uc santa cruz standard plaster installation and …...lath & plaster installation sequence guide...
TRANSCRIPT
![Page 1: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/1.jpg)
CAMPUS STANDARDS APPENDIX H
UC SANTA CRUZ
STANDARD PLASTER INSTALLATION AND DETAILS
STANDARD
December 5, 2014
![Page 2: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/2.jpg)
Window Installation Sequencing Guide
Pyatok Architects and Allana Buick & Bers Inc.
12/5/2014
NOTES:
1. Any conditions that do not allow the installation to be performed as outlined in
this guide require notification of the Architect.
2. Where elements on details and instruction are noted to be “soldered”, elements
are to be “soldered water-tight”, not just “spot” of “tack” soldered.
![Page 3: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/3.jpg)
Page 1 of 12
Window Sill Detail (Detail 1/A9.01)
The rough opening is prepared by applying the primer on all sheathing surfaces to receive SAF.
![Page 4: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/4.jpg)
Page 2 of 12
ALL SAF installed to roll flat with J-Roller.
Sheathing to receive SAF with gaps greater than 1/8” to be treated with sealant to provide backing.
![Page 5: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/5.jpg)
Page 3 of 12
Sealant being applied in sheathing gap greater than 1/8”
SAF corner pieces installed at bottom corners 4” up jambs.
![Page 6: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/6.jpg)
Page 4 of 12
GSM angle with 3/4” vertical leg butted up to tapered shim at sill, secured with “S.S. Pan-Head screws” or “hot-dip galvanized ring-shanks nails” into sill framing.
SAF butterfly patches installed at sill GSM angle to jamb intersections. Cut SAF at dotted line to lay flat on wall face. Release paper to remain.
![Page 7: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/7.jpg)
Page 5 of 12
12” wide SAF installed min. 4” over sheathing face, onto the GSM angle to interior edge of sill R.O. Note: SAF w/ release paper still attached at horizontal surface OR install strip of WRB below all wall openings prior to SAF installation.
SAF butterflies installed at outside framing corners of sill.
![Page 8: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/8.jpg)
Page 6 of 12
Window Jamb Detail (Detail 2/A9.01)
12” wide SAF installed along jamb over sheathing face 4” and extending 4” beyond rough opening @ top & bottom.
![Page 9: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/9.jpg)
Page 7 of 12
SAF butterfly patches installed at jamb to head framing outside corners. NOTE: Photo is from Phase 1 Mockup. Ignore SAF type and green Air and Water Barrier.
Window Head Detail (Detail 3/A9.01)
![Page 10: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/10.jpg)
Page 8 of 12
9” wide SAF installed over window head and extended to outside edge of jamb SAF.
Apply continuous bead of Silicone or Moistop sealant at window head and jamb sides. Sill to be wet set into sealant, between interior face of window frame and GSM angle. Note: Do not apply sealant along sill nailing flange.
![Page 11: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/11.jpg)
Page 9 of 12
Window installed into rough opening into continuous bead of sealant along head and jambs. Fasten with “S.S. Pan-Head Screws”. Note: Do not nail/screw thru window flange at along head.
1/16 inch plastic shims installed along sill flange, do not extend past window frame width.
![Page 12: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/12.jpg)
Page 10 of 12
9” wide SAF installed over window flange jambs, extended 6” beyond sill & head rough openings
9” wide SAF installed over window head, extended to outside edge of jamb SAF.
![Page 13: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/13.jpg)
Page 11 of 12
GSM head flashing installed over window head. Fasten using “hot-dip galvanized ring-shank nails”. Do not penetrate window head fin with fasteners.
12” wide SAF installed over GSM head flashing.
![Page 14: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/14.jpg)
Page 12 of 12
Install GSM angles along jambs, set in a full-bed of sealant. Also apply sealant between joint of GSM angle and window frame. (Interior Side)
![Page 15: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/15.jpg)
Door Installation Sequencing Guide
Pyatok Architects and Allana Buick & Bers, Inc.
12/5/2014
Notes:
1. Details and photos show an out-swinging door. Sequencing is identical for in-swinging doors.
2. Any conditions that do not allow the installation to be performed as outlined in this guide require immediate notification of the Architect.
3. Where elements on details and instructions are noted to be “soldered”. Elements are to be “soldered water-tight”, not just “spot” or “tack” soldered.
![Page 16: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/16.jpg)
Page 1 of 8
Exterior Door Threshold @ Landing
(Detail 6/A9.10)
The rough opening is prepared by applying
the primer on all sheathing surfaces to
receive SAF.
![Page 17: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/17.jpg)
Page 2 of 8
Sealant applied along door sill and wall
flanges for sill pan installation.
Fully soldered GSM sill pan set in full bed of sealant under sill and wall flanges. Slide pan into opening to smear sealant and eliminate air pockets. Apply hot-dip galvanized ring-shank nail fasteners through vertical surfaces only.
![Page 18: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/18.jpg)
Page 3 of 8
Confirm podium waterproofing installed onto door sill pan and up jambs prior to door frame installation. NOTE: Protection board over hot rubber not shown in this photo.
ALL SAF installed to roll flat with J-Roller.
![Page 19: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/19.jpg)
Page 4 of 8
12” wide SAF installed into full depth of rough opening extending out over sheathing 4” min.
Exterior Door Jamb (Detail 7/A9.10)
![Page 20: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/20.jpg)
Page 5 of 8
Remove flange from bottom corners of door frame jambs prior to setting into rough opening.
Door frame set into rough opening and secured to structure with “stainless steel pan-head screws” or “hot-dip galvanized
ring-shank nails.
![Page 21: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/21.jpg)
Page 6 of 8
24 GA GSM L-Metal installed, with minimum 1/4” contact between L-Metal and Door Frame, set in sealant. Note: UV metal at base of wall at deck to be installed after L-Metal.
L-metal interlocking leg trimmed at base of door jambs to accommodate base flashing waterproofing build-up.
![Page 22: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/22.jpg)
Page 7 of 8
6” wide SAF installed over L-Metal and under plaster stop.
Exterior Door Head (Detail 8/A9.10)
![Page 23: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/23.jpg)
Page 8 of 8
GSM head flashing installed, head flashing to overhang over door frame.
9” wide SAF installed over window head flashing.
![Page 24: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/24.jpg)
Landing Waterproofing Installation Sequencing
Guide
Pyatok Architects and Allana Buick & Bers, Inc.
12/5/2014
Notes:
1. Any conditions that do not allow the installation to be performed as outlined in this guide require immediate notification of the Architect.
2. Where elements on details and instructions are noted to be “soldered”. Elements are to be “soldered water-tight”, not just “spot” or “tack” soldered.
![Page 25: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/25.jpg)
Page 1 of 16
Prior to installation of podium WP confirm
preceding installations complete (i.e. sheet
metal saddles, door sill pans, continuous wall
flashing, etc).
Note: All sheet metal flashings to receive
WP membrane to be set in manufacturer approved sealant.
Clean the substrate(s) to receive podium
waterproofing before proceeding with
application of podium WP system.
NOTE: Photo is from
Phase 1 Mockup. Ignore GSM wall base flashing and green Air
and Water Barrier.
![Page 26: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/26.jpg)
Page 2 of 16
PRIMER is to be applied using a hand
held sprayer onto ALL surfaces receiving the
podium WP membrane.
Typical Podium WP @ Wall
(Detail 9/A8.22)
![Page 27: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/27.jpg)
Page 3 of 16
1st Coat of podium waterproofing applied
(approx. 90 mils).
NOTE: Neoprene @ deck edge applied beforehand. Deck
edge waterproofing installation described
on pages 4-7
Uncured neoprene set into 1st coat of WP membrane at wall
base.
![Page 28: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/28.jpg)
Page 4 of 16
Following the application of 1st coat of the WP membrane
install the uncured neoprene onto the
door sill pan.
NOTE: Neoprene may be replaced w/
Reemay reinforcing fabric on faces of door rough opening to avoid
build-up
Typical Podium WP @ Deck Edge
(Detail 8/A8.22)
![Page 29: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/29.jpg)
Page 5 of 16
Apply 1st coat of WP onto deck edge
Set 9” wide uncured neoprene onto
horizontal surface of edge allowing min 3”
of neoprene onto vertical surface.
