university of new england (une) - une entry signage · 2013. 11. 19. · remove existing sign. ©...
TRANSCRIPT
Drawing Size© Dot Dash Pty Ltd ACN 010 951 443 Telephone +617 3896 6600 Facsimile +617 3896 662086 Lytton Road PO Box 7480 East Brisbane Queensland 4169 Australia
IssueDate Status Drawing No Sheet
Printed at A3 E09.09.10 For Tender not for production
UNIVERSITY OF NEW ENGLAND • Entry Statement Signs
4563.SL1 1 of 1
SIGN LOCATION PLAN • Main Entry Sign
Unless otherwise noted all dimensions in millimetres. Use figured dimensions in preference to scaling. Contractor to confirm all dimensions and details on site prior to manufacture.
North
0 10m5m
Plan Detail - Main EntryScale 1:200
New Sign 1B
Align to Sign 1A
Maintain sign withinLands Depart. cadastre lineSign to not encroach site line clearance zone
Remove existing sign
Align to LandsDepartment
cadastre line
Elm Avenue
New Sign 1A
3000
3000
FOR TENDER
Power supply from existingground mounted light fitting.Remove existing light and install pit
Under bore ø100mm conduitand 1 x spare ø100mm conduitunder road only
EQapprox. 5000
Sign to notencroach site line clearance zone EP
EP
EP
TOWN WATER SUPPLY
EXISTING SERVICES
NEW SERVICES
COMMUNICATIONS
WATER SUPPLY
SEWER
HV BURIED ELECTRICITY
LOW VOLTAGE ELECTRICITY
LEGEND
GAS
T
H
LANDS DEPT. CADASTRE
BOUNDARY SURVEY
SITE LINE 5m CLEAR ZONE
TYPE 5 ELECTRICAL PIT
ELECTRICAL CONDUIT
EP
HV OVERHEAD ELECTRICITY
EQapprox. 5000
Drawing Size© Dot Dash Pty Ltd ACN 010 951 443 Telephone +617 3896 6600 Facsimile +617 3896 662086 Lytton Road PO Box 7480 East Brisbane Queensland 4169 Australia
IssueDate Status Drawing No Sheet
Printed at A3 D26.05.10 For Tender not for production
UNIVERSITY OF NEW ENGLAND • Entry Statement Signs
4563A.ID1 1 of 5
SIGN TYPE DRAWING • Main Entry Sign
Unless otherwise noted all dimensions in millimetres. Use figured dimensions in preference to scaling. Contractor to confirm all dimensions and details on site prior to manufacture.
AttentionDue to this reproduction process the colours in this image are not exact representations of the final product.
GENERAL CONSTRUCTION NOTES• It is the Signmakers responsibility to refer to the - Sign specifications- Sign location plan
• Drawings show design intent. Any changes to specification which affects design intent must be approved by Dot Dash.
• All structural members, fixings and/or footings to be confirmed by sign maker’s engineer.
• Signmaker to confirm all details for approval on shop drawings prior to manufacture.
• Signmaker to provide and install survey boundary pegs prior to set out of signage. Final set out of signage to be agreed onsite with client.
• Signmaker to provide protection for all surrounding trees at all times during the construction period. Safety measures need to be put into place for this protection.
Refer to sheet 2 for Graphics Detail
Refer to sheets 2 to 4 for Construction Details
FOR TENDER
SIGN 1BSIGN 1A
TOP VIEW
INDICATIVE PLACEMENT - REFER TO SIGN LOCATION PLAN FOR SETOUT
SIDE 1
SIDE 1
SIDE VIEW
SIDE VIEW
SIDE 2
SIDE 2
Combined View - Day TimeScale 1:100
ELM
AV
EN
UE
QUEEN ELIZABETH DRIVE ENTRY
Combined View - Night TimeScale 1:100
SIDE 2 SIDE 1 SIDE 2 SIDE 1
Panel 1Panel 3
Panel 2
Panel 1Panel 3
Panel 2
Drawing Size© Dot Dash Pty Ltd ACN 010 951 443 Telephone +617 3896 6600 Facsimile +617 3896 662086 Lytton Road PO Box 7480 East Brisbane Queensland 4169 Australia
IssueDate Status Drawing No Sheet
Printed at A3 D26.05.10 For Tender not for production
UNIVERSITY OF NEW ENGLAND • Entry Statement Signs
4563A.ID1 2 of 5
SIGN TYPE DRAWING • Main Entry Sign
Unless otherwise noted all dimensions in millimetres. Use figured dimensions in preference to scaling. Contractor to confirm all dimensions and details on site prior to manufacture.
