um 1.01 30x42 - nocccd.edu

2
THE SEAL AND SIGNATURE APPLY ONLY TO THE DOCUMENT TO WHICH THEY ARE AFFIXED. THE SIGNER OF THIS DOCUMENT EXPRESSLY DISCLAIMS ANY AND ALL RESPONSIBILITY FOR DOCUMENTS THAT DO NOT BEAR HIS SEAL AND SIGNATURE INCLUDING, BUT NOT NECESSARILY LIMITED TO, DRAWINGS, SPECIFICATIONS, ESTIMATES, REPORTS AND OTHER SIMILAR INSTRUMENTS OF SERVICES INTENDED TO BE USED FOR THIS PROJECT. MAPPING NO. CHECKED BY DRAWN BY SHEET SHEET TITLE DRAWING ISSUE DATE DATE SIGNATURE PARCEL NO. MSD BASE MAP PROJECT NO. NO. DATE NO. DATE NO. DATE NO. DATE NO. ZIP CODE PREPARED FOR: DATE NO. DATE NO. DATE NO. PREPARED BY: DATE NO. DATE NO. DATE NO. DATE NO. DATE NO. DATE NO. DATE NO. DATE NO. DATE NO. DATE NO. . CLM MAP20NPB.C05 . . . LOCATOR MAP NOT TO SCALE SITE DRAWING INDEX FULLERTON COMMUNITY COLLEGE 321 E. CHAPMAN AVE., FULLERTON, CA 92832 EXISTING SUBSURFACE UTILITY EXHIBIT MAPPING NUMBER: MAP20NPB.C05 PROJECT DIRECTORY UM 1.00 COVER SHEET . UTILITY COMPANY CONFLICT STATEMENT: Upon completion of the Existing Subsurface Utility Exhibit, the following utility companies will be provided with copies for review: The aforementioned utility companies will have thirty (30) days to review the information and comment on any potential conflicts. If no comments or correspondence is received by these utility companies, we will assume there are no conflicts with the utility locations shown on this Existing Subsurface Utility Exhibit and issue the drawing. ELECTRIC SOUTHERN CALIFORNIA EDISON PO BOX 800 ROSEMEAD, CA 91770 800-655-4555 GAS SOUTHERN CALIFORNIA GAS PO BOX C MONTEREY PARK, CA 91756 800-427-2000 TELEPHONE AT&T TELELPHONE CO. CUSTOMER SERVICE LINE 800-288-2020 MCI/VERIZON CUSTOMER SERVICE LINE 888-624-5622 CABLE TV SPECTRUM CUSTOMER SERVICE LINE 833-267-6094 WATER CITY OF FULLERTON PUBLIC WORKS 1580 W. COMMONWEALTH AVE - CITY YARD FULLERTON,CA 92833 714-738-6897 STORM & SANITARY SEWER CITY OF FULLERTON PUBLIC WORKS 1580 W. COMMONWEALTH AVE - CITY YARD FULLERTON,CA 92833 714-738-6897 FIBER OPTIC LEVEL 3 COMMUNICATIONS CUSTOMER SERVICE LINE 877-253-8553 FIBER OPTIC CROWN CASTLE CUSTOMER SERVICE LINE 855-935-4237 FULLERTON, CA ORANGE COUNTY 321 E. CHAPMAN AVE. C McCarthy Building Companies, Inc. 2020 GENERAL NOTES: UM 1.00 UTILITY QUALITY LEVEL INFORMATION INDEX: QUALITY LEVEL D: “QL D”: Records Search: This level of service provides information that has been obtained from existing records, which includes utilizing existing plans, contacting utility companies, verbal recollections, obtaining as-built plans and researching prior rights (i.e. easements) issues. QUALITY LEVEL C: “QL C”: This level adds field surveys of visible above-ground utility systems such as maintenance holes, valve boxes, fire hydrants, etc., and reconciles this information to existing utility records (Quality Level D) QUALITY LEVEL B: “QL B”: Designating Underground Utility Systems: This level includes using surface geophysical prospecting techniques, including electromagnetic, magnetic, sonic, or other energy fields to determine the existence, horizontal position of underground utility systems. approximate vertical positions of subsurface utilities can be identified depending on the specific subsurface prospecting technique utilized. QUALITY LEVEL A: “QL A”: Locating Underground Utility Systems: This level is the highest level of accuracy, which includes obtaining precise horizontal and vertical position of the utility line by excavating a test hole. The test holes shall be done using vacuum excavation or comparable nondestructive equipment in a manner as to cause no damage to the utility line. After excavating a test hole, a field survey was performed to determine the exact location and position of the utility line, type, size, condition, material, and other characteristics of underground utility system. TYPICAL UTILITY CALLOUT: UTILITY TYPE UTILITY MATERIAL TYPE UTILITY SIZE QUALITY LEVEL TYPICAL SHEET CALLOUT: SHEET ORDER SHEET TYPE DISCIPLINE SHEET # SHEET NAME UM 1.00 UM 1.01 COVER SHEET EXISTING COMPOSITE UTILITY PLAN - QL-B 1. This plan was prepared in conformance with ASCE standard CI/ASCE 38-02 “American Society of Civil Engineers Standard Guideline for the Collection and Depiction of Existing Subsurface Utility Data”. 