![Page 30: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/30.jpg)
Page 6 of 16
Apply a bonding adhesive (sealant)
onto the vertical surface of the deck edge to receive the uncured neoprene
Note: Amount and pattern of bonding adhesive sealant
application shown in photo not acceptable.
Alternative uncured neoprene outside corner options in lieu of “pig ear” to be explored. Note: Application as shown in photo not acceptable. Diagram below shows acceptable corner lapping method. Dotted lines are deck edge.
![Page 31: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/31.jpg)
Page 7 of 16
Apply WP membrane onto uncured neoprene over deck edge.
Set 22 GA S.S. edge metal into WP
membrane, fastened @ 4” o.c., 2-rows
staggered.
Note: Clean and Apply Primer onto S.S. edge metal on surfaces to come in contact with WP membrane (top
and bottom surfaces of horizontal leg).
![Page 32: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/32.jpg)
Page 8 of 16
Pipe penetration WP @ Deck
(Detail 11/AC8.22)
2-piece S.S. pipe collar, with hemmed top edge secured to
deck w/ fasteners and sealant
![Page 33: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/33.jpg)
Page 9 of 16
Primer applied onto S.S. pipe collar prior to
WP membrane application.
1st coat of WP membrane applied onto flange of S.S.
pipe collar.
![Page 34: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/34.jpg)
Page 10 of 16
2-pieces of uncured neoprene
reinforcement with WP membrane between laps applied around
S.S. pipe collar, extending beyond nailing flange onto
horizontal deck.
NOTE: Neoprene may be replaced w/
Reemay reinforcing fabric to avoid build-up
2nd coat of WP membrane applied
onto uncured neoprene around pipe
collar.
![Page 35: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/35.jpg)
Page 11 of 16
Flashing @ Deck Column
(Detail 6/AP8.22)
Column kerf cut location to be
determined by topping slab height. Existing may be acceptable. Extend cut around entire perimeter of
column.
![Page 36: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/36.jpg)
Page 12 of 16
Deck edge uncured neoprene turned up
base of column underneath kerf cut.
Note: Neoprene
(including vertical leg) to be set in WP
membrane.
2nd coat of WP membrane applied
onto uncured neoprene.
![Page 37: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/37.jpg)
Page 13 of 16
Deck Column Flashing Details
Fully soldered deck edge metal flashing
wrapping around deck column.
Fasten along top edge of flashing.
![Page 38: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/38.jpg)
Page 14 of 16
Full WP membrane system applied over
deck edge metal flashing.
Field application of Podium WP
Following completion of WP detailing (i.e. base flashings, deck edges, saddles, etc.)
Apply 1st Coat of
podium waterproofing (min. 90 mils) with
reinforcing fabric set into membrane.
![Page 39: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/39.jpg)
Page 15 of 16
2nd Coat of podium waterproofing applied (min. 125 mils) onto
reinforcing fabric
Note: Feather podium WP at door jambs and
sheathing face area for door frame to prevent build-up
Apply protection course over 2nd Coat
of podium WP., including onto the sill of door rough
opening.
Note: For critical build-up areas only provide 1-layer of protection
coarse (i.e. door jambs, lath
accessories, etc)
IMPORTANT: Perform
Manufacturer’s required testing prior
to installations of drain mat & concrete
overburden
![Page 40: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/40.jpg)
Page 16 of 16
Install UV metal counter flashing with
hemmed edge on bottom of leg and
fasten with “stainless steel pan-head
screws” or “hot-dip galvanized nails”.
![Page 41: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/41.jpg)
Lath & Plaster Installation Sequence Guide
Pyatok Architects and Allana Buick & Bers, Inc.
12/5/2014
Notes:
1. Any conditions that do not allow the installation to be performed as outlined in this guide require immediate notification of the Architect.
2. Where elements on details and instructions are noted to be “soldered”. Elements are to be “soldered water-tight”, not just “spot” or “tack” soldered.
![Page 42: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/42.jpg)
Page 1 of 30
Base of Wall (Detail 6/A8.02)
Install GSM weep screed at base of wall onto substrate with “S. S. Pan-Head screws” or “hot-dip galvanized
nails”.
![Page 43: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/43.jpg)
Page 2 of 30
ALL SAF installed to roll flat with J-Roller.
Install 9” wide SAF
lapped over top leg of GSM weep screed.
Note: Lap SAF edges
3” min at seams.
![Page 44: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/44.jpg)
Page 3 of 30
Install WRB in shingled fashion integrating into opening and
penetration flashings.
Note: Lap WRB seams horizontally 6” min. and vertically 4”
min.
Scaffolding Bolt WP (Detail 3/A8.01)
![Page 45: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/45.jpg)
Page 4 of 30
Install starter strip of WRB at sill of tie-bolt to allow for shingling
of WRB field installation.
(Step 1)
Note: Tie-back bolt to be proud of sheathing.
Apply SAF “sill” at bolt over WRB starter strip
and sheathing. (Step 2)
![Page 46: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/46.jpg)
Page 5 of 30
Apply second piece of SAF “head” at bolt,
(Step 3)
Apply sealant all around bolt
(Step 4)
![Page 47: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/47.jpg)
Page 6 of 30
Electrical Wall Penetration
(Detail 8/A8.02)
Install starter strip of WRB at sill and
secure fully soldered GSM collar around electrical box with “S.S. Pan-Head
screws” or “hot-dip galvanized nails” as
required.
![Page 48: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/48.jpg)
Page 7 of 30
Install 9” wide SAF along jamb flanges of electrical box flashing
Apply SAF along top flange of electrical box
flashing.
![Page 49: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/49.jpg)
Page 8 of 30
Fabricated Penetration Flashing
(Detail 13/A8.01)
Install SAF along sill of pipe penetration with release paper
remaining on bottom half of SAF or provide starter strip of WRB
prior to SAF installation.
NOTE: Cut and fit SAF tight around
penetration and seal around penetration,
per detail.
![Page 50: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/50.jpg)
Page 9 of 30
Install SAF along head of pipe penetration,
overlapping sill SAF 3” min.
Install 2-piece pipe collar flashing, with 4” min. lap set in a full bed of sealant and
secured to substrate with “S.S. Pan-Head screws” or “hot-dip galvanized nails” as
required. Solder together 2-piece collar after
installing around pipe.
Note: Provide 1/2” min. b/w pipe and
collar for backer rod & sealant.
![Page 51: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/51.jpg)
Page 10 of 30
NO PHOTO
Step 1: Install 6” min. wide SAF along sides of pipe collar flange.
Step 2: Install 6” min. wide SAF along top
flange.
Step 3: Fill joint with backer-rod and
sealant
Wall Opening Flashing Sequence
Diagram (For Openings other than
Windows/Doors)
![Page 52: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/52.jpg)
Page 11 of 30
Make-Up Air Wall Cap Termination (Detail 7/A9.02)
Install SAF along sill of wall cap opening with release paper
remaining on bottom half of SAF or provide starter strip of WRB
prior to SAF installation.
![Page 53: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/53.jpg)
Page 12 of 30
Install SAF along sill and wrapped into sill
of wall cap R.O.
Install SAF along jambs and wrapped
into jambs of wall cap R.O.
Note: Lap seams of
SAF 3” min.
![Page 54: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/54.jpg)
Page 13 of 30
Install SAF along head and wrapped
into jambs of wall cap R.O.
Note: Lap SAF seams
3” min.
Install fully-soldered wall cap with insect
screen into R.O. with “S.S. pan-head
screws” or “hot-dip galvanized nails”.
Note: Secure wall cap within 1.5” of R.O. into
solid blocking.
![Page 55: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/55.jpg)
Page 14 of 30
Step 1: Install SAF along sides of collar
flange.
Step 2: Install 6” min. wide SAF along top
flange.
Wall Louver 4-Sided Z-Flashing
![Page 56: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/56.jpg)
Page 15 of 30
Louver Head Detail (Detail 3/A9.02)
Primer applied onto louver R.O. surfaces
to receive SAF.
![Page 57: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/57.jpg)
Page 16 of 30
Install SAF along sill of wall cap opening with release paper
remaining on bottom half of SAF or provide starter strip of WRB
prior to SAF installation.
Louver Jamb Detail (Detail 2/A9.02)
![Page 58: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/58.jpg)
Page 17 of 30
Install SAF along jambs and wrapped into jambs of louver
R.O.