GENERAL CONSTRUCTION NOTES• It is the Signmakers responsibility to refer to the - Sign specifications- Sign location plan
• Drawings show design intent. Any changes to specification which affects design intent must be approved by Dot Dash.
• All structural members, fixings and/or footings to be confirmed by sign maker’s engineer.
• Signmaker to confirm all details for approval on shop drawings prior to manufacture.
Graphics DetailPANEL COLOURSa. Stainless steel = No.4 polished linish finish on all visible surfaces, vertical grain. Micro polished.
b. Colourback glass = Translucent ceramic paint to match Pantone 376C
c. Kickplate = to match Dulux ‘Luck’ PG1G9
Construction Details - Footing and Pavement1. Re-inforced concrete pad/pier footing to engineers specification. Cast-in hold down bolts to align with base plates.
2. Pattern coloured concrete pavement around base of sign. CCS Storm Grey Hardener, Black Release Agent, Royal Ashlar Mat or similar (Concrete Colour Systems 07 3287 6444). Finished level of pavement to follow natural slope of ground.
3. Power feeds in conduits cast in footing to connect to electrical pits, refer to plans for power supply source.
All electrical work (conduits, pits etc) from sign to power source is to be included in this scope of works. Refer to specification for preferred Electrical Contractors list.
Construction Details Refer to sheet 3 for Panels 1 & 3 detailsRefer to sheet 4 for Panel 2 details
FOR TENDER
PANEL 1 - SIDE 1 & PANEL 3 - SIDE 2 PANEL 2 - BOTH SIDES
TOP VIEW
SIDE VIEW
Panel Layouts - SIgn 1A & 1BScale 1:50
3
22
1 1 11
3000
100
min
3000
PANEL 1 - SIDE 2 & PANEL 3 - SIDE 1
3000
100
min
3000
1497 6 1497
Panel 1
Panel 3
SIDE 1
SIDE 2
Panel 2
3000
10001000
1000
1000
3000
206 600 206 600 206
aa b
cc
2
21
300
min
PAVEMENT EXAMPLE
FABRICATED STAINLESS STEEL FORMS
PANEL 1 - SIDE 1 & PANEL 3 - SIDE 2 PANEL 1 - SIDE 2 & PANEL 3 - SIDE 1
Drawing Size© Dot Dash Pty Ltd ACN 010 951 443 Telephone +617 3896 6600 Facsimile +617 3896 662086 Lytton Road PO Box 7480 East Brisbane Queensland 4169 Australia
IssueDate Status Drawing No Sheet
Printed at A3 D26.05.10 For Tender not for production
UNIVERSITY OF NEW ENGLAND • Entry Statement Signs
4563A.ID1 5 of 5
SIGN TYPE DRAWING • Main Entry Sign
Unless otherwise noted all dimensions in millimetres. Use figured dimensions in preference to scaling. Contractor to confirm all dimensions and details on site prior to manufacture.
