tuffcam™ swing clamps - vektekwhat makes the cam follower ball seat so special in these units? the...
TRANSCRIPT
![Page 1: TuffCam™ Swing Clamps - VektekWhat makes the cam follower ball seat so special in these units? The three cams and cam balls guide the rotation of the plunger providing greater support](https://reader034.vdocuments.us/reader034/viewer/2022042420/5f36ff427a75be74143d5e7e/html5/thumbnails/1.jpg)
© Vektek, April 2019 800-992-0236 www.vektek.com
When do you recommend the use of TuffCam™ Swing Clamps over the standard product? Applications where speed is essential, massive arms are required, or position sensing is necessary, use the TuffCam™ design most effectively. When speed is essential, VersaCam™ Clamps (which last millions of cycles in ordinary applications) may not live up to life cycle expectations. If a VersaCam™Swing Clamp is damaged early in its life due to speed abuse, replacement with a TuffCam™ Swing Clamp may be a way to maintain speed requirements and lengthen device life. Where arm mass damages the swing mechanism of VersaCam Swing Clamps, the tri-cam design of TuffCam™ strengthens the ball and cam link. The beefier design, capacity and reinforced rotation mechanism of the TuffCam™ could be your best solution.
Can I run the TuffCam™ Swing Clamp at any speed I want? No, there are restrictions. TuffCam™ Swing Clamps are capable of approximately two times the speed of VersaCam Swing Clamps in prolonged use without damage. In the event that you need faster speeds or larger arms, please understand that the life of even TuffCam™ Swing Clamps is reduced. Consult the Clamp Time and Flow Rate chart on the next page to determine the maximum speed for your application.
What makes the cam follower ball seat so special in these units? The three cams and cam balls guide the rotation of the plunger providing greater support and directional stability. The patented cam follower design is unique in the industry and uses solid carbide balls and composite ball seats. The ball seat design assures that the ball rolls in the cam rather than jamming and scraping resulting in wear on both the cam track and ball.
The demands on my fixture have changed and I am considering your TuffCam™ Swing Clamps. Can I switch out TuffCam™ for your standard product? Yes, the TuffCam™ Swing Clamps have the same mounting envelope as their VersaCam swing clamp counterparts.
I want to use Work Supports with TuffCam™Swing Clamps. Will the Work Supports cycle fast enough to keep up with the part change outs? There will be some lag between the unclamp of Swing Clamps and the full release of pressure in any work support circuit. This is critical with fluid advance supports. The circuit must have time to evacuate under low pressure to allow the plungers to retract for reloading the fixture. If speed is the issue in support retraction coordinating with TuffCam™, an air advance support must be used with the air circuit released prior to hydraulic circuit release. When the hydraulic circuit is released, the support will begin to immediately retract pushing only the air from the line rather than the higher viscosity hydraulic fluid.
I’m using a high-volume pump and it is “blowing out” my Swing Clamps. Will TuffCam™ Swing Clamps take care ofthis problem? High-volume pumps often incorporate high-volume accumulators. An accumulator will yield excessive flow, approaching instantaneous infinite flow and is intended for dynamic loads. Hydraulic clamps are used to hold static loads. Excessive flow may continue to damage clamps, even TuffCam™ clamps. We recommend changing to a pump designed for clamping applications restrict flow to the table on the next page.
My applications requires clamps to hit my part in the exact place every time. Should I use your TuffCam™ Swing Clamps? TuffCam™ Swing Clamps will be more precise in their point of contact. Keep in mind that any draft angle or side forces will ultimately damage the cam tracks of any Swing Clamp and result in loss of precision. In the case of precision positioning, guide pins are recommended and may be implemented with a single-ended ordouble-ended arm.
What defines a TuffCam™ Swing Clamp? The single direction, tri-cam design of TuffCam™produces the strength and reliability to support faster speeds and larger arms. This design also delivers noticeably better accuracy and repeatability over other brands. The clocking feature, included on all styles, dramatically reduces the time it takes to change arms for maintenance, replacement or design setup.
How can I measure the clamp speed? The maximum speed of a Swing Clamp is applicable to both clamp and unclamp function, as the momentum on the cam track and cam follower apply to both movements. To approximate the speed of your application: * Look down the centerline of the swing clamp, perpendicular to the arm. * Actuate your clamping system while watching the arm “swing” into position. * The eye can track speed of movement at roughly 1/16 second. If while looking directly into the end of the Swing Clamp, you can observe the arm move through its swing, the positioning time should be somewhere around ½ second or longer. See flow rates and clamping time on the next page. * If, while looking directly into the end of the Swing Clamp, you cannot observe the arm move, or it is unclamped and the next thing you can see is the device is in the clamped position, the positioning time is something substantially less than 1/2 second. Your standard model clamp is at risk of premature failure. However, the TuffCam™ Swing Clamps can actuate at a faster speed. See flow rates and clamping time on the next page. * It is possible to approximate the clamp time by adding the total active volume of devices in the specific control branch of your system and dividing that volume (cubic inches) by your pump’s output volume (cubic inches per minute) and then multiply that number by 60 (60 seconds per minute). This will give you the theoretical calculated time to move a device through its stroke, but does not account for flow loss due to restrictions in the system.
*TuffCam™ is a trademark of Vektek LLC
TuffCam™ Swing Clamps
Frequently Asked Questions
C-1
![Page 2: TuffCam™ Swing Clamps - VektekWhat makes the cam follower ball seat so special in these units? The three cams and cam balls guide the rotation of the plunger providing greater support](https://reader034.vdocuments.us/reader034/viewer/2022042420/5f36ff427a75be74143d5e7e/html5/thumbnails/2.jpg)
www.vektek.com 800-992-0236 © Vektek, April 2019
TuffCam™ Swing Clamps were developed to meet your demand for high-speed, precise positioning and/or heavy arm applications. These tri-cam design clamps can position and clamp in less than one second and handle larger arms than VersaCam™ Swing Clamps. One of the keys to this innovation is the patented Cam Follower Ball Seat that was developed to improve strength and wear. Using the patented Vektek V-Groove technology, a Tungsten Carbide ball for strength and wear and an elastomer spring, these clamps have reduced static friction for improved clamp breakaway and reduced dynamic friction for improved life.
nAvailable in these body configurations - Threaded Body - Top Flange - Top Flange Long Stroke - Bottom Flange - Bottom Flange Long Stroke - Cartridge Mount - Rod Position Sensing - Magnetic Position Sensing - Low Profile Top Flange - Low Profile Bottom Flange - Low Profile Rod Position Sensing - Low Profile Magnetic Position SensingnSingle and double acting (position sensing are double acting only).n Three cams for more accurate arm positioning, smoother rotation and lower per cam surface contact pressure.n Patented ball seat for improved rotary function, cam follower contact and reduced dynamic and static friction.nBHC™ (Black Hard Coating) on the cylinder bodies helps prevent scoring and scratching.n Standard fluorocarbon wipers for improved coolant compatibility.n Arm clocking feature uses standard Vektek arms.n Same mounting envelope as Standard VektorFlo® Swing Clamps.
TuffCam™ Clamp Time and Fluid Flow Rates
Swing Clamp
Capacity(lbs)
Standard Arm Extended ArmFastest
AllowableClamp Time(sec.)
Max. Permissible
Flow Rate
(cu. in./min)
Fastest Allowable
Clamp Time (sec.)
Max. Permissible
Flow Rate
(cu. in./min)450 0.2 17 0.5 7
1100 0.3 47 0.7 202600 0.4 109 0.8 545000 0.5 235 1.0 117
Low Profile TuffCam™5000 0.5 155 1.0 787500 0.5 251 1.0 126
ILS150108 REV G
TuffCam™ Swing Clamp Arm Clocking Feature Drill points shown in the clamped position.
6 Clocking features 60° apart.
TuffCam™ Cam Follower Design - Three cams for more accurate arm positioning, smoother rotation and lower per cam surface contact pressure - Composite ball seat improves rotary function, cam follower contact and reduces friction - Tungsten carbide ball material
The flows in the table are maximum recommendations and clamp times are minimum recommendations.- For upreach and double arms, use extended arm flows and times.- When using custom arms the extended arm flows and times are to be considered the limiting factor.- The actual time to position the clamp will vary by custom arm configuration and may require customer testing in specific application to establish limits.
C-2
TuffCam™ Swing Clamps
Features, Clocking, Clamp Time and Flow Rates
![Page 3: TuffCam™ Swing Clamps - VektekWhat makes the cam follower ball seat so special in these units? The three cams and cam balls guide the rotation of the plunger providing greater support](https://reader034.vdocuments.us/reader034/viewer/2022042420/5f36ff427a75be74143d5e7e/html5/thumbnails/3.jpg)
© Vektek, April 2019 800-992-0236 www.vektek.com
DimensionsSingle Acting Model No.
Double Acting Model No.
Clamp Capacity (lbs)
A B C D E F G H J N P S T V W Z AC AD14-0105-01- L, R, S 14-0205-01- L, R, S 450 1 1/16-16 4.28 4.02 2.02 0.94 0.75 0.27 0.437 1/4-28 X 0.38 0.57 1.13 0.81 1.50 0.56 N/A 25 SAE 2 0.1314-0109-01- L, R, S 14-0209-01- L, R, S 1100 1 1/2-16 5.68 5.32 2.54 1.27 1.09 0.38 0.625 3/8-24 X 0.63 0.79 1.50 1.03 1.88 0.78 0.09 35 SAE 4 0.1914-0113-01- L, R, S 14-0213-01- L, R, S 2600 1 7/8-16 7.33 6.81 3.35 1.30 1.06 0.36 0.875 1/2-20 X 0.75 1.16 1.88 1.20 2.25 0.97 0.08 30 SAE 4 0.19
WARNING! Never allow swing arm to contact workpiece or fixture during arm rotation. ** Cylinder capacities are listed at 5,000 psi maximum operating pressure, with a standard length VektorFlo® arm installed. Minimum operating pressure is 750 psi for single acting, 500 psi for double acting. The clamping force is adjustable by varying the hydraulic system pressure. To determine the approximate output force for your application, divide the cylinder capacity shown above by 5,000, and multiply the resultant number by your system operating pressure to obtain the approximate clamping force for your application. (Actual force will vary slightly due to internal cantilever loading, friction loss and/or return springs.)*** To allow for piece part height variations, it is recommended that the vertical travel be set at about 50% of the vertical stroke. **** To ensure maximum service life and trouble-free operation, restrict fluid flow per table on page C-2.
Model No.
Clamp Swing
Direction
Cylinder Capacity
(lbs)**
Vertical Clamp Stroke (in)***
Total Stroke(Swing
+ Vertical)
BodyThread
Standard Arm
Length**
Effective Piston Area
(sq. in.)
OilCapacity (cu. in.)****
Retract Extend RetractSingle Acting (S/A) Cylinders, actuated hydraulically 1 direction, spring returned.14-0105-01-R Right
450.22
0.57 1 1/16-16 1.06 0.098 N/A 0.05614-0105-01-L Left .2214-0105-01-S Straight .5714-0109-01-R Right
1,100.31
0.79 1 1/2-16 1.50 0.295 N/A 0.23314-0109-01-L Left .3114-0109-01-S Straight .7914-0113-01-R Right
2,600.50
1.16 1 7/8-16 2.00 0.626 N/A 0.72614-0113-01-L Left .5014-0113-01-S Straight 1.16Double Acting (D/A) Cylinders, actuated hydraulically both directions.14-0205-01-R Right
450.22
0.57 1 1/16-16 1.06 0.098 0.142 0.05614-0205-01-L Left .2214-0205-01-S Straight .5714-0209-01-R Right
1,100.31
0.79 1 1/2-16 1.50 0.295 0.475 0.23314-0209-01-L Left .3114-0209-01-S Straight .7914-0213-01-R Right
2,600.50
1.16 1 7/8-16 2.00 0.626 1.423 0.72614-0213-01-L Left .5014-0213-01-S Straight 1.16
U. S. Patent No. 7,032,897
ILS140001 REV M
SWING CLAMP PLUNGER SHOWN IN THE EXTENDED LH CAM POSITION
SINGLE ACTING DOUBLE ACTING
Single And Double Actingn Available in three capacities 450, 1,100 and 2,600 lbs. n Three cams for accurate arm positioning, smoother rotation and lower per cam surface contact pressure.n Patented ball seat for improved rotary function, cam follower contact and reduced dynamic and static friction.n Fluorocarbon wipers are standard for improved coolant compatibility.nStandard swing is 90°; swing angles less than 90° require Swing Restrictors. Swings angles greater than 90°are special order products.n To avoid cylinder damage and preserve warranty, use recommended flow rate limits and time calculations on page C-2.n Tungsten Carbide ball for improved strength and wear.n Same mounting envelope as VersaCam™ Swing Clamps.n Arms sold separately – see Section O.
