WelcomeThank you for buying this IXL Eco Ventflo Fan. Even if you have used an exhaust fan before, there are some very good reasons to read this user guide before using this one:• Youandyourfamily,propertyandhomewillbesafefromharm.• Youwilllearnhowthisappliancemaydifferfromothers.• ByusingtheVentfloFanfullyandproperly,youwillgetmaximumlifeandvaluefromit.• OurwarrantydependsonyouusingtheVentfloFanaccordingtothisuserguide.Itwillonlytakeyouafewminutes,sopleasereadon!

ContentsSafety ............................................................................Pg 3-4

Ventilation Requirements ................................................ Pg 5

Clearances ....................................................................... Pg 6

Flat Roof Installations ..................................................... Pg 7

Electrical Requirements .................................................. Pg 7

Wiring Diagrams .............................................................. Pg 8

Installation ....................................................................... Pg 9

Use.................................................................................. Pg 10

Cleaning ......................................................................... Pg 10

Record Your Model ........................................................ Pg 11

Warranty ...................................................................Pg 12-13

Notes .............................................................................. Pg 14

Template for Cut Out ...................................................... Pg 15

SafetyIXL Eco Ventflo

Read through these instructions fully before commencing installation.LocatetheIXLEcoVentfloinaccordancewiththerequirementsofthecurrentAustralian/NewZealandWiringRulesAS/NZS3000relatingtodampsituations,oraccordingtoapplicableWiringRulesforinstallationsoutsideofAustraliaandNewZealand.ThisappliancehasanIPX4ratingwhichmeansitissuitableforZone1installationsandcanbemounteddirectlyaboveabathorshowerrecess.Thisunitisfittedwithacordandplug,however,anyinterconnectingwiringandswitchesusedmustbe fitted by a licensed electrician.Switchesandothercontrolsmustnotbelocatedwheretheycanbetouchedbyapersoninthebath orshower.Warning:• Donotusethisapplianceforfunctionsotherthanthosedescribedinthisuserguide.• Afterremovingtheappliancefromitspackaging,ensurethatitiscompleteandundamaged. IfindoubtcontactaqualifiedelectricianorSampfordIXL.Donotleavepackagingwithinthereachofchildrenorinfirmpersons.

• Thisapplianceisnotintendedforusebypersons(includingchildren)withreducedphysical,sensoryormentalcapabilities,orlackofexperienceandknowledge,unlesstheyhavebeen givensupervisionorinstructionconcerningtheuseoftheappliancebyapersonresponsiblefortheir safety.

• Youngchildrenshouldbesupervisedtoensuretheydonotplaywiththeappliance.• Donotoperatetheapplianceinthepresenceofinflammablevapours (alcohol,insecticides,petrol,etc.)

• Donotsitorplaceobjectsonorintheappliance.• Thesupplycordcannotbereplaced.Ifthecordisdamagedtheapplianceshouldbescrapped.• Donotoperatethisappliancewithouttheplasticsurroundinposition.• Thisappliancemustbemountedwiththelowestpointatleast2.1metresfromthefloor.

Caution:• Donotmakemodificationsofanykindtothisappliance.• Donotexposethisappliancetotheweather(rain,sun,etc.)• Donotimmersetheapplianceoranypartsofitinwaterorotherliquids.Refertotherelevantinstructionstocleantheappliance(page10)

Do not allow insulation material to rest against the sides or top of the Ventflo unit when installed.

2

Ventilation RequirementsSafety cont.

Formaximumefficiencyandfanperformancethereareafewkeypointstokeepinmindwheninstallingyour IXL Eco Ventflo exhaust fan.

SufficientairinletintoroomSteamwillonlyberemovedifthereissufficientflowof air through the room. Ensure generous inlets exist throughwindows,ventsorunderthedoor.Airflowpathfrominlettofanshouldideallypassoverthesteamsources.(SeeFig1.)

AdequateventilationinroofcavityItisessentialthatthereisadequatespacewithinthe roof cavity so that exhaust air from the fan can dissipate.Wherespaceisrestricted,useFig.3asaguidetominimumrequirementsforadequateventilation.Theroofcavityitselfshouldbewellventilatedtooutside so that moist air can be removed. Local buildingcodesmayrequireflueingtooutsidethroughroofasperFig.4(page7)forflatroofinstallation.

WhereventilationspaceisrestrictedThisproductisnotrecommendedforinstallationbetweenfloorsofmulti-storeydwellings,orwherespacewithintheroofcavityisseverelyrestrictedandaflueasperFig.4cannotbefitted.IXLhasotherVentilationproductsavailablethatareparticularlysuitedtoinstallationsbetweenfloorsorwherespaceisrestricted.ContactyournearestIXLServiceCentreon the numbers located on the back of this booklet.

