ucs 1.4 direct connect storage 3.2.pptx [read-only] · support for netapp and emc direct attached...
TRANSCRIPT
© 2006 Cisco Systems, Inc. All rights reserved. Cisco Highly Confidential – Controlled AccessUCS TAB 1
UCS 1.4 Direct Connect Storage Guide v3.2
© 2006 Cisco Systems, Inc. All rights reserved. Cisco Highly Confidential – Controlled AccessUCS TAB 2
Topics
� New Topologies and Features Overview
� New Storage Port Types Behavior Examined
� Details on FC and FCoE Direct Connect Implementation
� Appliance ports (NAS Direct Connect)
� Details on new Storage and Appliance Clouds and scope of objects
Links, VLANs, VSANs
� iSCSI Boot Status and Roadmap
� Interoperability with Storage and UCS Resources
© 2006 Cisco Systems, Inc. All rights reserved. Cisco Highly Confidential – Controlled AccessUCS TAB 3
Exec Summary: UCS 1.4 Storage Features
� New Direct Connect Topologies introduced
Allows lower cost point for small UCS Pod like deployments
Remote Location scenarios
Migration from FC to FCoE Use Case
� FC Port Channeling and VSAN Trunking
More flexibility in engineering FC traffic vs. 1 VSAN per uplink
Catch-up with N5K “expected” feature set
Requires MDS or N5K to Work (both features)
© 2006 Cisco Systems, Inc. All rights reserved. Cisco Highly Confidential – Controlled AccessUCS TAB 4
Feature Overview
© 2006 Cisco Systems, Inc. All rights reserved. Cisco Highly Confidential – Controlled AccessUCS TAB 5
� Support for NetApp and EMC direct attached storage
� Ability to turn On/Off Fibre Channel switching mode
� Zoning configuration not supported, but zoning may be inherited from upstream switch
� Default zoning available, no access by default (details discussed later)
� Ethernet and FC switching modes are independent
� Note: No management integration with FC Storage layer
� Support to directly connect FC/ FCoE storage to 6100
� End to end FCoE topologies possible� Lower cost point for small deployments (no access
layer FC switches)
Customer benefits
Feature details
UCS B-Series
UCS 6100 UCS 6100
FCoE Storage FC Storage
1.4 Release Feature Preview
Enable Direct Connection of FC Storage
© 2006 Cisco Systems, Inc. All rights reserved. Cisco Highly Confidential – Controlled AccessUCS TAB 6
Key Considerations of FC Direct Connect.
� No FC Zoning without upstream connection to MDS or N5K
Upstream MDS/N5K allows zoneset merges but no zoning configuration exposed on UCS Software.
Without zoneset merge only security is using LUN Mapping on the array
Typically ok for smaller homogeneous (OS) deployments
LUN masking has a long history and in use today already but not as sole security measure in most environments.
� External SAN Management Software
N5K MIBs are all exposed but READ ONLY
6100 can be added to Fabric Manager (FM) but the manageability through FM is limited
© 2006 Cisco Systems, Inc. All rights reserved. Cisco Highly Confidential – Controlled AccessUCS TAB 7
� Support for NAS (Ethernet appliance) in End Host (general best practice) without putting 6100 in switch mode
� New “Appliance port” to support this functionality.
