update : joint mobile health and health care devices wg’s
DESCRIPTION
Update : Joint Mobile Health and Health Care Devices WG’s. Shared Use Cases (Health Care Device & Mobile Device ) ECG Holter Monitor Glucose Meter Telematics ( Automated Vehicle First Responder) Appendix: FHIR References. Shared Use Cases (Health Care Device & Mobile Device). - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: Update : Joint Mobile Health and Health Care Devices WG’s](https://reader034.vdocuments.us/reader034/viewer/2022051821/568166d5550346895ddae748/html5/thumbnails/1.jpg)
Update : Joint Mobile Health and Health Care Devices WG’s
Shared Use Cases (Health Care Device & Mobile Device)
• ECG Holter Monitor
• Glucose Meter
• Telematics ( Automated Vehicle First Responder)
• Appendix: FHIR References
![Page 2: Update : Joint Mobile Health and Health Care Devices WG’s](https://reader034.vdocuments.us/reader034/viewer/2022051821/568166d5550346895ddae748/html5/thumbnails/2.jpg)
Shared Use Cases (Health Care Device & Mobile Device)
• ECG Holter Monitor
• Glucose Meter
• Telematics ( Automated Vehicle And First Responder – FIHR Application )
![Page 3: Update : Joint Mobile Health and Health Care Devices WG’s](https://reader034.vdocuments.us/reader034/viewer/2022051821/568166d5550346895ddae748/html5/thumbnails/3.jpg)
Holter Monitor Test• Patient is due for Holter test in preparation for annual
checkup.• Patient elects to have remote Holter test from their
patient portal.• Patient receives Holter Monitor at home mail.• Patient reviews video on how to setup Holter test
monitor.• Patient is instructed to install Holter application on
their smart phone.• Patient applies Holter monitor device and sync device
with mobile device.3
![Page 4: Update : Joint Mobile Health and Health Care Devices WG’s](https://reader034.vdocuments.us/reader034/viewer/2022051821/568166d5550346895ddae748/html5/thumbnails/4.jpg)
Holter Monitor Test - continued
• Mobile device verifies that Holter Monitor is active and properly setup.
• Patient is given confirmation status ready.• Patient has been instructed to journal
activities while Holter monitor is active.• Patient accidently disconnect lead.• Patient reconnects lead and journals event
and verifies Holter monitor is back to ready.
4
![Page 5: Update : Joint Mobile Health and Health Care Devices WG’s](https://reader034.vdocuments.us/reader034/viewer/2022051821/568166d5550346895ddae748/html5/thumbnails/5.jpg)
Holter Monitor Test - continued
• After 24 hours of monitoring, mobile device indicates test completed.
• Mobile device indicates that test data is ready to upload to patient portal.
• Patient verifies upload to proceed and receives confirmation upon completion.
• Patient returns Holter monitor via mail.
5
![Page 6: Update : Joint Mobile Health and Health Care Devices WG’s](https://reader034.vdocuments.us/reader034/viewer/2022051821/568166d5550346895ddae748/html5/thumbnails/6.jpg)
Diabetes Management
EHR / PHR
Mobile AppSmart Phone/Tablet
Glucose MeterIEEE 11073
![Page 7: Update : Joint Mobile Health and Health Care Devices WG’s](https://reader034.vdocuments.us/reader034/viewer/2022051821/568166d5550346895ddae748/html5/thumbnails/7.jpg)
Glucose Monitor
• Patient is newly diagnosed with diabetes.• Patient has gone through a diabetes education
program and has chosen to use mobile diabetes application to assist in behavioral changes, journaling diet and activities.
• Glucose meter is paired to mobile device to facilitate exchange of data and journal with patient portal.
• Patient records glucose data, eating habits but has questions about how they are doing?
7
![Page 8: Update : Joint Mobile Health and Health Care Devices WG’s](https://reader034.vdocuments.us/reader034/viewer/2022051821/568166d5550346895ddae748/html5/thumbnails/8.jpg)
Glucose Monitor - continued
• Patient accesses their patient portal and seeks feedback from their care team.
• Care team request user to upload diabetes meter and journal data from mobile device.
• Care team reviews data and suggest changes to medication regiment.