C-3
TuffCam™ Swing Clamps
Threaded Body
![Page 4: TuffCam™ Swing Clamps - VektekWhat makes the cam follower ball seat so special in these units? The three cams and cam balls guide the rotation of the plunger providing greater support](https://reader034.vdocuments.us/reader034/viewer/2022042420/5f36ff427a75be74143d5e7e/html5/thumbnails/4.jpg)
www.vektek.com 800-992-0236 © Vektek, April 2019
DimensionsSingle Acting Model No.
Double Acting Model No.
Clamp Capacity (lbs)
A B C D E F G H J N P S T V W Z AC AD14-0105-01- L, R, S 14-0205-01- L, R, S 450 1 1/16-16 4.28 4.02 2.02 0.94 0.75 0.27 0.437 1/4-28 X 0.38 0.57 1.13 0.81 1.50 0.56 N/A 25 SAE 2 0.1314-0109-01- L, R, S 14-0209-01- L, R, S 1100 1 1/2-16 5.68 5.32 2.54 1.27 1.09 0.38 0.625 3/8-24 X 0.63 0.79 1.50 1.03 1.88 0.78 0.09 35 SAE 4 0.1914-0113-01- L, R, S 14-0213-01- L, R, S 2600 1 7/8-16 7.33 6.81 3.35 1.30 1.06 0.36 0.875 1/2-20 X 0.75 1.16 1.88 1.20 2.25 0.97 0.08 30 SAE 4 0.19
H
D
CB
F
.156±.005
G
P
S TYP
T
2x Z
J PLUNGER THREAD
ATHREAD
E
N TOTAL STROKEM CLAMP STROKE
WTYP
V
ILS140002 REV K
SWING CLAMP PLUNGER SHOWN IN THE EXTENDED LH CAM POSITION
ORDER ARMSEPARATELY
6x AD x 90ARM CLOCKING FEATURE
AC CLAMP PORTAC PORTUNCLAMP- D/A VENT- S/A,BREATHER PROVIDED
Order arms separately.
FeaturesBHC™ (Black Hard Coating) on the cylinder bodies helps prevent scoring and scratching.
SAE porting is all on the top of the cylinder body for easy access (bottom unclamp porting is available).
Vent port with bronze filter gives single acting Swing Clamps a place to “breathe” and helps keep out contamination.
Single Acting Model No.
Double Acting Model No. M
14-0105-01-L 14-0205-01-L .2214-0105-01-R 14-0205-01-R .2214-0105-01-S 14-0205-01-S .5714-0109-01-L 14-0209-01-L .3114-0109-01-R 14-0209-01-R .3114-0109-01-S 14-0209-01-S .7914-0113-01-L 14-0213-01-L .5014-0113-01-R 14-0213-01-R .5014-0113-01-S 14-0213-01-S 1.16
Single Acting Cylinders, actuated hydraulically one direction, spring returned.
Double Acting Cylinders, actuated hydraulically both directions.
C-4
TuffCam™ Swing Clamps
Threaded Body
![Page 5: TuffCam™ Swing Clamps - VektekWhat makes the cam follower ball seat so special in these units? The three cams and cam balls guide the rotation of the plunger providing greater support](https://reader034.vdocuments.us/reader034/viewer/2022042420/5f36ff427a75be74143d5e7e/html5/thumbnails/5.jpg)
© Vektek, April 2019 800-992-0236 www.vektek.com
DimensionsSingle Acting Model No.
Double Acting Model No.
Clamp Capacity (lbs)
A B C D E F G H J K L N P Q R S T U V X Y Z AC AD
14-6105-01- L, R, S 14-6205-01- L, R, S 450 .99 4.28 4.02 2.02 .94 .75 .31 .437 1/4-28 X .38 .22 .63 .57 1.88 .80 .22 .96 1.58 .31 .58 .69 .44
28
SAE 2 .1314-6109-01- L, R, S 14-6209-01- L, R, S 1100 1.43 5.68 5.32 2.60 1.21 1.03 .38 .625 3/8-24 X .63 .28 .84 .79 2.31 1.03 .34 1.24 2.08 .50 .76 .88 .56 SAE 4 .1914-6113-01- L, R, S 14-6213-01- L, R, S 2600 1.74 7.34 6.82 3.35 1.30 1.06 .41 .875 1/2-20 X .75 .34 1.05 1.16 2.69 1.25 .44 1.53 2.53 .41 .90 1.00 .53 SAE 4 .1914-6118-02- L, R, S 14-6218-02- L, R, S 5000 2.37 9.92 9.29 4.41 1.80 1.47 .54 1.250 5/8-18 X .75 .41 1.41 1.65 3.61 1.72 .60 2.05 3.34 .75 1.21 1.37 .75 SAE 4 .19
Model No.
Clamp Swing
Direction
Cylinder Capacity
(lbs)**
Vertical Clamp Stroke (in.)***
Total Stroke(Swing
+ Vertical)
BodyDia.
Standard Arm
Length**
Effective Piston Area
(sq. in.)
OilCapacity (cu. in.)****
Port X Depth For Optional
In-Port Valves*****Retract Extend Retract
Single Acting (S/A) Cylinders, actuated hydraulically 1 direction, spring returned.14-6105-01-R Right
450.22
0.57 0.99 1.06 0.098 N/A 0.056 SAE 2 X .4814-6105-01-L Left .2214-6105-01-S Straight .5714-6109-01-R Right
1,100.31
0.79 1.43 1.50 0.295 N/A 0.233 SAE 4 X .5814-6109-01-L Left .3114-6109-01-S Straight .7914-6113-01-R Right
2,600.50
1.16 1.74 2.00 0.626 N/A 0.726 SAE 4 X .5814-6113-01-L Left .5014-6113-01-S Straight 1.1614-6118-02-R Right
5,000.62
1.65 2.37 2.50 1.178 N/A 1.955 SAE 4 X .7514-6118-02-L Left .6214-6118-02-S Straight 1.65Double Acting (D/A) Cylinders, actuated hydraulically both directions.14-6205-01-R Right
450.22
0.57 0.99 1.06 0.098 0.142 0.056 SAE 2 X .4814-6205-01-L Left .2214-6205-01-S Straight .5714-6209-01-R Right
1,100.31
0.79 1.43 1.50 0.295 0.475 0.233 SAE 4 X .5814-6209-01-L Left .3114-6209-01-S Straight .7914-6213-01-R Right
2,600.50
1.16 1.74 2.00 0.626 1.423 0.726 SAE 4 X .5814-6213-01-L Left .5014-6213-01-S Straight 1.1614-6218-02-R Right
5,000.62
1.65 2.37 2.50 1.178 3.992 1.955 SAE 4 X .7514-6218-02-L Left .6214-6218-02-S Straight 1.65
Single And Double Actingn Three cams for accurate arm positioning, smoother rotation and lower per cam surface contact pressure.n Patented ball seat for improved rotary function, cam follower contact, reduced dynamic and static friction.n Fluorocarbon wipers are standard for improved coolant compatibility.n Tungsten Carbide ball material for strength and wear.n Same mounting envelope as standard VektorFlo® Swing Clamps.n Manifold fitting Model No. 30-8711-20, adapter assembly and plugs are included and shipped with the clamp. See Section H. n TuffCam™ Clocking feature (page C-2). n Arms sold separately – see Section O.n Can be manifold mounted or plumbed (use standard SAE). nOptional In-Port Sequence valve is a sequencing device with reverse free flow check valve.
U. S. Patent No. 7,032,897
WARNING! Never allow swing arm to contact workpiece or fixture during arm rotation. ** Cylinder capacities are listed at 5,000 psi maximum operating pressure, with a standard length VektorFlo® arm installed. Minimum operating pressure is 750 psi for single acting, 500 psi for double acting. The clamping force is adjustable by varying the hydraulic system pressure. To determine the approximate output force for your application, divide the cylinder capacity shown above by 5,000, and multiply the resultant number by your system operating pressure to obtain the approximate clamping force for your application. (Actual force will vary slightly due to internal cantilever loading, friction loss and/or return springs.)*** To allow for piece part height variations, it is recommended that the vertical travel be set at about 50% of the vertical stroke.
ILS146001 REV R
SWING CLAMP PLUNGER SHOWN IN THE EXTENDED LH CAM POSITION
SINGLE ACTING DOUBLE ACTING
**** To ensure maximum service life and trouble-free operation, restrict fluid flow per table on page C-2.***** In-Port valves require the use of manifold mount ports.
C-5
TuffCam™ Swing Clamp
Top Flange
![Page 6: TuffCam™ Swing Clamps - VektekWhat makes the cam follower ball seat so special in these units? The three cams and cam balls guide the rotation of the plunger providing greater support](https://reader034.vdocuments.us/reader034/viewer/2022042420/5f36ff427a75be74143d5e7e/html5/thumbnails/6.jpg)
www.vektek.com 800-992-0236 © Vektek, April 2019
DimensionsSingle ActingModel No.
Double ActingModel No.
Clamp Capacity (lbs)
A B C D E F G H J K L N P Q R S T U V X Y Z AC AD
14-6105-01- L, R, S 14-6205-01- L, R, S 450 .99 4.28 4.02 2.02 .94 .75 .31 .437 1/4-28 X .38 .22 .63 .57 1.88 .80 .22 .96 1.58 .31 .56 .69 .44
28
SAE 2 .1314-6109-01- L, R, S 14-6209-01- L, R, S 1100 1.43 5.68 5.32 2.60 1.21 1.03 .38 .625 3/8-24 X .63 .28 .84 .79 2.31 1.03 .34 1.24 2.08 .50 .76 .88 .56 SAE 4 .1914-6113-01- L, R, S 14-6213-01- L, R, S 2600 1.74 7.34 6.82 3.35 1.30 1.06 .41 .875 1/2-20 X .75 .34 1.05 1.16 2.69 1.25 .44 1.53 2.53 .41 .90 1.00 .53 SAE 4 .1914-6118-02- L, R, S 14-6218-02- L, R, S 5000 2.37 9.92 9.29 4.41 1.80 1.47 .54 1.250 5/8-18 X .75 .41 1.41 1.65 3.61 1.72 .60 2.05 3.34 .75 1.21 1.37 .75 SAE 4 .19
A
U
GF
E
D
CB
H
M CLAMP STROKEN TOTAL STROKE
P
X
T
STYP
YQ
R
2x ZL
K THRU3 PLACES
.156
.005
V
ILS146002 REV M
ORDER ARMSEPARATELY
6x AD x 90ARM CLOCKING FEATURE
J PLUNGER THREAD
AC PORTUNCLAMP- D/AVENT- S/A,BREATHER PROVIDED
AC CLAMP OR FLOWCONTROL PORT
BOTTOM CLAMP PORTFOR MANIFOLD MOUNTING(ADAPTER FURNISHED)
BOTTOM UNCLAMP PORTFOR MANIFOLD MOUNTING
(ADAPTER FURNISHED)
SWING CLAMP PLUNGER SHOWN IN THE EXTENDED LH CAM POSITION
Order arms separately.