� Provides Ethernet connectivity in End Host Mode to a third party appliance
� Note: No management integration with storage filer
� Supported advanced configuration on Appliance ports:
� Port Mode – Access or Trunk
� Specify allowed VLAN
� Pin-group configuration - Static or Dynamic
� QOS policy
� Static Mac Address
� Storage appliance (NAS) to be connected to Fabric interconnects in “END HOST” Mode
� Eliminates additional access-layer switches and hops
Customer benefits
Feature details
UCS B-Series
Switch Mode
NAS Appliance
UCS B-Series
End Host
NAS Appliance
UCS 1.4
Current
NAS port
uplink Port
1.4 Release Feature Preview
Enable Direct Connection of NAS Appliances
© 2006 Cisco Systems, Inc. All rights reserved. Cisco Highly Confidential – Controlled AccessUCS TAB 8
� vHBAs can be on different VSANs
� Uplink FC ports will be in NPV mode (N-Port) by default
� All VSANs will be trunked on every uplink FC port
Selecting a subset of VSANs for individual uplink ports not supported
� Scalability: Max of 32 VSANs per UCS system
� VSAN trunking supported in FC switch mode as well
� VSAN Trunking is not available for direct connect FC (or FCoE) Storage Port types
� Provide isolation to SAN traffic over the same physical FC link
� Help consolidate FC infrastructure
Customer benefits
Feature details
SAN A SAN B
vFCs
VSAN A
VSAN B
VSAN C
VSAN D
FC Port Trunking (Multiple VSANs per Link)
© 2006 Cisco Systems, Inc. All rights reserved. Cisco Highly Confidential – Controlled AccessUCS TAB 9
� Up to 16 FC ports can be aggregated together for a single port channel
� Different combination of FC ports from different expansion modules on the FI can be placed on the same port channel
� In case of port speed mis match – port channel forces port speed to highest commonly supported speed
� VSANs can be trunked over the port channel
� VSAN trunking and port channel supported for both NPV and switch mode FI operation
� FC Port channeling is not available for direct connect FC Storage Port types
� Aggregate and maximize available bandwidth while maintaining isolation
� Increases resiliency and guard against port failures
Customer benefits
Feature details
SAN A SAN B
vFCs
VSAN A
VSAN B
VSAN C
VSAN D
ISL Port Channel
1.4 Release Feature Preview
FC Port Channels
© 2006 Cisco Systems, Inc. All rights reserved. Cisco Highly Confidential – Controlled AccessUCS TAB 10
New Port Types Behavior and Management View
New Port Types and When they are Valid
© 2006 Cisco Systems, Inc. All rights reserved. Cisco Highly Confidential – Controlled AccessUCS TAB 11
UCS 1.4 and Direct Connect Storage
� Concept is to eliminate need for access layer FC or Ethernet switch for connecting UCS 6120/40 to Storage.
� Fabric Interconnect can operate in different modes that are independent of each other
FC Switching
Ethernet Switching
� Three New Port types in UCS 1.4 related to the new capability
Storage FC Port
Storage FCoE Port
Appliance Port (allows direct connect NAS without putting FI into switch mode)
© 2006 Cisco Systems, Inc. All rights reserved. Cisco Highly Confidential – Controlled AccessUCS TAB 12
UCS Manager View of New Ports
© 2006 Cisco Systems, Inc. All rights reserved. Cisco Highly Confidential – Controlled AccessUCS TAB 13
Port Types vs. FI Operating Mode (green means valid in mode of operation)
© 2006 Cisco Systems, Inc. All rights reserved. Cisco Highly Confidential – Controlled AccessUCS TAB 14
Functional Role of Ports (External View)
© 2006 Cisco Systems, Inc. All rights reserved. Cisco Highly Confidential – Controlled AccessUCS TAB 15
Describing the New Port Types (Implementation details covered in later slides)
� FCoE Storage Ports
Ethernet port with vfc bound
No additional controls provided
� Appliance Ports (NAS = iSCSI, CIFS or NFS)
Act like server ports
Normal MAC-learning (EHM Uplink Ports MACs are not learned)
Trunk allowed VLAN(s), Native VLAN (optional)
QoS Policy on Interface (optional)
Interface speed (1G/10G with normal port rules)
Static Pin-Group or allow default dynamic
© 2006 Cisco Systems, Inc. All rights reserved. Cisco Highly Confidential – Controlled AccessUCS TAB 16
