Agricultural and Biosystems Engineering Technical Reports and White Papers Agricultural and Biosystems Engineering 5-1-2007 Tyson Broiler Ammonia Emission Monitoring Project: Final Report Robert T. Burns Iowa State University Hongwei Xin Iowa State University, [email protected] Richard S. Gates University of Kentucky Hong Li Iowa State University Steven J. Hoff Iowa State University, hoff[email protected] See next page for additional authors Follow this and additional works at: hp://lib.dr.iastate.edu/abe_eng_reports Part of the Agriculture Commons , Bioresource and Agricultural Engineering Commons , and the Poultry or Avian Science Commons is Report is brought to you for free and open access by the Agricultural and Biosystems Engineering at Iowa State University Digital Repository. It has been accepted for inclusion in Agricultural and Biosystems Engineering Technical Reports and White Papers by an authorized administrator of Iowa State University Digital Repository. For more information, please contact [email protected]. Recommended Citation Burns, Robert T.; Xin, Hongwei; Gates, Richard S.; Li, Hong; Hoff, Steven J.; Moody, Lara B.; Overhults, Douglas G.; and Earnest, John W., "Tyson Broiler Ammonia Emission Monitoring Project: Final Report" (2007). Agricultural and Biosystems Engineering Technical Reports and White Papers. 15. hp://lib.dr.iastate.edu/abe_eng_reports/15

Upload: others

Post on 16-Oct-2021

8 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Tyson Broiler Ammonia Emission Monitoring Project: Final

Agricultural and Biosystems Engineering TechnicalReports and White Papers Agricultural and Biosystems Engineering

5-1-2007

Tyson Broiler Ammonia Emission MonitoringProject: Final ReportRobert T. BurnsIowa State University

Hongwei XinIowa State University, [email protected]

Richard S. GatesUniversity of Kentucky

Hong LiIowa State University

Steven J. HoffIowa State University, [email protected]

See next page for additional authors

Follow this and additional works at: http://lib.dr.iastate.edu/abe_eng_reports

Part of the Agriculture Commons, Bioresource and Agricultural Engineering Commons, and thePoultry or Avian Science Commons

This Report is brought to you for free and open access by the Agricultural and Biosystems Engineering at Iowa State University Digital Repository. Ithas been accepted for inclusion in Agricultural and Biosystems Engineering Technical Reports and White Papers by an authorized administrator ofIowa State University Digital Repository. For more information, please contact [email protected].

Recommended CitationBurns, Robert T.; Xin, Hongwei; Gates, Richard S.; Li, Hong; Hoff, Steven J.; Moody, Lara B.; Overhults, Douglas G.; and Earnest,John W., "Tyson Broiler Ammonia Emission Monitoring Project: Final Report" (2007). Agricultural and Biosystems EngineeringTechnical Reports and White Papers. 15.http://lib.dr.iastate.edu/abe_eng_reports/15

Page 2: Tyson Broiler Ammonia Emission Monitoring Project: Final

Tyson Broiler Ammonia Emission Monitoring Project: Final Report

AbstractThis report describes the measurement methodologies and results of ammonia (NH3) emissions from twotypical Tyson broiler production houses located in western Kentucky. During this study, comprised over 13months and with six flocks per house, a total of 12 flocks of high quality emissions data were collected.Continuous measurement over a one-year period allowed for delineation of variations in emissions due toseasonal effects, animal growth cycles, and litter conditions. The study was led by Iowa State University (ISU),in collaboration with the University of Kentucky (UK). Data from this study add to and improve the nationalinventory on ammonia emissions from animal feeding operations (AFOs), especially broiler houses in thesoutheastern United States.

The two broiler houses monitored in this study are designated as Tyson 1-5 or T1-5 and Tyson 3-3 or T3-3 inthis report. The monitoring periods reported are 10/07/05 – 11/27/06 for T3-3 and 12/09/05 – 1/09/07 forT1-5. Note that ammonia monitoring began on 10/01/05 in both houses, but no birds were placed in T1-5until 12/09/05, explaining the different emissions reporting periods. The ammonia emissions reported in thisstudy are based on continuous measurements of ammonia concentration in the inlet and exhaust air and thecorresponding mechanical ventilation rate at each broiler house. Two Mobile Air Emissions Monitoring Units(MAEMUs), housing state-of-the-art measurement equipment, calibration accessories, and data acquisitionsystems, were developed at Iowa State University and used for this monitoring project.

Prior to the initiation of monitoring, a series of performance tests were conducted to confirm that themonitoring systems were working as designed and to determine representative locations for air samplingpoints. An EPA Category 1 Quality Assurance Project Plan (QAPP) – a substantial, 400-page document thatoutlines the methodologies for the project – was developed by the monitoring team. This Category 1 QAPPwas reviewed and approved by EPA. In addition, the project underwent and passed two technical audits: atechnical audit by Battelle personnel (contractors hired by EPA) confirming conformance of the projectimplementation with our QAPP, and an additional technical audit conducted by two nationally prominentagriculture air quality scientists.

DisciplinesAgriculture | Bioresource and Agricultural Engineering | Poultry or Avian Science

CommentsThe magnitude of ammonia emissions in this study is expressed as annual total on the basis of per bird, peranimal unit (AU, = 500 kg or 1100 lb live body weight) or per 1,000 birds marketed, daily mean, dailymaximum, flock total, during downtime (i.e., between flocks), and, with a 10% or less uncertainty. Theserespective values are: a) annual (365-d) emission (including downtime emissions) of 5.1 US tons per houseor 77.9 lb/1,000 birds marketed (or 35.4 g/bird marketed); b) 12-flock daily mean (± standard deviation)emission of 30.8 ± 20.0 lb/d-house or 0.91 ± 1.29 lb/AU-d; c) maximum grow-out daily emission of 67.4 lb/d-house for T1-5 and 78.2 lb/d-house for T3-3; d) mean (± SD) flock total emission of 1545 ± 298 lb/flock;and e) mean (± SD) downtime emission of 19.3 ± 18.2 lb/d-house. Flocks on new litter had a lower emissionrate of 27.2 ± 20.6 lb/d-house, as compared to 32.0 ± 19.6 lb/d-house for flocks on built-up litter. Ammoniaemission tended to be higher during the warmer weather. Bird age is the predominant influencing factor onammonia emissions. As such, an empirical equation has been established that relates ammonia emission to

This report is available at Iowa State University Digital Repository: http://lib.dr.iastate.edu/abe_eng_reports/15

Page 3: Tyson Broiler Ammonia Emission Monitoring Project: Final

bird age for the monitored broiler houses. Compared with the US EPA ammonia emission factor of 100 g/yr-bird (100 g/bird marketed), the magnitude of emission reported from this study is 35.4% of the EPA citedvalue. The use of an emission factor is not advised for systems such as broiler facilities in which substantialprogressive daily variation occurs as birds grow and then are removed repeatedly over a year. The use ofemission per 1000 birds marketed more realistically captures the events and allows for emission inventorytracking.

AuthorsRobert T. Burns, Hongwei Xin, Richard S. Gates, Hong Li, Steven J. Hoff, Lara B. Moody, Douglas G.Overhults, and John W. Earnest

This report is available at Iowa State University Digital Repository: http://lib.dr.iastate.edu/abe_eng_reports/15

Page 4: Tyson Broiler Ammonia Emission Monitoring Project: Final

Tyson Broiler Ammonia Emission Monitoring Project:

Final Report

Prepared by

Iowa State University and

University of Kentucky

Key Project Personnel: Robert Burns – Iowa State University

Hongwei Xin – Iowa State University

Rich Gates – University of Kentucky

Hong Li – Iowa State University

Steve Hoff – Iowa State University

Lara Moody – Iowa State University

Doug Overhults – University of Kentucky

John Earnest – University of Kentucky

Other Project Personnel:

Ross Muhlbauer Beth Ramey Tim Shepherd Guillerma Maia Carl Pederson Maria Amaral Zhiping Zhu Anshu Singh Jeremiah Davis Linda Stanton Heidi Anderson Marcello Brauer Brian Zelle Filipe Nascimineto Shafi Rahman Ricardo Vigodeiras Nurun Nahar Jamie Pursewell Lana Meyer Steve Trabue Adam Cook Ken Casey Jay Duncan

Date of Report: May 1, 2007

Page 5: Tyson Broiler Ammonia Emission Monitoring Project: Final

Executive Summary This report describes the measurement methodologies and results of ammonia (NH3) emissions from two typical Tyson broiler production houses located in western Kentucky. During this study, comprised over 13 months and with six flocks per house, a total of 12 flocks of high quality emissions data were collected. Continuous measurement over a one-year period allowed for delineation of variations in emissions due to seasonal effects, animal growth cycles, and litter conditions. The study was led by Iowa State University (ISU), in collaboration with the University of Kentucky (UK). Data from this study add to and improve the national inventory on ammonia emissions from animal feeding operations (AFOs), especially broiler houses in the southeastern United States.

The two broiler houses monitored in this study are designated as Tyson 1-5 or T1-5 and Tyson 3-3 or T3-3 in this report. The monitoring periods reported are 10/07/05 – 11/27/06 for T3-3 and 12/09/05 – 1/09/07 for T1-5. Note that ammonia monitoring began on 10/01/05 in both houses, but no birds were placed in T1-5 until 12/09/05, explaining the different emissions reporting periods. The ammonia emissions reported in this study are based on continuous measurements of ammonia concentration in the inlet and exhaust air and the corresponding mechanical ventilation rate at each broiler house. Two Mobile Air Emissions Monitoring Units (MAEMUs), housing state-of-the-art measurement equipment, calibration accessories, and data acquisition systems, were developed at Iowa State University and used for this monitoring project.

Prior to the initiation of monitoring, a series of performance tests were conducted to confirm that the monitoring systems were working as designed and to determine representative locations for air sampling points. An EPA Category 1 Quality Assurance Project Plan (QAPP) – a substantial, 400-page document that outlines the methodologies for the project – was developed by the monitoring team. This Category 1 QAPP was reviewed and approved by EPA. In addition, the project underwent and passed two technical audits: a technical audit by Battelle personnel (contractors hired by EPA) confirming conformance of the project implementation with our QAPP, and an additional technical audit conducted by two nationally prominent agriculture air quality scientists.

