ultrasound and arthropod pest control: hearing is believing! · sound pressure level (db re 20...

103
Ultrasound and Arthropod Pest Control: Hearing is Believing! Bhadriraju Subramanyam (Subi) Department of Grain Science and Industry Kansas State University Manhattan, KS 66506 [email protected]

Upload: others

Post on 26-Jun-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Ultrasound and Arthropod Pest Control: Hearing is Believing!

Bhadriraju Subramanyam (Subi)Department of Grain Science and Industry

Kansas State UniversityManhattan, KS 66506

[email protected]

Page 2: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

• Introduction

• Summary of published data: efficacy tests

• Results from tests on household pests

• Results from tests on Indian meal moth (Storage pest)

• Overall conclusions

• Future research needs

Seminar outline

Page 3: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Sound sensitivity in different animals (From Dusenbery, 1992)

0.02 0.05 0.1 0.2 0.5 1 2 5 10 20 50 100

344 34.4 3.44 0.344

Man

Bats

RodentsWhales and dolphins

Seals and sea lions

Birds

FrogsFish

Moths

Bush crickets

Crickets

Grasshoppers

Wavelength, cm

Frequency, kHzInfrasound Ultrasound

Page 4: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Insects use specialized organsInsects use specialized organs

• For remote sensing potential predators, prey, mates, or rivals

• To see – eyes• To hear – auditory organs• To smell – olfactory organs• Feel presence of others – proprioreceptors

and cuticular hairs

Page 5: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

• An acoustic signal is generated by vibrations of a sound-producing organ

• Mechanoreceptive organs perceive the sound

Page 6: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

• Near-field acoustic detectors– Cerci of cockroaches, Johnston’s organs of mosquitoes,

aristae of drosophilid flies– Lack eardrums– Work short distances (few body lengths in drosophilid

flies, 1 m for male mosquitoes)– Low frequencies, 75 – 500 Hz

• Far-field acoustic detectors– Respond to 2 – 100 kHz– Can detect sounds from long distances (10 m or more)– Need tympanic organs or eardrums (but not always)– Thin region of cuticle with an air-filled sac behind it

and a chordotonal sensory organ

Page 7: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Tympanal hearing• Present in 7 insect orders• Neuroptera – wing base• Lepidoptera – Abdomen, metathorax, base of fore or

hind wing• Coleoptera – Cervical membranes, abdomen• Dictyoptera – Ventral metathorax, Metathoracic leg• Orthoptera – First abdominal segment, prothoracic leg• Hemiptera – Abdomen, mesothorax• Diptera – Ventral pro-sternum

Page 8: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Indian meal moth

Tympanic organ of Indian meal moth (Mullen & Tsao 1971)

a: Anterior view of the tympanic organ

c: Division between tympanic membrane proper and countertympanicmembrane.

b. Anterior view of the left tympanic organ

d. Area of external expression of Muller’s organ

Page 9: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Insects use ultrasound for several purposes• Long-distance mate calling (male calls, female responds--in crickets, katydids, grasshoppers, and cicadas)

• Short distance calling song (by mutual antennation in field crickets)

• Rivarly song or territorial proclamation (male-male aggression)

• Predator detection – night flying moths

• Acoustic parasitism – Field crickets and tachinid fly (Ormea ochracea), 4 – 6 kHz (host 4.8 kHz). Fly also is sensitive to 20 –60 kHz sound

• Male and female insects have different auditory sensitivities (Gypsy moth, tachinid flies, cicadas)

• Intra-specific communication vs prey detection

Page 10: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Auditory capabilities evolved

• To facilitate conspecific communication• To detect predators __________________________________________• Insect’s ability to hear need not be based solely on

organs visible on anatomic examination of the body surface

• Only a few species have been studied • Species that use auditory signals may do it at night

or high in the air—a challenge for us to study!

Page 11: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Echolocating bats• Aerial hawking bats

– Catch flying insects on the wing– Use sonar to target and capture prey– Prefer open habitats– Produce low frequency, high intensity, long duration

pulses• Substrate gleaning bats

– Forage near the ground or surrounding vegetation– Use sonar as a navigational tool to avoid obstacles– Prefer “closed” habitats– Produce high frequency, low intensity, short duration

pulses– Acoustically less “conspicuous” to eared insects

Page 12: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

• Left: The tracks of a gypsy moth male flying in the wind tunnel in response to pheromone emanating from the pheromone disperser. No auditory stimulus was given.