Install SAF corners at sill to jamb corners.
Install SAF along head and wrapped into head of louver
R.O.
![Page 59: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/59.jpg)
Page 18 of 30
Apply sealant between nailing flange
and louver
Secure louver to fully soldered collar (see detail). Securing of louver to collar may be done prior to site
installation.
![Page 60: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/60.jpg)
Page 19 of 30
Install SAF at jambs of louver nailing flange.
Install casing bead around sill and jambs
of louver opening, Apply sealant
between louver and casing bead.
![Page 61: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/61.jpg)
Page 20 of 30
Louver Sill Detail (Detail 1/A9.02)
Install GSM head flashing over louver.
![Page 62: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/62.jpg)
Page 21 of 30
Install SAF over head flashing nailing flange. Pocket where casing bead is covered by head flashing, to be filled with sealant.
Stucco Band (Detail 14/AC8.01)
![Page 63: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/63.jpg)
Page 22 of 30
Primer applied onto stucco band surfaces
to receive SAF.
2-pieces of SAF installed in shingled
fashion to wrap stucco band.
Note: Lap SAF seams
3” min.
![Page 64: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/64.jpg)
Page 23 of 30
Set GSM flashing into full bed of sealant on
top shelf of stucco band.
Outside Corner (Detail 5/A8.01)
![Page 65: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/65.jpg)
Page 24 of 30
Install 18” wide SAF on outside corner over
WRB.
Corner aid installed secured 6” min. o.c.
![Page 66: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/66.jpg)
Page 25 of 30
Inside Corner (Detail 4/A8.01)
Provide 18” wide SAF at inside corner over
WRB.
Note: Not performed on mockup building
![Page 67: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/67.jpg)
Page 26 of 30
Horizontal Control Joint
(Detail 7/A8.01)
(No Photo)
Apply SAF onto substrate at horizontal control joint location with release paper
remaining on bottom half of SAF or provide starter strip of WRB
prior to SAF installation.
![Page 68: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/68.jpg)
Page 27 of 30
(No Photo)
Secure horizontal control joint with
fastener, apply SAF over upper flange, and wire tie bottom flange
to lath.
Note: Lath discontinuous at
control joint locations.
Vertical Control Joint
(Detail 6/A8.01)
![Page 69: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/69.jpg)
Page 28 of 30
Install SAF in vertical control joint locations
over WRB.
Secure vertical control joint 6” min. o.c
Note: Lath to be discontinuous at
vertical control joints and wire tied 6” min.
o.c.
![Page 70: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/70.jpg)
Page 29 of 30
Stucco Control Joint Intersection
(Detail 8/A8.01)
Install horizontal control joint intersection
continuous with the vertical control joint discontinuous at the
intersection. Intersection to be set into a bed of sealant over a secured sheet metal backer plate.
![Page 71: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/71.jpg)
Page 30 of 30
Typical Exterior Wall (Detail 1/A8.01)
Lath to be secured to structure w/furring
nails/screws 16” o.c. horizontally and 6”
o.c. vertically.
![Page 72: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/72.jpg)
EXTERIORINTERIOR
(E) WOOD STUD
(E) 5/8" GYPSUM BOARD. SEECUT & PATCH SHEETS FOR GYPBRD. REMOVE AND REPLACESCOPE.
PLYWOOD SHEATHING:REPLACE OSB W/ PLYWOOD SHEATHINGWHERE DAMAGED
BATT INSULATION:REPLACE FOIL FACED BATT INSULATION W/UNFACED BATT INSULATION OF EQUAL R-VALUE
(N) CEMENT PLASTER ANDLATH
(N) WRB
NOTES:1. ALL LATHING IS TO BE ATTACHED WITH FURRING NAILS.2. SEE DETAIL #2 FOR TYPICAL CORNER REINFORCEMENT.
REF. DWG:
SCALE:
TITLE: DWG. NO:
ATTACHED TO:
DATE:
3" = 1'-0"
12/5/2014 2:43:36 PM
12/05/14
ASK1004.1
EXT. WOOD STUD WALL - STUCCO
U.C. SANTA CRUZ INFILL APMNTS REPAIRS1/A8.01
![Page 73: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/73.jpg)
STEP 1:APPLY WRBBELOWBOLT
STEP 2:APPLY SAF"SILL" ATBOLT
STEP 3:APPLY SAF"HEAD" ATBOLT
STEP 4:APPLYSEALANTALL AROUNDBOLT & SAF
REF. DWG:
SCALE:
TITLE: DWG. NO:
ATTACHED TO:
DATE:
3" = 1'-0"
12/5/2014 2:43:36 PM
12/03/14
ASK1004.2
SCAFFOLD BOLT WATERPROOFING
U.C. SANTA CRUZ INFILL APMNTS REPAIRS3/A8.01
![Page 74: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/74.jpg)
18"W SAF. (CENTERED ON CORNER) OVERW.R.B. AT CORNERS
LATH, BEND AT INSIDE CORNER, ATTACH TIGHT TO INSIDECORNER SUBSTRATE. EXTEND MIN. 24" PAST CORNER. DONOT CUT MEMBRANE WHEN INSTALLING LATH
WRB
LATH FASTENERS @ 6" O.C.INTO SOLID BLOCKING, TYP.
NEW LATHATTACHMENTBLOCKING, TYP.
REF. DWG:
SCALE:
TITLE: DWG. NO:
ATTACHED TO:
DATE:
6" = 1'-0"
12/5/2014 2:43:36 PM
12/03/14
ASK1004.3
CEMENT PLASTER STUCCO
U.C. SANTA CRUZ INFILL APMNTS REPAIRS4/A8.01
INSIDE CORNER
![Page 75: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/75.jpg)
18" SAF (CENTERED ON CORNER)OVERW.R.B. AT CORNERS
GALVANIZED WIRE EXTERIORCORNER REINFORCING, TYP.WIRE-TIE TO WALL LATH
METAL LATH
FASTENERS FOR CORNERREINFORCING @ 6" O.C. VERT.-TO HIT BLOCKING-NAIL HEADS FLAT, DO NOT BEND& PUNCTURE W.R.B.
W.R.B.
FILL SPACE SOLID W/ BASECOAT CEMENT PLASTER
REF. DWG:
SCALE:
TITLE: DWG. NO:
ATTACHED TO:
DATE:
6" = 1'-0"
12/5/2014 2:43:37 PM
12/05/14
ASK1004.4
CEMENT PLASTER STUCCO
U.C. SANTA CRUZ INFILL APMNTS REPAIRS
OUTSIDE CORNER
5/A8.01
![Page 76: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/76.jpg)
CEMENT PLASTER STUCCO
METAL LATH
12" W, 40 MIL. S.A.F. STRIP (SOLID LINE)INSTALL OVER W.R.B. ANDCONTINUOUS BEHIND CONTROL JOINT
GSM CONTROL JOINT (XJ-15). UNDER WIRELATH, FASTEN TO STUDS AND BLOCKING
W.R.B. (DASHED LINE) CONT.BEHIND C.J., TYP.
DO NOT PAINT INSIDE
VERIFY EXISTING FRAMING. PROVIDEVERTICAL FLAT BLOCKING (2X4 MIN.)OR DOUBLE STUDS BEHIND C.J, ASREQUIRED.
NOTE:1. VERTICAL CONTROL JOINTS LOCATEDWHERE SHOWN ON ELEVATION.
C.J FASTENER @6" O.C.
WIRE TIE @ 6" O.C.
REF. DWG:
SCALE:
TITLE: DWG. NO:
ATTACHED TO:
DATE:
12" = 1'-0"
12/5/2014 2:43:37 PM
12/05/14
ASK1004.5
STUCCO CONTROL JOINT - VERTICAL
U.C. SANTA CRUZ INFILL APMNTS REPAIRS6/A8.01
![Page 77: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/77.jpg)
3-COAT CEMENT PLASTER STUCCO
METAL LATH
S.A.F. 12" WIDE
GSM CONTROL JOINT ("#15 SOLID LEG" OREQUAL). UNDER WIRE LATH, FASTEN TOSTUDS AND/OR BLOCKING.
W.R.B.
DO NOT PAINT INSIDE
S.A.F. STRIP IN, 9" WIDE, MIN.
