Presentation on Texas Sampling
MD Flow Thru System
2
Manual Continuous
Sampling liquid into a Bottle or Container
3
SHROUDASSEMBLY
PROCESSNEEDLE
PROCESSNEEDLEPURGE
PROCESSFLOW THRU
VAPORVENT
VENTNEEDLE
SAMPLE
MODE
DESIGNED BY:
REV DATEDATE:
SCALE:
DRAWN BY:
CHECKED BY:
DRAWING NO.
JOB NO.REVISED CLIENT
TITLE
ACAD REF
MD: Sample Mode
4
MD: Patented Purge Mode
5
MD versus 3-way ball valve
MD has hardened ceramic seat (8x stronger than steel versus 3-way soft seat
MD has ½” (or larger) flow through porting versus ¼” for 3-way MD is proprietary sample valve technology versus 3-way ball
valve technology MD has TSI bolt pattern for easy addition of secondary ISO
valve or change to stinger tube MD has a multi-turn handle to allow control of flow into bottle
versus 3-way quarter turn handle MD has no internal volume allowing for a representative
sample versus 3-way with ball valve cavity. TSI can supply either the MD or the 3-way versus customer
preference but the MD is a durable robust valve designed for process sampling
6
Hardened Seat
Optional Purge
Flow Through
Easy Bolt Pattern for various orientations
Replaceable Needles
7
Vent Needle: Pencil Point
Pencil Point Design: reduces plugging of vent needle
PENCIL POINT VENT NEEDLEFOR MD, TSI3, MI, MBD
8
Patented PNP Rotameter indicates positive flow
Optional Carbon Canister
Procedure Tag
Stainless Steel Bottle Shroud
Drawing A1
9
10
Ssisisisisisisisis
SAMPLE IN1/2" TUBE
CONN
SAMPLE OUT1/2" TUBE
CONN
VENT1/4" TUBE
CONN
N2
SUPPLY1/4" TUBE
CONN
96
150
3NEEDLEPURGE
PRESSURE
PROCESS12
(361)575-8087TEXAS SAMPLING, INC.
TO STOP SAMPLETURN CW
PURGENEEDLE
TM
EXAS
NC.
AMPLING
1
0
4
3
2
6
5
TO OPEN SAMPLEVALVE TURN CCW
OPERATING7"
14"
INSTRUCTIONS
6-22-95
N.T.S.
KLM
TYP-026CMD - FLOW THRUSAMPLE SYSTEM
W/ PNP
5-17-99
1-23-01
5-7-96
2-26-97
4-7-97
6-22-98
4-8-99
8
9
3
4
5
6
7
UPDATE
CHG ROT PLT
UPDATE
PLT MOUNT VLV
UPDATE
ADD CONN.
CHG ROTAMETER
FOR FLOW SEE DRAWING TYP-026A
PAT. # - 5,431,067
MD Layout
Additional Features : A1
This drawing features the patented MD flow thru valve discussed above as well as the pencil point vent needle
This system is equipped with a bottle enclosure to further protect the operator
Process block valves are equipped on the inlet and outlet of the sample system
An optional cooler is shown for cooling the process prior to sampling.
11
Drawing E2
12
13
OPERATINGINSTRUCTIONS
1
0
4
3
2
6
5
DRAIN1/2" FNPT
DRAIN1/2" FNPT
4-6-00
N.T.S.
KLM
TYP-025KMD - FLOW THRUSAMPLE SYSTEM
W/ PNP
FOR FLOW SEE DRAWING TYP-025I
SAMPLE OUT1/2" TUBE
CONN
SAMPLE IN1/2" TUBE
CONN
7"
14"
N2
SUPPLY1/4" TUBE
CONN
PAT. # - 5,431,067
(512)575-8087TEXAS SAMPLING, INC.
MD with Stinger and Enclosure
Steam Stinger
1. Drawing E2 is equipped with a steam stinger so that the process is kept hot throughout the sampling process. The steam stinger will insure that the sample will not set up in the line in order to achieve a representative sample each time.
2. This system is also equipped with a bottle enclosure to protect the operator from any exposure to the sample.