types 2074, 2174 & 2274 digital industrial gauge 2074, 2174 & 2274 digital industrial gauge...

3
Types 2074, 2174 & 2274 Digital Industrial Gauge BULLETIN DIG-1 PRODUCT SPECIFICATIONS Type: 2074 (battery), 2174 (loop), 2274 (line) Accuracy: .25% Full Scale, terminal point Case Size: 3˝, 4 1 2˝ Case Material: 3˝ SS, 4 1 2˝ fiberglass reinforced thermoplastic or black epoxy coated aluminum Case Encl. Rating: Weatherproof, IP65 Electrical Connection for Loop or Line Power: 4 1 2˝ case screw down terminals 3˝ case jacketed cable extended 3 feet For different cable length use variation “JZ” Wetted Materials: 17-4 SS (sensor), 316SS (socket) Socket Sizes: 1 4 NPT, 1 2 NPT, typical, see coding for com- plete list. Consult factory for additional fittings. Socket Location: Lower, 3, 9 and 12 o’clock Ranges: Vac. thru 20,000 psi (see engineering units below for other units) Overpressure Limits (F.S.): 15- 3000- 7500- 2000 5000 20,000 Proof 200% 150% 120% Burst 800% 300% 150% Operating Temp.: 14/140°F (–10/60°C) Temp. Error (Zero & Span): .04%/°F (<.02%°F Typical) Storage Temp.: –4/158° (–20°/70°F) DISPLAY Type: LCD Display Digits: Five (5) Character Height: 3˝ case: .60˝, 4 1 2˝ case: .88˝ Backlite: Optional. On model 2174 only, battery backup must also be selected. (Backlight is powered by bat- teries.) Bar Graph: Yes Battery Life: 3˝ >400 hrs., 4 1 2˝ >2000 hrs. Battery Backup: Optional. Agency Approvals: Optional Intrinsically Safe Approvals FM (Class I Div. I, Groups A-G) CSA (Class I Div. I, Groups A-D) (Class II Div. I, Groups E-G) 15,000 psi Max Full Scale Range KEYPAD FUNCTIONS On/Off: Manually turns unit on and off (auto off options in menu) Zero/Clear: Zeros display or clears min. and max. values when displayed Min/Max: (down) Arrow Key: Stores min and max values, arrow key allows for scrolling thru menu items Menu Key: Provides access to menu options Backlite: (up) Arrow Key (Backlite optional): Manually turns backlite on and off (auto off options in menu), arrow key allows for five menu options. (up) arrow key allows for scrolling thru menu options Enter: Selects items in the menu MENU MODE Engineering Units: Up to 10 units of measurement are available; psi, In. H2O (with three temp. options: 20°C, 60°F, 4°C*), Ft. H 2 O, mPa, mBar, kPa, kg/cm 2 , Bar, inHg and mmHg. Units available are based on full scale range of gauge. Configuration Mode (Config): Allows for changes to default settings of gauge including zero disable feaure Bar Graph (Graph): Allows for adjustment of bargraph and 4-20 (optional feature) Auto Off (Off): Allows for changes to auto off of gauge, five options: Never, 2 min., 5 min., 15 min., 30 min. Update Rate (Update): Four options: 100 ms, 200 ms, 500 ms, 1 sec Dampening (Damp): Six options: None, average, 2, 4, 6, 8 times per 100ms Backlite: Five options: Never, 10 sec., 30 sec., 1 min., 5 min. Field Recalibration: Allows for recalibration of zero, midscale and span (password protected) OPTIONS 4-20mA Display: 12-36 Vdc, mA with unlimited turndown (within gauge range) Line Powered: 12-36 Vdc, 2VA max. Switching*: (1) or (2) SPDT switches,(max. contact 30Vdc, 1 amp, 125Vac .5 Amp), Switches adjustable to 100% of range Ashcroft Inc., 250 East Main Street, Stratford, CT 06614 USA Tel: 203-378-8281 • Fax: 203-385-0408 email: [email protected] • www.ashcroft .com All specifications are subject to change without notice. All sales subject to standard terms and conditions. © Ashcroft Inc. 2017 Rev. A 07/17 At last, a multi-functional gauge from the experts in pressure measurement. When any combination of local indication, a 4-20mA signal and switching are required to meet your needs, the Ashcroft ® digital industrial gauge provides the solution. FEATURES • A Multi-Functional Digital Gauge with Optional: - 4-20mA Output - (1) or (2) SPDT Switches 1 4% Full Scale Terminal Point Accuracy (.13% BFSL) • IP 65 Weatherproof Case • Three Case Options: Stainless Steel, Fiberglass Reinforced Thermoplastic or Aluminum • Extra Large Display • Intrinsically Safe, Class I, Div. 1 • Easy-to-Use Menu Options: (all password protected) - Five Backlite Display Options - Twelve Engineering Units - Menu Configure Feature - Update Rate - Dampen Rate - Auto-Off LOOK FOR THESE AGENCY MARKS ON OUR PRODUCTS