2. WE will only warrant the three dimensional location of utility lines based on quality level A information. QL “A” information is only valid within the visible limits of the test hole. 3. WE will advance a vacuum test hole until a condition of practical refusal for vacuum excavation is reached. Practical refusal is defined as any of the following conditions occurring: bedrock, water table or reaching a depth of 12'. 4. Below ground structures, unless dimensioned, are symbolic only. 5. Prior to excavation utility owners shall review and approve this drawing. 6. This drawing is prepared in color. Reproduction may alter the information contained herein. WE do not warrant the information contained herein in the event of reproduction. 7. Base mapping/survey control is shown for information only and is not warranted. 8. WE recommend that all existing utilities critical to proposed construction activities be located by vacuum excavation (quality level A) prior to any excavation (if not already located by vacuum excavation). 9. Utility Lines shown on the plans labeled as Quality Level B have been traced and surveyed using various geophysical instruments. Unless noted as Quality Level B it should be assumed that lines are shown as approximate only. 10. Utility Lines depicted on the plan as ASCE Quality Level D are from various plans and records from public or private stakeholders. WE requested that all available plans and records be provided from all of the known stakeholders. 11. WE obtained numerous One Call design tickets for this project and the locations of all markouts have been surveyed and documented. 12. Electrical lines shown on the plans were traced using hand held locators by indirect induction methods. The lines traced are depicted as ASCE 38-02 Quality Level B. 13. Telephone and communication lines shown on the plans were traced using direct and indirect connections through building basements, vaults, and hand holes. The lines traced are depicted as ASCE 38-02 Quality Level B. 14. Water lines were traced using direct and indirect induction methods. The lines traced are depicted as ASCE 38-02 Quality Level B. 15. Underground structural elements such as tie backs, sheeting, shoring, framing, piles or pile caps have not been plotted within this set. The respective public and private plans should be reviewed prior to demolition and construction in order to identify underground structural elements. 16. Utilities located within fenced in electrical sub-stations are not accessible by field personnel, therefore can not be field located. 17. Utility vault structures are shown using best available information collected at the time of the survey/investigation. However, data may be limited by accessibility and measurement accuracies. All below grade utility vaults structures shown hereon should be considered approximate and are depicted as ASCE 38-02 Quality Level C. 18. (**) Denotes a portion of utility alignment that has been located via alternate geophysical locating methods (acoustic pipe locator and/or ground penetrating radar). When design or construction is affected by the portrayed location of this alignment, additional potholing investigation is recommended. 19. Any and all depth of utilities depicted at a QL-B standard of care hereon shall be considered approximate as of the date of the investigation and shall not be used as a basis of design, constructability analysis, or construction methodology without further investigation to expose the utility in question and obtain a hard measurement. It is the responsibility of the contractor to utilize soft digging best practices to expose all utilities having a potential for conflict within the area of excavation prior to any hard digging excavation. McCarthy shall not be held liable for any decisions of incidents that result from the reliance upon any of the QL-B provided depth information. PROJECT MANAGER CONTACT McCARTHY MAPPING Andy Wittmann CELL: 970-302-0675 WEBSITE: http://www.mapping.mccarthy.com Email: [email protected] LEGEND: 20401 SW Birch St. Newport Beach, California 92660 p: 949-851-8383 http://www.mccarthy.com McCARTHY MAPPING - SOCAL Know what's below. before you dig. Call R FULLERTON COMMUNITY COLLEGE 321 E. Chapman Ave. Fullerton, CA 92832 714-992-7000

