ts1€¦ · all wood and timber construction that is part of this project shall comply ... all wood...

11
990 JOHN ADAMS PARKWAY P.O. BOX 2212 - IDAHO FALLS, IDAHO 83402-2212 (P) 208-522-8779 (F) 208-522-8785 (W) nbwarchitects.com ARCHITECTURE PLANNING INTERIORS architects p.a. nbw SCOTT L NIELSON, A.I.A. KEVIN R BODILY, A.I.A. JAMES H WYATT, A.I.A PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PROJECT: SHEET TITLE: RIGBY PIONEER CEMETERY RIGBY, IDAHO MAINTENANCE BUILDING FOR: TS1.1 15023 JAN 2018 SLN FLOOR PLAN AND ELEVATIONS CGK N

Upload: others

Post on 18-Jul-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: TS1€¦ · All wood and timber construction that is part of this project shall comply ... All wood connection hardware shown on plans is based upon Simpson Strong Tie products

990 J

OHN A

DAMS

PARK

WAY

P.O.

BOX 2

212 -

IDAH

O FAL

LS, I

DAHO

8340

2-22

12(P

) 208

-522

-877

9 (F)

208-

522-

8785

(W) n

bwarc

hitec

ts.co

m

AR

CH

IT

EC

TU

RE

PL

AN

NI

NG

IN

TE

RI

OR

S

archit

ects

p.a.

nbw

SC

OTT

L N

IELS

ON

, A.I.

A. K

EV

IN R

BO

DIL

Y, A

.I.A

. JA

ME

S H

WY

ATT

, A.I.

A

PROJECT NO.

DATE:

DRAWN BY:

CHECKED BY:

DRAWING NO.:

REVISIONS

PROJEC

T:

SHEE

T TI

TLE:

RIG

BY P

IONEER C

EM

ETERY

RIG

BY,

IDAHO

MAIN

TENANCE B

UIL

DIN

G F

OR:

TS1.1

15023

JAN 2018

SLN

FLO

OR P

LAN A

ND E

LEVATIO

NS

CGK

N

Page 2: TS1€¦ · All wood and timber construction that is part of this project shall comply ... All wood connection hardware shown on plans is based upon Simpson Strong Tie products

N

990 J

OHN A

DAMS

PARK

WAY

P.O.

BOX 2

212 -

IDAH

O FAL

LS, I

DAHO

8340

2-22

12(P

) 208

-522

-877

9 (F)

208-

522-

8785

(W) n

bwarc

hitec

ts.co

m

AR

CH

IT

EC

TU

RE

PL

AN

NI

NG

IN

TE

RI

OR

S

archit

ects

p.a.

nbw

SC

OTT

L N

IELS

ON

, A.I.

A. K

EV

IN R

BO

DIL

Y, A

.I.A

. JA

ME

S H

WY

ATT

, A.I.

A

PROJECT NO.

DATE:

DRAWN BY:

CHECKED BY:

DRAWING NO.:

REVISIONS

PROJEC

T:

SHEE

T TI

TLE:

RIG

BY P

IONEER C

EM

ETERY

RIG

BY,

IDAHO

MAIN

TENANCE B

UIL

DIN

G F

OR:

SD1.1

15023

JAN 2018

SLN

FLO

OR P

LAN A

ND E

LEVATIO

NS

CGK

Page 3: TS1€¦ · All wood and timber construction that is part of this project shall comply ... All wood connection hardware shown on plans is based upon Simpson Strong Tie products

N

N

990 J

OHN A

DAMS

PARK

WAY

P.O.

BOX 2

212 -

IDAH

O FAL

LS, I

DAHO

8340

2-22

12(P

) 208

-522

-877

9 (F)

208-

522-

8785

(W) n

bwarc

hitec

ts.co

m

AR

CH

IT

EC

TU

RE

PL

AN

NI

NG

IN

TE

RI

OR

S

archit

ects

p.a.

nbw

SC

OTT

L N

IELS

ON

, A.I.

A. K

EV

IN R

BO

DIL

Y, A

.I.A

. JA

ME

S H

WY

ATT

, A.I.

A

PROJECT NO.

DATE:

DRAWN BY:

CHECKED BY:

DRAWING NO.:

REVISIONS

PROJEC

T:

SHEE

T TI

TLE:

RIG

BY P

IONEER C

EM

ETERY

RIG

BY,

IDAHO

MAIN

TENANCE B

UIL

DIN

G F

OR:

A1.1

15023

JAN 2018

SLN

FLO

OR P

LAN A

ND E

LEVATIO

NS

JHB

Page 4: TS1€¦ · All wood and timber construction that is part of this project shall comply ... All wood connection hardware shown on plans is based upon Simpson Strong Tie products

990 J

OHN A

DAMS

PARK

WAY

P.O.

BOX 2

212 -

IDAH

O FAL

LS, I

DAHO

8340

2-22

12(P

) 208

-522

-877

9 (F)

208-

522-

8785

(W) n

bwarc

hitec

ts.co

m

AR

CH

IT

EC

TU

RE

PL

AN

NI

NG

IN

TE

RI

OR

S

archit

ects

p.a.

nbw

SC

OTT

L N

IELS

ON

, A.I.

