unit 3 pump #1 07-10-17 - maintenance · page16 date:7/10/2017 3:44 pm machine setup details...

15
Page2 Date:7/10/2017 3:44 PM Location : Location 1 Range : High range Axis : Axial X Axis Unit : Orders Y Axis Unit : mm/sec 1X RPM : 1782 RPM Location : Location 1 Range : Low range Axis : Axial X Axis Unit : Orders Y Axis Unit : mm/sec 1X RPM : 1780 RPM

Upload: others

Post on 10-Jul-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Unit 3 Pump #1 07-10-17 - Maintenance · Page16 Date:7/10/2017 3:44 PM Machine Setup Details Machine Setup Name : CLG H2O 1 UNIT3 Setup Field Input Motor type AC AC motor with VFD

Page2

Date:7/10/2017 3:44 PMLocation : Location 1Range : High rangeAxis : AxialX Axis Unit : OrdersY Axis Unit : mm/sec1X RPM : 1782 RPM

Location : Location 1Range : Low rangeAxis : AxialX Axis Unit : OrdersY Axis Unit : mm/sec1X RPM : 1780 RPM

Page 2: Unit 3 Pump #1 07-10-17 - Maintenance · Page16 Date:7/10/2017 3:44 PM Machine Setup Details Machine Setup Name : CLG H2O 1 UNIT3 Setup Field Input Motor type AC AC motor with VFD

Page3

Date:7/10/2017 3:44 PMLocation : Location 1Range : High rangeAxis : TangentialX Axis Unit : OrdersY Axis Unit : mm/sec1X RPM : 1782 RPM

Location : Location 1Range : Low rangeAxis : TangentialX Axis Unit : OrdersY Axis Unit : mm/sec1X RPM : 1782 RPM

Page 3: Unit 3 Pump #1 07-10-17 - Maintenance · Page16 Date:7/10/2017 3:44 PM Machine Setup Details Machine Setup Name : CLG H2O 1 UNIT3 Setup Field Input Motor type AC AC motor with VFD

Page4

Date:7/10/2017 3:44 PMLocation : Location 1Range : High rangeAxis : RadialX Axis Unit : OrdersY Axis Unit : mm/sec1X RPM : 1782 RPM

Location : Location 1Range : Low rangeAxis : RadialX Axis Unit : OrdersY Axis Unit : mm/sec1X RPM : 1783 RPM

Page 4: Unit 3 Pump #1 07-10-17 - Maintenance · Page16 Date:7/10/2017 3:44 PM Machine Setup Details Machine Setup Name : CLG H2O 1 UNIT3 Setup Field Input Motor type AC AC motor with VFD

Page5

Date:7/10/2017 3:44 PMLocation : Location 2Range : High rangeAxis : AxialX Axis Unit : OrdersY Axis Unit : mm/sec1X RPM : 1800 RPM

Location : Location 2Range : Low rangeAxis : AxialX Axis Unit : OrdersY Axis Unit : mm/sec1X RPM : 1780 RPM

Page 5: Unit 3 Pump #1 07-10-17 - Maintenance · Page16 Date:7/10/2017 3:44 PM Machine Setup Details Machine Setup Name : CLG H2O 1 UNIT3 Setup Field Input Motor type AC AC motor with VFD

Page6

Date:7/10/2017 3:44 PMLocation : Location 2Range : High rangeAxis : TangentialX Axis Unit : OrdersY Axis Unit : mm/sec1X RPM : 1785 RPM

Location : Location 2Range : Low rangeAxis : TangentialX Axis Unit : OrdersY Axis Unit : mm/sec1X RPM : 1780 RPM

Page 6: Unit 3 Pump #1 07-10-17 - Maintenance · Page16 Date:7/10/2017 3:44 PM Machine Setup Details Machine Setup Name : CLG H2O 1 UNIT3 Setup Field Input Motor type AC AC motor with VFD

Page7

Date:7/10/2017 3:44 PMLocation : Location 2Range : High rangeAxis : RadialX Axis Unit : OrdersY Axis Unit : mm/sec1X RPM : 1778 RPM

Location : Location 2Range : Low rangeAxis : RadialX Axis Unit : OrdersY Axis Unit : mm/sec1X RPM : 1780 RPM

Page 7: Unit 3 Pump #1 07-10-17 - Maintenance · Page16 Date:7/10/2017 3:44 PM Machine Setup Details Machine Setup Name : CLG H2O 1 UNIT3 Setup Field Input Motor type AC AC motor with VFD

Page8

Date:7/10/2017 3:44 PMLocation : Location 3Range : High rangeAxis : AxialX Axis Unit : OrdersY Axis Unit : mm/sec1X RPM : 1780 RPM

Location : Location 3Range : Low rangeAxis : AxialX Axis Unit : OrdersY Axis Unit : mm/sec1X RPM : 1780 RPM

Page 8: Unit 3 Pump #1 07-10-17 - Maintenance · Page16 Date:7/10/2017 3:44 PM Machine Setup Details Machine Setup Name : CLG H2O 1 UNIT3 Setup Field Input Motor type AC AC motor with VFD

Page9

Date:7/10/2017 3:44 PMLocation : Location 3Range : High rangeAxis : TangentialX Axis Unit : OrdersY Axis Unit : mm/sec1X RPM : 1781 RPM

Location : Location 3Range : Low rangeAxis : TangentialX Axis Unit : OrdersY Axis Unit : mm/sec1X RPM : 1780 RPM

