ultrasonic scaling at a precise and steady...
TRANSCRIPT
4 5
Ultrasonic scaling at a precise and steady
vibration prevents damage of the natural
tooth structure. Ten versions of NSK Varios
Scaling tips allow the removal of supragingival
calculus, interdental calculus, and calculus at
the tooth neck.
SCAL ING
6 7Refer to the power setting chart on pages 44-45.Satelec® is registered trademarks of Acteon SA, France. EMS® is registered trademarks of Electro Medical Systems SA, Switzerland.
S C A L I N G
G1To remove calculus on anterior teeth, the neck of molars, and supragingival calculus, the side of the Varios tip should beplaced on the tooth and moved sideways.
G2To remove heavy calculus place the top of the G2 flat tip against the tooth plane and activitate the ultrasonic scaler.
G3To remove heavy nicotine stains, place the top and the side of the tip on the tooth plane and gently move the tip up anddown.
20.0
11.1
MODEL ORDER CODE
Z217-101
Z291-101
G1
G1-E
Z217-102
Z291-102
G2
G2-E
Z217-103
Z291-103
G3
G3-E
G4Removal of subgingival and interdental calculus from anterior and molar teeth. To remove calculus from anterior teeth,place the top of the tip on the neck of the tooth and move it along the tooth plane.
G5To remove interdental calculus and calculus in pockets, insert the tip between the teeth while touching the tip on the tooth.
G6Insert the tip between teeth and remove calculus while keeping the top of the tip on the tooth plane to remove tartar.
MODEL ORDER CODE
Z217-104
Z291-104
G4
G4-E
Z217-106
Z291-106
G6
G6-E
NSK
Satelec® Z217-105G5
7.2
23.3
23.4
7.0
8.1
23.0
20.1
11.2
23.2
11.4
NSK
Satelec®
EMS®
NSK
Satelec®
EMS®
NSK
Satelec®
EMS®
NSK
Satelec®
EMS®
NSK
Satelec®
EMS®
8 Satelec® is registered trademarks of Acteon SA, France. 9Refer to the power setting chart on pages 44-45.
S C A L I N G
G7Removal of interdental heavy calculus.
G11Universal type. Removal of calculus from a wide plane such as anterior teeth.
G12Perio type. The tip with the sharp angle removes calculus of the molar.
NSK
Satelec® Z217-411G11
MODEL ORDER CODE
NSK
Satelec® Z217-107G7
NSK
Satelec® Z217-412G12
G13Sickle type. It is suitable for removing calculus of the neck and interdental calculus.
MODEL ORDER CODE
NSK
Satelec® Z217-413G1323.3
8.8
23.1
6.9
22.9
7.4
6.7
22.2
10 11
Varios tips, angled from right and left,
plus straight, are available to provide
the best approach to furcation and
curved root faces.
P E R I O
12 Satelec® is registered trademarks of Acteon SA, France. 13Refer to the power setting chart on pages 44-45.
27.0
7.4
P E R I O ( R O O T P L A N I N G )
P1
• Diamond coated
P1DP1D is diamond coated tip and its shape is the same as P1 tip. Designed for the removal of fine calculus and for the finishing of root planing.
P10To remove subgingival stains, the tip may be used as per manual curettes.
P2D
P2D Right curved tip
P3D Left curved tip
Diamond coated tip effectively removes persistent subgingival calculus.Right curved tip.
P3DLeft curved tip.
• Sharp edge
Ultra thin tips provide easy access to anterior teeth, narrow pockets and complex crowded teeth.
P2D / P3D (From above)
MODEL ORDER CODE
NSK
Satelec® Z217-404P1
NSK
Satelec® Z217-405P1D
NSK
Satelec® Z217-410P10
MODEL ORDER CODE
NSK
Satelec® Z217-402P2D
NSK
Satelec® Z217-403P3D
27.0
6.9
27.0
6.9
31.6
6.8
27.0
7.4
• Diamond coated
• Diamond coated
Per io Ki t A
NSK
Satelec® Y900-144Perio Kit A
• P1D, P2D, P3D, P10 : 1 pc. each
• Tip holder : 1 pc.