C.J. FASTENERS @ 6" O.C., TYP.
WIRE TIE @ 6" O.C., TYP.
PROVIDE (N) BLOCKING (2x4 MIN.)
NOTES:1.PROVIDE SOLID WOOD BLOCKING (2X4 MIN.) FORFASTENING CONTROL JOINT, TYPICAL2. HORIZ. CONTROL JOINTS ALIGN W/ WINDOW SILLS,AND AT WINDOW HEAD AT TOP FLOOR, SEEELEVATIONS.
(E) FRAMING
REF. DWG:
SCALE:
TITLE: DWG. NO:
ATTACHED TO:
DATE:
12" = 1'-0"
12/5/2014 2:43:37 PM
12/05/14
ASK1004.6
STUCCO CONTROL JOINT - HORIZ.
U.C. SANTA CRUZ INFILL APMNTS REPAIRS7/A8.01
![Page 78: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/78.jpg)
STEP 7: 12" WIDE SAF
STEP 6: WRB
STEP 8: VERTICAL CONTROL JOINT,DISCONTINUOUS @ CJ INTERSECTION.SEE VERTICAL CJ DETAIL.
STEP 4: CONTINOUS HORIZONTAL CONTROLJOINT. SEE HORIZONTAL CJ DETAIL.
STEP 3: SHEET METAL BACKER PLATETYPICAL AT ALL INTERSECTIONS. JOINTSAND BUILDING CORNERS.
FASTEN BOTH FLANGES OF EACHCONTROL JOINT THROUGH BACKER PLATETO FRAMING. (SOME NOT SHOWN FORCLARITY.)
CUT ENDS OF VERTICAL CONTROL JOINTSTO MATCH ANGLE OF HORIZONTALCONTROL JOINT SURFACE.DO NOT SEAL LOWER END OF VERTICALCONTROL JOINT. LEAVE OPEN TO WEEP.
STEP 5: 9" WIDE SAF (SHOWN IN WHITE)OVER HORIZ. C.J.
STEP 2: 12" WIDE SAF
APPLY SEALANT FILLET AROUND ALL SIDESOF JUNCTURE - UPPER END OF VERTICALJOINT ONLY.
EMBED UPPER END OF VERTICALCONTROL JOINT IN A FULL BED OFSEALANT 2" WIDE. COMPLETELY FILL ALLSPACE BETWEEN CONTROL JOINT ANDBACKER PLATE.
STEP 1: WRB
REF. DWG:
SCALE:
TITLE: DWG. NO:
ATTACHED TO:
DATE:
3" = 1'-0"
12/5/2014 2:43:38 PM
12/05/14
ASK1004.7
STUCCO CONTROL JOINT
U.C. SANTA CRUZ INFILL APMNTS REPAIRS8/A8.01
INTERSECTION
![Page 79: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/79.jpg)
24 GA GSM BACKPLATE. TYP. ATCORNERS
SET CONTROLJOINTS IN A FULL BEDOF SEALANT 2" WIDE,COMPLETELY FILLINGBACK OF PROFILE
CONTROL JOINT, SEEHORIZONTAL CJ DETAIL.
2".
2". 2".
REMOVE ANY"SQUEEZE-OUT"
CONTROL JOINT
MITER CONTROL JOINTS ANDSET IN A FULL BED OF SEALANT2" WIDE, COMPLETELY FILLINGBACK OF PROFILE.ISOMETRIC VIEW
NOT TO SCALE
PROVIDE (N) SOLIDWOOD BLOCKING (2X4MIN.) FOR FASTENINGCONTROL JOINT,TYPICAL
REF. DWG:
SCALE:
TITLE: DWG. NO:
ATTACHED TO:
DATE:
12" = 1'-0"
12/5/2014 2:43:38 PM
12/05/14
ASK1004.8
STUCCO CONTROL JOINT
U.C. SANTA CRUZ INFILL APMNTS REPAIRS9/A8.01
HORIZONTAL/CORNER
![Page 80: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/80.jpg)
NOTES:1. SHEET METAL J-MOLD RECEIVER.2. SOLDER TO FORM ONE CONTINUOUS WATERTIGHT PIECE.3. FIELD VERIFY DIMENSIONS AND CONDITIONS.
4"
MIN
. LA
P, P
ER
SM
AC
NA
4" TYP.
SPOT WELD ANDSOLDER WATERTIGHT
26 GA GSM
BACKER ROD ANDSILICONE SEALANTCONTINUOUS AROUNDPENTRATION
SIZE ALL ALLOW 1/2" SEALANTJOINT ON ALL SIDES
OUTLINE OF PENTRATION(DASHED)
FILL IN CORNERS ANDDE-BURR EDGES, TYP.
REF. DWG:
SCALE:
TITLE: DWG. NO:
ATTACHED TO:
DATE:
1 1/2" = 1'-0"
12/5/2014 2:43:39 PM
12/05/14
ASK1004.9
FLANGED PENETRATION FLASHING
U.C. SANTA CRUZ INFILL APMNTS REPAIRS11/A8.01
![Page 81: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/81.jpg)
CEMENT PLASTER
METAL LATH
SAF
FASTENER
PLYWOOD SHEATHING
FULLY SOLDERED SHEET METALESCUTCHEON FLASHING. TO BE 2-PIECEWHERE PENETRATION IS EXISTING.
ALL S
IDE
S
3/8
" T
YP
.
.SEE NOTE 2
SEALANT FILLETCONTINUOUS
PENETRATION, VARIES, MAYBE ROUND OR SQUARE
HOLD WRB DOWN 3" FROMPENETRATION
NOTES:
WHERE SHEATHING GAP IS GREATER THAN 1/8", INSTALL LOW EXPANSION URETHANE FOAM INACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. SHAVE CURED FOAM FLUSH WITHSHEATHING.
SHEATHING GAP OF 1/8" OR LESS, TYP. ALL SIDES NO FOAM REQUIRED.
1.
2.
SEE NOTE 1BACKER ROD AND SEALANT.WHERE PENETRATION MUST BEFIRE-RATED, REPLACE BACKERROD W/ FIRE CAULKING.
WRB
SAF, 6" WIDE OVER FLANGE AT TOP AND SIDES
SAF, 6" WIDE CONTINUOUSAROUND ALL SIDES OFPENETRATION. CUT TO FITTIGHT TO PENETRATION
REF. DWG:
SCALE:
TITLE: DWG. NO:
ATTACHED TO:
DATE:
12" = 1'-0"
12/5/2014 2:43:39 PM
12/05/14
ASK1004.10
FABRICATED PENETRATION FLASHING
U.C. SANTA CRUZ INFILL APMNTS REPAIRS13/AC8.01,10/AP8.01
![Page 82: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/82.jpg)
PLYWOOD SHEATHING, S.S.D.
GSM FLASHING W/ HEMMED END. SET INSEALANT
CEMENT PLASTER STUCCOW/ LATH OVER SAF
USE (N) PLYWOOD BLOCKING TO REPLACE (E)FOAM BELT COURSE TRIM. MATCH EXISTINGLOCATION AND DIMENSIONS.
FASTENERS @ 6" O.C., TYP.
CEMENT PLASTER STUCCO W/ LATH
24 GA GSM DRIP EDGE WITHS.S. FASTENERS
FASTENER
9" SAF, LAP OVER WEEP SCREED
WRB. OVER SAF AND WEEP SCREED
SAF LAP OVER WRB
(E) FRAMING
3/4"
MA
TC
H E
XIS
TIN
G 1
'-0"
BACKER SAF LAPPED OVER BAND PLYWOOD
REF. DWG:
SCALE:
TITLE: DWG. NO:
ATTACHED TO:
DATE:
3" = 1'-0"
12/5/2014 2:43:39 PM
12/05/14
ASK1004.11
STUCCO BAND DETAIL
U.C. SANTA CRUZ INFILL APMNTS REPAIRS14/AC8.01
![Page 83: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/83.jpg)
CEMENT PLASTER STUCCO W/ LATH
24 GA GSM SILL SCREED WITH S.S.FASTENERS
PLYWOOD SHEATHING, S.S.D.
FASTENER
TY
P.
1/2
".
MIN
.
1".
