upper farm road appendix 1 - democratic.whitehorsedc.gov.uk

5
A016 Location and block plan Wrigley Associates 30 Alexandra Road Lyncombe Hill Bath BA2 4PW Tel: 01225 337420 Fax: 01225 337467 Far Field Antenna Test Facility Location and block plan Wrigley Associates 30 Alexandra Road Lyncombe Hill Bath BA2 4PW Tel: 01225 337420 Fax: 01225 337467 AL(0)A016 As existing Location and block plan September 2015 1.2500 @A3 Farfield Antenna Test Facility for Satellite Applications Catapult Wrigley Associates 30 Alexandra Road Lyncombe Hill Bath BA2 4PW Tel: 01225 337420 Fax: 01225 337467 1m 0 5m 10m 20m 50m 100m 1m 0 5m 10m 20m 50m 100m 1m 0 5m 10m 20m 50m 100m Location plan scale 1.2500 Upper Farm Road

Upload: others

Post on 18-Dec-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

A016

Location and block plan

Wrigley Associates

30 Alexandra Road

Lyncombe Hill

Bath BA2 4PW

Tel: 01225 337420

Fax: 01225 337467

Far Field Antenna Test

Facility

Location and block plan

Wrigley Associates

30 Alexandra Road

Lyncombe Hill

Bath BA2 4PW

Tel: 01225 337420

Fax: 01225 337467

AL(0)A016

As existing

Location and block plan

September 2015

1.2500 @A3

Farfield Antenna Test Facility

for Satellite Applications Catapult

Wrigley Associates

30 Alexandra Road

Lyncombe Hill

Bath BA2 4PW

Tel: 01225 337420

Fax: 01225 337467

1m

0

5m 10m 20m 50m 100m1m

0

5m 10m 20m 50m 100m1m

0

5m 10m 20m 50m 100m

Location plan scale

1.2500

U

p

p

e

r

F

a

r

m

R

o

a

d

simondunn-lwin
Typewritten Text
Appendix 1

5m

1:2000 Scale bar 200m @ A2

25m 50m 100m

South Car Park

Upper Farm

To Upper Farm Road

To R

oad

Fifte

en

Line of sight: cabin centres approx. 400m100mm buried duct to follow same line - Detail BA012 cross-section

Detail A

Detail A Scale 1:500

A011

Detail B Scale 1:10

500

Rx Storage Cabin

20' ISO ContainerCar Parking

Rx Storage Cage

Rx Tower & Cabin

Palisade Fence

See Note 1

A014

Earth coveringEarth to be backfilled

Turf to be removed, storedand reinstated

100mm duct

Power cable laid direct

Existing taxiway to be cleared ofvegatation overgrowth to provide access

where necessary

Upper Farm Road

Chilton Field

Transmit (Tx) Receive (Rx)

Warning tape

Revision Revision date Revision notes

21/08/2015 Moved storage cabins; comments; Upper Farm trees1

All rights reserved. Copyright Site One Ltd. 2015

COMMENTS

SHEET NO.

FINISH

TYPE

MATERIAL

PART NO.

SHEET SIZE

A2SCALE

CHECKED BY

DRAWN BY

18/08/2015DATE DRAWN

REVISION

PreliminaryISSUE

CLIENT NAME

DRAWING NO.

PROJECT NO.

20

P

20

12345678910111213141516171819

12345678910111213141516171819

A

B

C

D

E

F

G

H

J

K

L

M

N

Do not scale this drawing.1.All dimensions in mm 2.unless otherwise stated.All material to be grade 3.S275J0 or S355J0 (or J2), in compliance with BS 10025.All metalwork, including 4.fasteners, to be hot-dip galvanized to BS EN 1416.All fasteners to be 5.minimum grade 8.8, in compliance with BS 4190, and supplied with a square section spring washer and full nut.Minimum hole clearance 6.for fasteners should be 1mm greater than the nominal fastener diameter.No thermal cutting to be 7.used in process. All parts to be laser-cut where possible, including bolt holes. Laser-cutting is not a 'thermal-cutting' process.

Refer to drawing

A. Aljo

15058SAC

N/A

N/A

N/A

Unit 18 Notley Farm, Chearsley RoadLong Crendon, Aylesbury

BuckinghamshireHP18 9ER

United Kingdom

T: +44 (0) 1844 208 363E: [email protected]

1:2000

4

15058.COM.A010LAYOUT OF THE FAR FIELD TEST RANGETITLE

DESCRIPTION Easting

Rx TowerRx Storage CabinRx Storage Cage20' ISO ContainerCar ParkTx Cabin

Northing Latitude Longitude OS Grid

447762447771447771447771447757447409

185677185699185699185699185710185726

51.56794751.56814751.56814751.56814751.56825051.568418

-1.3123003-1.3121621-1.3121621-1.3121621-1.3123653-1.3173857

SU 47762 85677SU 47771 85699SU 47771 85699SU 47771 85699SU 47757 85710SU 47409 85726

Locations

Existing taxiway and hardstanding

Boundaries

Roads

Trees

Key

Buildings

Vehicle access

Line of sight

Palisade fencing

P

A

B

C

D

E

F

G

H

J

K

L

M

N

25/08/2015 Title changed; houses added; scale; sheet size2

04/09/2015 Tower pos'ns; extra detail view A014; extended path for Tx3

07/09/2015 Line of sight; duct detail; annotations4

simondunn-lwin
Distance Measurement
170.84 m
simondunn-lwin
Distance Measurement
100.07 m
simondunn-lwin
Distance Measurement
95.61 m
simondunn-lwin
Typewritten Text
Appendix 2