A. K

EV

IN R

BO

DIL

Y, A

.I.A

. JA

ME

S H

WY

ATT

, A.I.

A

PROJECT NO.

DATE:

DRAWN BY:

CHECKED BY:

DRAWING NO.:

REVISIONS

PROJEC

T:

SHEE

T TI

TLE:

RIG

BY P

IONEER C

EM

ETERY

RIG

BY,

IDAHO

MAIN

TENANCE B

UIL

DIN

G F

OR:

A1.2

16062

JAN 2018

KRB

WALL

SECTIO

NS

CGK

Page 5: TS1€¦ · All wood and timber construction that is part of this project shall comply ... All wood connection hardware shown on plans is based upon Simpson Strong Tie products

I. GENERAL APPLICATION

II. CODES AND SPECIFICATIONS

III. DESIGN CRITERIA

IV. GENERAL STRUCTURAL NOTES

V. CONCRETE

VI. REINFORCING STEEL

VII. PRE-ENGINEERED WOOD TRUSSES

VIII. TIMBER

A. These drawings must be used in conjunction with the architectural drawings to clearly define therequirements for construction.

B. Do not scale drawings.

C. In the opinion of the Contractor, any items that appear to be deficiencies, omissions, contradictionsor ambiguities in the drawings, should be brought to the attention of the Architect and/or G&SStructural Engineers.

A. International Building Code (IBC) - 2015 Edition

A. Wind 3 Second Gust Wind Speed = 115 MPH Ultimate 90 MPH Nominal

Exposure = BRisk Category II; Iw = 1.00Enclosure Classification-EnclosedComponents and Cladding Pressure = 15 psf

B. Seismic Ss =45.3%g SDS = 0.434gS1 = 15.6%g SD1 = 0.226gRisk Category II IE = 1.00Site Class = D Seismic Design Category = DR = 6.5 V = Cs W = 0.067WLight Frame Bearing Walls with Shear Panel SystemEquivalent Lateral Force Analysis Method

C. Live Loads per IBC Sec. 1607 Uniform (psf) Concentrated (lbs.)1. Ground snow 50 -----2. Roof a) Snow Load (Is, Ce, Ct = 1.0) 35 ----- b) Live Load 20 (Non-concurrent with snow load)

D. Dead Loads Uniform (psf)1. Framing system 15 (Roof)

E. Design Assumptions1. Soil bearing pressure assumed to be 1500 psf for columns and wall footings as per IBC

Table 1806.2 based upon a clay, sandy clay, silty clay, clayey silt, silt and sandy silt (CL, ML, MH and CH) type soil. Any variations encountered, different from the soil typeassumed, shall be brought to the attention of G&S Structural Engineers beforeproceeding.

F. Allowable Stresses (unless otherwise noted)1. Concrete f'c (@ 28 days) a) Footing and foundation walls 3000 psi b) Slabs on grade 3000 psi unexposed slabs

4000 psi exposed to freeze/thaw. Provide5%-7% air entrainment for exposed slabs

2. Reinforcing steel ASTM A615 Grade 603. Wood framing a) Stud walls No. 2 Douglas Fir b) 2x joists No. 2 Douglas Fir

A. All footings shall bear on undisturbed soil or rock. The foundation shall bear on the same soil typethroughout the entire structure. A minimum distance of 3'-0" shall be maintained from finished gradeto the bottom of all concrete footings.

B. Caution shall be taken not to undermine adjacent existing footings. See Allowable Trenching andUtility Placement Detail 1/S1.1.

C. Contractor shall verify all dimensions in the field: any variation from the drawings shall be brought tothe attention of the Architect. Any proposed field changes shall have prior approval from theArchitect.

D. Adequate shoring and bracing of all structural members during construction shall be provided.

E. Backfill under slabs and footings shall be with approved material. Place fill in 8" maximum loose liftsand compact to 95% maximum dry density in accordance with ASTM D1557.

A. Special inspection is not required based upon IBC Section 1705.3 (design f’c = 2500 psi).

B. Concrete shall be of ready mix type conforming to ASTM C94.

C. When the average daily temperature is expected to drop below 40º F for 3 or more successivedays, the concrete shall comply with the Cold Weather Concreting Standard (ACI 306). Place noconcrete against frozen earth.

D. All vertical reinforcement in piers and walls shall be doweled from the footing or structure belowwith rebar of the same size and spacing as required above. All footing dowels shall have at least 40diameters embedment into concrete above and shall have a 6” hook in footing below.

E. Provide corner bars at all intersecting corners. Use same bar size and spacing as horizontal wallreinforcement. Where horizontal reinforcing bars join concrete columns the reinforcing shall runcontinuous through columns. Where continuous horizontal reinforcement terminates, use a 90° returnor separate corner bar.

F. Splices of reinforcement at points of maximum stress shall be avoided. All longitudinalreinforcement in beams and lintels shall be continuous without splices between supports. Minimumoverlap for lapped splices shall be as follows:

#4 - 24"

G. Reinforce all concrete walls as shown on the Concrete Wall Schedule.

H. All exterior vertical concrete surfaces below finished grade, where in contact with earth, shall beprotected with an asphaltic coating.

I. No aluminum products shall be embedded in the concrete.

J. All construction joints shall be located so as not to impair the strength of the structure. Unlessnoted on the drawings, all reinforcement shall be continuous through the joints. Each constructionjoint shall be keyed.

