ADDENDUM No. 1
Date: January 26, 2017 From: Leslie Burke, Purchasing Agent Re: T16-1613 Residence 2 Interior Renovation Please find attached Addendum No. 1
Purchasing Agent Contracts and Supply Chain Management University of Northern British Columbia
ADDENDUM No. 1
CONTRACTOR IDL Projects
Craig Cocker 1088 Great Street, Prince George, BC
OWNER UNBC
ARCHITECT HCMA Architecture + Design
PROJECT Keyoh Residence Renovation
DATE January 25, 2017
The following revisions supersede the information contained in original Tender Documents issued for the above named project, to the extent referenced and shall become a part thereof. This Addendum forms part of the contract documents and is to be read, interpreted, and coordinated with all other parts. The cost of information contained herein is to be included in the contract sum. No consideration will be allowed for extra due to the Contractor, or to any Subcontractor or Supplier, not being familiar with this addendum. Acknowledge receipt of this Addendum by inserting its number and date on the Tender Form. Failure to do so may subject bidder to disqualification. TITLE
Item Reference Description
ARCHITECTURAL ITEMS
1.1 A3.00, A3.10, A6.00
DELETE: PVC Windows will not be a part of this contract.
1.2 1.3
Spec 085310 Spec 088050 Spec 092116 Spec 092116
Section 085310‐ Delete section in entirety. Section 08 80 50 REMOVE Paragraph 1.1.2 in entirety. REMOVE Article 2.3 in entirety. REVISE: Gypsum Board Assemblies- Ceiling boarding to be 5/8” type x with furring layer of ¼” type c GWB. Section 09 21 16 ADD Subparagraph 2.1.1.1 to read as follows: 2.1.1.1 Combine/layer Type X gypsum board combined with 1/4 inch Type C gypsum board for 1 hour ratings for ceilings. Attach and seal as required to meet required ratings. REVISE: Gypsum Board Assemblies- Ceiling to be skim-coated in their entirety and sanded smooth to provide a smooth, level surface to receive paint.. REVISE Paragraph 3.8.1 in entirety to read as follows:
1.4 1.5
A9.00, A9.10, Schedule 1
Finish in accordance with ASTM C840 or AWCC for appropriate level finish for light levels, paint gloss, and visibility.
REMOVE Paragraph 3.9.4 in entirety. ADD: UNBC Childcare Renovations to Scope of work. Scope as laid out in accordance with drawings and summarized below. Specifications issued for Keyoh shall govern this added scope. -Replace select areas of flooring -Provide separate price for select areas of replaced flooring-as identified in drawings. -Patch, repair and repaint most interior drywall surfaces with new colour scheme. -Add protective padding to select locations. -Exterior painting and repairs –as identified on drawings. -Replace lighting fixtures with new fixtures in same location. -Connect building to UNBC District Energy System and cover scope of work identified in Mech. documents. Mech documents to be issued under separate later Addendum
ADD DOCUMENT : IDL Schedule 1 Proponent Submission Checklist Tender T16-1613
PREPARED BY THE CONSULTANT
HCMA Architecture + Design Ian McLean, Architect AIBC January 25, 2017
CONSULTANT………………………….. TITLE…………………………..…………….……. DATE………………………………………
1
1:100
WEST ELEVATION - NORTH WING
2
1:100
WEST CORE ELEVATION - CONNECTOR BETWEEN NORTH-SOUTH WING
3
1:100
WEST ELEVATION - SOUTH WING
SCOPE OF WORK
(MINOR ENVELOPE REMEDIATION)
SOFFIT REPAIR:
REPLACE BUCKLED
AND DAMAGED
SOFFIT PANELS.
CAULK AROUND
EXISTING AIR
SENSER EQUIPMENT
ELEVATOR SHAFT
SCUPPER REPAIR:
REPAIR WATER
DAMAGED SHINGLES
AND INSTALL SPLASH
PAD UNDER
SCUPPER.
