Page 1: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Experion MX R70x Release and Installation Notes

6510020594 Rev 02

Page 2: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes

November, 2018

Page 3: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Confidentiality Statement

This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection with Honeywell products. It is strictly prohibited to copy this manual or any part thereof or to transfer this manual or any part thereof to any non-Honeywell person or entity, except customer personnel for use in connection with Honeywell products. Persons employed by a third-party service company shall not have access to this manual.

Notice

All information and specifications contained in this manual have been carefully researched and prepared according to the best efforts of Honeywell, and are believed to be true and correct as of the time of this printing. However, due to continued efforts in product improvement, we reserve the right to make changes at any time without notice.

Trademarks

All trademarks and registered trademarks are the properties of their respective holders.

Copyright

© 2018 Honeywell

All rights reserved. No part of this publication may be reproduced or translated, stored in a database or retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of Honeywell.

Page 4: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection
Page 5: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

P/N 6510020594 Rev 02 11/22/18 i

Contents

Introduction ................................................................................................................................... v Audience ..................................................................................................................................... v About This Manual .................................................................................................................... vi Related Reading ......................................................................................................................... vi Conventions .............................................................................................................................. vii

1. System Requirements ............................................................................................................ 1-1 1.1. Hardware Requirements ................................................................................................ 1-1 1.2. Software Requirements ................................................................................................. 1-1

2. System Configuration ........................................................................................................... 2-1 2.1. QCS Security Guidelines .............................................................................................. 2-2

3. Installation Checklist ............................................................................................................ 3-1 3.1. QCS-Only System ......................................................................................................... 3-1

3.1.1. QCS Server ....................................................................................................... 3-2 3.1.2. Desktop Server .................................................................................................. 3-3 3.1.3. QCS Operator Station ....................................................................................... 3-4

3.2. Integrated QCS/Experion PKS Systems ....................................................................... 3-6 3.2.1. QCS Server ....................................................................................................... 3-6 3.2.2. Experion PKS Server ........................................................................................ 3-7 3.2.3. Integrated Operator Station ............................................................................... 3-8

3.3. Integrated QCS/PMD Systems...................................................................................... 3-9 3.3.1. QCS Server ..................................................................................................... 3-10 3.3.2. PMD Server..................................................................................................... 3-12 3.3.3. PMD Design Module ...................................................................................... 3-12 3.3.4. Integrated Operator Station ............................................................................. 3-12

3.4. Other Installations ....................................................................................................... 3-14 3.4.1. AllianceView .................................................................................................. 3-14

3.5. RAE R700.1 Solution pack Installation ...................................................................... 3-16

4. Installing SQL Server 2014 SP2 Client Software ............................................................... 4-1 4.1. Installing SQL Server 2014 SP2 Client Software ......................................................... 4-1

Page 6: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Contents

ii 11/22/18 P/N 6510020594 Rev 02

4.2. Installing Redirection Manager .................................................................................. 4-16 4.2.1. Summary of Installation Requirements .......................................................... 4-16

5. Install Remote Desktop Services .......................................................................................... 5-1

6. Install and Activate LabVIEW 2015 SP1 ........................................................................... 6-1 6.1. Installing LabVIEW 2015 SP1 ..................................................................................... 6-1 6.2. Installing LabVIEW 2015 SP1 f12 Patch ................................................................... 6-11 6.3. Install LABVIEW RT 2015 SP1 DEVICE DRIVER ................................................. 6-14

6.3.1. Install NI-VISA 15.5 drive ............................................................................. 6-14 6.3.2. Install NI-Serial RT ........................................................................................ 6-22

6.4. Activating LabVIEW 2015 SP1 ................................................................................. 6-25

7. Installing RAE R700.1 .......................................................................................................... 7-1 7.1. Installing RAE on a QCS Server .................................................................................. 7-1

7.1.1. Installing RAE R700.1 Experion PKS R500.1 Interface Components............. 7-1 7.1.2. Installing RAE R700.1 Base Media ................................................................ 7-23 7.1.3. Installing RAE R700.1 Support Media ........................................................... 7-32 7.1.4. Installing Experion MX MD Controls (optional) ........................................... 7-34 7.1.5. Installing Experion MX CD Controls (optional) ............................................ 7-34

7.2. Installing RAE on an Operator Station ....................................................................... 7-35 7.2.1. Installing RAE R700.1 Experion PKS R500.1 Interface Components........... 7-35 7.2.2. Installing RAE R700.1 Base Media ................................................................ 7-59 7.2.3. Installing Experion MX MD Controls (optional) ........................................... 7-67 7.2.4. Installing Experion MX CD Controls (optional) ............................................ 7-67

7.3. Installing Patches ........................................................................................................ 7-67 7.4. Obtaining a RAE License Key.................................................................................... 7-68

7.4.1. To obtain a temporary RAE license ................................................................ 7-68 7.4.2. To obtain a permanent RAE license ............................................................... 7-68

7.5. Installing RAE R700.1 Solution pack on Non-RAE Experion Nodes ....................... 7-70

8. Post-Installation Steps .......................................................................................................... 8-1 8.1. Copy the Product Manual CD files ............................................................................... 8-1 8.2. LabVIEW Mass Compilation ....................................................................................... 8-1 8.3. Internet Explorer ........................................................................................................... 8-3 8.4. Modifying the Configuration Settings of the Monitor Display .................................... 8-5

8.4.1. Modifying the Configuration Settings of the Monitor Display ........................ 8-5 8.4.1.1. Setting the Monitor Color Quality ............................................................... 8-5 8.4.1.2. Increasing the GDI Objects Quota ............................................................... 8-6

8.4.2. Uninstalling the Additional Display Drivers Installed by Third Party Applications .................................................................................................................. 8-8

8.5. Scanner Software .......................................................................................................... 8-9

Page 7: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Contents

P/N 6510020594 Rev 02 11/22/18 iii

9. Third Party Software ............................................................................................................ 9-1 9.1. Installing Other Third Party Software ........................................................................... 9-1

9.1.1. Microsoft Security Updates .............................................................................. 9-1 9.1.2. Installing Symantec Endpoint Protection .......................................................... 9-2 9.1.3. Installing McAfee Antivirus Software .............................................................. 9-3 9.1.4. Installing Adobe Reader.................................................................................... 9-3 9.1.5. HP Switch Firmware Updates ........................................................................... 9-4

10. Advisories ......................................................................................................................... 10-1 10.1. Stopping the Experion Performance Monitoring .................................................. 10-1 10.2. Links and I/O Point Names ................................................................................... 10-3 10.3. RAE Control Panel - Station startup and options ................................................. 10-3 10.4. Touch Screen with QCS Nodes ............................................................................ 10-4 10.5. Wide Screen Monitor with QCS Node ................................................................. 10-7

11. Glossary............................................................................................................................ 11-1

Page 8: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Contents

iv 11/22/18 P/N 6510020594 Rev 02

List of Tables Table 3-1 QCS-Only Server Installation Checklist ................................................................................. 3-3 Table 3-2 Desktop Server Installation Checklist ..................................................................................... 3-4 Table 3-3 QCS-Only Operator Station installation Checklist ................................................................. 3-5 Table 3-4 Integrated QCS Server installation checklist ........................................................................... 3-7 Table 3-5 Experion PKS Server installation checklist ............................................................................. 3-8 Table 3-6 Integrated QCS Operator Station installation checklist .......................................................... 3-9 Table 3-7 Integrated QCS Server installation checklist ......................................................................... 3-10 Table 3-8 Integrated QCS Operator Station installation checklist ........................................................ 3-13 Table 3-9 AllianceView installation Checklist ...................................................................................... 3-15 Table 3-10 RAE R700.1 Solution pack installation Checklist .............................................................. 3-16 Table 7-1 QCS Server Scenarios details .................................................................................................. 7-4 Table 7-2 QCS Server Scenarios details for QCS Base Media ............................................................. 7-31 Table 7-3 QCS Operator Station Scenarios details ................................................................................ 7-38 Table 7-4 QCS Server Scenarios details for RAE R700 Base Media ................................................... 7-65 Table 7-5 QCS Solution Pack installation scenarios details .................................................................. 7-72

Page 9: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

P/N 6510020594 Rev 02 11/22/18 v

Introduction

This guide describes the installation of RAE R700.1 for use with Experion PKS R500.1. The document covers the system requirements, installation checklists, and the installation procedures to complete the RAE installation.

The RAE R700.1 configuration procedures are covered in the Real-Time Application (RAE) R700.1 for Experion R500.1 Configuration and Maintenance Guide p/n 6510020594.

This document has references to these optional software applications, but does not describe their installation procedures:

• Experion MX MD controls

• Experion MX CD controls

This document is intended for usage on setting up the QCS node with fresh installation scenarios by using RAE R700.1 associated installation medias. For setting up QCS Server using other alternate scenarios like loading an image and rename the server using PCRename utility, you need to refer the Experion MX Computer Cloning User Guide p/n 6510020595.

Audience This manual is intended for anyone installing the RAE R700.1 software.

Page 10: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Introduction

11/22/18 P/N 6510020594 Rev 02 vi

About This Manual This manual contains 11 chapters;

Chapter 1: System Requirements provides the hardware and software requirements required to install RAE R700.

Chapter 2: System Configuration provides the system configuration supported for RAE R700.

Chapter 3: Installation Checklist provides a checklist, which lists the order in which the installation tasks needs to be performed to complete the installation for each of the QCS systems.

Chapter 4: Installing SQL Server 2014 SP2 Client Software provides instructions to install SQL 2008 Client software.

Chapter 5: Install Remote Desktop Services provides instructions to install the Experion PKS R500.1 software on various QCS nodes.

Chapter 6: Install and Activate LabVIEW 2015 SP1 provides instructions to install and activate LabVIEW 2015 SP1 and also provides instructions to install NI Device Driver for MPU Link.

Chapter 7: Installing RAE R700.1 provides instructions to install RAE R700.1 on QCS Server, Operator Station, AllianceView and Minimal RAE.

Chapter 8: Post-Installation Steps provides instructions on the tasks that you need to complete after the installation of RAE R700.1.

Chapter 9: Third Party Software provides information on the third party software that you need to install apart from the standard RAE installation.

Chapter 10: Advisories provides more information on specific content.

Chapter 11: Glossary provides the definition of the terms and acronyms used in this manual.

Related Reading The following documents contain related reading material.

Page 11: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Introduction Conventions

P/N 6510020594 Rev 02 11/22/18 vii

Honeywell P/N Document Title / Description

6537100023 PRODUCT MANUALS PDF COLLECTION 6510030220 PRODUCTION OF QCS DESKTOP SERVER OR OPERATOR

STATION ON WIN10 ENTERPRISE 64 BIT 6510030221 PRODUCTION OF QCS ONLY SERVER ON WINDOWS

SERVER 2016 (X64). 6510020590 Experion MX MD Controls R700.1 Software Change Notice 6510020591 Experion MX CD Controls R700.1 Software Change Notice EPDOC-X136-en-500 Experion Software Installation User’s Guide R500.1

EPDOC-X136-en-500

Experion PKS Software Installation User's Guide Release R500.1

EPDOC-X175-en-500

Experion PKS R500.1 Support Media Software - Software Change Notice

PMDOC-X136-en-900

Experion PKS with PMD Controller Software Installation User's Guide, Release R900.1

PMDOC-X206-en-900

Experion PKS with PMD Controller OPC Data Server Installation Guide, Release R900.1

51155348 Experion R500.1 PDF Collection DVD 6510020593 Real-Time Application Environment(RAE) R700.1 for Experion

PKS R500.1-Configuration and Maintenance Guide 6510020596 Experion MX Software Upgrade User Manual 6510020597 Experion MX Remote Desktop Services Installation and

Configuration Guide 6510020381 Experion MX EDAQ & MSS Systems Manual 6510020595 Experion MX Computer Cloning User Guide 6510020601 Experion MX HMIWeb User Guide

Conventions The following conventions are used in this manual:

Text may appear in uppercase or lowercase except as specified in these conventions. Boldface Boldface characters in this special type indicate your input. Special Type Characters in this special type that are not boldfaced indicate system prompts,

responses, messages, or characters that appear on displays, keypads, or as menu selections.

Italics In a command line or error message, words and numbers shown in italics represent filenames, words, or numbers that can vary; for example, filename represents any filename. In text, words shown in italics are manual titles, key terms, notes, cautions, or warnings.

Page 12: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Introduction

11/22/18 P/N 6510020594 Rev 02 viii

Boldface Boldface characters in this special type indicate button names, button menus, fields on a display, parameters, or commands that must be entered exactly as they appear.

Lowercase In an error message, words in lowercase are filenames or words that can vary. In a command line, words in lowercase indicate variable input.

Type Type means to type the text on a keypad or keyboard. Press Press means to press a key or a button. [ENTER] or [RETURN]

[ENTER] is the key you press to enter characters or commands into the system, or to accept a default option. In a command line, square brackets are included; for example: SXDEF 1 [ENTER]

[CTRL] [CTRL] is the key you press simultaneously with another key. This key is called different names on different systems; for example, [CONTROL], or [CTL].

[KEY-1]-KEY-2 Connected keys indicate that you must press the keys simultaneously; for example, [CTRL]-C.

Click Click means to position the mouse pointer on an item, then quickly depress and release the mouse button. This action highlights or “selects,” the item clicked.

Double-click Double-click means to position the mouse pointer on an item, and then click the item twice in rapid succession. This action selects the item “double-clicked.”

Drag X Drag X means to move the mouse pointer to X, then press the mouse button and hold it down, while keeping the button down, move the mouse pointer.

Press X Press X means to move the mouse pointer to the X button, then press the mouse button and hold it down.

The attention icon appears beside a note box containing information that is important.

The caution icon appears beside a note box containing information that cautions you about potential equipment or material damage.

The warning icon appears beside a note box containing information that warns you about potential bodily harm or catastrophic equipment damage.

Page 13: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

P/N 6510020594 Rev 02 11/22/18 1-1

1. System Requirements

This chapter provides the hardware and software requirements for installing RAE R700.

1.1. Hardware Requirements The hardware validated for the RAE R700.1 installation are:

• 24 GB RAM in Dell R330 and T330

• 24 GB RAM with RDIMM slot for R320 and T320

• 16 GB RAM for T5810XL Workstation

• 16 GB RAM for T3600XL Workstation

Hardware Requirements – QCS Web Displays Client

Any hardware with the following minimum specifications.

• Memory: 4GB or higher

• Video Memory: 1 GB or higher

• CPU: 2 cores or higher

• Frequency: 2.4 GHz or higher

1.2. Software Requirements None.

Page 14: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes System Requirements

11/22/18 P/N 6510020594 Rev 02 1-2

The installation instructions start with installation of the Operating System using the Experion PKS Initialization Media.