For further details and advice on ventilation products and tips, visit the IXL Ventilation Selection Guide on our website: www.sampfordixl.com.au

4

• Iftheappliancedoesnotfunctioncorrectlyordevelopsafault,contactSampfordIXLimmediately.• Shouldtheappliancebedroppedorsufferaheavyblow,haveitcheckedbyanauthorisedserviceagentforIXLproducts

• Theelectricalsystemtowhichtheapplianceisconnectedmustconformtoapplicablestandards.• Theelectricalpowersupply/sockettowhichtheapplianceistobeconnectedmustbeabletoprovidethemaximumelectricalpowerrequiredbytheappliance.Ifitcan’tdothis,contactaqualifiedelectriciantomakethenecessarymodifications.

• Switchofftheapplianceattheinstallation’smainswitch:a)iftheappliancedoesnotfunctioncorrectly;b)beforecleaningtheoutsideoftheappliance;c)iftheapplianceisnotgoingtobeusedfor any length of time.

• Theroommusthaveanadequatesourceofreplacementairforthisappliancetofunctioneffectively.Moreover,ifthereisanynon-sealedcombustionbasedappliancesuchasawaterheater,gasstove,etc.inthesameroom,airreplacementmustbesufficientforallappliancestoworkeffectivelytogether.

• Keeptheappliance’sinletgrillefreefromdusttoensureoptimumairflow

IXL Eco VentfloIXL Eco Ventflo

Fig. 1: Ideal placement of Ventflo. Sufficient air inlets into room are required.

Shown installed between shower and bath

Shown installed above shower

Clearances

Allappliancesmustbemountedsothatthelowestpointisatleast2.1mabovethefloor.TheIXLEcoVentfloisdesignedtofitaceilingcavitywithaminimum height of 215 mm (10324) & 260 mm (10326)wheninstalledinawellventilatedroofcavity. Where ventilation is restricted, these heights should be increased by a minimum of 25 mm. This willallowforthebackdraughtshutterstoopenfullywhentheunitisinoperation.Additionally,aminimumof40mmclearanceisrequiredbetweenthesidesofthefanandanyadjoiningpartsoftheroofstructure,suchaswalls,joistsorinsulationbatts.

Figure 3 measurement A:Model 10324 (Ventflo 200) 215mmmin.wherethereisgoodventilationtothesides of the unit.240mmmin.whereventilationtothesidesoftheunit is restricted.Model 10326 (Ventflo 250) 260mmmin.wherethereisgoodventilationtothesides of the unit.285mmmin.whereventilationtothesidesoftheunit is restricted.

Figure 3 measurement B:40mmmin.clearanceonallsidestoallowclipstofullyrotateoutwards.

DRNCHKAPPREL

3rd ANGLE PROJECTIONTHIS DRAWING AND DESIGN REMAINS THE PROPERTY OF SAMPFORD IXL PTY. LTD. THE

INFORMATION IS CONFIDENTIAL AND IS NOT TO BE REPRODUCED OR DISCLOSED TO ANY PARTY OUTSIDE

YOUR ORGANISATION WITHOUT PRIOR WRITTEN AUTHORISATION FROM SAMPFORD IXL PTY. LTD.

Pty. Ltd.

MATL

NAME

SCALE SHEET DRG ISSUE

SAMP

FORD

IXL -

SHE

ET S

IZE

A1

2 OF 4 10324 instructions1:2 A

UNLESS OTHERWISE STATEDDIMENSIONS IN MILLIMETRES

TOLERANCES

LINEARHOLE GROUPSBLANK DIM,SHOLESANGULAR 0.5

0.1

0.20.2

0.2

DRN--

---

A

B

C

D

E

F

G

H

1 2 3 4 5 6 7 8 9 10 11 12

-

gMASS

VENTFLO 200 - AXIAL FAN

VOLUME mm3

Fig. 2: Adequate open space in the roof cavity is required

A

B

FLAPS

DRNCHKAPPREL

3rd ANGLE PROJECTIONTHIS DRAWING AND DESIGN REMAINS THE PROPERTY OF SAMPFORD IXL PTY. LTD. THE

INFORMATION IS CONFIDENTIAL AND IS NOT TO BE REPRODUCED OR DISCLOSED TO ANY PARTY OUTSIDE

YOUR ORGANISATION WITHOUT PRIOR WRITTEN AUTHORISATION FROM SAMPFORD IXL PTY. LTD.

Pty. Ltd.