• Right: The tracks of a pheromone responding male in the wind tunnel when the auditory stimulus was given (arrow) from outside the wind tunnel causing the male to abruptly change course and fly out of the plume (Baker & Cardé 1978)

Evasive maneuvers by Gypsy moth males

Page 13: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Ultrasonic devices and pest control

Page 14: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

United States ultrasound market

• More than 60 manufacturers and retailers

• Estimated market value may be around 100 million• One US company alone has $20 million in sales

annually

Page 15: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Range of available ultrasonic devices marketed in the United States

Page 16: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Target pests

Rats, mice, squirrels, mosquitoes, ants, spiders, cockroaches, flies, fleas, ticks, crickets, yellow jackets, bees, moths,

water bugs, silverfish …

Manufacturers and retailers claim that pests can be repelled by ultrasonic devices!

Page 17: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

• Gets rid of household pests without chemicals or poisons

• Our safe Electronic Pest Repellers and Flea Collars use high frequency sound to drive away pests

• Millions of satisfied users report that these products safely chase away fleas, mice, rats, squirrels and other rodents, as well as roaches, moths, ants, spiders, mosquitoes, and many other creepy pests

Source: http://www.hitecpet.com/pestcontrol.html

Preposterous claims by manufacturers and retailers

Page 18: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

The DX-610 electronic pest control repeller• Drives away mice and rats, fleas, spiders, bats, ants, cockroaches, moths, water bugs, silverfish, and most other common pests

• Covers 2,000-2,500 square feet

• Environments: Homes, but also in their garages, offices, warehouses, campers, restaurants, schools, and barns

• Marketing: Over 23 countries, including Japan, Australia, Greece, Spain, Brazil, Denmark, Mexico, and Canada

Testimonials

"...could hear the mice running around at night. Well, now they are gone. This product really worked!” ---- Bob G. from Massachusetts

"...I can't believe how good it works. FIRST CLASS PRODUCT!" … Joe J from Nevada

• Source: http://www.msglobaldirect.com/html/electronic_pest_control.html

Page 19: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Published research results

Most tests measured repellent effects

Page 20: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Field and laboratory efficacy tests with ultrasonic devices

Pests Authors Test conditions Frequency,kHz

SPL dB at distance, cm

Effective S/F

Brown & Lewis, 1991

Dryden et. al.,1989

Dryden & Gaafar, 1991

Dryden et al. 2000

Hinkle & Koehler, 1990

Koehler et al., 1989

Schein et al., 1988 Lab -- -- no 0/1

Rust & Parker, 1988

Lab 1 – 20040, 50

-- no 0/1

Koehler et al., 1986

Chamber -- -- no

Summary of successes (S)/failures (F): 0/21

Cage 40 80-92 at 100 no

0/4

0/2

0/1

0/1

0/1

0/1

Cage 40-50 -- no

Cage -- -- no

Cage 35, 39, 41 102 at 584 at 50

no

Lab 40 82 at 5076 at 100

no

0/9Room Chamber 17 - 61 51 – 103 at 100 no

Flea

Page 21: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Pests Authors Test conditions Frequency,kHz

SPL dB at distance, cm

Effective S/F

Brown & Lewis, 1991

Ballard & Gold, 1983

Ballard et al., 1984

Gold et al., 1984

Koehler et al., 1986

Koehler et al., 1989

Schreck et al., 1984 Chamber 1: 44, 532: 30-35, 43

1: 65 at 502: 96 at 0.5

no 0/2

Brown & Lewis, 1991 Chamber -- -- no 0/4

Schein et al., 1988 Lab -- -- no 0/1

Tick

Summary of the successes (S)/failures (F): 13/42

Chamber -- -- no

Summary of the successes (S)/failures (F): 0/5

Chamber 20-60 -- ?

0/4

6/18

4/4

3/4

0/9

Chamber 30-65 60-68.5 at 200 yes

Chamber 40, 20-50 70-110 at 91 ?

Room Chamber 17 - 61 51 – 103 at 100 no

Lab 40 82 at 5076 at 100

no 0/1

Cockroach

Page 22: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Pests Authors Test conditions FrequencykHz