NOTE:

Only software applications and device drivers qualified by Honeywell for use on QCS computers should be installed. The installation of unqualified software applications or device drivers may result in product performance and reliability issues. Refer to chapter 9.1 for a list of software and drivers qualified as of the release of this manual. Refer to the QCS Compatibility Matrix in www.honeywellprocess.com for the most recent list of qualified applications and device drivers.

Page 15: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

P/N 6510020594 Rev 02 11/22/18 2-1

2. System Configuration

RAE R700.1 for Experion PKS R500.1 system supports the following system senarios:

• QCS-Only

• Integrated QCS / Experion PKS

• Integrated QCS / Experion PMD

The additional supported installations include:

• AllianceView

• Experion MX MD Controls

• Experion MX CD Controls

Page 16: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes System Configuration

11/22/18 P/N 6510020594 Rev 02 2-2

2.1. QCS Security Guidelines

The following are the security guidelines to be followed to ensure that the Experion MX /MX Proline is secure and reduce the possibilities of cyber attacks.

• Antivirus – Ensure that the latest antivirus package recommended by Honeywell is running on all the nodes.

• Locking USB ports – Ensure that USB ports are blocked physically or disabled when not in use.

• Changing passwords regularly – Ensure that passwords including Admin password are changed periodically to reduce any threat due to password being compromised.

• Not using default passwords – Ensure that no default passwords (if any) are used. They need to be changed after the system is setup.

• Using Honeywell recommended Whitelisting packages like Bit 9 or McAfee enhances the security of the processes running in the node. It allows only authorized processes to run on the node.

• Ensure that the access to the QCS nodes areas is restricted so that only authorized personnel can have access to these nodes.

• Ensure not to connect physical drives which do not have the latest antivirus update and security patches suggested by Honeywell, to any system.

• Ensure that SSL certificate is applied on the QCS Server node when using QCS Web displays for Zipline scanner template and for HMI Displays built using Experion MX HMIWeb Controls. Not using SSL certificates increases the vulnerability of the system to security attacks over the network.

• Ensure that logged on user in the QCS server during normal operations is QCSUser (product administrator) and not QCSAdmin (system administrator). Logging in as System Administrator during normal operations will greatly increase the vulnerability of the system to security attacks.

Page 17: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

P/N 6510020594 Rev 02 11/22/18 3-1

3. Installation Checklist

This chapter provides the installation checklists for RAE R700.1 software. It is important that you follow the sequence mentioned in the checklists when installing the software.

NOTE: It is assumed that you are installing RAE on a computer with a hard disk that can be reformatted.

Before starting installation ensure to have latest Product Manuals pdf Collection CD (P/N 6537100023) for latest released documents, If you do not have, then download the Product Manuals pdf Collection CD (P/N 6537100023) from \\Hps-bc35-vs05to\kview\PDF\65\3710\37100023\37100023.iso and burn this to a DVD.

NOTE: During installation user may encounter User Account Control dialog box, Acknowledge the user account control dialog box if it appears.

3.1. QCS-Only System The QCS-Only System is a standalone QCS System, with no DCS (Experion/Third party) integrated with it.

This section provides the checklists to install RAE on a QCS-Only system. The checklists in this section cover:

• QCS Server

• Desktop Server

• Operator Station

Page 18: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installation Checklist

11/22/18 P/N 6510020594 Rev 02 3-2

3.1.1. QCS Server To build a QCS Server for a QCS-Only system, you will need:

Software

• LabVIEW 2015 SP1

• LabVIEW 2015 f12 PATCH

• RAE R700.1 Interface Media

• RAE R700.1 Base Media

• RAE R700.1 Support media

• Experion MX MD Controls (optional)

• Experion MX CD Controls (optional)

Licenses

• LabVIEW 2015 SP1 License Serial Number

• RAE R700.1 License

• Remote Desktop Services License (optional)

Page 19: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installation Checklist QCS-Only System

P/N 6510020594 Rev 02 11/22/18 3-3

Hardware

DELL PowerEdge Server

Sequence of Tasks

Table 3-1 lists the tasks you must perform to install RAE. The tasks must be performed in sequential order.

Table 3-1 QCS-Only Server Installation Checklist

Task Refer Section Completed?

Install and Activate LabVIEW 2015 SP1 6

Installing RAE on a QCS Server 7.1

Installing RAE R700.1 Support Media 7.1.3

Install Remote Desktop Services (Optional) 5

Installing Experion MX MD Controls (optional) 7.1.4

Installing Experion MX CD Controls (optional) 7.1.5

Post-Installation Steps 8

Install Microsoft Security Updates 9.1.1

Installing Other Third Party Software 9.1

NOTE: After completing the tasks listed in Table 3-1, refer to the Real-Time Application Environment(RAE) R700.1 for Experion PKS R500.1- Configuration and Maintenance Guide p/n 6510020593 for the configuration procedures.

3.1.2. Desktop Server To build a Desktop Server for a QCS-Only system, you will need:

Software

• LabVIEW 2015 SP1

• LabVIEW 2015 f12 PATCH

• RAE R700.1 Interface Media

• RAE R700.1 Base Media

• RAE R700.1 Support media

Page 20: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installation Checklist

11/22/18 P/N 6510020594 Rev 02 3-4

• Experion MX MD Control (optional)

• Experion MX CD Control (optional)

Licenses

• LabVIEW 2015 SP1 License Serial Number

• RAE R700.1 License

Hardware

DELL Precision WorkStation

Sequence of Tasks

Table 3-2 lists the tasks you must perform to install RAE. The tasks must be performed in asequential order.

Table 3-2 Desktop Server Installation Checklist

Task Refer Section Completed?

Install and Activate LabVIEW 2015 SP1 6

Installing RAE on a QCS Server 7.1

Installing RAE R700.1 Support Media 7.1.3

Installing Experion MX MD Controls (optional) 7.1.4

Installing Experion MX CD Controls (optional) 7.1.5

Post-Installation Steps 8

Install Microsoft Security Updates 9.1.1

Installing Other Third Party Software 9.1

NOTE: After completing the tasks listed in Table 3-2, refer to Real-Time Application Environment(RAE) R700.1 for Experion PKS R500.1-Configuration and Maintenance Guide p/n 6510020593 for the configuration procedures.

3.1.3. QCS Operator Station To build a QCS Operator Station for a QCS-Only system, you will need:

Software

• LabVIEW 2015 SP1

Page 21: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installation Checklist QCS-Only System

P/N 6510020594 Rev 02 11/22/18 3-5

• LabVIEW 2015 f12 PATCH

• RAE R700.1 Interface Media

• RAE R700.1 Base Media

• RAE R700.1 Support media

• Experion MX MD Control (optional)

• Experion MX CD Control (optional)

Licenses

• LabVIEW 2015 SP1 License Serial Number

• RAE R700.1 License

Hardware

DELL Precision WorkStation

Sequence of Tasks

Table 3-3 lists the tasks you must perform to install RAE. The tasks must be performed insequential order.

Table 3-3 QCS-Only Operator Station installation Checklist

Task Refer Section Completed?

Installing SQL Server 2014 SP2 Client Software 4

Install and Activate LabVIEW 2015 SP1 6

Installing RAE on an Operator Station 7.2

Installing RAE R700.1 Support Media 7.1.3

Installing Experion MX MD Controls (optional) 7.2.3

Installing Experion MX CD Controls (optional) 7.2.4

Post-Installation Steps 8

Install Microsoft Security Updates 9.1.1

Installing Other Third Party Software 9.1

Touch Screen with QCS Nodes (Optional) 10.4

Page 22: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installation Checklist

11/22/18 P/N 6510020594 Rev 02 3-6

NOTES: After completing the tasks that are mentioned in Table 3-3, refer to Real-Time Application Environment(RAE) R700.1 for Experion PKS R500.1-Configuration and Maintenance Guide, p/n 6510020593 for the configuration procedures.

3.2. Integrated QCS/Experion PKS Systems In the Integrated QCS/Experion PKS systems, the QCS Server and the Experion PKS Server run on separate nodes. All QCS and DCS displays are accessible at the Integrated Operator Stations. This section provides the checklists required to install an Integrated QCS/Experion PKS System.

3.2.1. QCS Server To build a QCS Server for an integrated QCS/Experion PKS system, you will need:

Software

• LabVIEW 2015 SP1

• LabVIEW 2015 SP1 f12 Patch

• RAE R700.1 Interface Media

• RAE R700.1 Base Media

• RAE R700.1 Support media

• Experion MX MD Control (optional)

• Experion MX CD Control (optional)

Licenses

• LabVIEW 2015 SP1 License Serial Number

• RAE R700.1 License

• Remote Desktop Services License (optional)

Hardware

• DELL PowerEdge Server

Page 23: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installation Checklist Integrated QCS/Experion PKS Systems

P/N 6510020594 Rev 02 11/22/18 3-7

Sequence of Tasks

Table 3-4 lists the tasks that you must perform for installing RAE. The tasks are listed in the sequential order for installation.

Table 3-4 Integrated QCS Server installation checklist

Task Refer Section Completed?

Install and Activate LabVIEW 2015 SP1 6

Installing RAE on a QCS Server 7.1

Installing RAE R700.1 Support Media 7.1.3

Install Remote Desktop Services(optional) 5

Installing Redirection Manager (Optional) 4.2

Installing Experion MX MD Controls (optional) 7.1.4

Installing Experion MX CD Controls (optional) 7.1.5

Post-Installation Steps 8

Install Microsoft Security Updates 9.1.1

Installing Other Third Party Software 9.1

NOTES: After completing the tasks that are mentioned in Table 3-4, refer to Real-Time Application Environment(RAE) R700.1 for Experion PKS R500.1-Configuration and Maintenance Guide p/n 6510020593 for the configuration procedures.

3.2.2. Experion PKS Server

NOTES: Ensure to create the windows user “QCSAdmin” while installing the Operating System in Experion PKS Server. This “QCSAdmin” user has to be associated to the windows groups “Users”, “Administrators” and “Product Administrators”. Next login as QCSAdmin to install Experion PKS Software.

Refer to Software_Installation_Users_Guide_EPDOC-X136-en-500 Release R500.1 for the Expeiron PKS Server installation procedure.

Refer to Experion PKS R500.1 Support Media Software - Software Change Notice, p/n EPDOC-X175-en-500 for more details.

Page 24: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installation Checklist

11/22/18 P/N 6510020594 Rev 02 3-8

NOTES: Make sure to install the applicable Experion PKS patches on Experion PKS Server.

Table 3-5 Experion PKS Server installation checklist

Task Refer Section Completed?

RAE R700.1 Solution pack Installation (for Experion MX HMIWeb Controls)

3.5

3.2.3. Integrated Operator Station The Integrated Operator Station layers the QCS Operator Station software on to the existing Experion Flex and Console Operator Stations.

To build a QCS Operator Station for an Integrated QCS/Experion PKS system, you will need:

Software

• LabVIEW 2015 SP1

• LabVIEW 2015 SP1 f12 Patch

• RAE R700.1 Interface Media

• RAE R700.1 Base Media

• RAE R700.1 Support media

• Experion MX MD Control (optional)

• Experion MX CD Control (optional)

Licenses

• LabVIEW 2015 SP1 License Serial Number

• RAE R700.1 License

Hardware

• DELL Precision Workstation

Page 25: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installation Checklist Integrated QCS/PMD Systems

P/N 6510020594 Rev 02 11/22/18 3-9

NOTES: Integrated Op Stations require 16GB of RAM even though the DCS-only Op Stations only require 8GB of RAM.

Sequence of Tasks

Table 3-6 lists the tasks required to install RAE. The tasks must be performed in sequential order.

Table 3-6 Integrated QCS Operator Station installation checklist

Task Refer Section Completed?

Installing SQL Server 2014 SP2 Client Software 4

Install and Activate LabVIEW 2015 SP1 6

Installing RAE on an Operator Station 7.2

Installing RAE R700.1 Support Media 7.1.3

Installing Experion MX MD Controls (optional) 7.2.3

Installing Experion MX CD Controls (optional) 7.2.4

Post-Installation Steps 8

Install Microsoft Security Updatess 9.1.1

Installing Other Third Party Software 9.1

Touch Screen with QCS Nodes (Optional) 10.4

NOTES: After completing the tasks that are mentioned in Table 3-6, refer to Real-Time Application Environment(RAE) R700.1 for Experion PKS R500.1-Configuration and Maintenance Guide p/n 6510020593 for the configuration procedures.

3.3. Integrated QCS/PMD Systems In the Integrated QCS/PMD systems, the QCS Server and the PMD Server run on separate nodes. All QCS and PMD displays are accessible at the Integrated Operator Stations. QCS displays are not available on the PMD Server and PMD displays are not available on the QCS Server.

Note that in the Integrated QCS/PMD systems, all Operator Stations as well as the QCS Server use the localization database on the PMD Server for text string localization

This section provides the checklist to install an Integrated QCS/PMD System.

Page 26: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installation Checklist

11/22/18 P/N 6510020594 Rev 02 3-10

3.3.1. QCS Server To build a QCS Server for an integrated QCS/PMD system, you will need:

Software

• LabVIEW 2015 SP1

• LabVIEW 2015 SP1 f12 Patch

• RAE R700.1 Interface Media

• RAE R700.1 Base Media

• RAE R700.1 Support media

• Experion MX MD Control (optional)

• Experion MX CD Control (optional)

Licenses

• LabVIEW 2015 SP1 License Serial Number

• RAE R700.1 License

• Remote Desktop Services License (optional)

Hardware

• DELL PowerEdge Server

Sequence of Tasks

Table 3-7 lists the tasks that you must perform for installing RAE. The tasks are listed in the sequential order for installation.

Table 3-7 Integrated QCS Server installation checklist

Task Refer Section Completed?

Install and Activate LabVIEW 2015 SP1 6

Installing RAE on a QCS Server 7.1

Installing RAE R700.1 Support Media 7.1.3

Install Remote Desktop Services (optional) 5

Page 27: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installation Checklist Integrated QCS/PMD Systems

P/N 6510020594 Rev 02 11/22/18 3-11

Task Refer Section Completed?

Installing PMD OPC Data Sever

Experion PKS with PMD Controller OPC Data Server Installation Guide PMDOC-X206-en-900, Release R900.1

Installing Experion MX MD Controls (optional) 7.1.4

Installing Experion MX CD Controls (optional) 7.1.5

Post-Installation Steps 8

Install Microsoft Security Updates 9.1.1

Installing Other Third Party Software 9.1

Installing Redirection Manager 4.2

NOTES: After completing the tasks that are mentioned in Table 3-7, refer to Real-Time Application Environment(RAE) R700.1 for Experion PKS R500.1-Configuration and Maintenance Guide p/n 6510020593 to know the procedure to configure the QCS Server.