Copyright reserved. These drawings and the design contained therein or which may be inferred therefrom are, and at all times remain, the exclusive property of HCMA Architecture + Design (HCMA). HCMA holds the copyright and ownership in the said drawings, which cannot be used for any purpose without the express written consent of HCMA. CHECKED: DRAWN:PROJECT # 1669 IM DP
ISSU
ED
FO
R CO
ORD
IN
ATIO
NN
OVEM
BER.3.3016
ISSU
ED
FO
R 90%
CO
ORD
IN
ATIO
ND
ECEM
BER.22.2016
ISSU
ED
FO
R TEN
DER
JAN
UARY.13.2017
AD
DEN
DU
M 1
JAN
UARY.25.2017
--
--
--
--
--
--
REN
OVATIO
N
KE
YO
H_R
ES
ID
EN
CE
UN
BC
-S
TU
DE
NT
-H
OU
SIN
G
A3.00
1:1
00
JA
NU
AR
Y.1
7.2
01
7
BU
IL
DIN
G_E
LE
VA
TIO
N
DA
TE
:
SC
AL
E:
HCMA Architecture + Design
400 - 675 West Hastings Street
Vancouver BC V6B 1N2 Canada
T 604.732.6620
W hcma.ca
SUMMARY OF WORK
1. Dryer vents require full clean out and several require flashing. Exhaust fan vents require
assessment for possible envelope remediation. Refer to Mechanical drawings for locations
of vent outlets in wall. Patch and make good any water damaged areas of stucco cladding.
(to be assessed on-site by CM)
2. Repairs as noted to cladding and building envelope as noted and - to be assessed by CM
onsite.
3. Limited repairs to existing interlocking asphalt shingle (to be assessed on-site by CM)
1
1:100
NORTH SIDE ELEVATION
2
1:100
EAST ELEVATION - NORTH WING
3
1:100
ADMIN-CORNER ELEVATION
8
1:100
EAST ELEVATION - SOUTH WING
9
1:100
SOUTH ELEVATION
LAUNDRY ROOM
STUDY
STUDY
LAUNDRY ROOM
4
1:100
EAST CORE ELEVATION
EXISTING ELEVATIONS FOR REFERENCE ONLY- (NO CHANGES)
WINDOW TRIM REPAIR
: REPLACE OR
REPAIR DAMAGED
BOTTOM WINDOW
TRIM.
SOFFIT VENT REPAIR:
CLEAN OUT SOFFIT
VENTS AND INSTALL
TRIM/ FLASHING
AROUND DRYER
VENTS.
CEDAR SIDING REPAIRS : REVIEW
PERIMETER OF BUILDING AND
REPLACE/ RE-ATTACH ANY BOARDS
WHICH HAVE BUCKLED OR POPPED.
CANOPY REPAIR-
SOFFIT : REPLACE
OR REPAIR DAMAGED
PREFINISHED
ALUMINUM SOFFIT
PANELS. ALSO
REPLACE + PAINT
DAMAGED BOTTOM
SIDING PLANKS AT
PERIMETER OF
CANOPY.
CEDAR SIDING
REPAIR:
REPAIR/REPLACE
BUCKLING SIDING
BOARDS + REPAINT
AFFECTED AREA.
Copyright reserved. These drawings and the design contained therein or which may be inferred therefrom are, and at all times remain, the exclusive property of HCMA Architecture + Design (HCMA). HCMA holds the copyright and ownership in the said drawings, which cannot be used for any purpose without the express written consent of HCMA. CHECKED: DRAWN:PROJECT # 1669 IM DP
ISSU
ED
FO
R CO
ORD
IN
ATIO
NN
OVEM
BER.3.2016
ISSU
ED
FO
R 90%
CO
ORD
IN
ATIO
ND
ECEM
BER.22.2016
ISSU
ED
FO
R TEN
DER
JAN
UARY.13.2017
AD
DEN
DU
M 1
JAN
UARY.25.2017
--
--
--
--
-
10
REN
OVATIO
N
KE
YO
H_R
ES
ID
EN
CE
UN
BC
-S
TU
DE
NT
-H
OU
SIN
G
A3.10
1:1
00
JA
NU
AR
Y.2
5.2
01
7
BU
IL
DIN
G_E
LE
VA
TIO
N
DA
TE
:
SC
AL
E:
HCMA Architecture + Design
400 - 675 West Hastings Street
Vancouver BC V6B 1N2 Canada
T 604.732.6620
W hcma.ca
SUMMARY OF WORK
1. Dryer vents require full clean out and several require flashing. Exhaust fan vents require
assessment for possible envelope remediation. Refer to Mechanical drawings for locations
of vent outlets in wall. Patch and make good any water damaged areas of stucco cladding.
(to be assessed on-site by CM)
2. Repairs as noted to cladding and building envelope as noted and - to be assessed by CM
onsite.
3. Limited repairs to existing interlocking asphalt shingle (to be assessed on-site by CM)
1. DO NOT SCALE DRAWINGS. LARGER SCALE DRAWINGS TAKE
PRECEDENCE OVER SMALLER SCALE DRAWINGS.