SPL dB at distance cm

Effective Ratio

Gorham, 1974

Kutz, 1974

Mosquito

Garcia et al., 1976 Lab and field -- -- no 0/1

Schreck et al., 1984 Chamber 1: 44, 532: 30-35, 43

1: 65 at 502: 96 at 0.5

no 0/2

Schreiber et al., 1991 Chamber and field - - no 0/5

Sylla et al., 2000 Houses 3-11 -- no 0/4

Summary of the successes (S)/failures (F): 0/14

Belton & Kempster, 1962

Corn field 50 100 at 30 yes 1/1, 50% RdEuropean corn borer

Agee & Webb, 1969 Light traps 20, 25, 30 100 at 100 yes 1/1, Rd by 81%

Cabbage looper

Payne & Shorey, 1968

Lettuce and broccoli fields

20, 30 40 --- yes 2/3, Rd up to 66%

Agee & Webb, 1969 Cotton field 20, 25, 30 100 at 100 no 0/1

Shorey et al., 1972 Corn field 20 60-105 at 25,00-0 no 0/1

Agee & Webb, 1969 Light traps 20, 25, 30 100 at 100 yes 1/1 Rd by 75%

Summary of the successes (S)/failures (F): Moth= 5/8; Overall=18/90

-- -- -- no

Bollworm

-- -- -- no

0/1

0/1

Mosquito

Some field or laboratory efficacy tests of ultrasound to repel insects

Page 23: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

2001 FTC Warns Manufacturers and Retailers of Ultrasonic Pest Control Devices

• Efficacy claims about these products must be supported by scientific evidence

• FTC challenged the following types of claims:

-- Eliminates rodent infestations

-- Repels insects

-- Serves as an effective alternative to conventional pest control products

-- Increases or assists the effectiveness of other pest control methods

-- Eliminates fleas on dogs or cats

Source: http://www.ftc.gov/opa/2001/05/fyi0128.htm

Page 24: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Kansas State University (KSU) test results with ultrasonic devices against arthropod pests

(2000-2003)

• 5 commercial devices: A, B, C, D, and E

• 1 random ultrasound-generating unit (developed at KSU)

• 9 groups of arthropod pests

Page 25: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Arthropods used in tests

• Cat fleas, Ctenocephalides felis

• German cockroach, Blattella germanica

• Ants, Camponotus festintatus, C. pennsylvanicus, Formicapallidefulva

• Eastern yellow jacket, Vespula maculifrons

Page 26: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

• Long-bodied cellar spiders,Pholcus phalangioides.

• Field and house crickets, Acheta assimilis, A. domestica

• Fly complex: Green bottle fly (Phormia spp.), flesh fly (Sarcophagidae), house fly (Musca domestica), blow fly, and 2 other unknown fly species

• Imperil scorpion, Pandinusimperator

• Indian meal moth, Plodia interpunctella.

Page 27: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Sound characterization

• Bruel and Kjaer (B&K) type 4939 condenser microphone, B&K type 2670 preamplifier, and B&K NEXUS conditioning amplifier

• Measurements were made at a distance of 50 cm. Units A: 11 devices, B: 11, C:14, C: 3, D: 2, and E: 2 devices

Page 28: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Frequency Spectrum

0102030405060708090

100

0 10 20 30 40 50 60 70 80 90 100

Frequency (kHz)

Sou

nd P

ress

ure

Leve

l (dB

re

20 µ

Pa)

Waveform Graph

-10

-5

0

5

10

15

0 0.02 0.04 0.06 0.08 0.1 0.12

Time (seconds)

Sou

nd P

ress

ure

(Pa)

• 26 and 34 kHz

• SPL = 95 ± 1 dB at 50 cm

Sound characterization, Device A (Mode A & Quiet)

• 0.123 second of one cycle.

• 2 groups of pulses with 8 pulses in each group

Page 29: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Frequency Spectrum

0

20

40

60

80

100

0 20 40 60 80 100Frequency (kHz)

Soun

d Pr

essu

re L

evel

(dB

re

20 µ

Pa)

Waveform Graph

-10-8-6-4-202468

10

0 0.02 0.04 0.06 0.08 0.1 0.12Time (seconds)

Soun

d Pr

essu

re (P

a)

• 21 kHz, 35 kHz, and 41 kHz

• SPL = 94 dB (SPL) at 50 cm distance

Sound characterization, Device A (Mode B & Quiet)

• 0.123 second of one cycle of the sound

• 2 groups of pulses with 8 pulses in each group

Page 30: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Frequency Spectrum

0102030405060708090

100

0 20 40 60 80 100Frequency (kHz)

Soun

d Pres

sure

Leve

l (dB r

e 20

µPa)

Waveform

-15

-10

-5

0

5

10

15

0 0.02 0.04 0.06 0.08 0.1 0.12Time (seconds)

Soun

d Pres

sure

(Pa)

• 27 and 35 kHz

• SPL = 92 ± 4 dB

• 0.123 second for one sound cycle

• 2 groups of pulses with 8 pulses in each group

Sound characterization, Device B

Page 31: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Frequency Spectrum

0

20

40

60

80

100

0 20 40 60 80 100Frequency (kHz)

Soun

d Pre

ssur

e Lev

el (d

B re

20

µPa)

Waveform Graph

-6

-4

-2

0

2

4

6

0 0.01 0.02 0.03 0.04 0.05 0.06 0.07

Time (seconds)