The magnitude of ammonia emissions in this study is expressed as annual total on the basis of per bird, per animal unit (AU, = 500 kg or 1100 lb live body weight) or per 1,000 birds marketed, daily mean, daily maximum, flock total, during downtime (i.e., between flocks), and, with a 10% or less uncertainty. These respective values are: a) annual (365-d) emission (including downtime emissions) of 5.1 US tons per house or 77.9 lb/1,000 birds marketed (or 35.4 g/bird marketed); b) 12-flock daily mean (± standard deviation) emission of 30.8 ± 20.0 lb/d-house or 0.91 ± 1.29 lb/AU-d; c) maximum grow-out daily emission of 67.4 lb/d-house for T1-5 and 78.2 lb/d-house for T3-3; d) mean (± SD) flock total emission of 1545 ± 298 lb/flock; and e) mean (± SD) downtime emission of 19.3 ± 18.2 lb/d-house. Flocks on new litter had a lower emission rate of 27.2 ± 20.6 lb/d-house, as compared to 32.0 ± 19.6 lb/d-house for flocks on built-up litter. Ammonia emission tended to be higher during the warmer weather. Bird age is the predominant influencing factor on ammonia emissions. As such, an empirical equation has been established

Tyson Broiler Ammonia Emission Monitoring ProjectFinal Report-Page 1

Page 6: Tyson Broiler Ammonia Emission Monitoring Project: Final

that relates ammonia emission to bird age for the monitored broiler houses. Compared with the US EPA ammonia emission factor of 100 g/yr-bird (100 g/bird marketed), the magnitude of emission reported from this study is 35.4% of the EPA cited value. The use of an emission factor is not advised for systems such as broiler facilities in which substantial progressive daily variation occurs as birds grow and then are removed repeatedly over a year. The use of emission per 1000 birds marketed more realistically captures the events and allows for emission inventory tracking.

Introduction Ammonia emissions from animal feeding operations (AFOs) have been estimated to represent the largest portion of the national ammonia emissions inventory in the United States (Battye et al. 1994). According to the most recent estimates by EPA (2005), broilers constitute 54% of poultry contributions to the U.S. ammonia inventory, and 14.8% of animal agriculture emissions. A comprehensive review by the National Academy of Science (NAS, 2003) regarding air emissions data pertaining to the U.S. AFOs concluded that such data are lacking for U.S. animal production conditions. The review called for collection of baseline emission data and development of process-based models to predict such air emissions. The objective of this study was to determine and report NH3 emissions based on continuous measurement of NH3 concentrations and fan flow data over a one-year period from two broiler houses representative of commercial broiler production in the southeastern United States. The emissions data presented in this report were collected using continuous ammonia emissions monitoring over a 13+ month period at two Tyson broiler production houses in western Kentucky.

Monitoring System Description Study Sites and Monitoring System Overview

Two broiler houses associated with Tyson Foods broiler operations in western Kentucky were monitored for NH3 emissions. The locations of the monitored facilities in Kentucky are shown in Figure 1, and the location of the specific house at each site is shown in aerial photos in Figure 2. The monitored broiler production houses use tunnel ventilation and static pressure controlled box air inlets along the sidewalls (Figure 3), which is representative of the typical production practices in terms of housing style (for example, tunnel ventilation) and environmental control strategy (for example, pancake brooder along with space heaters), bird management (for example, half-house brooding), and typical litter management and handling schemes (for example, de-caking houses between flocks and approximately annual litter removal).

To continuously quantify dynamic NH3 emissions from broiler production systems, an accurate and responsive measurement system was needed. The mass of NH3 emitted from a facility is the product of the NH3 concentration and volume of air exchanged through the facility. The use of intermittent ventilation by cycling ventilation fans off and on, especially when the birds were young, made it necessary to coincide in-house pollutant concentrations to periods of fan operation in order to properly calculate representative emissions.

Tyson Broiler Ammonia Emission Monitoring ProjectFinal Report-Page 2

Page 7: Tyson Broiler Ammonia Emission Monitoring Project: Final

The NH3 emission measurement system for this project used a photoacoustic NH3 analyzer (0-2000 ±0.2 ppm; INNOVA model 1412, INNOVA AirTech Instruments A/S, Denmark) in conjunction with a custom-fabricated multi-point sample acquisition system and calculation of exhausted air volumes based on fan curves obtained on-site using the Fan Assessment Numeration System (FANS) developed in the US (Gates et al., 2004).

Each broiler house had its own Mobile Air Emissions Monitoring Unit (MAEMU) that housed air pollutant and fan flow monitoring systems, and provided an environment-controlled instrument space as shown in Figure 4. Air sampling lines from the broiler house sampling points (representing the exhaust air streams) to the instrument trailer/analyzers were protected against in-line moisture condensation with insulation and temperature-controlled resistive heating cable. Fan operational status and building static pressure were both continuously monitored (1-second intervals). These data were used in conjunction with individual fan operation curves to calculate the flow rate exhausted by each fan during operation. A real-time data acquisition system (DAQ) program was developed using LabView 7 software (National Instruments, Corporation, Austin, TX) and used to acquire data, automate sampling location control, display real-time data, and deliver data and system operation status as shown in Figures 5 and 6. The system was connected to the internet via high-speed satellite.

Each MAEMU housed a gas sampling system, gas analyzers, environmental instrumentation, a computer, data acquisition system, and other peripheral devices and equipment needed for the study. The sampling periods were 13 and 13.6 months for Tyson 1-5 and Tyson 3-3, respectively. Gaseous samples were continuously collected and analyzed every 30 seconds, with every fourth concentration value used in the emission calculation. Using this approach gaseous emissions were sampled continuously on a 120-second interval. Emissions were calculated using the concentrations measured when the house ventilation system was in operation. The 13-plus months duration assured that the project characterized long-term emissions, hence the impacts of climatic conditions of different seasons and grow-out cycles (litter age and condition).

Tyson Broiler Ammonia Emission Monitoring ProjectFinal Report-Page 3

Page 8: Tyson Broiler Ammonia Emission Monitoring Project: Final

Tyson #1 House 5

Tyson #3 House 3

Figure 1. Broiler house air emission measurement sites in Kentucky.

Figure 2. Aerial photos indicating the locations of each monitored broiler house.

Tyson Broiler Ammonia Emission Monitoring ProjectFinal Report-Page 4

Page 9: Tyson Broiler Ammonia Emission Monitoring Project: Final

Figure 3. Tunnel ventilation fans and static pressure-controlled box air inlets representative of

typical southeastern broiler facilities.

Figure 4. Environmentally-controlled Mobile Air Emissions Monitoring Units (MAEMU).

Tyson Broiler Ammonia Emission Monitoring ProjectFinal Report-Page 5

Page 10: Tyson Broiler Ammonia Emission Monitoring Project: Final

Figure 5. Screen display of the broiler emissions monitoring program developed in LabView 7.

Figure 6. Photographical view of the positive-pressure sampling system used in the study.

Broiler House Characteristics

The two broiler houses each measured 13.1 m x 155.5 m (43 x 510 ft), were built in the early 1990s, and were located at two farm sites 40 miles apart in western Kentucky. The houses had insulated drop ceilings (about R19), box air inlets (15 x 66 cm or 6 x 26 inch) along the sidewalls (26 per sidewall), 26 pancake brooders (8.8 kW or 30,000 Btu/hr each), three space furnaces (65.9 kW or 225,000 Btu/hr each), four 91-cm (36-in) diameter sidewall exhaust fans spaced

Tyson Broiler Ammonia Emission Monitoring ProjectFinal Report-Page 6

Page 11: Tyson Broiler Ammonia Emission Monitoring Project: Final

about 36.6 m (120 ft) apart, and ten 123-cm (48-in) diameter tunnel fans. The 91-cm (36-in) fan (SW1) for minimum ventilation was located in the brood end of the houses away from the tunnel end. Two 24-m (80-ft) sections of evaporative cooling pads were located in the opposite end of the tunnel fans. The houses were also equipped with foggers for additional cooling, if needed. Rice hulls were used as litter bedding in both Tyson 1-5 and Tyson 3-3.

Flock Characteristics

The starting times of the ammonia emission monitoring were Oct 7, 2005 and Dec 9, 2005 for Tyson 3-3 and Tyson 1-5, respectively. After 365 days of continuous monitoring at each site, five flocks had been completed for each house and the sixth flocks were ongoing in the two houses (Table 1). The study was continued through the sixth flock at both houses. At the end of the monitoring, six flocks were monitored from each house and ending dates were Nov 27, 2007 and Jan 9, 2007 for Tyson 3-3 and Tyson 1-5, respectively. Each house had an initial placement of 25,800 Cobb-Cobb straight-run (mixed sex) broilers in winter and 24,400 in summer. The average grow-out periods were 51 d and 52 d for Tyson 1-5 and Tyson 3-3 respectively. A bird scale was placed in each house to continuously monitor bird weight. Bird mortality was also recorded, allowing for expression of emission on the basis of per bird or per 500 kg animal unit (AU). Both houses had new litter at the beginning of the monitoring. During the one-year period, one cleanout of the litter was performed for Tyson 1-5 on Aug 26, 2006 (after 4 flocks) and new bedding was placed on Aug 29, 2006; Tyson 3-3 did not have a litter cleanout during the monitoring period.

Tyson Broiler Ammonia Emission Monitoring ProjectFinal Report-Page 7

Page 12: Tyson Broiler Ammonia Emission Monitoring Project: Final

Table 1. Description of in-flock and between-flock information during the ammonia emission monitoring period.

Start Date End Date Flock name

House Condition

Litter condition

# of birds placed

Total # of days

Monitored # of days

12/9/05 1/28/06 Flock 1 Occupied New 25,810 51 51 1/29/06 2/13/06 Empty built-up 16 15 2/14/06 4/4/06 Flock 2 Occupied built-up 25,830 50 50 4/5/06 4/20/06 Empty built-up 16 14

4/21/06 6/9/06 Flock 3 Occupied built-up 22,995 50 50 6/10/06 6/21/06 Empty built-up 12 11 6/22/06 8/10/06 Flock 4 Occupied built-up 24,465 50 50

8/11/06 9/4/06 Empty New/built-up 25 24

9/5/06 10/25/06 Flock 5 Occupied new 25,695 51 51 10/26/06 11/16/06 Empty built-up 22 21

Tyso

n 1-

5

11/17/06 1/9/07 Flock 6 Occupied built-up 25,080 * 54 50

10/7/05 11/29/05 Flock 1 Occupied New 25,794 54 51 11/30/05 12/14/05 Empty built-up 15 14 12/15/05 2/3/06 Flock 2 Occupied built-up 25,180 51 51

2/4/06 2/19/06 Empty built-up 16 16 2/20/06 4/10/06 Flock 3 Occupied built-up 25,515 50 44 4/11/06 5/21/06 Empty built-up 41 39 5/22/06 7/11/06 Flock 4 Occupied built-up 24,450 51 48 7/12/06 7/27/06 Empty built-up 16 15 7/28/06 9/19/06 Flock 5 Occupied built-up 24,380 54 53 9/20/06 10/4/06 Empty built-up 15 14

Tyso

n 3-

3

10/5/06 11/27/06 Flock 6 Occupied built-up 25,778 54 53

* This flock had unexpected high mortality due to the improper vaccine procedure at the hatchery.