Upload: buithuy

Post on 27-Mar-2018

226 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Types 2074, 2174 & 2274 Digital Industrial Gauge 2074, 2174 & 2274 Digital Industrial Gauge THE MULTI-FUNCTIONAL OPTIONS Description Code Case Size Case Options Aluminum Case (black

Types 2074, 2174 & 2274 Digital Industrial Gauge

BULLETIN DIG-1

PRODUCT SPECIFICATIONSType: 2074 (battery), 2174 (loop), 2274 (line)Accuracy: .25% Full Scale, terminal point Case Size: 3˝, 41⁄2˝Case Material: 3˝ SS, 41⁄2˝ fiberglass reinforced

thermoplastic or black epoxy coated aluminumCase Encl. Rating: Weatherproof, IP65Electrical Connection for Loop or Line Power:

41⁄2 ̋case screw down terminals 3˝ case jacketed cable extended 3 feet For different cable length use variation “JZ”

Wetted Materials: 17-4 SS (sensor), 316SS (socket)Socket Sizes: 1⁄4 NPT, 1⁄2 NPT, typical, see coding for com-

plete list. Consult factory for additional fittings.Socket Location: Lower, 3, 9 and 12 o’clockRanges: Vac. thru 20,000 psi (see engineering units below

for other units) Overpressure Limits (F.S.): 15- 3000- 7500- 2000 5000 20,000Proof 200% 150% 120%Burst 800% 300% 150%Operating Temp.: 14/140°F (–10/60°C)Temp. Error (Zero & Span): .04%/°F (<.02%°F Typical)Storage Temp.: –4/158° (–20°/70°F)

DISPLAYType: LCDDisplay Digits: Five (5)Character Height: 3˝ case: .60˝, 41⁄2˝ case: .88˝ Backlite: Optional. On model 2174 only, battery backup

must also be selected. (Backlight is powered by bat-teries.)

Bar Graph: YesBattery Life: 3˝ >400 hrs., 41⁄2˝ >2000 hrs.Battery Backup: Optional.Agency Approvals:

Optional Intrinsically Safe Approvals FM (Class I Div. I, Groups A-G) CSA (Class I Div. I, Groups A-D) (Class II Div. I, Groups E-G) 15,000 psi Max Full Scale Range

KEYPAD FUNCTIONSOn/Off: Manually turns unit on and off (auto off options in

menu)Zero/Clear: Zeros display or clears min. and max. values

when displayedMin/Max: (down) Arrow Key: Stores min and max values,

arrow key allows for scrolling thru menu items Menu Key: Provides access to menu optionsBacklite: (up) Arrow Key (Backlite optional): Manually

turns backlite on and off (auto off options in menu), arrow key allows for five menu options. (up) arrow key allows for scrolling thru menu options

Enter: Selects items in the menuMENU MODEEngineering Units: Up to 10 units of measurement are

available; psi, In. H2O (with three temp. options: 20°C, 60°F, 4°C*), Ft. H2O, mPa, mBar, kPa, kg/cm2, Bar, inHg and mmHg. Units available are based on full scale range of gauge.