Soun

d Pr

essu

re (P

a)

• A wide range of peak frequencies between 27.7 to 42 kHz

• SPL = 88 ± 2 dB at 50 cm

Sound characterization, Device C

• 0.075 second in duration

• 3 groups of pulses, and each group was characterized by multiple pulses

Page 32: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

• Small peak at 50-60 kHz • SPL = 70 dB sound pressure level at 50 cm

Sound characterization, Device D (Frequency)

Page 33: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

• Several different sound waveform patterns • at least 3 distinct sound patterns

Sound characterization, Device D (Waveform)

Page 34: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

• Peak frequencies at 26 to 40 kHz and at 60 to 80 kHz, plus a small peak frequency at 90 kHz

• SPL = 70 dB at 50 cm

Sound characterization, Device E (Frequency)

Page 35: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

• 0.017 second of one cycle of the sound • 4 -5 groups of pulses with many pulses in each group

Sound characterization, Device E (Waveform)

Page 36: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

KSU random-ultrasound generating system

• an ultrasound generator (left)

• a computer (right) with electrostatic amplifier

• sound frequencies, pulse repetition rates, and quiet time at random

KSU Ultrasonic generator

• Sound parameter settings:-- Min Quiet Time (ms): 50 -- Max Quiet Time (ms): 300-- Min Pulse Time (ms): 50-- Max Pulse Time (ms): 200-- Min number of pulses: 7-- Max number of pulses: 15-- Amplitude: 2.25-- Feeding buzz control: 100-- Frequency: 20 – 80 kHz

Page 37: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

• The computer randomly chooses the pulse length, frequency (20 to100 kHz), and quiet time between pulses across the entire frequencyrange

• One device can drive two ultrasonic emitters simultaneously

• The ultrasonic emitter, on average, produced 95dB at the bottomcenter of the enclosure

• A laptop computer to characterize the output of the ultrasonic emitter

KSU random-ultrasound generating system

Page 38: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Sound frequency spectrum (A) and waveform graph (B) produced by the KSU ultrasonic generator. The figures show change in sound frequencies and waveforms over time

0

1020

30

40

50

60

70

80

90

100

0 10000 20000 30000 40000 50000 60000

0

10

20

30

40

50

60

70

80

90

100

0 10000 20000 30000 40000 50000 60000

Frequency

(Hz)

Soun

d pr

essu

re le

vel (

dB r

e 20

uPa

)

A B

-1.5

-1

-0.5

0

0.5

1

1.5

0 0.01 0.02 0.03 0.04 0.05 0.06

Time (ms)

Soun

d pr

essu

re (p

a)

-1.5

-1

-0.5

0

0.5

1

1.5

0 0.01 0.02 0.03 0.04 0.05 0.06

KSU random-ultrasound generating system

Page 39: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Measurement of sound output inside test enclosures

Page 40: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

• 8 Plexiglas enclosures, 4 x 4 x 4 ft • A 2–3 feet long square conduit (3 x 3 x

3 in) • All sides of each enclosure were divided

into 16 equal quadrats• An unit was mounted on the top corner,

diagonally opposite from the conduit openings, or on the center of the top surface and faced the center of the bottom surface of an enclosure

• Sound pressure level (dB) within an enclosure at the bottom, middle, and top levels for the ultrasonic devices A, B, and C were measured

Test enclosures

Page 41: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Device Bottom Middle Top

A 77-80 89-97 74-79

B 78-84 89-96 76-80

C 78-86 89-106 74-91

Sound pressure level (dB) within an enclosure at the bottom, middle, and

top levels for the ultrasonic devices A, B, and C

Page 42: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Mid.

Contour maps showing distribution of sound pressure levels within an enclosure at the bottom, middle, and top levels for the ultrasonic devices A, B, and C. The device position within an enclosure was at (0,0) coordinates near the top

Top

Bot.

Distance from front left (meters)

Dis

tanc

e fr

om fr

ont l

eft (

met

ers)

A B C

7879808182838485868788899091

89

91

93

95

97

99

101

103

105

74

76

78

80

82

84

86

88

90

Page 43: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Cockroach tests

Page 44: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

• German cockroach • Ultrasonic devices A, B, and C • 100 insects/enclosure • Number of cockroaches was counted each day • 7-days for each test (replicate)• 4 tests for each device and control • Data on the number of cockroaches were analyzed by paired t-tests

Ultrasonic unit

Conduit

Hobo unit

Food

WaterGate

Door

Page 45: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Action # of insects

B A

0 Start Start 100 100

5 on off xxx xxx

6 on off xxx xxx

7 on off xxx xxx

off

off

off

4 on off xxx xxx

xxx

xxx

xxx

Day

A B

1 off xxx

2 on xxx

3 on xxx

Page 46: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

No.

