamounttoamajorfailure.
2. SampfordIXLwarrantsthatyourproductandrelatedsupplywillbefreefromdefectsinmaterialsandworkmanshipduringthewarrantyterm.Yourwarrantytermisthreeyearscommencingfromthedateofpurchase.
3. SubjecttoPoint1,SampfordIXLwillduringthewarrantytermprovideareplacementofanequivalentcurrentmodelwherethebalanceofthewarrantyperiodfromtheoriginaldateofpurchasewilltakeeffect.
4. TothefullestextentpermittedbylawandsubjectalwaystoPoint1,SampfordIXLwillnotbeliable for:a.anylossordamagearisingfromlossofuse,lossofprofitsorrevenue;orb.foranyindirectorconsequentiallossordamageresultingfromanybreachofthiswarranty
against defects.5. DefectiveSampfordIXLproductsmaybereplacedbyarefurbishedproductofthesametype.
LimitationstoYourIXLWarranty6. SubjecttoPoint1,thisWarranty:a.willonlybeprovidedtotheoriginalpurchaserwheretheoriginalpurchasewasmadefromaSampfordIXLAuthorisedDealerorResellerandproofofsuchpurchasecanbepresentedatthe time of service;
b.onlyappliestoSampfordIXLproductspurchasedinAustraliafromaSampfordIXLAuthorisedDealerorReseller;
c.willnotapplywherethedefectinorfailureoftheproductisattributabletomisuse,abuse,accidentornon-observationofthemanufacturer’sinstructions.Thisproductmustbeusedinaccordancewiththemanufacturer’sinstructions;
d.willnotcoverfaultsduetonormalwearandtearwithreasonableusenorconsumablecomponentssuchasglobes,filters,glassitems,etc;
e.willnotcoveranydamagesorproblemscausedtothisproductbynaturalforceseg.storm,fire,flood,andearthquake;orbyintrusionoraccumulation(orboth)offoreignmatterseg.dust,soil,andmoisture.SampfordIXLrecommendsthatyoutakeoutappropriateinsurancestoprotectyourproducttothisend;
f. willnotapplyifthisproductisinstalledinamobiledwellingeg.caravanorboat;g.willnotapplyifthisproductisremovedfromthelocationwhereitwasfirstinstalled;h.coversuseofthisproductfordomesticuseonly;i. willnotberestartedorextendeduponreplacementoftheproductorapart.
IXL Eco Ventflo
12
HowtomakeaClaimunderYourIXLWarranty7. TomakeaclaimunderthisWarrantyyouwillneedto:a.contactSampfordIXLservicedepartmenton1300727421or aftersalesservice@sampfordixl.com.autoprovidedetailsandregisteryourclaim enablingaSampfordIXLassessment;
b.submitproofofpurchasewithyourclaimeg.taxinvoiceorpurchasereceipt;c.whereapropertyhasbeenconstructedbyabuilder/developeranditisfittedwithIXLproducts,pleasesubmitproofofpurchasebywayofthecertificateofoccupancy, withyourclaim.
8. SampfordIXLwillcontactyoutomakearrangementsforareplacementproduct.
PrivacyTheprivacyofyourpersonalinformationhasalwaysbeenimportanttous.Tolearnmoreabouthowwecollect,keepanduseyourpersonalinformation,pleaseobtainacopyofourprivacystatementbyvisitingourwebsiteatwww.sampfordixl.com.auorbycontactingusviaemailoninfo@sampfordixl.com.auorbytelephoneon1300727421.
Part
num
ber 6
1103
0 Is
sue
A.
Forcomments,questionsorwarrantymatters:
Sampford IXL Pty Ltd ServiceDepartment421SmithStFitzroyVictoria3065AustraliaPhone:1300727421 Fax:[email protected] [email protected]
Approved by the appropriate electrical supply authorities.