2. ALL SUB-CONTRACTORS SHALL EXERCISE PROPER PRECAUTION
TO VERIFY DIMENSIONS SHOWN ON THE DRAWINGS BEFORE LAYING
OUT THEIR WORK AND BE RESPONSIBLE FOR ANY ERROR RESULTING
FROM THEIR FAILURE TO EXERCISE SUCH PRECAUTION. ALL CHANGES
TO THE WORK NOT IN CONFORMANCE WITH THE DRAWINGS TO BE
APPROVED BY THE CONSULTANTS PRIOR TO THE EXECUTION OF THE
WORK.
3. INTERIOR DIMENSIONS ARE TAKEN TO CENTRE LINE OF WALLS
UNLESS NOTED OTHERWISE.
4. ALL DEVIATIONS FROM THESE DRAWINGS TO BE APPROVED BY
THE ARCHITECT. THE GENERAL CONTRACTOR IS TO MAINTAIN AN
ADDITIONAL SET OF DRAWINGS FOR NOTATION ON SITE INDICATING ALL
CHANGES FROM THE APPROVED B.P. SET FOR USE BY CONSULTANTS IN
PREPARATION OF 'RECORD DRAWINGS' AS REQUIRED. THE GENERAL
CONTRACTOR IS TO KEEP A WRITTEN RECORD OF ALL CHANGES.
NOTIFY THE ARCHITECT IMMEDIATELY OF ANY PROPOSED CHANGES IN
THE WORK, AND DO NOT PROCEED WITH CHANGES UNTIL APPROVED.
ON COMPLETION OF WORK, RETURN APPROVED BUILDING PERMIT
DRAWINGS TOGETHER WITH MARK-UP SITE SET TO ARCHITECT,
CLEARLY NOTING ANY ADDITIONAL INFORMATION TO FULLY DESCRIBE
BUILDING AS-BUILT.
5. SHOP DRAWINGS FOR ALL SEISMIC RESTRAINT OF BUILDING
COMPONENTS AND FIRE RATED SEALANTS TO BE PREPARED BY AN
ENGINEER REGISTERED IN THE PROVINCE OF B.C. AND SUBMITTED TO
THE ARCHITECT PRIOR TO MANUFACTURER. FOLLOW UP ON FIELD
REVIEW BY THE SIGNING ENGINEER IS MANDATORY WITH LETTERS
AND/OR FIELD REPORTS TO CONFIRM.
6. MAKE GOOD ALL EXISTING CONSTRUCTION AND FINISHES AFFECTED
BY NEW WORK.
7. ALL WORK TO COMPLY WITH 2012 EDITION OF THE BRITISH COLUMBIA
BUILDING CODE.
8. SEE FIRESTOPPING SPECIFICATION FOR FIRESTOPPING
REQUIREMENTS.
GENERAL NOTES
HCMA Architecture + Design
400 - 675 West Hastings Street
Vancouver BC V6B 1N2 Canada
T 604.732.6620
W hcma.ca
Copyright reserved. These drawings and the design contained therein or which may be inferred therefrom are, and at all times remain, the exclusive property of HCMA Architecture + Design (HCMA). HCMA holds the copyright and ownership in the said drawings, which cannot be used for any purpose without the express written consent of HCMA.
CHECKED: DRAWN:PROJECT # 1669 IM DP
ISSU
ED
FO
R CO
ORD
IN
ATIO
NN
OVEM
BER 3, 2016
ISSU
ED
FO
R 90%
CO
ORD
IN
ATIO
ND
ECEM
BER.22.2016
ISSU
ED
FO
R TEN
DER
JAN
UARY.13.2017
AD
DEN
DU
M 1
JAN
UARY.25.2017
--
--
--
--
--
--
-REN
OVATIO
NS
KE
YO
H-R
ES
ID
EN
CE
UN
BC
-S
TU
DE
NT
-H
OU
SIN
G
A0.00
N/A
JA
NU
AR
Y.2
5,2
01
7
SIT
E-P
LA
N/N
OT
ES
DA
TE
:
SC
AL
E:
UNBC KEYOH RESIDENCE RENOVATION
ISSUED FOR ADDENDUM 1 - JANUARY 25, 2017
Architectural
HCMA Architecture + Design
400-675 West Hastings Street
Vancouver, BC V6B 1N2
T 604.732.6620
Structural Consultant
Simon & Co
7685 Tingsley Crescent
Prince George, BC V6J 2G8
T 250.563.8383
Mechanical Consultant
CWT Cor-Wil Technologies Ltd.