Mounting DimensionsModel No. A B C D E F G
14-6X05-01- L, R, S 1.015 10-32 0.795 0.219 0.687 0.438 0.62514-6X09-01- L, R, S 1.453 1/4-20 1.032 0.344 0.875 0.562 0.84414-6X13-01- L, R, S 1.765 5/16-18 1.250 0.438 1.000 0.531 1.04714-6X18-02- L, R, S 2.390 3/8-16 1.719 0.601 1.367 0.750 1.406
FeaturesBHC™ (Black Hard Coating) on the cylinder body helps prevent scoring and scratching.
SAE porting is all on the top of the cylinder body for easy access, no need to modify fixtures or reroute tubing to access cylinder end to unclamp. (Optional bottom porting available.)
Vent port with bronze filter gives single acting Swing Clamps a place to “breathe” and helps keep contamination from entering breather port.
A .0102X E .005
2X D .005
2X G .010
2X F .010
C .005
ILS146005 REV C
3X B
.09/.13 CLAMP FEED HOLEFOR MANIFOLD MOUNT
.09/.13 UNCLAMP FEED HOLEFOR DOUBLE ACTING APPLICATIONS
CHAMFER .030 X 45
Single Acting Model No.
Double Acting Model No. M
14-6105-01-L 14-6205-01-L .2214-6105-01-R 14-6205-01-R .2214-6105-01-S 14-6205-01-S .5714-6109-01-L 14-6209-01-L .3114-6109-01-R 14-6209-01-R .3114-6109-01-S 14-6209-01-S .7914-6113-01-L 14-6213-01-L .5014-6113-01-R 14-6213-01-R .5014-6113-01-S 14-6213-01-S 1.1614-6118-02-L 14-6218-02-L .6214-6118-02-R 14-6218-02-R .6214-6118-02-S 14-6218-02-S 1.65
For proper sealing, mating surface must be flat within 0.003 in. with a maximum 63 µin. Ra surface finish.
C-6
TuffCam™ Swing Clamp
Top Flange
![Page 7: TuffCam™ Swing Clamps - VektekWhat makes the cam follower ball seat so special in these units? The three cams and cam balls guide the rotation of the plunger providing greater support](https://reader034.vdocuments.us/reader034/viewer/2022042420/5f36ff427a75be74143d5e7e/html5/thumbnails/7.jpg)
© Vektek, April 2019 800-992-0236 www.vektek.com
Model No.*
Clamp Swing
Direction
Cylinder Capacity
(lbs)**
Vertical Clamp Stroke (in.)***
Total Stroke(Swing
+ Vertical)
BodyDia.
Standard Arm
Length**
Effective Piston Area
(sq. in.)
OilCapacity (cu. in.)****
Port X Depth for Optional
In-Port Valves*****Retract Extend Retract
Double Acting (D/A) Cylinders, actuated hydraulically both directions.14-6209-10-R Right
1,100.75 .75 1.21 1.43 1.50 0.295 0.73 0.36 SAE 4 X .5814-6209-10-L Left
14-6209-10-S Straight 1.2114-6213-10-R Right
2,6001.34 1.34 2.00 1.87 2.00 0.626 2.45 1.25 SAE 4 X .5814-6213-10-L Left
14-6213-10-S Straight 2.00
DimensionsModel No.
Capacity(lbs)
A B C D E F G H J K L N P Q R S T U V X Y Z AC AD
Double Acting (D/A) Cylinders, actuated hydraulically both directions.14-6209-10- L, R, S 1100 1.43 6.93 6.57 3.44 1.21 1.03 0.38 0.625 3/8-24 x 0.63 0.28 0.84 1.21 2.31 1.03 0.34 1.24 2.08 0.50 0.76 0.88 0.56 28 SAE 4 0.1914-6213-10- L, R, S 2600 1.87 9.80 9.28 4.98 1.30 1.06 0.41 0.875 1/2-20 x 0.75 0.34 1.05 2.00 2.71 1.25 0.47 1.53 2.58 0.41 0.95 1.05 0.75 28 SAE 4 0.19
U. S. Patent No. 7,032,897
Double Acting Long Stroken Available in 1,100 and 2,600 lbs capacities.n More than double the vertical clamping stroke for maximum part deviation allowance and swing clearance.n Three cams for accurate arm positioning, smoother rotation and lower per cam surface contact pressure.n Patented ball seat for improved rotary function, cam follower contact and reduced dynamic and static friction.n Fluorocarbon wipers are standard for improved coolant compatibility.n Tungsten Carbide ball material for strength and wear.n TuffCam™ Clocking feature (page C-2) uses standard length Vektek arm.n Arms sold separately – see Section O. nOptional In-Port Flow Control is a meter-in device with reverse free flow check valve. nOptional In-Port Sequence valve is a sequencing device with reverse free flow check valve.
WARNING! Never allow swing arm to contact workpiece or fixture during arm rotation.
* 2,600 lbs Long Stroke are not interchangeable with TuffCam™or VersaCam™Swing Clamp models. Check overall dimensions for correct mounting in fixture. ** Cylinder capacities are listed at 5,000 psi maximum operating pressure, with a standard length VektorFlo® arm installed. Minimum operating pressure is 750 psi for single acting, 500 psi for double acting. The clamping force is adjustable by varying the hydraulic system pressure. To determine the approximate output force for your application, divide the cylinder capacity shown above by 5,000, and multiply the resultant number by your system operating pressure to obtain the approximate clamping force for your application. (Actual force will vary slightly due to internal cantilever loading, friction loss and/or return springs.)*** To allow for piece part height variations, it is recommended that the vertical travel be set at about 50% of the vertical stroke. **** To ensure maximum service life and trouble-free operation, restrict fluid flow per table at the start of Section C.***** In-Port valves require the use of manifold mount ports.
ILS146006 REV H
SWING CLAMP PLUNGER SHOWN IN THE EXTENDED LH CAM POSITION
C-7
TuffCam™ Swing Clamps
Top Flange Long Stroke
![Page 8: TuffCam™ Swing Clamps - VektekWhat makes the cam follower ball seat so special in these units? The three cams and cam balls guide the rotation of the plunger providing greater support](https://reader034.vdocuments.us/reader034/viewer/2022042420/5f36ff427a75be74143d5e7e/html5/thumbnails/8.jpg)
www.vektek.com 800-992-0236 © Vektek, April 2019
DimensionsModel No.
Capacity(lbs)
A B C D E F G H J K L N P Q R S T U V X Y Z AC AD
Double Acting (D/A) Cylinders, actuated hydraulically both directions.14-6209-10- L, R, S 1100 1.43 6.93 6.57 3.44 1.21 1.03 0.38 0.625 3/8-24 x 0.63 0.28 0.84 1.21 2.31 1.03 0.34 1.24 2.08 0.50 0.76 0.88 0.56 28 SAE 4 0.1914-6213-10- L, R, S 2600 1.87 9.80 9.28 4.98 1.30 1.06 0.41 0.875 1/2-20 x 0.75 0.34 1.05 2.00 2.71 1.25 0.47 1.53 2.58 0.41 0.95 1.05 0.75 28 SAE 4 0.19
A
U
G
F
E
D
C
B
H
M CLAMP STROKEN TOTAL STROKE
P
X
T
STYP
YQ
R
2x Z
L
K THRU3 PLACES
.156
.005
V
ILS146007 REV G
ORDER ARMSEPARATELY
6x AD x 90ARM CLOCKING FEATURE
J PLUNGER THREAD
AC UNCLAMP PORT
AC CLAMP OR FLOWCONTROL PORT
BOTTOM CLAMP PORTFOR MANIFOLD MOUNTING(ADAPTER FURNISHED)
BOTTOM UNCLAMP PORTFOR MANIFOLD MOUTING
(ADAPTER FURNISHED)
SWING CLAMP PLUNGER SHOWN IN THE EXTENDED LH CAM POSITION
A .0102X E .005
2X D .005
2X G .010
2X F .010
C .005
ILS146008 REV B
3X B
.09/.13 CLAMP FEED HOLEFOR MANIFOLD MOUNT
.09/.13 UNCLAMP FEED HOLEFOR MANIFOLD MOUNT
CHAMFER .030 X 45
Mounting Dimensions
Model No. A B C D E F G
14-6209-10- L, R, S 1.453 1/4-20 1.032 0.344 0.875 0.562 0.84414-6213-10- L, R, S 1.885 5/16-18 1.250 0.468 1.050 0.750 1.047
For proper sealing, mating surface must be flat within 0.003 in. with a maximum 63 µin. Ra surface finish.
ModelNo. M
14-6209-10-L .7514-6209-10-R .7514-6209-10-S 1.2114-6213-10-L 1.3414-6213-10-R 1.3414-6213-10-S 2.00
C-8
TuffCam™ Swing Clamps
Top Flange Long Stroke
![Page 9: TuffCam™ Swing Clamps - VektekWhat makes the cam follower ball seat so special in these units? The three cams and cam balls guide the rotation of the plunger providing greater support](https://reader034.vdocuments.us/reader034/viewer/2022042420/5f36ff427a75be74143d5e7e/html5/thumbnails/9.jpg)
© Vektek, April 2019 800-992-0236 www.vektek.com
Model No.
Clamp Swing
Direction
Cylinder Capacity
(lbs)**
Vertical ClampStroke (in.)***
Total Stroke(Swing
+ Vertical)
Standard Arm
Length
Effective Piston Area
(sq. in.)
OilCapacity (cu. in.)****
Port X Depth for Optional In-Port Valves
*****Retract Extend RetractSingle Acting (S/A) Cylinders, actuated hydraulically 1 direction, spring returned.14-2105-01-R Right
450.22.22 .57
0.57 1.06 0.098 N/A 0.056 SAE 4 X .5814-2105-01-L Left14-2105-01-S Straight14-2109-01-R Right
1,100.31 .31 .79
0.79 1.50 0.295 N/A 0.233 SAE 4 X .7514-2109-01-L Left14-2109-01-S Straight14-2113-01-R Right
2,600.50 .50
1.161.16 2.00 0.626 N/A 0.726 SAE 4 X .7514-2113-01-L Left
14-2113-01-S Straight14-2118-03-R Right
5,000.62 .62
1.651.65 2.50 1.178 N/A 1.955 SAE 4 X .7514-2118-03-L Left
14-2118-03-S StraightDouble Acting (D/A) Cylinders, actuated hydraulically both directions.14-2205-01-R Right
450.22 .22 .57
0.57 1.06 0.098 0.142 0.056 SAE 4 X .5814-2205-01-L Left14-2205-01-S Straight14-2209-01-R Right
1,100.31 .31 .79
0.79 1.50 0.295 0.475 0.233 SAE 4 X .7514-2209-01-L Left14-2209-01-S Straight14-2213-01-R Right
2,600.50 .50
1.161.16 2.00 0.626 1.423 0.726 SAE 4 X .7514-2213-01-L Left
14-2213-01-S Straight14-2218-03-R Right
5,000.62 .62
1.651.65 2.50 1.178 3.992 1.955 SAE 4 X .7514-2218-03-L Left
14-2218-03-S Straight
Single And Double Actingn Three cams for accurate arm positioning, smoother rotation and lower per cam surface contact pressure.n Patented ball seat for improved rotary function, cam follower contact and reduces both dynamic and static friction.n Fluorocarbon wipers are standard for improved coolant compatibility. n Tungsten Carbide ball material for strength and wear.n TuffCam™ Clocking feature (page C-2) uses standard length Vektek arm.n Arms sold separately – see Section O. nOptional In-Port Flow Control is a meter-in device with reverse free flow check valve. nOptional In-Port Sequence valve is a sequencing device with reverse free flow check valve.
