uq-power diesel generator powered by kubota model:ke37 · uq-power diesel generators comply with...

5
Page 1,of 5 UQ-POWER DIESEL GENERATOR Powered by Kubota Model:KE37 *Silent Type Unit Shown Above kW/kVA 37.0 kW/kVA 33.0 kW/kVA 40.0 Hz/rpm 60 46.0 41.0 50.0 1800 V 208 120 A / / inches lbs inches lbs GENERAL DATA Prime Power Continuous Power Standby Power Frequency Voltage Current Connection Rated Power Factor Open TypeL×W×HOpen Type(Weight) Silent TypeL×W×HSilent Type(Weight) 140 3P 4W Series 0.8pf 2645 Available in the following voltages 120/208, 277/480, 120/240( both single and three phase) All data based on ISO 3046, altitude 1000m (361ft), barometric pressure 100kPa (29.53inHg), air temperature 25 (77° F), relative humidity 30%. Please contact UQ-Power for correct generator capacity selection when the load application can't meet with the standard reference. UQ-Power diesel generators comply with standards ISO8528ISO 14000ISO3046GB755BS5000VDE0530, ISO3046IEC34-1 All data is subject to change without notice. 66.94×40.75x54.5 1984 x56.7

Upload: others

Post on 12-Apr-2021

12 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: UQ-POWER DIESEL GENERATOR Powered by Kubota Model:KE37 · UQ-Power diesel generators comply with standards ISO8528,ISO 14000,ISO3046,GB755,BS5000,VDE0530, ... 4 configurable

Page 1,of 5

UQ-POWER DIESEL GENERATOR

Powered by Kubota Model:KE37

*Silent Type Unit Shown Above

kW/kVA 37.0

kW/kVA 33.0

kW/kVA 40.0

Hz/rpm 60

46.0

41.0

50.0

1800

V 208 120

A

/

/

inches

lbs

inches

lbs

GENERAL DATA

Prime Power Continuous

Power Standby Power

Frequency

Voltage

Current

Connection

Rated Power Factor

Open Type(L×W×H)

Open Type(Weight)

Silent Type(L×W×H)

Silent Type(Weight)

140

3P 4W Series

0.8pf

2645

■ Available in the following voltages 120/208, 277/480, 120/240( both single and three phase)■ All data based on ISO 3046, altitude 1000m (361ft), barometric pressure 100kPa (29.53inHg), air temperature 25 ℃(77°F), relative humidity 30%.

■ Please contact UQ-Power for correct generator capacity selection when the load application can't meet with the standardreference.■ UQ-Power diesel generators comply with standards ISO8528,ISO 14000,ISO3046,GB755,BS5000,VDE0530,ISO3046,IEC34-1

All data is subject to change without notice.

66.94×40.75x54.5

1984

98.43x43.31x56.7

Page 2: UQ-POWER DIESEL GENERATOR Powered by Kubota Model:KE37 · UQ-Power diesel generators comply with standards ISO8528,ISO 14000,ISO3046,GB755,BS5000,VDE0530, ... 4 configurable

All data is subject to change without notice.. Page 2,of 5

Brand new Kubota Diesel Engine, to include air filter, fuel filters, oil filter, starting motor and charging

Alternator YANAN SLG brushless AC alternator with Yanan YA460F or YA440

50℃, fan with protective shroud

Base mounted fuel tank, fuel meter, rubber anti-vibration pads, battery holder ≥500KW: channel steel base frame

Molded case circuit breaker (MCCB)

DEEP SEA 6020

Lead-acid battery, connection cables.

Flex exhaust, Elbow and flange, Exhaust silencer, etc.

UQ-Power standard,Mechanical drawing, electric drawing, operation & maintenance manual,

certification etc.

Engine accessories ◇ Heavy-duty air filter ◇Coolant heater ◇Lub oil heater ◇Fuel and Water Separator

◇50℃ radiator ◇Heat exchanger + water cooling tower + External water circulation pumpingsystem

◇Remote horizontal water tank system

◇Other(Comap controls inc)

◇2, 3 and 4 pole, thermo-magnetic

◇ATS- available in Nema 1 and 3R, 2 and 3 pole

◇Double wall tank available in 8, 12, and 24 hour sizes

www. u

q-po

wer.com

Engine

Alternator

Radiator

Base frame

Circuit Breaker Engine

Control System Start

Battery

Exhaust System

Documents

Cooling system

Control System

Circuit Breaker

Automatic Transfer Switch

Optional Fuel Tank Ⅱ . STANDARD

CONFIGURATION

Standard Unit Configuration

Optional available Equipment

Page 3: UQ-POWER DIESEL GENERATOR Powered by Kubota Model:KE37 · UQ-Power diesel generators comply with standards ISO8528,ISO 14000,ISO3046,GB755,BS5000,VDE0530, ... 4 configurable