14 15Refer to the power setting chart on pages 44-45.Satelec® is registered trademarks of Acteon SA, France. EMS® is registered trademarks of Electro Medical Systems SA, Switzerland.
P21RRight curved tip.
P E R I O ( R O O T P L A N I N G )
P21LLeft curved tip.
P20Straight tip.
P25RFor root planning of molar furcation and complicated curve.Right curved tip.
P25LLeft curved tip.
MODEL ORDER CODE
Z217-420
Z291-420
P20
P20-E
Z217-422
Z291-422
P21R
P21R-E
MODEL ORDER CODE
Z217-424
Z291-424
P25R
P25R-E
Z217-425
Z291-425
P25L
P25L-E
Z217-421
Z291-421
P21L
P21L-E
P21R Right curved tip
P20 Straight tip
P21L Left curved tip
P25R Right curved tip
P25L Left curved tip
P21R / P20 / P21L / P25R / P25L (From above)
28.5
12.3
27.7
11.4
27.7
11.4
27.2
7.6
27.2
7.6
NSK
Satelec®
EMS®
NSK
Satelec®
EMS®
NSK
Satelec®
EMS®
NSK
Satelec®
EMS®
NSK
Satelec®
EMS®
Per io Ki t B
NSK
Satelec® Y900-145Perio Kit B
• P20, P25R, P25L : 1 pc. each
• Tip holder : 1 pc.
16 Satelec® is registered trademarks of Acteon SA, France. 17Refer to the power setting chart on pages 44-45.
14.8
7.9
P41
P E R I O ( I r r igat ing and C lean ing ) MAINTENANCE (V-T ip)
P40
MODEL ORDER CODE
NSK
Satelec® Z217-550P40
NSK
Satelec® Z217-555P41
Y900-184V-P10
V-P10• Pack of 3
V10
*Plastic Tip is not included
MODEL ORDER CODE
NSK
Satelec® Z217-041V10
17.8
28.9
3
6
14.7
ø 0.6
28.9
14.4
ø 0.8
3
6
Dual irrigation points
• Irrigation from dual points on lateral areas of the apex.
• Effective cleaning regardless of the insertion angle.
• Safe to use regardless of the pocket condition due to the marking
guideline of 3 mm from the position of 6 mm.
• The rounded apex shape for safety in periodontium.
For effective cleaning following debridement or scaling. For the maintenance of prostheses and implants.
Produced from special material to allow safe debridement
without causing damage to metals and implants.
• Tip diameter ø 0.6 mm
• Tip diameter ø 0.8 mm
NSK offers endodontic tips to achieve quick
and effective treatments for root canal
enlarging, irrigation, and filling. File and
diamond tips for root canal enlarging, tips
for root canal irrigation, tips for gutta-percha
filling, tips for removal of materials and
foreign bodies in root canal.
18 19
ENDODONTICS
20 Satelec® is registered trademarks of Acteon SA, France. 21Refer to the power setting chart on pages 44-45.
ENDODONTICS
E4Application for root canal cleaning and removal of foreign particles.
E7Removal of filling and foreign material.
E8
28.4
26.0
8
29.6
• Water not required
• Water not required
E4D
E7DEnlargement of root canal wall.
E8D
• Diamond coated
• Diamond coated
• Diamond coated
MODEL ORDER CODE
NSK
Satelec® Z217-428E4
MODEL ORDER CODE
NSK
Satelec® Z217-528E4D
NSK
Satelec® Z217-317E7D
NSK
Satelec® Z217-318E8D
NSK
Satelec® Z217-307E7
NSK
Satelec® Z217-308E8
24.1
16.0
20.6
Enlargement of root canal wall.
24.1
16.0
13.0
20.6
with diamond
28.4
26.0
23.0
29.6
with diamond
23.2
15.8
14.6
23.2
15.8
14.6
10.0 with diamond
Removal of filling and foreign material.
