ur gen iii

15
Presenting CB3 1

Upload: ben-blower

Post on 23-Jun-2015

147 views

Category:

Engineering


2 download

TRANSCRIPT

Page 1: Ur gen iii

1

Presenting CB3

Page 2: Ur gen iii

 

What’s the same?

2

Page 3: Ur gen iii

3

What’s the same?

UR5 CB2 UR5 CB3

Page 4: Ur gen iii

4

What’s the same?

Technical specs in terms of performance

UR5 UR10

Payload 5 kg 10 kg

Reach 850 mm 1300 mm

Joint ranges +/-360˚ +/-360˚

Repeatability +/-0.1 mm +/-0.1 mm

Joint speed 180˚/sec 120/180˚/s

Tool speed 1000 mm/sec 1000 mm/sec

Weight 18.4 kg 28.9 kg

IP rating IP54 IP54

Temp. Range 0-50˚C 0-50˚C

Page 5: Ur gen iii

5

What’s the same?

Key value drivers

Easy programming Fast set-up Flexible deployment Collaborative and Safe Fast payback

Page 6: Ur gen iii

What’s the difference?

6

Page 7: Ur gen iii

7

CB3 key new features

Adjustable safety

Absolute encoders

Additional I/O

Runtime improvements

Page 8: Ur gen iii

8

Adjustable safety

Adjustable safety settings

All safety functions are rated as Performance Level d

Certified by TÜV

Tested in accordance with: EN ISO 13849-1:2008 PLd EN ISO 10218-1:2011

Page 9: Ur gen iii

9

UR Safety 3.0

Configurable safety system Safety can be adjusted to the individual

application

Two safety modes Normal mode Reduced mode

Switch mode by Digital input Entering boundary

Page 10: Ur gen iii

10

UR Safety 3.0

Adjustable safety functions Joint position limits Joint speed limits TCP Plane limits TCP Orientation limit TCP Speed limit TCP Force limit Robot Power limit Robot Momentum limit

Page 11: Ur gen iii

11

User manual Page 64

TÜV certificate

Page 12: Ur gen iii

12

Absolute encoders

True absolute encoders

No referencing needed at startup

No backup batteries

CB2 Traditional robot CB3

Encoder type Incremental Absolute True absolute

Referencing needed YES NO NO

Battery needed NO YES NO

Page 13: Ur gen iii

13

Additional I/O

16 digital in 8 general purpose inputs 8 configurable inputs

16 digital out 8 general purpose outputs 8 configurable outputs

Page 14: Ur gen iii

14

Additional I/O

Safety Control board

Replaces Masterboard (CB2) Hard-coded connectors Color coded slots

Page 15: Ur gen iii

15

Runtime improvements

Improved realtime performance Part of software re-written

Resume program after security stop Program execution will continue from where it stopped

Conveyor tracking Sampling time 40kHz (CB2: 125Hz)

Singularity Speed reduced around singularities, enabling robot to move through

singularities