Refer to sheets 2 to 4 for Construction Details
Refer to sheet 2 for Graphics Detail
FOR TENDERQUEEN ELIZABETH DRIVE - VIEW FROM EAST QUEEN ELIZABETH DRIVE - VIEW FROM WEST
QUEEN ELIZABETH DRIVE - VIEW FROM EAST
Remove existing sign
Drawing Size© Dot Dash Pty Ltd ACN 010 951 443 Telephone +617 3896 6600 Facsimile +617 3896 662086 Lytton Road PO Box 7480 East Brisbane Queensland 4169 Australia
IssueDate Status Drawing No Sheet
Printed at A3 F10.09.10 For Tender not for production
UNIVERSITY OF NEW ENGLAND • Entry Statement Signs
4563.SL2 1 of 1
SIGN LOCATION PLAN • Magwick Drive Entry Sign
Unless otherwise noted all dimensions in millimetres. Use figured dimensions in preference to scaling. Contractor to confirm all dimensions and details on site prior to manufacture.
North
0 10m 20m 30m
FOR TENDER
TOWN WATER SUPPLY
EXISTING SERVICES
NEW SERVICES
COMMUNICATIONS
WATER SUPPLY
SEWER
HV BURIED ELECTRICITY
LOW VOLTAGE ELECTRICITY
LEGEND
GAS
T
H
LANDS DEPT. CADASTRE
BOUNDARY SURVEY
TYPE 5 ELECTRICAL PIT
ELECTRICAL CONDUIT
EP
HV OVERHEAD ELECTRICITY
Plan Detail - Magwick Drive EntryScale 1:500
Final location to be determinedby survey in consideration to servicesand tree protection zone. Approval to be sought from Council’s Civic and Recreation services andDevelopment Engineer.
New Sign 2A
Align to Sign 2A
Align to boundary line
Align to boundary line
trim lower section of existing treeto improve sightlines
Under bore ø100mm conduitand 1 x spare ø100mm conduitunder road only
Power supply to come from existing light pole supply
Under bore ø100mmconduit and 1 x spare
ø100mm conduitunder road only
New Sign 2B
approx. 12600
EP
EP
EP
EP
Drawing Size© Dot Dash Pty Ltd ACN 010 951 443 Telephone +617 3896 6600 Facsimile +617 3896 662086 Lytton Road PO Box 7480 East Brisbane Queensland 4169 Australia
IssueDate Status Drawing No Sheet
Printed at A3 D26.05.10 For Tender not for production
UNIVERSITY OF NEW ENGLAND • Entry Statement Signs
4563A.ID2 1 of 3
SIGN TYPE DRAWING • Magwick Drive Entry Sign
Unless otherwise noted all dimensions in millimetres. Use figured dimensions in preference to scaling. Contractor to confirm all dimensions and details on site prior to manufacture.
AttentionDue to this reproduction process the colours in this image are not exact representations of the final product.
GENERAL CONSTRUCTION NOTES• It is the Signmakers responsibility to refer to the - Sign specifications- Sign location plan
• Drawings show design intent. Any changes to specification which affects design intent must be approved by Dot Dash.
• All structural members, fixings and/or footings to be confirmed by sign maker’s engineer.
• Signmaker to confirm all details for approval on shop drawings prior to manufacture.
• Signmaker to provide and install survey boundary pegs prior to set out of signage. Final set out of signage to be agreed onsite with client.
• Signmaker to provide protection for all surrounding trees at all times during the construction period. Safety measures need to be put into place for this protection.
Refer to sheet 2 for Graphics Detail and Panel Layouts
Refer to Drawing 4563A.ID1 sheets 3 & 4 for Construction Details
FOR TENDER
TOP VIEW
INDICATIVE PLACEMENT - REFER TO SIGN LOCATION PLAN FOR SETOUT
Typical ground slope - confirm on site
MAGWICK DRIVE ENTRY
SIDE VIEW
SIDE 1
SIDE 2
SIDE 1
SIDE 2
Panel 1
Panel 2
Panel 3
Panel 1
Panel 2
Panel 3
3000
3000
3000
3000
350
50
SIDE VIEW
Combined View - Day TimeScale 1:100
Combined View - Night TimeScale 1:100
SIGN 2B
SIGN 2B
SIGN 2B
SIGN 2A
SIGN 2A
SIGN 2A
Drawing Size© Dot Dash Pty Ltd ACN 010 951 443 Telephone +617 3896 6600 Facsimile +617 3896 662086 Lytton Road PO Box 7480 East Brisbane Queensland 4169 Australia
IssueDate Status Drawing No Sheet
Printed at A3 D26.05.10 For Tender not for production
UNIVERSITY OF NEW ENGLAND • Entry Statement Signs
4563A.ID2 2 of 3
SIGN TYPE DRAWING • Magwick Drive Entry Sign
Unless otherwise noted all dimensions in millimetres. Use figured dimensions in preference to scaling. Contractor to confirm all dimensions and details on site prior to manufacture.