2" MIN. @ PAVING,6" MIN. @ GRADE
9" SAF, LAP OVER SILL SCREED
WRB. OVER SAF AND SILL SCREED
*REPLACE SILL SCREED AND GSMBASE FLASHING W/ GSM CASINGBEAD AT VERTICAL FOUNDATIONWALL EDGES. TYP.
WHERE REQ'D. 2" CLEARANCE EXPOSESFRAMING, INSTALL 6" STAINLESS STEELWALL FLASHING AGAINST WALL BEHINDTHE STUCCO BASE FLASHING. REMOVESEALANT AND FILLER FROM GAPBETWEEN CONCRETE PAVING AND WALLTO ALLOW METAL FLASHING TO EXTENDMINIMUM 1" BELOW SURFACE OF PAVING.THIS WALL FLASHING SHOULD BE SET INBUTYL SEALANT.SEAL JOINT BETWEEN NEW FLASHING ANDPAVING CONCRETE AFTER FLASHING ISINSTALLED.AT OUTSIDE CORNERS, TURN FLASHINGAROUND CORNER 6".
REF. DWG:
SCALE:
TITLE: DWG. NO:
ATTACHED TO:
DATE:
3" = 1'-0"
12/5/2014 2:43:40 PM
12/05/14
ASK1004.12
BASE OF WALL
U.C. SANTA CRUZ INFILL APMNTS REPAIRS6/AC8.02, 7/AP8.02
![Page 84: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/84.jpg)
TY
P.
4"
MIN
.4"
MIN
.
SAF, 9" WIDE OVER FLANGE ATTOP AND SIDES
WRB
CEMENT PLASTER
METAL LATH
FULLY SOLDERED GSMCOLLAR FLASHING
(E) ELECTRICAL BOX
INSTALLWEATHERPROOFGASKET TO REPLACE (E)
(E) LIGHT FIXTURE,REMOVE ANDREINSTALL. DETACH,DISCONNECT ANDREATTACH ASREQUIRED.
SEALANT FILLET, ALLSIDES
REF. DWG:
SCALE:
TITLE: DWG. NO:
ATTACHED TO:
DATE:
6" = 1'-0"
12/5/2014 2:43:40 PM
12/05/14
ASK1004.13
ELECTRICAL BOX PENETRATION
U.C. SANTA CRUZ INFILL APMNTS REPAIRS
FLASHING
8/AC8.02, 9/AP8.02
![Page 85: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/85.jpg)
2.STAINLESS STEEL L-METAL. CONTINUOUSTO EACH END (SHOWNCUT FOR CLARITY).STRIP INTOWATERPROOFMEMBRANE
4"
+/- 4". EXTEND 1"ABOVE SILLSCREED. FOLDOVER CASINGBEAD ON TO SILLSCREED
6"
6"
8"
12"
CASING BEAD.SPOT WELD ANDSOLDER TOSADDLE
STRIP INWITH SAF
4"
4"
6"
1.26 GA STAINLESS STEELSADDLE. APPLIED PRIOR TOWATERPROOFING MEMBRANES,BUT OVER WALL FLASHING(WHERE IT EXISTS)
3.CONFORM STAINLESS STEEL DECKEDGE. CONTINUOUS TO EACH END(SHOWN CUT FOR CLARITY). APPLYOVER WATERPROOFING, ANDUNDER CONC. SLAB
REF. DWG:
SCALE:
TITLE: DWG. NO:
ATTACHED TO:
DATE:
3" = 1'-0"
12/5/2014 2:43:40 PM
12/05/14
ASK1004.14
DECK EDGE SADDLE AT WALL
U.C. SANTA CRUZ INFILL APMNTS REPAIRS6/A8.22
![Page 86: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/86.jpg)
STAINLES STEEL CON-FORM DECK EDGE METAL
HOT FLUID APPLIED WATERPROOFING MEMBRANE, TYP.(CROSS HATCH)
DRAINAGE COMPOSITE
REMOVE EDGE OF (E) SLAB
PROTECTION BOARD (GREY)
REINFORCING FABRIC (DASHED)
24GA STAINLESS STEEL EDGE METAL. SET IN WPMEMBRANE AND FASTEN @ 4" O.C., 2-ROWSSTAGGERED (PER MANUFACTURER)
NEOPRENEREINFORCING WRAP, DOWN FACE OF WALL,OVER BONDING ADHESIVE
6"
1/2" THICK BUILDUP
1/2
"
STAINLES STEEL CON-FORM DECK EDGE METAL
HOT FLUID APPLIED WATERPROOFING MEMBRANE, TYP.(CROSS HATCH)
DRAINAGE COMPOSITE
CUT BACK EDGE OF (E) PLYWOOD SHEATHING
PROTECTION BOARD (GREY)
REINFORCING FABRIC (DASHED)
24GA STAINLESS STEEL EDGE METAL. SET IN WPMEMBRANE AND FASTEN @ 4" O.C., 2-ROWS STAGGERED(PER MANUFACTURER)
NEOPRENEREINFORCING WRAP, DOWN FACE OF WALL,OVER BONDING ADHESIVE
(E) PLYWOOD DECK
REF. DWG:
SCALE:
TITLE: DWG. NO:
ATTACHED TO:
DATE:
6" = 1'-0"
12/5/2014 2:43:41 PM
12/05/14
ASK1004.15
DECK EDGE AT LANDING
U.C. SANTA CRUZ INFILL APMNTS REPAIRS8/A8.22
PORTER
COWELL
![Page 87: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/87.jpg)
STD. WEIGHT CONC. TOPPING SLAB, MIN 1-1/2"
HOT FLUID APPLIED WATERPROOFINGMEMBRANE, TYP. (CROSS HATCH)
DRAINAGE MAT
(E) CONC. SLAB ON METAL DECK
HOT FLUID APPLIEDMEMBRANE FILLET
PROTECTION COURSE (GREY)
WIRE REINFORCEMENT
STAINLESS STEEL FLASHING, EXTEND ABOVEDRIP EDGE OF WEEP SCREED 3" MIN. & 1/2"BELOW TOP OF PAVING. HEM BOTTOM @ EDGE
NEOPRENE REINFORCING, RUN UP WALL
REINFORCING FABRIC (DASHED)
BACKER ROD AND SEALANT OVERCOMBRESSIBLE FILLER BOARD
STD. WEIGHT CONC. TOPPING SLAB, MIN 1-1/2"
HOT FLUID APPLIED WATERPROOFINGMEMBRANE, TYP. (CROSS HATCH)
DRAINAGE MAT
(E) DECK STRUCTURE
PROTECTION COURSE (GREY)
WIRE REINFORCEMENT
STAINLESS STEEL FLASHING, EXTEND ABOVEDRIP EDGE OF WEEP SCREED 3" MIN. & 1/2"BELOW TOP OF PAVING. HEM BOTTOM @ EDGE
NEOPRENE REINFORCING, RUN UP WALL
BACKER ROD AND SEALANT OVERCOMBRESSIBLE FILLER BOARD
REINFORCING FABRIC (DASHED)
HOT FLUID APPLIEDMEMBRANE FILLET
REF. DWG:
SCALE:
TITLE: DWG. NO:
ATTACHED TO:
DATE:
6" = 1'-0"
12/5/2014 2:43:41 PM
12/05/14
ASK1004.16
ENLARGED DECK TO WALL DETAIL
U.C. SANTA CRUZ INFILL APMNTS REPAIRS
PORTER
COWELL
9/AC8.22, 7/AP8.22
![Page 88: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/88.jpg)
(E) SPRINKLER PIPE
(E) METAL DECK W/ STRUCTURALCONC. SLAB
CONC. TOPPING SLAB,1-1/2" MIN. THICKNESS
FILTER FABRIC (DASHED)
HOT RUBBER WATERPROOFING(CROSS HATCH)
PROTECTION BOARD (GREY)
DRAINAGE LAYER
STAINLESS STEEL (2-PIECE) COLLAR. HEMTOP EDGE. 2" HORIZ. LEG ON DECK
SURFACE. SET IN FULL BED OF SEALANTAND FASTEN TO DECK, PER HOT RUBBER
MANUF. REQUIREMENTS.
BACKER ROD & SEALANT
3/8" MIN., TYP.