203-1449 St Paul Street
Kelowna, BC V1Y 2E4
T 778.478.9857
Electrical Consultant
NRS Engineering Ltd
212-556 North Nechako Road
Prince George, BC V2K 1A1
T 250.562.0551
F 250.562.0558
CONSULTANTS
PROJECT DATA
Project Address:
KEYOH RESIDENCE, 2323 RESIDENCE COURT
UNBC, PRINCE GEORGE BC, V2N 5H2
CLIENT
UNIVERSITY OF NORTHERN BRITISH COLUMBIA
3333 UNIVERSITY WAY,
PRINCE GEORGE BC. V2N 4Z9
Legal Description:
Lot A District Lot 2611, 2612, 2615 and 2616 Cariboo District Plan
PG 39723 PID 023-384-697
Project Description:
Renovations to Keyoh Student Residences. Primary scope of work
is interior refurbishment of suites, including replacement of interior finishes,
plumbing and lighting fixtures. The scope also involves minor
repairs to existing envelope and refresh interior finishes in Common Areas.
Building Area:
South Building -3 storey's: 3054 sq.m
North Building -4 storey's: 4416 sq.m
Occupancy: Group C
Construction: Combustible
Sprinklered: Yes
Standpipe: Class 1
Fire Alarm System: Yes
DRAWING LIST
ELECTRICAL
MECHANICAL
E0 LEGENDS AND SCHEDULES AS NOTED
E1 LEVEL 1 NORTH- POWER LAYOUT 1:100
E2 LEVEL 2 POWER LAYOUT 1:100
E3 LEVEL 3 POWER LAYOUT 1:100
E4 LEVEL 4 POWER LAYOUT 1:100
E5 SUITE LAYOUTS AS NOTED
E6 SUITE LAYOUTS AS NOTED
M1.0 SITE PLAN, SCHEDULES & DRAWING LIST AS NOTED
M2.0 DEMO PLAN - TYPICAL SUITES AS NOTED
M2.1 DEMO PLAN - TYPICAL SUITES AS NOTED
M3.0 RENO PLAN - TYPICAL SUITES AS NOTED
M3.1 RENO PLAN - TYPICAL SUITES AS NOTED
M3.2 MECH AND LAUNDRY ROOM PLANS AS NOTED
M4.1 LEVEL 1 PLAN- HYDRONIC 1:100
M4.2 LEVEL 2 PLAN- HYDRONIC 1:100
M4.3 LEVEL 3 PLAN- HYDRONIC 1:100
M4.4 LEVEL 4 PLAN- HYDRONIC 1:100
M5.1 LEVEL 1 PLAN- FIRE PROTECTION 1:100
M5.2 LEVEL 2 PLAN- FIRE PROTECTION 1:100
M5.3 LEVEL 3 PLAN- FIRE PROTECTION 1:100
M5.4 LEVEL 4 PLAN- FIRE PROTECTION 1:100
M6.1 MECHANICAL SCHEMATIC AS NOTED
M7.1 MECHANICAL DETAILS AS NOTED
M7.2 MECHANICAL DETAILS AS NOTED
M8.2 SCHEDULES AS NOTED
ARCHITECTURAL
A0.00 SITE PLAN / NOTES AS NOTED
A0.01 FINISH SCHEDULES / ASSEMBLIES AS NOTED
A0.02 FINISH SCHEDULES AS NOTED
A0.03 SUITE AUDIT AS NOTED
A0.04 SUITE AUDIT AS NOTED
A0.05 DOOR + HARDWARE SCHEDULE AS NOTED
A0.06 DOOR + HARDWARE SCHEDULE AS NOTED
A2.01 LEVEL 1 FLOOR PLAN 1:100
A2.02 LEVEL 2 FLOOR PLAN 1:100
A2.03 LEVEL 3 FLOOR PLAN 1:100
A2.04 LEVEL 4 FLOOR PLAN 1:100
A2.11 LEVEL 1 RCP 1:100
A2.12 LEVEL 2 RCP 1:100
A2.13 LEVEL 3 RCP 1:100
A2.14 LEVEL 4 RCP 1:100
A3.00 BUILDING ELEVATION 1:100
A3.10 BUILDING ELEVATION 1:100
A4.00 SECTIONS 1:100
