ultra low nox natural gas water heaters€¦ · title:...

2
Residential Line ULTRA-LOW NOx BURNER – Complies with Southern California SCAQMD 2008 Rule 1121 and Northern California BAAQMD 2009 10ng/J NOx emissions requirements. VAPORSHIELD TECHNOLOGY – Shuts off gas and air supply to heater to prevent prolonged vapor burn in combustion chamber should accidental or unattended ignition of flammable vapors occur outside the water heater. PIEZO IGNITER – Affords push button pilot lighting in lieu of matches. MAINTENANCE FREE – No periodic cleaning of combustion air inlet necessary under normal conditions. STANDARD THERMOCOUPLE – Design provides for use of either factory supplied thermocouple or standard replacement thermocouple. SELF-CLEANING – Turbulence inducing cold water inlet-tube engineered to diminish hard water area sediment deposits. NON-CFC FOAM INSULATED – Saves energy and reduces fuel costs by maximizing heat retention. HIGH EFFICIENCY MODELS – meet energy-efficiency .62 EF (Energy Factor) requirements of many gas utility rebate programs and comply with CEC Title 24. HEAVY GAUGE STEEL TANK – For extra years of trouble-free service. GLASS-LINED TANK – Inner tank glass-lined with Dura-Glas™ and fired at 1600° F for optimum protection from the effects of corrosion. MAGNESIUM ANODE ROD – To protect tank life. FACTORY INSTALLED DIELECTRIC HOT AND COLD WATER CONNECTIONS – 3/4” NPT water connections to extend tank life and for easier installations. BRASS DRAIN VALVE – Durable to prevent unintentional breakage. FACTORY INSTALLED HEAT TRAPS – Reduces standby heat loss in water piping. TEMPERATURE AND PRESSURE RELIEF VALVE – Factory provided T & P Valve can be relocated from side to optional top opening. FACTORY INSTALLED ENERGY CUT-OFF SYSTEM Automatic thermostat with built-in gas pressure regulation also incorporates energy cutoff switch to prevent abnormally high water temperature for added safety. DESIGN CERTIFIED BY CSA INTERNATIONAL – To meet or exceed ANSI requirements and tested in accordance with D.O.E. test procedures and meets or exceeds the energy efficiency requirements of NAECA, ASHRAE and all state energy efficiency standards. CHOICE OF SIX OR TWELVE YEAR LIMITED TANK WAR- RANTIES – Includes 6 or 12 Year Limited Warranty on Component Parts. Available in 30, 40 & 50 Gallon Tall Models and 30, 40, & 50 Gallon Short Models Ultra Low NOx Natural Gas Water Heaters 9/11 www.americanstandardwaterheaters.com 561 New York Drive, Pomona, California 91768 (800) 900-9063 * (909) 392-0230 * FAX (909) 392-7302

Upload: tranthuy

Post on 25-Apr-2018

223 views

Category:

Documents


3 download

TRANSCRIPT

••

••

••

Residential Line

ULTRA-LOW NOx BURNER – Complies with Southern California SCAQMD 2008 Rule 1121 and Northern California BAAQMD 2009 10ng/J NOx emissions requirements.VAPORSHIELD TECHNOLOGY – Shuts off gas and air supply to heater to prevent prolonged vapor burn in combustion chamber should accidental or unattended ignition of flammable vapors occur outside the water heater.PIEZO IGNITER – Affords push button pilot lighting in lieu of matches.MAINTENANCE FREE – No periodic cleaning of combustion air inlet necessary under normal conditions.STANDARD THERMOCOUPLE – Design provides for use of either factory supplied thermocouple or standard replacement thermocouple.SELF-CLEANING – Turbulence inducing cold water inlet-tube engineered to diminish hard water area sediment deposits.NON-CFC FOAM INSULATED – Saves energy and reduces fuel costs by maximizing heat retention.HIGH EFFICIENCY MODELS – meet energy-efficiency .62 EF (Energy Factor) requirements of many gas utility rebate programs and comply with CEC Title 24.HEAVY GAUGE STEEL TANK – For extra years of trouble-free service.GLASS-LINED TANK – Inner tank glass-lined with Dura-Glas™ and fired at 1600° F for optimum protection from the effects of corrosion.MAGNESIUM ANODE ROD – To protect tank life.FACTORY INSTALLED DIELECTRIC HOT AND COLD WATER CONNECTIONS – 3/4” NPT water connections to extend tank life and for easier installations.BRASS DRAIN VALVE – Durable to prevent unintentional breakage.FACTORY INSTALLED HEAT TRAPS – Reduces standby heat loss in water piping.TEMPERATURE AND PRESSURE RELIEF VALVE – Factory provided T & P Valve can be relocated from side to optional top opening.FACTORY INSTALLED ENERGY CUT-OFF SYSTEM – Automatic thermostat with built-in gas pressure regulation also incorporates energy cutoff switch to prevent abnormally high water temperature for added safety.DESIGN CERTIFIED BY CSA INTERNATIONAL – To meet or exceed ANSI requirements and tested in accordance with D.O.E. test procedures and meets or exceeds the energy efficiency requirements of NAECA, ASHRAE and all state energy efficiency standards.CHOICE OF SIX OR TWELVE YEAR LIMITED TANK WAR-RANTIES – Includes 6 or 12 Year Limited Warranty on Component Parts.