+122.6m

+132.5m

+122.6m

Approx. 400m

+122.6m

+132.5m

+122.6m

Ap

pro

x. 4

75

0

Detail Scale 1:200

5m

1:2000 Scale bar 200m @ A3

25m 50m 100m

Approx. 190-195m

All rights reserved. Copyright Site One Ltd. 2015

COMMENTS

SHEET NO.

FINISH

TYPE

MATERIAL

PART NO.

SHEET SIZE

A3

SCALE

CHECKED BY

DRAWN BY

18/08/2015

DATE DRAWN

REVISION

Preliminary

ISSUE

CLIENT NAME

DRAWING NO.

PROJECT NO.

20

P

20

P

1

2345678910111213141516171819

12345678910111213141516171819

A

B

C

D

E

F

G

H

J

K

L

M

N

A

B

C

D

E

F

G

H

J

K

L

M

N

Do not scale this drawing.1.All dimensions in mm2.unless otherwise stated.All material to be grade3.S275J0 or S355J0 (or J2), incompliance with BS10025.All metalwork, including4.fasteners, to be hot-dipgalvanized to BS EN 1416.All fasteners to be5.minimum grade 8.8, incompliance with BS 4190,and supplied with asquare section springwasher and full nut.Minimum hole clearance6.for fasteners should be1mm greater than thenominal fastenerdiameter.No thermal cutting to be7.used in process. All partsto be laser-cut wherepossible, including boltholes. Laser-cutting is nota 'thermal-cutting'process.

Refer to drawing

A. Aljo

15058SAC

N/A

N/A

N/A

Unit 18 Notley Farm, Chearsley Road

Long Crendon, Aylesbury

Buckinghamshire

HP18 9ER

United Kingdom

T: +44 (0) 1844 208 363

E: [email protected]

1:2000

Revision Revision date Revision notes

21/08/2015

Positioner; contoured to Chilton Field; scale change

1

3

LONG SECTION THROUGH THE RANGE

TITLE

DESCRIPTION

25/08/2015

Title; antenna pole; distances

2

15058.COM.A011

04/09/2015

Show increased distance; change in height

3

Tree Canopy average height approx. +140.0m

Approx. 75-80m

Approx. 75-80m Approx. 9m

5m

1:600 Scale bar 200m @ A3

25m 50m

Line of sight from upper window

Hidden from window view

Line of sight from person

Hidden from garden view

Key

+122.0m

All rights reserved. Copyright Site One Ltd. 2015

COMMENTS

SHEET NO.

FINISH

TYPE

MATERIAL

PART NO.

SHEET SIZE

A3

SCALE

CHECKED BY

DRAWN BY

18/08/2015

DATE DRAWN

REVISION

Preliminary

ISSUE

CLIENT NAME

DRAWING NO.

PROJECT NO.

20

P

20

P

1

2345678910111213141516171819

12345678910111213141516171819

A

B

C

D

E

F

G

H

J

K

L

M

N

A

B

C

D

E

F

G

H

J

K

L

M

N

Do not scale this drawing.1.All dimensions in mm2.unless otherwise stated.All material to be grade3.S275J0 or S355J0 (or J2), incompliance with BS10025.All metalwork, including4.fasteners, to be hot-dipgalvanized to BS EN 1416.All fasteners to be5.minimum grade 8.8, incompliance with BS 4190,and supplied with asquare section springwasher and full nut.Minimum hole clearance6.for fasteners should be1mm greater than thenominal fastenerdiameter.No thermal cutting to be7.used in process. All partsto be laser-cut wherepossible, including boltholes. Laser-cutting is nota 'thermal-cutting'process.

Refer to drawing

A. Aljo

15058SAC

N/A

N/A

N/A

Unit 18 Notley Farm, Chearsley Road

Long Crendon, Aylesbury

Buckinghamshire

HP18 9ER

United Kingdom

T: +44 (0) 1844 208 363

E: [email protected]

1:600

Revision Revision date Revision notes

21/08/2015

Sight line to windows; sight line to person; tower with antenna

1

3

X-SECTION TO SHOW VIEW FROM CHILTON FIELD

TITLE

DESCRIPTION

15058.COM.A012

25/08/2015 Title2

04/09/2015

Change distance of tower from trees to show pos'n change

3

1

2

1

2

34

34

5

5

Sites considered in the initial deployment of the Antenna test facility 6

6