ultra-seal elastomeric roof coating...sur f ace to be coated with intended a fine mist f clean r...
TRANSCRIPT
ULTRA-SEALELASTOMERICROOF COATING
RESIN: 100% Acrylic Emulsion
COLOR: Brilliant White
GLOSS: Low LusterSOLIDS BY WEIGHT: 64.5%SOLIDS BY VOLUME: 53.5%VISCOSITY: 116KU@75FVAPOR TRANSMISSION: 4.8 Perms or greater
ELONGATION FACTOR: 300%or higher
WEIGHT PER GALLON:12.9 lbs.
FLASH POINT: None
RECOMMENDED COVERAGE:100 sq. ft. per gallon, per coat,always apply in two light coats.
DRYING TIME@70F&50%RH:To touch: 1 hourTo recoat: 1 to 2 hoursFull cure: 7 to 10 daysDrying times are influenced byambient temperature and relativehumidity. Do not apply whentemperature is below 50F.
CLEANUP: Water
1250AVAILABLE SIZES1 GALLON CAN5 GALLON PAIL
Anvil Paints & Coatings, Inc. 1255 Starkey Road • Largo, FL 33771 FAX 727.535.1413 1.800.822.6776www.anvilpaints.com
100% A
CR
YLIC
RE
SIN
EN
ER
GY
STA
R PA
RT
NE
R
BR
ILLIAN
T W
HIT
E
INSU
LAT
ION
FRO
M N
OISE
AN
D H
EAT
INC
RE
ASE
D A
DH
ESIO
N
HIG
H E
LON
GAT
ION
EA
SY T
O A
PP
LY
5 YE
AR
WA
RR
AN
TY
DESC
RIPT
ION
Anvil #1250 U
ltra-Seal #1 Elastomeric R
oof Coating is our prem
iumhigh build 100%
acrylic elastomeric roof coating based on the latest
chemical technology. D
esigned to seal, protect, and insulate well
drained roof surfaces.
USES
• Mobile H
ome Roofs
• Metal Roofs
• Built U
p Roofs• C
oncrete Roofs• A
sphalt Shingle Roofs• W
ood RoofsD
o not use on P
UF (polyu
rethane foam roofing). D
o not use on flat
roofs. Roof m
ust have adequ
ate pitch to allow w
ater to run off.
SUR
FAC
E PREPA
RAT
ION
All surfaces m
ust be clean and free of dirt, dust, grease, oil, mildew
,and other surfaces contam
inants. Before coating, surface m
ust bedry and firm
. Cut out all blisters and delam
inated bulges from asphalt.
Remove all m
oss, algae, and mildew
with a suitable fungicide applied
according to manufacturer’s instructions. D
egrease galvanized,alum
inum, and other m
etal with a cleaner/degreaser. Sand blast or
wire brush to rem
ove any rust and scale. Wash all other non-porous
substrates with a m
ild detergent solution before continuing with
surface conditioning.
SUR
FAC
E CO
ND
ITIO
NIN
GST
EEL, SLATE, A
LUM
INU
M, W
OO
D, G
ALVA
NIZ
ED M
ETAL, A
ND
OT
HER
NO
N-PO
ROU
S SUR
FAC
ES: Apply one (1) coat of A
nvil#1606 P
rimer. Stir prim
er well prior to application. B
rush or rollprim
er. Do not exceed recom
mended coverage rate. D
o not applyprim
er when relative hum
idity is above 95% or tem
perature isbelow
50º F. or above 95º F. or when these conditions m
ight occurw
ithin one (1) hour after application. Allow
to dry two (2) to four
(4) hours depending on weather conditions.