Page 9: Unit 3 Pump #1 07-10-17 - Maintenance · Page16 Date:7/10/2017 3:44 PM Machine Setup Details Machine Setup Name : CLG H2O 1 UNIT3 Setup Field Input Motor type AC AC motor with VFD

Page10

Date:7/10/2017 3:44 PMLocation : Location 3Range : High rangeAxis : RadialX Axis Unit : OrdersY Axis Unit : mm/sec1X RPM : 1780 RPM

Location : Location 3Range : Low rangeAxis : RadialX Axis Unit : OrdersY Axis Unit : mm/sec1X RPM : 1780 RPM

Page 10: Unit 3 Pump #1 07-10-17 - Maintenance · Page16 Date:7/10/2017 3:44 PM Machine Setup Details Machine Setup Name : CLG H2O 1 UNIT3 Setup Field Input Motor type AC AC motor with VFD

Page11

Date:7/10/2017 3:44 PMLocation : Location 4Range : High rangeAxis : AxialX Axis Unit : OrdersY Axis Unit : mm/sec1X RPM : 1780 RPM

Location : Location 4Range : Low rangeAxis : AxialX Axis Unit : OrdersY Axis Unit : mm/sec1X RPM : 1780 RPM

Page 11: Unit 3 Pump #1 07-10-17 - Maintenance · Page16 Date:7/10/2017 3:44 PM Machine Setup Details Machine Setup Name : CLG H2O 1 UNIT3 Setup Field Input Motor type AC AC motor with VFD

Page12

Date:7/10/2017 3:44 PMLocation : Location 4Range : High rangeAxis : TangentialX Axis Unit : OrdersY Axis Unit : mm/sec1X RPM : 1780 RPM

Location : Location 4Range : Low rangeAxis : TangentialX Axis Unit : OrdersY Axis Unit : mm/sec1X RPM : 1780 RPM

Page 12: Unit 3 Pump #1 07-10-17 - Maintenance · Page16 Date:7/10/2017 3:44 PM Machine Setup Details Machine Setup Name : CLG H2O 1 UNIT3 Setup Field Input Motor type AC AC motor with VFD

Page13

Date:7/10/2017 3:44 PMLocation : Location 4Range : High rangeAxis : RadialX Axis Unit : OrdersY Axis Unit : mm/sec1X RPM : 1782 RPM

Location : Location 4Range : Low rangeAxis : RadialX Axis Unit : OrdersY Axis Unit : mm/sec1X RPM : 1780 RPM

Page 13: Unit 3 Pump #1 07-10-17 - Maintenance · Page16 Date:7/10/2017 3:44 PM Machine Setup Details Machine Setup Name : CLG H2O 1 UNIT3 Setup Field Input Motor type AC AC motor with VFD

Page14

Date:7/10/2017 3:44 PM

Fault description : Motor Drive End Bearing Wear

Fault severity : Moderate (43)

Cited peak number Bearing Axis Vibration amplitude Order Range

Cited peak1 Location2 Radial 1.60 mm/sec 70.2 High

Cited peak2 Location2 Radial 0.47 mm/sec 62.1 High

Cited peak3 Location2 Axial 0.41 mm/sec 5.88 Low

Cited peak4 Location2 Axial 0.34 mm/sec 69.4 High

Cited peak5 Location2 Radial 0.27 mm/sec 5.88 Low

Cited peak6 Location2 Tangential 0.26 mm/sec 70 High

Cited peak7 Location2 Axial 0.19 mm/sec 4.89 Low

Cited peak8 Location2 Radial 0.16 mm/sec 4.89 Low

Cited peak9 Location2 Axial 0.14 mm/sec 37.4 High

Cited peak10 Location2 Tangential 0.12 mm/sec 6.88 Low

Page 14: Unit 3 Pump #1 07-10-17 - Maintenance · Page16 Date:7/10/2017 3:44 PM Machine Setup Details Machine Setup Name : CLG H2O 1 UNIT3 Setup Field Input Motor type AC AC motor with VFD

Page15

Date:7/10/2017 3:44 PM

Fault description : Pump Free End Ball Bearing Wear

Fault severity : Slight (22)

Cited peak number Bearing Axis Vibration amplitude Order Range

Cited peak1 Location4 Axial 0.75 mm/sec 11.3 High

Cited peak2 Location4 Tangential 0.50 mm/sec 11.3 High

Cited peak3 Location4 Axial 0.28 mm/sec 10.3 Low

Cited peak4 Location4 Radial 0.24 mm/sec 11.3 High

Cited peak5 Location4 Axial 0.21 mm/sec 10.6 Low

Cited peak6 Location4 Tangential 0.17 mm/sec 10.3 Low

Page 15: Unit 3 Pump #1 07-10-17 - Maintenance · Page16 Date:7/10/2017 3:44 PM Machine Setup Details Machine Setup Name : CLG H2O 1 UNIT3 Setup Field Input Motor type AC AC motor with VFD

Page16

Date:7/10/2017 3:44 PM

Machine Setup Details

Machine Setup Name : CLG H2O 1 UNIT3

Setup Field Input

Motor type AC

AC motor with VFD No

Speed in RPM 1780

Nominal kw 0

Motor mounted Horizontal

Motor has Roller bearing

Motor detached from drive train No

Motor close-coupled No

Coupling between motor and next component Yes

Next component Pump

Driven component bearing type Roller bearing

Pump type Centrifugal

Impeller is supported by Overhung

No. of pump vanes or blades [optional]