GENERAL CONSTRUCTION NOTES• It is the Signmakers responsibility to refer to the - Sign specifications- Sign location plan
• Drawings show design intent. Any changes to specification which affects design intent must be approved by Dot Dash.
• All structural members, fixings and/or footings to be confirmed by sign maker’s engineer.
• Signmaker to confirm all details for approval on shop drawings prior to manufacture.
Graphics DetailPANEL COLOURSa. Stainless steel = No.4 polished linish finish on all visible surfaces, vertical grain. Micro polished.
b. Colourback glass = Translucent ceramic paint to match Pantone 376C
c. Kickplate = to match Dulux ‘Luck’ PG1G9
Construction Details - Footing and Pavement1. Re-inforced concrete pad/pier footing to engineers specification. Cast-in hold down bolts to align with base plates.
2. Pattern coloured concrete pavement around base of sign. CCS Storm Grey Hardener, Black Release Agent, Royal Ashlar Mat or similar (Concrete Colour Systems 07 3287 6444). Finished level of pavement to follow natural slope of ground.
3. Power feeds in conduits cast in footing to connect to electrical pits, refer to plans for power supply source.
All electrical work (conduits, pits etc) from sign to power source is to be included in this scope of works. Refer to specification for preferred Electrical Contractors list.
Construction Details Refer to Drawing 4563A.ID1 sheet 3 for Panels 1 & 3 detailsRefer to Drawing 4563A.ID1 sheet 4 for Panel 2 details
FOR TENDER
PANEL 1 - SIDE 1 & PANEL 3 - SIDE 2 PANEL 2 - BOTH SIDES
TOP VIEW
SIDE VIEW
Panel LayoutsScale 1:50
2
1 1 11
3000
3000
PANEL 1 - SIDE 2 & PANEL 3 - SIDE 1
3000
3000
1497 6 1497
Panel 1
Panel 3
SIDE 1
SIDE 2
Panel 2
3000
10001000
1000
1000
3000
206 600 206 600 206
aa b
2
21
300
min
c
2
Kick plate height (minimum)50mm for Sign 2B350mm for Sign 2A
Typical ground slopeconfirm on site
PAVEMENT EXAMPLE
FABRICATED STAINLESS STEEL FORMS
PANEL 1 - SIDE 1 & PANEL 3 - SIDE 2 PANEL 1 - SIDE 2 & PANEL 3 - SIDE 1
Drawing Size© Dot Dash Pty Ltd ACN 010 951 443 Telephone +617 3896 6600 Facsimile +617 3896 662086 Lytton Road PO Box 7480 East Brisbane Queensland 4169 Australia
IssueDate Status Drawing No Sheet
Printed at A3 D26.05.10 For Tender not for production
UNIVERSITY OF NEW ENGLAND • Entry Statement Signs
4563A.ID2 3 of 3
SIGN TYPE DRAWING • Magwick Drive Entry Sign
Unless otherwise noted all dimensions in millimetres. Use figured dimensions in preference to scaling. Contractor to confirm all dimensions and details on site prior to manufacture.
Refer to Sheet 2 for Construction Details Refer to sheet 1 for Graphics Detail
FOR TENDER
VIEW FROM EAST
VIEW FROM WEST
Remove existing sign