coc

kroa

ches

4 05 06 07 08 09 0

1 0 0

W e s t s id eE a s t s id e

4 05 06 07 08 09 0

1 0 0

In a c tiveA c tive

4 05 06 07 08 09 0

1 0 0

In a c tiveA c tive

D a y s a fte r in s e c t re le a s e1 2 3 4 5 6 7

4 0

5 0

6 0

7 0

8 0

9 0

1 0 0

In a c tiveA c tive

C o n tro l

D e v ice A

D e v ive B

D e v ice C

a

a

b

b

Page 47: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

• The number of cockroaches in the enclosures with active ultrasonic units were consistently lower than those found in theenclosures with inactive units for all three devices throughout the test period

• Paired t-tests indicated that differences in cockroach numbers were not statistically significant (P > 0.05)

• Ultrasound produced from the devices had a marginal effect in repelling cockroaches

• The level of repellency observed may not be of commercial significance

Conclusions

Page 48: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

• It is the most importantectoparasite of companion animals such as cats and dogs

Cat flea tests

Page 49: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

• Artificial flea blood feeding device

• 6 flea feeding sleeves

Artificial flea feeding device

Feeding cup

Water tank

Transonic device

Water pump

Feeding stage

Immersion heater

Page 50: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

• Six 30 ml-plastic cups held the fleas

• Three windows (ca 25 x 15 mm each) were cut around the well of each cup.

• These openings were sealed with a 400-mesh nylon screen to allow ultrasonic pulses to pass through

• Cups were then fitted to the feeding device

Page 51: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

• One end of the feeding sleeve was sealed with parafilm

• 3 ml ox blood was put into each sleeve

• The sleeves with blood were put into the holes of the artificial feeding stage

• The fleas inside the cups were able to imbibe blood from the sleeves through the screens and parafilm

Page 52: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

• Blood was maintained at 39oC through a temperature controllable water circulation system

• The blood was changed every two days

• Each test was run for four days

Page 53: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

• 9 tests: 2 for control, 2 for device A, 4 for device B, and 1 for device C

• Number of fleas feeding in each cup was counted twice daily

• Biomass (feces + flea bodies + eggs) in each cup was weighed

• Number of eggs in each cup was counted

Page 54: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

• Control: 78%

• Treated: 62%

50

55

60

65

70

75

80

Contral T100 T0600 T800

Treatments

% fe

edin

gNumber of fleas feeding

Page 55: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

• Control: 22

• Device A: 25

• Device B: 13

• Device C: 19 10

15

20

25

30

Contral Device A Device B Device C

Treatments

Bio

mas

s (m

g/fe

mal

e)

Biomass (mg/female)

Page 56: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

• Control: 23

• Device A: 25

• Device B: 11

• Device C: 150

5

10

15

20

25

30

Contral Device A Device B Device C

Treatments

# of

egg

s lai

d /fe

mal

e

Egg laying (eggs/female)

Page 57: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Conclusions

• Ultrasonic pulses from device B impacted feeding behavior and reproduction of the cat flea

• No effect from device A

• No clear results for device C (not adequately replicated)

Page 58: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Spider Tests

Page 59: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

• House room tests

• Greenhouse tests

• Enclosure tests

Page 60: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

House room tests

• Devices A, B, C, and a control • 20 rooms • A Pherocon 1C sticky trap was placed on the

floor • An ultrasonic unit was set facing the trap,

about 2 ft away • 5 replications • Number of spiders were checked 5 times

Page 61: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Treatments # of spiders ± SE*

Control 4.2 ± 0.49 aDevice A 2.8 ± 0.80 abDevice B 1.4 ± 0.40 bDevice C 1.6 ± 0.68 b

Number of long-bodied cellar spiders captured per trap and the LSD comparisons

*Values with same letter were not significantly different at the 5% significant level

• About 90% of the spiders captured were long-bodied cellar spiders

• Number of spiders captured with device B and C units was significantly less than the captures from control rooms

• Devices B and C may repel spiders

• Repellent ability of device A was not significant

• Trap captures were low!