Page 28: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installation Checklist

11/22/18 P/N 6510020594 Rev 02 3-12

3.3.2. PMD Server

NOTES: Ensure to create the windows user “QCSAdmin” while installing the Operating System in PMD Server. This “QCSAdmin” user has to be associated to the windows groups “Users”, “Administrators” and “Product Administrators”. Next login as QCSAdmin to install Experion as well as PMD Software.

To know the steps to build the PMD Server, refer to Experion PKS with PMD Controller Software Installation User's Guide PMDOC-X136-en-900, Release R900.1.

NOTES: Make sure to install the applicable Experion PKS patches on PMD Server.

3.3.3. PMD Design Module

NOTES: Ensure to create the windows user “QCSAdmin” while installing the Operating System in PMD Design Module. This “QCSAdmin” user has to be associated to the windows groups “Users”, “Administrators” and “Product Administrators”. Next login as QCSAdmin to install PMD Software.

To know the steps to build the PMD Design Module, refer to Experion PKS with PMD Controller Software Installation User's Guide PMDOC-X136-en-900, Release R900.1.

3.3.4. Integrated Operator Station The Integrated Operator Station layers the QCS Operator Station software on to the existing Experion Flex and Console Operator Stations.

Ensure to create the windows user “QCSAdmin” while installing the Operarting System in Operator Station. This “QCSAdmin” user has to be associated to the windows groups “Users”, “Administrators” and “Product Administrators”. Next login as QCSAdmin to install Experion PKS and Experion PMD Software.

To build a QCS Operator Station for an Integrated QCS/PMD system, you need:

Software

• Microsoft SQL Server 2014 SP2 Standard DVD

• PMD System software installation media Release R900.1

Page 29: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installation Checklist Integrated QCS/PMD Systems

P/N 6510020594 Rev 02 11/22/18 3-13

• LabVIEW 2015 SP1

• LabVIEW 2015 SP1 f12 Patch

• RAE R700.1 Interface Media

• RAE R700.1 Base Media

• RAE R700.1 Support media

• Experion MX MD Control (optional)

• Experion MX CD Control (optional)

Licenses

• LabVIEW 2015 SP1 License Serial Number

• RAE R700.1 License

Hardware

• DELL Precision Workstation

NOTES: Integrated Op Stations require 16GB of RAM even though the DCS-only Op Stations only require 8GB of RAM.

Sequence of Tasks

Table 3-8 lists the tasks that you must perform for installing RAE. The tasks are listed in the sequential order for installation.

Table 3-8 Integrated QCS Operator Station installation checklist

Task Refer Section Completed?

Install PMD HMI Flex station

Experion PKS with PMD Controller Software Installation User's Guide PMDOC-X136-en-900, Release R900.1

Installing SQL Server 2014 SP2 Client Software 4

Install and Activate LabVIEW 2015 SP1 6

Installing RAE on an Operator Station 7.2

Page 30: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installation Checklist

11/22/18 P/N 6510020594 Rev 02 3-14

Task Refer Section Completed?

Installing RAE R700.1 Support Media 7.1.3

Installing Experion MX MD Controls (optional) 7.2.3

Installing Experion MX CD Controls (optional) 7.2.4

Post-Installation Steps 8

Install Microsoft Security Updates 9.1.1

Installing Other Third Party Software 9.1

Touch Screen with QCS Nodes(Optional) 10.4

NOTES: After completing the tasks that are mentioned in Table 3-8, refer to Real-Time Application Environment(RAE) R700.1 for Experion PKS R500.1-Configuration and Maintenance Guide p/n 6510020593 for the configuration procedures.

3.4. Other Installations This section provides checklists for other RAE R700.1 installs.

3.4.1. AllianceView To build an AllianceView, you will need:

Software

• LabVIEW 2015 SP1

• LabVIEW 2015 SP1 f12 Patch

• RAE R700.1 Interface Media

• RAE R700.1 Base Media

• RAE R700.1 Support media

• Experion MX MD Control (optional)

• Experion MX CD Control (optional)

Licenses

Page 31: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installation Checklist Other Installations

P/N 6510020594 Rev 02 11/22/18 3-15

• LabVIEW 2015 SP1 License Serial Number

• RAE R700.1 AllianceView License

• Remote Desktop Services License

Hardware

• DELL PowerEdge Server

Sequence of Tasks

Table 3-9 lists the tasks required to install RAE. The tasks must be performed in sequential order.

Table 3-9 AllianceView installation Checklist

Task Refer Section Completed?

Installing SQL Server 2014 SP2 Client Software 4

Install and Activate LabVIEW 2015 SP1 6

Installing RAE on an Operator Station 7.2

Installing RAE R700.1 Support Media 7.1.3

Install Remote Desktop Services 5

Installing Experion MX MD Controls (optional) 7.2.3

Installing Experion MX CD Controls (optional) 7.2.4

Post-Installation Steps 8

Install Microsoft Security Updates 9.1.1

Installing Other Third Party Software 9.1

NOTES:

After completing the tasks that are mentioned in Table 3-9 , refer to Real-Time Application Environment(RAE) R700.1 for Experion PKS R500.1-Configuration and Maintenance Guide, p/n 6510020593 for the configuration procedures.

To know the procedure to install and configure the Remote Desktop Services, refer to Experion MX Remote Desktop Services Installation and Configuration Guide p/n 6510020597.

Page 32: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installation Checklist

11/22/18 P/N 6510020594 Rev 02 3-16

3.5. RAE R700.1 Solution pack Installation This section provides checklists for RAE R700.1 Solution pack installation on Non-RAE Experion nodes (Experion Flex node, Experion Console, Experion Server Redundant and Non-Redundant nodes).

NOTE: RAE R700.1 Solution pack installation is not supported for the feature called Custom Install Paths (CIP) on Experion R500.1 nodes.

Table 3-10 RAE R700.1 Solution pack installation Checklist

Task Refer Section Completed?

Installing RAE R700.1 Solution pack on Non-RAE Experion Nodes (for Experion MX HMIWeb Controls) 7.5

Page 33: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

P/N 6510020594 Rev 02 11/22/18 4-1

4. Installing SQL Server 2014 SP2 Client Software

4.1. Installing SQL Server 2014 SP2 Client Software

To install SQL 2014 SP2 Client Software, perform the following:

1. Insert SQL Server 2014 SP2 DVD into CD/DVD drive.

The AutoPlay window appears.

2. Double-click the Run SETUP.EXE.

3. If the setup window does not launch automatically, perform the following:

4. Browse to the root folder in the CD/DVD drive.

Page 34: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing SQL Server 2014 SP2 Client Software

11/22/18 P/N 6510020594 Rev 02 4-2

5. Double-click the setup.exe.

If the User Account Control dialog box appears Click Yes.

The SQL Server Installation Center window appears.

6. Click Installation on the left pane, and click New SQL Server stand-alone installation or add features to an existing installation from the right pane.

Page 35: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installing SQL Server 2014 SP2 Client Software Installing SQL Server 2014 SP2 Client Software

P/N 6510020594 Rev 02 11/22/18 4-3

The Product Key dialog box appears.

Page 36: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing SQL Server 2014 SP2 Client Software

11/22/18 P/N 6510020594 Rev 02 4-4

7. Product key will be taken by default, Click Next.

The License Terms dialog box appears.

Page 37: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installing SQL Server 2014 SP2 Client Software Installing SQL Server 2014 SP2 Client Software

P/N 6510020594 Rev 02 11/22/18 4-5

8. Read through the license agreement, and then select I accept the license terms.

9. Click Next.

The Global Rules dialog box appears.

Page 38: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing SQL Server 2014 SP2 Client Software

11/22/18 P/N 6510020594 Rev 02 4-6

10. Click Next.

The Microsoft Update dialog box appears.

Page 39: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installing SQL Server 2014 SP2 Client Software Installing SQL Server 2014 SP2 Client Software

P/N 6510020594 Rev 02 11/22/18 4-7

11. Ensure that Use Microsift Update to check for updates is not selected and the click Next.

The Product Updates dialog box appears.

Page 40: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing SQL Server 2014 SP2 Client Software

11/22/18 P/N 6510020594 Rev 02 4-8

12. Click Next.

The Install Rules dialog box appears.

Page 41: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installing SQL Server 2014 SP2 Client Software Installing SQL Server 2014 SP2 Client Software

P/N 6510020594 Rev 02 11/22/18 4-9

13. Click Next.

The Setup Role dialog box appears.

Page 42: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing SQL Server 2014 SP2 Client Software

11/22/18 P/N 6510020594 Rev 02 4-10

14. Select SQL Server Feature Instalaltion and then click Next.

The Feature Selection window appears.

Page 43: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installing SQL Server 2014 SP2 Client Software Installing SQL Server 2014 SP2 Client Software

P/N 6510020594 Rev 02 11/22/18 4-11

15. From the Shared Features, select all the check boxes for all the items in the Shared Features except Reporting Services – SharePoint, Reporting Services Add-in for SharePoint Products, Distributed Replay Controller and Distributed Replay Client.

16. Click Next.

17. The Feature Rules dialog box appears

18. Click Next

The Server Configuration window appears.

Page 44: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing SQL Server 2014 SP2 Client Software

11/22/18 P/N 6510020594 Rev 02 4-12

19. Click Next.

The Ready to Install window appears.

Page 45: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installing SQL Server 2014 SP2 Client Software Installing SQL Server 2014 SP2 Client Software

P/N 6510020594 Rev 02 11/22/18 4-13

20. Click Install.

The Installation Progress window appears displaying the status of the installation.

Page 46: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing SQL Server 2014 SP2 Client Software

11/22/18 P/N 6510020594 Rev 02 4-14

21. Click Next.

Page 47: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installing SQL Server 2014 SP2 Client Software Installing SQL Server 2014 SP2 Client Software

P/N 6510020594 Rev 02 11/22/18 4-15

NOTE:

During Installation Progress if you get Microsoft SQL Server 2012 Native Client pop up window perform the following steps:

1. Insert Experion PKS installation DVD1.

2. Under Use Source field, browse SQL Native Client software from the path E:\Packages\Microsoft\SQL Native Client.

3. Click OK.

After the SQL Server 2014 SP2 setup completes, the following SQL Server 2014 SP2 installation Complete window appears.

Page 48: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing SQL Server 2014 SP2 Client Software

11/22/18 P/N 6510020594 Rev 02 4-16

22. Click Close.

23. Close the SQL Server Installation Center window.

4.2. Installing Redirection Manager Redirection Manager (RDM) must be installed on the QCS Server, when a redundant Experion PKS Server pair is integrated.

RDM enables QCS Server’s OPC client to transparently redirect requests to an alternate OPC Server. Redirection occurs whenever the RDM detects a failure in the active server. The QCS Server’s OPC client connects to the RDM instead of connecting to the primary OPC Server. The RDM supports connection to HCI/OPC server pairs hosted on Experion PKS and TPS platforms.

4.2.1. Summary of Installation Requirements Install the following components on the QCS Server to implement Redirection Manager:

Page 49: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installing SQL Server 2014 SP2 Client Software Installing Redirection Manager

P/N 6510020594 Rev 02 11/22/18 4-17

The Redirection manager package contains:

• System Management Runtime

• HCI Runtime components

• Redirection Manager

The (Optional) System Management Display package contains:

• System Management Display

NOTE: Honeywell recommends that you install the System Management Display. Without System Management Display, you might have difficulties determining the status of the Experion PKS server pair. If you choose to install the System Management Display, it enables you can access the RDM Auxiliary Status Display.

Perform the following steps to install the Redirection Manager:

1. Logon into Windows as the QCSAdmin user.

2. Insert the Experion PKS Installation DVD p/n 51155890-500 into the CD/DVD drive.

The AutoPlay window appears.

3. Double-click setup.exe.

If the setup window is not launched automatically, perform the following:

• Browse to the root folder of the CD/DVD drive.

• Double-click the setup.exe.

If the User Account Control dialog box appears.

4. Click Continue.

The Setup type of Node to install dialog box appears.

Page 50: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing SQL Server 2014 SP2 Client Software

11/22/18 P/N 6510020594 Rev 02 4-18

5. Select Optional Features.

6. Click Next.

The User and License Information dialog box appears.

Page 51: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installing SQL Server 2014 SP2 Client Software Installing Redirection Manager

P/N 6510020594 Rev 02 11/22/18 4-19

7. Verify the Customer Information and select Do not Install Software for Do you want to Install Licensed features?, select No for Are there Licensed TPS Components to install?

8. Click Next.

9. The Installation Path(s) Selection dialog box appears.

10. Click Next.

The Feature and Option Selection dialog box appears.

Page 52: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing SQL Server 2014 SP2 Client Software

11/22/18 P/N 6510020594 Rev 02 4-20

11. Select Custom as the Experion PKS Installation Option. Select the following from the list of applications to be installed.

• Redirection Manager

NOTE: Features(s) in Bold were already installed. Redirection Manager requires System Management Runtime and HCI Runtime. Ensure they are already installed.

12. Click Next.

The Security Password Entry dialog box appears.

Page 53: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installing SQL Server 2014 SP2 Client Software Installing Redirection Manager

P/N 6510020594 Rev 02 11/22/18 4-21

13. Type a security password and click Next.

The Experion Accounts Password Entry dialog box appears.

Page 54: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing SQL Server 2014 SP2 Client Software

11/22/18 P/N 6510020594 Rev 02 4-22

14. Type a strong password for all the accounts created during installation. For each of the applicable account, in the Password and Confirm Password boxes, type the password.

Page 55: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installing SQL Server 2014 SP2 Client Software Installing Redirection Manager

P/N 6510020594 Rev 02 11/22/18 4-23

NOTE:

Password for the accounts must adhere to the following rules.

• Must not contain the user’s account name or parts of the user’s full name that exceed two consecutive characters.

• Must be minimum of 6 characters and maximum 32 characters in length.

• Must begin with an alphabet and the must be in uppercase.

• Must contain characters from three of the following four categories.

– English uppercase characters (A through Z).

– English lowercase characters (a through z).

– Base 10 digits (0 through 9).

– Non-alphabetical characters (- @ # $ % ^ & + = ' ~ ! * ( ) _ + = { }\\ | : ; " < >, . ? /). Space is also a non-alphabetical character.

• Passwords of local accounts must be configured to be the same on all nodes in the Experion nodes.