K. Construction joints in large areas of slab on grade shall be placed in long strip construction fashionin widths not to exceed 12 feet. Control joints at 12 feet maximum shall be saw-cut transverse tothe length. See Concrete Slab on Grade Details Sheet S1.2.

A. Welding or tack welding of reinforcing bars to other bars, plates, angles, etc. is prohibited unlessASTM A706 (weldable) rebar is utilized.

B. All detailing, fabrication and placing of reinforcing bars shall conform to the ACI Manual of StandardPractice for Detailing Reinforcing Concrete Structures (ACI 315).

C. Reinforcement shall be accurately placed as indicated on the drawings and adequately supported toprevent displacement before concrete or masonry grout is placed.

D. The following minimum concrete cover for reinforcement shall be provided, unless otherwisenoted.

Cast against and permanently exposed to earth....................... 3"Exposed to earth or weather - #5 and smaller................ 1-1/2"Not exposed to earth or weather - slabs, walls......................... 3/4"

A. See architectural drawings for roof slopes and/or truss configurations. Review structural drawingsfor intended truss placement and support locations.

B. Individual trusses and truss spacing to be designed by the Truss Manufacturer. The truss spacingsshown on the plans are maximum spacings; the Truss Manufacturer may combine and/or space trussescloser together as required by the individual truss design.

C. The pre-engineered roof truss members shall be designed to support the following loads in additionto the dead load of the member as applicable.1. 35 psf roof snow load plus drifting as indicated on plans.2. 20 psf roof live load.3. 8 psf dead load top chord.4. 7 psf dead load bottom chord.5. Applicable wind and seismic loads.6. A 10 psf bottom chord live load nonconcurrent with any other live loads.7. Applicable mechanical, electrical and sprinkler loads

D. The shop drawings and design calculations shall be produced by, or under the supervision of aregistered Professional Engineer. The shop drawing submittal to the Contractor shall include thefollowing:1. Truss placement plan.2. Truss design drawing for each truss, stamped and signed by a registered Professional Engineer licensed in the state in which the project will be constructed.3. Connection requirements for truss to truss girder, truss ply to ply and field splices shall be designed by Truss Manufacturer and submitted with shop drawings. Contractor shall provide such connection requirements as specified in shop submittals.

E. Contractor shall provide all permanent bracing requirements for the structure, including the trussesas indicated in structural drawings and shop drawings. The lateral bracing shall be anchored to solidend walls or permanent diagonal bracing.

F. No truss shall be modified without the Truss Manufacturer's approval.

A. All wood and timber construction that is part of this project shall comply with the TimberConstruction Manual of the AITC. Other members with equivalent size and strength can besubstituted only if documentation is provided to substantiate capacity of new product. All woodframing members shall have a moisture content less than 19% unless otherwise noted.

B. Notching of any structural member other than that shown on the drawings is prohibited.

C. There shall be at least two nails at each contact point, with 8d thru 1" material, 16d thru 2" materialand 40-60d thru 3" material.

D. Wherever possible nails should be driven perpendicular to the grain instead of toe nailed.

E. All wood materials in direct contact with concrete or masonry or within 6" of soil shall be pressuretreated wood or wood of natural resistance to decay.

F. Where wood tends to split, holes for nails shall be bored a diameter smaller than that of the nails.

G. Roof and floor sheathing face grain must be perpendicular to its supports.

H. All wall studs shall be continuous from floor to roof diaphragms.

I. Roof and wall diaphragm sheathing nails or other approved sheathing connections shall bedriven so that their head or crown is flush with the surface of the sheathing.

J. All wood connection hardware shown on plans is based upon Simpson Strong Tie products. Equivalenthardware may be used upon approval of the Architect. All hangers are to match the width and depthof framing members with correct slope and skew where applicable. Fill all nail holes unless otherwisenoted. All Simpson connectors in exterior applications or in contact with pressure treated woodshall have a corrosion resistant coating. The coating type shall be determined by referencing thefollowing Simpson Strong-Tie tables: “Coatings Available” and “Environment/Treatment ClassificationChart”. (www.strongtie.com/info)

K. For Alternate Staple Schedule for roof and wall sheathing, see Sheet S1.1.

NAILING SCHEDULE

All nails in this schedule may be sinker, box or pneumatic driven nails unless otherwise specified. All fastenersexposed to weather or moisture and/or fasteners less than ½" Ф driven into pressure treated lumber shall bestainless steel or galvanized. Other nails with proper revised spacing may be used with written approval of theArchitect.

CONNECTION FASTENING

LVL built-up beams & headers See Wood Header Schedule

2x Joists and 2x trusses 3-8d toenail @ each bearing2-8d endnail from rim to joist or truss

Blocking between 2x joists and 2x trusses 3-8d toenail to support plate, joist or truss

Bottom (sole) plate to joist or blocking 2-16d @ each joist16d @ 6" o.c. @ rim joist

Studs to bottom (sole) plate 2-16d endnails or 4-8d toenails

Blocking between studs 2-8d toenail each end or2-16d endnails each end

Double Top PlatesLower plate to top of stud 2-16dUpper plate to lower plate-staggered 16d @ 16" o.c.Upper plate to lower plate @ intersection 3-16dUpper plate to lower plate @ splice point 16d @ 4" o.c. staggered(Minimum lap: 4'-0" staggered splices)

Built-up corner studs 16d @ 16" o.c. staggered

STRUCTURAL DRAWING NOTES

PIONEER CEMETERY MAINTENANCE BUILDING

SW2

1SW

MARK

2/S1.2

2/S1.22x YES

2x YES

ONE SIDE @ 4" O.C. @ 12" O.C.