Monitoring System Specifics

Ammonia concentrations of the background and exhaust air were measured with an advanced photoacoustic NH3 analyzer (INNOVA model 1412, INNOVA AirTech Instruments A/S, Denmark), an EPA-accepted measurement equipment for AFO NH3 emission monitoring. This type of analyzer has been widely used by European scientists and recently used by U.S. scientists in AFO air emission studies (Fenyvesi, et al., 2001, Nicks et al., 2003, Guarino et al., 2003). These units proved to be accurate, responsive and stable over a one-year period of use. The INNOVA 1412 multi-gas analyzer was setup with a 1-second (s) sampling integration time and fixed flushing time: 2 s for the chamber and 3 s for the tubing; and the required time to complete one sampling cycle for NH3, carbon dioxide and dew-point temperature measurements was approximately 22 s. The response time of the analyzer to step changes in gas

Tyson Broiler Ammonia Emission Monitoring ProjectFinal Report-Page 8

Page 13: Tyson Broiler Ammonia Emission Monitoring Project: Final

concentrations was tested. The response time for the measured concentration to reach 98% of the calibration gas value (T-98) for the given NH3 calibration gas was 88 seconds using NH3 calibration gas of both 22.8 and 60.8 ppm (±2% accuracy) (Matheson Gas Products, Inc., Montgomeryville, PA). Thus, four measurement cycles (88 seconds) were required to reach the 98% response level for NH3. Using this approach, the first three readings were discarded and only the fourth reading was used for emission calculations. In April, 2006 hydrocarbon and nitrous oxide filters were added to the INNOVA 1412s. The time to complete a single measurement cycle increased from 22 seconds to 30 seconds. In turn this increased the time to complete four cycles from 88 seconds to 120 seconds. As before, only the fourth cycle measurements were used for emissions calculations.

Air samples were drawn from three locations in each house as well as from an outside location to provide ambient background data (Figure 7). One sampling location was near the primary minimum ventilation (36-in) sidewall fan (SW1) used for cold weather ventilation (in the brooding half of the house). The second sampling location was near the third sidewall (36-in) fan (SW3, non-brooding end). The third location was at the tunnel end (TE). The ambient sample location (A) was between the inlet boxes opposite of the sidewall with the exhaust fans. The quantity of gas in the background (inlet) air was subtracted from that in the exhaust air when calculating aerial emissions from the house.

Placement of the air sampling ports were as follows: for the two sidewall sampling locations, the sampling ports and temperature sensors were located 1.2 m (4.0 ft) away from the fan in the axial direction, 2.3 m (7.5 ft) in the radial direction, and 1 m (3 ft) above the floor. For the tunnel-end sampling location, the sampling port and temperature sensor were located at the center across the house (for example, 6.6 m or 21.5 ft from each sidewall) and 7.3 m (24.0 ft) from the end wall. Sampling locations and placement of the sampling ports were chosen to maximize representation of the air leaving the houses. Each sample inlet point was equipped with dust filters to keep large particulate matter from plugging the sample tubing, servo valves and ultimately the measurement instrument.

A positive pressure gas sampling system (PP-GSS) was used in the MAEMU for measurement of broiler house air emissions (Figure 8). The PP-GSS continuously pumps sample air from all locations using individual pumps. The sample air is bypassed when not analyzed. The schedules of sampling events and sequences are as follows. If the ventilation fans at the three in-house sampling locations (SW1-location 1, SW3-location 2 and TE-location 3) were all running, air samples from each location were collected sequentially via the controlled operation of the servo values of the PP-GSS. In this case, sampling/analysis sequence was SW1, SW3, and TE, and the cycle repeated. If fans at SW3 or TE were not running (for example, during half-house brooding), sample analysis was repeated for the SW1 location only, and the same was true for TE sampling when fans at SW1 and SW3 were not running (for example, during tunnel ventilation mode). Every two hours, air samples from the ambient (background) location were collected and analyzed for 8 minutes. The longer sample analysis time for the ambient point was to account for the longer response time of the instrument when measuring a large step change in gas concentration. Selection of the 2-hour interval for the analysis of the ambient

Tyson Broiler Ammonia Emission Monitoring ProjectFinal Report-Page 9

Page 14: Tyson Broiler Ammonia Emission Monitoring Project: Final

concentrations was due to the fact that the ambient conditions remained relatively constant, as compared to the in-house conditions. This arrangement helped maximize the number of data points collected from the exhaust air and thus provided more data for determination of house emissions.

Tyson 1-5 Drawing not to scale

Figure 7. Schematic layout of Tyson 1-5 and Tyson 3-3 broiler houses.

22’-9” 24’-2”

Brood Curtain Evaporative Coolers

SW1 SW2 SW3 SW4

22’

12’

9 7 5 3 1 10 8 6 4 2

Fan Numbers

Feed Bin Trailer Gravel Pad

Ditch

T, T,

105’ 120’98’ 135’52’

5’

235’ 15’

ControlRoom

5’

8’

510’ (outside)

277’

52’

80’

Note: Curtain aligns with end of Feed Bin Pad.

T, RH and B

T

RH = Relative Humidity sample point = Pressure Differential Sampling Point

= Air sampling point = 36” sidewall fan

= 48” fan

T = Temperature sample point = Ambient air sampling point

B = Barometric pressure sample point = TEOM sampling point

43’

Tyson 3-3 Drawing not to scale

Brood Curtain Evaporative Coolers

SW1 SW2 SW3 SW4

24’

12’

2 4 6 8 10 1 3 5 7 9

Fan Numbers

Feed Bin

Trailer

Extended gravel

ControlRoom

T, T,

T

120’ 58’

135’120’83’ 24’-7” 22’-5”52’

5’

510’ (outside)

80’

235’-6”

Conc Pad

10’

15’

8’ 14’

284’-6”

Note: Curtain aligns with end of Feed Bin Pad.

RH = Relative Humidity sample point = Pressure Differential Sampling Point

= Air sampling point = 36” sidewall fan

= 48” fan

T = Temperature sample point = Ambient air sampling point

B = Barometric pressure sample point = TEOM sampling point

43’

T, RH and B

Tyson Broiler Ammonia Emission Monitoring ProjectFinal Report-Page 10

Page 15: Tyson Broiler Ammonia Emission Monitoring Project: Final

Location 3

Location 2

Location 1

Ambient air

P 4

P 3

P 2

P 1

M1

S1

S5

S2

S3

S4

S6

S7

S8

Exhaust

Compact Fieldpoint DAQ

Filter Filter

Red line: heated line

ExhaustM2

INNOVA 1412

API 101E

VIG 200

Flow meter

P: PumpM: ManifoldS: Solenoid

S1- 4: Normal Closed S5 -8:Normally Open

Location 3

Location 2

Location 1

Ambient air

P 4

P 3

P 2

P 1

M1

S1

S5

S2

S3

S4

S6

S7

S8

Exhaust

Compact Fieldpoint DAQ

Filter Filter

Red line: heated line

ExhaustM2

INNOVA 1412

API 101E

VIG 200

Flow meter

P: PumpM: ManifoldS: Solenoid

S1- 4: Normal Closed S5 -8:Normally Open

Figure 8. Schematic representation of the positive pressure gas sampling system (PP-GSS) used in

the MAEMU for measurement of broiler house air emissions.

The PP-GSS continuously collected air from all locations with location-specific pumps. Teflon tubing (Fluorotherm FEP tubing) of 0.95-cm (3/8-inch) o.d. and 0.64-cm (1/4-inch) i.d. was used to deliver the sample air. The sample air was bypassed when not analyzed. Use of individual pumps to continuously draw air from the respective sampling locations reduced line-purging time and eliminated possible cross-location residual effect, especially between ambient/background air and exhaust air samples. The choice of sequential sampling was based on the assumption that any concentration changes at the given location during the two adjacent measurements (maximum of 360 seconds) followed a linear pattern. Hence, linear interpolation from the two adjacent measured values was used to determine intermediate values for the location, as needed. The use of one sampling location at the tunnel fan end of the house assumed good mixing of air and thus uniform distribution of the aerial concentrations during tunnel ventilation conditions. Examination of ammonia concentrations across the house in this section, through concurrent measurements using four INNOVA 1412 analyzers, confirmed the validity of this assumption. Moreover, it was assumed and validated that the vertical stratifications in aerial concentrations were negligible when the exhaust fans were in operation. Incidentally, appreciable vertical stratifications existed when the fans were off. Only samples collected when fans were operating were used for the calculation of ammonia emissions from the broiler houses.

Ventilation rates of the houses were measured using the following procedure. First, all the exhaust fans were calibrated in situ, individually and in combined operational stages, with a state-of-the-art fan assessment numeration system (FANS) to obtain the actual ventilation

Tyson Broiler Ammonia Emission Monitoring ProjectFinal Report-Page 11

Page 16: Tyson Broiler Ammonia Emission Monitoring Project: Final

curves (airflow rate vs. static pressure) (Gates et al., 2004). This calibration was essential to the accurate measurement of the house ventilation rate because actual fan airflow rates can vary in excess of 25% from one another and from the nominal values supplied by the fan manufacturer (Figure 9). The deviation arises from the field operational conditions that differ drastically from those under which the default values were established, for example, loose motor belts, and dirty shutter or fan blades. After the actual airflow curves were established for all of the exhaust fans and their combinations, runtime of each fan was monitored and recorded continuously using an inductive current switch (with analog output) attached to the power supply cord of each fan motor (Figure 10). Analog output from the current switches was connected to the compact Fieldpoint modules. Concurrent measurement of the house static pressure was made with two static pressure sensors (Model 264, Setra, Boxborough, MA), each for half of the house. While the pressure differential was not expected to differ at the two locations, two sensors were used to provide redundancy in this critical measurement. Summation of airflows from the individual fans during each monitoring cycle or sampling interval produced the overall house ventilation rate. This method of determining dynamic ventilation rates of mechanically ventilated animal confinement has been successfully used in recent AFO air emission studies in the United States.

Variation in airflow rates among 0.9-m (36 inch) and 1.2-m (48 inch) fans, as

measured with the FANS

0

2000

4000

6000

8000

10000

12000

14000

16000

18000

0 0.02 0.04 0.06 0.08 0.1 0.12 0.14 0.16 0.18Static Pressure, inch WC

Fan

airf

low

rate

, cfm

48" fans

36" fans

1 cfm = 1.7 m3/hr

1 inch WC = 248.9 pa

Figure 9. Variation in fan airflow rates among the 36-in and 48-in fans in Tyson 1-5 broiler house.

Tyson Broiler Ammonia Emission Monitoring ProjectFinal Report-Page 12

Page 17: Tyson Broiler Ammonia Emission Monitoring Project: Final

Fan runtime sensor

Fan calibration by FANS unit

Figure 10. Photographical views of the fan operational sensor and the FANS unit.

Indoor and outdoor temperature and relative humidity (RH) were measured with robust and stable temperature (Type T thermocouple, Cole-Parmer, Vernon Hills, IL) and RH probes (HMW60, Vaisala, Woburn, MA) that were connected to the PC-based data acquisition system (DAQ). In addition, portable temperature/RH loggers were used as back-ups. Analog output of the static pressure sensors was also connected to the DAQ.