MATL

NAME

SCALE SHEET DRG ISSUE

SAMP

FORD

IXL -

SHE

ET S

IZE

A1

1 OF 4 10324 instructions1:1 A

UNLESS OTHERWISE STATEDDIMENSIONS IN MILLIMETRES

TOLERANCES

LINEARHOLE GROUPSBLANK DIM,SHOLESANGULAR 0.5

0.1

0.20.2

0.2

DRN--

---

A

B

C

D

E

F

G

H

1 2 3 4 5 6 7 8 9 10 11 12

-

gMASS

VENTFLO 200 - AXIAL FAN

VOLUME mm3

Fig. 3: Minimum clearances for installation

IXL Eco Ventflo

Electrical Requirements

Flat Roof Installations

Seethewiringdiagram(Fig.5)forsupplyrequirementsandmaximumloadingsforeachmodel.Fansmaybeconnectedtoalightingpowercircuitifloadingpermits.Wiringofthewallswitch(notprovided)andsocketoutletinroofcavitymustbecarriedoutbyaregisteredelectrician.ThewallswitchshouldbelocatedinaccordancetheWiringRulesAS/NZS3000.Itmustnotbeinstalledwhereitcanbereachedbyapersoninthebathorshower.

Wheninstallingintoaflatroofwithinsufficientclearance,orwhereceilingcavityventilationisrestricted, an external venting duct must be installed. Use Fig. 4 as a guide to minimum external outlet requirements.IMPORTANT:Donotattachtheducttothebodyofthefan.Allowfor10-20mmminimumgapbetweenthe fan and the end of the duct. The duct should have a diameter of at least 235mm (10324) & 290mm (10326).

Fig. 4: Minimum external outlet requirements

IXL Eco Ventflo

6

Wiring Diagrams

Fig. 5: Wiring diagram.

IXL Eco Ventflo Installation

Important considerations before installing• Joists,beamsandraftersshallnotbecutornotchedtoinstalltheappliance.• ThisunithasanIPX4ratingwhichmeansitissuitableforZone1installationsandcanbeinstalleddirectlyaboveashowerorbath.

• Fortheexhaustfantoworkefficiently,replacementairofavolumeequivalenttowhatisbeingextractedmustbeabletoentertheroom.Ingeneralthisairwouldbedrawnunderthedoororthroughaslightlyopenwindow.Iftheroomisairtightthefanwillfunctionpoorly.

• Thisproductisdesignedforinstallationinflatceilingonly.Donotmountitonaslopingceiling orverticalwall.

Fig. 7: Mounting clips open

Fig. 6: Mounting clips closed

IXL Eco Ventflo

1. Locatingtheunit–Beforecommencinganycutting,checkintheceilingspacethattherearenoobstructionssuchasceilingjoistsandthatthere is sufficient clearance for the housing. Checkthattheelectricalwiringcanberoutedfromthewallswitchestothemountinglocation.

2. Preparetheceiling–Usingthetemplateprovidedonpage15,marktheceilingwithapenciloutlineandcutouttherequiredhole(10324needs244mm dia. & 10326 needs 294 mm dia. hole).

3. Remove the grille.4. Plugthefanintothepowerpoint.5. Ensurethatthemountingclipsareintheclosedposition,theninsertfanintoceilingcutout.

6. Usingascrewdriver(orabatterydriverwithalowtorquesetting)partiallytightenthescrews. Thiswillmovethemountingclipsintotheopenpositionandholdtheunittotheceiling.

7. Rotatetheunitsothatthegrilledirection linesonthebodyarealignedwiththewalls. Theselinesshowtheorientationofthefascia grillewheninstalled.

8. Tightenthescrews.Donotovertightenasthiscandamageplasterboard.

9. Fitgrilleontounit.Oncefittedthegrillecanbeadjustedtobetteralignwiththewalls.

8

10324:0.13A50Hz,10326:0.25A50Hz

1. Turnthepowerswitchon/offtomakesuretheunitruns2. Runningthefancanexhauststeamandodoursquicklyandefficiently.

Note:Shutoffpowerurgentlywhenanyabnormalitiesoccurinoperation.ThencallalicensedelectricianorIXLservicepersonforinspectionandnecessaryservicework.Donotinsertfingersorthinbarsintothegrillewhentheunitisoperating.Thiscouldcauseharmtoyourselfandtheappliance.Theunitmustnotbeinstalledinaplacethatsuffersfromseverewaterleakage.

1. Shutpoweroffbeforecleaningormaintenance.2. Removegrilleandwipeitwithcareusingadampsoftclothwithamilddetergentifnecessary.Ensurethemotororotherelectricalpartscan’ttouchthewater.

3. Thegrillecanbecleanedinadishwasheronlowheatsetting~45°Candonlywashonthetopshelf.4. Replacethegrilleafteritisthoroughlydry

Use

Cleaning

IXL Eco Ventflo

10

Record Your Model

RECORD THE DETAILS OF YOUR MODEL AND KEEP THE FOLLOWING INFORMATIONDO NOT SEND THIS TO IXL.

