under / over voltage relay trainer under / over...
TRANSCRIPT
UNDER / OVER VOLTAGE RELAY TRAINER (Model : XPO-PRT/UOV)
SALIENT FEATURESu
u
u
u
u
u
Each of above trainer has built in requisite relay testing kit typically consisting of voltage injector, current injector, elapsed time counter (1 msec. resolution), trip relay logic etc.
Useful for Post Graduate projects and research purpose.
The Trainer need a few set of associated relay testing (current / voltage injection etc. ) panels (7-8 nos. typically) which are mounted in a light weight sturdy aluminum profile flat demo panel system. Do not need any separate testing kit.
Facilitates easy and safe wiring by students due to use of 4mm sturdy Shrouded banana patch cords and shrouded socket arrange-ments for high voltage circuits
Each panel has ABS molded plastic sturdy enclosure, and colorful screwless overlays showing circuits diagrams & its connection tag numbers for easy understanding and connection
Set of Instructor Guide & Student Workbook
Technical Specifications
u Input 3 phase DOL Starter panel (EMT1)
u Integrated AC 3 phase measurement panel
(EMT 34)
u Under / Over / Under / Unbalance Voltage Relay
Panel (EMT51)
l 4 pole MCB of 415 V/4A .
l DOL 9A Contactor with 230V / 50 Hz / 11VA COIL .
l Bimetallic thermal O/L relay with range
2.5A -6A .
l Consist of (96 X 96 mm) Digital meters for 3 ph.
l Measures V, I, PF (0.2 lag – unity 0.2 lead), Hz.
Hence separate analog wattmeters (3ph., 1ph.)
are not needed.
l All the connection of relay are brought out on this
panel.
l 1 NO and 1 NC contact
l Relay Coil
u FWD-OFF-REV Switch Panel (EMT 4A)
u Over current & elapsed time measurement
panel (EMT 39)
u Mechanical Dimension(mm)/Weight:
l FWD/REV, 3 pole 3 way switch with center OFF, 6A/440V.
l Consists of AC ammeter of 20A
l Elapsed time counter range 999.001 sec, resolution 1 msec.
l Electromechanical or Numerical Type IDMT Under / Over Voltage Relay.
1) To Plot characteristics of under voltage relay.
2) To Plot characteristics of over voltage relay.
3) Reverse phasing protection
4) Unbalanced voltage protection
3 Phase 3 Amp. Variac.
1170 (L) x 300(W) x 545(H)l Net Wt. = 20 Kg. Gross Wt. = 31 kg.
Protection Relay Type [EM/Static/Num]
List of Experiments
Accessories :
OPTIONAL
Over/Under Voltage RelayElectromechanical
92
Switc
hgea
r & P
rote
ction
Lab
93
Switc
hgea
r & P
rote
ction
Lab
UNDER / OVER FREQUENCY RELAY TRAINER (Model : XPO-PRT/UOF)
SALIENT FEATURESu
u
u
u
u
u
Each of above trainer has built in requisite relay testing kit typically consisting of voltage injector, current injector, elapsed time counter (1 msec. resolution), trip relay logic etc.
The Trainer need a few set of associated relay testing (current / voltage injection etc. ) panels (7-8 nos. typically) which are mounted in a light weight sturdy aluminum profile flat demo panel system. Do not need any separate testing kit.
Facilitates easy and safe wiring by students due to use of 4mm sturdy Shrouded banana patch cords and shrouded socket arrange-ments for high voltage circuits
Each panel has ABS molded plastic sturdy enclosure, and colorful screwless overlays showing circuits diagrams & its connection tag numbers for easy understanding and connection
Useful for Post Graduate Project & Research Purpose
Set of Instructor Guide & Student Workbook
Technical Specifications
u Input 3 phase DOL Starter panel (EMT1)
u Integrated AC 3 phase measurement panel (EMT
34)
u Under / Over Frequency Relay Panel (EMT67)
u 415/110VAC, Star/Star Step Down Transformer
Panel (EMT54)
l 4 pole MCB of 415 V/4A .
l DOL 9A Contactor with 230V / 50 Hz / 11VA COIL .
l Bimetallic thermal O/L relay with range
2.5A -6A .
l Consist of (96 X 96 mm) Digital meters for 3 ph.
l Measures V, I, PF (0.2 lag – unity 0.2 lead), Hz. Hence separate analog wattmeters (3ph., 1ph.) are not needed.
l All the connection of relay are brought out on this panel.
l 1 NO and 1 NC contact
l Relay Coil
l This panel consisting of 415/110VAC, 50VA, Star / Star Step Down Transformer Panel
l All the connections of transformer primary and secondary are brought on SBS5 on the top of panel
l Consists of AC ammeter of 20A
l Elapsed time counter range 999.001 sec, resolution 1 msec.
Microprocessor / Microcontroller Based. Able to communicate with PC.
1) To study the operation of over frequency protection
relay.
2) To study the operation of under frequency protection
relay.
1170 (L) x 300(w) x 545 (H)
l Net Weight : 20 kg. Gross Weight : 31 kg.
u Over current & elapsed time measurement panel
(EMT 39)
u Mechanical Dimension (mm) / Weight of Trainer :
Protection Relay Type:
List of Experiments