Upload: others

Post on 27-Jan-2022

7 views

Category:

Documents


0 download

TRANSCRIPT

THE SEAL AND SIGNATURE APPLY ONLY TO THE DOCUMENT TO WHICHTHEY ARE AFFIXED. THE SIGNER OF THIS DOCUMENT EXPRESSLYDISCLAIMS ANY AND ALL RESPONSIBILITY FOR DOCUMENTS THAT DONOT BEAR HIS SEAL AND SIGNATURE INCLUDING, BUT NOT NECESSARILYLIMITED TO, DRAWINGS, SPECIFICATIONS, ESTIMATES, REPORTS ANDOTHER SIMILAR INSTRUMENTS OF SERVICES INTENDED TO BE USED FORTHIS PROJECT.

MAPPING NO.

CHECKED BY

DRAWN BY

SHEET

SHEET TITLE

DRAWING ISSUE

DATE

DATE

SIGNATURE

PARCEL NO.

MSD BASE MAP

PROJECT NO.

NO.

DATENO.

DATENO.

DATENO.

DATENO.

ZIP CODE

PREPARED FOR:

DATENO.

DATENO.

DATENO.

PREPARED BY:

DATENO.

DATENO.

DATENO.

DATENO.

DATENO.

DATENO.

DATENO.

DATENO.

DATENO.

DATENO.

.

CLMMAP20NPB.C05

.

.

.

LOCATOR MAPNOT TO SCALE

SITE

DRAWING INDEX

FULLERTON COMMUNITY COLLEGE

321 E. CHAPMAN AVE., FULLERTON, CA 92832

EXISTING SUBSURFACE UTILITY EXHIBIT

MAPPING NUMBER:

MAP20NPB.C05

PROJECT DIRECTORY

UM 1.00

COVERSHEET

.

UTILITY COMPANY CONFLICT STATEMENT:Upon completion of the Existing Subsurface Utility Exhibit, the following utilitycompanies will be provided with copies for review:

The aforementioned utility companies will have thirty (30) days to review theinformation and comment on any potential conflicts. If no comments or correspondenceis received by these utility companies, we will assume there are no conflicts with theutility locations shown on this Existing Subsurface Utility Exhibit and issue the drawing.

ELECTRICSOUTHERN CALIFORNIA EDISONPO BOX 800ROSEMEAD, CA 91770800-655-4555

GASSOUTHERN CALIFORNIA GASPO BOX CMONTEREY PARK, CA 91756800-427-2000

TELEPHONEAT&T TELELPHONE CO.CUSTOMER SERVICE LINE800-288-2020

MCI/VERIZONCUSTOMER SERVICE LINE888-624-5622

CABLE TVSPECTRUMCUSTOMER SERVICE LINE833-267-6094

WATERCITY OF FULLERTON PUBLIC WORKS1580 W. COMMONWEALTH AVE - CITY YARDFULLERTON,CA 92833714-738-6897

STORM & SANITARY SEWERCITY OF FULLERTON PUBLIC WORKS1580 W. COMMONWEALTH AVE - CITY YARDFULLERTON,CA 92833714-738-6897

FIBER OPTICLEVEL 3 COMMUNICATIONSCUSTOMER SERVICE LINE877-253-8553

FIBER OPTICCROWN CASTLECUSTOMER SERVICE LINE855-935-4237

FULLERTON, CA ORANGE COUNTY

321E. CHAPMAN AVE.