All the variables of NH3 concentration, fan runtime, static pressure, air temperature and RH were continuously measured and recorded at one-second interval throughout the one-year study period. The collected raw data were archived and backed up each day. Emission Rate Determination

Ammonia emission rate (ER) from a broiler house to the atmosphere is the difference between the quantity of ammonia leaving the house and the quantity of ammonia entering the house. The relationship of ER to NH3 concentration of inlet and exhaust air and building ventilation rate may be expressed as following:

[ ]std

a

a

std

m

m

ei

i

eee P

PTT

VwNHNHQER ××××⎟⎟

⎞⎜⎜⎝

⎛−= −

=∑ 6

3

133 10][

ρρ

[1]

where ER = NH3 emission rate for the house (g hr-1 house-1)

Qe = ventilation rate of the portion of the house at location “e” (SW1, SW3 or TE) at

field temperature and barometric pressure (m3 hr-1 house-1)

[NH3]i = NH3 concentration of incoming house ventilation air, parts per million by volume

(ppmv)

[NH3]e = NH3 concentration of exhaust house ventilation air of the portion of the house

at location “e” (ppmv)

wm = molar weight of NH3, 17.031 g mole-1

Tyson Broiler Ammonia Emission Monitoring ProjectFinal Report-Page 13

Page 18: Tyson Broiler Ammonia Emission Monitoring Project: Final

Vm = molar volume of NH3 gas at standard temperature (0°C) and pressure (1

atmosphere) (STP), 0.022414 m3 mole-1

Tstd = standard temperature, 273.15 K

Ta = absolute house temperature, (°C+273.15) K

Pstd = standard barometric pressure, 101.325 kPa

Pa = atmospheric barometric pressure for the site elevation, kPa

ρe = air density at exhaust fan location “e”, kg dry air m-3 moist air

ρi = air density at outside conditions, kg dry air m-3 moist air

As can be seen from equation [1] and description of the variables shown above, multiple measurements were required to determine the ammonia emission rate.

System Checks

Accuracy is defined as the degree of agreement between an observed value and an accepted reference value and includes a combination of random error (precision) and systematic error (bias). In this study, the following accuracy checks were implemented:

• Gas analyzers • Exhaust fan flow rates • Static pressure sensors • Temperature and relative humidity sensors • Barometric pressure sensor • PP-GSS leakage and pump flow rates

The response times of the analyzers were tested in the lab prior to installation in the field. The actual on-site performance of the sampling system was further tested. Tests were performed by injecting ammonia span gas into the in-house sampling port of the longest sampling line (tunnel end, see Figure 11). The results of INNOVA 1412 analyzers from both houses are shown in Figures 12 and 13. For both sampling systems, the fourth ammonia concentration readings (30 s X 4=120 s) reached 96% and 97% of the span concentration.

Tyson Broiler Ammonia Emission Monitoring ProjectFinal Report-Page 14

Page 19: Tyson Broiler Ammonia Emission Monitoring Project: Final

Figure 11. Picture of span gas injection at the in-house sampling point.

INNOVA 1412Tyson 1-5_Tunnel

0

65

83

22

1512

9 10 10 8

100 100 1011009897 9997

94

0

20

40

60

80

100

0:00 0:30 1:00 1:30 2:00 2:30 3:00 3:30 4:00 4:30 5:00 5:30 6:00 6:30 7:00

Time,min:sec

Perc

enta

ge,%

0

5

10

15

20

25

NH 3

Con

cent

ratio

n, p

pm

Figure 12. Response time check of the sampling system and INNOVA analyzer at Tyson 1-5.

Tyson Broiler Ammonia Emission Monitoring ProjectFinal Report-Page 15

Page 20: Tyson Broiler Ammonia Emission Monitoring Project: Final

INNOVA 1412Tyson 3-3_Tunnel

0

75

89

94

100999997

10096

0

20

40

60

80

100

0:00 0:30 1:00 1:30 2:00 2:30 3:00 3:30 4:00 4:30 5:00 5:30Time, min:sec

Perc

enta

ge,%

0

5

10

15

20

25

NH 3

Con

cent

ratio

n, p

pm

Figure 13. Response time check of the sampling system and INNOVA analyzer at Tyson 3-3.

In addition to span gas challenge of the entire system at the farthest in-house sampling location, tests were conducted to compare the readings of a calibrated INNOVA 1412 analyzer located inside the monitoring trailer with three other calibrated INNOVA 1412 analyzers located at three sampling locations in the broiler house (SW1, SW3 and TE). The three in-house INNOVA 1412 analyzers continuously took samples during the entire testing period (Figure 14). All INNOVA 1412 analyzers were synchronized and calibrated with the same NH3 calibration gases before the test.

Figure 14. One of the three in-house INNOVA analyzers used to compare readings to its

counterpart inside the MAEMU.

Tyson Broiler Ammonia Emission Monitoring ProjectFinal Report-Page 16

Page 21: Tyson Broiler Ammonia Emission Monitoring Project: Final

At Tyson 1-5, the number of sampling cycles for the INNOVA in the MAEMU per location was set to 4, 6 or 8 cycles per location to test the response time effect. The NH3 readings by the INNOVA 1412 in the MAEMU were compared with the respective readings by the three in-house INNOVA 1412s (Figure 15). Only the last readings from the MAEMU in each sampling cycle for each location were compared with the most recent readings from the INNOVAs in the house. Five pairs of readings for each sampling cycle setting at each location were taken. A two-way ANOVA test was used for the statistic analysis. There was neither a sampling number effect nor location effect (P = 0.37). Table 2 provides a comparison of continuous in-house NH3 readings with those obtained from location cycling by the MAEMU INNOVA at 4, 6, and 8 sampling iterations for Tyson 1-5 (unit: ppm). The results indicate that the NH3 reading in the MAEMU matched the reading in the house at all three locations and there was no difference in using 4, 6 and 8 sampling iterations at each location. Hence, four sampling iterations were chosen to maximize the sampling frequency for each location. Because the fan operation period could be as short as 30 seconds while the birds were young and during cold weather, it was essential to quickly move between the sample locations to capture the temporal variability in ammonia concentration arising from the intermittent (on/off) operation of the fans. Since the NH3 reading in the MAEMU matched the reading in the house at each location, it indicated that there was no leakage in the entire sampling system. The same test was conducted for Tyson 3-3 and yielded the same results.

During weekly field visits, each sampling line was checked by connecting a flow meter at the pump-end and blocking the in-house sampling port (Figure 16). If the flow meter read zero, it indicated no leakage in the sampling line under the negative pressure (from the in-house sampling port to the corresponding sampling pump inside the MAEMU). No leakage was detected throughout the monitoring period.

Table 2. Comparison of in-house NH3 readings by respective INNOVA analyzers with those obtained from location cycling by the INNOVA analyzer inside the MAEMU.

NH3(in-house) – NH3(MAEMU) For sampling locations of (ppm) P=0.37 No. of sampling

Iterations SW1 SW3 Tunnel Mean SD 4 0.72 0.20 0.31 0.41a 0.65 6 0.26 0.08 -0.19 0.05a 0.37 8 0.18 -0.02 0.46 0.20a 0.39 Mean 0.39 b 0.09 b 0.19 b Total mean 0.22 SD 0.66 0.33 0.40 Total SD 0.50

*Column or row means with the same superscript letter are not significantly different (P>0.10)

Location Mean (ppm) SD

SW1 0.45 a 0.46 SW3 0.03 a 0.83 Tunnel -0.27 a 0.98 Total 0.03 0.82

*Column means with the same superscript letter are not significantly different (P>0.10)

Tyson Broiler Ammonia Emission Monitoring ProjectFinal Report-Page 17

Page 22: Tyson Broiler Ammonia Emission Monitoring Project: Final

Comparison and Sample Frequency Test at Tyson 15, Feb 8 2006

0

5

10

15

20

25

30

13:12 13:40 14:09 14:38 15:07 15:36 16:04

Time, hr:min

Am

mon

ia C

once

ntra

tion,

ppm

NH3_sw1_TrailerNH3_sw3_TrailerNH3_T_TrailerNH3-sw1NH3-sw3NH3-Tunnel4 samples per location

8 samples per location

6 samples per location

Figure 15. Comparison of ammonia readings from the MAEMU and in-house INNOVAs.

Figure 16. Schematic representation of the gas sampling system integrity (leakage) check.

Flow meter 2

Pump Flow meter 1

GSS Board Sampling tubing

Quality Assurance/Quality Control of Data Collection and Analysis

Strict Quality Assurance/Quality Control (QA/QC) procedures were followed throughout the data collection and data analysis processes. All measurement instruments underwent initial checks and calibrations, followed by regular operational checks and follow-up calibrations as dictated

Tyson Broiler Ammonia Emission Monitoring ProjectFinal Report-Page 18

Page 23: Tyson Broiler Ammonia Emission Monitoring Project: Final

by the QAPP. The frequency of such check/calibration depended on the instrument. For instance, the NH3 gas analyzer was checked with calibration gases weekly or semi-weekly, even though our past experience had indicated that this type of photo-acoustic NH3 analyzer has excellent stability. Calibration gases were certified with concentration of 22.6, 22.8, or 25 ppm ammonia (Balanced in air, certified grade with 2% accuracy, Matheson Tri-gas, PA). The INNOVA 1412 analyzers were checked once a week before February 2006 and then were checked twice a week after February 2006 to meet our data quality goal. The QC standard of instrument calibration is 5%. Based on the regular check results, the INNOVA 1412 analyzers were calibrated twice at Tyson 1-5 and three times at Tyson 3-3 during the grow-out periods. Internal technical system performance evaluations were performed between flocks.

The broiler houses had approximately two weeks of downtime between flocks. However, the downtime at Tyson 3-3 was 41 days after the first flock due to change of the managerial personnel at the site. During each downtime, ISU and UK project personnel conducted a thorough internal technical systems audit at each site. This audit included a visual inspection of all system components, and a flow check at each of the four sample points. During the system performance evaluation, the INNOVA 1412 analyzers were recalibrated. All temperature sensors were checked against a certified thermometer for every flock. The RH sensors and pressure sensors were checked or calibrated against a calibrated sensor or a RH sensor calibration kit (HMK 15, Vaisala, Woburn, MA) every six months. If the check result fell outside of 5% QC standard, recalibration would be performed and the corresponding data would be corrected, following a linear relationship between values from the previous check and current check.

The performance curves of the ventilation fans were checked after each flock. All exhaust fans were cleaned before the start of a new flock. An uninterrupted power supply (UPS) was used for the DAQ system to avoid loss of data due to power outage.