DimensionsSingle Acting Model No.
Double Acting Model No.
Clamp Capacity A B C D E F G H J K L N P Q R T V X Y AC AD
14-2105-01-L, R, S 14-2205-01-L, R, S 450 1.05 4.32 4.06 2.80 2.99 1.00 .66 .438 1/4-28 x 0.375 .22 .38 .57 1.50 1.06 .38 1.73 .53 .59 0.81 SAE 4 0.1314-2109-01-L, R, S 14-2209-01-L, R, S 1,100 1.49 5.70 5.33 3.65 3.83 1.25 .63 .625 3/8-24 x 0.625 .28 .56 .79 2.00 .99 .56 2.41 .75 .81 1.13 SAE 4 0.1914-2113-01-L, R, S 14-2213-01-L, R, S 2,600 1.79 7.35 6.83 4.43 4.67 1.25 .63 .875 1/2-20 x 0.750 .34 .75 1.16 2.50 1.21 .69 2.72 .94 1.00 1.25 SAE 4 0.1914-2118-03-L, R, S 14-2218-03-L, R, S 5,000 2.49 9.92 9.29 5.88 6.20 1.50 .75 1.250 5/8-18 x 0.750 .41 .75 1.65 3.00 1.59 1.06 3.69 1.38 1.19 1.81 SAE 4 0.19
WARNING! Never allow swing arm to contact workpiece or fixture during arm rotation. ** Cylinder capacities are listed at 5,000 psi maximum operating pressure, with a standard length VektorFlo® arm installed. Minimum operating pressure is 750 psi for single acting, 500 psi for double acting. The clamping force is adjustable by varying the hydraulic system pressure. To determine the approximate output force for your application, divide the cylinder capacity shown above by 5,000, and multiply the resultant number by your system operating pressure to obtain the approximate clamping force for your application. (Actual force will vary slightly due to internal cantilever loading, friction loss and/or return springs.)*** To allow for piece part height variations, it is recommended that the vertical travel be set at about 50% of the vertical stroke.
**** To ensure maximum service life and trouble-free operation, restrict fluid flow per table at the start of Section C.***** In-Port valves require the use of manifold mount ports.
ILS142001 REV S
SWING CLAMP PLUNGER SHOWN IN THE EXTENDED LH CAM POSITION
SINGLE ACTING DOUBLE ACTING
C-9
TuffCam™ Swing Clamp
Bottom Flange
![Page 10: TuffCam™ Swing Clamps - VektekWhat makes the cam follower ball seat so special in these units? The three cams and cam balls guide the rotation of the plunger providing greater support](https://reader034.vdocuments.us/reader034/viewer/2022042420/5f36ff427a75be74143d5e7e/html5/thumbnails/10.jpg)
www.vektek.com 800-992-0236 © Vektek, April 2019
DRAWING NOTES: All ports (except breather) are shipped with removable steel plugs installed. O-Ring face seals provided. (SAE 2 ports)* Models 14-2105-01 (L, R, S) and 14-2205-01 (L, R, S) are manifold mountable from the bottom SAE 2 port only. ** When used as manifold mounted, all 5 mounting bolts must be used to assure proper O-Ring face sealing.
DimensionsSingle Acting Model No.
Double Acting Model No.
Clamp Capacity A B C D E F G H J K L N P Q R T V X Y AC AD
14-2105-01-L, R, S 14-2205-01-L, R, S 450 1.05 4.32 4.06 2.80 2.99 1.00 .66 .438 1/4-28 x 0.375 .22 .38 .57 1.50 1.06 .38 1.73 .53 .59 0.81 SAE 4 0.1314-2109-01-L, R, S 14-2209-01-L, R, S 1,100 1.49 5.70 5.33 3.65 3.83 1.25 .63 .625 3/8-24 x 0.625 .28 .56 .79 2.00 .99 .56 2.41 .75 .81 1.13 SAE 4 0.1914-2113-01-L, R, S 14-2213-01-L, R, S 2,600 1.79 7.35 6.83 4.43 4.67 1.25 .63 .875 1/2-20 x 0.750 .34 .75 1.16 2.50 1.21 .69 2.72 .94 1.00 1.25 SAE 4 0.1914-2118-03-L, R, S 14-2218-03-L, R, S 5,000 2.49 9.92 9.29 5.88 6.20 1.50 .75 1.250 5/8-18 x 0.750 .41 .75 1.65 3.00 1.59 1.06 3.69 1.38 1.19 1.81 SAE 4 0.19
A
BC
DF
H
6x L*
G
N TOTAL STROKEM CLAMP STROKE
.156
.005
P
Q
4x R
2x X
4x Y
T
V
E
ILS142002 REV P
AC PORTUNCLAMP- D/A
VENT- S/ABREATHER PROVIDED
AC CLAMP OR FLOWCONTROL PORT
J PLUNGER THREAD
6x AD x 90ARM CLOCKING FEATURE
ORDER ARMSEPARATELY
5x K**
SWING CLAMP PLUNGER SHOWN IN THE EXTENDED LH CAM POSITION
SAE 2 PORT TOP & BOTTOMCLAMPFOR MANIFOLD MOUNTING*
SAE 2 PORT TOP & BOTTOMUNCLAMP / VENT
FOR MANIFOLD MOUNTING*
For proper sealing, mating surface must be flat within 0.003 in. with a maximum 63 µin. Ra surface finish.
Single Acting Model No.
Double Acting Model No. M
14-2105-01-L 14-2205-01-L .2214-2105-01-R 14-2205-01-R .2214-2105-01-S 14-2205-01-S .5714-2109-01-L 14-2209-01-L .3114-2109-01-R 14-2209-01-R .3114-2109-01-S 14-2209-01-S .7914-2213-01-L 14-2213-01-L .5014-2213-01-R 14-2213-01-R .5014-2213-01-S 14-2213-01-S 1.1614-2118-03-L 14-2218-03-L .6214-2118-03-R 14-2218-03-R .6214-2118-03-S 14-2218-03-S 1.65
Single Acting Cylinders, actuated hydraulically one direction, spring returned.
Double Acting Cylinders, actuated hydraulically both directions.
C-10
TuffCam™ Swing Clamp
Bottom Flange
![Page 11: TuffCam™ Swing Clamps - VektekWhat makes the cam follower ball seat so special in these units? The three cams and cam balls guide the rotation of the plunger providing greater support](https://reader034.vdocuments.us/reader034/viewer/2022042420/5f36ff427a75be74143d5e7e/html5/thumbnails/11.jpg)
© Vektek, April 2019 800-992-0236 www.vektek.com
Model No.*
Clamp Swing
Direction
Cylinder Capacity
(lbs)**
Vertical ClampStroke (in.)***
Total Stroke(Swing
+ Vertical)
Standard Arm
Length**
Effective Piston Area
(sq. in.)
OilCapacity (cu. in.)****
Port X Depth for Optional
In-Port Valves*****Retract Extend Retract
Double Acting (D/A) Cylinders, actuated hydraulically both directions.14-2209-10-R Right
1100.75
1.21 1.50 .295 .73 .36 SAE 4 X .7514-2209-10-L Left .75 14-2209-10-S Straight 1.2114-2213-10-R Right
26001.34
2.00 2.00 .626 2.45 1.25 SAE 4 X .7514-2213-10-L Left 1.3414-2213-10-S Straight 2.00
DimensionsModel No.
Capacity(lbs)
A B C D E F G H J K L N P Q R T V X Y AC AD
Double Acting (D/A) 14-2209-10- L, R, S 1,100 1.49 6.97 6.62 4.53 4.70 1.25 0.63 0.625 3/8-24 x 0.625 0.28 0.56 1.21 2.00 0.99 0.56 2.41 0.75 0.81 1.13 SAE 4 0.1914-2213-10- L, R, S 2,600 1.87 9.84 9.34 6.10 6.34 1.25 0.63 0.875 1/2-20 x 0.750 0.34 0.75 2.00 2.50 1.21 0.69 2.72 0.94 1.00 1.25 SAE 4 0.19
Double Acting Long Stroken Available in 1,100 and 2,600 lbs capacities. nOver double the vertical clamping stroke for maximum part deviation allowance and swing clamp clearance.n More than double the vertical clamping stroke for maximum part deviation allowance and swing clearance.n Three cams for accurate arm positioning, smoother rotation and lower per cam surface contact pressure.n Patented ball seat for improved rotary function, cam follower contact and reduced dynamic and static friction.n Fluorocarbon wipers are standard for improved coolant compatibility.n Tungsten Carbide ball material for strength and wear.n TuffCam™Clocking feature (page C-2) uses standard length Vektek arm. nOptional In-Port Flow Control is a meter-in device with reverse free flow check valve. nOptional In-Port Sequence valve is a sequencing device with reverse free flow check valve.n Arms sold separately – see Section O.
U. S. Patent No. 7,032,897
WARNING! Never allow swing arm to contact workpiece or fixture during arm rotation.* 2,600 lbs Long Stroke may not be interchangeable with TuffCam™or VersaCam™Swing Clamp models. Check overall dimensions for correct mounting in fixture.** Cylinder capacities are listed at 5,000 psi maximum operating pressure, with a standard length VektorFlo® arm installed. Minimum operating pressure is 750 psi for single acting, 500 psi for double acting. The clamping force is adjustable by varying the hydraulic system pressure. To determine the approximate output force for your application, divide the cylinder capacity shown above by 5,000, and multiply the resultant number by your system operating pressure to obtain the approximate clamping force for your application. (Actual force will vary slightly due to internal cantilever loading, friction loss and/or return springs.)*** To allow for piece part height variations, it is recommended that the vertical travel be set at about 50% of the vertical stroke. **** To ensure maximum service life and trouble-free operation, restrict fluid flow per table on C-2.***** In-Port valves require the use of manifold mount ports.
ILS142006 REV G
SWING CLAMP PLUNGER SHOWN IN THE EXTENDED LH CAM POSITION
C-11
TuffCam™ Swing Clamps
Bottom Flange Long Stroke
![Page 12: TuffCam™ Swing Clamps - VektekWhat makes the cam follower ball seat so special in these units? The three cams and cam balls guide the rotation of the plunger providing greater support](https://reader034.vdocuments.us/reader034/viewer/2022042420/5f36ff427a75be74143d5e7e/html5/thumbnails/12.jpg)
www.vektek.com 800-992-0236 © Vektek, April 2019
DimensionsModel No.
Capacity(lbs)
A B C D E F G H J K L N P Q R T V X Y AC AD
Double Acting (D/A) 14-2209-10- L, R, S 1,100 1.49 6.97 6.62 4.53 4.70 1.25 0.63 0.625 3/8-24 x 0.625 0.28 0.56 1.21 2.00 0.99 0.56 2.41 0.75 0.81 1.13 SAE 4 0.1914-2213-10- L, R, S 2,600 1.87 9.84 9.34 6.10 6.34 1.25 0.63 0.875 1/2-20 x 0.750 0.34 0.75 2.00 2.50 1.21 0.69 2.72 0.94 1.00 1.25 SAE 4 0.19
For proper sealing, mating surface must be flat within 0.003 in. with a maximum 63 µin. Ra surface finish.
DRAWING NOTES:* All models are shipped with removable steel plugs installed. O-Ring face seals provided.*** All five mounting screws must be used when manifold mounting, to assure a leak-free O-Ring seal.