C McCarthy Building Companies, Inc. 2020

GENERAL NOTES:

UM 1.00

UTILITY QUALITY LEVEL INFORMATION INDEX:QUALITY LEVEL D: “QL D”: Records Search: This level of service provides information that has been obtained from existingrecords, which includes utilizing existing plans, contacting utility companies, verbal recollections, obtaining as-built plansand researching prior rights (i.e. easements) issues.

QUALITY LEVEL C: “QL C”: This level adds field surveys of visible above-ground utility systems such as maintenance holes,valve boxes, fire hydrants, etc., and reconciles this information to existing utility records (Quality Level D)

QUALITY LEVEL B: “QL B”: Designating Underground Utility Systems: This level includes using surface geophysicalprospecting techniques, including electromagnetic, magnetic, sonic, or other energy fields to determine the existence,horizontal position of underground utility systems. approximate vertical positions of subsurface utilities can be identifieddepending on the specific subsurface prospecting technique utilized.

QUALITY LEVEL A: “QL A”: Locating Underground Utility Systems: This level is the highest level of accuracy, which includesobtaining precise horizontal and vertical position of the utility line by excavating a test hole. The test holes shall be doneusing vacuum excavation or comparable nondestructive equipment in a manner as to cause no damage to the utilityline. After excavating a test hole, a field survey was performed to determine the exact location and position of theutility line, type, size, condition, material, and other characteristics of underground utility system.

TYPICAL UTILITY CALLOUT:

UTILITY TYPE

UTILITY MATERIAL TYPE

UTILITY SIZE

QUALITY LEVEL

TYPICAL SHEET CALLOUT:

SHEET ORDER

SHEET TYPE

DISCIPLINE

SHEET #

SHEET NAME

UM 1.00

UM 1.01

COVER SHEET

EXISTING COMPOSITE UTILITY PLAN - QL-B1. This plan was prepared in conformance with ASCE standard CI/ASCE 38-02 “American Society of Civil EngineersStandard Guideline for the Collection and Depiction of Existing Subsurface Utility Data”.

2. WE will only warrant the three dimensional location of utility lines based on quality level A information. QL “A”information is only valid within the visible limits of the test hole.

3. WE will advance a vacuum test hole until a condition of practical refusal for vacuum excavation is reached.Practical refusal is defined as any of the following conditions occurring: bedrock, water table or reaching adepth of 12'.

4. Below ground structures, unless dimensioned, are symbolic only.

5. Prior to excavation utility owners shall review and approve this drawing.

6. This drawing is prepared in color. Reproduction may alter the information contained herein. WE do not warrantthe information contained herein in the event of reproduction.

7. Base mapping/survey control is shown for information only and is not warranted.

8. WE recommend that all existing utilities critical to proposed construction activities be located by vacuumexcavation (quality level A) prior to any excavation (if not already located by vacuum excavation).

9. Utility Lines shown on the plans labeled as Quality Level B have been traced and surveyed using variousgeophysical instruments. Unless noted as Quality Level B it should be assumed that lines are shown asapproximate only.

10. Utility Lines depicted on the plan as ASCE Quality Level D are from various plans and records from public or privatestakeholders. WE requested that all available plans and records be provided from all of the known stakeholders.

11. WE obtained numerous One Call design tickets for this project and the locations of all markouts have beensurveyed and documented.

12. Electrical lines shown on the plans were traced using hand held locators by indirect induction methods. The linestraced are depicted as ASCE 38-02 Quality Level B.

13. Telephone and communication lines shown on the plans were traced using direct and indirect connectionsthrough building basements, vaults, and hand holes. The lines traced are depicted as ASCE 38-02 Quality Level B.

14. Water lines were traced using direct and indirect induction methods. The lines traced are depicted as ASCE 38-02Quality Level B.

15. Underground structural elements such as tie backs, sheeting, shoring, framing, piles or pile caps have not beenplotted within this set. The respective public and private plans should be reviewed prior to demolition andconstruction in order to identify underground structural elements.

16. Utilities located within fenced in electrical sub-stations are not accessible by field personnel, therefore can not befield located.

17. Utility vault structures are shown using best available information collected at the time of thesurvey/investigation. However, data may be limited by accessibility and measurement accuracies. All below gradeutility vaults structures shown hereon should be considered approximate and are depicted as ASCE 38-02 QualityLevel C.