InstalledBy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Suburb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

DateofPurchase. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

ModelNo.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SerialNo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

IXL Eco Ventflo

WarrantyIXL Eco VentfloWarranty

ThreeYearReplacementWarrantyThisWarrantyagainstdefectsforyournewlypurchasedIXLproductisproudlypreparedbySampfordIXLPtyLtdof421SmithStreet,Fitzroy,VIC3065,phone1300727421.1. SampfordIXLVentilationproductscomewithguaranteesthatdonotexcludethefollowingconsumerentitlementsundertheAustralianConsumerLaw:a.replacementorrefundforamajorfailureandcompensationforanyotherreasonably

foreseeable loss or damage; andb.tohavethegoodsreplacedifgoodsfailtobeofacceptablequalityandthefailuredoesnotamounttoamajorfailure.

2. SampfordIXLwarrantsthatyourproductandrelatedsupplywillbefreefromdefectsinmaterialsandworkmanshipduringthewarrantyterm.Yourwarrantytermisthreeyearscommencingfromthedateofpurchase.

3. SubjecttoPoint1,SampfordIXLwillduringthewarrantytermprovideareplacementofanequivalentcurrentmodelwherethebalanceofthewarrantyperiodfromtheoriginaldateofpurchasewilltakeeffect.

4. TothefullestextentpermittedbylawandsubjectalwaystoPoint1,SampfordIXLwillnotbeliable for:a.anylossordamagearisingfromlossofuse,lossofprofitsorrevenue;orb.foranyindirectorconsequentiallossordamageresultingfromanybreachofthiswarranty

against defects.5. DefectiveSampfordIXLproductsmaybereplacedbyarefurbishedproductofthesametype.

LimitationstoYourIXLWarranty6. SubjecttoPoint1,thisWarranty:a.willonlybeprovidedtotheoriginalpurchaserwheretheoriginalpurchasewasmadefromaSampfordIXLAuthorisedDealerorResellerandproofofsuchpurchasecanbepresentedatthe time of service;

b.onlyappliestoSampfordIXLproductspurchasedinAustraliafromaSampfordIXLAuthorisedDealerorReseller;

c.willnotapplywherethedefectinorfailureoftheproductisattributabletomisuse,abuse,accidentornon-observationofthemanufacturer’sinstructions.Thisproductmustbeusedinaccordancewiththemanufacturer’sinstructions;

d.willnotcoverfaultsduetonormalwearandtearwithreasonableusenorconsumablecomponentssuchasglobes,filters,glassitems,etc;

e.willnotcoveranydamagesorproblemscausedtothisproductbynaturalforceseg.storm,fire,flood,andearthquake;orbyintrusionoraccumulation(orboth)offoreignmatterseg.dust,soil,andmoisture.SampfordIXLrecommendsthatyoutakeoutappropriateinsurancestoprotectyourproducttothisend;

f. willnotapplyifthisproductisinstalledinamobiledwellingeg.caravanorboat;g.willnotapplyifthisproductisremovedfromthelocationwhereitwasfirstinstalled;h.coversuseofthisproductfordomesticuseonly;i. willnotberestartedorextendeduponreplacementoftheproductorapart.

IXL Eco Ventflo

12

HowtomakeaClaimunderYourIXLWarranty7. TomakeaclaimunderthisWarrantyyouwillneedto:a.contactSampfordIXLservicedepartmenton1300727421or aftersalesservice@sampfordixl.com.autoprovidedetailsandregisteryourclaim enablingaSampfordIXLassessment;

b.submitproofofpurchasewithyourclaimeg.taxinvoiceorpurchasereceipt;c.whereapropertyhasbeenconstructedbyabuilder/developeranditisfittedwithIXLproducts,pleasesubmitproofofpurchasebywayofthecertificateofoccupancy, withyourclaim.

8. SampfordIXLwillcontactyoutomakearrangementsforareplacementproduct.

PrivacyTheprivacyofyourpersonalinformationhasalwaysbeenimportanttous.Tolearnmoreabouthowwecollect,keepanduseyourpersonalinformation,pleaseobtainacopyofourprivacystatementbyvisitingourwebsiteatwww.sampfordixl.com.auorbycontactingusviaemailoninfo@sampfordixl.com.auorbytelephoneon1300727421.

NotesIXL Eco Ventflo Template for Cut OutIXL Eco Ventflo

14

Part

num

ber 6

1103

0 Is

sue

A.

Forcomments,questionsorwarrantymatters:

Sampford IXL Pty Ltd ServiceDepartment421SmithStFitzroyVictoria3065AustraliaPhone:1300727421 Fax:[email protected] [email protected]

Approved by the appropriate electrical supply authorities.