ONE SIDE @ 6" O.C. @ 12" O.C.

EDGES INTERMED.

WALLSTUDS

(1)

SILL PLATE/BOTTOMPLATE (2)

ANCHORBOLTS

(3)

3x3x.229 PLATEWASHERS (4)

WALLBLOCKING

(5)

TOP PLATEDETAIL (6)

(7) 7/16" APARATED

SHEATHING

NAILING (0.131"Ø x2 1/2" MIN.)

2x6 @16" O.C.

2x6 @16" O.C.

1. USE NO. 2 DOUGLAS FIR.

2. USE PRESSURE TREATED WOOD WHEN IN CONTACT WITH CONCRETE.

3. USE A307 STEEL. DO NOT RECESS NUT AND WASHER INTO SILL PLATE. MINIMUM 2 ANCHOR BOLTS PER PIECE. LOCATE

ANCHOR BOLTS 10" FROM EACH END OF PIECE. CONTRACTOR MAY USE SIMPSON TITEN HD ANCHORS OF THE SAME

DIAMETER AND SPACING SPECIFIED. PROVIDE A MINIMUM EMBEDMENT OF 3 3/4" FOR 5/8"Ø TITEN HD ANCHORS.4. USE A36 STEEL. DO NOT RECESS INTO SILL PLATE. IF PLATE WASHERS ARE NOT REQUIRED, USE STANDARD WASHERS.

5. AT BEARING WALLS (BW) ONLY, BLOCKING MAY BE ELIMINATED IF WALL SHEATHING IS APPLIED.

6. WHERE TOP PLATE IS CUT OR DISCONTINUOUS, STRAP ACROSS BREAK WITH SIMPSON MST37 STRAP.

7. SHEATHING TO BE PLYWOOD OR OSB. (VERTICAL OR HORIZONTAL ORIENTATION.) PROVIDE BLOCKING AT ALL

UNSUPPORTED PANEL EDGES FOR NAILING, INCLUDING PANEL EDGES ABOVE AND BELOW OPENINGS.

8. NAILS SHALL BE STAGGERED AT PANEL JOINTS AND SILL PLATE EDGES.

9. INTERMEDIATE WALL STUDS MAY BE 2x6 AT CONTRACTORS OPTION, BUT NOT AT PANEL JOINTS.

10. PANEL JOINTS SHALL BE OFFSET TO FALL ON DIFFERENT FRAMING MEMBERS.

5/8"Ø @4'-0" O.C.7" EMBED

5/8"Ø @4'-0" O.C.7" EMBED

2x6 @PANEL JT.

2x6 @PANEL JT.

WOOD WALL SCHEDULE

MARK REMARKS

HOLDOWN SCHEDULE

NOTE:ALL HOLDOWNS ARE BASED UPON SIMPSON STRONG-TIE CONNECTORS. FASTEN HOLDOWN AS SPECIFIED BY MANUFACTURER.

MODELNUMBER

HOLDOWN TYPE

ANCHORBOLT

DIAMETER

MINIMUMEMBEDMENTIN CONCRETE

MINIMUMCOLUMN

SIZE

HD1 STHD10 A - 10" 2- 2x

WOOD COLUMN

SHEAR WALL EDGENAILING FULL HEIGHTOF HOLDOWN COLUMN

SIMPSON STRAPTIE SEESCHEDULE

FASTEN PERMANUFACTURER

PRESSURE TREATEDSILL PLATE

WOOD DIAPHRAGM

WOOD HEADER

WD

WH

S1.1

S1.2

HOLDOWN ANCHOR

SHEAR WALLSW

HD

CONCRETE WALL

CONCRETE SLAB

CW

CS

S1.1

S1.1

S1.2

S1.2

LEGEND

CONCRETE FOOTING

DESCRIPTION

CF S1.2 -

DETAIL

-

-

-

-

-

-

MARK ONSHEET

SCHEDULEON SHEET

CONSTRUCTION JOINTCCJ - S1.2

BLOCKED DIAPHRAGM UNBLOCKED DIAPHRAGM

TYPICAL HORIZONTAL DIAPHRAGM NAILING

SPAN RATING

WD1

MARK

WOOD FRAMING

SHEATHING PANELS

40/20

SHEATHING

NONE SUPPORTED EDGESBOUNDARY

INTERMEDIATE @ 12" O.C.@ 6" O.C.@ 6" O.C.

WOOD DIAPHRAGM SCHEDULE

BOUNDARY NAILING @SHEAR WALLS ANDBUILDING EDGES

NO BLOCKING @PANEL JOINT

EDGE NAILING@ SUPPORTEDPANEL EDGE

INTERMEDIATE NAILING@ SUPPORTS

2x4 FLAT BLOCKINGBETWEEN FRAMINGMEMBERS @ SHEATHINGPANEL EDGES (TYP.)