Configuration Mode (Config): Allows for changes to default settings of gauge including zero disable feaure

Bar Graph (Graph): Allows for adjustment of bargraph and 4-20 (optional feature)

Auto Off (Off): Allows for changes to auto off of gauge, five options: Never, 2 min., 5 min., 15 min., 30 min.

Update Rate (Update): Four options: 100 ms, 200 ms, 500 ms, 1 sec

Dampening (Damp): Six options: None, average, 2, 4, 6, 8 times per 100ms

Backlite: Five options: Never, 10 sec., 30 sec., 1 min., 5 min.

Field Recalibration: Allows for recalibration of zero, midscale and span (password protected)

OPTIONS4-20mA Display: 12-36 Vdc, mA with unlimited turndown

(within gauge range)Line Powered: 12-36 Vdc, 2VA max. Switching*: (1) or (2) SPDT switches,(max. contact

30Vdc, 1 amp, 125Vac .5 Amp), Switches adjustable to 100% of range

Ashcroft Inc., 250 East Main Street, Stratford, CT 06614 USATel: 203-378-8281 • Fax: 203-385-0408email: [email protected] • www.ashcroft .com

All specifications are subject to change without notice. All sales subject to standard terms and conditions. © Ashcroft Inc. 2017 Rev. A 07/17

At last, a multi-functional gauge from the experts in pressure measurement.When any combination of local indication, a 4-20mA signal and switching are required to meet your needs, the Ashcroft® digital industrial gauge provides the solution.

FEATURES• A Multi-Functional Digital Gauge with

Optional: - 4-20mA Output - (1) or (2) SPDT Switches

• 1⁄4% Full Scale Terminal Point Accuracy (.13% BFSL)

• IP 65 Weatherproof Case• Three Case Options:

Stainless Steel, Fiberglass Reinforced Thermoplastic or Aluminum

• Extra Large Display• Intrinsically Safe, Class I, Div. 1• Easy-to-Use Menu Options:

(all password protected) - Five Backlite Display Options - Twelve Engineering Units - Menu Configure Feature - Update Rate - Dampen Rate - Auto-Off

LOOK FOR THESE AGENCY MARKS ON OUR PRODUCTS

Page 2: Types 2074, 2174 & 2274 Digital Industrial Gauge 2074, 2174 & 2274 Digital Industrial Gauge THE MULTI-FUNCTIONAL OPTIONS Description Code Case Size Case Options Aluminum Case (black

Types 2074, 2174 & 2274 Digital Industrial Gauge

OPTIONS Description Code Case Size Case Options Aluminum Case (black epoxy coated) AY 41⁄2˝ only (Glass reinforced thermoplastic case standard) Electropolished Case EC 3˝ only (Brushed SS case standard) Switch Options (1) SPDT Switch (12-36Vdc) U1 3˝, 41⁄2˝ (2) SPDT Switch (12-36Vdc) U2 3˝, 41⁄2˝ Line Power with 4-20mA output AO 3˝, 41⁄2˝ (Line power (Type 2274) required for switching options.) (Terminal blocks standard with 41⁄2˝ case.) (Flying leads standard with 3˝) Wiring Options Jacketed cable 3 ft. EN 41⁄2˝ Jacketed cable custom length JZ 3˝, 41⁄2˝ Keypad Options Backlite BL 3˝, 41⁄2˝ Miscellaneous Options Battery Backup BK 3˝, 41⁄2˝ (Battery standard with Type 2074) (Available with Types 2174 & 2274) Weatherproof ABS Gauge Carrying Case S7 3˝ only Protective Rubber Boot (black) B1 3˝ only Protective Rubber Boot (orange) B2 3˝ only Protective Front Cover PP 3˝ only AccuSealSM (1⁄2 NPT lower only) SU 41⁄2˝ only Intrinsically Safe FM FM/CSA

THE MULTI-FUNCTIONAL SOLUTION SAVES MONEY, TIME AND SPACE…n Battery powered local indication standardn Optional 4-20mA output with turndown adjust-

able within range of gauge*n Optional line powered (12-36 Vdc) n Optional (1) or (2) SPDT switches with dead-

band adjustable to pressure range of gauge *Accuracy based on full scale range of gauge