Available in 30, 40 & 50 Gallon Tall Models and 30, 40, & 50 Gallon

Short Models

Ultra Low NOx Natural Gas Water Heaters

9/11

www.americanstandardwaterheaters.com

561 New York Drive, Pomona, California 91768(800) 900-9063 * (909) 392-0230 * FAX (909) 392-7302

A

BF

ED

C

G

SPECIFICATIONS AND APPLICATION DATA

• For 12 year models, change the model number rom“6” to “12”. Example: G-40T-1-3-12

• All models meet SCAQMD 2008 Rule 1121 and Nor thernCalifornia BAAQMD 2009 10ng/J NOx emissionsrequirements.

• All models comply with NAECA requirements and are CEClisted.

• Recovery capacity based on actual performance tests.

• All models are cer at 300 PSI test pressure and 150 PSIworking pressure.

• Dimensions change withoutnotice in accordance with our policy of continuous productimprovement.

For floor to optional Top T & P Outlet see dimension “C”

MODELNUMBER

TALLG-30T-1-3-6G-30T-2-3-6G-40T-1-3-6G-50T-1-3-6G-50T-1-4-6G-50T-2-4-6

G-40T-2-3-6G-50T-2-3-6

G-30L-1-3-6G-40L-1-3-6G-40L-2-3-6G-50L-1-3-6

GALLONCAPACITY

303040505050

4050

30404050

FIRSTHOUR

RATINGGALLONS

565661736868

7180

55575773

BTUINPUTNATGAS

35,00035,00040,00040,00048,00048,000

40,00040,000

35,00037,00037,00040,000

GPHREC

AT 90o

RISE383843435252

4343

38404043

ENERGYFACTOR

.61

.61

.60

.58

.58

.58

.62

.62

.61

.60

.61

.59

RFACTOR

816888

16

1616

88

168

VENTDIAM

A333344

33

3333

JACKETDIAM

B16 1/418 1/418 1/420 1/420 1/422 1/4

20 1/422 1/4

18 1/420 1/422 1/422 1/4

TOP OFHEATER

C58 3/858 3/858 1/257 1/857 1/857 1/8

58 1/257 1/8

46 3/448 1/248 1/249 1/2

TOPWATER

D59 1/259 1/259 3/458 3/858 3/858 3/8

59 3/458 3/8

48 1/250 1/450 1/4

51

SIDET & P

E5353

52 3/4515151

52 3/451

4142 3/842 3/842 3/4

TOP OFVENT

F61 1/461 1/461 1/260 1/860 1/860 1/8

61 1/260 1/8

49 3/451 1/251 1/252 1/4

WATER SPREAD

G888888

88

8888

APROXSHIP WGT

(LBS)129 60135147163164174

153173

127154164200

DIMENSIONS IN INCHESHEIGHT TO

HIGHEFFICIENCY

SHORTLOWBOY

Recovery capacity based on actual performance tests.

SAMPLE SPECIFICATION

Water heater shall be AMERICAN STANDARD model _____________ having a storage capacity of ________

gallons, operate on Natural Gas with a BTU input of _____________ and a recovery rate of ________ gallons

per hour at 90° F temperature rise. Water heater tank interior shall be glass lined with Dura-Glas™, furnished

with anode rod and insulation shall be non-CFC foam. Water heater shall be CSA certified.

9/11

www.americanstandardwaterheaters.com