• Ensure that you do not use the \ (back slash) for passwords in your Experion account.

15. Click Next.

The Summary dialog box appears. Review and read through the summary of selection made and click Install.

Page 56: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing SQL Server 2014 SP2 Client Software

11/22/18 P/N 6510020594 Rev 02 4-24

The Experion PKS – Status Display dialog box displays the list of components that are installed together with their status of installation.

Page 57: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installing SQL Server 2014 SP2 Client Software Installing Redirection Manager

P/N 6510020594 Rev 02 11/22/18 4-25

After the installation is complete, a message box appears indicating The installs have completed.

16. Remove the installation media from the CD-DVD drive.

17. Click Yes to restart the computer.

After the computer is started, logon to the computer as QCSAdmin user.

Page 58: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection
Page 59: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

P/N 6510020594 Rev 02 11/22/18 5-1

5. Install Remote Desktop Services

It is mandatory to install the Windows Remote Desktop Services on the AllianceView products. However, it is optional to install the Windows Remote Desktop Services on the QCS Server for the following systems:

• QCS- Only system

• Integrated QCS/Experion PKS system

To know the procedure to install the Remote Desktop Services and activation of license, refer to section 2 in Experion MX Remote Desktop Services Installation and Configuration Guide p/n 6510020597.

NOTE: After the installation of Remote Desktop Services is completed, refer to section 4.6 in Experion MX Remote Desktop Services Installation and Configuration Guide, p/n 6510020597 to know the procedure to create the user account for Remote Desktop clients.

Page 60: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection
Page 61: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

P/N 6510020594 Rev 02 11/22/18 6-1

6. Install and Activate LabVIEW 2015 SP1

This chapter provides instructions to install and activate LabVIEW 2015 SP1.

6.1. Installing LabVIEW 2015 SP1 To install the LabVIEW 2015 SP1, perform the following:

Log on to the computer as QCSAdmin user.

1. Insert the S/W MEDIA FOR LABVIEW 2015, p/n 6543210129 into the CD/DVD drive.

2. Perform the following if the auto run fails:

• Browse to the root folder of the DVD drive.

• Double-click autorun.exe.

The following LabVIEW 2015 SP1 window appears.

Page 62: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Install and Activate LabVIEW 2015 SP1

11/22/18 P/N 6510020594 Rev 02 6-2

3. Click Install LabVIEW, Modules, and Toolkits link.

The following LabVIEW 2015 SP1 dialog box appears.

Page 63: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Install and Activate LabVIEW 2015 SP1 Installing LabVIEW 2015 SP1

P/N 6510020594 Rev 02 11/22/18 6-3

4. Click Next.

The Select Installation option dialog appears.

Page 64: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Install and Activate LabVIEW 2015 SP1

11/22/18 P/N 6510020594 Rev 02 6-4

5. Click I have serial numbers for one or more products in this installer.

6. Clear the Select and activate products based on my serial numbers (Internet connection required) check box.

7. Click Next.

The Product List dialog box appears.

8. Click on VI Package Manager and select Do not install.

9. Click on NI SignalExpress and select Do not install.

10. Click on Device Drivers and select Do not install.

Page 65: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Install and Activate LabVIEW 2015 SP1 Installing LabVIEW 2015 SP1

P/N 6510020594 Rev 02 11/22/18 6-5

11. Click on LabVIEW English (Base/Full/Professional).

Page 66: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Install and Activate LabVIEW 2015 SP1

11/22/18 P/N 6510020594 Rev 02 6-6

12. Click Next.

The Product Information dialog box appears.

13. Clear the Search for important messages and updates on the National Instruments…. check box.

Page 67: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Install and Activate LabVIEW 2015 SP1 Installing LabVIEW 2015 SP1

P/N 6510020594 Rev 02 11/22/18 6-7

14. Click Next.

The User Information dialog box appears.

15. Type the Full Name, and Organization details in the respective fields.

16. Click Next.

The Serial Numbers dialog box appears.

Page 68: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Install and Activate LabVIEW 2015 SP1

11/22/18 P/N 6510020594 Rev 02 6-8

17. Find the Serial Number from the license agreement document and enter it in Serial Number field. Leave the Application Builder, Report Generation Toolkit and Database Toolkit Serial Number blank.

NOTE:

LabVIEW installs the Application Builder, Report Generation Toolkit and Database Toolkit when you install LabVIEW but it remains deactivated. If you plan to use the Application Builder, Report Generation Toolkit and Database Toolkit then you need to use the LabVIEW Professional Development System License. If you use the LabVIEW Base Package or Full Development System license then you must purchase and activate the Application Builder, Report Generation Toolkit and Database Toolkit separately.

18. Click Next.

The Destination Directory dialog box appears.

19. The default location where the LabVIEW 2015 SP1 is installed is displayed.

20. Click Next.

Page 69: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Install and Activate LabVIEW 2015 SP1 Installing LabVIEW 2015 SP1

P/N 6510020594 Rev 02 11/22/18 6-9

The License Agreement for National Instrument… dialog box appears.

21. Select I accept the above License Agreement and Click Next.

The License Agreement for Microsoft Software… dialog box appears.

22. Select I accept the above 2 License Agreement(s).

23. Click Next.

NOTE: If LabVIEW is being installed in Desktop Server or Operator Station, Disable Window fast Startup dialog box appears.

For the default installation, Check Disable Windows fast startup to prevent problems with installing or removing hardware box and Click Next.

The Start Installation dialog box appears.

24. Review the summary before starting the installation. If you want to make any changes, click Back, to go to the respective page, to make changes. If you do not want to make any changes, click Next.

25. The LabVIEW 2015 SP1 installation begins. The LabVIEW 2015 SP1 – Status Display dialog box displays the overall progress.

NOTE: If WARNING: Windows Firewall Might Be Enabled dialog box appears, then click Next.

After the installation is complete, the Installation Summary dialog box appears.

Page 70: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Install and Activate LabVIEW 2015 SP1

11/22/18 P/N 6510020594 Rev 02 6-10

26. Click Next.

The National Instruments dialog box appears.

27. Select No, I do not want to participate in the NI Customer…...

28. Click OK.

A message box appears prompting you to restart the computer.

Page 71: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Install and Activate LabVIEW 2015 SP1 Installing LabVIEW 2015 SP1 f12 Patch

P/N 6510020594 Rev 02 11/22/18 6-11

29. Remove the LabVIEW 2015 SP1 media from the CD/DVD drive and Click Yes to restart the computer.

6.2. Installing LabVIEW 2015 SP1 f12 Patch To install the LabVIEW 2015 SP1 f12 Patch, perform the following:

Log on to the computer as QCSAdmin user.

1. Insert the LV2015SP1_f12patch media, p/n 6543210135 into the CD/DVD drive.

2. Browse to the root folder of the DVD drive.

3. Double-click setup.exe.

The NI LabVIEW 2015 SP1 f12 Patch dialog box appears.

4. Click Next. Then Product Notifications dialog appears.

Page 72: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Install and Activate LabVIEW 2015 SP1

11/22/18 P/N 6510020594 Rev 02 6-12

5. Clear the Search for important messages and updates on the National Instruments…. check box.

6. Click Next. Then License Agreement dialog appears.

7. Select I accept the License Agreement.

8. Click Next.

Page 73: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Install and Activate LabVIEW 2015 SP1 Installing LabVIEW 2015 SP1 f12 Patch

P/N 6510020594 Rev 02 11/22/18 6-13

The Start Installation dialog appears.

9. Click Next. The LabVIEW 2015 SP1 f12 Patch installation begins. Then Installation dialog box displays the overall progress of installation. Installation takes few minutes to complete.

After the installation is complete. The Installation Complete dialog appears.

10. The Installation Complete dialog appears, click Next >>

Page 74: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Install and Activate LabVIEW 2015 SP1

11/22/18 P/N 6510020594 Rev 02 6-14

11. Click Finish.

The restart prompt appears.

12. Click Restart.

After the computer restarts, logon to Windows as the QCSAdmin user.

6.3. Install LABVIEW RT 2015 SP1 DEVICE DRIVER

If the MPU links are used, then the LabVIEW RT 2015 SP1 NI-VISA 15.5 drive and NI-Serial 3.6 device driver must be installed.

6.3.1. Install NI-VISA 15.5 drive To install the NI-VISA 5.0 drive.

1. Logon to the computer as the QCSAmin user..

2. Insert the LabVIEW 2015 reference driver media, p/n 6543210129 into the CD/DVD-ROM drive.

3. Click Run autorun.exe

The NI Device Drivers setup dialog box appears.

Page 75: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Install and Activate LabVIEW 2015 SP1 Install LABVIEW RT 2015 SP1 DEVICE DRIVER

P/N 6510020594 Rev 02 11/22/18 6-15

4. Click Install Software.

The National Instruments Device Drivers dialog box appears indicating the progress of Installer initialization.

The Features dialog box appears.

5. Click the drop-down arrow beside Data Acquisition, and then select Do not install this feature.

6. Expand Instrument Control and perform the following:

• Click the drop-down arrow beside NI-488.2 15.5, and then select Do not install this feature.

Page 76: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Install and Activate LabVIEW 2015 SP1

11/22/18 P/N 6510020594 Rev 02 6-16

• Click the drop-down arrow beside NI-Serial 15.0, and then select Install this feature and its subfeatures to a local drive.

Page 77: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Install and Activate LabVIEW 2015 SP1 Install LABVIEW RT 2015 SP1 DEVICE DRIVER

P/N 6510020594 Rev 02 11/22/18 6-17

7. Expand Instrument Control NI-VISA 15.5 Configuration Support.

8. Click the drop-down arrow beside PXI Configuration, and then select Do not install this feature.

Page 78: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Install and Activate LabVIEW 2015 SP1

11/22/18 P/N 6510020594 Rev 02 6-18

9. Expand Instrument Control NI-VISA 15.5 Run Time Support and perform the following:

• Click the drop-down arrow beside PXI, and then select Do not install this feature.

Page 79: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Install and Activate LabVIEW 2015 SP1 Install LABVIEW RT 2015 SP1 DEVICE DRIVER

P/N 6510020594 Rev 02 11/22/18 6-19

10. Expand Instrument Control NI-VISA 15.5 Development Support and perform the following:

• Click the drop-down arrow beside Examples, and then select Do not install this feature.

• Click the drop-down arrow beside Driver Development, and then select Do not install this feature.

• Click the drop-down arrow beside LabVIEW 2015 32- bit Support, and then select Do not install this feature.

11. Click Next to continue.

The Product Notifications Dialog Box appears.

Page 80: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Install and Activate LabVIEW 2015 SP1

11/22/18 P/N 6510020594 Rev 02 6-20

12. Uncheck the tick mark from check box and click Next to continue.

After the Installer initialization is complete, the Product Information dialog box appears.

13. Click Next.

The National Instruments Software License Agreement dialog box appears.

14. Click I accept the above 2 License Agreement.

Page 81: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Install and Activate LabVIEW 2015 SP1 Install LABVIEW RT 2015 SP1 DEVICE DRIVER

P/N 6510020594 Rev 02 11/22/18 6-21

The Driver Software Installation dialog box appears.

15. Click Next.

The Start Installation dialog box appears.

16. Click Next.

The installation screen appears indicating the installation progress.

NOTE: When installation is in progress, system ask for next media. Browse and select the next media and click OK.

After the installation is complete, the Installation Complete dialog box appears.

17. Click Next.

The National Instruments Device Drivers dialog box appears prompting you to restart the computer.

Page 82: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Install and Activate LabVIEW 2015 SP1

11/22/18 P/N 6510020594 Rev 02 6-22

18. Click Restart.

19. After the computer restarts, remove the CD from the CD/DVD-ROM drive.

6.3.2. Install NI-Serial RT To install the NI-Serial RT drive:

1. Logon to the computer with local administrative privileges.

2. Insert the LabVIEW 2015 reference drive media p/n 6543210129 into the CD/DVD-ROM drive.

3. Open the Windows Explorer.

4. Browse to the E:\Products\NI-VISA_RT folder.

Page 83: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Install and Activate LabVIEW 2015 SP1 Install LABVIEW RT 2015 SP1 DEVICE DRIVER

P/N 6510020594 Rev 02 11/22/18 6-23

5. Double-click NIVISAlvrt.msi.

The NI-VISA 15.5.0 for LabVIEW Real-Time Setup welcome wizard dialog box appears.

6. Click Next.

The End-User License Agreement dialog box appears.

7. Check I accept the terms in the License Agreement and click Next.

The Custom Setup dialog box appears.

8. Click Next.

The Ready to Install NI-VISA for LabVIEW Real-Time dialog box appears.

9. Click Install.

After the installation is completes, the NI-VISA 15.5.0 for LabVIEW Real-Time Setup installation successful dialog box appears.

10. Click Finish.

Page 84: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Install and Activate LabVIEW 2015 SP1

11/22/18 P/N 6510020594 Rev 02 6-24

After the NI-VISA 5.0 for LabVIEW Real-Time Setup installation is complete, open the Windows Explorer.

11. Browse to the E:\products\NI-Serial_RT folder.

12. Double-click SerialRT.msi.

The NI-Serial 15.0 for LabVIEW Real-Time Setup welcome wizard dialog box appears with Software License Agreement.

Page 85: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Install and Activate LabVIEW 2015 SP1 Activating LabVIEW 2015 SP1

P/N 6510020594 Rev 02 11/22/18 6-25

13. Select I accept the terms in the License Agreement and click Install.

14. If the User Account Control Dialog box appears. Click Yes to continue.

The Ready to Install the Application dialog box appears.

After the installation is complete, the NI-Serial 15.0 for LabVIEW Real-Time Setup installation successful dialog box appears.

15. Click Finish.

16. Remove the CD from the CD/DVD-ROM drive.

6.4. Activating LabVIEW 2015 SP1 Perform the following steps to activate the LabVIEW 2015 SP1.

1. Choose Start > National Instruments> NI License Manager.

2. Click Activate Products to enable the LabVIEW activation.

The Welcome to the National Instruments Activation Wizard dialog box appears.

Page 86: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Install and Activate LabVIEW 2015 SP1

11/22/18 P/N 6510020594 Rev 02 6-26

NOTE: There are several ways to do the activation. In this section instructions are provided to activate the LabVIEW using a Web browser.

3. Select Use a Web browser, email client, telephone, or fax machine to acquire an activation code and then click Next.

The How do you want to communicate with National Instruments to acquire an activation code? dialog box appears.

Page 87: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Install and Activate LabVIEW 2015 SP1 Activating LabVIEW 2015 SP1

P/N 6510020594 Rev 02 11/22/18 6-27

4. Click Use a Web browser on this or another computer and then click Next.

If already enter the serial number, the following dialog box appears.