Application for root canal cleaning and root canal enlargement.
In order to reduce the
incidence of ledge formation,
no diamond coating is
attached from the end up to
1mm of the tip.
*
1.0
22 Satelec® is registered trademarks of Acteon SA, France. 23Refer to the power setting chart on pages 44-45.
E5Lateral condensation.
E6
Endo Ki t E11
Lateral condensation.
• Water not required
• Water not required
U f i lesLength : 33 mmShank dia. : 0.8 mm
• For U files (Shank dia : 0.8 mm) • For root canal cleaning • For anterior teeth• Includes E Tip replacement wrench
*File is optional
• For U files (Shank dia : 0.8 mm) • For root canal cleaning • For posterior teeth• Includes E Tip replacement wrench
*File is optional
• ISO15 • Pack of 6
• ISO20 • Pack of 6
• ISO25 • Pack of 6
• ISO30 • Pack of 6
• ISO35 • Pack of 6
MODEL ORDER CODE
NSK
Satelec® Z217-305E5
MODEL ORDER CODE
NSK
Satelec® Z217-031E11
NSK
Satelec® Z217-032E12
NSK
Satelec® Z217-306E6
NSK
Satelec® Y900-146Endo Kit E11
Y900-062
Y900-063
Y900-064
Y900-065
Y900-066
U files 33 mm / #15
U files 33 mm / #20
U files 33 mm / #25
U files 33 mm / #30
U files 33 mm / #35
• E11 : 1 pc.
• E Tip replacement wrench : 1 pc.
• U files 33 mm #15, #20, #25, #30, #35 :
Pack of 6 each size
NSK
Satelec® Y900-147Endo Kit E12
• E12 : 1 pc.
• E Tip replacement wrench : 1 pc.
• U files 33 mm #15, #20, #25, #30, #35 :
Pack of 6 each size
21.5
17.0 21.5
24.3
20.0
21.3
15.2
12.8
12.6
95 16.2
E11120˚ Angle Holder for U files
E1295˚ Angle Holder for U files
for anterior teeth
Endo Ki t E12for posterior teeth
ENDODONTICS
25Refer to the power setting chart on pages 44-45.24 Satelec® is registered trademarks of Acteon SA, France.
ENDODONTICS (V-Tip)
V-S50
ø1.5
12.6
ø1.5
18.2
ø1.5
21.2
ø1.5
27.2
• For root canal cleaning 17 mm• Pack of 3
V-S51• For root canal cleaning 23 mm• Pack of 3
V-S52• For root canal cleaning 26 mm• Pack of 3
V-S53• For root canal cleaning
32 mm• Pack of 3
Y900-169V-S50
Y900-170V-S51
Y900-171V-S52
Y900-172V-S53
Y900-173V-S50D
Y900-174V-S51D
Y900-175V-S52D
Y900-176V-S53D
ø1.5
12.6
9.1 with diamond
ø1.5ø1.5
16.0 with diamond
18.2
ø1.5
19.0 with diamond
21.2
ø1.5
25.0 with diamond
27.2
V30
In order to reduce the incidence of
ledge formation, no diamond coating
is attached from the end up to 1mm
of the tip.
• Includes E Tip replacement wrench
*Tip is optional• Includes E Tip replacement wrench
*Tip is optional
MODEL ORDER CODE
NSK
Satelec® Z217-030V30
29.5
8.3
MODEL ORDER CODE
NSK
Satelec® Z217-030V30
29.5
8.3
V-S50D• Diamond coated• For root canal enlargement 17 mm• Pack of 3
V-S51D• Diamond coated• For root canal enlargement 23 mm• Pack of 3
V-S52D• Diamond coated• For root canal enlargement 26 mm• Pack of 3
V-S53D• Diamond coated• For root canal enlargement
32 mm• Pack of 3
For Root Canal Cleaning For Root Canal Enlargement
V30
1.0 *
27Refer to the power setting chart on pages 44-45.26 Satelec® is registered trademarks of Acteon SA, France.