Supported Topologies at GA
Direct Connect and Hybrid
© 2006 Cisco Systems, Inc. All rights reserved. Cisco Highly Confidential – Controlled AccessUCS TAB 17
Direct Storage Only Topology
UCS B-Series
UCS 6100 UCS 6100
FCoE Storage FC Storage
Fibre Channel
Ethernet
Unified I/O
FCoE
� Security
ONLY via LUN Masking
iGroup – NetApp
Storage Group – EMC
� No FC Zoning
Default zoning must be enabled per VSAN
� No Domain ID config
� Limited Number of initiators and targets
See Docs for Values
© 2006 Cisco Systems, Inc. All rights reserved. Cisco Highly Confidential – Controlled AccessUCS TAB 18
Hybrid Topology with direct-attach and SAN
UCS B-Series
UCS 6100 UCS 6100
FCoE StorageFC Storage
Fibre Channel
Ethernet
Unified I/O
FCoE
Core
Fabric A Fabric B
SAN Fabric Storage Arrays
SAN Edge A SAN Edge B
Direct Attach
� Security via Zoneset Merge
AND
� Security via LUN Masking
� LUN masking always used tosome extent
© 2006 Cisco Systems, Inc. All rights reserved. Cisco Highly Confidential – Controlled AccessUCS TAB 19
Unsupported Storage Topologies in UCS 1.4
� Multi-Hop FCoE or FCoE “northbound” on Ethernet Uplinks
This is planned for 2012 Release
6100 to N5K for FC to FCoE bridging is still valid with 1.4 in NPV mode
� FC connections between the two Fabric Interconnects running in FC switch mode (ISL)
� Connecting any other L2 based object off of the Appliance Ports
Untested, unsupported until further notice
© 2006 Cisco Systems, Inc. All rights reserved. Cisco Highly Confidential – Controlled AccessUCS TAB 20
Configuration Details
How to Establish Connectivity With Your Storage
© 2006 Cisco Systems, Inc. All rights reserved. Cisco Highly Confidential – Controlled AccessUCS TAB 21
Overview of the Operational Flow for FC Direct Connect(Getting it Up and Running)
1. Put the Fabric Interconnects into FC Switching Mode
Note: This will reboot both Fabric Interconnects and cause system wide downtime for 10-15 minutes.
2. Configure your FC Storage Ports (direct connect)
3. Enable Access to the default zones per VSAN
4. Configure the right VSAN per FC Storage Port
© 2006 Cisco Systems, Inc. All rights reserved. Cisco Highly Confidential – Controlled AccessUCS TAB 22
Upgrading from Prior UCS Releases
� Pre-1.4 Required Upstream FC Switch to be in NPIV Mode.
� If you upgrade from 1.x to 1.4 and place the 6100s into FC switching mode and you still have an upstream FC switch connected, it will have to be placed back into E mode.
� Summary
If running in FC end-host mode (NPV mode), the port-mode on the upstream switches need to be in F mode
If running in FC switching mode (non-NPV mode), the port-mode on the upstream switches need to be in E mode
© 2006 Cisco Systems, Inc. All rights reserved. Cisco Highly Confidential – Controlled AccessUCS TAB 23
How to Place FI into FC Switching Mode
• This operation results in both FIs going into reboot
cycles which takes 15 min or so, system wide downtime, by design
• When FC switch mode is
turned on, all the FC ports
come up in TE mode
© 2006 Cisco Systems, Inc. All rights reserved. Cisco Highly Confidential – Controlled AccessUCS TAB 24
Configuring an FC storage port
• To connect an FC storage device directly into one of the 6100’s FC port, the user must configure the port as an FC storage port.
• Internally, the port is configured as follows:
As a F_Port
As an access port
The speed is kept as auto
The user is also allowed to select a named VSAN for that port.
© 2006 Cisco Systems, Inc. All rights reserved. Cisco Highly Confidential – Controlled AccessUCS TAB 25
Configuring an FC storage port (GUI)
© 2006 Cisco Systems, Inc. All rights reserved. Cisco Highly Confidential – Controlled AccessUCS TAB 26
You Must Enable Default Zoning per VSAN
� Default Zoning is not enabled by default
� SJ2-151-B26-A# scope fc-storage
� SJ2-151-B26-A /fc-storage # scope vsan default
� SJ2-151-B26-A /fc-storage/vsan # set default-zoning enabled
� SJ2-151-B26-A /fc-storage/vsan # commit-buffer
© 2006 Cisco Systems, Inc. All rights reserved. Cisco Highly Confidential – Controlled AccessUCS TAB 27
Configuring a VSAN on a FC port (GUI)