Double (70 mil) or Quad (50 mil) Density Grid 4-Wire Measurement Long Pin Fixtures 95 mm / 3,75” Test Area up to 406 mm x 325 mm / 16.0” x 12.8”
A3030 Universal Grid Test System
Data Preparation External generation with established fixture building program (e.g. ADAM II)
Fault Location Fault location and verification is done in CAR II or on an atg flying prober
Option Retractable guide rails 4-Wire Measurement 10 mΩ to 100 Ω
Power supply 400 V, 50 / 60 Hz, 3500 VACompressed air 6-8 bar, about 90 psi (dried and filtered)Temperature 18 °C - 27 °C (64 °F - 77 °F)Relative humidity 40 % - 60 % (10 MOhm) 45 % - 55 % (100 MOhm)Machine weight About 2045 kg / 4508 lbs
All information subject to change without notice! May 2015
Test Field Size
Maximum (X x Y) 406 mm x 325 mm / 16.0” x 12.8” DD (70 mil) or QD (50 mil)
ValuGrid® long pin fixture, 95 mm / 3,75”, both sides
Board Handling
Minimum board size (X x Y) 50 mm x 50 mm / 2.0” x 2.0”Maximum board size (X x Y) 460 mm x 335 mm / 18.1” x 13.2”Maximum board thickness 4 mmMinimum board thickness - manual testing 0.1 mm / 0.0039”- automatic testing 0.6 mm / 0.023”
Test Points
QD 16.0” x 12.8” 81.920 test points with 40.960 test channels per side
Test Parameters
Test voltage 40 V - 250 V DCContinuity threshold 10 Ω - 10 kΩIsolation threshold 100 kΩ - 100 MΩEmbedded Resistor Measurement 1 Ω to 10 kΩ
A3030 Technical SpecificationsUniversal Grid Test System