If you have not entered the serial nuber during LabVIEW installation, it will ask you to enter the serial number for the products you want to activate. Enter the serial number and click Next.

Page 88: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Install and Activate LabVIEW 2015 SP1

11/22/18 P/N 6510020594 Rev 02 6-28

5. Make a note of the Product/Serial Number and Computer ID.

For security reasons, use a different computer to connect to the following National Instruments website: http://ni.com/activate.

The NI Product Activation page appears.

6. Select LabVIEW from the Product drop-down list.

Page 89: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Install and Activate LabVIEW 2015 SP1 Activating LabVIEW 2015 SP1

P/N 6510020594 Rev 02 11/22/18 6-29

7. Select 2015 SP1 from the Product Version drop-down list and enter the following details:

• Serial Number

• Computer ID

• First Name

• Last Name

• Organization

• Email Address

8. Click Submit.

The Activation code is displayed. Record the activation code or print the Activation Verification e-mail that is sent to the specified email address.

9. Start LabVIEW again on the target node and then click Activate.

10. Select Apply a 20-character activation code previously acquired for this computer and then click Next.

Page 90: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Install and Activate LabVIEW 2015 SP1

11/22/18 P/N 6510020594 Rev 02 6-30

11. Type the activation code and then click Next.

The Product Successfully Activated! message appears.

12. Click Finish.

The LabVIEW 2015 SP1 is activated. Make a note of the activation code information and save in the system where you are activating the LabVIEW, so that it can be used for reactivating the LabVIEW on the same computer, if needed.

Page 91: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

P/N 6510020594 Rev 02 11/22/18 7-1

7. Installing RAE R700.1

The chapter provides the procedure to install the RAE R700.1 software.

7.1. Installing RAE on a QCS Server This section provides the steps to install the RAE R700.1 software on a QCS Server.

The following medias are required to install RAE R700.1 software on a QCS Server.

• Media RAE R700.1 Experion PKS R500.1 Interface Components, p/n 6543210126

• Media RAE R700.1 Base Components, p/n 6543210127

The RAE R700.1 Experion PKS R500.1 Interface Components DVD provides the software components that are required to interface with the Experion PKS R500.1 software and needs to be installed before installing the RAE R700.1 Base Components.

7.1.1. Installing RAE R700.1 Experion PKS R500.1 Interface Components

Perform the following steps to install the RAE R700.1 Experion PKS R500.1 Interface Components.

1. Log on to the computer as QCSAdmin user.

Page 92: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing RAE R700.1

11/22/18 P/N 6510020594 Rev 02 7-2

2. Insert the RAE R700.1 Experion PKS R500.1 Interface Components DVD, p/n 6543210126 into the computer’s CD/DVD drive.

The AutoPlay window appears.

3. Double-click the Run setup.exe.

4. If the setup window does not launch automatically, perform the following:

• Browse to the root folder in the CD/DVD drive.

• Double-click the setup.exe.

• User Account Control dialog box appears.

• Click Yes.

The Welcome to the InstallShield Wizard for RAE R700.1 for Experion PKS R500.1 Interface Components dialog box appears.

5. Click Next.

Page 93: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installing RAE R700.1 Installing RAE on a QCS Server

P/N 6510020594 Rev 02 11/22/18 7-3

The Installation Type Selection dialog box appears.

6. Select the QCS Server option.

7. Click Next.

The QCS Server Scenarios dialog box appears.

Page 94: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing RAE R700.1

11/22/18 P/N 6510020594 Rev 02 7-4

8. Select the appropriate QCS Server installation scenario.

For most installations the Perform Experion configurations for QCS? check box should be selected. If you need to manually configure Experion for some reason, then clear this check box.

NOTE: For more information on the Experion configuration steps that are bypassed when you choose to manually configure Experion, refer to section 8.1 of Real-Time Application Environment(RAE) R700.1 for Experion PKS R500.1-Configuration and Maintenance Guide p/n 6510020593.

9. Proceed with the corresponding installation step by referring the below table.

Table 7-1 QCS Server Scenarios details

QCS Server Scenarios Steps to be follow

QCS Only Scenario: Step 10

Integrated QCS Server with Non Redundant Experion PKS Server Scenario

Step 11

Page 95: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installing RAE R700.1 Installing RAE on a QCS Server

P/N 6510020594 Rev 02 11/22/18 7-5

QCS Server Scenarios Steps to be follow

Integrated QCS Server with Redundant Experion PKS Server Scenario: Step 12

Integrated QCS Server with Non Redundant Experion PMD Server Scenario: Step 13

Integrated QCS Server with Redundant Experion PMD Server Scenario: Step 14

10. QCS Only Scenario:

• Select QCS-Only in the QCS Server Scenarios dialog box.

• Click Next.

The Installation Details dialog box appears.

Page 96: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing RAE R700.1

11/22/18 P/N 6510020594 Rev 02 7-6

Verify the details to ensure that it matches your requirements.

• Click Install to proceed with the installation.

• Go to Step 15.

11. Integrated QCS Server with Non Redundant Experion PKS Server Scenario:

• Select Integrated in the QCS Server Scenarios dialog box.

Page 97: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installing RAE R700.1 Installing RAE on a QCS Server

P/N 6510020594 Rev 02 11/22/18 7-7

• Click Next.

The Experion Version Selection dialog box appears.

Page 98: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing RAE R700.1

11/22/18 P/N 6510020594 Rev 02 7-8

• Select Experion PKS and click Next.

The Experion PKS Information dialog box appears.

Page 99: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installing RAE R700.1 Installing RAE on a QCS Server

P/N 6510020594 Rev 02 11/22/18 7-9

• Enter the Experion PKS Server Name.

• Click Next.

The Installation Details dialog box appears.

Page 100: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing RAE R700.1

11/22/18 P/N 6510020594 Rev 02 7-10

Verify the details to ensure that it matches your requirements.

• Click Install to proceed with the installation.

• Go to Step 15.

12. Integrated QCS Server with Redundant Experion PKS Server Scenario:

• Select Integrated in the QCS Server Scenarios dialog box.

Page 101: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installing RAE R700.1 Installing RAE on a QCS Server

P/N 6510020594 Rev 02 11/22/18 7-11

• Click Next.

The Experion Version Selection dialog box appears.

Page 102: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing RAE R700.1

11/22/18 P/N 6510020594 Rev 02 7-12

• Select Experion PKS

• Select Are you connecting to redundant servers (check for yes)? check box

• Click Next.

The Experion PKS Information dialog box appears.

Page 103: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installing RAE R700.1 Installing RAE on a QCS Server

P/N 6510020594 Rev 02 11/22/18 7-13

• Enter the following:

• Experion PKS Server A Name

• Experion PKS Server B Name

• Click Next.

The Installation Details dialog box appears.

Page 104: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing RAE R700.1

11/22/18 P/N 6510020594 Rev 02 7-14

Verify the details to ensure that it matches your requirements.

• Click Install to proceed with the installation.

• Go to Step 15.

13. Integrated QCS Server with Non Redundant Experion PMD Server Scenario:

• Select Integrated in the QCS Server Scenarios dialog box.

Page 105: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installing RAE R700.1 Installing RAE on a QCS Server

P/N 6510020594 Rev 02 11/22/18 7-15

• Click Next.

The Experion Version Selection dialog box appears.

Page 106: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing RAE R700.1

11/22/18 P/N 6510020594 Rev 02 7-16

• Select Experion PMD and click Next.

The Experion PMD Server Information dialog box appears.

Page 107: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installing RAE R700.1 Installing RAE on a QCS Server

P/N 6510020594 Rev 02 11/22/18 7-17

• Enter the following:

• Experion PMD Server Name: Type the Windows computer name of the Experion PMD Server.

• Backup SQL Server Name: This specifies the connection to the backup server for using local language database if the connection to local language database fails in the primary server. Type the Windows computer name of the Experion PMD Server.

• Click Next.

The Installation Details dialog box appears.

Page 108: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing RAE R700.1

11/22/18 P/N 6510020594 Rev 02 7-18

Verify the details to ensure that it matches your requirements.

• Click Install to proceed with the installation.

• Go to Step 15.

14. Integrated QCS Server with Redundant Experion PMD Server Scenario:

• Select Integrated in the QCS Server Scenarios dialog box.

Page 109: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installing RAE R700.1 Installing RAE on a QCS Server

P/N 6510020594 Rev 02 11/22/18 7-19

• Click Next.

The Experion Version Selection dialog box appears.

Page 110: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing RAE R700.1

11/22/18 P/N 6510020594 Rev 02 7-20

• Select Experion PMD

• Select Are you connecting to redundant servers (check for yes)? check box

• Click Next.

The Experion PMD Server Information dialog box appears.

Page 111: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installing RAE R700.1 Installing RAE on a QCS Server

P/N 6510020594 Rev 02 11/22/18 7-21

• Enter the following:

• Floating IP Address: Floating IP of the Redundant PMD server.

• Experion PMD Server A Name: Type the Windows computer name of the Redundant Experion PMD Server A.

• Experion PMD Server B Name: Type the Windows computer name of the Redundant Experion PMD Server B.

• Backup SQL Server Name: Type the Floating IP of the Redundant PMD Server.

• Click Next.

The Installation Details dialog box appears.

Page 112: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing RAE R700.1

11/22/18 P/N 6510020594 Rev 02 7-22

Verify the details to ensure that it matches your requirements.

• Click Install to proceed with the installation.

• Go to Step 15.

15. Installtion begins and Setup Status dialog box appears indicating the installation progress. This portion of the install will take around three minutes to complete.

Once the installation completed, The InstallShield Wizard Complete dialog box appears.

Page 113: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installing RAE R700.1 Installing RAE on a QCS Server

P/N 6510020594 Rev 02 11/22/18 7-23

16. Select the option Yes, I want to restart my computer now.

17. After the Experion PKS Interface Component installation is completed, remove the RAE R700.1 Experion PKS R500.1 Interface Components DVD.

18. Click Finish.

19. After the computer restarts, login to Windows as the QCSAdmin user.

The RAE R700.1 Experion PKS R500.1 Interface setup automatically completes the installation.

7.1.2. Installing RAE R700.1 Base Media Perform the following steps to install the RAE R700.1 Base Media.

1. Insert the RAE R700.1 Base Components DVD, p/n 6543210127, into the computer’s CD/DVD drive.

The AutoPlay window appears.

2. Double-click the Run RAESetup.exe.

Page 114: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing RAE R700.1

11/22/18 P/N 6510020594 Rev 02 7-24

3. If the setup window does not launch automatically, perform the following:

• Browse to the root folder in the CD/DVD drive.

• Double-click the RAESetup.exe.

The Welcome to the InstallShield Wizard for RAE 700 Base Components dialog box appears.

4. Click Next.

The Installation Type Selection dialog box appears.

Page 115: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installing RAE R700.1 Installing RAE on a QCS Server

P/N 6510020594 Rev 02 11/22/18 7-25

5. Select the QCS Server option.

6. Click Next.

The Navigation Bar and Station Selection Type Select dialog box appears.

Page 116: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing RAE R700.1

11/22/18 P/N 6510020594 Rev 02 7-26

7. Select the required navigation bar style.

NOTE: You must select one of the two navigation bar styles before proceeding with the installation.

8. Select one or both check boxes for station types (Is a Metals Application, Is a MultiMonitor System) where the navigation bar style must be applied.

Example: If you select the Horizontal (Best for Standard monitors) option and the Is a Metals Application check box, the horizontal navigational style is applied on the user interface of the Metals application.

9. Click Next.

The QCS Server Scenarios dialog box appears.

Page 117: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installing RAE R700.1 Installing RAE on a QCS Server

P/N 6510020594 Rev 02 11/22/18 7-27

10. Select the appropriate QCS Server scenario option.

For most installations the Perform Experion configurations for QCS? check box should be selected. If you need to manually configure Experion for some reason, then clear this check box.

NOTE: For more information on the Experion configuration steps that are bypassed when you choose to manually configure Experion, refer to section 8.1 of Real-Time Application Environment(RAE) R700.1 for Experion PKS R500.1-Configuration and Maintenance Guide p/n 6510020593.

11. Click Next.

The QCS Accounts Creation and Password Entry dialog box appears.

Page 118: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing RAE R700.1

11/22/18 P/N 6510020594 Rev 02 7-28

12. Click Next.

The Prompt for Password Change dialog boxes appears.

13. Type the password for QCSUser username and then click OK.

The Prompt for Password Change dialog boxes appears.

14. Type the password for Operator username and then click OK.

The Alter SQL Login dialog box appears.

15. Type the Password for HMXReadOnly username and then click OK.

The License Administrator dialog box appears.

For more information on how to obtain license see section 7.4.

16. Type the License Key details.

17. Click Install Key.

A message box appears confirming the successful installation of the license key.

18. Click OK.

The Installation Details dialog box appears.

Page 119: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installing RAE R700.1 Installing RAE on a QCS Server

P/N 6510020594 Rev 02 11/22/18 7-29

19. Verify the details, and then click Install. The Windows Powershell script runs and completes the installation automatically. This portion of the RAE install will take about 15 minutes to complete.

After the installation is complete, the InstallShield Wizard Complete dialog box appears.

Page 120: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing RAE R700.1

11/22/18 P/N 6510020594 Rev 02 7-30

20. Select the option Yes, I want to restart my computer now.

21. After the RAE Base Components installation is complete, remove the RAE Base Components DVD.

22. Click Finish.

23. After the computer restarts, logon to Windows as the QCSAdmin user.

The Credentials for DCOM RAE OPC Server dialog box appears.

24. Type the password of QCSAdmin and click OK.

The Credentials for DCOM RAE AE Server dialog box appears.

25. Type the password of mngr user and click OK.

26. The Windows PowerShell window appears.

27. Type the QCS Server Name and press [ENTER].

28. To enter details for Is SSL Certificate Installed on QCS Server? refer below table.

Page 121: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installing RAE R700.1 Installing RAE on a QCS Server

P/N 6510020594 Rev 02 11/22/18 7-31

Table 7-2 QCS Server Scenarios details for QCS Base Media

QCS Server Scenarios Inputs

QCS Only scenario Enter N

Integrated QCS Server with Redundant/Non Redundant Experion PKS Server scenario Enter Y

Integrated QCS Server with Redundant/Non Redundant Experion PMD Server scenario Enter Y

NOTE: Step 29 through Step 34 is applicable only for Integrated QCS Server with Windows 10 operating system.