(E) CLAMP. ADJUST TO ALLOWWATERPROOFING AND POURING
OF TOPPING SLAB
REF. DWG:
SCALE:
TITLE: DWG. NO:
ATTACHED TO:
DATE:
3" = 1'-0"
12/5/2014 2:43:42 PM
12/05/14
ASK1004.17
PIPE PENETRATION
U.C. SANTA CRUZ INFILL APMNTS REPAIRS11/AC8.22
WATERPROOFING AT DECK
![Page 89: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/89.jpg)
HOT FLUID APPLIED WATERPROOFINGMEMBRANE, TYP. (CROSS HATCH)
DRAINAGE MAT
HOT FLUID APPLIEDMEMBRANE FILLET
PROTECTION COURSE (GREY)
STAINLESS STEEL FLASHING. UPTURN ATBASE COLUMN. HEM BOTTOM @ EDGE. HEM
TO FOLD 'IN'
EXISTING REDWOOD COLUMN
NEOPRENE REINFORCING, RUN UP WALL
REINFORCING FABRIC (DASHED)
BACKER ROD AND SEALANT OVERCOMBRESSIBLE FILLER BOARD
ROUTED GROOVE W/ SEALANT
1/2
"
REF. DWG:
SCALE:
TITLE: DWG. NO:
ATTACHED TO:
DATE:
6" = 1'-0"
12/5/2014 2:43:42 PM
12/05/14
ASK1004.18
DECK COLUMN WATERPROOFING
U.C. SANTA CRUZ INFILL APMNTS REPAIRS6/AP8.22
(PORTER)
![Page 90: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/90.jpg)
(E) WOOD COLUMN
HOT RUBBERWATERPROOFING
SYSTEM (HATCHED)
(E) WOOD DECK STRUCTURE
AT CORNER, USE FULLYSOLDERED EDGE METAL PIECETO WRAP AROUND OUTSIDECORNER OF COLUMN
(E) WOOD COLUMN
HOT RUBBERWATERPROOFING
SYSTEM (HATCHED)
(E) WOOD DECK STRUCTURE
EDGE METAL
FULLY SOLDEREDSTAINLESS STEELCOUNTERFLASHINGAROUND COLUMN. KEY INTOKERF CUT IN COLUMN ANDSEAL. BOTTOM EDGE OFCOUTER FLASHING TO BEHEMMED IN.
KERF CUT IN COLUMN
1. EDGE METAL @ CORNER (BEFORE COUNTER FLASHING INSTALL)
2. CORNER FLASHING (W/ COUNTER FLASHING)
REF. DWG:
SCALE:
TITLE: DWG. NO:
ATTACHED TO:
DATE:
1 1/2" = 1'-0"
12/5/2014 2:43:43 PM
12/05/14
ASK1004.19
DECK COLUMN FLASHING (PORTER)
U.C. SANTA CRUZ INFILL APMNTS REPAIRS
![Page 91: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/91.jpg)
SHIM AS REQUIRED BYWINDOW MANUF. FORWINDOW SUPPORT.
W.R.B.
3/4"X3/4" 24 GA GSM ANGLE
1X WD. WINDOW SILL
1/2"
1/2" WD. WINDOW APRON
SHIM
CONT. SLOPED SHIM
1/16" HORSESHOE SHIM ATFASTENERS AT SILL ONLY
ALUMINUM WINDOW, SEESPECIFICATIONS
CONT. SEALANT BEAD
SAF, O/ WRB, WRAPPED UP ONTO ANGLE
BACKER ROD AND SEALANT
(EXISTING STRUCTURE)
ROTO CRANK
SHADE
BASE SAF @ SILL
REF. DWG:
SCALE:
TITLE: DWG. NO:
ATTACHED TO:
DATE:
6" = 1'-0"
12/5/2014 2:43:43 PM
12/05/14
ASK1004.20
WINDOW SILL WATERPROOFING
U.C. SANTA CRUZ INFILL APMNTS REPAIRS1/A9.01
![Page 92: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/92.jpg)
BACKER ROD ANDSEALANT
W.R.B., LAP OUTER LAYER O/ WINDOW FIN
12" SAF, LAP O/ WINDOW FIN
SAF, RUN INTO ROUGH OPENING
CEMENT PLASTER STUCCO
3/4"X1" (SHORT LENGTH AGAINSTWNDW), 24 GA GSM ANGLE W/HEMMED EDGE. SET IN A FULLBED OF SEALANT O/ SAF ANDFASTEN @ 12" O.C., MIN.
SET HEAD AND JAMB FLANGES IN SEALANT
ALUNIMUM WINDOW, SEESPECIFICATIONS
(N) GYP. BRD. WINDOW WRAP
SHIM TO CREATE EQUAL (+/- 1/4")WINDOW FRAME REVEAL ONJAMB SIDES, TYP.
(EXISTING STRUCTURE)~
1 3
/16"
SHADE OVERLAP PAST JAM, TYP.
2"
SHADE
REF. DWG:
SCALE:
TITLE: DWG. NO:
ATTACHED TO:
DATE:
6" = 1'-0"
12/5/2014 2:43:43 PM
12/05/14
ASK1004.21
WINDOW JAMB WATERPROOFING
U.C. SANTA CRUZ INFILL APMNTS REPAIRS2/A9.01
![Page 93: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/93.jpg)
W.R.B.LAP OUTER LAYER O/ HEAD FLASHING
12" SAF, EXTEND O/ HEAD FLASHINGS
GSM HEAD FLASHING (PAINT)W/ HEMMED EDGE.EXTEND UP WALL 4" MIN.
ALUMINUM WINDOW, SEESPECIFICATIONS
9" SAF, LAP O/ WINDOW FIN
SEALANT W/ BACKER ROD
L-METAL, TYP.
(N) GYP. BRD. WINDOW WRAP
SAF, RUN INTO ROUGH OPENING
CEMENT PLASTER STUCCO
SET HEAD AND JAMB FLANGES IN SEALANT
(EXISTING STRUCTURE)
SEALANT FILLET
~ 3 9/16"
BLACKOUTWINDOW SHADEUNIT
1-1/8" X 3-1/2"CONTINUOUS PAINTEDBLOCKING
SHADE
1 1/8"
HEAD FLASHING FASTENERS. FASTENERCANNOT PENETRATE WINDOW HEAD FIN.KEEP FASTENER CLEAR OF LEADINGEDGE OF WINDOW FIN.
REF. DWG:
SCALE:
TITLE: DWG. NO:
ATTACHED TO:
DATE:
6" = 1'-0"
12/5/2014 2:43:43 PM
12/05/14
ASK1004.22
WINDOW HEAD WATERPOOFING
U.C. SANTA CRUZ INFILL APMNTS REPAIRS3/A9.01
![Page 94: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/94.jpg)
NAIL HEADS SET FLUSH WITH FACEOF SHEATHING
STEP B1: 1'-0" WIDE SAF (40MIL); EXTEND 1'-0" BEYONDROUGH OPENING EACH SIDE; ADHERE TOPHALF TO EDGE OF ROUGH OPENING, LEAVEBOTTOM HALF LOOSE (W/ RELEASE PAPERINTACT) ALLOWING FOR BUILDING PAPER ATSTEP H (STAPLE AT LOWER CORNERS TOPREVENT WIND DAMAGE)
STEP A
STEP B
STEP C
STEP D
STEP E
STEP F
STEP G
12" WIDE SAF (25 MIL) COVERING ENTIREROUGH SILL (AND OVER GSM ANGLE ANDSHIM); EXTEND 4" UP JAMB
EXTEND 4" BEYOND ROUGHOPENING
NOTE:REMOVE ALLLABELS FROMWINDOWFLANGE PRIORTOINSTALLATION
NOTE:APPLY SAF WITH LAMINATE ROLLER PERMANUFACTURER INSTRUCTIONS,ELIMINATE ALL WRINKLES AND AIRPOCKETS
STEP D1:SAF (25 MIL) COVERING ENTIRE ROUGHOPENING(AND UNDER GSM ANGLE).CUT AT SILL-TO-JAMB CORNER AND RUNONTO SILL AND FACE OF WALL 4"
STEP B2:PROVIDE 3" DIA SAF CIRCLE PATCHES(25 MIL) TO SEAL ANY PINHOLEOPENINGS AT OUTSIDE FRAMINGCORNERS
INSTALL WINDOW PERMANUFACTURER INSTRUCTIONS. HEADFASTENERS PER DETAIL. SHIM ANDADJUST AS REQUIRED TO SQUARE,PLUMB AND LEVEL WINDOW UNIT
PRIOR TO SETTING WINDOW UNIT APPLYCONTINUOUS BEAD OF SEALANT TO BACKSIDE OF MOUNTING FLANGEEXCEPT AT SILL WHERE PAN OCCURS
SET FASTENER HEADS FLUSH WITHFLANGE; DO NOT BEND FASTENERHEADS OVER
9" WIDE SAF (25 MIL) OVERWINDOW FLANGE AT JAMB;EXTEND 6" BEYOND SILL AND HEADROUGH OPENING
NOTE:HEAD FLASHING TO BECONTINUOUS WITH NOJOINTS WITH MIN. 4"VERTICAL LEG. SLOPETOP TO DRAINOUTWARD. PROVIDECLOSED ENDS WITHALL JOINTSSOLDERED.
