usb 3.1 electrical test fixture topologies & tools · usb 3.1 electrical test fixture...
TRANSCRIPT
ii
Revision History
Revision Author Section Change
0.1 Jesse Templin All First draft
0.2 Jesse Templin 4, 5 Added CC jumpers and SigTest Templates
0.3 Jesse Nielsen 2.2, 5.1 Updated mock fixture value, added TJ calibration template
0.4 Jesse Nielsen All Updated Captive Fixture Descriptions
Referenced Documents EnhancedSuperSpeedPHYComplianceTestSpec_1_4_17
USB30_ElectricalTestFixture_Topologies.pdf
Contents 1. Transmitter Tests .................................................................................................................................. 1
1.1. Tx: Standard-A & Micro-B ............................................................................................................. 1
1.2. Tx: Type-C ...................................................................................................................................... 2
2. Receiver Calibration .............................................................................................................................. 3
2.1. Rx Cal: Standard-A & Micro-B ....................................................................................................... 3
2.2. Rx Cal: Type-C Gen2 ...................................................................................................................... 4
3. Receiver Tests ....................................................................................................................................... 5
3.1. Rx: Standard-A & Micro-B ............................................................................................................. 5
3.2. Rx: Type-C Gen1 ............................................................................................................................ 6
3.3. Rx: Type-C Gen2 ............................................................................................................................ 7
3.4. Rx: Type-C Gen1&2 Short Channel ............................................................................................... 8
4. CC Jumpers ............................................................................................................................................ 9
5. SigTest Templates ............................................................................................................................... 10
5.1. Gen1 ............................................................................................................................................ 10
5.2. Gen2 ............................................................................................................................................ 10
1
1. Transmitter Tests
1.1. Tx: Standard-A & Micro-B
See TD.1.1, TD.1.3, TD.1.4, TD.1.5, TD.1.6, and TD.1.7 in the CTS.
Use the same setup for long and short channel tests.
Host
Scope
BERT to Tx
1m Cable
Device
Scope
1m Cable
Device Fixture 1A
Host
Fixture
1A 5.6” CLB
5.6” CLB 5V
Host
Device
BERT to Tx
Device
5V Captive Cable
Tx to Scope BERT to Rx
Captive
Cable
Device
Fixture
Rx Tx
Rx
Tx
Rx
Tx
2
1.2. Tx: Type-C
See TD.1.1, TD.1.3, TD.1.4, TD.1.5, TD.1.6, and TD.1.7 in the CTS.
Use the same setup for long and short channel tests.
Connect jumpers as shown in section 4.
Tx1 or Tx2 can be used on the CLB and Host/Device 1C.
Tx1&Rx1 or Tx2&Rx2 can be used on the Captive Fixture.
Captive Cable
Host
Host
Tx to Scope
BERT to Tx
1m Cable
Host 1C
5.6” CLB
Device 5V
BERT to Rx
Tx to Scope
Captive Cable
Device Fixture
Device
Device
Tx to Scope
BERT to Tx
1m Cable
Device 1C 5.6” CLB
5V
Tx2
Tx1
Tx2
Rx2
Rx1
Tx1
Tx2
Tx1
Tx2
Rx2
Rx1
Tx1
Tx2 Rx2
Rx1 Tx1
3
2. Receiver Calibration
2.1. Rx Cal: Standard-A & Micro-B
See TD.1.8 and TD.1.10 in the CTS.
1m Cable
BERT to Tx
1m Cable
Device
Fixture
1A
Host
Fixture
1A
CLB
CLB
Host
Device & Captive Cable
7.2” Mock Device
7.2” Mock Host
Rx to Scope
Rx to Scope BERT to Tx
Rx
Tx
Rx
Tx
Rx
Tx
Rx
Tx
4
2.2. Rx Cal: Type-C Gen2
See TD.1.10 in the CTS.
Connect jumpers as shown in section 4.
Tx1 or Tx2 can be used on the CLB.
Rx1 or Rx2 can be used on the Mock board.
There is no fixture calibration for Type-C Gen1.
1m Cable
Host
Fixture
1C
CLB
Host
Device & Captive Cable
7.2” Mock
Rx to Scope BERT to Tx
1m Cable Device
Fixture
1C
CLB 7.2” Mock
Rx to Scope BERT to Tx
5V
Tx2
Rx2
Rx1
Tx1
Tx2
Rx2
Rx1
Tx1
Tx2
Rx2
Rx1
Tx1
Tx2
Rx2
Rx1
Tx1
5
3. Receiver Tests
3.1. Rx: Standard-A & Micro-B Gen 2
See TD.1.8, and TD.1.10 in the CTS.
Standard-A and Micro-B Gen 1 Rx Tests require USB 3.0 or 3.1 fixtures.
As of January 2017, there is no official short channel fixture for Standard-A and Micro-B Rx testing.
Use a third party Gen1 short channel fixture.
Host
Tx to BERT
BERT to Tx
1m Cable
Device
Tx to BERT
1m Cable
Device Fixture 1A
Host
Fixture
1A CLB
CLB 5V
Host
Device
BERT to Tx
Device
5V Captive Cable
Tx to BERT BERT to Rx
Captive
Cable
Device
Fixture
Rx Tx
Rx
Tx
Rx
Tx
6
3.2. Rx: Type-C Gen 1
See TD.1.9 in the CTS.