Model No. M
Double Acting 14-2209-10-L 0.7514-2209-10-R 0.7514-2209-10-S 1.1214-2213-10-L 1.3414-2213-10-R 1.3414-2213-10-S 2.00
A
BC
DF
H
6x L
G
N TOTAL STROKEM CLAMP STROKE
.156
.005
P
Q
4x R
2x X
4x Y
T
V
E
ILS142007 REV J
AC UNCLAMP PORT
AC CLAMP OR FLOWCONTROL PORT
J PLUNGER THREAD
6x AD x 90ARM CLOCKING FEATURE
ORDER ARMSEPARATELY
5x K***
SWING CLAMP PLUNGER SHOWN IN THE EXTENDED LH CAM POSITIONSAE 2 PORT TOP & BOTTOMCLAMPFOR MANIFOLD MOUNTING
SAE 2 PORT TOP & BOTTOMUNCLAMP
FOR MANIFOLD MOUNTING
C-12
TuffCam™ Swing Clamps
Bottom Flange Long Stroke
![Page 13: TuffCam™ Swing Clamps - VektekWhat makes the cam follower ball seat so special in these units? The three cams and cam balls guide the rotation of the plunger providing greater support](https://reader034.vdocuments.us/reader034/viewer/2022042420/5f36ff427a75be74143d5e7e/html5/thumbnails/13.jpg)
© Vektek, April 2019 800-992-0236 www.vektek.com
DimensionsModel No.
Capacity(lbs)
A B C D E F G H J K L M N P R S T V W AC
Single Acting (S/A) Cylinders, actuated hydraulically 1 direction, spring returned.14-1105-01- L,R,S 450 1 1/16-12 4.25 4.00 2.12 0.83 0.63 0.49 0.438 1/4-28 x 0.375 0.92 0.935 0.22 0.57 1.00 1.32 0.13 1.25 N/A N/A Breather14-1109-01- L,R,S 1,100 1 5/8-12 5.66 5.31 2.68 1.13 0.94 0.65 0.625 3/8-24 x 0.625 1.34 1.372 0.31 0.79 1.50 1.50 0.13 1.88 0.02 1.03 Breather14-1113-01- L,R,S 2,600 1 7/8-12 7.32 6.80 3.15 1.49 1.25 0.55 0.875 1/2-20 x 0.750 1.72 1.747 0.50 1.16 1.63 1.50 0.16 2.13 0.02 1.40 Breather
Double Acting (D/A) Cylinders, actuated hydraulically both directions.14-1205-01- L,R,S 450 1 1/6-12 4.25 4.00 2.12 0.83 0.63 0.49 0.438 1/4-28 x 0.375 0.92 0.935 0.22 0.57 1.00 1.32 0.13 1.25 N/A N/A SAE 214-1209-01- L,R,S 1,100 1 5/8-12 5.66 5.31 2.68 1.13 0.94 0.65 0.625 3/8-24 x 0.625 1.34 1.372 0.31 0.79 1.50 1.50 0.13 1.88 0.02 1.03 SAE 414-1213-01- L,R,S 2,600 1 7/8-12 7.32 6.80 3.15 1.49 1.25 0.55 0.875 1/2-20 x 0.750 1.72 1.747 0.50 1.16 1.63 1.50 0.16 2.13 0.02 1.40 SAE 4
Model No.
ClampSwing
Cylinder Capacity
(lbs)**
Vertical ClampStroke (in)***
Total Stroke(Swing
+ Vertical)
BodyThread
Standard Arm
Length
Effective Piston Area
(sq. in.)
OilCapacity (cu. in.)****
Retract Extend RetractSingle Acting (S/A) Cylinders, actuated hydraulically 1 direction, spring returned.14-1105-01-R Right
450.22
0.57 1 1/16-12 1.06 0.098 N/A 0.05614-1105-01-L Left .2214-1105-01-S Straight .5714-1109-01-R Right
1,100.31
0.79 1 5/8-12 1.50 0.295 N/A 0.23314-1109-01-L Left .3114-1109-01-S Straight .7914-1113-01-R Right
2,600.50
1.16 1 7/8-12 2.00 0.626 N/A 0.72614-1113-01-L Left .5014-1113-01-S Straight 1.16
Double Acting (D/A) Cylinders, actuated hydraulically both directions.14-1205-01-R Right
450.22
0.57 1 1/16-12 1.06 0.098 0.142 0.05614-1205-01-L Left .2214-1205-01-S Straight .5714-1209-01-R Right
1,100.31
0.79 1 5/8-12 1.50 0.295 0.475 0.23314-1209-01-L Left .3114-1209-01-S Straight .7914-1213-01-R Right
2,600.50
1.16 1 7/8-12 2.00 0.626 1.423 0.72614-1213-01-L Left .5014-1213-01-S Straight 1.16
Single And Double Actingn Three cams for accurate arm positioning, smoother rotation and lower per cam surface contact pressure.n Patented ball seat for improved rotary function, cam follower contact and reduced dynamic and static friction.n Fluorocarbon wipers are standard for improved coolant compatibility.n Tungsten Carbide ball material for strength and wear. n Same mounting envelope as standard VektorFlo® Swing Clamps.n TuffCam™ Clocking feature (page C-2) uses standard length Vektek arm.n Arms sold separately – see Section O.nSingle acting models must be vented. Do not install in a blind hole.
Only one O-Ring must pass cross porting during installation and only one (not two) port must be passed (but should not touch), reducing the chance of O-Ring damage during in stal la tion.
U. S. Patent No. 7,032,897
WARNING! Never allow swing arm to contact workpiece or fixture during arm rotation. ** Cylinder capacities are listed at 5,000 psi maximum operating pressure, with a standard length VektorFlo® arm installed. Minimum operating pressure is 750 psi for single acting, 500 psi for double acting. The clamping force is adjustable by varying the hydraulic system pressure. To determine the approximate output force for your application, divide the cylinder capacity shown above by 5,000 and multiply the resultant number by your system operating pressure to obtain the approximate clamping force for your application. (Actual force will vary slightly due to internal cantilever loading, friction loss and/or return springs.)*** To allow for piece part height variations, it is recommended that the vertical travel be set at about 50% of the vertical stroke. **** To ensure maximum service life and trouble-free operation, restrict fluid flow per table on page C-2.
ILS141100 REV E
SWING CLAMP PLUNGER SHOWN IN THE EXTENDED LH CAM POSITION
SINGLE ACTING DOUBLE ACTING
C-13
TuffCam™ Swing Clamp
Cartridge Mount
![Page 14: TuffCam™ Swing Clamps - VektekWhat makes the cam follower ball seat so special in these units? The three cams and cam balls guide the rotation of the plunger providing greater support](https://reader034.vdocuments.us/reader034/viewer/2022042420/5f36ff427a75be74143d5e7e/html5/thumbnails/14.jpg)
www.vektek.com 800-992-0236 © Vektek, April 2019
R
S
F
G
H
K
L
ATHREAD
PHEX
E
M CLAMP STROKE
N TOTAL STROKE
V
W
T
BC
DILS141101 REV J
SWING CLAMP PLUNGER SHOWN IN THE EXTENDED LH CAM POSITION
ORDER ARMSEPARATELY
CLAMP OILFEED HOLE
AC PORTVENT- S/A*
UNCLAMP- D/AJ PLUNGER THREAD
NOTE: Flexible honing of the cavity is strongly recommended. Flex-Hone™ is a registered trademark of Brush Research Manufacturing Co. Inc., Los Angeles, CA. Please contact Brush Research for additional information. (323-261-2193)
* Single Acting models must be vented, do not install in blind holes.
DimensionsModel No.
Capacity(lbs)
A B C D E F G H J K L M N P R S T V W AC
Single Acting (S/A) Cylinders, actuated hydraulically 1 direction, spring returned.14-1105-01- L,R,S 450 1 1/16-12 4.25 4.00 2.12 0.83 0.63 0.49 0.438 1/4-28 x 0.375 0.92 0.935 0.22 0.57 1.00 1.32 0.13 1.25 N/A N/A Breather14-1109-01- L,R,S 1,100 1 5/8-12 5.66 5.31 2.68 1.13 0.94 0.65 0.625 3/8-24 x 0.625 1.34 1.372 0.31 0.79 1.50 1.50 0.13 1.88 0.02 1.03 Breather14-1113-01- L,R,S 2,600 1 7/8-12 7.32 6.80 3.15 1.49 1.25 0.55 0.875 1/2-20 x 0.750 1.72 1.747 0.50 1.16 1.63 1.50 0.16 2.13 0.02 1.40 Breather
Double Acting (D/A) Cylinders, actuated hydraulically both directions.14-1205-01- L,R,S 450 1 1/6-12 4.25 4.00 2.12 0.83 0.63 0.49 0.438 1/4-28 x 0.375 0.92 0.935 0.22 0.57 1.00 1.32 0.13 1.25 N/A N/A SAE 214-1209-01- L,R,S 1,100 1 5/8-12 5.66 5.31 2.68 1.13 0.94 0.65 0.625 3/8-24 x 0.625 1.34 1.372 0.31 0.79 1.50 1.50 0.13 1.88 0.02 1.03 SAE 414-1213-01- L,R,S 2,600 1 7/8-12 7.32 6.80 3.15 1.49 1.25 0.55 0.875 1/2-20 x 0.750 1.72 1.747 0.50 1.16 1.63 1.50 0.16 2.13 0.02 1.40 SAE 4
Cavity Dimensions
Model No.
CAThread CB CC CD CE CF
CG DepthCH CJ CK CL CM CN
MIN. MAX.Single Acting (S/A) Cylinders, actuated hydraulically 1 direction, spring returned.
14-1105-01-L,R,S 1 1/16-12 1.38 1.148 0.979 0.137 0.50 0.750 0.906 1.25 0.938 N/A N/A 0.750 0.41714-1109-01-L,R,S 1 5/8-12 2.00 1.713 1.541 0.139 0.68 0.815 0.906 1.50 1.376 N/A N/A 0.815 0.52514-1113-01-L,R,S 1 7/8-12 2.25 1.962 1.792 0.139 0.62 0.875 0.906 1.50 1.751 N/A N/A 0.875 0.403Double Acting (D/A) Cylinders, actuated hydraulically both directions.
14-1205-01-L,R,S 1 1/16-12 1.38 1.148 0.979 0.137 0.50 0.750 0.906 N/A 0.938 2.75 2.25 0.750 0.41714-1209-01-L,R,S 1 5/8-12 2.00 1.713 1.541 0.139 0.68 0.815 0.906 N/A 1.376 3.25 2.75 0.815 0.52514-1213-01-L,R,S 1 7/8-12 2.25 1.962 1.792 0.139 0.62 0.875 0.906 N/A 1.751 3.75 3.25 0.875 0.403
CK MIN. PLATE THICKNESS D/A ONLY
CL HOLE DEPTH D/A ONLY
CN MIN.
CM MAX.CH MIN. PLATE THICKNESS S/A
CB MIN..010 .005
30° *
CC+.005-.000.005 -A-
15°±1°
CE .007
CJ±.001-A-
45°±5°MINOR CD+.010/-.000 CG,
CA THREAD CF MIN..005 -A-
ILS141102 REV F.218±.062 CLAMPSUPPLY FEED HOLE
BLEND CHAMFERTO BORE
S/A BREATHER HOLE LOCATION;D/A EXTEND SUPPLY LOCATION
63
63
* Basic cavity can be formed with a standard (SAE J1926/1 Port Detail) O-Ring Cutter.
* The 30˚ lead in angle is to ensure trouble free seal installation.