Page 62: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Greenhouse paired tests

• Paired design • 9 greenhouse rooms (208 – 625 ft2) • In each room, two sticky traps were placed at the

two corners of the room (pair) • An ultrasonic unit was set facing 1 ft away from

each sticky trap

Page 63: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

• Number of spiders were checked at biweekly intervals

• The sticky traps were replaced after each observation

Page 64: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Treatments # of spiders ± MSE difference t-value P-value

Control 2.00 ± 0.00 Device A 1.67 ± 0.88 0.33 ± 0.88 0.3780 0.7418

Control 2.00 ± 0.58 Device B 2.67 ± 1.45 -0.67 ± 1.33 -0.5000 0.6667

Control 4.00 ± 0.58Device C 1.00 ± 0.58 3.00 ± 0.58 5.1962 0.0351

Total number of spiders captured in each spot and the t-test results

Page 65: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Enclosure tests

• Long-boded cellar spiders from Carolina supplies

• Devices A and C

• Same procedure as used in the cockroach tests

• 15 spiders/pair of enclosures

• 3 paired tests/device

The movements of the spiders was not affected by the ultrasound emitted from any of the tested devices

Page 66: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Cricket Cricket tests

Page 67: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

• Field cricket and house crickets

• Greenhouse tests, similar to spider tests

• Enclosure tests, similar to cockroach tests

Page 68: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Greenhouse tests

• The ultrasonic units did not repel the field cricket under the greenhouse test conditions

Page 69: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

• House cricket purchased from Carolina supplies

• Devices A, C, D, E, and KSU unit

• 50 crickets/enclosure• Replications: 3 for A and C, 1

for D and E, and 2 for KSU unit

Enclosure tests

Page 70: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

• Number of crickets were counted daily

• 5-day test was a replicate• Strip-split-plot design

Action # of insects

B A

0 Start Start 100 100

off

off

off

4 off on xxx xxx

on

xxx

xxx

xxx

xxx

Day

A B

1 off xxx

2 on xxx

3 on xxx

5 off xxx

Page 71: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

-30

-20

-10

0

10

20

30

1 2 3 4

OffOn

Days

Cha

nge

in n

umb e

r of

cri

cket

s

Device A test results

Page 72: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

-30

-20

-10

0

10

20

30

1 2 3 4

Off On

Days

Cha

nge

in n

umbe

r o f

cr i

cke t

s

Device C test results

Page 73: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

-30-25-20-15-10-505

1015202530

1 2 3 4

Off On

Days

Cha

nge

in n

umbe

r of

cri

cket

s

Device D test results

Page 74: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

-30

-20

-10

0

10

20

30

1 2 3 4

Off On

Days

Device E test results

Cha

nge

in n

umbe

r of

cri

cket

s

Page 75: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

-30

-20

-10

0

10

20

30

1 2 3 4

Off On

Days

Cha

nge

in n

umbe

r of

cr i

cke t

s

KSU device test results

Page 76: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Conclusions

• Devices A and C significantly repelled crickets. KSU unit repelled more crickets than A and C devices

• Device D and E performed poorly

Page 77: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Field Evaluation of three commercial Field Evaluation of three commercial ultrasonic devices in repelling flies and ultrasonic devices in repelling flies and

the eastern the eastern yellowjacket yellowjacket

Page 78: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Yellow jacket and Fly Tests

• Device A, B, and C.• 18 metal buckets of 19.5-liter capacity

were filled with fruits and pork meat mixed with trash

• One yellow jacket/fly sticky trap was taped upside down over the opening of each bucket

• Tuttle Creek Park at Manhattan, Kansas, with a 6.1 m distance between any two adjacent buckets

• Completely random design with 3 replicates

• After 10 days, insects in the sticky traps and buckets were recorded

Page 79: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Yellow jacket and Fly tests results

Device Status Fly complex# captured

Yellow jacket # captured

Inactive 13.3 ± 3.5 a 33.0 ± 5.9 a

Active 16.7 ± 7.5 a 14.7 ± 6.3 b

Inactive 10.3 ± 5.8 a 19.3 ± 4.4 ab

Active 22.0 ± 11.4 a 10.3 ± 3.9 b

Inactive 15.3 ± 4.6 a 22.7 ± 9.0 ab

Active 20.3 ± 3.8 a 15.3 ± 2.2 ab

C

B

A

• Ultrasound produced from the three commercial devices failed to repel the fly complex

• Partially effective against the eastern yellowjacket

Page 80: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Ant tests

• Enclosure tests, similar to cockroach tests

• Open field test, similar as fly and yellow jacket tests

Page 81: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Enclosure test results

• No significant ant movement in the enclosures in the presence or absence of ultrasound

• Failed to repel ants

Page 82: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Open field test resultsTreatment Number of ants (Mean + SE)