The microscopic diamond coated tip allows effective removal of dentin at the apex.
2 types of angled tips (90°, 70°) are available for anterior teeth and another 2 types
of curved tips (right and left) are available for molar.
RETROGRADE ENDO
E32D
• Diamond coated• For anterior and posterior teeth (70˚)
• Diamond coated• For anterior teeth (90˚)
Diamond coated tip allows efficient cavity preparation.
E31DDiamond coated tip allows efficient cavity preparation.
NSK
Satelec® Z217-211E32D
MODEL ORDER CODE
NSK
Satelec® Z217-210E31D
18.9
13.4
17.8
12.5
E30RD
E30LD
Diamond coated tip allows efficient cavity preparation.
20.2
12.2 MODEL ORDER CODE
NSK
Satelec® Z217-212E30RD
NSK
Satelec® Z217-213E30LD20.2
12.2
• Diamond coated• For posterior teeth (right angled)
• Diamond coated• For posterior teeth (left angled)
NSK
Satelec® Y900-149Retro Kit
• E30RD, E30LD, E31D, E32D : 1 pc. each
• Tip holder : 1 pc.
Retro Ki t
Diamond coated tip allows efficient cavity preparation.
28 29
Ultrasonic vibration is applied to the tooth
surface. The compact handpiece is ideal for
small mouths and at sites where a rotary
handpiece is difficult to access. A variety of
tips are available for caries removal and
tooth surface characterization.
RESTORATIVE
31Refer to the power setting chart on pages 44-45.30 Satelec® is registered trademarks of Acteon SA, France.
0.9
1.5
0.6
1.0
F o r M i n i m a l I n t e r v e n t i o n
R E S T O R AT I V E ( V- T i p )
Y900-118V-G70
Y900-119V-G71
Y900-121V-G75
Y900-122V-G76
Y900-120V-G72
ø1.5
12.3
ø1.5
12.0V-G70
• Diamond coated• Pack of 3
V-G71• Diamond coated• Pack of 3
V-G72• Diamond coated• Pack of 3
• Includes E Tip replacement wrench
*Tip is optional
MODEL ORDER CODE
NSK
Satelec® Z217-030V30
29.5
8.3
• Includes E Tip replacement wrench
*Tip is optional
MODEL ORDER CODE
NSK
Satelec® Z217-030V30
29.5
8.3
ø 1.2
ø 0.8
ø 1.6 ø1.5
12.8
ø1.5
12.5
ø1.5
12.5
V-G75
• Diamond coated• Pack of 3
V-G76• Diamond coated• Pack of 3
V30 V30
• V-G70, V-G71, V-G72, V-G75,
V-G76 : 1 pc. each
Assorted Tip Ki t
NSK
Satelec® Y900-150MI Starter Kit
• V30 V-tip holder : 1 pc
• E Tip replacement wrench : 1 pc
• V-G70, V-G71, V-G72, V-S1, V-S3, V-S33
V-G77, V-G78, V-G79 : 1 pc. each
MI Starter Ki t
The NSK Varios V-Tip System has been developed to meet “Minimal Intervention”
dental procedures. As a variation to rotary cutting, the Varios V-Tip offers precise
and effective ultrasonic technology cutting. The advantage of ultrasonic cutting
decay removal is that tip movement is minute allowing only decayed dentine to be
removed, while sound dentine is preserved.
Y900-158AssortedTip Kit
32 Satelec® is registered trademarks of Acteon SA, France. 33Refer to the power setting chart on pages 44-45.
ø1.5
12.5
ø1.5
12.5
ø1.5
12.5
For F in ish ing / Tr imming / Pol ish ing
R E S T O R AT I V E ( V- T i p )F o r C a r i e s o f D e n t i n
R E S T O R AT I V E ( V- T i p )
V-S1• Stainless tip• Pack of 3
V-S3• Stainless tip• Pack of 3
V-S33• Stainless tip• Pack of 3
Y900-165V-G77
Y900-166V-G78
Y900-167V-G79
Y900-168AssortedTip Kit
Y900-161V-S1
Y900-162V-S3
Y900-163V-S33
ø1.5
12.5
ø 0.8
0.9
ø 1.1
1.2
ø1.5
12.5
ø1.5
12.5
ø 0.8
2.6
V-S1, V-S3 and V-S33 are very effective in minimal intervention cavity preparation.