Two external technical systems audits were conducted by independent personnel during the project. Battelle personnel (commissioned by EPA) audited the systems on September 25-26, 2006 and agricultural air monitoring experts, Drs. Larry Jacobson and David Parker, (commissioned by Iowa State University) audited the systems on January 8 – 10, 2007. Both audits found that the QAPP was being fully and successfully implemented at both sites. As described in the QAPP, a data processing program was run daily to process the data collected on the previous day. This program calculated data completeness and automatically flagged out-of-range data. ISU project personnel reviewed the flagged data within two working days to confirm that the data were either invalid and should be excluded or valid and should be kept. To avoid errors introduced into determination of average values due to partial data days, which would result in biased time weights, only complete-data days (CDD) that included over 75% valid data were used in calculating average daily means (ADM). Based on the on-site surveillance and daily data flagging/review, daily data completeness for each variable was calculated.

Uncertainty Analysis of Emission Rate

Tyson Broiler Ammonia Emission Monitoring ProjectFinal Report-Page 19

Page 24: Tyson Broiler Ammonia Emission Monitoring Project: Final

Component error analysis is used to quantify uncertainty when a quantity such as daily emission rate is calculated from multiple measurements, each with its own degree of accuracy or uncertainty. A component error analysis (Doeblin, 1990) provides statistical meaning to a statement on the magnitude of error in the calculation of daily emission rate. This analysis had been performed for an earlier project that measured broiler house ammonia emissions and documented in a copyrighted Ph.D. dissertation (Casey, 2005) and a manuscript in preparation (Casey et al., 2007). The uncertainty analysis of ER for this study is described in detail in the project QAPP. The resultant ER uncertainty was 10% or less based on the accuracies of the associated measurement components and operating ranges for ventilation fans. Consequently, data quality objectives (DQOs) and measurement quality objectives (MQOs) were developed in the QAPP to guide the achievement of 10% or less ER uncertainty.

Results and Discussion Data Completeness

“Data completeness is a measure of the amount of valid data obtained from a measurement system, expressed as a percentage of the number of valid measurements that should have been collected” (USEPA, 2002. EPA Guidance for Quality Assurance Project Plans. EPA QA/G-5). In this study, a data completeness goal of 75% of the scheduled sampling was established. The data completeness is primarily affected by unpredictable field events, including instrument malfunction, power outages due to adverse weather, and broiler house maintenance. When any of these events occurred, the corresponding emission data were flagged. The starting times of ammonia emission monitoring were Oct. 7, 2005 and Dec. 9, 2005 for Tyson 3-3 and Tyson 1-5, respectively. By the one-year mark (Oct. 6, 2006 for Tyson 3-3 and Dec. 8, 2006 for Tyson 1-5), five full flocks had been monitored at each site; the 6th flock had been monitored for 22 days for Tyson 1-5 and two days for Tyson 3-3. For the 365-d annual emission calculation, the CDDs to date are 355 out of 365 days (97.2% data completeness) and 346 out of 365 days (94.8% data completeness), respectively, for Tyson 1-5 and Tyson 3-3. Therefore, a total of 701 house-day emission data were used for the analysis of the annual emission. The monitoring was continued through the sixth flock at both houses for a full set of the sixth flock data; the ending dates of the monitoring were Nov 27, 2006 and Jan 9, 2007 for Tyson 3-3 and Tyson 1-5, respectively. By the end of the six flocks, the CDDs were 387 out of 397 days (97.5% data completeness) for Tyson 1-5 and 398 out of 417 days (95.4% data completeness) for Tyson 3-3. The 785 house-day (12 flocks) emission data were used for the emission rate of daily mean, daily maximum, flock total, and during downtime. The complete-data days (CDD) for each flock and in-between are summarized in Table 1.

Diurnal Variation of Ammonia Emission Rate

The ammonia ER is a combination of the difference in ammonia concentration between the exhaust air and the inlet air and building ventilation rate (VR). The diurnal variation of ammonia ER, concentration and VR, expressed as hourly averages for two growth periods on cold and warm days are shown in Figure 17. The hourly ammonia ER on the warm days had a clear

Tyson Broiler Ammonia Emission Monitoring ProjectFinal Report-Page 20

Page 25: Tyson Broiler Ammonia Emission Monitoring Project: Final

diurnal pattern following the VR. During cold weather, the hourly ammonia ER had less variation. The coefficient of variation (CV) of hourly ER on Day 38 of Flock 4 for Tyson 1-5 on July 29, 2006 was 16%. In contrast, the CV on Day 39 of Flock 6 for Tyson 1-5 was 6.2% on December 25, 2006. The CV of hourly ER on Day 5 for flock 5 and flock 6 for Tyson 1-5 was 79.6% and 8.1%, respectively. The considerable diurnal variation in flock 5 coincided with a warm day and the lower CV in flock 6 corresponded to a cold day with only minimum ventilation. Liang et al. (2005) reported similar daily ammonia ER variation trends for laying hen houses.

Tyson Broiler Ammonia Emission Monitoring ProjectFinal Report-Page 21

Page 26: Tyson Broiler Ammonia Emission Monitoring Project: Final

Tyson1-5_Flock6_Day 5 (11/21/2006)

0

5

10

15

20

25

30

35

40

45

50

0:00 4:00 8:00 12:00 16:00 20:00 0:00Time, hr:min

NH

3 Con

cent

ratio

n, p

pm

0

20000

40000

60000

80000

100000

120000

140000

VR, C

FM/h

ouse

NH3 concentration (sw1),pppmNH3 concentration (sw3),ppmVR, cfm

Tyson1-5_Flock6_Day 5 (11/21/2006)

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

0:00 4:00 8:00 12:00 16:00 20:00 0:00Time, hr:min

NH

3 ER

, lb/

hr-h

ouse

Bird body weight=0.168 lbBird age=5-d

CV=8.1%

Tyson1-5_Flock5_Day 5 (9/09/2006)

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

4.5

5.0

0:00 4:00 8:00 12:00 16:00 20:00 0:00Time, hr:min

NH

3 Con

cent

ratio

n, p

pm

0

20000

40000

60000

80000

100000

120000

140000

VR, C

FM/h

ouse

NH3 concentration (sw1),pppm

NH3 concentration (sw3),ppm

VR, cfm

Tyson1-5_Flock5_Day 5 (9/09/2006)

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

0:00 4:00 8:00 12:00 16:00 20:00 0:00Time, hr:min

NH

3 ER

, lb/

hr-h

ouse

Bird body weight=0.221 lbBird age=5-d

CV=79.6%

Tyson1-5_Flock4_Day 38 (7/29/2006)

0

5

10

15

20

25

30

35

40

45

50

0:00 4:00 8:00 12:00 16:00 20:00 0:00Time, hr:min

NH

3 Con

cent

ratio

n, p

pm

0

20000

40000

60000

80000

100000

120000

140000

VR, C

FM/h

ouse

NH3 concentration(Tunnel),ppmVR, cfm

Tyson1-5_Flock4_Day 38 (7/29/2006)

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

4.5

5.0

0:00 4:00 8:00 12:00 16:00 20:00 0:00Time, hr:min

NH

3 ER

, lb/

hr-h

ouse

Bird body weight=4.156 lbBird age=38-d

CV = 16%

Tyson1-5_Flock6_Day 39 (12/25/2006)

0

5

10

15

20

25

30

35

40

45

50

0:00 4:00 8:00 12:00 16:00 20:00 0:00Time, hr:min

NH

3 Con

cent

ratio

n, p

pm

0

20000

40000

60000

80000

100000

120000

140000

VR, C

FM/h

ouse

NH3 concentration (sw1),pppmNH3 concentration (sw3),ppmVR, cfm

Tyson1-5_Flock6_Day 39 (12/25/2006)

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

4.5

5.0

0:00 4:00 8:00 12:00 16:00 20:00 0:00Time, hr:min

NH

3 ER

, lb/

hr-h

ouse

Bird body weight=4.04 lbBird age=39-d

CV=6.2%

Figure 17. Diurnal patterns of exhaust ammonia concentration, ventilation rate (VR), and ammonia

emission from Tyson 1-5.

Tyson Broiler Ammonia Emission Monitoring ProjectFinal Report-Page 22

Page 27: Tyson Broiler Ammonia Emission Monitoring Project: Final

Emission Rate

Figures 18 and 19 provide the daily ammonia ER for the two houses for the entire monitoring period with six full flocks and downtime between flocks. The daily ER (lb/d-house) varied from 0 to 98.6 lb/d-house. When the houses were occupied by birds, the highest ER was 67.4 and 78.2 lb/d-house for Tyson 1-5 and Tyson 3-3, respectively. The highest daily emission of 98.6 lb/d-house occurred at Tyson 1-5 between flock 2 and flock 3. The highest emission happened on April 6, 2006 when the litter was disturbed during litter-decaking operation (see Figure 18 c). Note that the emissions between the vertical dashed lines in Figures 18 and 19 represent periods between flocks when no birds were in the houses (i.e., downtime).

The ammonia ERs (0.55 ± 0.42 lb/d-house) from the flocks with new litter were significantly less (P<0.001) than those (13.36 ± 5.88 lb/d-house) with built-up litter during the first 6 days of grow-out. After that, ERs with new litter began to increase rapidly with bird age. For the flocks with built-up litter, the ammonia ERs were relatively stable during the first 2-3 weeks and then increased. The flocks with new litter did not show significantly higher ER than those with built-up litter (P=0.86) when the bird age was 7-d or older. There was a trend that the ERs reached the peak after 5-6 weeks and tended to stabilize through the end of the flock. During the grow-out periods, the ERs for the three flocks on new litter was 27.2 ± 20.6 lb/d-house, which is significantly lower than 32.0 ± 19.6 lb/d-house for the nine flocks raised on built-up litter. The ERs of all flocks varied from 25.7 lb/d-house to 37.7 lb/d-house, except flock 6 in Tyson 1-5 (Table 3). Flock 6 in Tyson 1-5 had over 40% of cumulative mortality by the end of the flock due to a vaccination complication, leading to a much lower ER of 18.6 lb/d-house. The average ER for Tyson 1-5 over the six flocks was 27.6 ± 17.2 lb/d-house which is significantly lower (from statistical standpoint) than 34 ± 21.9 lb/d-house for Tyson 3-3 (P=0.01). The average NH3 ER for Tyson 3-3 downtime between flocks was 13.9 ± 15.0 lb/d-house. In contrast, the average ER at Tyson 1-5 for downtime between flocks was 26.2 ± 19.5 lb/d-house. Tyson 1-5 had two flocks with new litter while Tyson 3-3 only had one flock with new litter. Flock 4 in both houses and flock 5 in Tyson 3-3 had higher ERs than the other flocks under the warm weather conditions when the house ventilation system was in the tunnel mode to keep the birds cool. The average ER of all 12 flocks was 30.8± 20.0 lb/d-house.