29. Click Start > Windows PowerShell.

30. Right-click on Windows PowerShell and select Run as administrator.

31. Type cd "C:\ProgramData\Honeywell\Experion MX\ResourceKit\Setups\Misc\QcsWebDeploymentScripts" and press [ENTER].

32. Type .\Build-EndPointInfo.ps1 and press [ENTER].

33. Enter QCS Server Name and press [ENTER].

34. To enter details for Is SSL Certificate Installed on QCS Server? refer Table 7-4 .

Page 122: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing RAE R700.1

11/22/18 P/N 6510020594 Rev 02 7-32

The RAE R700.1 Base Componenets setup automatically completes the installation.

7.1.3. Installing RAE R700.1 Support Media Perform the following steps to install the RAE R700.1 Support Media.

1. Insert the RAE R700.1 Support Components DVD, p/n 6543210134, into the computer’s CD/DVD drive.

The AutoPlay window appears.

2. Double-click the Run Setup.exe.

3. If the setup window does not launch automatically, perform the following:

• Browse to the root folder in the CD/DVD drive.

• Double-click the Setup.exe.

The RAE 700 Support Media InstallShield Wizard progress bar appears.

The Install Option dialog box appears.

Page 123: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installing RAE R700.1 Installing RAE on a QCS Server

P/N 6510020594 Rev 02 11/22/18 7-33

4. Click Install the Support Media Now.

The Files in Use dialog box may appears.

5. Click OK.

The Installation Complete – Restart Windows dialog box appears.

Page 124: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing RAE R700.1

11/22/18 P/N 6510020594 Rev 02 7-34

6. Select Yes, I want to restart my computer now and then click OK.

7. After restart, The Base line command window appears and the RAE Support Components setup automatically completes the installation.

7.1.4. Installing Experion MX MD Controls (optional)

For more information on installing the R700.1 Experion MX MD Controls, refer to the document Experion MX MD Controls R700.1 Software Change Notice- p/n 6510020590.

7.1.5. Installing Experion MX CD Controls (optional)

For information about installing Experion MX CD Controls, refer to the document Experion MX CD Controls R700.1 Software Change Notice- p/n 6510020591.

Page 125: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installing RAE R700.1 Installing RAE on an Operator Station

P/N 6510020594 Rev 02 11/22/18 7-35

7.2. Installing RAE on an Operator Station This section provides the steps to install the RAE R700.1 software on an Operator Station. You should follow the same procedure to install RAE R700.1 on the AllianceView.

You will need the following media to install RAE R700.1 software on an Operator Station.

• Media RAE R700.1 Experion PKS R500.1 Interface Components, p/n 6543210126

• Media RAE R700.1 Base Components, p/n 6543210127

• Media RAE R700.1 Support Components DVD, p/n 6543210134

The RAE R700.1 Experion PKS R500.1 Interface Components DVD provides the software components required to interface with the Experion PKS R500.1 software.

7.2.1. Installing RAE R700.1 Experion PKS R500.1 Interface Components

Perform the following steps to install RAE R700.1 Experion PKS R500.1 Interface Components.

1. Logon to the computer as QCSAdmin user.

2. Insert the RAE R700.1 Experion PKS R500.1 Interface Components DVD, p/n 6543210126 into the computer’s CD/DVD drive.

The AutoPlay window appears.

3. Double-click Run setup.exe.

4. If the setup does not launch automatically, perform the following:

• Browse to the root folder of the CD/DVD drive.

• Double-click the setup.exe.

Page 126: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing RAE R700.1

11/22/18 P/N 6510020594 Rev 02 7-36

The Welcome to the InstallShield Wizard for RAE R700 for Experion PKS R500 Interface Components welcome dialog box appears.

5. Click Next.

The Installation Type Selection dialog box appears.

Page 127: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installing RAE R700.1 Installing RAE on an Operator Station

P/N 6510020594 Rev 02 11/22/18 7-37

6. Select QCS Operator Station option. This is also the correct option for the AllianceView.

7. Click Next.

The QCS Operator Station Scenarios dialog box appears.

Page 128: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing RAE R700.1

11/22/18 P/N 6510020594 Rev 02 7-38

8. Select the required QCS Operator Station Scenarios option.

9. Proceed with the corresponding installation step by referring the below table.

Table 7-3 QCS Operator Station Scenarios details

QCS Operator Station Scenarios Steps to be follow

QCS Only Operator Station Scenario: Step 10

Integrated Operator Station for Integrated QCS Server with Non Redundant Experion PKS Server Scenario: Step 11

Integrated Operator Station for Integrated QCS Server with Redundant Experion PKS Server Scenario: Step 12

Integrated Operator Station for Integrated QCS Server with Non Redundant Experion PMD Server Scenario: Step 13

Integrated Operator Station for Integrated QCS Server with Redundant Experion PMD Server Scenario: Step 14

10. QCS Only Operator Station Scenario:

• Select QCS-Only in the QCS Operator Station Scenarios dialog box.

Page 129: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installing RAE R700.1 Installing RAE on an Operator Station

P/N 6510020594 Rev 02 11/22/18 7-39

• Click Next.

The QCS Server Information dialog box appears.

Page 130: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing RAE R700.1

11/22/18 P/N 6510020594 Rev 02 7-40

• For QCS-Only Operator Station install, type the following details.

• QCS Server Name: Enter the Windows computer name of the QCS Server.

• QCS Server Domain: Enter the QCS domain name (normally in the form of RAE_QCS-Server-Name). The QCS Server domain name is the same as the MXDomainName environment variable configured on the QCS Server.

• Click Next.

The Installation Details dialog box appears.

Page 131: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installing RAE R700.1 Installing RAE on an Operator Station

P/N 6510020594 Rev 02 11/22/18 7-41

Verify the details to ensure that it matches your requirements.

• Click Install to proceed with the installation.

• Go to Step 15.

11. Integrated Operator Station for Integrated QCS Server with Non Redundant Experion PKS Server Scenario:

• Select Integrated in the QCS Operator Station Scenarios dialog box.

Page 132: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing RAE R700.1

11/22/18 P/N 6510020594 Rev 02 7-42

• Click Next.

The Experion Version Selection dialog box appears.

Page 133: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installing RAE R700.1 Installing RAE on an Operator Station

P/N 6510020594 Rev 02 11/22/18 7-43

• Select Experion PKS and click Next.

The QCS and Experion PKS Information dialog box appears.

Page 134: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing RAE R700.1

11/22/18 P/N 6510020594 Rev 02 7-44

• Enter the following details.

• QCS Server Name: Enter the Windows computer name of the QCS Server.

• QCS Server Domain: Enter the QCS domain name (normally in the form of RAE_QCS-Server-Name). The QCS Server domain name is the same as the MXDomainName environment variable configured on the QCS Server.

• Experion PKS Server Name: Enter the Windows computer name of the Experion PKS Server.

• Click Next.

The Installation Details dialog box appears.

Page 135: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installing RAE R700.1 Installing RAE on an Operator Station

P/N 6510020594 Rev 02 11/22/18 7-45

Verify the details to ensure that it matches your requirements.

• Click Install to proceed with the installation.

• Go to Step 15.

12. Integrated Operator Station for Integrated QCS Server with Redundant Experion PKS Server Scenario:

• Select Integrated in the QCS Operator Station Scenarios Scenarios dialog box.

Page 136: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing RAE R700.1

11/22/18 P/N 6510020594 Rev 02 7-46

• Click Next.

The Experion Version Selection dialog box appears.

Page 137: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installing RAE R700.1 Installing RAE on an Operator Station

P/N 6510020594 Rev 02 11/22/18 7-47

• Select Experion PKS

• Select Are you connecting to redundant servers (check for yes)? check box

• Click Next.

The QCS and Experion PKS Information dialog box appears.

Page 138: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing RAE R700.1

11/22/18 P/N 6510020594 Rev 02 7-48

• Enter the following:

• QCS Server Name: Type the Windows computer name of the QCS Server.

• QCS Server Domain: Type the QCS domain name (normally in the form of RAE_QCS-Server-Name). The QCS Server domain name is the same as the MXDomainName environment variable configured on the QCS Server.

• Experion PKS Server A Name: Type the Windows computer name of the Redundant Experion PKS Server A.

• Experion PKS Server B Name: Type the Windows computer name of the Redundant Experion PKS Server B.

• Click Next.

The Installation Details dialog box appears.

Page 139: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installing RAE R700.1 Installing RAE on an Operator Station

P/N 6510020594 Rev 02 11/22/18 7-49

Verify the details to ensure that it matches your requirements.

• Click Install to proceed with the installation.

• Go to Step 15.

13. Integrated Operator Station for Integrated QCS Server with Non Redundant Experion PMD Server Scenario:

• Select Integrated in the QCS Operator Station Scenarios dialog box.

Page 140: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing RAE R700.1

11/22/18 P/N 6510020594 Rev 02 7-50

• Click Next.

The Experion Version Selection dialog box appears.

Page 141: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installing RAE R700.1 Installing RAE on an Operator Station

P/N 6510020594 Rev 02 11/22/18 7-51

• Select Experion PMD and click Next.

The QCS and Experion PMD Information dialog box appears.

Page 142: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing RAE R700.1

11/22/18 P/N 6510020594 Rev 02 7-52

• Enter the following details.

• QCS Server Name: Type the Windows computer name of the QCS Server.

• QCS Server Domain: Type the QCS domain name (normally in the form of RAE_QCS-Server-Name). The QCS Server domain name is the same as the MXDomainName environment variable configured on the QCS Server.

• PMD Server Name: Type the Windows computer name of the Experion PMD Server.

• Backup SQL Server Name: This specifies the connection to the backup server for using local language database if the connection to local language database fails in the primary server. Type the Windows computer name of the Experion PMD Server.

• Click Next.

The Installation Details dialog box appears.

Page 143: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installing RAE R700.1 Installing RAE on an Operator Station

P/N 6510020594 Rev 02 11/22/18 7-53

Verify the details to ensure that it matches your requirements.

• Click Install to proceed with the installation.

• Go to Step 15.

14. Integrated Operator Station for Integrated QCS Server with Redundant Experion PMD Server Scenario:

• Select Integrated in the QCS Operator Station Scenarios Scenarios dialog box.

Page 144: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing RAE R700.1

11/22/18 P/N 6510020594 Rev 02 7-54

• Click Next.

The Experion Version Selection dialog box appears.

Page 145: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installing RAE R700.1 Installing RAE on an Operator Station

P/N 6510020594 Rev 02 11/22/18 7-55

• Select Experion PMD

• Select Are you connecting to redundant servers (check for yes)? check box

• Click Next.

The QCS and Experion PMD Information dialog box appears.

Page 146: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing RAE R700.1

11/22/18 P/N 6510020594 Rev 02 7-56

• Enter the following:

• QCS Server Name: Type the Windows computer name of the QCS Server.

• QCS Server Domain: Type the QCS domain name (often in the form of RAE_QCS-Server-Name). The QCS Server domain name is the same as the MXDomainName environment variable configured on the QCS Server.

• Floating IP Address: Floating IP of the Redundant PMD server.

• PMD Server A Name: Type the Windows computer name of the Redundant Experion PMD Server A.

• PMD Server B Name: Type the Windows computer name of the Redundant Experion PMD Server B.

• Backup SQL Server Name: Type the Floating IP of the Redundant PMD Server.

• Click Next.

Page 147: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installing RAE R700.1 Installing RAE on an Operator Station

P/N 6510020594 Rev 02 11/22/18 7-57

The Installation Details dialog box appears.

Verify the details to ensure that it matches your requirements.

• Click Install to proceed with the installation.

• Go to Step 15.

15. Installtion begins and Setup Status dialog box appears indicating the installation progress. This portion of the RAE install should take around three minutes.

Once the installation completed, The InstallShield Wizard Complete dialog box appears.

Page 148: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing RAE R700.1

11/22/18 P/N 6510020594 Rev 02 7-58

16. Select the option Yes, I want to restart my computer now.

17. Do not remove the RAE R700.1 Experion PKS R500.1 Interface Components DVD from the drive.

18. Click Finish.

19. After the computer restarts, logon to Windows as QCSAdmin user.

20. The Experion PKS R500.1 Interface setup automatically completes the installation.

21. After the setup is complete, remove the RAE R700.1 Experion PKS R500.1 Interface Components DVD and proceed to the next section.

Page 149: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installing RAE R700.1 Installing RAE on an Operator Station

P/N 6510020594 Rev 02 11/22/18 7-59

7.2.2. Installing RAE R700.1 Base Media Perform the following steps to install the RAE R700.1 Base Media.

1. Insert the RAE R700.1 Base Components DVD, p/n 6543210127 into the computer’s CD/DVD drive.

The AutoPlay window appears.

2. Double-click Run RAESetup.exe.

3. If the setup window is not launched automatically, perform the following:

• Browse to the root folder of the CD/DVD drive.

• Double-click the RAESetup.exe.

The Welcome to the InstallShield Wizard for RAE 700 Base Components dialog box appears.

4. Click Next.

The Installation Type Selection dialog box appears.

Page 150: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing RAE R700.1

11/22/18 P/N 6510020594 Rev 02 7-60

5. Select the QCS Operator Station option. This is also the correct option for the AllianceView.

6. Click Next.

The Navigation Bar and Station Type Select dialog box appears.

Page 151: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installing RAE R700.1 Installing RAE on an Operator Station

P/N 6510020594 Rev 02 11/22/18 7-61

7. Select the required navigation bar style for this computer.

NOTE: You must select one of the two navigation bar styles before proceeding with the installation.

8. Select one or both check boxes for the station types (Is a Metals Application, Is a MultiMonitor System) where the navigational bar style must be applied.

Example: If you select the Vertical (Best for Wide screen monitors) option and the Is a Metals Application check box, then the vertical navigational style is applied on the user interface of the Metals application.

9. Click Next.

The QCS Operator Station Scenarios dialog box appears.

Page 152: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing RAE R700.1

11/22/18 P/N 6510020594 Rev 02 7-62

10. Select the appropriate QCS Operator Station installation scenario.

11. Click Next.

The QCS Accounts Creation and Password Entry dialog box appears.

Page 153: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installing RAE R700.1 Installing RAE on an Operator Station

P/N 6510020594 Rev 02 11/22/18 7-63

12. Click Next.

The Prompt for Password Change dialog box appears.

13. Type the password for QCSUser username and then click OK.

The Prompt for Password Change dialog box appears.

14. Type the password for Operator username and then click OK.

The License Administrator dialog box appears.

For more information on how to obtain license see section 7.4.

15. Type the License Key details.

16. Click Install Key.

A message box appears confirming the successful installation of the license key.

17. Click OK.

The Installation Details dialog box appears. Verify the installation details to ensure that it is accurate.