C-14
TuffCam™ Swing Clamp
Cartridge Mount
![Page 15: TuffCam™ Swing Clamps - VektekWhat makes the cam follower ball seat so special in these units? The three cams and cam balls guide the rotation of the plunger providing greater support](https://reader034.vdocuments.us/reader034/viewer/2022042420/5f36ff427a75be74143d5e7e/html5/thumbnails/15.jpg)
© Vektek, April 2019 800-992-0236 www.vektek.com
Rod Position Sensing Swing Clamps n Available as TuffCam™ Swing Clamp with capacities of 1,100 lbs. and 2,600 lbs. (excluding Long Stroke models).n Actuator Rod Position System can be used with a mechanical switch or air logic system to detect when clamp is in position.n Actuator rod is concentric to plunger shaft.n Actuator rod moves with the same rotary and linear motion as the plunger.n All TuffCam™ features apply to these units.n TuffCam™ Clocking feature (Section C) uses standard length Vektek arm. nOptional In-Port Flow Control is a meter-in device with reverse free flow check valve. nOptional In-Port Sequence valve is a sequencing device with reverse free flow check valve.
BHC™ (Black Hard Coating) on the cylinder body helps prevent scoring and scratching.
AClamped
LengthCThreadLength
BUnclamped
Length
5/16-24 UNF-2A
ILS140008 REV L
Rod Position Sensing System
Model No.
Clamp Swing
Direction
Cylinder Capacity
(lbs)
A(in.)
B(in.)
C(in.)
Port X Depth for Optional
In-Port Valves*
TuffCam™ Threaded Body (D/A) Cylinders actuated hydraulically both directions
14-0209-01-R-PR Right1,100 3.97 3.18 2.88 N/A
14-0209-01-L-PR Left14-0213-01-R-PR Right
2,600 5.10 3.94 3.63 N/A14-0213-01-L-PR Left
TuffCam™ Top Flange (D/A) Cylinders actuated hydraulically both directions
14-6209-01-R-PR Right1,100 3.97 3.18 2.88
SAE 4 X .5814-6209-01-L-PR Left14-6213-01-R-PR Right
2,600 5.10 3.94 3.6314-6213-01-L-PR Left
TuffCam™ Bottom Flange (D/A) Cylinders actuated hydraulically both directions
14-2209-01-R-PR Right1,100 3.92 3.13 2.88
SAE 4 X .7514-2209-01-L-PR Left14-2213-01-R-PR Right
2,600 5.04 3.88 3.6314-2213-01-L-PR Left
* In-Port valves require the use of manifold mount ports.
C-15
TuffCam™ Swing Clamp
Rod Position Sensing
![Page 16: TuffCam™ Swing Clamps - VektekWhat makes the cam follower ball seat so special in these units? The three cams and cam balls guide the rotation of the plunger providing greater support](https://reader034.vdocuments.us/reader034/viewer/2022042420/5f36ff427a75be74143d5e7e/html5/thumbnails/16.jpg)
www.vektek.com 800-992-0236 © Vektek, April 2019
Magnetic Position Sensing Swing Clampsn Available as TuffCam™ Swing Clamps 450, 1,100 and 2,600 lbs (excludes Long Stroke models). n Sensors sold separately. n Sensor mounting housing is concentric to plunger shaft.n For use with Double Acting clamps only.n TuffCam™ Clocking feature uses standard length Vektek arm at the start of Section C. nOptional In-Port Flow Control is a meter-in device with reverse free flow check valve. nOptional In-Port Sequence valve is a sequencing device with reverse free flow check valve.
Sensor Kits Ordered Separately
62-2970-00 PNP Position Sensing Kit includes: a 29-7001-00 Sensor and a 27-6424-00 Cord set
62-2970-01 NPN Position Sensing Kit includes: a 29-7001-01 Sensor and a 27-6424-00 Cord set
The use of NPN or PNP is determined by the type of control unit to which the sensor is connected. One Sensor is required for each sensing position.
Magnetic Position Sensing System
Model No.
Clamp Swing
Direction
Cylinder Capacity
(lbs)
A(in.)
B(in.)
Port X Depth for Optional
In-Port Valves*
TuffCam™ Threaded Body (D/A) Cylinders actuated hydraulically both directions
14-0205-01-R-PS Right 450 1.72 1.00 N/A14-0205-01-L-PS Left14-0209-01-R-PS Right 1,100 1.89 1.00 N/A14-0209-01-L-PS Left14-0213-01-R-PS Right 2,600 2.27 1.00 N/A14-0213-01-L-PS Left
TuffCam™ Top Flange (D/A) Cylinders actuated hydraulically both directions
14-6205-01-R-PS Right 450 1.72 1.00 SAE 2 X .4814-6205-01-L-PS Left14-6209-01-R-PS Right 1,100 1.89 1.00
SAE 4 X .5814-6209-01-L-PS Left14-6213-01-R-PS Right 2,600 2.27 1.0014-6213-01-L-PS Left
TuffCam™ Bottom Flange (D/A) Cylinders actuated hydraulically both directions
14-2205-01-R-PS Right450 1.66 1.00 SAE 4 X .58
14-2205-01-L-PS Left14-2209-01-R-PS Right
1,100 1.84 1.00SAE 4 X .75
14-2209-01-L-PS Left14-2213-01-R-PS Right
2,600 2.21 1.0014-2213-01-L-PS Left
Sensor Feature: - Normally Open Contact - LED Indicator Light - 10 to 30 VDC operating range - 3 Watt Maximum Contact Rating - ≤ 0.8 ms Switch-off time - ≤ 1.0 ms Switch-on time
* In-Port valves require the use of manifold mount ports.
A
B
APPROX. 196 in.CORDSET
APPROX. 15.5 in.SENSOR
BN
BK
BU
+
-
BNBK
BU
+
-PNP
NPN1
4
3
1
4
3
MODEL NO. 62-2970-00SCHEMATIC
MODEL NO. 62-2970-01SCHEMATIC
NON-CONTROLLABLE)(RADIAL ORIENTATION IS
T-SLOT FOR SENSOR
ILS140009 REV Q
C-16
TuffCam™ Swing Clamp
Magnetic Position Sensing
![Page 17: TuffCam™ Swing Clamps - VektekWhat makes the cam follower ball seat so special in these units? The three cams and cam balls guide the rotation of the plunger providing greater support](https://reader034.vdocuments.us/reader034/viewer/2022042420/5f36ff427a75be74143d5e7e/html5/thumbnails/17.jpg)
© Vektek, April 2019 800-992-0236 www.vektek.com
Vektek’s TuffCam™ Low Profile Swing Clamps meet your demand for speed, precise positioning, heavy arm applications and/or clamping capacity up to 7,500 lbs. These Low Profile tri-cam design clamps, with their exclusive Cam Follower Seat, can position and clamp in one second or less and handle large arms with ease. Each clamp includes the Clocking feature that dramatically reduces the time it takes to change arms for maintenance, replacement or fixture setup. One of the keys to this TuffCam™ innovation is the Cam Follower Ball Seat that was developed to improve strength and wear. Using the Vektek patented V-Groove technology, tungsten carbide ball material for strength and wear and a stainless steel spring, these clamps have reduced static friction for improved clamp breakaway and extended life.
nAvailable in these body styles: - Top Flange - Top Flange Long Stroke (Double Acting Only) - Bottom Flange - Rod Position Sensing - Magnetic Position SensingnSingle and double acting models available. The single acting models have increased spring forces for positive return in higher backpressure applications. nBHC™ (Black Hard Coating) on the cylinder bodies helps prevent scoring and scratching.n Standard fluorocarbon wipers for improved coolant compatibility.n Arm clocking feature uses standard Vektek arms.
n Three cams for more accurate arm positioning, smoother rotation and lower per cam surface contact pressure. n Patented stainless steel ball seat for improved rotary function, cam follower contact and reduced dynamic and static friction.
nIncreased cam groove contact force provided by stainless steel spring.nBall material of Tungsten carbide, one of the world’s hardest materials.
TuffCam™ Low Profile Swing Clamp Cam Follower Design
TuffCam™ Low Profile Swing Clamps
* Tougher Cams* Stronger Single Acting Springs * Precise Swing Angle* Clocking Feature
C-17
TuffCam™ Swing Clamps
Low Profile Features
![Page 18: TuffCam™ Swing Clamps - VektekWhat makes the cam follower ball seat so special in these units? The three cams and cam balls guide the rotation of the plunger providing greater support](https://reader034.vdocuments.us/reader034/viewer/2022042420/5f36ff427a75be74143d5e7e/html5/thumbnails/18.jpg)
www.vektek.com 800-992-0236 © Vektek, April 2019
Clamp Time and Fluid Flow Rates for TuffCam™
Swing Clamp
Capacity(lbs)
Standard Arm Extended Arm
Fastest Allowable
Clamp Time(sec.)
Maximum PermissibleFlow Rate (cu. in./min.)
Fastest Allowable
Clamp Time (sec.)
Maximum PermissibleFlow Rate (cu. in./min.)
5000 0.5 155 1.0 787500 0.5 251 1.0 126
NOTE: Arm Length and Pressure Limitation Graphs in Section O. ILS150108 REV G
The above flows are maximum recommendations and clamp times are minimum recommendations.- For upreach and double arms, use extended arm flows and times.- When using custom arms the extended arm flows and times are to be considered the limiting factor.- The actual time to position the clamp will vary by custom arm configuration and may require customer testing in specific application to establish limits.
TuffCam™ Low Profile Swing Clamp Arm Clocking FeatureViews shown apply to double and single acting TuffCam™ Top Flange and Bottom Flange models.Three counter sunk Ø .19 x 90˚ Clocking Feature drill points are shown in the clamped position.
The three (3) Clocking Features are equally spaced 120˚.
TuffCam™ Clocking Features Three clocking features have been added to Vektek’s Low Profile Swing Clamp line. Customers have requested the clocking features to help improve and speed-up arm changes. A drill point on each clamp standardizes arm location at a particular position. An additional two orientation drill points reside 120° out from that position and each other. Access to the positioning feature is through the back or side of the arm, making modification a snap for users. Each arm position can have its own specification.
VektekSwing RestrictorsPage C-32
45º
60º
30º
90º
CLAMPPOSITION
C-18
TuffCam™ Swing Clamp
Low Profile Clamp Time and Flow Rates, Low Profile Clocking
![Page 19: TuffCam™ Swing Clamps - VektekWhat makes the cam follower ball seat so special in these units? The three cams and cam balls guide the rotation of the plunger providing greater support](https://reader034.vdocuments.us/reader034/viewer/2022042420/5f36ff427a75be74143d5e7e/html5/thumbnails/19.jpg)
© Vektek, April 2019 800-992-0236 www.vektek.com
Dimensions
Model No. A B D E F G H J K L N P R T U V X Y Z AC AD AE AF AGSingle Acting (S/A) Cylinders, actuated hydraulically 1 direction, spring returned.
14-0518-0X 2.47 7.71 3.131.31 .99
.49 1.250N/A
.42 .57 1.10 2.79 1.08 3.37 .50 1.40 1.08 1.38.51 SAE 4 N/A N/A
3/8-24 X 1.00 1.2514-0521-0X 3.03 8.52 3.50 .51 1.500 .53 .71 1.18 3.50 1.38 3.94 .49 1.75 1.38 1.63 1/2-20 X 1.25 1.55
Double Acting (D/A) Cylinders, actuated hydraulically both directions.14-0618-0X 2.47 7.30 3.13
1.31 .99.49 1.250 M16 X 2.0
DEEP 0.75.42 .57 1.10 2.79 1.08 3.37 .50 1.40 1.08 1.38
.51 SAE 41.05
.503/8-24 X 1.00
N/A14-0621-0X 3.03 7.74 3.50 .51 1.500 .53 .71 1.18 3.50 1.38 3.94 .49 1.75 1.38 1.63 1.28 1/2-20 X 1.25
Double Acting (D/A) Long Stroke Cylinders, actuated hydraulically both directions.14-0618-0X 2.47 8.67 3.82 1.30
.99.49 1.250 M16 X 2.0
DEEP 0.75.42 .57 1.79 2.79 1.08 3.37 .50 1.40 1.08 1.38
.51 SAE 41.05
.503/8-24 X 1.00
N/A14-0621-0X 3.03 8.99 4.12 1.31 .51 1.500 .53 .71 1.81 3.50 1.38 3.94 .49 1.75 1.38 1.63 1.28 1/2-20 X 1.25
Model No.