A5.10 ADMIN ENLARGED PLAN 1:50
A5.40 TYPICAL SUITE PLANS 1:50
A5.41 TYPICAL SUITE PLANS 1:50
A5.42 SUITE INT. ELEVATIONS 1:50
A5.50 LAUNDRY ROOM/ STUDY PLAN/ INT. ELEVS 1:20
A7.00 DETAILS / MILLWORK AS NOTED
A7.10 COLOUR INTERIOR ELEVATIONS AS NOTED
A9.00 UNBC CHILDCARE RENO- NOTES-SCHEDULES AS NOTED
A9.01 UNBC CHILDCARE RENO-FLOOR PLAN AS NOTED
SITE PLAN - LEGEND
AREA OF BUILDING TO BE RENOVATED
Building Envelope Consultant
Spratt Emanuel Engineering Ltd
2348 Yukon Street
Vancouver, BC V5Y 3T6
T 604.872.1211
Building Code Consultant
LMDG (Allan Arcangel)
Level 4-780 Beatty Street
Vancouver, BC V6B 2M1
T 604.682.7149
Interior Design/ Furniture Consultant
34F Design Inc (Erica Wickes)
525-119 West Pender Street
Vancouver, BC V6B 1S5
T 604.620.8182
C 604.314.7197
FINISH LEGEND GENERAL ITEMS
B1 RUBBER BASE- CHARCOAL 4-1/2" TALL COLOUR- AS SPECIFIED
C1 SMOOTH GYPSUM BOARD. PATCH AND PREPARE TO RECIEVE PAINT
EXG EXISTING
GL GLAZING
GWB GYPSUM BOARD and WATER-RESISTANT GYPSUM BOARD
PT-4
PAINT - GENERAL PAINT-(1516N ORANGE) (CUBS CORNER ACCENT COLOUR)
PT-5
PAINT - GENERAL PAINT-(1139N LIME) (RAVENS NEST ACCENT COLOUR)
PT-6
PAINT - GENERAL PAINT-(1124A YELLOW) (PORCUPINE PALS COLOUR)
PT-10
PAINT - GENERAL PAINT- (LEAD CL3175A) (EXTERIOR TRIM COLOUR)
FL-2 INTERFACE CARPET TILE 'THE STANDARD' 9361 MANGROVE
FL-5
TYPICAL LOCATION USED
TO BE APPLIED AS REQUIRED THROUGHOUT PROJECT
WATER RESISTANT GWB USED IN WET AREAS- SUITE SHOWER/ TUB SURROUND
TYPICAL CARPET TILE WHERE CARPET IS SCHEDULED FOR REPLACEMENT
ACTIVITY ROOM EXTERIOR ENTRY + MAIN FOYER AND CORRDORINTERFACE WALK-OFF MAT - 'ENTRY LEVEL' - 7187 BLACK
NEW RUBBER BASE: FOR ALL AREAS WHERE FLOORING IS SCHEDULED FOR REPLACEMENT
AND LOCATIONS WHERE EXISTING FLOORING IS REMAINING -UNO.
PT-1
PAINT - BENJAMIN MOORE - SILVER SATIN OC-26 (WARM OFF-WHITE)TYPICAL FIELD COLOUR FOR COMMON AREA WALLS AND CEILINGS.
GENERAL AREAS ROOM FINISH SCHEDULE
ROOM # ROOM NAME
FLOOR
FINISH BASE FINISH
NORTH EAST SOUTH WEST CEILING
FINISH NOTESMATERIAL FINISH MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH
MAIN
VESTIBULE
FL-5 B1 EXG / GWB PT-1 GWB PT-1 GWB PT-1 EXG PT-1 C1 PT-1
103 OFFICE EXG PT-1 EXG PT-1 EXG PT-1 EXG PT-1 PT-1
VEST 101
PT-3
PAINT - DULUX - MANSARD STONE (CHARCOAL)
INTERIOR - ALL DOOR FRAMES AND ACCENT WALL LOCATIONS
FL-4
ARMSTRONG 'MENDITONE' - COLOUR 1 CUBS CORNER- TBA
- COLOUR 2 RAVENS NEST- TBA
- COLOUR 3 POCUPINE PALS- TBA
TYPICAL SHEET FLOORING (ACCENT COLOURS)
CUBS CORNER POD 107
ROOM # ROOM NAME
FLOOR