Tyson Broiler Ammonia Emission Monitoring ProjectFinal Report-Page 23

Page 28: Tyson Broiler Ammonia Emission Monitoring Project: Final

Tyson1-5

0

40000

80000

120000

160000

200000

12/9/05 1/8/06 2/7/06 3/9/06 4/8/06 5/8/06 6/7/06 7/7/06 8/6/06 9/5/06 10/5/06 11/4/06 12/4/06 1/3/07

Dai

ly A

vera

ge V

R, C

FM/h

ouse

Flock1 Flock2 Flock3 Flock4 Flock5 Flock6

(a)New-bedding

New-bedding

0

10

20

30

40

50

60

70

80

90

100

12/9/05 1/8/06 2/7/06 3/9/06 4/8/06 5/8/06 6/7/06 7/7/06 8/6/06 9/5/06 10/5/06 11/4/06 12/4/06 1/3/07

Dai

ly A

vera

ge T

outs

ide, o F (b)

0

10

20

30

40

50

60

70

80

90

100

12/9/05 1/8/06 2/7/06 3/9/06 4/8/06 5/8/06 6/7/06 7/7/06 8/6/06 9/5/06 10/5/06 11/4/06 12/4/06 1/3/07

Am

mon

ia E

R, l

b/d-

hous

e

Flock1 Flock2 Flock3 Flock4 Flock5 Flock6

(c)New-bedding

New-bedding

Figure 18. Daily ammonia emission, ventilation rate and outside temperature over the six flocks for

Tyson 1-5.

Tyson Broiler Ammonia Emission Monitoring ProjectFinal Report-Page 24

Page 29: Tyson Broiler Ammonia Emission Monitoring Project: Final

Tyson Broiler Ammonia Emission Monitoring ProjectFinal Report-Page 25

Figure 19. Daily ammonia emission, ventilation rate and outside temperature over the six flocks for

Tyson 3-3.

0

10

20

30

40

50

60

70

80

90

100

10/7/05 11/6/05 12/6/05 1/5/06 2/4/06 3/6/06 4/5/06 5/5/06 6/4/06 7/4/06 8/3/06 9/2/06 10/2/06 11/1/06

Dai

ly A

vera

ge T

outs

ide, o F (b)

0

10

20

30

40

50

60

70

80

90

100

10/7/05 11/6/05 12/6/05 1/5/06 2/4/06 3/6/06 4/5/06 5/5/06 6/4/06 7/4/06 8/3/06 9/2/06 10/2/06 11/1/06

Am

mon

ia E

R, l

b/d-

hous

e

Flock1 Flock2 Flock3 Flock4 Flock5 Flock6

(c)New-bedding

Tyson3-3

0

40000

80000

120000

160000

200000

10/7/05 11/6/05 12/6/05 1/5/06 2/4/06 3/6/06 4/5/06 5/5/06 6/4/06 7/4/06 8/3/06 9/2/06 10/2/06 11/1/06

Dai

ly A

vera

ge V

R, C

FM/h

ouse

Flock1 Flock2 Flock3 Flock4 Flock5 Flock6

(a)New-bedding

Page 30: Tyson Broiler Ammonia Emission Monitoring Project: Final

ER, lb/d-house ER, g/bird-d ER, g/AU-d [b]

Starting

time Ending time

Flock name

House Condition [ a ]

Cumulative Emission, lb/house(s) Mean S.D Max Min Mean S.D Max Min Mean S.D Max Min

12/9/05 1/28/06 Flock 1 O 1362 26.7 18.5 52.9 0.3 0.48 0.34 0.96 0.01 207.2 114.6 411.9 21.11/29/06 2/13/06 E 222 14.8 7.2 30.1 6.5 - - - - - - - -2/14/06 4/4/06 Flock 2 O 1424 28.5 20.8 61.7 4.9 0.51 0.38 1.11 0.09 316.5 302.0 1924 123.14/5/06 4/20/06 E 574 41.0 26.8 98.6 12.7 - - - - - - - -

4/21/06 6/9/06 Flock 3 O 1424 28.5 14.8 62.5 6.9 0.59 0.31 1.29 0.14 457.9 480.9 2725 106.76/10/06 6/21/06 E 407 37.0 8.8 51.2 26.5 - - - - - - - -6/22/06 8/10/06 Flock 4 O 1883 37.7 14.7 61.4 18.0 0.71 0.28 1.16 0.34 702.5 945.6 5515 117.98/11/06 9/4/06 E 432 18.0 20.9 67.4 0.0 - - - - - - - -9/5/06 10/25/06 Flock 5 O 1312 25.7 17.1 50.2 0.7 0.47 0.31 0.91 0.01 207.5 78.8 361.4 54.1

10/26/06 11/16/06 E 433 20.6 14.5 42.6 0.0 - - - - - - - -11/17/06 1/9/07 Flock 6 [c] O 931 18.6 11.1 46.5 4.8 0.54 0.38 1.52 0.13 605.3 1108 5036 126.9

Tyson 1-5 between flocks E 2068 26.2 19.5 98.6 0.0 - - - - - - - -

Tyso

n1-5

Tyson 1-5 all 6 flocks O 8335 27.6 17.2 67.4 0.3 0.55 0.34 1.52 0.01 414.8 616.4 5515 21.110/7/05 11/29/05 Flock 1 O 1586 31.1 26.2 70.5 0.1 0.57 0.48 1.30 0.00 206.1 132.7 469.6 7.3

11/30/05 12/14/05 E 199 14.2 4.4 21.6 8.0 - - - - - - - -12/15/05 2/3/06 Flock 2 O 1673 32.8 25.3 70.5 4.0 0.61 0.47 1.32 0.07 394.1 433.8 2712 83.9

2/4/06 2/19/06 E 192 12.0 5.9 20.3 0.0 - - - - - - - -2/20/06 4/10/06 Flock 3 O 1372 31.2 21.1 63.6 5.7 0.57 0.39 1.18 0.10 520.0 764.6 4117 148.84/11/06 5/21/06 E 325 8.3 14.6 77.1 0.0 - - - - - - - -5/22/06 7/11/06 Flock 4 O 1747 36.4 26.8 78.2 5.9 0.69 0.51 1.49 0.11 386.2 242.1 1441 211.67/12/06 7/27/06 E 330 22.0 21.1 76.2 0.0 - - - - - - - -7/28/06 9/19/06 Flock 5 O 1978 37.3 16.6 64.0 11.5 0.71 0.32 1.21 0.22 499.7 477.9 2380 150.49/20/06 10/4/06 E 313 22.3 16.3 43.2 0.0 - - - - - - - -10/5/06 11/27/06 Flock 6 O 1851 34.9 12.9 55.6 8.7 0.63 0.23 1.00 0.16 482.1 621.1 3639 119.3

Tyson 3-3 between flocks E 1359 13.9 15.0 77.1 0.0 - - - - - - - -

Tyso

n3-3

Tyson 3-3 all 6 flocks O 10207 34.0 21.9 78.2 0.1 0.63 0.41 1.49 0.00 413.5 495.8 4117 7.3All between flocks (two houses) E 3427 19.3 18.2 98.6 0.0 - - - - - - - -All 12 flocks (two houses) O 18542 30.8 20.0 78.2 0.1 0.59 0.38 1.52 0.00 414.2 584.6 5515 7.3

Tyson Broiler Ammonia Emission Monitoring ProjectFinal Report-Page 26

[a] House condition O: Occupied; E: Empty [b] AU: 500 kg animal unit [c] This flock had unexpected high mortality due to the improper vaccine procedure at the hatchery

Table 3. Summary of ammonia emission rates for the two broiler houses monitored.

Page 31: Tyson Broiler Ammonia Emission Monitoring Project: Final

Emission rate per animal unit

Figures 20 and 21 present ammonia ER in terms of 500 kg animal unit (g/AU-d) for all 12 flocks from the two houses. The ERs per AU versus bird age show the different trends for the flocks with new litter and built-up litter. The ERs per AU of three flocks with new litter (Tyson 1-5 flocks 1 and 5, and Tyson 3-3 flock 1) increased from very lower levels and the peak occurred after 28-35 d bird age. The ERs per AU of the flocks with built-up litter started high but relatively trended to be stable with bird growth. Specifically, at the beginning of each flock with built-up litter, ER per AU varied from 1.4 to 5.5 kg/AU-d (Table 3). There was no significant difference between Tyson 1-5 and Tyson 3-3 in ER per AU (P=0.97). The daily ERs per AU were 413.5 ± 495.8 and 414.8 ± 661.4 g/AU-d for Tyson 1-5 and Tyson 3-3, respectively. The overall ER per AU was 414.2 ± 584.6 g/AU-d.

Tyson1-5(12/09/2005-1/28/2006)_Flock1

0

1000

2000

3000

4000

5000

6000

1 5 9 13 17 21 25 29 33 37 41 45 49

Bird age, day

NH 3

ER

, g/A

U-d

-30

-10

10

30

50

70

90O

utsi

de

Tem

pera

ture

, o FNH3, g Outside Temp, oF

Tyson1-5 (2/14/2006-4/04/2006)_Flock2

0

1000

2000

3000

4000

5000

6000

1 5 9 13 17 21 25 29 33 37 41 45 49

Bird age, day

NH3

ER

, g/A

U-d

-30

-10

10

30

50

70

90

Out

side

Te

mpe

ratu

re, o F

NH3, g Outside Temp, oF

Tyson1-5 (4/21/2006-6/09/2006)_Flock3

0

1000

2000

3000

4000

5000

6000

1 5 9 13 17 21 25 29 33 37 41 45 49

Bird age, day

NH 3

ER

, g/A

U-d

-30

-10

10

30

50

70

90

Out

side

Te

mpe

ratu

re, o F

NH3, g Outside Temp, oF

Tyson1-5 (6/22/2006-8/10/2006)_Flock4

0

1000

2000

3000

4000

5000

6000

1 5 9 13 17 21 25 29 33 37 41 45 49

Bird age, day

NH 3

ER

, lg/

AU

-d

-30

-10

10

30

50

70

90

Out

side

Te

mpe

ratu

re,

o F

NH3, g Outside Temp, oF

Tyson1-5 (9/05/2006-10/25/2006)_Flock5

0

1000

2000

3000

4000

5000

6000

1 5 9 13 17 21 25 29 33 37 41 45 49

Bird age, day

NH 3

ER

, g/A

U-d

-30

-10

10

30

50

70

90

Out

side

Te

mpe

ratu

re,

o F

NH3, g Outside Temp, oF

Tyson1-5 (11/17/2006-1/09/2007)_Flock6

0

1000

2000

3000

4000

5000

6000

1 5 9 13 17 21 25 29 33 37 41 45 49

Bird age, day

NH 3

ER

, g/A

U-d

-30

-10

10

30

50

70

90

Out

side

Te

mpe

ratu

re,

o F

NH3, g Outside Temp, oF

4-d missing

Figure 20. Tyson 1-5 NH3 ER per AU (500 kg) mean outside temperature vs. bird age