PANEL JOINTBLOCKING

(1) NAILING (0.131"Øx2 1/2"MIN. U.O.N.)

19/32" C-DAPA RATEDSHEATHING

CONC.

9" MIN.

1'-6" MIN.

6"

MIN

.

6"

MIN

.

4" MIN.

FILL TO BESAME WIDTH

AS FTG.

NO EXCAVATIONBELOW THIS LINE

PERPENDICULAR TO FOUNDATION

TRENCH

6

PARALLEL TO FOUNDATION

12

SEE NOTES FORREINF. AROUNDOPENING

FOOTINGNO PIPETHRU FTG.

CONC. FILL TOBE IN PLACEBEFORE FTG. ISPOURED

IF PIPE OR DUCT INTERFERESWITH FOOTING AND PIPE ORDUCT CANNOT BE DROPPED,CONTACT ENGINEER.

BACKFILL

PIPE ORDUCT

NONE

@ 2" O.C.

@ 2" O.C.

@ 3" O.C.

@ 4" O.C.

@ 6" O.C.

NONE

@ 3" O.C.

@ 3" O.C.

@ 4" O.C.

14 GAUGE

NONE

@ 2" O.C.

@ 3" O.C.

@ 2" O.C.

@ 4" O.C.

NONE

16 GAUGE15 GAUGE

@ 12" O.C. @ 8" O.C. @ 6" O.C.@ 8" O.C.

ALTERNATE STAPLE SCHEDULEFOR APA RATED SHEATHING

0.131"Øx2 1/2" NAILSPACING AS

SPECIFIED IN THEWOOD WALL OR

DIAPHRAGMSCHEDULES

NOTE:

1. ALL STAPLES TO HAVE 7/16" MIN. CROWN WIDTH AND MUST BE

INSTALLED WITH THEIR CROWNS PARALLEL TO THE LONG

DIMENSION OF THE FRAMING MEMBERS.

2. MINIMUM PENETRATION FOR ALL STAPLE GAUGES IS 1 1/2".

3. FASTENER SPACING @ 2" O.C. OR LESS REQUIRES NOMINAL 3x

MEMBER.

DESIGNER:DRAFTER:

505 LINDSAY BOULEVARDIDAHO FALLS, IDAHO 83402

PHONE: (208) 523−6918 / FAX: (208) 523−6922

PROJECT NUMBER:

&STRUCTURALENGINEERSSG

E−MAIL: [email protected] COPYRIGHT 2017

CHECKER:

990

JOHN

ADA

MS P

ARKW

AY

P.O.

BOX

221

2 - I

DAHO

FALL

S, ID

AHO

8340

2-22

12

(P) 2

08-5

22-8

779

(F) 2

08-5

22-8

785

(W) n

bwar

chite

cts.

com

SC

OT

T L

NIE

LS

ON

, A

.I.A

. K

EV

IN R

BO

DIL

Y, A

.I.A

. JA

ME

S H

WY

AT

T, A

.I.A

PROJECT NO.

DATE:

DRAWN BY:

CHECKED BY:

DRAWING NO.:

REVISIONS

PROJECT:

SHEET T

ITLE:

arch

itect

sA R

C H I

T E

C T

U R

EP

L A N N I

N G

I N

T

E R

I O R

S

nbw

p.a.

LJT DCG MDA17200

S1.1

15023

RIGBY PIONEER CEM

ETERY

RIGBY, IDAHO

GENERAL NOTES, SCHEDULES &

COM

MON DETAILS

JANUARY 2018

MAINTENANCE BUILDING FOR:

3/4" = 1'-0"

HOLDDOWN TYPE A

S1.1

1ALLOWABLE TRENCHING &UTILITY PLACEMENT DETAIL

CONSTRUCTION SET JAN 2018

Page 6: TS1€¦ · All wood and timber construction that is part of this project shall comply ... All wood connection hardware shown on plans is based upon Simpson Strong Tie products

SL

AB

TH

ICK

NE

SS

2nd. POUR

EQ

.

TH

.TH

.

EQ

.

SL

AB

TH

ICK

NE

SS

1st. POUR

3/4" MIN.

TH

.TH

.

WITHIN 24 HOURSAFTER POUR

TOOLED JOINT OR1/4" MAX. SAW CUT

CONCRETE SLAB ON GRADE DETAILS

TH/4

1 1/2"

COMPACTED GRANULAR FILL

TYPICAL CONTROL JOINT (CCJ)

CONCRETE SLAB SCHEDULE

TH

/4 (

MIN

IMU

M)

CS1 6"

THICKNESSMARKSLAB

TYPICAL CONSTRUCTION JOINT (CCJ)

#5 @ 24" O.C. #5 @ 24" O.C.

REMARKS

ON PLAN DENOTES TOP OF SLAB (U.O.N.)

REINFORCEMENT

LONGITUDINAL TRANSVERSE(TH)

FOR ≥ TH 6" USE1/2"Øx16" DOWEL @ 12" O.C.W/ 8" SLEEVE @ SECONDPOUR. PAINT JOINT W/ BONDBREAKER PRIOR TO SECONDPOUR

UNDISTURBED ORCOMPACTED SOIL

REINFORCEMENT(SEE SCHED.)