Device StatusIn trap Inside trashcan Totala

A

B

C

Off

On

Off

On

Off

On

1.7 ± 1.7 8.0 ± 4.0 9.7 ± 5.7

3.3 ± 2.4 6.0 ± 5.5 9.3 ± 7.8

7.0 ± 7.0 7.0 ± 2.6 14.0 ± 7.0

2.0 ± 2.0 7.3 ± 2.6 9.3 ± 1.5

2.7 ± 2.7 10.0 ± 6.2 12.7 ± 8.8

14.3 ± 12.4 11.3 ± 7.0 25.7 ± 12.8

• Failed to repel ants in field trials

Page 83: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Scorpion tests

Page 84: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Scorpion test procedure

• Enclosure tests

• Imperil scorpion, Pandinus imperator

• Devices A and C

• For each ultrasonic device, 6 separate tests were conducted

• In each test, a scorpion (adult) was released into one of the paired enclosures and allowed to acclimate to the environment for 24 hours (day 0)

• After 24 h, the ultrasonic unit in one of the enclosures, in which the scorpion was located at that time was turned on for 7 days. The ultrasonic unit in the other enclosure remained off for the duration of the test

• The location of the scorpion was observed and recorded once a day

Page 85: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Scorpion test results

Device Status Times found in enclosure

(%)Inactive 68.4

Active 32.6

Inactive 68.4

Active 32.6

B

A

• The scorpions were more frequently found in the enclosure without ultrasound than in the enclosure with ultrasound

• 26 times the scorpions were located in the enclosure without ultrasound and only 12 times they were found in the enclosure with ultrasound across the six tests

• The limited data indicated that scorpions may respond to ultrasound produced by the two devices

Page 86: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Indian meal moth tests: effects on reproductive performance

Page 87: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

• Device A and dKSU unit.• Paired plexiglass enclosures • 16 dishes or plastic sheets containing

diet were placed in the base of the enclosures

• 10 pairs of newly emerged adults were released in each enclosure

• One ultrasonic device was turned on all the time and the another one was kept off at the same time or without an ultrasonic unit

• IMM distributions were recorded once or twice a day

• Number of larvae was checked after 18-30 days

• Dead females dissected to count spermatophores

Page 88: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

• 2 transducers in one enclosure connected to a rotating arm

• Initial settings:-- Min Quiet Time (ms): 50.00-- Max Quiet Time (ms): 500.00-- Min Pulse Time (ms): 50.00-- Max Pulse Time (ms): 200-- Min Step Size (Hz): 1000-- Max Step Size (Hz): 5000-- Amplitude: 2.25-- Frequency: 20,000-80,000 Hz

KSU unit

Page 89: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Indian meal moth test results, Device A

0

400

800

1200

1600

Off On

# la

rvae

/enc

losu

re

0

800

1600

2400

3200

4000

4800

Off On

Tot

al la

rval

wt /

en (m

g)

0

0.5

1

1.5

2

2.5

3

Off On

Lar

val w

t /L

arva

(mg)

0

0.5

1

1.5

2

2.5

Off On# sp

erm

atop

hore

s/fe

mal

e

Number of larvae (I), larval weight (II & III), and spermatophores (IV) of Indianmeal moth under ultrasound exposure emitted from Device A

I II

IVIII

a

aa

a

ba

bb

Page 90: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Indian meal moth test results, KSU device

0

400

800

1200

1600

2000

no unt On

# la

rvae

/enc

losu

re

0

2000

4000

6000

8000

No unit On

Tot

al la

rval

wt /

en (m

g)

00.5

11.5

22.5

3

3.54

4.55

No unit On

Lar

val w

t /L

arva

(mg)

0

0.5

1

1.5

2

2.5

No nuit On# sp

erm

atop

h ore

s/fe

mal

e

Number of larvae (I), larval weight (II & III), and spermatophores (IV) of Indianmeal moth under ultrasound exposure emitted from KSU unit

I II

IVIII

a

aa

a

b

a

bb

Page 91: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Conclusions

• 46% less number of larvae, and 57 % less total larval weight were observed

• A female had an average of 1.4 spermatophores under ultrasonic exposure compared to 2 spermatophores in the absence of ultrasound (control)

Page 92: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Effects of ultrasound on adult movement, courtship, and mating

behaviors of Indian meal moth

Page 93: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

No.

mot

hs in

cal

ling

1

3

5

7

9

11

13

15

Without ultrasoundWith ultrasound

Time

0

2

4

6

8

10

12

14

Without ultrasoundWith ultrasound

21:00 23:00 1:00 3:00 5:00 7:00

Device A

KSU Unit

Results Female calling• Calling occurred at

night

• Less number of females were calling when exposed to ultrasound

• The difference was significant between 11:00 pm to 3:00 am

Page 94: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Adult movements• Very little movement on day 1 and during day time