18. (**) Denotes a portion of utility alignment that has been located via alternate geophysical locating methods(acoustic pipe locator and/or ground penetrating radar). When design or construction is affected by the portrayedlocation of this alignment, additional potholing investigation is recommended.

19. Any and all depth of utilities depicted at a QL-B standard of care hereon shall be considered approximate as of thedate of the investigation and shall not be used as a basis of design, constructability analysis, or constructionmethodology without further investigation to expose the utility in question and obtain a hard measurement. It isthe responsibility of the contractor to utilize soft digging best practices to expose all utilities having a potential forconflict within the area of excavation prior to any hard digging excavation. McCarthy shall not be held liable forany decisions of incidents that result from the reliance upon any of the QL-B provided depth information.

PROJECT MANAGER CONTACT

McCARTHY MAPPING

Andy Wittmann

CELL: 970-302-0675

WEBSITE: http://www.mapping.mccarthy.com

Email: [email protected]

LEGEND:

20401 SW Birch St.Newport Beach, California 92660

p: 949-851-8383http://www.mccarthy.com

McCARTHY MAPPING - SOCAL

Know what'sbelow.before you dig.CallR

FULLERTON COMMUNITY COLLEGE321 E. Chapman Ave.Fullerton, CA 92832714-992-7000

ASPH

ASPH

ASPH

ASPH

170

X

X

X

X

XX

X

XX

XX

X

XX

XX

XX

XX

X

PRO

JEC

T LI

MITS

PRO

JEC

T LI

MITS

PRO

JEC

T LI

MITS

PROJECT LIMITS

PROJECT LIMITS

PROJECT LIMITSPROJECT LIMITS

PROJECT LIMITS

PRO

JEC

T LI

MITS

PRO

JEC

T LI

MITS

THE SEAL AND SIGNATURE APPLY ONLY TO THE DOCUMENT TO WHICHTHEY ARE AFFIXED. THE SIGNER OF THIS DOCUMENT EXPRESSLYDISCLAIMS ANY AND ALL RESPONSIBILITY FOR DOCUMENTS THAT DONOT BEAR HIS SEAL AND SIGNATURE INCLUDING, BUT NOT NECESSARILYLIMITED TO, DRAWINGS, SPECIFICATIONS, ESTIMATES, REPORTS ANDOTHER SIMILAR INSTRUMENTS OF SERVICES INTENDED TO BE USED FORTHIS PROJECT.

CHECKED BY

DRAWN BY

SHEET

SHEET TITLE

DRAWING ISSUE

DATE

DATE

SIGNATURE

MSD BASE MAP

NO.

DATENO.

DATENO.

DATENO.

DATENO.

ZIP CODE

PREPARED FOR:

DATENO.

DATENO.

DATENO.

PREPARED BY:

DATENO.

DATENO.

DATENO.

DATENO.

DATENO.

DATENO.

DATENO.

DATENO.

DATENO.

DATENO.

.

CLM.

.

.

.

.

EXISTING COMPOSITEUTILITY PLAN - QL-B

UM 1.01EXISTING - COMPOSITE UTILITY PLAN

GRAPHIC SCALE 1"=20'

0 20 40

PARCEL NO.

MAPPING NO.

PROJECT NO.

C McCarthy Building Companies, Inc. 2020

NOTE: ANY AND ALL DEPTH OF UTILITY'S DEPICTED AT A QL-B STANDARD OF CARE HEREON SHALL BECONSIDERED APPROXIMATE AS OF THE DATE OF THE INVESTIGATION. IT IS THE RESPONSIBILITY OF THECONTRACTOR TO UTILIZE SOFT DIGGING BEST PRACTICES TO EXPOSE ALL UTILITIES HAVING A POTENTIALFOR CONFLICT WITHIN THE AREA OF EXCAVATION PRIOR TO ANY HARD DIGGING EXCAVATION.

MAP20NPB.C05

FULLERTON, CA ORANGE COUNTY

321E. CHAPMAN AVE.

20401 SW Birch St.Newport Beach, California 92660

p: 949-851-8383http://www.mccarthy.com

McCARTHY MAPPING - SOCAL