H/3

H/3

H/3

MIN.

dd/3

L

L/3 L/3

16"

d/31" MAX.

d/6

d/4

d

2"

MIN

.

2"

MIN

.

d

d/3

MA

X.

1 1/2" MIN.

BEARING TYP.

d/4

5/8"MIN.

d/3 MAX.

L/3

H

d

d/3

d/6

d/3

NO NOTCHINGALLOWED

AL

LO

WE

D N

O H

OL

ES

OR

NO

TC

HE

S

NOTCHING OF DOUBLE TOP PLATE

SIZE SCHEDULE

NOTCHING OF ROOF OR FLOOR JOIST

HOLE BORING OF ROOF OR FLOOR JOIST

2x12

2x10

2x8

2x6

2x4

MEMBER

DBL. TOP PLATE

2 3/43 5/8

2 1/43

2 3/8 1 3/4

1 3/81 3/4

7/8

d/4d/3

1 1/8

1 7/8

1 1/2

1 1/8

7/8

5/8

d/6

WOOD STUD

NOTCHING & HOLEBORING OF EXT.OR BEARING WALLSTUDS

HOLES & NOTCHES IN BEAMS ARENOT ALLOWED UNLESS OTHERWISEAPPROVED IN WRITING BYENGINEER

2-SIMPSON CS16STEEL STRAPS (MIN.)

4'-0" MIN. LAP

FLOOR OR ROOF LINE

JOIST SPACE

16d NAILS @ 4" O.C.STAGGERED

DOUBLE TOP PLATECHORD MEMBER

REMARKS

DBL. 2x KING STUD

HEADER SIZE

3- 2x8

MARK

WH1

WH2

WOOD HEADER

SEE ARCH. DWGS.ROUGH OPENING

2x CRIPPLE STUD

RO

UG

H O

PE

NIN

G

16d NAILS @ 12"

2x KING STUD

10d NAILS @ 3"

WOOD HEADER SCHEDULE

MATERIAL

2.0E LVL 2- 2x6

CRIPPLESTUD

1- 2x6

3- 1 3/4x11 7/8ATTACH LVL'S TOGETHER W/ 2 ROWS OF 16d

NAILS DRIVEN FROM ONE SIDE

NO. 2DOUG. FIR

@ OPENING GREATERTHAN 6'-0"

EQ. EQ.

WIDTHWIDTH

WIDTH

6"

MARK

CW1

ON PLAN DENOTES TOP OF WALL (U.O.N.)

REMARKS

CONCRETE WALL SCHEDULE

PLACEMENT TYPE

TYPE A

REINFORCEMENT

VERTICAL

#4 @ 18" O.C.

HORIZONTAL

#4 @ 16" O.C.

TYPE

A

VERT.REINF.

HORIZ.REINF.

6"CW2 #5 @ 18" O.C.#5 @ 18" O.C.A

2- #4 CONT.

LONGITUDINAL

CONCRETE FOOTING SCHEDULE

CF1

MARK

CONT.10" 1'-4"

LENGTHDEPTH WIDTH

-

TRANSVERSE

REINFORCEMENT

ON PLAN DENOTES TOP OF FOOTING (U.O.N.)

4- #4 CONT.CF2 CONT.10" 3'-0" #4 @ 24" O.C.

3"

(SE

E S

CH

ED

ULE

)T

IE S

PA

CIN

G3

"3

"

1 1/2"CLR.

2"

L

TYPE A

CONCRETE

ELEVATION OF CONCRETE PIER

12"x12"CP1

W

VERTICAL REINF.

REINFORCED FOOTING

#3 @ 10"A 4- #5

MATERIALMARKREINFORCEMENT

TIES

PIER SCHEDULE

TYPEVERTICAL

REMARKS

HORIZONTAL WALLREINF.CONTINUOUS THRU PIERWHERE APPLICABLE.

ANCHOR BOLTS OR CAST IN STEEL PLATEASSEMBLY. SEE PLAN & SECTION FORCONNECTION @ TOP.

SIZE(W x L)

PIER TYPES

ON PLAN DENOTES TOP OF SLAB (U.O.N.)

DESIGNER:DRAFTER:

505 LINDSAY BOULEVARDIDAHO FALLS, IDAHO 83402

PHONE: (208) 523−6918 / FAX: (208) 523−6922

PROJECT NUMBER:

&STRUCTURALENGINEERSSG

E−MAIL: [email protected] COPYRIGHT 2017

CHECKER:

990

JOHN

ADA

MS P

ARKW

AY

P.O.

BOX

221

2 - I

DAHO

FALL

S, ID

AHO

8340

2-22

12

(P) 2

08-5

22-8

779

(F) 2

08-5

22-8

785

(W) n

bwar

chite

cts.

com

SC

OT

T L

NIE

LS

ON

, A

.I.A

. K

EV

IN R

BO

DIL

Y, A

.I.A

. JA

ME

S H

WY

AT

T, A

.I.A

PROJECT NO.

DATE:

DRAWN BY:

CHECKED BY:

DRAWING NO.:

REVISIONS

PROJECT:

SHEET T

ITLE:

arch

itect

sA R

C H I

T E

C T

U R

EP

L A N N I

N G

I N

T

E R

I O R

S

nbw

p.a.