Tyson Broiler Ammonia Emission Monitoring ProjectFinal Report-Page 27

Page 32: Tyson Broiler Ammonia Emission Monitoring Project: Final

Tyson 3-3 (10/07/2005-11/28/2005)_Flock1

0

1000

2000

3000

4000

5000

6000

1 5 9 13 17 21 25 29 33 37 41 45 49 53

Bird age, day

NH3

ER

, g/A

U-d

-30

-10

10

30

50

70

90

Out

side

Te

mpe

ratu

re, o F

NH3, g Outside Temp, oF

3-d missing

Tyson3-3 (12/15/2005-2/03/2006)_Flock2

0

1000

2000

3000

4000

5000

6000

1 5 9 13 17 21 25 29 33 37 41 45 49

Bird age, day

NH3

ER

, g/A

U-d

-30

-10

10

30

50

70

90

Out

side

Te

mpe

ratu

re,

o F

NH3, g Outside Temp, oF

Tyson3-3 (2/20/2006-4/10/2006)_Flock3

0

1000

2000

3000

4000

5000

6000

1 5 9 13 17 21 25 29 33 37 41 45 49

Bird age, day

NH 3

ER

, g/A

U-d

-30

-10

10

30

50

70

90

Out

side

Te

mpe

ratu

re,

o F

NH3, g Outside Temp, oF

Tyson3-3 (5/22/2006-7/11/2006)_Flock4

0

1000

2000

3000

4000

5000

6000

1 5 9 13 17 21 25 29 33 37 41 45 49

Bird age, day

NH3

ER

, g/A

U-d

-30

-10

10

30

50

70

90

Out

side

Te

mpe

ratu

re, o F

NH3, g Outside Temp, oF

3-d missing

6-d missing

Tyson3-3 (7/28/2006-9/19/2006)_Flock5

0

1000

2000

3000

4000

5000

6000

1 5 9 13 17 21 25 29 33 37 41 45 49

Bird age, day

NH3

ER

, g/A

U-d

-30

-10

10

30

50

70

90

Out

side

Te

mpe

ratu

re, o F

NH3, g Outside Temp, oF

Tyson3-3 (10/05/2006-11/27/2006)_Flock6

0

1000

2000

3000

4000

5000

6000

1 5 9 13 17 21 25 29 33 37 41 45 49 53

Bird age, day

NH3

ER

, g/A

U-d

-30

-10

10

30

50

70

90

Out

side

Te

mpe

ratu

re,

o F

NH3, g Outside Temp, oF

one day missing

one-d missing

Figure 21. Tyson 3-3 NH3 ER per AU (500 kg) mean outside temperature vs. bird age

Emission rate during downtime between flocks

Ammonia emissions from the two houses were continuously monitored when the houses were empty between flocks or during downtime. Ventilation rate (VR) of the houses had a significant impact on the ER when the VR was lower than 80,000 cfm (Figure 22). However, it was also related to the litter management practice, e.g. litter decaking. The average ER for Tyson 1-5 and Tyson 3-3 downtime between flock periods was 26.2 ± 19.5 and 13.9 ± 15.0 lb/d-house, respectively. The average ER for the two houses during downtime was 19.3 ± 18.2 lb/d-house. These values are approximately two-thirds of the mean ER when birds were present in the houses.

Tyson Broiler Ammonia Emission Monitoring ProjectFinal Report-Page 28

Page 33: Tyson Broiler Ammonia Emission Monitoring Project: Final

Y = 0.0006X r2 = 0.5448

( VR< 80000 CFM )

Y = -5E-05X + 48 r2 = -0.0388

0

20

40

60

80

100

120

0 50000 100000 150000 200000 Daily Average VR, CFM/house

Am

mon

ia E

R, l

b/d-

hous

e ( VR ≥ 80000 CFM )

Figure 22. Ammonia emission rate(ER) vs. ventilation rate (VR) during downtime.

Ammonia Emission Rate Estimation/Prediction

Ammonia emission from the flocks with new litter and bird age less than 7 days (d) was significantly lower than later periods in the flock production cycle. Therefore, the ERs of the first 6 d with new litter would not fit the relationship of ER vs. bird age, body weight, VR, air temperature and relative humidity (RH). Excluding the first 6 days of ERs for the new litter flocks, the relationship of ER, bird age, body weight, VR, air temperature and RH was investigated.

Ammonia ER was highly correlated to the bird age, body weight and VR (Figure 23), but was weakly correlated with inside RH and not correlated with outside temperature and RH and inside temperature. Moreover, there exists a very strong positive relationship among bird age, body weight and VR. Among the three variables, bird age is predominant. Because of the large mortality in flock 6 at Tyson 1-5, this flock was not used to predict the ER. The NH3 ER per house or per bird from all data except for the flock 6 ERs at Tyson 1-5, as shown in Figures 24 and 25, may be estimated using the following predictive regression equations:

Tyson Broiler Ammonia Emission Monitoring ProjectFinal Report-Page 29

Page 34: Tyson Broiler Ammonia Emission Monitoring Project: Final

NH3 ER, lb/d-house = a + b X + c X2 + d X3 [2]

where

X= bird age, d, if built-up litter is used;

and X = ( bird age – 6) if new litter and bird age is ≥ 7 d;

NH3 ER = 0.55 lb/d-house if bird age < 7 d.

r=0.7754 r=0.7696 r=0.6206 r=0.1938 r=0.0321 r=-0.1517 r=0.5388

Bird age Body weight VR Outside T Outside RH Inside T Inside RH

NH

3, E

R

Figure 23. Multivariate matrix of ammonia ER vs. bird age, body weight, ventilation rate, air

temperature and relative humidity.

Table 4 provides the prediction parameter estimates for the two houses, individually, and overall 11 flocks. The correlation coefficients (r2) of prediction models vary from 0.75 to 0.83 and show the strongest relationship between ER and bird age.

Table 4. Coefficient Estimates of ammonia ER prediction models for the houses, Tyson 1-5 and Tyson 3-3 (ER is not included when bird age is < 7-d with new litter).

House a (± SE) b (± SE) c (± SE) d (± SE) r2

1-5 6.91

(± 1.11)

0.0773

(± 0.0045)

-0.0013

(± 0.0001) 0.75

3-3 15.4

(± 2.25)

-2.18

(± 0.363)

0.180

(± 0.016)

-2.46E-03

(± 1.94E-04) 0.83

Overall 10.7

(± 1.74)

-0.99

(± 0.285)

0.123

(± 0.013)

-1.76E-03

(± 1.59E-04) 0.77

For the flocks on new litter, there was no clear bird age effect of bird age, VR, air temperature or RH on ER. Therefore, the first 6-d ERs could be estimated by using the actual average ER (standard deviation), 0.55 lb/d-house (± 0.42) for the first 6-d ERs from three flocks on new litter.

Tyson Broiler Ammonia Emission Monitoring ProjectFinal Report-Page 30

Page 35: Tyson Broiler Ammonia Emission Monitoring Project: Final

0102030405060708090

100

Am

mon

ia E

R, l

b/d-

hous

e

0 10 20 30 40 50Bird age

Y = (6.91 ± 1.11)+ (0.0773 ± 0.0045) X^2 - (0.0013 ± 0.0001)X^3

Tyson 1-5

0102030405060708090

100

Am

mon

ia E

R, l

b/d-

hous

e

0 10 20 30 40 50Bird age

Y = (15.4 ± 2.25)- (2.18 ± 0.363)X + (0.180 ± 0.016) X^2 - (2.46E-03 ± 1.94E-04)X^3

Tyson 3-3

Figure 24. Relationship between ammonia ER per house vs. bird age for Tyson 1-5 and Tyson 3-3. The solid line is the regression line; dash lines are 95% prediction limit. In

the prediction equation, the coefficient values are mean ± standard error.

Tyson Broiler Ammonia Emission Monitoring ProjectFinal Report-Page 31

Page 36: Tyson Broiler Ammonia Emission Monitoring Project: Final

0102030405060708090

100

Am

mon

ia E

R, l

b/d-

hous

e

0 10 20 30 40 50Bird age

Y = (10.7±1.74)- (0.99±0.29)X + (0.123±0.013) X^2 - (0.0018±0.00016)X^3

Overall

Figure 25. Relationship between ammonia ER per house vs. bird age for all 12 flocks.

The solid line is the regression line; dash lines are 95% prediction limit. In the prediction equation, the coefficient values are Mean ± SE.

Annual Ammonia Emission The annual ammonia emission from each house is the accumulation of daily ERs over 365 days. However, some daily emissions were missing due to various reasons (for example, power outage from adverse weather and instrument malfunctions). There were a total of 10 missing days for Tyson 1-5 and 19 missing days for Tyson 3-3 over the one year monitoring period. The monitored annual emissions were 4.8 and 4.9 US tons per year from Tyson 1-5 and Tyson 3-3, respectively. Based on the regression of the ER on bird age from Equation [2], the missing daily ammonia emissions could be predicted for each house. After the missing emissions were filled with predicted values, the annual emissions were 5.0 and 5.2 US tons for Tyson 1-5 and Tyson 3-3, respectively. On a per 1000 birds marketed basis the average ammonia emissions over a six-flock period were 73.3 and 82.5 lb per 1000 birds marketed from Tyson 1-5 and Tyson 3-3, respectively. Combining both houses, the average annual ammonia emission was 5.1 US tons per year per house or 77.9 lb per 1000 birds marketed. It is worth noting that the annual mean emission of 77.9 lb per 1,000 birds marketed (including downtime emissions) obtained from this study is equivalent to 35.4 g/bird-marketed and is significantly lower than the emission factor of 100 g/bird-year (100 g/bird-marketed) for broilers used by the U.S. EPA.

Comparison of ER with Literature Data

Comparison of the reported ammonia emission rate (ER, g/bird-d) for broiler production houses (occupied with birds) in the United States is given in Table 5.

Tyson Broiler Ammonia Emission Monitoring ProjectFinal Report-Page 32

Page 37: Tyson Broiler Ammonia Emission Monitoring Project: Final

Table 5. Comparison of ammonia emission rates (ER, g/bird-d) of the commercial broiler houses among various U.S. studies.

Reference Growth Period, d

Stocking Density, birds/m2

Stocking Density, birds/ft2

Flocks Litter Mean ER, g/bird-d Location

This study 52 12.7 1.18 3 New 0.49

This study 52 12.2 1.13 9 Built-up 0.62 Kentucky, U.S.A

42 14.7 1.37 10 New 0.47

42 14.7 1.37 12 Built-up 0.65 49 13.4 1.24 24 Built-up 0.76

Wheeler et al. (2006)

63 10.8 1.00 20 Built-up 0.98

Kentucky and Pennsylvania,

U.S.A

Burns et al. (2003) 42 16.1 1.50 9 Built-up 0.92 Tennessee,

U.S.A Lacey et al.

(2003) 49 13.5 1.25 12 Built-up 0.63 Texas, U.S.A

Seifert et al. (2004) 42 20 1.86 1 Built-up 1.18 Delaware, U.S.A

Conclusions

Ammonia emissions from two representative broiler houses in western Kentucky were continuously measured for a full year, involving a total of 12 grow-out flocks (6 flocks per house). The following conclusions were drawn.

• There were both diurnal and seasonal variations in ammonia emission from the broiler houses.