EXIST
ING
CO
ATIN
GS: C
halky surfaces - Wash, allow
to dry, andapply A
nvil #230 Chalky Su
rface Sealer and allow to dry tw
o (2) tofour (4) hours before continuing. Slight rust - W
ash, allow to dry,
wire brush, and spot prim
e with A
nvil #1606 Prim
er . Allow
to drytw
o (2) to four (4) hours before continuing. Good condition - W
ashand allow
to dry before continuing.JO
INT
S, SEAM
S, AN
D C
RA
CK
S: Clean thoroughly and rem
ove allloose m
aterial. Apply one (1) coat of A
nvil #1220 Seam Seal to all
properly conditioned horizontal or v ertical seams. Seal around all
flashings, openings, and pipe joints with A
nvil #1200 Acrylic Latex
Cau
lk. Press Anvil Polyester M
embrane firm
ly into freshly appliedA
nvil #1220 Seam Seal. Follow
ridge contour or depression of theseam
with the m
embrane. Sm
ooth over with brush or roller to insure
complete w
etting and to leave finish free of stretches or creases inthe m
embrane. A
llow to dry tw
o (2) to four (4) hours allowing for
weather conditions. D
o not apply on overcast days or when possibility
of rain exists w
ithin
four (4) h
ours after ap
plication
. Ap
ply at
temperatures betw
een 50º F. and 95º F. Apply a second coat of
Anvil #1220 Seam
Seal on top and allow to dry six (6) to eight (8)
hours before continuing.
APPLIC
ATIO
ND
o not apply during, just before, or just after rain or when hum
idityis above 95%
. Do not apply if tem
perature is below 50º F. or above
95º F. Do not thin. B
rush, roll or spray Anvil #1250 U
ltra-Seal #1Elastom
eric Roof C
oating over previously conditioned surfaces. Do
not exceed the recomm
ended coverage rate. Allow
to dry one (1) to two
(2) hours before applying 2nd coat. In the case of gutters and other areassubject to standing w
ater, the first coat should be allowed to dry for a
minim
um of four (4) hours. If application of 2nd coat is postponed for
several days, the surface may need to be cleaned before applying coating.
Apply second coat of A
nvil #1250 Ultra-Seal #1 Elastom
eric Roof
Coating at a recom
mended coverage rate to provide a sm
ooth finish. Ifrainfall leads to standing w
ater within tw
enty-four (24) hours after applicationof the second coat, it w
ill be necessary to sweep clean and dry surface to
minim
ize the possibility of blisters or adhesion failure between coats. If
blisters do occur, they should be cut out and the affected area restored to afull tw
o (2) coat application as described above. In extreme hot, w
indy, ordry conditions w
et surface to be coated with a fine m
ist of clean water just
before applying Anvil #1250 U
ltra-Seal #1 Elastomeric Roof C
oating.C
lean application equipment im
mediately after use w
ith warm
water and
soap.
5 YEA
R W
AR
RA
NT
YA
nvil #1250 Ultra-Seal #1 Elastom
eric Roof Coating is w
arranted tobe free from
manufacturing defects for a period of five (5) years from
the date of purchase when applied according to instructions contained
herein. Should the coating not perform as stated herein during the
warranty period, A
nvil will provide purchaser, upon presentation of
proof of purchase, with replacem
ent coating sufficient to repair theaffected portion of the coating. Failures due to structural defects,acts of G
od, or causes beyond our control are not covered by thisw
arranty.LIM
ITATIO
N O
F LIAB
ILITY
This product is m
anufactured to rigid control specifications. It isim
possible to control the use and application. Therefore, Seller’s
and Manufacturer’s only obligation shall be to replace product
proven to be defective. Proof of purchase is required. Neither
Seller or manufacturer shall be liable for any injury, loss, or
damage, direct or consequential arising from
the use or the abilityto use this product. B
efore using, user shall determine the
suitability of the product for the intended use and user assumes all
risks and liability .
WA
RN
ING
! If you scrape, sand, or remove old paint, you m
ay releaselead dust. LEA
D IS TO
XIC
. EXPO
SUR
E TO LEA
D D
UST C
AN
CA
USE SER
IOU
S ILLNESS, SU
CH
AS B
RA
IN D
AM
AG
E.ESPEC
IALLY
IN C
HILD
REN
. PREG
NA
NT W
OM
EN SH
OU
LDA
LSO AV
OID
EXPO
SUR
E. Wear an N
IOSH
-approved respirator tocontrol lead exposure. C
lean up carefully with a H
EPA vacuum
and aw
et mop. B
efore you start, find out how to protect yourself and your
family by contacting the N
ational Lead Information H
otline at 1-800-424-LEA
D or log on to w
ww
.epa.gov/lead.
VO
C u
nder 61.1 grams/liter
Revised 11-17
Supersedes all prior publications