3 types of tips are available in response to cavity preparation requirements.
V-G77Normal grade
Three grades of diamond particles are available – Normal, Fine and Super
Fine – for tooth surface characterization to polishing.
ø 1.2
ø 1.2
ø 1.2
4.5
4.5
4.5
• Diamond coated• Pack of 3
V-G78Fine grade
• Diamond coated• Pack of 3
V-G79Super fine grade
• Diamond coated• Pack of 3
V30 V30
• Includes E Tip replacement wrench
*Tip is optional
MODEL ORDER CODE
NSK
Satelec® Z217-030V30
29.5
8.3
• Includes E Tip replacement wrench
*Tip is optional
MODEL ORDER CODE
NSK
Satelec® Z217-030V30
29.5
8.3
Assorted Tip Ki t
• V-G77, V-G78, V-G79 : 1 pc. each
Y900-164AssortedTip Kit
• V-S1, V-S3, V-S33 : 1 pc. each
Assorted Tip Ki t
34 Satelec® is registered trademarks of Acteon SA, France. 35Refer to the power setting chart on pages 44-45.
F o r M i n i m a l I n t e r v e n t i o n
R E S T O R AT I V E
G61DUse the tip with the spherical diamond at the top. Bleeding scarcely occurs. (G61D / G62D)
G62D
MODEL ORDER CODE
NSK
Satelec® Z217-601G61D
NSK
Satelec® Z217-602G62D
28.0
7.8
28.0
7.9
G65DFor molar, interdental proximal caries. The hemispherical top of the tip does not allow cutting of sound tooth.(G65D / G67D / G66D / G68D)
NSK
Satelec® Z217-605G65D27.9
7.6
• Diamond coated
• Diamond coated
• Diamond coated
G66DFor anterior proximal caries. Only decayed dentin can be removed as per for molars.(G65D / G67D / G66D / G68D)
G68D
NSK
Satelec® Z217-606G66D
NSK
Satelec® Z217-608G68D
27.6
7.7
27.8
8.0
G67D
MODEL ORDER CODE
NSK
Satelec® Z217-607G67D28.2
7.8
• Diamond coated
• Diamond coated
• Diamond coated
0.9
1.0
1.23
1.4
1.33
0.75
1.63
1.0
1.330.75
1.631.0
36 37
Tips for the removal of prostheses, for amalgam
filling condensation are provided as well as for
scaling, perio and endodontic.PROSTHETICS
38 Satelec® is registered trademarks of Acteon SA, France. 39Refer to the power setting chart on pages 44-45.
G26Post removal.
G28Amalgam condensation.
• Water not required
G25Crown removal.
• Water not required
MODEL ORDER CODE
NSK
Satelec®Z217-205G25
MODEL ORDER CODE
NSK
Satelec® Z217-010G21
NSK
Satelec® Z217-020G22NSK
Satelec® Z217-206G26
NSK
Satelec® Z217-208G28
Condensation / Loosening / Plugging
P R O S T H E T I C S
Ultrasonic vibration removes bubbles in the cement for precise cementation.
• For anterior teeth • Water not required• 3 caps supplied
• For posterior teeth• Water not required• 3 caps supplied
G21
G22
Tip Cap
Ultrasonic vibration removes bubbles in the cement for precise cementation.
9.1
25.7
23.6
10.8
23.2
9.0
ø1.65
23.9
7.6
ø1.3
22.9
9.0
• For G21 / G22• Pack of 10
• Autoclavable
Y140-751Tip Cap