• During grow-out period, ammonia emission rate (mean ± S.D.) was 27.2 ± 20.6 lb/d-house for flocks grown on new litter but 32.0 ± 19.6 lb/d-house for flocks grown on built-up litter. The large variation, as expressed by the standard deviation (S.D.), is attributed to the large range of bird age (1 to 52 d).

• The overall mean ammonia emission rate for the 12 flocks was 30.8± 20.0 lb/d-house. The maximum daily ammonia emission during the grow-out period was less than 80 lb/d-house (67.4 lb/d-house for T1-5 and 78.2 lb/d-house for T3-3).

• Ammonia emission rates during downtime (empty house between flocks) (mean ± S.D.) was 19.3 ± 18.2 lb/d-house. The downtime emission rate tends to be positively related to ventilation rate of the house and is significantly influenced by litter handling.

• Annual ammonia emission for the two broiler houses (including downtime emissions) averaged 5.1 US tons per house or 77.9 lb per 1000 birds marketed or 35.4 g per bird marketed when the bird was marketed at 52 days of age with a stocking density of 1.1 bird/ ft2. The ammonia emission factor for broilers revealed from this study, 35.4 g/bird-marketed, is significantly lower than that of 100 g/bird-year used by EPA.

Tyson Broiler Ammonia Emission Monitoring ProjectFinal Report-Page 33

Page 38: Tyson Broiler Ammonia Emission Monitoring Project: Final

• Regression equations have been developed that relate ammonia emission rate to broiler age. The first 6-d ER for flocks grown on new litter is relatively independent of the bird age at 0.55 ± 0.42 lb/d-house.

Tyson Broiler Ammonia Emission Monitoring ProjectFinal Report-Page 34

Page 39: Tyson Broiler Ammonia Emission Monitoring Project: Final

Acknowledgements Financial support of the study was provided by Tyson Foods, Inc. The authors wish to sincerely thank the growers of the commercial broiler operation for their cooperation throughout the study.

References Burns, R. T., K. A. Armstrong, F. R. Walker, C. J. Richards, and D.R. Raman. 2003. Ammonia emissions

from a broiler production facility in the United States. In Proc. International Symposium on

Gaseous and Odor Emissions from Animal Production Facilities, 88-95. Horsens, Denmark:

CIGR.

Casey, K.D. 2005. The determination of ammonia emissions from mechanically ventilated poultry houses,

an examination of the issues involved. Ph.D. dissertation. University of Kentucky, Biosystems and

Agricultural Engineering Department.

Casey, K.D., R.S. Gates, E.F. Wheeler, H. Xin and Y. Liang. 2007. Quantifying uncertainty of ammonia

emissions from mechanically ventilated broiler houses. Transactions of the ASABE. In

preparation.

Gates, R. S., K. D. Casey, H. Xin, E. F. Wheeler, and J. D. Simmons. 2004. Fan assessment numeration system (FANS) design and calibration specifications. Transactions of the ASAE 47(5): 1709-1715.

Doeblin, E.O. 1990. Measurement Systems Application and Design. 4th ed. ISGN 0-07-107338-9.

McGraw-Hill Publishing Co: New York. 960 pp.

Copeland, C. 2005. Air Quality Issues and Animal Agriculture: EPA’s Air Compliance Agreement. CRS

Report for Congress, Order Code RL32947.

Demmers, T. G. M., L. R. Burgess, J. L. Short, V. R. Phillips, J. A. Clark, and C. M. Wathes. 1999.

Ammonia emissions from two mechanically ventilated U.K. livestock buildings. Atmospheric

Environ. 33(2): 217-227.

Fenyvesi, L., ,L. Matyas, I. Pazsiczki, L. Kovacs, H. Sonnenberg, G. Hornig, and U. Stollberg. 2001.

Possibilities for reducing gas emission of animal husbandry. Proceedings of the 2nd Agricultural

Engineering Conference and East European Countries, 20-23.

Groot Koerkamp, P. W. G., J. H. M. Metz, G. H. Uenk, V. R. Phillips, M. R. Holden, R. W. Sneath, J. L.

Short, R. P. White, J. Hartung, J. Seedorf, M. Schroeder, K. H. Linkert, S. Pedersen, H. Takai, J.

O. Johnsen, and C. M. Wathes. 1998. Concentrations and emissions of ammonia in livestock

buildings in northern Europe. J. Agric. Eng Res. 70(1): 79-95.

Guarino, M., C. Fabbri, P.Navarotto, L. Valli, G. Moscatelli, M. Rossetti, and V. Mazzotta. 2003. Ammonia,

methane and nitrous oxide emissions and particulate matter concentrations in two different

building for fattening pig. In Proc. International Symposium on Gaseous and Odor Emissions from

Animal Production Facilities, 140-149. Horsens, Denmark: CIGR.

Tyson Broiler Ammonia Emission Monitoring ProjectFinal Report-Page 35

Page 40: Tyson Broiler Ammonia Emission Monitoring Project: Final

Lacey, R. E., J. S. Redwine, and C. B. Parnell, Jr. 2003. Particulate matter and ammonia emission factors

for tunnel-ventilated broiler production houses in the southern U.S. Trans. ASAE 46(4): 1203-

1214.

Liang, Y., H. Xin, E. F. Wheeler, R. S. Gates, J. S. Zajaczkowski, P. Topper, H. Li and K. D. Casey. 2005.

Ammonia emissions from U.S. laying hen houses in Iowa and Pennsylvania. Trans. ASAE 48(5):

1927-1941.

Moody, L., H. Li, R. Burns, H. Xin and R. Gates. 2006. Quality Assurance Project Plan (QAPP) for

monitoring gaseous and particulate matter air emissions from southeastern broiler houses.

Proceedings of the Symposium on Air Quality Measurement Methods and Technology, 9-11 May,

DurhamNC. AWMA.

Müller, H.-J., R. Brunsch, G. Hörnig, and A. Jelínek. 2003. Odour and ammonia emissions from poultry

houses with different keeping and ventilation systems. In Proc. International Symposium on

Gaseous and Odor Emissions from Animal Production Facilities, 172-179. Horsens, Denmark:

CIGR.

National Research Council. 2003. Air Emissions from Animal Feeding Operations: Current Knowledge,

Future Needs. National Academy Press, Washington, DC. ISBN: 0-309-08705-8; www.national-

academies.org.

Nicks, B., M. Laitat., M. Vandenheede, A. Desiron, C. Verhaeghe, B. Canart. 2003. Emissions of

Ammonia, Nitrous Oxide, Methane, Carbon Dioxide and Water Vapor In the Raising of Weaned

Pigs on Straw-based and Sawdust-based Deep Litters. Animal Research. 52:299–308

Seifert, R. L., J. R. Scudlark, A. G. Potter, K. A. Simonsen and K. B. Savidge. 2004. Characterization of

atmospheric ammonia emission from a commercial chicken house on the Delmarva Peninsula.

Environ. Sci. Tech. 38(10): 2769:2778.

Southeastern Broiler Gaseous and Particulate Matter Emission Monitoring Quality Assurance Project

Plan. 2006. Prepared by Iowa State University and the University of Kentucky.

U.S. Environmental Protection Agency, National Emission Inventory – Ammonia Emissions from Animal

Husbandry Operations. See

http://www.epa.gov/ttnchie1/ap42/ch09/related/nh3inventorydraft_jan2004.pdf (accessed March,

2005).

Wheeler, E. F., K. D. Casey, R. S. Gates, H. Xin, J. L. Zajaczkowski, P. A. Topper, Y. Liang, A. J.

Pescatore. 2006. Ammonia emissions from twelve U.S. broiler chicken houses. Trans. ASABE

49(5): 1495−1512

Recent Literature Burns, R.T., H. Xin, H. Li, S. Hoff, L. Moody, R. Gates, D. Overhults and J. Earnest. 2006. Monitoring

system design for the southeastern broiler gaseous and particulate matter air emissions

monitoring project. Proceedings of the Symposium on Air Quality Measurement Methods and

Technology, 9-11 May, DurhamNC. AWMA.

Tyson Broiler Ammonia Emission Monitoring ProjectFinal Report-Page 36

Page 41: Tyson Broiler Ammonia Emission Monitoring Project: Final

Burns, R., H. Xin, R. Gates, H. Li, S. Hoff, L. Moody, D. Overhults and J. Earnest. 2006. Monitoring

system design for the southeastern broiler gaseous and particulate matter air emissions

monitoring project. Presented at: Workshop on Agricultural Air Quality: State of the Science,

Bolger Conference Center, Potomac MD. 5-8 June. ESA.

Casey, K.D., R.S. Gates, E.F. Wheeler and H. Xin. 2006. Comparison of measured estimates of annual

ammonia emissions from poultry production facilities with mass balance modeling approaches.

Presented at: Workshop on Agricultural Air Quality: State of the Science, Bolger Conference

Center, Potomac MD. 5-8 June. ESA.

Casey, K.D., R.S. Gates, A. Singh, A.J. Pescatore, E.F. Wheeler, H. Xin, Y. Liang. 2006. Managing Litter

to Reduce Ammonia Emissions from Broiler Chicken Houses in the U.S.A. In Proceedings of

Poultry Information Exchange 2006, Surfers Paradise, Gold Coast, Australia, April 2-4.: PIX

Association Inc. Casey, K.D., J.R. Bicudo, D.R. Schmidt, A. Singh, S.W. Gay, R.S. Gates, L.D. Jacobson and S.J. Hoff.

2006. Air quality and emissions from livestock and poultry production/waste management

systems. Pp 1-40 in: Animal Agriculture and the Environment: National Center for Manure and

Animal Waste Management White Papers. J.M. Rice, D.F. Caldwell, F.J. Humenik, eds. ASABE:

St. Joseph MI.

Gates, R.S., K.D. Casey, E.F. Wheeler and H. Xin. 2006. Estimating annual ammonia emissions from

U.S. broiler facilities. Presented at: Workshop on Agricultural Air Quality: State of the Science,

Bolger Conference Center, Potomac MD. 5-8 June. ESA.

Gates, R.S., K.D. Casey, E.F. Wheeler, H. Xin and A.J. Pescatore. 2007. U.S. broiler ammonia emissions

inventory model. Atmospheric Environment. Accepted for publication.

Moody, L., H. Li, R. Burns, H. Xin and R. Gates. 2006. Quality Assurance Project Plan (QAPP)

implementation for the southeastern broiler gaseous and particulate matter air emissions

monitoring project. Presented at: Workshop on Agricultural Air Quality: State of the Science,

Bolger Conference Center, Potomac MD. 5-8 June. ESA.

Topper, P.A., E.F. Wheeler, J.S. Zajaczkowski, R.S. Gates, H. Xin, Y. Liang and K.D. Casey. 2006.

Ammonia emissions from two empty broiler houses with built-up litter. Transactions of the

ASABE: In press.

Tyson Broiler Ammonia Emission Monitoring ProjectFinal Report-Page 37