tubos mbt y su colocacion en la molares
TRANSCRIPT
victory series™ buccal tubesMBT™ System Prescription
3Unitek24
Upper 2nd Non-Convertible Single - Funneled
Torque Offset .018 in.L/R .022 in.
-19° 8° UL 3 067-873 1 3 067-973 1-19° 8° UR 3 067-872 2 3 067-972 2
Upper 1ST Convertible Double Combination - Occlusal Headgear
Torque Offset .018 in.L/R .022 in.
-14° 10° L .045 068-893 068-993-14° 10° R .045 068-894 068-994-14° 10° L .051 068-895 068-995-14° 10° R .051 068-896 068-996
Head Gear
Upper 1ST Convertible Single
Torque Offset .018 in.L/R .022 in.
-14° 10° L 3 068-897 1 3 068-997 1-14° 10° R 3 068-898 2 3 068-998 2
Upper 1ST Convertible Double Combination - Gingival Headgear
Torque Offset .018 in.L/R .022 in.Head Gear
-14° 10° L .045 068-885 068-985-14° 10° R .045 068-886 068-986-14° 10° L .051 068-887 068-987-14° 10° R .051 068-888 068-988
Upper 1ST Convertible Triple Combination - Occlusal Headgear
Torque Offset .018 in.L/R .022 in.Head Gear
-14° 10° L .045 068-889 068-989-14° 10° R .045 068-890 068-990-14° 10° L .051 068-891 068-991-14° 10° R .051 068-892 068-992
Bas
e
Bas
e
4 Buccal Tube is availablewith a bondable base.3213 Appliance is available in APC™ II Adhesive
Coated Appliance System.
Note
APC™ II Brackets sold in units of five. Measurements are in millimeters unless otherwise noted.
APC™ II Adhesive Coated Appliance System
Upper 2ND Non-Convertible Single - Distal Notch
Torque Offset .018 in.L/R .022 in.
-14° 10° L 3 067-857 1 3 067-957 1-14° 10° R 3 067-858 2 3 067-958 2
Upper 1ST Non-Convertible Single - Funneled
Torque Offset .018 in.L/R .022 in.
-14° 10° UL 3 067-879 1 3 067-979 1-14° 10° UR 3 067-878 2 3 067-978 2
victory series™ buccal tubesMBT™ System Prescription
USA and PR 800.423.4588Canada 800.443.1661
25
Lower 1ST Convertible Double
Torque Offset .018 in.L/R .022 in.
-20° 0° L 3 067-861 3 3 067-961 3-20° 0° R 3 067-860 4 3 067-960 4
Lower 1ST Convertible Single
Torque Offset .018 in.L/R .022 in.
-20° 0° L 3 067-819 3 3 067-919 3-20° 0° R 3 067-820 4 3 067-920 4
Lower 2ND Non-Convertible Single - Distal Notch
Torque Offset .018 in.L/R .022 in.
-10° 0° L 3 067-816 3 3 067-916 3-10° 0° R 3 067-815 4 3 067-915 4
Lower 1ST Non-Convertible Single - Funneled
Torque Offset .018 in.L/R .022 in.
-20° 0° LL 3 067-877 3 3 067-977 3-20° 0° LR 3 067-876 4 3 067-976 4
Lower 1ST Non-Convertible Single
Torque Offset .018 in.L/R .022 in.
-20° 0° L 3 067-867 3 3 067-967 3-20° 0° R 3 067-868 4 3 067-968 4
Bas
e
APC™ II Adhesive Coated Appliance System
Bas
e
Upper
Buccal Tubes for Partially Erupted Second Molars
Torque Offset .018 in.L/R .022 in.
-14° 0° L 3 066-407 1 3 066-507 1-14° 0° R 3 066-408 2 3 066-508 2
Lower
Torque Offset .018 in.L/R .022 in.
-10° 0° L 3 066-403 3 3 066-503 3-10° 0° R 3 066-404 4 3 066-504 4
Bas
e
Bas
e
APC™ II Adhesive Coated Appliance System
4 Buccal Tube is availablewith a bondable base.3213 Appliance is available in APC™ II Adhesive
Coated Appliance System.
Note
APC™ II Brackets sold in units of five. Measurements are in millimeters unless otherwise noted.
victory series™ 2nd bicuspid tubesMBT™ System Prescription
3Unitek26
Metal Injection Molded,including integral hook
No need for ligatures to keepwire in place
No tie-wings to comeinto occlusion
Ligature wire channel(patent pending)
Chamfered tubeopening to assist inwire insertion
Same in-out dimensionas Victory Series™ 2nd Bicuspid brackets
Micro-Etched base
There is less chance ofocclusal interferencefrom tubes
• Ligation Free – no added sliding friction
• No Tie-Wings – less chance for occlusal interference
• Chamfered Tube Opening to assist in wire insertion
• Micro-Etched Base
• Available in APC™ Adhesive Coated Appliance System
• Offset Base Option
Off
set
Bas
e
AP
C™
PL
US
AP
C™
II
3 5 058-801 0 Lower Left 2nd Bicuspid Tube .018 Slot (-17° torque, 2° angulation)
3 5 058-802 0 Lower Right 2nd Bicuspid Tube .018 Slot (-17° torque, 2° angulation)
3 5 058-803 0 Upper Left / Right 2nd Bicuspid Tube .018 Slot (-7° torque, 0° angulation)
3 5 058-901 0 Lower Left 2nd Bicuspid Tube .022 Slot (-17° torque, 2° angulation)
3 5 058-902 0 Lower Right 2nd Bicuspid Tube .022 Slot (-17° torque, 2° angulation)
3 5 058-903 0 Upper Left / Right 2nd Bicuspid Tube .022 Slot (-7° torque, 0° angulation)
Note
APC™ II and APC™ PLUS Brackets sold inunits of five.
