uk/ireland - accuray exchange · 2018. 5. 8. · uk/ireland users’ meeting breakout room 2 -...

3
UK/Ireland Users’ Meeting FRIDAY, JUNE 8 th , 2018 10:00 – 17:00 LONDON 10:00 30 mins Registration & Welcome Coffee Networking All Attendees 10:30 10 mins Accuray Welcome Accuray Dirk Freynhagen 10:40 30 mins The Future at Accuray: a Roadmap Accuray Ludovic Peyre Susan Reid 11:10 20 mins Multiple Sites of SBRT Treated Alongside Primary Lung Cancer: A Case Study Royal Marsden Hospital Helen Taylor Lead CyberKnife Radiographer 11:30 20 mins Clinical Experience of Stereotactic Ablative Body Radiation Therapy for the treatment of Oligometastases Originating from Lower Gastrointestinal Primary Malignancies Mount Vernon Cancer Centre Julie Duong GI Advanced Practitioner Radiographer 11:50 20 mins National Physical Laboratory (NPL) Collaborative Research & Development Consortium National Physical Laboratory Russ Thomas 12:10 60 mins Networking Lunch 13:10 3.10 hrs Breakout Sessions TomoTherapy® System & CyberKnife® System 16:20 10 mins Reconvene in Joint Session 16:30 15 mins Accuray Closing Remarks & Event Survey 16:45 Meeting Close and Departures 2018 UK & Ireland Users’ Meeting Preliminary Programme #ACCURAYPATIENTFIRST

Upload: others

Post on 19-Aug-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: UK/Ireland - Accuray Exchange · 2018. 5. 8. · UK/Ireland Users’ Meeting BREAKOUT ROOM 2 - RADIXACT® & TOMOTHERAPY® SYSTEMS 13:10 20 mins Current UK TomoTherapy ® System QA

UK/Ireland Users’ Meeting

FRIDAY, JUNE 8th, 2018 • 10:00 – 17:00 • LONDON

10:00 30 mins Registration & Welcome Coffee Networking All Attendees

10:30 10 mins Accuray Welcome Accuray Dirk Freynhagen

10:40 30 mins The Future at Accuray: a Roadmap Accuray Ludovic Peyre Susan Reid

11:10 20 mins Multiple Sites of SBRT Treated Alongside Primary Lung Cancer: A Case Study

Royal Marsden Hospital

Helen TaylorLead CyberKnife Radiographer

11:30 20 mins Clinical Experience of Stereotactic Ablative Body Radiation Therapy for the treatment of Oligometastases Originating from Lower Gastrointestinal Primary Malignancies

Mount Vernon Cancer Centre

Julie Duong GI Advanced Practitioner Radiographer

11:50 20 mins National Physical Laboratory (NPL) Collaborative Research & Development Consortium

National Physical Laboratory

Russ Thomas

12:10 60 mins Networking Lunch

13:10 3.10 hrs Breakout Sessions TomoTherapy® System & CyberKnife® System

16:20 10 mins Reconvene in Joint Session

16:30 15 mins Accuray Closing Remarks & Event Survey

16:45 Meeting Close and Departures

2018 UK & Ireland Users’ Meeting Preliminary Programme

#ACCURAYPATIENTFIRST

Page 2: UK/Ireland - Accuray Exchange · 2018. 5. 8. · UK/Ireland Users’ Meeting BREAKOUT ROOM 2 - RADIXACT® & TOMOTHERAPY® SYSTEMS 13:10 20 mins Current UK TomoTherapy ® System QA

UK/Ireland Users’ Meeting

BREAKOUT ROOM 1 - CYBERKNIFE® SYSTEM

13:10 20 mins Stereotactic Radiation Therapy for Uveal Melanoma Patients on the CyberKnife® System

Erasmus MC Cancer Institute

Lisette KlopRadiation Therapy Technician

13:30 20 mins Using Bragg Peak Chamber for IRIS QA The London Clinic Jan KonieczekSenior Medical Physicist

13:50 20 mins Investigation of the impact of Planning Target Volume (PTV) Density on Dose Coverage for Stereotactic Ablative Body Adiotherapy (SABR) Lung Plans

Mount Vernon Cancer Centre

PrasanasarathyNariyangaduRadiotherapy Physicist

14:10 20 mins Online-Adaptive Stereotactic Radiotherapy for Abdominopelvic Lymphnode Oligometastases

Erasmus MC Cancer Institute

Willem den ToomSenior Radiographer, RTT

14:30 30 mins Tea Break

15:00 20 mins CyberKnife® System Planning for Prostate Patients with Prosthetic Hips: Planning Strategy and Comparison with IMRT/VMAT

Royal Marsden NHS Foundation Trust

Philippa SturtPrincipal Physicist – Stereotactic/CtE

15:20 20 mins How Low Can You Go: What is the Smallest Lung Lesion We Can Treat Accurately with CyberKnife® System?

Barts Health NHS Trust Chris Dean Stereotactic Lead Physicist

15:40 20 mins Comparison of Raytracing and Monte Carlo Dose Calculation Algorithms in CyberKnife® System Treatment for Pituitary Adenoma Radiation Treatment Planning

Hermitage Medical Clinic Ismail Ahmed

16:00 20 mins CyberKnife® System Group Discussion All

16:20 End of the Session and Return to Main Session All

#ACCURAYPATIENTFIRST

Page 3: UK/Ireland - Accuray Exchange · 2018. 5. 8. · UK/Ireland Users’ Meeting BREAKOUT ROOM 2 - RADIXACT® & TOMOTHERAPY® SYSTEMS 13:10 20 mins Current UK TomoTherapy ® System QA

UK/Ireland Users’ Meeting

BREAKOUT ROOM 2 - RADIXACT® & TOMOTHERAPY® SYSTEMS

13:10 20 mins Current UK TomoTherapy® System QA Practice Brighton & Sussex University Hospitals

Thomas O’BrienTrainee Clinical Scientist

13:30 20 mins Clinical Implementation of the Radixact® System: A Radiographer Perspective

Addenbrooke Hospital Cristina Ferreira Team Lead Radiographer – Radixact®

Carly Jones Senior Radiographer – Radixact®

13:50 20 mins 3D Water Scanning Evaluation for Helical Beam Data

BUPA Cromwell Hospital

Ana LuisPrincipal Physicist

14:10 20 mins The use of the independent dose calculation software Check Tomo® to check TomoEDGE™ plans.

Addenbrooke’s Hospital

Simon Thomas Physicist

14:30 30 mins Tea Break

15:00 20 mins TomoTherapy® IMRT in the Management of Extremity Soft Tissue Sarcomas at the Northern Centre for Cancer Care, Freeman Hospital – 8 years’ experience

Northern Centre for Cancer Care, Freeman Hospital

Jayshree VeeratterapillayClinical Oncology SpR

15:20 20 mins On the Measurements of MLC Relative Leaf Opening Times for Quality Control

Queen Elizabeth Hospital, University Hospital Birmingham NHS Trust

Lawal KadiriPhysicist

15:40 20 mins Working with a Solo TomoTherapy® Machine Nottingham Radiotherapy Department

Peter Wakelin Superintendent Radiographer

Louis Roberts

16:00 20 mins TomoTherapy® System Group Discussion All

16:20 End of the Session and Return to Main Session All

#ACCURAYPATIENTFIRST