The benefit, one digital pressure gauge replaces three instruments… mechanical pressure gauge, transducer and switch n Saves installation costsn Saves on instrument costsn Save on additional pipe cut-out(s)n Save space

INDUSTRY LEADING FEATURESRugged design n Three case styles: all welded stainless steel,

fiberglass reinforced thermoplastic or cast alu-minum case - Weatherproof, NEMA4, IP 65 case - SS and aluminum case offered with FM certification, Class 1, Div. 1

n Polyester window protects display from damage

n Strain relief to protect wiring while replacing batteries

Industry leading displayn Extra large display height of .88˝ (41⁄2˝ case)n Five digit displayn 10 units of measuren % of full scale range bar graph

Safetyn Meets ASME B40.7n Pressure range on keypad and bar graph

reduces accidental overpressure n Proof pressure = 2X gauge range

Breakthru AccuSealsm Gauge Isolator*

n Integral to gauge

n Virtually eliminates process dead-leg

n Eliminates need for standard diaphragm seal

n Eliminating seal reduces temperature error

Press to display minimum or maximum pressure gauge measured by

.88˝ high digital display (41⁄2˝ case)

Bar graph % of full scale range

Battery level indicator

Optional:

• 4-20mA output (adjustable within pressure range)

• Line power (12/36Vdc, 1 amp)

• (1) or (2) SPDT switch(es) (adjustable to 100% of pressure range)

Range on keypad, complies with ASME B40.7 to reduce the possibility of accidental overpressure

What you should know about digital gauge accuracy… Terminal Point versus Best Fit Straight Line Accuracy. Ashcroft Type 2070 Digital Gauge with Terminal Point AccuracyBENEFIT

• All points between zero and full-scale will be within stated accuracy

• Allows zeroing of gauge at start-up to eliminate any sensor offset

Competitive Digital Gauges with Best Fit Straight Line (BFSL) Accuracy

• Linearity error mini-mized by “best” fitting a straight line to a non-linear curve

• BFSL gauges may have a zero offset at calibration that must be maintained to ensure accuracy throughout range

PROBLEM• Re-zeroing gauge may invalidate published accuracy

specification

• Zero offset at start-up may be the result of either: - BFSL Calibration - Zero Drift

BFSL minimizes linearity errorby “best” fitting a straight lineto a non-linear curve

R A N G E

P R

E S

S U

R E

0%100%

100%

Terminal Point: end points (zeroand full scale) are connectedby a straight line

R A N G E

P R

E S

S U

R E

0%100%

100%

BULLETIN DIG-1

Ashcroft Inc., 250 East Main Street, Stratford, CT 06614 USATel: 203-378-8281 • Fax: 203-385-0408email: [email protected] • www.ashcroft .com

All specifications are subject to change without notice. All sales subject to standard terms and conditions. © Ashcroft Inc. 2017 Rev. A 07/17

Page 3: Types 2074, 2174 & 2274 Digital Industrial Gauge 2074, 2174 & 2274 Digital Industrial Gauge THE MULTI-FUNCTIONAL OPTIONS Description Code Case Size Case Options Aluminum Case (black

Types 2074, 2174 & 2274 Digital Industrial Gauge

ÿ 5.79

1.60

1.68

2.62

4.87

3.47

1/2 NPTCONDUIT

38ϒ

3.98

Dia. 5.38BOLT CIRCLE

3X Dia.

.62ACROSS FLATS

1/2 OR 1/4NPT

.22

Dia. 5.79

Dia. 5.37BOLT CIRCLE

37ϒ

3.9

Dia. 5.81

3X Dia. .24

.62ACROSS FLATS

1/2 OR 1/4NPT 1.5

2.6

1.4

3.3

Dia.5.19

DIMENSIONSType 2074 (battery), 2174 (loop), 2274 (line), 41⁄2˝ aluminum case

Type 2074 (battery), 2174 (loop), 2274 (line), 41⁄2˝ fiberglass reinforced thermoplastic case

Flanged Mounting Ring

Flanged Mounting Ring

CLAMPING RING (1278G ONLY)

WASHER

SPACER POST(3 REQ’D)

“B” (3 REQ’D)

PANEL

MOUNTINGRING

6˝ RING DIA.