FINISH BASE FINISH
NORTH EAST SOUTH WEST CEILING
FINISH NOTESMATERIAL FINISH MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH
105 KITCHEN EXG EXG PT-3 / BB2 EXG* PT-3 / BB2* EXG PT-3 / BB2 EXG* PT-3 / BB2* C1 PT-1 *AS APPLICABLE- REFER TO A7.10
106 CUBBIES EXG EXG EXG EXG C1 PT-1
107 ACTIVITY ROOM EXG C1 PT-1
109 SLEEP ROOM EXG EXG EXG EXG EXG
110 WC EXG EXG PT-1 EXG PT-1 EXG PT-1 EXG FF* EXG PT-1
*PT-5 ON CORRIDOR SIDE ALSO, REFER TO MILLWORK
111 LAUNDRY EXG EXG EXG PT-1 EXG PT-1 EXG PT-1 EXG PT-1 EXG PT-1
*AS APPLICABLE- REFER TO A7.10
*AS APPLICABLE- REFER TO A7.10
EXG PT-5/ PT3* PT-5/ PT3* PT-5/ PT3* PT-5/ PT3*
EXG EXG EXG
EXGPT-1/PT-3PT-1/PT-3 PT-1/PT-3 PT-1/PT-3
INTERIOR - PORCUPINE PALS- ACTIVITY ROOM 130 ACCENT COLOUR
EXTERIOR- TRIM COULOUR- ALLL TEAL/BLUE BITS ON EXTERIOR (ALL
EXCEPT STUCCO)
102 MAIN CORRIDOR
104 STAFF ROOM
113 SICK ROOM
114 MECHANICAL
115 JANITORIAL
123 STAFF WC
124 STAFF WC
FL-5
EXG
B1 EXG PT-1 EXG PT-1 PT-1EXG EXG PT-1 PT-1
EXG PT-1 EXG PT-1 EXG PT-1 EXG PT-1 PT-1
EXG PT-1 EXG PT-1 EXG PT-1 EXG PT-1 PT-1
EXG EXG EXG EXG
EXG PT-1 EXG PT-1 EXG PT-1 EXG PT-1 PT-1
EXG PT-1 EXG PT-1 EXG PT-1 EXG PT-1 PT-1
EXG PT-1 EXG PT-1 EXG PT-1 EXG PT-1 PT-1
112STORAGE/
OFFICE
EXG PT-1 EXG PT-1 EXG PT-1 EXG PT-1 EXG / C1 PT-1
FL-2 (BR only)
B1
EXG
REPLACE BR (BEDROOM) CARPET ONLY
EXG
C1
C1
C1
C1
C1C1
C1
C1
EXISTING CARPET TO REMAIN
108 SLEEP ROOM EXG EXG EXG EXG EXGFL-2
FL-4 (kitch)
B1PT-1 PT-3 PT-1 PT-1
EXG
APPLY FROSTED FILM TO PORTION OF GLASS TO
CONCEAL ETS EQUIPMENT. PROVIDE WINDOW VIEW AND
EDUCATIONAL WRITE UP.
REMOVE EQUIPMENT - SEE MECH. AND RELOCATE MOP
SINK. ADD FRP TO 2WALLS BEHIND MOP SINK TO 48" AFF.
B1
B1
B1
B1
B1
PT-1 PT-1PT-1 PT-1 PT-1
FL-4
PT-3 ON HANDRAILS
B1
EXG
EXG
EXG
EXG EXG
EXGEXG EXGEXGEXG EXG EXGC1
EXISTING FLOOR TO REMAIN
EXGEXGPATCH AND PAINT AREA WHERE MOP SINK HAS BEEN
REMOVED
EXGEXG
EXGEXG
RAVENS NEST POD 118
ROOM # ROOM NAME
FLOOR
FINISH BASE FINISH
NORTH EAST SOUTH WEST CEILING
FINISH NOTESMATERIAL FINISH MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH
116 STOR/ OFFICE EXG EXG PT-3 / BB2 EXG* PT-3 / BB2* EXG PT-3 / BB2 EXG* PT-3 / BB2* C1 PT-1 *AS APPLICABLE- REFER TO A7.10
117 KITCHEN EXG EXG EXG EXG C1 PT-1
118 ACTIVITY ROOM EXG C1 PT-1
120 WC EXG EXG EXG EXG EXG
121 LAUNDRY EXG EXG PT-1 EXG PT-1 EXG PT-1 EXG FF* EXG PT-1
*PT-5 ON CORRIDOR SIDE ALSO, REFER TO MILLWORK
122 CUBBIES EXG EXG EXG PT-1 EXG PT-1 EXG PT-1 EXG PT-1 EXG PT-1
*AS APPLICABLE- REFER TO A7.10
*AS APPLICABLE- REFER TO A7.10