Connect jumpers as shown in section 4.
Tx1 or Tx2 can be used on the CLB and Host/Device 1C.
Tx1&Rx2 or Tx2&Rx2 can be used on the Captive Fixture.
Host
Host
Tx to BERT
BERT to Tx
2m Cable
Host 1C
5G Host/Device
Device
Device
Tx to BERT
BERT to Tx
2m Cable
Device 1C
5V
Captive Cable
Device 5V
BERT to Rx
Tx to BERT
Captive Cable
Device Fixture
5G Host/Device
Tx2
Tx1
Tx2
Rx2
Rx1
Tx1
Tx2
Tx1
Tx2
Rx2
Rx1
Tx1
Tx2 Rx2
Rx1 Tx1
7
3.3. Rx: Type-C Gen2
See TD.1.10 in the CTS.
Connect jumpers as shown in section 4.
Tx1 or Tx2 can be used on the CLB and Host/Device 1C.
Tx1&Rx2 or Tx2&Rx2 can be used on the Captive Fixture.
Host
Host
Tx to BERT
BERT to Tx
1m Cable
Host 1C CLB
Device
Device
Tx to BERT
BERT to Tx
1m Cable
Device 1C CLB
5V
Captive Cable
Device 5V
BERT to Rx
Tx to BERT
Captive Cable
Device Fixture
Tx2
Tx1
Tx2
Rx2
Rx1
Tx1
Tx2
Tx1
Tx2
Rx2
Rx1
Tx1
Tx2 Rx2
Rx1 Tx1
8
3.4. Rx: Type-C Gen1&2 Short Channel
See TD.1.2 and TD.1.10 in the CTS.
Connect jumpers as shown in section 4.
Tx1&Rx1 or Tx2&Rx2 can be used on the Full Breakout.
Full Breakout
5V
(device only)
Host/Device
Tx to BERT
BERT to Rx
Tx2
Rx2 Tx1
Rx1
9
4. CC Jumpers
Only use one jumper.
Place a jumper on CC1 if SMAs are connected to Tx1/Rx1.
Place a jumper on CC2 if SMAs are connected to Tx2/Rx2.
When using the Full Breakout, connect CC to Vbus for devices, or connect CC to GND for hosts.
Tx2 Tx1
Tx2 Tx1
Tx1 Rx1
Tx2 Rx2
Tx1
Rx1 Tx2
Rx2
CC2
CC1
CC2
CC1
CC2
CC1
CC1
CC2
10
5. SigTest Templates
Please refer to the USB-IF website for the SigTest installers. There is one version for Gen1 and a different
version for Gen2 testing. The SSC Profile test (both Gen1 & Gen2) must be performed with the Gen2
version.
5.1. Gen1
Test # Description Tx/Rx SigTest Folder SigTest Template File Name
TD.1.1 Tx LFPS Test Tx USB_3_5GB USB_3_LFPS.dat
TD.1.3 Tx Rj Computation Tx USB_3_5GB USB_3_5Gb_CP1.dat
TD.1.3 Tx Test Tx USB_3_5GB USB_3_5Gb_CP0_RjIN.dat
TD.1.3 Tx Test (Short Channel) Tx USB_3_5GB USB_3_5Gb_CP0_RjIN_SHORT.dat
TD.1.6 Tx SSC Profile Test Tx USB_3_5GB USB_3_5Gb_SSC_Profile_Test.dat
TD.1.8 Rj Calibration Rx Cal USB_3_5GB USB_3_5Gb_CP1.dat
TD.1.9 Rj Calibration (Type-C) Rx Cal USB_3_5GB USB_3_5Gb_CP1_Rj_Cal_Type_C.dat
TD.1.8 Sj Calibration Rx Cal USB_3_5GB USB_3_5Gb_CP0_RjIN_SjCal.dat
TD.1.9 Sj Calibration (Type-C) Rx Cal USB_3_5GB USB_3_5Gb_CP0_RjIN_SjCal_Type_C.dat
TD.1.8 Tj Calibration Rx Cal USB_3_5GB USB_3_5Gb_CP0_RjIN.dat
TD.1.8 EW/EH Calibration Rx Cal USB_3_5GB USB_3_5Gb_CP0_RjIN.dat
5.2. Gen2
Test # Description Tx/Rx SigTest Folder SigTest Template File Name
TD.1.4 Tx Rj Computation Tx USB_3_10GB USB_3_10Gb_CP10_Tx_Rj_Test.dat
TD.1.4 Tx Test Tx USB_3_10GB USB_3_10Gb_CP9_Tx.dat
TD.1.4 Tx Test (Short Channel) Tx USB_3_10GB USB_3_10Gb_CP9_Tx_Short.dat
TD.1.7 Tx SSC Profile Test Tx USB_3_10GB USB_3_10Gb_SSC_Profile_Test.dat
TD.1.5 Tx Equalization Test Tx N/A N/A (Preset GUI Button)
TD.1.10 Rj Calibration Rx Cal USB_3_10GB USB_3_10Gb_Rj_Cal.dat
TD.1.10 Sj Calibration Rx Cal USB_3_10GB USB_3_10Gb_Sj_Cal.dat
TD.1.10 EW/EH Calibration Rx Cal USB_3_10GB USB_3_10Gb_CP9_Rx_CAL_CTLE_N5dB.dat