All data is subject to change without notice. Page 3,of 5

48 kW

3.620 L

98x120 mm

23:1

1800 RPM

V3600

Aspirated Vertical in line

4

Mechanical Governor

3.18 gallns/hour at full Load

D(ASTMD975)

Bosch Type

■ Lubrication System

13.2 L NA l/h

CF 121 ℃

■ Coolant System

10 L 110 ℃

71 ℃

■ Air Intake System

Naturally Aspirated ≦ 1.96 kPa

■ Exhaust System

Single exhaust 7.07 kPa

■ Starting System

Electric start 80 Ah

ENGINE DATA Engine

Model

Aspiration Type

No. of Cylinders

Governor Type

■ FuelSystem ■ Prime power Fuelconsumption

Fuel #

Lub Oil Capacity

Lub #

Coolant Capacity

Std. Thermostat (Modulating) Range

Air intcke

Exhaust Gas Flow

Start Mode

Engine power

Displacement

Bore×Stroke

Compression Ratio

Rated Speed

www.uq-po

wer.com

Injection System

Lub Oil Consumption

Max.Temperature

Max. Top Tank Temp.

Air Pressure

Max.Back Pressure

Battery

Page 4: UQ-POWER DIESEL GENERATOR Powered by Kubota Model:KE37 · UQ-Power diesel generators comply with standards ISO8528,ISO 14000,ISO3046,GB755,BS5000,VDE0530, ... 4 configurable

All data is subject to change without notice. Page 4,of 5

ALTERNATOR DATA44/55 kW/kVA

208/120 V

60 Hz

CONTROL SYSTEM DATA MODEL DSE6020

■ Control Panel features

Electronic J1939 (CAN) and Modbus capable. MPU and alternator

sensing engine support for diesel,and gas engines all in one

controller. With a large number of flexible inputs, outputs and

protection circuits.

The modules can be easily adapted to suit a wide range of

applications.

■ Key Functions

▲Configurable remote start input▲utility voltage sensing

▲Generator/load power monitoring

▲Configurable staged loading

▲CAN, MPU and alternator

(kW, kV A, kV Ar, pf) speed sensing in one variant

▲alternative configuration

▲alarm including common alarm,common

▲Generator overload protection (kW) ▲3 engine maintenancealarms

electric and common shutdown

▲Efficient power save mode

▲mains and generator closed viafront panel

▲LCD and LED alarmindication

▲Configurable event log (50)

▲Heated display optionavailable

☆For more information, please visit the

▲4 configurable DC outputs

▲4 configurable analog./digitali nputs&s topping Deep Sea Controls website

▲6 configurable digital inputs

▲Support for 0-10 V & 4-20 mA oilpressure sensors

▲engine speed protection

▲Engine pre-heat

▲Multiple date and time scheduler

▲Engine idle control for starting

▲Fuel pump control

▲Battery voltage monitoring

▲Start on low battery voltage output

Single Bearing

IP21

80.70%

±1.0%

YN440

Alternator Model

PF.

Phase

Connection

Winding Pitch

Insulation Class

Tel. Influence

Harmonic

Coefficient Voltage

Adjust Scope

Yanan SLG224C

0.8

3

3P 4W,Y

connection 2/3

H/H

TIF:<50

THF:<2% ≥

±5%

Rate Power

Voltage

Frequency

Bearing

Proteccion

Class

Efficiency

Voltage

Regulation AVR

Excitation

System

Self-excited

www.uq-po

wer.com

Page 5: UQ-POWER DIESEL GENERATOR Powered by Kubota Model:KE37 · UQ-Power diesel generators comply with standards ISO8528,ISO 14000,ISO3046,GB755,BS5000,VDE0530, ... 4 configurable

All data is subject to change without notice, sorry for inform.

Page 5,of 5

WARRANTY POLICY

1.Standard warranty for one year or 1000 hours ( whichever comes first) from sales date.

Refer to

《UQ-Power Diesel Generator Warranty Manual》 for more details.

2.Maintenance parts( filters, belts,hoses, batteries),improper operation and maintenance

failures are excluded from the warranty policy

Ⅷ . DRAWING (for illustration purposes only)

www.uq-po

wer.com

0 0 0 0

e B

B

B

B

=

=

==

e e =

=

=

a0

0 0 0

00

00

0

0 0 0 0 .

98.43''