Page 154: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing RAE R700.1

11/22/18 P/N 6510020594 Rev 02 7-64

18. Click Install.

The Setup Status dialog box appears displaying the installation progress. This portion of the RAE install should take around seven minutes to complete.

After the installation is complete, the InstallShield Wizard Complete dialog box appears.

Page 155: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installing RAE R700.1 Installing RAE on an Operator Station

P/N 6510020594 Rev 02 11/22/18 7-65

19. Select the option Yes, I want to restart my computer now.

20. Click Finish.

21. After the computer restarts, log into Windows as the QCSAdmin user. Wait for the post-installation setup to complete.

NOTE: Step 22 through Step 24 is applicable only for Alliance View.

22. The Windows PowerShell window appears automatically.

23. Type the QCS Server Name and press [ENTER].

24. To enter details for Is SSL Certificate Installed on QCS Server? refer below table.

Table 7-4 QCS Server Scenarios details for RAE R700 Base Media

QCS Server Scenarios Inputs

QCS Only scenario Enter N

Page 156: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing RAE R700.1

11/22/18 P/N 6510020594 Rev 02 7-66

QCS Server Scenarios Inputs

Integrated QCS Server with Redundant/Non Redundant Experion PKS Server scenario Enter Y

Integrated QCS Server with Redundant/Non Redundant Experion PMD Server scenario Enter Y

NOTE: Step 25 through Step 30 is applicable only for QCS Operator Station and Integrated Operator Station.

25. Click Start > Windows PowerShell.

26. Right-click on Windows PowerShell and select Run as administrator.

27. Type cd "C:\ProgramData\Honeywell\Experion MX\ResourceKit\Setups\Misc\QcsWebDeploymentScripts" and press [ENTER].

28. Type .\Build-EndPointInfo.ps1 and press [ENTER].

29. Enter QCS Server Name and press [ENTER].

30. To enter details for Is SSL Certificate Installed on QCS Server? refer Table 7-4 .

Page 157: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installing RAE R700.1 Installing Patches

P/N 6510020594 Rev 02 11/22/18 7-67

31. The RAE R700.1 Base Componenets setup automatically completes the installation.

7.2.3. Installing Experion MX MD Controls (optional)

For more information on installing the R700.1 Experion MX MD Controls, refer to the document Experion MX MD Controls R700.1 Software Change Notice- p/n 6510020590.

7.2.4. Installing Experion MX CD Controls (optional)

For information about installing Experion MX CD Controls, refer to the document Experion MX CD Controls R700.1 Software Change Notice- p/n 6510020591.

7.3. Installing Patches This section provides information on additional patches installation on QCS nodes. For the most current required patch information, refer the QCS Compatibility Matrix which is available in HoneywellProcess.com website or use the following hyperlink:

http://www.honeywellprocess.com/library/support/Documents/Experion/qcs-compatibility-matrix.zip

Page 158: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing RAE R700.1

11/22/18 P/N 6510020594 Rev 02 7-68

7.4. Obtaining a RAE License Key You need a license key to activate the RAE software. The license key can either be a permanent license key or a temporary license key.

NOTE: To generate the RAE License Key, you will need a computer with intranet/internet access.

7.4.1. To obtain a temporary RAE license 1. In the License dialog box, enter “result” in the license key box.

2. Click Install Key.

The temporary license key has been installed message appears.

3. Click OK.

4. In the license window, click OK and then click Exit.

A temporary license can be used until five days.

NOTE: Do not adjust the computers clock while using a temporary RAE License Key. Adjusting the clock to an earlier time and date can disable the temporary RAE License Key.

7.4.2. To obtain a permanent RAE license 1. Open a Web browser on a computer with Honeywell Intranet

access, and go to the following intranet page:

2. http://bi35ntengweb.dev1.honeywell.com/licadmin/

The Software Licensing window appears.

Page 159: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installing RAE R700.1 Obtaining a RAE License Key

P/N 6510020594 Rev 02 11/22/18 7-69

3. Click the Generate License Key hyperlink.

4. Type the Authorization ID that was provided on the RAE software license card and then click Retrieve.

Page 160: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing RAE R700.1

11/22/18 P/N 6510020594 Rev 02 7-70

5. To obtain the Server code, browse to C:\Program Files (x86)\Honeywell\Experion MX\RAE\bin.

6. Run the Licadmin.exe file to get the server code.

7. Record the Server code.

8. Type the Server code, in the Server code box.

9. Type the System number.

NOTE:

If this package is installed on a customer system, enter the customer name, address, and system number on the registration form.

If there are multiple NIC cards in the license window, select the server code for a network interface card that remains in the computer at all times. Removing the network card disables the RAE license.

10. Type the Company ID and click Retrieve.

11. Click Insert.

The RAE License Key is generated.

12. Record the license key that is generated.

13. Type the RAE License Key in the License Key box.

14. Click Install Key and then click OK.

15. Click Exit.

7.5. Installing RAE R700.1 Solution pack on Non-RAE Experion Nodes

Perform the following steps to install the RAE R700.1 Solution pack on Non-RAE Experion Nodes.

NOTE: RAE R700.1 Solution pack installation is not supported for the feature called Custom Install Paths (CIP) on Experion R500.1 nodes.

Page 161: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installing RAE R700.1 Installing RAE R700.1 Solution pack on Non-RAE Experion Nodes

P/N 6510020594 Rev 02 11/22/18 7-71

1. Logon to the computer as QCSAdmin user in Non-RAE Experion node.

2. Copy QCS_Solution_Pack.iso from QCS Server, C:\ProgramData\Honeywell\Experion MX\Resourcekit\Setups\Misc and paste to Non-RAE Experion node C:\temp.

3. Right-click on QCS_Solution_Pack.iso and select Mount.

4. Double-click the Setup.exe.

The Preparing to Install progress bar appears.

5. The Welcome to the InstallShield Wizard for QCS Solution Pack R700.1 window appears.

6. Click Next.

The License Agreement dialog box appears.

Page 162: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing RAE R700.1

11/22/18 P/N 6510020594 Rev 02 7-72

7. Select I accept ther terms of the license agreement option and then click Next.

The Installation Type Selection dialog box appears.

8. Select the appropriate QCS Solution Pack installation scenario.

9. Proceed with the corresponding installation step by referring the below table.

Table 7-5 QCS Solution Pack installation scenarios details

Page 163: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installing RAE R700.1 Installing RAE R700.1 Solution pack on Non-RAE Experion Nodes

P/N 6510020594 Rev 02 11/22/18 7-73

QCS Solution Pack installation scenarios Steps to follow

QCS Solution Pack for Operator Station scenario Step 10

QCS Solution Pack for Server with Non Redundant Experion PKS Server Scenario Step 11

QCS Solution Pack for Server with Redundant Experion PKS Server Scenario Step 12

10. QCS Solution Pack for Operator Station scenario:

• Select QCS Solution Pack for Operator Station and click Next.

The Installation details dialog box appears.

• Click and Install.

• The InstallShield Wizard complete dialog box appears.

Page 164: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing RAE R700.1

11/22/18 P/N 6510020594 Rev 02 7-74

• Select Yes, I want to restart my computer now and click Finish.

• After the system restarts, logon with the QCSAdmin user.

• Click Start > Windows PowerShell.

• Right-click on Windows PowerShell and select Run as administrator.

• Type cd "C:\ProgramData\Honeywell\Experion MX\ResourceKit\Setups\Misc\QcsWebDeploymentScripts" and press [ENTER].

• Type .\Build-EndPointInfo.ps1 and press [ENTER].

• Enter QCS Server Name and press [ENTER].

• If SSL Certificate installed on QCS Server, press Y. If SSL Certificate is not installed on QCS Server, press N.

Page 165: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installing RAE R700.1 Installing RAE R700.1 Solution pack on Non-RAE Experion Nodes

P/N 6510020594 Rev 02 11/22/18 7-75

• QCS Solution pack for Operator Station installation completed.

11. QCS Solution Pack for Server with Non Redundant Experion PKS Server Scenario:

• Select QCS Solution Pack for Server and click Next.

The Experion Server Flavor dialog box appears.

• Click Next.

The Installation Details dialog box appears.

Page 166: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing RAE R700.1

11/22/18 P/N 6510020594 Rev 02 7-76

• Click Install and go to Step 13.

12. QCS Solution Pack for Server with Redundant Experion PKS Server Scenario:

• Select QCS Solution Pack for Server and click Next.

The Experion Server Flavor dialog box appears.

Page 167: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installing RAE R700.1 Installing RAE R700.1 Solution pack on Non-RAE Experion Nodes

P/N 6510020594 Rev 02 11/22/18 7-77

• Select Yes, Experion Server has redundant server check box and click Next.

The Experion PKS Information dialog box appears.

• Type the Experion Server A Name and Experion Server B Name.

• Click Next.

The Installation Details dialog box appears.

Page 168: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing RAE R700.1

11/22/18 P/N 6510020594 Rev 02 7-78

• Click Install.

• Before clicking Finish in InstallShield Wizard complete dialog box go to Control Panel > System and Security > System > Advanced system settings > Environment variables.

• Select MXExperionServerA under System variables and click Edit.

• Type the Experion Server A Name and click OK.

• Select MXExperionServerB under System variables and click Edit.

• Type the Experion Server B Name and click OK.

• Click OK on Environment Variables dialog box.

• Click OK on System Properties dialog box.

• Go to Step 13.

13. The InstallShield Wizard complete dialog box appears.

Page 169: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Installing RAE R700.1 Installing RAE R700.1 Solution pack on Non-RAE Experion Nodes

P/N 6510020594 Rev 02 11/22/18 7-79

14. Select Yes, I want to restart my computer now and click Finish.

15. After the system restarts, logon with the QCSAdmin user. The Administrator Windows PowerShell window appears.

16. Enter QCS Server Name and press [ENTER].

Page 170: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Installing RAE R700.1

11/22/18 P/N 6510020594 Rev 02 7-80

If SSL Certificate installed on QCS Server, press Y. If SSL Certificate is not installed on QCS Server, press N.

17. QCS Solution pack for Experion Nodes installation completed.

Page 171: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

P/N 6510020594 Rev 02 11/22/18 8-1

8. Post-Installation Steps

8.1. Copy the Product Manual CD files After completion of RAE installation, create folder QCS Manuals in C:\ Program Files(X86)\Honeywell\Experion MX\QCS Manuals and copy the Product Manuals pdf Collection CD (P/N 6537100023) files for future use.

8.2. LabVIEW Mass Compilation

NOTE: On Experion MX Nodes,

Mass compilation of LabVIEW Vis takes 30 to 45 minutes.

You must mass compile the LabVIEW on all the RAE nodes including QCS Server, Operator Station and Alliance view Server. Perform the following steps to carry out Mass Compilation:

1. Click Start > Experion MX Engineering Tools > MassCompile.

User Account Control dialog box appears.

2. Click Yes.

MassCompile command prompt appears.

Page 172: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Post-Installation Steps

11/22/18 P/N 6510020594 Rev 02 8-2

3. The Mass Compilation automatically completes the compilation.

NOTE: The log file RAE_MassCompileLog.txt will be created by Labview during mass compilation if it does not exist on the system already.

NOTE: After mass compile of the Experion MX folder you should receive errors related to SourceSafe, field point, File Op.

NOTE: After mass compile of the Experion MX folder, if you observe errors related to Insane object identified is in SP Z2 Axis Calc.vi, then it is recommended to mass compile once again.

Page 173: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Post-Installation Steps Internet Explorer

P/N 6510020594 Rev 02 11/22/18 8-3

NOTE:

Normally, during Mass compilation of LabVIEW files error log messages are generated for Not found VIs, Bad Vis, and CompileFolder. These error messages can be identified as follows:

• Not found VIs identified are FP Open.vi, FP Create Tag.vi, FP Read (Polymorphic).vi, FP Read (Boolean).vi, FP Close.vi and FP Read.vi.

• Bad VIs identified are pulse tachs inputs.vi and FieldPoint io status monitor.vi.

• Insane object identified is in SP Z2 Axis Calc.vi

If other VIs are identified in the log, this may indicate another problem.

8.3. Internet Explorer While you navigate through displays, display navigation may fail with an Internet Explorer exception error. To overcome this problem, you must add the following three websites to the trusted sites.

• file://servermachinename

• http://servermachinename

• about:security_HSCStationwindow.exe

Perform the following steps to add the websites to the trusted sites.

1. Launch Internet Explorer.

2. Click Settings > Internet Options.

3. Click the Security tab.

4. Select Trusted Sites and click on Sites.

The Trusted Sites dialog box appears.

5. Clear Require server verification (https:) for all sites in this zone check box.

6. Type the website name in Add this website to the zone box.

Page 174: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Post-Installation Steps

11/22/18 P/N 6510020594 Rev 02 8-4

NOTE: While you navigate through the other displays, if the display navigation fails with an Internet Explorer exception error add those websites to the trusted sites in the similar way as explained in this section to overcome the problem.

7. Click Add.

8. Click Close.

NOTE: If you are performing the steps that are mentioned in section 8.3 on an AllianceView or, on a QCS server that is enabled with Remote Desktop Services, you must ensure to login with each user account used for connecting the Remote Desktop clients and add the trusted sites.

Page 175: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Post-Installation Steps Modifying the Configuration Settings of the Monitor Display

P/N 6510020594 Rev 02 11/22/18 8-5

8.4. Modifying the Configuration Settings of the Monitor Display

You can experience the LabVIEW drawmngr.cpp error (LabVIEW crash) that is caused by certain configuration settings done on the monitor display. The configuration settings that can potentially cause this issue on the monitor display include:

• Non-recommended color quality settings

• Hardware acceleration turned ON

• Insufficient GDI Objects Quota

The LabVIEW error can also be caused due to the installation of non-compatible display adapters (not provided by monitor manufacturer) installed by third party applications that are not recommended by the Honeywell.

In order to avoid the LabVIEW drawmngr.cpp error (LabVIEW crash) caused due non recommended monitor display configuration, you need to perform the following steps, in the order mentioned:

1. Modifying the configuration settings of the Monitor Display.

2. Uninstalling the additional display drivers installed by Third party applications.

8.4.1. Modifying the Configuration Settings of the Monitor Display

8.4.1.1. Setting the Monitor Color Quality

1. Right-click on the desktop and select Display settings.

The Settings dialog box appears.

2. Select Display.

The Display dialog box appears.

3. Click Advanced display settings.

The Advanced display settings dialog box appears.