EXG PT-5/ PT3* PT-5/ PT3* PT-5/ PT3* PT-5/ PT3*
EXG EXG EXG
EXGPT-1/PT-3PT-1/PT-3 PT-1/PT-3 PT-1/PT-3
119 NAP ROOM EXG EXG EXG EXG EXGFL-2 B1PT-1 PT-3 PT-1 PT-1
B1
B1
B1
B1
B1
PT-1 PT-1PT-1 PT-1 PT-1
FL-4
PT-3 ON HANDRAILS
PORCUPINE POD 130
ROOM # ROOM NAME
FLOOR
FINISH BASE FINISH
NORTH EAST SOUTH WEST CEILING
FINISH NOTESMATERIAL FINISH MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH
125 CUBBIES EXG EXG PT-3 / BB2 EXG* PT-3 / BB2* EXG PT-3 / BB2 EXG* PT-3 / BB2* C1 PT-1 *AS APPLICABLE- REFER TO A7.10
126 LAUNDRY EXG EXG EXG EXG C1 PT-1
127 WC EXG C1 PT-1
129 STOR./OFFICE EXG EXG EXG EXG EXG
130 ACTIVITY ROOM EXG EXG PT-1 EXG PT-1 EXG PT-1 EXG FF* EXG PT-1
*PT-5 ON CORRIDOR SIDE ALSO, REFER TO MILLWORK
131 NAP ROOM EXG EXG EXG PT-1 EXG PT-1 EXG PT-1 EXG PT-1 EXG PT-1
*AS APPLICABLE- REFER TO A7.10
*AS APPLICABLE- REFER TO A7.10
EXG PT-5/ PT3* PT-5/ PT3* PT-5/ PT3* PT-5/ PT3*
EXG EXG EXG
EXGPT-1/PT-3PT-1/PT-3 PT-1/PT-3 PT-1/PT-3
128 KITCHEN EXG EXG EXG EXG EXGFL-2
FL-4 (kitch)
B1PT-1 PT-3 PT-1 PT-1
B1
B1
B1
B1
B1
PT-1 PT-1PT-1 PT-1 PT-1
FL-4
PT-3 ON HANDRAILS
B1
INTERIOR - RAVENS NEST -ACTIVITY ROOM 118 ACCENT COLOUR
INTERIOR - CUBS CORNER -ACTIVITY ROOM 107 ACCENT COLOUR
FL-3ARMSTRONG 'MENDITONE' - H5306 NATURAL GREY DARK
TYPICAL SHEET FLOORING (FIELD COLOUR)
HCMA Architecture + Design
400 - 675 West Hastings Street
Vancouver BC V6B 1N2 Canada
T 604.732.6620
W hcma.ca
Copyright reserved. These drawings and the design contained therein or which may be inferred therefrom are, and at all times remain, the exclusive property of HCMA Architecture + Design (HCMA). HCMA holds the copyright and ownership in the said drawings, which cannot be used for any purpose without the express written consent of HCMA.
CHECKED: DRAWN:PROJECT # 1669 IM DP
ISSU
ED
FO
R CO
ORD
IN
ATIO
N
NO
VEM
BER.5.2016
ISSU
ED
FO
R 90%
CO
ORD
IN
ATIO
ND
ECEM
BER 22.2016
--
--
--
--
--
--
--
--
DA
TE
:
SC
AL
E:
6
NTS
FINISHES LEGEND
FIN
IS
H_S
CH
ED
UL
ES
AS
SE
MB
LIE
S
JA
NU
AR
Y.1
2.2
01
7
1:1
00
A9.00
UN
BC
-S
TU
DE
NT
-H
OU
SIN
G
KE
YO
H_R
ES
ID
EN
CE
+C
HIL
DC
AR
E
PORCUPINE
PALS
130
RAVEN'S
NEST
118
CUB'S
CORNER
107
NAP / GROSS
MOTOR
131
STOR. / OFFICE
OBSERV.
129
KITCHEN
128
CUBBIES
125
CUBBIES
122
LAUNDRY
126
LAUNDRY
121
WASHROOM
127
WASHROOM
120
KITCHEN
117
STAFF
HC WASH.
123
STAFF
HC WASH.
124STOR. / OFFICE
OBSERV.
116
CORRIDOR
102
STAFF ROOM
104
OFFICE
103
SLEEP
108
VESTIBULE
101
SLEEP
109
NAP / GROSS
MOTOR
119
LAUNDRY
111
STOR. / OFFICE
OBSERVE
112
SICK ROOM
113
MECH
114
JAN.