Clamp Swing
Direction
Cylinder Capacity
(lbs)*
Vertical ClampStroke (in.)**
Total Stroke(Swing
+ Vertical)
Std. Arm
Length
Effective Piston Area
(sq. in.)
OilCapacity (cu. in.)***
Port X Depth for Optional In-Port Valves
****Extend Retract Extend RetractSingle Acting (S/A) Cylinders, actuated hydraulically 1 direction, spring returned.14-0518-00 Right
5,000.56
1.10 2.50 N/A 1.184 N/A 1.295 SAE 4 X .7514-0518-01 Left .5614-0518-02 Straight 1.1014-0521-00 Right
7,500.62
1.18 2.68 N/A 1.787 N/A 2.092 SAE 4 X .7514-0521-01 Left .6214-0521-02 Straight 1.18
Double Acting (D/A) Cylinders, actuated hydraulically both directions.14-0618-00 Right
5,000.56
14-0618-01 Left .56 1.10 2.50 2.411 1.184 2.647 1.295 SAE 4 X .7514-0618-02 Straight 1.1014-0621-00 Right
7,500.62
1.18 2.68 3.553 1.787 4.177 2.092 SAE 4 X .7514-0621-01 Left .6214-0621-02 Straight 1.18Double Acting (D/A) Long Stroke Cylinders, actuated hydraulically both directions.14-0618-03 Right
5,0001.25
14-0618-04 Left 1.25 1.79 2.50 2.411 1.184 4.351 2.130 SAE 4 X .7514-0618-05 Straight 1.7914-0621-03 Right
7,5001.25
1.81 2.68 3.553 1.787 6.407 3.209 SAE 4 X .7514-0621-04 Left 1.2514-0621-05 Straight 1.81
Warning! Never allow swing arm to contact workpiece or fixture during arm rotation.* Cylinder capacities are listed at 5,000 psi maximum operating pressure, with a standard length VektorFlo® arm installed. Minimum operating pressure is 750 psi for single acting, 500 psi for double acting. The clamping force is adjustable by varying the hydraulic system pressure. To determine the approximate output force for your application, divide the cylinder capacity shown above by 5,000, and multiply the resultant number by your system operating pressure to obtain the approximate clamping force for your application. (Actual force will vary slightly due to internal cantilever loading, friction loss and/or return springs.)** To allow for piece part height variations, it is recommended that the vertical travel be set to about 50% of the vertical stroke.*** To ensure maximum service life and trouble-free operation, restrict fluid flow.**** In-port flow control requires the use of manifold mount ports.
nSingle Acting models have increased spring force for positive return in higher backpressure applications. nManifold and SAE mounting capability.nLow Profile Swing Clamp Arm dimensions are found in Section O.nOne piece body construction reduces potential leak paths and improves rigidity.nTungsten Carbide material for strength and wear.n TuffCam™ Low Profile Clocking feature uses standard length Vektek arm.nOptional In-Port flow control is a meter-in device with reverse free flow check valve. nOptional In-Port Sequence valve is a sequencing device with reverse free flow check valve.
5,000 lbs Capacity - Straight PullNEW! Available in all models!
ILS140020 REV G
Single Acting Double Acting
TuffCam™ Swing Clamp
Low Profile Top Flange
C-19
![Page 20: TuffCam™ Swing Clamps - VektekWhat makes the cam follower ball seat so special in these units? The three cams and cam balls guide the rotation of the plunger providing greater support](https://reader034.vdocuments.us/reader034/viewer/2022042420/5f36ff427a75be74143d5e7e/html5/thumbnails/20.jpg)
www.vektek.com 800-992-0236 © Vektek, April 2019
X
4x K***
Y
L
R
E
N TOTAL STROKE
M CLAMP STROKE
A
2X120
AED/A ONLY
H
GF
B
V
T
ADD/A ONLY
P
3X .42CLOCKINGFEATURE
REFERENCE ARMCROSSBOLT DIMENSION
Z
B
.23,SPANNER WRENCHHOLE .19
U
D
R
AG
X
L
Y
Z
ILS140021 REV E
SWING CLAMP PLUNGER SHOWN IN THE EXTENDED STRAIGHT CAM POSITIONWRENCH FLAT (AD) ORIENTATION NOT CONTROLLED
JD/A ONLY
ORDER ARMSSEPARATELY
D/A PLUNGER END,SHOWN WITH STANDARD ARM
3X .190 x 90ARM CLOCKING FEATURE
AC* CLAMPOR FLOWCONTROL PORT
AC* PORTUNCLAMP -D/A
VENT -S/ABREATHER PROVIDED
* & **MANIFOLD MOUNT
CLAMP PORT
* & **MANIFOLD MOUNTUNCLAMP PORT
S/A PLUNGER END,SHOWN WITHSTANDARD ARM
Dimensions
Model No. A B D E F G H J K L N P R T U V X Y Z AC AD AE AF AGSingle Acting (S/A) Cylinders, actuated hydraulically 1 direction, spring returned.
14-0518-0X 2.47 7.71 3.131.31 .99
.49 1.250N/A
.42 .57 1.10 2.79 1.08 3.37 .50 1.40 1.08 1.38.51 SAE 4 N/A N/A
3/8-24 X 1.00 1.2514-0521-0X 3.03 8.52 3.50 .51 1.500 .53 .71 1.18 3.50 1.38 3.94 .49 1.75 1.38 1.63 1/2-20 X 1.25 1.55
Double Acting (D/A) Cylinders, actuated hydraulically both directions.14-0618-0X 2.47 7.30 3.13
1.31 .99.49 1.250 M16 X 2.0
DEEP 0.75.42 .57 1.10 2.79 1.08 3.37 .50 1.40 1.08 1.38
.51 SAE 41.05
.503/8-24 X 1.00
N/A14-0621-0X 3.03 7.74 3.50 .51 1.500 .53 .71 1.18 3.50 1.38 3.94 .49 1.75 1.38 1.63 1.28 1/2-20 X 1.25
Double Acting (D/A) Long Stroke Cylinders, actuated hydraulically both directions.14-0618-0X 2.47 8.67 3.82 1.30
.99.49 1.250 M16 X 2.0
DEEP 0.75.42 .57 1.79 2.79 1.08 3.37 .50 1.40 1.08 1.38
.51 SAE 41.05
.503/8-24 X 1.00
N/A14-0621-0X 3.03 8.99 4.12 1.31 .51 1.500 .53 .71 1.81 3.50 1.38 3.94 .49 1.75 1.38 1.63 1.28 1/2-20 X 1.25
* All ports (except breather), are shipped with removable steel plugs installed.** Counter bores for Ø 7/16 x 1/16 (2-011) O-Ring face seals provided.*** When used as manifold mounted, all four mounting bolts must be used to assure proper O-Ring face sealing. Recommended fastener sizes are listed in column AF.
4X D .005
Clamp Feed Hole For Manifold Mounting
.110 .020
Unclamp/VentFeed Hole For Manifold Mounting
.110 .020
A .010 Fixture Hole
Thread4X B
4X C .005 2X E .010
2X F .010
ILS140023 REV B
Chamfer Fixture Hole45 X .015 Max.
Mounting DimensionsModel No. A B C D E F
14-0518-0X14-0618-0X 2.496 3/8-24 UNF
↧ .59 1.080 1.080 1.381 .572
14-0521-0X14-0621-0X 3.056 1/2-20 UNF
↧ .78 1.380 1.380 1.630 .713
Model No. M
14-0518-00/01 .5614-0518-02 1.10
14-0521-00/01 .6214-0521-02 1.18
14-0618-00/01 .5614-0618-02 1.10
14-0621-00/01 .62
14-0621-02 1.1814-0618-03/04 1.25
14-0618-05 1.7914-0621-03/04 1.25
14-0621-05 1.81
For proper sealing, mating surface must be flat within 0.003 in. with a maximum 63 µin. Ra surface finish.
C-20
TuffCam™ Swing Clamp
Low Profile Top Flange
![Page 21: TuffCam™ Swing Clamps - VektekWhat makes the cam follower ball seat so special in these units? The three cams and cam balls guide the rotation of the plunger providing greater support](https://reader034.vdocuments.us/reader034/viewer/2022042420/5f36ff427a75be74143d5e7e/html5/thumbnails/21.jpg)
© Vektek, April 2019 800-992-0236 www.vektek.com
WARNING! Never allow swing arm to contact workpiece or fixture during arm rotation.* Cylinder capacities are listed at 5,000 psi maximum operating pressure, with a standard length VektorFlo® arm installed. Minimum operating pressure is 750 psi for single acting, 500 psi for double acting. The clamping force is adjustable by varying the hydraulic system pressure. To determine the approximate output force for your application divide the cylinder capacity shown above by 5,000, and multiply the resultant number by your system operating pressure to obtain the approximate clamping force for your application. (Actual force will vary slightly due to internal cantilever loading, friction loss and/or return springs.) ** To allow for piece part height variations, it is recommended that the vertical travel be set to about 50% of the vertical stroke.*** To ensure maximum service life and trouble-free operation, restrict fluid flow per table at the end of Section C.**** In-Port Valves require the use of manifold mount ports.
Model No.
Clamp Swing
Direction
Cylinder Capacity
(lbs)*
Vertical Clamp Stroke (in.)**
Total Stroke(Swing
+ Vertical)
Std. Arm
Length
Effective Piston Area
(sq. in.)
OilCapacity (cu. in.)***
Port X Depth for Optional
In-Port Valves****Extend Retract Extend Retract
Single Acting (S/A) Cylinders, actuated hydraulically 1 direction, spring returned.14-2718-00 Right
5,0000.56
1.10 2.50 N/A 1.184 N/A 1.295 SAE 4 X .7514-2718-01 Left 0.5614-2718-02 Straight 1.1014-2121-00 Right
7,5000.62
1.18 2.68 N/A 1.787 N/A 2.092 SAE 4 X .7514-2121-01 Left 0.6214-2121-02 Straight 1.18
Double Acting (D/A) Cylinders, actuated hydraulically both directions.14-2818-00 Right 0.56
1.18414-2818-01 Left 5,000 0.56 1.10 2.50 2.411 2.647 1.295 SAE 4 X .7514-2818-02 Straight 1.1014-2221-00 Right
7,5000.62
1.18 2.68 3.553 1.787 4.177 2.092 SAE 4 X .7514-2221-01 Left 0.6214-2221-02 Straight 1.18
Double Acting (D/A) Cylinders, Long Stroke, actuated hydraulically both directions.14-2818-03 Right
5,0001.25
1.79 2.50 2.411 1.184 4.327 2.12714-2818-04 Left 1.25 SAE 4 X .7514-2818-05 Straight 1.7914-2221-03 Right
7,5001.25
1.81 2.68 3.553 1.787 6.421 3.22714-2221-04 Left 1.25 SAE 4 X .7514-2221-05 Straight 1.81
Single And Double ActingnSingle Acting models have increased spring forces for positive return in higher backpressure applications. nManifold mounting capability as well as SAE porting.nOne piece body construction reduces potential leak paths and improves rigidity.nTungsten Carbide ball for strength and wear.n TuffCam™ Low Profile Clocking feature uses standard length Vektek arm.n Avoid cylinder damage and preserve warranty by using recommended flow rate limits and time calculations. nOptional In-Port Flow Control is a meter-in device with reverse free flow check valve. nOptional In-Port Sequence valve is a sequencing device with reverse free flow check valve.