• Mobile device can use alerts or reminders to better manage their medication and behavior.
8
![Page 9: Update : Joint Mobile Health and Health Care Devices WG’s](https://reader034.vdocuments.us/reader034/viewer/2022051821/568166d5550346895ddae748/html5/thumbnails/9.jpg)
Glucose Monitor - continued
• Patient learns through many iterations how to manage their diabetes effectively.
9
![Page 10: Update : Joint Mobile Health and Health Care Devices WG’s](https://reader034.vdocuments.us/reader034/viewer/2022051821/568166d5550346895ddae748/html5/thumbnails/10.jpg)
Diabetes Management Use Case
• User installs Mobile Application recommended by Care Team with access to Patient Portal (EHR).
• User defines relationships (Patients and Care Team).
• Mobile App gets Care Plan from EHR (Goals, Recommendations and Instructions).
![Page 11: Update : Joint Mobile Health and Health Care Devices WG’s](https://reader034.vdocuments.us/reader034/viewer/2022051821/568166d5550346895ddae748/html5/thumbnails/11.jpg)
Diabetes Management Use Case
• User pairs Glucose Meter (IEEE 11073 device).• User links device and sets patient context?• Glucose meter records glucose observations.• User/Patient syncs glucose meter with mobile
app and reviews data.
![Page 12: Update : Joint Mobile Health and Health Care Devices WG’s](https://reader034.vdocuments.us/reader034/viewer/2022051821/568166d5550346895ddae748/html5/thumbnails/12.jpg)
Diabetes Management Use Case
• User/Patient uploads recorded observations to EHR /PHR.
• Care team for reviews uploaded observations.• Care team modifies care plan based patient
uploaded data.• User/Patient receives alert that care plan has
been updated.
![Page 13: Update : Joint Mobile Health and Health Care Devices WG’s](https://reader034.vdocuments.us/reader034/viewer/2022051821/568166d5550346895ddae748/html5/thumbnails/13.jpg)
TAN-Interface
WAN
-Interface
LAN-Interface
PAN-Interface
HRN-Interface
Application Hosting Device
LAN Device
Scope
PAN Device
WAN DeviceHRN
Device
PAN DeviceTAN Device
Interface Teams define Certified Device Classes within constraints set by E2E Architecture, then select standards and create guidelines for these Certified Device ClassesE2E Architecture Team
Services Team: Focus on WAN and HRN IFs
Devices Team: Focus on PAN and LAN and TAN IFs
![Page 14: Update : Joint Mobile Health and Health Care Devices WG’s](https://reader034.vdocuments.us/reader034/viewer/2022051821/568166d5550346895ddae748/html5/thumbnails/14.jpg)
Next StepsHolter Monitors and Glucometers
• Identify current standards for interoperability.• Identify Patient / Device paring and matching.• Further define context specific use cases• Define FHIR resources in context of use case.• Explore current Continua Alliance capabilities• Develop Project Scope Statements• Identify Stakeholders
![Page 15: Update : Joint Mobile Health and Health Care Devices WG’s](https://reader034.vdocuments.us/reader034/viewer/2022051821/568166d5550346895ddae748/html5/thumbnails/15.jpg)
Telematics and Digital Health
Allen Hobbs, Ph.D.Co-Chair
HL7 Health DevicesDraft
01-23-24
![Page 16: Update : Joint Mobile Health and Health Care Devices WG’s](https://reader034.vdocuments.us/reader034/viewer/2022051821/568166d5550346895ddae748/html5/thumbnails/16.jpg)
Introduction
• Modern automobiles are becoming increasingly computerized with many components partially or entirely controlled by computers and networked both internally and externally.
• There are over 250 million registered passenger automobiles in the U.S.. Virtually all new automobiles are now computerized.
• The architecture is based on significant advances in safety (e.g. anti-lock brakes), fuel efficiency, and convenience.
• Increasing computerization also creates new risks to be addressed.
• Recent research has been focused on helping people enjoy the benefits of a computerized architecture while providing strong assurance of safety, security and privacy.
![Page 17: Update : Joint Mobile Health and Health Care Devices WG’s](https://reader034.vdocuments.us/reader034/viewer/2022051821/568166d5550346895ddae748/html5/thumbnails/17.jpg)
Digital I/O channels appearing on a modern car.