115
CUBBIES
106
KITCHEN
105
WASHROOM
110
1
1:60
LEVEL 1 - UNBC CHILDCARE FLOOR PLAN/ SITE PLAN
N
Copyright reserved. These drawings and the design contained therein or which may be inferred therefrom are, and at all times remain, the exclusive property of HCMA Architecture + Design (HCMA). HCMA holds the copyright and ownership in the said drawings, which cannot be used for any purpose without the express written consent of HCMA. CHECKED: DRAWN:PROJECT # 1669 IM DP
REN
OVATIO
NS
KE
YO
H-R
ES
ID
EN
CE
+C
HIL
DC
AR
E
UN
BC
-S
TU
DE
NT
-H
OU
SIN
G
A9.01
1:6
0
JA
NU
AR
Y.2
5.2
01
7
FL
OO
R_P
LA
N
DA
TE
:
SC
AL
E:
ISSU
ED
FO
R AD
DEN
DU
M 1
JAN
UARY 25, 2017
--
--
--
--
--
--
--
--
--
HCMA Architecture + Design
400 - 675 West Hastings Street
Vancouver BC V6B 1N2 Canada
T 604.732.6620
W hcma.ca
N
SOUTH
DAYCARE KEYPLAN
UN
BC
-C
HIL
DC
AR
E
NORTH
TENDER T16-1613 RESIDENCE II INTERIOR RENOVATION: TRADES
Addendum #1 – Childcare Separate Pricing Schedule
SCHEDULE I PROPONENT SUBMISSION CHECK LIST
TENDER T16-1613
This separate pricing schedule is for the Childcare facility beside the Residence 2. Proponents are asked to identify the below division they are providing the separate pricing for and complete schedule II, schedule II(A) and Schedule II(B) if applicable. UNBC and the Construction Manager reserve the right to award or not award any or all of the scope of work to multiple vendors.
YES NO
Division 08 Doors and Frames Trade Package ____ ____
Division 09a Drywall Trade Package ____ ____
Division 09b Painting Trade Package ____ ____
Division 09c Flooring Trade Package ____ ____
Division 12 Window Coverings Trade Package ____ ____
Division 15 Mechanical Trade Package ____ ____
Division 16 Electrical Trade Package ____ ____
1. Schedule II – Stipulated Sum Price ____ ____
2. Schedule II(A) – Separate Price List ____ ____
3. Schedule II(B) – Alternate Price List [OPTIONAL] ____ ____
DO NOT DELIVER, MAIL, COURIER, FAX or EMAIL your quote to the University. It must be submitted electronically through Bonfire.
TENDER T16-1613 RESIDENCE II INTERIOR RENOVATION: TRADES
Addendum #1 – Childcare Separate Pricing Schedule
SCHEDULE II STIPULATED SUM PRICE
TENDER T16-1613
Quotations shall be itemized as indicated and as described in Appendix A. Please do not submit hand written responses on the forms provided. Schedules are posted in Word along with PDF version of the Tender. For alternative bids (in addition to required base bid), please submit a separate Schedule II(B), complete along with appropriate submittal sheet, label as alternative and submit up to three through Bonfire. UNBC and the Construction Manager reserve the right to award or not award any or all of this scope of work to multiple vendors. I/We hereby have read all bid documents and hereby offer to perform the work in accordance with the bid documents for the stipulated bid price of:
ITEM QUANTITY DESCRIPTION STIPULATED SUM PRICE
1 1 Childcare Facility $ Subtotal $ GST $ PST $ Total $
TENDER T16-1613 RESIDENCE II INTERIOR RENOVATION: TRADES
Addendum #1 – Childcare Separate Pricing Schedule
SCHEDULE II(A) SEPARATE PRICE LIST
TENDER T16-1613
Quotations shall be itemized as indicated and as described in Appendix A. Please do not submit hand written responses on the forms provided. Schedules are posted in Word along with PDF version of the Tender. For alternative bids (in addition to required base bid), please submit a separate Schedule II(B), complete along with appropriate submittal sheet, label as alternative and submit up to three through Bonfire. UNBC and the Construction Manager reserve the right to award any or all of the scope of work to multiple vendors. I/We hereby have read all bid documents and hereby offer to perform the Separate Price work in accordance with the bid documents for the stipulated bid price of:
ITEM QUANTITY DESCRIPTION SEPARATE PRICE
1 1 Separate Price - Flooring $
Subtotal
GST $ PST $ Total $
TENDER T16-1613 RESIDENCE II INTERIOR RENOVATION: TRADES
Addendum #1 – Childcare Separate Pricing Schedule
SCHEDULE IV: MANPOWER, RESOURCES AND MANHOURS Page 1 of 2
SCHEDULE II(B) ALTERNATE PRICE LIST
TENDER T16-1613
Quotations shall be itemized as indicated and as described in Appendix A. Please do not submit hand written responses on the forms provided. Schedules are posted in Word along with PDF version of the Tender. I/We hereby have read all bid documents and hereby offer to perform the work in accordance with the bid documents, with alternatives as described below, for the stipulated bid price of:
ITEM QUANTITY DESCRIPTION ALTERNATE STIPULATED SUM PRICE
N/A N/A N/A $
Subtotal $ GST $ PST $ Total $