Measurements are in millimeters unless otherwise noted.
3 Use this prefix to order APC™ II AdhesiveCoated Appliance System. 5 Use this prefix to order APC™ PLUS Adhesive Coated
Appliance System with color change adhesive.
Available in APC™ II AdhesiveCoated Appliance System
Available in APC™ PLUS AdhesiveCoated Appliance System
Adhesión de tubosen las molares
Adhesión de tubosen las molares
Técnica MBTLPPV
PRIMERA MOLAR INFERIOR• En el centro de la corona. El bordeEn el centro de la corona. El bordeoclusaloclusal del tubo debe ser paralelo aldel tubo debe ser paralelo alborde lingual de la banda.borde lingual de la banda.
•• El tubo bucal debe estar paralelo aEl tubo bucal debe estar paralelo ala líneala línea intercrestaintercresta. Altura: 2.5mm.. Altura: 2.5mm.
Trevisi Hugo. Smartclip Tratamento Ortodontico com sistema de Aparelho Autoligado. Rio de Janeiro : Elsevier, 2007.
Posicionamiento Axial
PosicionamientoHorizontal
Posicionamiento vertical
••Muchas vecesMuchas veces la posición della posición deltubo setubo se veve comprometidacomprometida porporlas sobremordidas o por lalas sobremordidas o por lafuerte inclinación Lingualfuerte inclinación Lingualdebido a la Curva de Wilson.debido a la Curva de Wilson.
Considerando lasConsiderando las bandas, es recomendablebandas, es recomendablesoldar los tubos bucales más para distal,soldar los tubos bucales más para distal,dándole paralelismo condándole paralelismo con el borde lingual deel borde lingual dela banda, cementándola de acuerdo con lala banda, cementándola de acuerdo con laanatomíaanatomía deldel diente.diente.
Considerando lasConsiderando las bandas, es recomendablebandas, es recomendablesoldar los tubos bucales más para distal,soldar los tubos bucales más para distal,dándole paralelismo condándole paralelismo con el borde lingual deel borde lingual dela banda, cementándola de acuerdo con lala banda, cementándola de acuerdo con laanatomíaanatomía deldel diente.diente.
Error del posicionamiento horizontaldel tubo bucal en el sentido mesial,propiciando la rotación del molar.
Trevisi Hugo. SmartclipTratamento Ortodontico com sistema de Aparelho Autoligado. Rio de Janeiro : Elsevier, 2007.
Así debe ser
SEGUNDA MOLAR INFERIOR•• En el centro de la corona , bordeEn el centro de la corona , borde oclusaloclusaldel tubo paralelo al borde lingual de ladel tubo paralelo al borde lingual de labanda.banda.
•• El tubo bucal debe estar paralelo a la líneaEl tubo bucal debe estar paralelo a la líneaintercrestaintercresta. Altura : 2.5 mm. Altura : 2.5 mm..
Trevisi Hugo. SmartclipTratamento Ortodontico com sistema de Aparelho Autoligado. Rio de Janeiro : Elsevier, 2007.
PRIMERA MOLAR SUPERIOR•• En el centro de la corona clínica a laEn el centro de la corona clínica a laaltura de 3 mm.altura de 3 mm.
•• El centro del tubo debe coincidir conEl centro del tubo debe coincidir conel surcoel surco vestibularvestibular..
•• BordeBorde oclusaloclusal del tubo paralelo a ladel tubo paralelo a lalínealínea vestibularvestibular intercrestaintercresta..
•• En el centro de la corona clínica a laEn el centro de la corona clínica a laaltura de 3 mm.altura de 3 mm.
•• El centro del tubo debe coincidir conEl centro del tubo debe coincidir conel surcoel surco vestibularvestibular..
•• BordeBorde oclusaloclusal del tubo paralelo a ladel tubo paralelo a lalínealínea vestibularvestibular intercrestaintercresta..
SEGUNDA MOLAR SUPERIOR•• En el centro de la coronaEn el centro de la coronaclínica a la altura de 2 mm.clínica a la altura de 2 mm.
•• El centro del tubo debeEl centro del tubo debecoincidir con el surcocoincidir con el surcovestibularvestibular..
•• BordeBorde oclusaloclusal del tubodel tuboparalelo a la líneaparalelo a la línea vestibularvestibularintercrestaintercresta..
•• En el centro de la coronaEn el centro de la coronaclínica a la altura de 2 mm.clínica a la altura de 2 mm.
•• El centro del tubo debeEl centro del tubo debecoincidir con el surcocoincidir con el surcovestibularvestibular..
•• BordeBorde oclusaloclusal del tubodel tuboparalelo a la líneaparalelo a la línea vestibularvestibularintercrestaintercresta..
Trevisi Hugo.SmartclipTratamento Ortodontico com sistema de Aparelho Autoligado. Rio de Janeiro : Elsevier, 2007.