NOTE:LAP BUILDINGPAPER OVER HEADFLASHING
LAP 6" MIN. ATVERTICAL SEAMS,4" MIN. ATHORIZONTALSEAMS
AVOID DAMAGE TOPREVIOUSFLASHINGMATERIALS WHENTRIMMING BUILDINGPAPER
TUCKBUILDINGPAPERUNDER SILLFLASHING,SEE STEP B
STEP G1:APPLY 9" WIDE SAF (25 MIL) OVERWINDOW HEAD, EXTEND 3" BEYONDJAMB FLEXIBLE FLASHING
STEP G2:INSTALL GALVANIZED SHEET METAL HEADFLASHING, LAP OVER WINDOW HEAD PERDETAIL. END DAMS TO EXTEND 3/4" ON EACHSIDE OF WINDOW W/ 3" FLANGE ON EACH END,SOLDER RETURNS.
STEP H
WRB
1'-0"
4"
PRIME GYPSUM SHEATHING ANDPLYWOOD SHEATHING. PER SAFSPECS
FILL JOINT GAPS > 1/8" WITHSEALANT
STEP G3:ADD 12" WIDE SAF (25MIL) STRIPOVER GSM HEAD FLASHING
4"
4"
3/4" MIN
STEP H: FLASHING TAPEOVER WRB EDGE, PERDETAIL. @ HEAD AND JAMONLY
STEP D2:SAF (25 MIL) COVERING ENTIRE ROUGHOPENING.CUT AT HEAD-TO-JAMB CORNER ANDRUN ONTO HEAD AND FACE OF JAM 4"
3"
APPLY APPROVED SAF PATCHES TO SEALPIN HOLE OPENINGS AT ANGLE TO JAMBINTERSECTIONS
ROUGH OPENINGS TO BE SHIMMED W/DIMENSIONAL LUMBER, NOT PLYWOOD
REF. DWG:
SCALE:
TITLE: DWG. NO:
ATTACHED TO:
DATE:
1611 Telegraph Avenue, Suite 200Oakland, California 94612
510.465.7010 p | 510.465.8575 fwww.pyatok.com
1/4" = 1'-0"
12/5/2014 2:45:58 PM
12/05/14
ASK 1004.23WINDOW FLASHING SEQUENCE DIAGRAM
U.C. SANTA CRUZ INFILL APMNTS REPAIRS4/A9.01
![Page 95: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/95.jpg)
STEP A
STEP B
STEP C
STEP D
STEP E
PRIME GYPSUM SHEATHINGAND PLYWOOD SHEATHING.PER SAF SPECS
FILL JOINT GAPS > 1/8"WITH SEALANT
SILL CORNER SAF
SILL SAF
JAMB SAF
HEAD SAF. CONTINUOUSONTO FACE OF R.O.
REF. DWG:
SCALE:
TITLE: DWG. NO:
ATTACHED TO:
DATE:
1/4" = 1'-0"
12/5/2014 2:43:44 PM
12/05/14
ASK1004.24
WALL OPENING FLASHING
U.C. SANTA CRUZ INFILL APMNTS REPAIRS
SEQUENCING DIAGRAM
*THIS INSTALLATION SEQUENCE IS NOTAPPLICABLE TO THE DOOR OR WINDOWOPENINGS
![Page 96: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/96.jpg)
INSECT SCREEN & FASTENINGPLATE. REMOVE AND REINSTALLOVER NEW CONT. Z-FLASHING
FULLY SOLDERED CONT.GSM Z-FLASHING
(EXISTING STRUCTURE)
W.R.B.
12" S.A.F., WRAP UP INTOFULL DEPTH OF OPENING
SEALANT AND BACKER ROD
FASTENER
CEMENT PLASTER STUCCOW/ METAL LATH
STUCCO CASING BEAD
REPAIR GYP. BD. FINISH
LOUVER
CONT. SEALANT BTWNLOUVER AND Z-FLASHING
REF. DWG:
SCALE:
TITLE: DWG. NO:
ATTACHED TO:
DATE:
6" = 1'-0"
12/5/2014 2:43:45 PM
12/05/14
ASK1004.25
LOUVER SILL WATERPROOFING
U.C. SANTA CRUZ INFILL APMNTS REPAIRS1/A9.02
![Page 97: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/97.jpg)
CEMENT PLASTER STUCCOW/ METAL LATH
(EXISTING STRUCTURE)
INSECT SCREEN & FASTENINGPLATE. REMOVE AND REINSTALLOVER NEW CONT. Z-FLASHING
FULLY SOLDERED CONT. GSM Z-FLASHING
W.R.B.(ABOVE SAF)
12" S.A.F., WRAP UP INTO FULL DEPTH OFOPENING
SEALANT AND BACKER ROD
FASTENER
STUCCO CASING BEAD
REPAIR GYP. BD. FINISH
LOUVER
CONT. SEALANT BTWN LOUVER AND Z-FLASHING
6" SAF OVER FLASHING
REF. DWG:
SCALE:
TITLE: DWG. NO:
ATTACHED TO:
DATE:
6" = 1'-0"
12/5/2014 2:43:45 PM
12/05/14
ASK1004.26
LOUVER JAMB WATERPROOFING
U.C. SANTA CRUZ INFILL APMNTS REPAIRS2/A9.02
![Page 98: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/98.jpg)
HEAD DRIP FLASHING TO EXTEND PASTLOUVER TO ALLOW TO COVER OVERSTUCCO CASING BEAD, SET IN CONT.COMPATIBLE SEALANT BED
12" S.A.F., RUN INTO ROUGH OPENING
(EXISTING STRUCTURE)
12" S.A..F, EXTEND O/ Z-FLASHING& HEAD FLASHING
CO
VE
R
1"
MIN
.
INSECT SCREEN & FASTENINGPLATE. REMOVE AND REINSTALLOVER NEW CONT. Z-FLASHING
REPAIR GYP. BD. FINISH
LOUVER
CONT. SEALANT BTWN LOUVER AND Z-FLASHING
REF. DWG:
SCALE:
TITLE: DWG. NO:
ATTACHED TO:
DATE:
6" = 1'-0"
12/5/2014 2:43:45 PM
12/05/14
ASK1004.27
LOUVER HEAD WATERPROOFING
U.C. SANTA CRUZ INFILL APMNTS REPAIRS3/A9.02
![Page 99: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/99.jpg)
4" LEG, TYP.
DEPTH OF LOUVER - 7/8"
1" BACK DAM
REF. DWG:
SCALE:
TITLE: DWG. NO:
ATTACHED TO:
DATE:
3" = 1'-0"
12/5/2014 2:43:46 PM
12/05/14
ASK1004.28
WALL LOUVER 4-SIDED Z-FLASHING
U.C. SANTA CRUZ INFILL APMNTS REPAIRS
![Page 100: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/100.jpg)
5/8
"
4"
VERIF
Y
1/4
"10° SLOPE
24 GA. G.S.M. ENDCLOSURE
END DAM EXTENDS 1/4"ABOVE AS SHOWN
3"
4"
5/8
"
VERIFY
10° SLOPE
KICK OUT
1/4" KICK OUT
END DAM
REF. DWG:
SCALE:
TITLE: DWG. NO:
ATTACHED TO:
DATE:
6" = 1'-0"
12/5/2014 2:43:46 PM
12/05/14
ASK1004.29
Z-METAL HEAD FLASHING DETAIL
U.C. SANTA CRUZ INFILL APMNTS REPAIRS5/A9.01, 4/A9.10
![Page 101: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/101.jpg)
5/8" GYP. BD. SOFFIT
SOLDERED WALL CAP W/INTEGRAL COLLAR
FLASHING, SEE DETAIL 9
INTEGRAL COLLAR FLASHINGBEYOND
S.A.F. , WRAP INTO ROUGH OPENING
PLYWOOD SHEATHING, S.S.D.