Page 176: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Post-Installation Steps

11/22/18 P/N 6510020594 Rev 02 8-6

4. Make sure the Resolution is 1280 x 1024.

5. Click Apply.

6. A message appears to asking you to keep the changed display settings, click Keep changes.

7. Close the Settings dialog box.

8.4.1.2. Increasing the GDI Objects Quota

1. Choose Start > Run.

2. Type Regedit in the Run command box.

The Registry Editor dialog box appears.

3. Browse to the following location: HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows NT\CurrentVersion\Windows

4. Double click on GDIProcessHandleQuota from the right pane.

The Edit DWORD (32-bit) Value dialog box appears.

Page 177: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Post-Installation Steps Modifying the Configuration Settings of the Monitor Display

P/N 6510020594 Rev 02 11/22/18 8-7

5. Select Decimal option under Base and set the Data for GDIProcessHandleQuota to 65536.

6. Click OK.

7. Close the Registry Editor dialog box.

Page 178: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Post-Installation Steps

11/22/18 P/N 6510020594 Rev 02 8-8

8.4.2. Uninstalling the Additional Display Drivers Installed by Third Party Applications

LabVIEW drawmngr.cpp error(LabVIEW crash) can be caused due to non-compatible display adapters (not provided by monitor manufacturer) installed by third party applications. An example of the non-compatible display adapter installed is Radmin.

To avoid LabVIEW drawmngr.cpp error(LabVIEW crash) caused due to non-compatible display adapters installed by third party applications, perform the following steps.

NOTE Perform the steps described in this section only if you have installed the additional display drivers apart from the default monitor driver.

Refer to the Experion PKS System Initialization Media Software Change Notice release document for the list of recommended drivers.

Windows Server 2016 users

1. Open the Device Manager by, Go to Start and then Right-click Computer, and then click Manage.

2. If the User Account Control dialog box appears, click Continue.

3. The Server Manager window appears.

4. Click Diagnostics in the left pane.

5. Select Device Manager.

6. Expand the Display adapters in the right pane.

7. All the installed Display Drivers will be displayed.

8. Verify if the display adapters other than the ones provided by the monitor manufacturer are installed.

9. If yes, right-click the display adapter and click Uninstall.

10. If no, ignore the steps 5 and 6.

11. Restart the computer.

Page 179: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Post-Installation Steps Scanner Software

P/N 6510020594 Rev 02 11/22/18 8-9

Windows 10 64 Bit users

1. Open the Device Manager by, Go to Start and right-click Computer, and then click Manage.

2. If the User Account Control dialog box appears, click Continue.

3. The Computer Management window appears.

4. Click System Tools in the left pane.

5. Select Device Manager.

6. Expand the Display adapters in the right pane.

7. All the installed Display Drivers will be displayed.

8. Verify if the display adapters other than the ones provided by the monitor manufacturer are installed.

9. If yes, right-click the display adapter and click Uninstall.

10. If no, ignore the steps 5 and 6.

11. Restart the computer.

8.5. Scanner Software It is recommended that the RAE R700 release use a minimum of one the following Experion MX Scanner Software releases.

Experion MX Scanner Software R107.7 SCN 6510020592

Experion MX Scanner Software R202.0 SCN 6510020605

Refer the SCNs for further informations.

Please refer QCS Compatibity Matrix (MSS and EDAQ tab) for the latest MSS and EDAQ Software release information.

The MSS and EDAQ Software vesion mentioned in above table is the latest supported version at the time of Experion MX R700.1 release.

Page 180: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection
Page 181: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

P/N 6510020594 Rev 02 11/22/18 9-1

9. Third Party Software

9.1. Installing Other Third Party Software This section provides information on additional third party software you may wish to install on the QCS nodes. You should only install software which has been qualified for use on your version of RAE. For the most current software compatibility information, consult the QCS Compatibility Matrix which is available in HoneywellProcess.com website or use the following hyperlink:

http://www.honeywellprocess.com/library/support/Documents/Experion/qcs-compatibility-matrix.zip

9.1.1. Microsoft Security Updates

NOTE: Updates for R700 release in below link will be available by end of April 2017.

You can use the SUIT ISO image to install the latest qualified Microsoft Security updates on all QCS nodes. For more information on the installation of Microsoft Security Updates refer to:

www.honeywellprocess.com/library/support/security-updates/Experion/suit-iso-user-guide.pdf

You can download the latest SUIT ISO from the HoneywellProcess.com support site. Log in with the credentials. Click on the SUPPORT tab and then search for something like “Feb 2017 ISO” (or use the most recent month and year). Open the Datasheet and click on the Download ISO Image.

You can download the latest microsoft-security-hot-fixes-honeywell-qualification-matrix from the HoneywellProcess.com support site. Log in with the credentials. Click on the SUPPORT tab and then search for “Honeywell

Page 182: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Third Party Software

11/22/18 P/N 6510020594 Rev 02 9-2

Qualifiation Matrix”. Click on the PRODUCT DOCUMENTS & DOWNLOADS tab.

NOTE: Updated HQM-MS Security Updates II sheet for R700 release will be available by end of April 2017.

Copy the Honeywell Qualification Matrix and view the HPS recommendations for all recent Microsoft Security Updates (the QCS nodes are on the HQM-MS Security Updates II sheet).

9.1.2. Installing Symantec Endpoint Protection

NOTE: Updates for R700 release in below link will be available by end of April 2017.

Symantec Endpoint Protection is supported for the RAE R70x release. For more information on the qualified version and configuration of the Symantec Endpoint Protection refer to

www.honeywellprocess.com/library/support/Documents/Trusted/Experion/anti-virus-software-guidelines.pdf

NOTE: While installing the Anti-Virus software, ensure that the software is setup not to scan the Honeywell folders.

Page 183: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Third Party Software Installing Other Third Party Software

P/N 6510020594 Rev 02 11/22/18 9-3

9.1.3. Installing McAfee Antivirus Software

NOTE: Updates for R700 release in below link will be available by end of April 2017.

McAfee Antivirus is supported for the RAE R70x release. For more information on the qualified version and configuration of the McAfee Antivirus refer

www.honeywellprocess.com/library/support/Documents/Trusted/Experion/anti-virus-software-guidelines.pdf

9.1.4. Installing Adobe Reader You must install Adobe Reader on the Experion MX node to view the PDF files.

NOTE: Updates for R700 release in procedure will be available by end of April 2017.

To check the Adobe Reader Qualified Version

1. Log into www.HoneywellProcess.com.

2. Click Support tab and then type Adobe Reader Update Guidelines in the search bar and click Search, then in Sort by tab select Release Date (newest)

3. This will display the latest Qualified Adobe Reader Packages document.

4. Check the Qualified Adobe Reader version for your node.

To install the Qualified Adobe Reader

5. Insert the latest Experion MX R500.1 PDF Collection DVD (p/n 51155348) Release 500.1 into the CD/DVD-ROM drive.

Or

Browse to D_PDF folder under ESIS folder

6. Browse to the Adobe Reader folder select the appropriate Adobe Reader and install.

Page 184: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Third Party Software

11/22/18 P/N 6510020594 Rev 02 9-4

9.1.5. HP Switch Firmware Updates

NOTES: The user should be logged into the www.honeywellprocess.com site to use the below links.

Perform the following steps to view the qualified HP Switch Firmware updates.

1. Go to www.HoneywellProcess.com.

2. If you have already registered in this site, Under Account Login enter the User Id and Password to login to this site.

3. Choose Support > Product Support > See more.

4. Under the field Latest Support Files, click Latest Notifications.

5. Next Click on Notification under Notification Category present on the Left pane

6. Now type HP in the search bar and click search, then in Sort by tab select “Release Date (newest)” as highlighted in the screen shot. This will give the latest qualified HP switch firmware data sheet.

Page 185: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Third Party Software Installing Other Third Party Software

P/N 6510020594 Rev 02 11/22/18 9-5

Page 186: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection
Page 187: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

P/N 6510020594 Rev 02 11/22/18 10-1

10. Advisories

10.1. Stopping the Experion Performance Monitoring

In RAE R700.1 with Experion PKS R500.1, after the Experion installation is complete, the Experion Performance Monitor setup is automatically enabled, and starts monitoring the process in the system. This automatic monitoring of process generates unnecessary log files and affects the performance of the system.

For improving the System performance, the Experion Performance must be stopped.

To stop the Experion Performance Monitor in Windows Server 2016 environment:

1. Right-click Start and select Computer Management.

The Computer Management window appears.

2. From the Server Manager, select and expand Performance > Data Collector Sets > User Defined > Experion_Performance_Logs.

Page 188: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Advisories

11/22/18 P/N 6510020594 Rev 02 10-2

3. The Experion Performance Logs details are displayed in the right pane.

4. Right-click Experion_Performance_Logs and then click Stop.

5. The Experion Performance Monitor setup is stopped.

To stop the Experion Performance Monitor in Windows 10 64 Bit environment:

1. Choose Start > Windows System > Control Panel

2. The All Control Panel Items dialog box will apperas.

3. Click Administrative Tools.

4. The Administrative Tools dialog box appears.

5. Double click Computer Management.

6. The Computer Management dialog box appears.

7. From the Computer Management, select and expand System Tools>Performance>Data Collector Sets>User Defined> Experion_Performance_Logs.

8. The Experion Performance Logs details are displayed in the right pane.

Page 189: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Advisories Links and I/O Point Names

P/N 6510020594 Rev 02 11/22/18 10-3

9. Right-click Experion_Performance_Logs and then click Stop from the short cut menu.

10. The Experion Performance Monitor setup is stopped.

10.2. Links and I/O Point Names Do not add different links to the system with the same I/O point name because it produces errors in the Database Browser (PAR# Activ00004827).

Do not add similar links to the system with the same I/O point name because it produces errors in the Database Browser (PAR# Activ00004822).

10.3. RAE Control Panel - Station startup and options

Start the Station program on the Operator Station with the –slcp option. This option runs Station in full screen mode, with no access to the Connection properties.

Page 190: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Advisories

11/22/18 P/N 6510020594 Rev 02 10-4

1. Choose Start > Experion MX Startup Tools > RAE Control Panel to start the RAE Control Panel.

2. Click the explore button ( ) to view the configuration settings for this application.

3. In the Connection File and Flags field, enter RAE.stn –slcp.

4. Close the RAE Control Panel.

10.4. Touch Screen with QCS Nodes This section will give brief idea on how to set up the Touch screen monitors for usage with QCS nodes.

NOTES: Please refer QCS Compatibity Matrix for the latest Drivers release information.

NOTES: In this section Elo Touch Screen (Model no:ET1929LM ) with USB cable has been taken as an example.

1. You need to connect video cable of the Touch Screen as well as touch screen related USB cable to the workstation. If needed refer the product guide of the Touch screen for connection details.

2. Go to https://support.elotouch.com/Download/Drivers/DriverDownload/ and download.

3. Double-click the EloSetup.exe file.

Elo Touchscreen Setup dialog box appears.

4. From the drop-down list, select the appropriate language to continue with the setup.

5. Click Next.

The Welcome to Elo Touchscreen Setup dialog box appears.

6. Select, Install USB Touchscreen Drivers

7. Click Next.

Page 191: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Advisories Touch Screen with QCS Nodes

P/N 6510020594 Rev 02 11/22/18 10-5

The License Agreement dialog box appears.

8. Read the license agreement details and then click Yes.

The Installing Elo Touchscreen drivers and components dialog box appears, indicating the progress of installation.

9. The Setup Complete dialog box appears.

10. In the Setup Complete dialog box check the check box Calibrate Elo Touchscreen monitors.

11. Click Finish.

12. A calibration window appears indicating the start of calibration. You need to complete the calibration process to use the touch screen monitor. Also note during the calibration process, the wizard prompts you to touch three circles which gets displayed one after the other on three different locations of the screen. This enables necessary calibration adjustment with the Touch Screen.

13. Follow the on screen instructions to complete the calibration of the touch screen monitor.

14. Touch the Green Tick mark to complete the calibration.

Page 192: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

RAE R700.1 Release and Installation Notes Advisories

11/22/18 P/N 6510020594 Rev 02 10-6

15. Click Exit in the Elo TouchSystems TouchTools dilog box and remove the Production DVD.

16. In future during the usage of Touch screen, if you find calibration is again needed. You can carry out the same by following below procedure:

17. Click Elo icon in the tool tray which is available at the lower right side of the desktop

18. Click Align

19. A calibration window appears indicating the start of calibration. You need to complete the calibration process to use the touch screen monitor. Also note during the calibration process, the wizard prompts you to touch three circles which gets displayed one after the other on three different locations of the screen. This enables necessary calibration adjustment with the Touch Screen

20. Follow the on screen instructions to complete the calibration of the touch screen monitor.

21. Touch the Green Tick mark to complete the calibration.

Page 193: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

Advisories Wide Screen Monitor with QCS Node

P/N 6510020594 Rev 02 11/22/18 10-7

NOTES: If Elo icon is not available in the tool tray on Windows 7 Professional 64 Bit operator system, go to Control Panel, look for “View by: Category” text toward the upper right; click it and select "Small icons" , double-click Elo Touchscreen icon and click the Align button on the General tab.

10.5. Wide Screen Monitor with QCS Node The QCS Nodes support both Wide Screen and Standard monitors. The following screen resolutions are supported for wide screen monitors:

1680 X 1050

1920 X 1200

NOTES: All the Monitors in Multi-Monitor setup need to use same screen resolution.

1. Right-click anywhere on the Winodws Desktop, select Screen resolution from Context menu

2. Then a Screen Resolution Window appears.

3. If this is a Multi Monitor setup, select the required monitor from the Display combo box. In this is a Single Monitor setup, the Display combox box will be disabled.

4. Then select one of the screen resolutions listed below:

5. 1680 X 1050 1920 X 1200

6. Then click Apply.

7. For Multi Monitor setups, repeat 3 to 5 for each Monitor

8. Then close the Screen Resolution window.

Page 194: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection
Page 195: balibago.orgbalibago.org/Files/R700/R701 Update File/R701.2... · This manual is a product of Honeywell. It is intended for use only by Honeywell and customer personnel in connection

P/N 6510020594 Rev 02 11/22/18 11-1

11. Glossary

Experion MX Name for a Honeywell QCS system. DCS Distributed Control System HMI Human Machine Interface MD CD

Machine Direction The direction paper travels down the paper machine. Cross Direction: It is transverse to the MD (Machine Direction) that relates to a position along the length of the paper machine

MIS Management Information Summaries A software package that accumulates and presents production data (reports) mill management.

MXProLine Name for a Honeywell QCS system. QCS Quality Control System

A computer system that manages the quality of the paper produced. RDM PMD CIP

Redirection Manager Process Machine Drives Custom Install Paths