LJT DCG MDA17200

S1.2

15023

RIGBY PIONEER CEM

ETERY

RIGBY, IDAHO

SCHEDULES &

COM

MON DETAILS

JANUARY 2018

MAINTENANCE BUILDING FOR:

S1.2

1ALLOWABLE PENETRATION INLIGHT FRAMED 2x LUMBER

S1.2

2LAP SPLICE OF DBL TOP PLATE

CONSTRUCTION SET JAN 2018

Page 7: TS1€¦ · All wood and timber construction that is part of this project shall comply ... All wood connection hardware shown on plans is based upon Simpson Strong Tie products

96'-6"CF1

96'-6"CF1

96'-6"CF1

100'-0"CF1

96'-6"CF1

CW1

CW1

CW1

CW1

100'-0"CS1100'-0"CS1

100'-6"

100'-6"

100'-6"

100'-6"

1S2.1

______________________________________________

1S2.1

______________________________________________

1S2.1

______________________________________________

1S2.1

______________________________________________ 1S2.1

______________________________________________

2S2.1

______________________________________________

2S2.1

______________________________________________

2S2.1

______________________________________________

2S2.1

______________________________________________

3S2.1

______________________________________________

DOWEL INTOEXISTINGSEE NOTE #3

DOWEL INTOEXISTINGSEE NOTE #3

@ HIGH POINTS

CONTRACTOR'S NOTE:PROVIDE CONTROL JOINTS @ 10'-0" O.C.

96'-6"CF1

CW1 99'-0"

99'-0"

99'-0"

96'-6"CF1

CW1

96'-6"CF1

CW1

WH1 WH1

WH2

WH2

WH1WH1 WH1

WH1

WH1 WH2 WH1

WH1WH1WH1

SW1

SW1

SW1

SW1

SW1

SW 2

SW1

HD1

HD

1

HD1

HD1

HD1

HD1

HD1

HD1

HD1 H

D1

HD1

HD1

SW 2

SW 2

SW1

TY

P.

EX

TE

RIO

RW

AL

LS

U.N

.O.

PR

E-E

NG

INE

ER

ED

WO

OD

TR

US

S

WD1TYP.

@ 2

'-0

" O

.C. S

EE

NO

TE

#2

4S2.1

______________________________________________

4S2.1

______________________________________________

6S2.1

______________________________________________

6S2.1

______________________________________________

5S2.1

______________________________________________

DRAG TRUSSSEE SECTION 5/S2.1

3"

CL

R.

TREATED SILL PLATEPRESSURE

WALL SHEATHING

GRADE

CONCRETE WALL

ANCHOR BOLT

6" REINFORCED

ALTERNATE HOOK

FOOTINGREINFORCED

DIRECTION

WOOD STUD WALL

CONCRETE SLAB

1/2" PREMOLDEDJOINT FILLER

ON GRADE

3"

CL

R.

CONCRETE WALL6" REINFORCED

FOOTINGREINFORCED

CONCRETEAPRON

DIRECTIONALTERNATE HOOK

#4x CONT.

@ OPENING

CONCRETE SLAB

ON GRADE

@ 24" O.C.#4x

2'-0"

2'-0

"6

"

6"

@ 2'-0" O.C.

2x6 BLOCKING

DBL. TOP PLATE

WALL SHEATHING

GABLE END TRUSS

EDGE BOARD

ROOF SHEATHING

BOUNDARY NAILING

WOOD STUD WALL

PRE-ENGINEERED

2x6 DIAGONAL @ 4'-0" O.C.

WOOD TRUSS

@ EA. CONTACT POINT2x4 W/ 2- 16d NAILS

1

1

4- 16d NAILS

2x6 BLOCKING @ DIAGONAL

2x BLOCKING@ DIAGONAL

4- 16d NAILS

EDGE BOARD

WALL SHEATHING

BOUNDARY NAILING

ROOF SHEATHING

BLOCKING @EVERY OTHER BAY

DBL. TOP PLATE

WOOD STUD WALL

SIMPSON H2.5A

PRE-ENGINEEREDWOOD TRUSS

DBL. TOP PLATE

WALL SHEATHING

ROOF SHEATHING

BOUNDARY NAILING

WOOD STUD WALL

PRE-ENGINEERED

TRUSS TO BE DESIGNED

SIMPSON A35 @ 2'-0" O.C.

TO TRANSFER 225 PLF

LATERAL FORCE

TREATED SILL PLATEPRESSURE

WALL SHEATHING

ANCHOR BOLT

FOOTINGREINFORCED

WOOD STUD WALL

CONCRETE SLABON GRADE

FTG. WIDTH

DE

PT

H

FT

G.

CL

R.

3"

CCJ

GENERAL NOTES:

1. For marked description items on Plan see legend on sheet S1.

2. See Architectural Drawings for dimensions and roof slopes notshown.

3. All horizontal rebar in walls and footings to be drilled andepoxied into existing foundation. Use Simpson AT anchoringsystem w/ 4 1/4" minimum embedment or equivalent.