W.R.B.
S.A.F., EXTEND OVER COLLARFLASHING
(N) DUCT, S.M.D.
NEW BLOCKING ASREQUIRED
(EXISTING FRAMING)
INSECT SCREEN
W.R.B.
METAL LATH
S.A.F., RUN INTO ROUGHOPENING
CEMENT PLASTER
REF. DWG:
SCALE:
TITLE: DWG. NO:
ATTACHED TO:
DATE:
3" = 1'-0"
12/5/2014 2:43:46 PM
12/05/14
ASK1004.30
MAKEUP AIR WALL CAP TERMINATION
U.C. SANTA CRUZ INFILL APMNTS REPAIRS7/AC9.02, 6/AP9.02
![Page 102: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/102.jpg)
8"
4"
4" 8"
R 0' - 3 1/2"
INSECT SCREEN (AT INTAKE),OR 1/4" STAINLESS STEELMESH (AT EXHAUST)
DUCT, S.M.D.
STUCCO DEPTH
4 1/2" 4"
8"
1/4
" R
ET
UR
N
SOLDERED WALLCAP W/ INTEGRALCOLLAR FLASHING
INSECT SCREEN (ATINTAKE) OR 1/4"STAINLESS STEEL MESH(AT EXHAUST), BEYOND
SECTION FRONT ELEVATION BACK SIDE
NOTE:WALL CAPHOOD NOTSHOWN
DUCT RECEIVER,BEYOND
WALL ASSEMBLY
REF. DWG:
SCALE:
TITLE: DWG. NO:
ATTACHED TO:
DATE:
1 1/2" = 1'-0"
12/5/2014 2:43:47 PM
12/05/14
ASK1004.31
WALL CAP AT VENT TERMINATION
U.C. SANTA CRUZ INFILL APMNTS REPAIRS9/A9.02
![Page 103: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/103.jpg)
NOTE:1. TYP. EXT. DOOR FLASHING2. FABRICATE PAN FLASHING OF 24GAUGE GALVANIZED SHEET METAL.FOLD UP VERTICAL EDGE BELOWTHRESHOLD. DO NOT NAIL ATHORIZONTAL SURFACE.
SOLDER ALL JOINTS, TYP.
3/4” HIGH END DAM. HEM EDGE.SEE DETAIL.
4"
4"
5-1/2”
MA
TCH
RO
UG
H O
PE
NIN
G W
IDT
H
TO TOP OFSTRUCTURAL
SLAB. FIELDVERIFY
4"
REF. DWG:
SCALE:
TITLE: DWG. NO:
ATTACHED TO:
DATE:
3" = 1'-0"
12/5/2014 2:43:47 PM
12/05/14
ASK1004.32
SILL PAN FLASHING
U.C. SANTA CRUZ INFILL APMNTS REPAIRS3/A9.10
![Page 104: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/104.jpg)
INSWING DOOR: SEE DOOR SCHEDULE
WEATHERSTRIPPING/ SMOKESEAL:SEE SPECS.
NEW CONCRETE TOPPING SLAB
DRAINAGE MAT
HOT FLUID APPLIED WATERPROOFING MEMBRANE, TYP.(CROSS HATCH). RUN UP ONTO SILL PAN
SEALANT & BACKER ROD
GSM SILL PAN WITH INTEGRAL END CAPS AT JAMS, SET IN FULL BED OFSEALANT APPLIED UNDER SILL & END CAPS. MAINTAIN VERTICAL SHAPEOF END DAM (DO NOT CRIMP DOWN ONTO MEMBRANE). SEE DETAIL 3.SAF OVER UPPER EDGE ALONG JAMS
ALUMINUM SADDLE THRESHOLD, SET INMASTIC SEALANT @ EACH END. INSTALLW/ SCREWS SET IN SEALANT.
SEAL DOOR FRAME TO CONCRETE SLAB(FOAM & SEALANT).
(EXISTING STRUCTURE)
PROTECTION BOARD. DO NOT OVERLAPLAYERS TO AVOID EXCESSIVE BUILD-UP
CANT
FLOORING
NEOPRENE REINFORCING (THICK LINE),RUN UP ONTO SILL PAN
REINFORCING FABRIC (DASHED)
2 LAYERS 1/2" CDX PLYWD
1-1/4" GYPCRETESUB-FLOOR
ACOUSTICAL MAT
1-1/2"FACTORY-PROVIDEDSCREWFASTENER.SET INSEALANT ANDSEAL HEAD.
8 3/4" STEEL DOOR FRAME
DOOR SHOE(PEMKO 216_FG)
.SLOPE
MA
X.
1/2
"
5 1/2"
- 1/8”T.O. TOPPING SLAB
0”T.O. GYPCRETE
REF. DWG:
SCALE:
TITLE: DWG. NO:
ATTACHED TO:
DATE:
6" = 1'-0"
12/5/2014 2:45:33 PM
12/05/14
ASK
1004.33
EXTERIOR DOOR THRESHOLD AT LANDING
U.C. SANTA CRUZ INFILL APMNTS REPAIRS6/A9.10
![Page 105: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/105.jpg)
CEMENT PLASTER STUCCO
(E) GYPSUM BOARD: 5/8"TYPE 'X'
BACKER ROD AND SEALANT
PLYWOOD SHEATHING, S.S.D.
W.R.B.
GSM STUCCO STOP/J-MOLD, TYP.
SEALANT
24 GA GSM L-METAL, SETIN SEALANT
SAF, 9" WIDE
SAF, 6" WIDE
@ (N) DOOR: FRAME ANCHORPER MANUF. MIN. 3 PER JAMB,TYP.
EXTERIOR DOOR. SIM. FOROUTSWING DOOR
STEEL DOOR FRAME. (E) TOREMAIN @ GRADE. (N) AT 2FDECK LANDING
WEATHERSTRIPPING/SMOKESEAL
REF. DWG:
SCALE:
TITLE: DWG. NO:
ATTACHED TO:
DATE:
3" = 1'-0"
12/5/2014 2:43:48 PM
12/05/14
ASK1004.34
EXTERIOR DOOR JAMB AT STUCCO
U.C. SANTA CRUZ INFILL APMNTS REPAIRS7/A9.10
![Page 106: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND …...Lath & Plaster Installation Sequence Guide Pyatok Architects and Allana Buick & Bers, Inc. 12/5/2014 Notes: 1. Any conditions](https://reader030.vdocuments.us/reader030/viewer/2022040916/5e8ee207cc1c531cb377066e/html5/thumbnails/106.jpg)
CEMENT PLASTER STUCCO
(E) GYPSUM BOARD
LAP S.A.F. INTO DOOR R.O. AND UP WALLAS SHOWN.
PLYWOOD SHEATHING, S.S.D.
W.R.B., LAP OVER S.A.F. & HEADFLASHING, TYP.
(E) HEADER
GSM HEAD FLASHING WITH 30DEG. HEMMED EDGEAND INTEGRAL END CAPS. SEAL TO DOOR FRAME.EXTEND PAST DOOR FRAME MAX 3/8" ON EACH SIDE.SEE DETAIL 4
SEALANT
@ (N) DOOR: DOOR FRAME ANCHOR PER MANUF.
.OVERHANG OVER DOOR FRAME
9" SAF, OVER HEAD FLASHING, UNDER WRB
EXTERIOR DOOR. SIM. FOR OUTSWING DOOR
STEEL DOOR FRAME. (E) TO REMAIN @GRADE. (N) AT 2F DECK LANDINGS
WEATHERSTRIPPING/ SMOKESEAL
1/4
"
REF. DWG:
SCALE:
TITLE: DWG. NO:
ATTACHED TO:
DATE:
3" = 1'-0"
12/5/2014 2:43:48 PM
12/05/14
ASK1004.35
EXTERIOR DOOR HEAD AT STUCCO