![Page 18: Update : Joint Mobile Health and Health Care Devices WG’s](https://reader034.vdocuments.us/reader034/viewer/2022051821/568166d5550346895ddae748/html5/thumbnails/18.jpg)
Intelligent Systems
![Page 19: Update : Joint Mobile Health and Health Care Devices WG’s](https://reader034.vdocuments.us/reader034/viewer/2022051821/568166d5550346895ddae748/html5/thumbnails/19.jpg)
Computerization also Creates New Risks
Recent research has been focused on helping people enjoy the benefits of a computerized architecture while providing strong assurance of safety, security and privacy.
Two papers exploring safety, security and privacy are worth noting here.
The first is the “Comprehensive Experimental Analysis of Automotive Attack Surfaces “ and the second is the “Experimental Security Analysis of a Modern Automobile”
• Comprehensive Experimental Analysis of Automotive Attack Surfaces, USENIX Security Symposium, August 2011
• Experimental Security Analysis of a Modern Automotive, IEEE Symposium on Security and Privacy, May 2010
![Page 20: Update : Joint Mobile Health and Health Care Devices WG’s](https://reader034.vdocuments.us/reader034/viewer/2022051821/568166d5550346895ddae748/html5/thumbnails/20.jpg)
Conclusion of Comprehensive Studies • Authors of the experimental studies note that automobile owners should
not be overly concerned about attacks to automotive architectures.
• Rather, they focus squarely on addressing potential automotive security and privacy issues that future cars will have – with even more sophisticated computer control and broader wireless connectivity.
• Security and privacy protections will need to be addressed for voice, data and location.
• For example, experimental analysis of remote exploit controls has found that an attacker who has compromised a automobiles’ telematics unit can record data from the in-cabin microphone (normally reserved for hands free calling) and exfiltrate data over the connected IRC channel.
• It is easy to capture the location of the automobile and track where a driver goes.
![Page 21: Update : Joint Mobile Health and Health Care Devices WG’s](https://reader034.vdocuments.us/reader034/viewer/2022051821/568166d5550346895ddae748/html5/thumbnails/21.jpg)
Next Steps• IEEE, the world's leading professional association for the advancement of
technology, announced the completion of IEEE 1616a, a new standard based on IEEE 1616, the first universal standard for motor vehicle event data recorders (MVEDRs), similar to units found on aircraft and trains.
• An adjunct to IEEE 1616, the new standard helps to provide greater consumer protections by improving the effectiveness of these automotive “black boxes” with new lockout functionality designed to prevent data tampering, such as Vehicle Identification Number (VIN) altering and odometer fraud. It also addresses concerns over privacy rights by establishing standards protecting data from misuse.
• Explore interface of IEEE 1616 with IEEE 11073 ( personal health devices ) , Interoperability Standards ( ICE ).
• Explore Autonomous Vehicle - First Responder Use Case Requirements
![Page 22: Update : Joint Mobile Health and Health Care Devices WG’s](https://reader034.vdocuments.us/reader034/viewer/2022051821/568166d5550346895ddae748/html5/thumbnails/22.jpg)
Emerging Trend
• Autonomous vehicles are predicted to be the norm by the year 2020 as automakers such as GM, Mercedes and BMW race to become technology leaders in the driverless vehicle market.
• Autonomous vehicles for First Responders will likely be an added value to Emergency Medicine
• Pilots studies are being conducted in California, Nevada and Florida
![Page 23: Update : Joint Mobile Health and Health Care Devices WG’s](https://reader034.vdocuments.us/reader034/viewer/2022051821/568166d5550346895ddae748/html5/thumbnails/23.jpg)
Self-Driving Cars: The Next Revolution
• In 2010, an estimated 86.3 percent of all workers 16 years of age and older commuted to work in a car, truck, or van, and 88.8 percent of those drove alone, while the remaining 11.2 percent traveled in a carpool.
• Congestion costs Americans 4.8 billion hours of time and 1.9 billion gallons of wasted fuel.