DimensionsModelNo. A B D E F G H J K L M N P R T U V X Y Z AC AD AE AF
Single Acting (S/A) Cylinders, actuated hydraulically 1 direction, spring returned.14-2718-00
2.47 8.04 3.43 4.76 .98 .49 1.250 N/A .42 .57 .56 1.10 2.79 1.08 3.37 .52 1.39 1.08 1.38 .51 SAE 4 N/A N/A 3/8-2414-2718-0114-2718-0214-2121-00
3.11 8.85 3.79 5.14 .99 .51 1.500 N/A .53 .71 .62 1.18 3.50 1.38 3.94 .49 1.75 1.38 1.63 .51 SAE 4 N/A N/A 1/2-2014-2121-0114-2121-02Double Acting (D/A) (Both Standard and Long Stroke* Models) Cylinders, actuated hydraulically both directions.
14-2818-0X2.47
7.63*9.00
3.43*4.12
4.76*5.44
.98 .49 1.250M16 x 2.0 ↧ .75
.42 .57.56
*1.251.10*1.79
2.79 1.08 3.37 .52 1.39 1.08 1.38 .51 SAE 4 1.06 .50 3/8-2414-2818-0X14-2818-0X14-2221-0X
3.118.07*9.32
3.79*4.42
5.14*5.76
.99 .51 1.500M16 x 2.0 ↧ .75
.53 .71.62
*1.251.18*1.81
3.50 1.38 3.94 .49 1.75 1.38 1.63 .51 SAE 4 1.28 .50 1/2-2014-2221-0X14-2221-0X
ILS142020 REV E
SINGLE ACTING DOUBLE ACTING
C-21
TuffCam™ Swing Clamp
Low Profile Bottom Flange
![Page 22: TuffCam™ Swing Clamps - VektekWhat makes the cam follower ball seat so special in these units? The three cams and cam balls guide the rotation of the plunger providing greater support](https://reader034.vdocuments.us/reader034/viewer/2022042420/5f36ff427a75be74143d5e7e/html5/thumbnails/22.jpg)
www.vektek.com 800-992-0236 © Vektek, April 2019
* All ports (except breather), are shipped with removable steel plugs installed.** Counter bores for Ø7/16 diameter x 1/16 (2-011) O-Ring face seals provided.*** When used as manifold mounted, all four mounting bolts must be used to assure proper O-Ring face sealing. Recommended fastener sizes are listed in column AF.
For proper sealing, mating surface must be flat within 0.003 in. with a maximum 63 µ in.Ra surface finish.
Mounting DimensionsModel No. B C D E F
14-2718-XX14-2818-XX
3/8-24 DP 0.59 1.080 1.080 1.381 0.572
14-2121-XX14-2221-XX
1/2-20DP 0.78 1.380 1.380 1.630 0.713
DimensionsModelNo. A B D E F G H J K L M N P R T U V X Y Z AC AD AE AF
Single Acting (S/A) Cylinders, actuated hydraulically 1 direction, spring returned.14-2718-00
2.47 8.04 3.43 4.76 .98 .49 1.250 N/A .42 .57 .56 1.10 2.79 1.08 3.37 .52 1.39 1.08 1.38 .51 SAE 4 N/A N/A 3/8-2414-2718-0114-2718-0214-2121-00
3.11 8.85 3.79 5.14 .99 .51 1.500 N/A .53 .71 .62 1.18 3.50 1.38 3.94 .49 1.75 1.38 1.63 .51 SAE 4 N/A N/A 1/2-2014-2121-0114-2121-02Double Acting (D/A) (Both Standard and Long Stroke* Models) Cylinders, actuated hydraulically both directions.
14-2818-0X2.47
7.63*9.00
3.43*4.12
4.76*5.44
.98 .49 1.250M16 x 2.0 ↧ .75
.42 .57.56
*1.251.10*1.79
2.79 1.08 3.37 .52 1.39 1.08 1.38 .51 SAE 4 1.06 .50 3/8-2414-2818-0X14-2818-0X14-2221-0X
3.118.07*9.32
3.79*4.42
5.14*5.76
.99 .51 1.500M16 x 2.0 ↧ .75
.53 .71.62
*1.251.18*1.81
3.50 1.38 3.94 .49 1.75 1.38 1.63 .51 SAE 4 1.28 .50 1/2-2014-2221-0X14-2221-0X
X
R Y
L
BF
GPORTS
AED/A ONLY
H
A
REFERENCE ARMCROSSBOLT DIMENSION
3X .42CLOCKINGFEATURE
2X120
V
ADD/A
ONLY
T
P
Z
UE
M CLAMP STROKEN TOTAL STROKE
R
D
.23,SPANNER WRENCHHOLE .19
B
ILS142021 REV F
SWING CLAMP PLUNGER SHOWN IN THE EXTENDED STRAIGHT CAM POSITION.WRENCH FLAT (AD) ORIENTATION NOT CONTROLLED.
ORDER ARMSSEPARATELY
J THREADD/A ONLY
D/A PLUNGER END,SHOWN WITH STANDARD ARM4X K***
PORT
CLAMPMOUNT
MANIFOLD* & ** * & **
MANIFOLDMOUNTUNCLAMPPORT
3X .190 X 90ARM CLOCKING FEATURE
AC* CLAMPOR FLOWCONTROL PORTBREATHER PROVIDED
VENT-S/AUNCLAMP-D/A
AC* PORT
S/A PLUNGER END,SHOWN WITHSTANDARD ARM
C-22
TuffCam™ Swing Clamp
Low Profile Bottom Flange
![Page 23: TuffCam™ Swing Clamps - VektekWhat makes the cam follower ball seat so special in these units? The three cams and cam balls guide the rotation of the plunger providing greater support](https://reader034.vdocuments.us/reader034/viewer/2022042420/5f36ff427a75be74143d5e7e/html5/thumbnails/23.jpg)
© Vektek, July 2020 800-992-0236 www.vektek.com
Low Profile Rod Position Sensing Swing Clamps n Double Acting TuffCam™clamps available for use on both 5,000 lbs and 7,500 lbs clamps. n Actuator Rod Position System can be used with a mechanical switch or air logic system to detect when clamp is in position.n Actuator rod is concentric to plunger shaft.n Actuator rod moves with the same rotary and linear motion as the plunger.n All TuffCam™ features apply to these units.n TuffCam™ Clocking feature uses standard length Vektek arm.nOptional In-Port Flow Control is a meter-in device with reverse free flow check valve. nOptional In-Port Sequence valve is a sequencing device with reverse free flow check valve.
Low Profile Rod Position Sensing System
Model No.
Clamp Swing
Direction
Cylinder Capacity
(lbs)
A(in)
Port X Depth for Optional
In-Port Valves*
TuffCam Bottom Flange (D/A) clamps, hydraulic retract and extend
14-2818-00-PR Right5,000 1.82 SAE 4 X .7514-2818-01-PR Left
14-2818-02-PR Straight14-2221-00-PR Right
7,500 1.90 SAE 4 X .7514-2221-01-PR Left14-2221-02-PR Straight
TuffCam Top Flange (D/A) clamps, hydraulic retract and extend
14-0618-00-PR Right5,000 1.82 SAE 4 X .7514-0618-01-PR Left
14-0618-02-PR Straight14-0621-00-PR Right
7,500 1.90 SAE 4 X .7514-0621-01-PR Left14-0621-02-PR Straight
TuffCam Bottom Flange Long Stroke (D/A) clamps, hydraulicretract and extend
14-2818-03-PR Right5,000 2.51 SAE 4 X .7514-2818-04-PR Left
14-2818-05-PR Straight14-2221-03-PR Right
7,500 2.53 SAE 4 X .7514-2221-04-PR Left14-2221-05-PR Straight
TuffCam Top Flange Long Stroke (D/A) clamps, hydraulicretract and extend
14-0618-03-PR Right5,000 2.53 SAE 4 X .7514-0618-04-PR Left
14-0618-05-PR Straight14-0621-03-PR Right
7,500 2.53 SAE 4 X .7514-0621-04-PR Left14-0621-05-PR Straight
* In-Port Valves require the use of manifold mount ports.
ALENGTH
ROD FULLYEXTENDED
.40THREADLENGTH
1.132PILOT BOSS,
OPTIONAL
.05
.72LENGTH
ROD FULLYRETRACTED
.20 WRENCH FLAT
.17 WRENCH FLAT
.249
ILS140026 REV F
THREADM5 X 0.8
TuffCam™ Swing Clamp
Low Profile Rod Position Sensing
C-23
![Page 24: TuffCam™ Swing Clamps - VektekWhat makes the cam follower ball seat so special in these units? The three cams and cam balls guide the rotation of the plunger providing greater support](https://reader034.vdocuments.us/reader034/viewer/2022042420/5f36ff427a75be74143d5e7e/html5/thumbnails/24.jpg)
www.vektek.com 800-992-0236 © Vektek, April 2019
Magnetic Position Sensing Swing Clampsn TuffCam™ Low Profile Swing Clamps 5,000 lbs and 7,500 lbs models only. n Sensors sold separately. n Sensor mounting housing is concentric to plunger shaft.n For use with Double Acting clamps only. n TuffCam™ Clocking feature uses standard length Vektek arm.n Optional In-Port Flow Control is a meter-in device with reverse free flow check valve. n Optional In-Port Sequence valve is a sequencing device with reverse free flow check valve.
Sensor Kits Order Separately
62-2970-00 PNP Position Sensing Kit includes: a 29-7001-00 Sensor and a 27-6424-00 Cord set
62-2970-01 NPN Position Sensing Kit includes: a 29-7001-01 Sensor and a 27-6424-00 Cord set
The use of NPN or PNP is determined by the typeof control unit to which the sensor is connected. One Sensor is required for each sensing position.
Sensor Feature: - Normally Open Contact - LED Indicator Light - 10 to 30 VDC operating range - 3 Watt Maximum Contact Rating -≤0.8msSwitch-offtime -≤1.0msSwitch-ontime
Low Profile Magnetic Position Sensing System
Model No.
Clamp Swing
Direction
Cylinder Capacity
(lbs)
A(in.)
Port X Depth for Optional
In-Port Valves*TuffCam™ Bottom Flange (D/A)
Cylinders actuated hydraulically both directions14-2818-00-PS Right
5,000 2.58 SAE 4 X .7514-2818-01-PS Left14-2818-02-PS Straight14-2221-00-PS Right
7,500 2.58 SAE 4 X .7514-2221-01-PS Left14-2221-02-PS Straight
TuffCam™ Top Flange (D/A) Cylinders actuated hydraulically both directions
14-0618-00-PS Right5,000 2.58 SAE 4 X .7514-0618-01-PS Left
14-0618-02-PS Straight14-0621-00-PS Right
7,500 2.58 SAE 4 X .7514-0621-01-PS Left14-0621-02-PS Straight
TuffCam™ Bottom Flange Long Stroke (D/A) Cylinders actuated hydraulically both directions
14-2818-03-PS Right14-2818-04-PS Left 5,000 3.20 SAE 4 X .7514-2818-05-PS Straight14-2221-03-PS Right14-2221-04-PS Left 7,500 3.20 SAE 4 X .7514-2221-05-PS Straight
TuffCam™ Top Flange Long Stroke(D/A) Cylinders actuated hydraulically both directions
14-0618-03-PS Right5,000 3.20 SAE 4 X .7514-0618-04-PS Left
14-0618-05-PS Straight14-0621-03-PS Right
7,500 3.20 SAE 4 X .7514-0621-04-PS Left14-0621-05-PS Straight
* In-Port Valves require the use of manifold mount ports.
Approx. 196 in.Cordset
Approx. 15 in.Sensor
1.00
1.75.22 A
ILS140027 REV E
BN
BKBU
+
-
BNBKBU
+
-PNP
NPN143
143
Model No. 62-2970-00Schematic
Model No. 62-2970-01Schematic
increments)in 15is controllable
(radial orientationT-Slot for sensor
TuffCam™ Swing Clamp
Low Profile Magnetic Position Sensing