typical installation details - carnes louvers · c-18 accessories typical installation details -...

1
C-18 ACCESSORIES Typical Installation Details - Carnes Louvers Masonry Wall Metal Panel Wall Wood Installation Flange Mount Angle Subframe CMU Louver Extended Sill Extended Sill Louver Drip Cap Insulation Corrugated Metal Louver Siding Sheathing 2 x 4 Wood Blocking Louver Louver Frame Angle Accessories at additional cost. Suggested are (2) 7/32” diameter holes and (2) #10 x 5/8” s.s. / s.m. screws for angle attachement to louver. Not by Carnes. To prevent corrosion, apply heavy coating of bituminous paint on any surface in contact with concrete, masonry, or dissimilar metals. Holes for attachment to wall conditions drilled in field by customer. Anchors for your specific installation not supplied by Carnes. Louver Louver Louver Frame CMU

Upload: phamxuyen

Post on 14-Jul-2018

214 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Typical Installation Details - Carnes Louvers · C-18 ACCESSORIES Typical Installation Details - Carnes Louvers Masonry Wall Metal Panel Wall Wood Installation Flange Mount Angle

C-18

AC

CESSO

RIES

Typical Installation Details - Carnes Louvers

MasonryWall

Metal PanelWall

WoodInstallation

FlangeMount

AngleSubframe

CMU

Louver

ExtendedSill

ExtendedSill

Louver

Drip Cap

Insulation

CorrugatedMetal

Louver

Siding

Sheathing

2 x 4Wood

Blocking

Louver

LouverFrame

Angle

Accessories at additional cost.

Suggested are (2) 7/32” diameter holes and (2)

#10 x 5/8” s.s. / s.m. screwsfor angle attachement to louver. Not by Carnes.

To prevent corrosion, apply heavycoating of bituminous paint on anysurface in contact with concrete,masonry, or dissimilar metals.

Holes for attachment towall conditions drilled in

field by customer. Anchorsfor your specific installation

not supplied by Carnes.

Louver

Louver

LouverFrame

CMU