• Most movement occurred at night

• No obvious difference between control and ultrasound exposed moths

Num

ber o

f ins

ects

0

2

4

6

8ControlDevice AKSU unit

0

2

4

6

8

0

24

6

8

02

46

8

0

2

4

6

8

17:00 19:00 21:00 23:00 1:00 3:00 5:00 7:00 9:00 11:00 13:00 15:00

Tim e (h)

Day 1

Day 5

Day 4

Day 3

Day 2

Page 95: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Day 1N

umbe

r of i

nsec

ts in

mat

ing

01234

ControlDevice AKSU unit

01234 Day 2

01234

01234

01234

ControlCix 0600KSU unit

Day 4

Day 3

Day 5

17:00 19:00 21:00 23:00 1:00 3:00 5:00 7:00 16:00

Time (h)

Mating activity• No mating occurred

during the day time

• Most matings occurred during the first night and between 9 pm and 11 pm

• No clear difference between control and under ultrasound exposed moths

Page 96: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

0102030405060

Freq

uenc

y (%

)

0102030405060

Mating duration (min) < 30 min 30 - 60 60 - 90 90 - 120 > 120

0102030405060

• A pair mated 3 times during their life time

• Significantly less number of matings occurred under ultrasound exposures

• Most matings lasted for 30 to 90 min without ultrasound

• More matings lasted for less than 30 min or more than 90 min under ultrasound exposure

Without ultrasound

Device A

KSU unit

2.9 matings/female

2.1 matings/female

1.7 matings/female

Mating duration

Page 97: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

0

1

2

3

Control Cix 0600 KSU Unit

No.

sper

mat

opho

res/

fem

ale A

BB

0

50

100

150

200

250

Control Cix 0600 KSU Unit

A

BC

No.

egg

s/fe

mal

e

50

60

70

80

90

100

Control Cix 0600 KSU Unit

AA

B

Egg

via

bilit

y (%

)

• Ultrasound had significant impact on spermatophore transfer, number of eggs laid, and egg viability

Spermatophore transfer and reproduction

Page 98: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Ultrasound as a pest exclusion method

Page 99: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Repellency test resultsDevice Status Without diet With diet

Enclosure A Enclosure B Enclosure A Enclosure B

Control 53.6 ± 6.5 a 53.4 ± 6.8 a 88.6 ± 5.5 a 93.6 ± 4.6 a

Device A A active 68.6 ± 3.2 a 71.8 ± 3.1 a 78.8 ± 11.4 a 107.0 ± 18.1 a

B active 72.0 ± 10.7 a 68.6 ± 3.5 a 124.0 ± 14.4 a 87.0 ± 18.0 a

KSU device A active 70.6 ± 7.8 a 61.6 ± 7.0 a 67.0 ± 7.9 b 98.0 ± 8.0 a

B active 113.8 ± 7.9 a 81.6 ± 4.1 b 109.6 ± 14.9 a 85.0 ± 101.5 a

• The number of moths found in the enclosures with ultrasonic units were consistently fewer than those found in enclosures without ultrasonic units

• For device A, this difference was not significant (P > 0.05).

• For the KSU device, the differences were significant at the 10% level; and 2 out the 4 treatment combinations were significant at the 5% level

Page 100: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

• Cat flea:

• Cockroach:

• Ant:

• Spider:

• Y. jacket:

• Cricket:

• Fly:

• Scorpion

• IMM

Key: Fair No effectUnclearGood

A B C D E KSUDevices

Summary of KSU tests

Page 101: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Overall Conclusions• The effectiveness of devices against arthropod

pests cannot be ascertained without testing specific ultrasonic units

• Effectiveness varies with the protocol used• Most tests are not done under “real world”

conditions (background noises!)• Repellency may not be the only criteria to

evaluate effectiveness of ultrasonic units• Best results were obtained with a tympanate moth

Page 102: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)

Future research needs• Need to develop protocols for evaluating devices that reflect the

“real world”• Are devices being used for preventing or repelling infestations?• Combination treatments should be explored

– Light + ultrasound; ultrasonic barriers; ultrasound and attractants (push-pull strategy)

• Can environmental conditions within homes be altered for better performance of these devices?

• Need electrophysiological assays to ascertain effects (also for quick screening)

• Need to explore frequency ranges and pulse durations that give the best response (e.g., ranges above 45 kHz)

• May not have a promising future if existing devices are not improved through scientific and market research

Page 103: Ultrasound and Arthropod Pest Control: Hearing is Believing! · Sound Pressure Level (dB re 20 µPa) Waveform Graph -10-8-6-4-2 0 2 4 6 8 10 0 0.02 0.04 0.06 0.08 0.1 0.12 Time (seconds)