5.65˝ PANELOPENING

5/16˝ MAX PANEL THICKNESS

CLAMPING RING (1278G ONLY)

WASHER

SPACER POST(3 REQ’D)

“B” (3 REQ’D)

PANEL

MOUNTINGRING

6˝ RING DIA.

5.65˝ PANELOPENING

5/16˝ MAX PANEL THICKNESS

100%0%

www.ashcroft.com

3.34

1.70

.61

4.34

Type 2074 (battery), 2174 (loop), 2274 (line), 3˝ stainless steel case

4.00

1.860

.17

(Flange welded to case)

in.Hg Comp. mmHg in.Hg in. ft. Bar/ psi (vacuum) (psi) (pressure) (pressure) H2O mBar H2O mPa kPa KSC

15 30 -15/0/15 800 30 400 1000 60 1 100 1

30 -15/0/30 1000 60 800 1500 160 1.6 160 1.6

60 -15/0/60 2000 100 1000 2000 200 2.5 250 2.5

100 -15/0/100 3000 160 2500 300 4 400 4

160 5000 200 4000 400 6 600 6

200 10,000 300 5000 600 10 1000 10

300 400 6000 1000 16 1600 16

600 600 10,000 25 2500 25

800 800 15,000 40 4000 40

1000 20,000 60 6000 60

1500 100 10,000 100

2000 140 16,000 160

3000 25,000 250

5000 40,000 400

8000 60,000 600

10,000 100,000 1000

15,000 140,000 1400

20,000

BULLETIN DIG-1

PRESSURE RANGES

45 4.5˝30 3˝

2074 Ashcroft Battery Power .25%2174 Ashcroft 4-20 Loop .25%2274 Ashcroft 24V Line Power .25%

S St. St. D Dry 45 ONLY

04 1/2 NPT15 G 1/2 B

09 9/16-18 UNF 2B Female

LF 7/16-20 w/O-ring Seat

02 1/4 NPT13 G 1/4 B

30 ONLY

BOTH

RX 9/16-18 LH w/Cone

KJ 1/4 BSPF

SF 1/4 VCR Swivel Female

SM 1/4 VCR Swivel Male

L LowerE 9 O’ClockD 3 O’ClockT Top

2072

System

45 S

Case Style

D

Connection Size Connection Location

04 L

Range Code

100# X6W

TypeSize Product Variations For all Gauge Sizes XBK Battery Backup, for none Bat power Gauge XBL Back light for display (6) XAO 4-20mA, Output for Line Power Gauges XU1 1 SPDT Switch (1), (2) XU2 2 SPDT Switches (1), (2) XFM Factory Manual Approval (4) XNH Metal tag wired to case XNN Paper tag bonded to case X6B Cleaned for gaseous oxygen service XC4 CD-4 error plot XMF Free from mercury certiificate XTS Throttle screw XJZ Special cable length

For 3.0˝ gauges only XHN Mini Hirschmann Connector XTU Throttle plug XFF Front flange for panel mounting XPP Protective front cover XB1 Black rubber protective boot XB2 Orange rubber protective boot

For 4.5˝ gauges only XEN Flying leads (standard on “Size 30” 3 ft.) XAY Aluminum case XSU Accu-Seal, sensor at end of socket, 2000 psi max. 1⁄2 NPT only

NOTES: (1) Line power (Type 2274) required for switch options.

(2) Screw down terminals standard with 41⁄2˝ case. 3 feet of jacketed cable standard with 3˝ case.

(4) FM not available with variation codes U1, U2, BL, Ao, NH, NN, MN, HN, AY. 41⁄2˝includes aluminum case.

(6) On 2174 loop powered gauge only with BL option. BK option also must be specfied in product code (XBKBL).

Ashcroft Inc., 250 East Main Street, Stratford, CT 06614 USATel: 203-378-8281 • Fax: 203-385-0408email: [email protected] • www.ashcroft .com

All specifications are subject to change without notice. All sales subject to standard terms and conditions. © Ashcroft Inc. 2017 Rev. A 07/17