Self-driving cars: The next revolution kpmg.com | cargroup.org, 2013
![Page 24: Update : Joint Mobile Health and Health Care Devices WG’s](https://reader034.vdocuments.us/reader034/viewer/2022051821/568166d5550346895ddae748/html5/thumbnails/24.jpg)
Autonomous Vehicles
![Page 25: Update : Joint Mobile Health and Health Care Devices WG’s](https://reader034.vdocuments.us/reader034/viewer/2022051821/568166d5550346895ddae748/html5/thumbnails/25.jpg)
Autonomous Vehicle
![Page 26: Update : Joint Mobile Health and Health Care Devices WG’s](https://reader034.vdocuments.us/reader034/viewer/2022051821/568166d5550346895ddae748/html5/thumbnails/26.jpg)
Autonomous Vehicle
![Page 27: Update : Joint Mobile Health and Health Care Devices WG’s](https://reader034.vdocuments.us/reader034/viewer/2022051821/568166d5550346895ddae748/html5/thumbnails/27.jpg)
Benefits of Autonomous Vehicles
• Reduce high cost of traffic crashes and transportation infrastructure
• Reduce the millions of hours wasted in traffic jams.
• Convergence of sensor-based and connected-vehicle technologies will happen and will have a positive effect on the adoption of both systems
• Convergence will bring enhanced mobility and safety and reduced environmental impacts
![Page 28: Update : Joint Mobile Health and Health Care Devices WG’s](https://reader034.vdocuments.us/reader034/viewer/2022051821/568166d5550346895ddae748/html5/thumbnails/28.jpg)
Autonomous Vehicle and First Responder
![Page 29: Update : Joint Mobile Health and Health Care Devices WG’s](https://reader034.vdocuments.us/reader034/viewer/2022051821/568166d5550346895ddae748/html5/thumbnails/29.jpg)
Next StepsTelematics Use Case
• Identify current interoperability standards for First Responders
• Further define context specific use cases• Identify requirements for device interoperability
for Autonomous Vehicles for First Responders.• Define FHIR resources relative to use case.• Develop Project Scope Statements• Identify HL7 and Industry Stakeholders
![Page 30: Update : Joint Mobile Health and Health Care Devices WG’s](https://reader034.vdocuments.us/reader034/viewer/2022051821/568166d5550346895ddae748/html5/thumbnails/30.jpg)
Appendix
• FHIR Administrative• FHIR Infrastructure• FHIR Clinical
![Page 31: Update : Joint Mobile Health and Health Care Devices WG’s](https://reader034.vdocuments.us/reader034/viewer/2022051821/568166d5550346895ddae748/html5/thumbnails/31.jpg)
FHIR Administrative• Attribution
– Patient– RelatedPerson– Practitioner– Organization
• Resources– Device– Location– Substance– Group
• Workflow Management– Encounter– Alert– Supply– Order– OrderResponse
• Financial– Coverage
31
![Page 32: Update : Joint Mobile Health and Health Care Devices WG’s](https://reader034.vdocuments.us/reader034/viewer/2022051821/568166d5550346895ddae748/html5/thumbnails/32.jpg)
FHIR Infrastructure• Support
– List– Media– Other– DocumentReference– (Binary)
• Audit– Provenance– SecurityEvent
• Exchange– Document– Message– OperationOutcome– Query
• Conformance– Conformance– ValueSet– Profile
32
![Page 33: Update : Joint Mobile Health and Health Care Devices WG’s](https://reader034.vdocuments.us/reader034/viewer/2022051821/568166d5550346895ddae748/html5/thumbnails/33.jpg)
FHIR Clinical• General
– AdverseReaction– AllergyIntolerance– CarePlan– FamilyHistory– Condition– Procedure– Questionaire
• Medications– Medication– MedicationPrescription– MedicationAdministration– MedicationDispense– MedicationStatement– Immunization– ImmunizationProfile
33
![Page 34: Update : Joint Mobile Health and Health Care Devices WG’s](https://reader034.vdocuments.us/reader034/viewer/2022051821/568166d5550346895ddae748/html5/thumbnails/34.jpg)
FHIR Clinical - continued• Diagnostic
– Observation– DiagnosticReport– DiagnosticOrder– ImagingStudy– Specimen
• Device Interaction– DeviceCapabilities– DeviceLog– DeviceObservationReport
34