CW2

CW2

CW2

CW2

97'-0"CF2

97'-0"CF2

97'-0"CF2

97'-0"CF2

106'-0"

106'-0"

106'-0"

106'-0"

97'-0"CF2

CW2 99'-0"

1S2.1

______________________________________________

CP1

106'-0

"

TYP. @ 6

LOCATIO

NS

7S2.1

______________________________________________TYP.

7S2.1

______________________________________________SIM.

CONCRETE SLABTO MATCH APRONOR SEE ARCH.

3"

CL

R.

GRADE

6" REINFORCEDCONCRETE WALL

ALTERNATE HOOK

FOOTINGREINFORCED

DIRECTION

CONCRETE SLAB

1/2" PREMOLDEDJOINT FILLER

ON GRADE

LA

P S

PL

ICE

2'-0

"

DESIGNER:DRAFTER:

505 LINDSAY BOULEVARDIDAHO FALLS, IDAHO 83402

PHONE: (208) 523−6918 / FAX: (208) 523−6922

PROJECT NUMBER:

&STRUCTURALENGINEERSSG

E−MAIL: [email protected] COPYRIGHT 2017

CHECKER:

990

JOHN

ADA

MS P

ARKW

AY

P.O.

BOX

221

2 - I

DAHO

FALL

S, ID

AHO

8340

2-22

12

(P) 2

08-5

22-8

779

(F) 2

08-5

22-8

785

(W) n

bwar

chite

cts.

com

SC

OT

T L

NIE

LS

ON

, A

.I.A

. K

EV

IN R

BO

DIL

Y, A

.I.A

. JA

ME

S H

WY

AT

T, A

.I.A

PROJECT NO.

DATE:

DRAWN BY:

CHECKED BY:

DRAWING NO.:

REVISIONS

PROJECT:

SHEET T

ITLE:

arch

itect

sA R

C H I

T E

C T

U R

EP

L A N N I

N G

I N

T

E R

I O R

S

nbw

p.a.

LJT DCG MDA17200

S2.1

15023

RIGBY PIONEER CEM

ETERY

RIGBY, IDAHO

PLANS, SECTIONS &

DETAILS

JANUARY 2018

MAINTENANCE BUILDING FOR:

N 1/8" = 1'-0"

FOUNDATION PLAN

N 1/8" = 1'-0"

WALL FRAMING PLAN

N 1/8" = 1'-0"

ROOF PLAN

3/4" = 1'-0" S2.1

SECTION 2 3/4" = 1'-0" S2.1

SECTION 1

3/4" = 1'-0" S2.1

SECTION 6

3/4" = 1'-0" S2.1

SECTION 4

3/4" = 1'-0" S2.1

SECTION 5

3/4" = 1'-0" S2.1

SECTION 3

CONSTRUCTION SET JAN 2018

N 1/8" = 1'-0"

ENCLOSURE PLAN

3/4" = 1'-0" S2.1

SECTION 7

Page 8: TS1€¦ · All wood and timber construction that is part of this project shall comply ... All wood connection hardware shown on plans is based upon Simpson Strong Tie products

PROJECT NO,

DATE:

DRAWN BY:

PROJECT:

REVISIONS

SHEET T

ITLE

:

CHECKED BY:

DRAWING NO.:

15023

JAN. 2017

D SUDWEEKS

T DAVIS

990

JOHN

ADA

MS P

ARKW

AY

P.O.

BOX

221

2 - I

DAHO

FAL

LS, I

DAHO

834

02-2

212

(P) 2

08-5

22-8

779

(F) 2

08-5

22-8

785

(W) n

b-ar

chite

cts.

com

SC

OTT

L N

IELS

ON

, A.I.

A.

KE

VIN

R B

OD

ILY

, A.I.

A.

JAM

ES

H W

YA

TT, A

.I.A

.

AR

CH

IT

EC

TU

RE

PL

AN

NI

NG

IN

TE

RI

OR

S

nbw

archit

ects

p.a.

RIG

BY P

IONEER C

EM

ETARY

RIG

BY,

IDAHO

MAIN

TENANCE B

UIL

DIN

G F

OR:

EngineeredSystems

Associates

MECH &

PLB

G F

LOOR P

LAN

Page 9: TS1€¦ · All wood and timber construction that is part of this project shall comply ... All wood connection hardware shown on plans is based upon Simpson Strong Tie products

PROJECT NO,

DATE:

DRAWN BY:

PROJECT:

REVISIONS

SHEET T

ITLE

:

CHECKED BY:

DRAWING NO.:

15023

JAN. 2017

D SUDWEEKS

T DAVIS

990

JOHN

ADA

MS P

ARKW

AY

P.O.

BOX

221

2 - I

DAHO

FAL

LS, I

DAHO

834

02-2

212

(P) 2

08-5

22-8

779

(F) 2

08-5

22-8

785

(W) n

b-ar

chite

cts.

com

SCO

TT L

NIE

LSO

N, A

.I.A.

KEV

IN R

BO

DILY

, A.I.

A. J

AMES

H W

YATT

, A.I.

A.

AR

CH

IT

EC

TU

RE

PL

AN

NI

NG

IN

TE

RI

OR

S

nbw

archite

cts p.a

.RIG

BY P

IONEER C

EM

ETARY

RIG

BY,

IDAHO

MAIN

TENANCE B

UIL

DIN

G F

OR:

EngineeredSystems

Associates

SCHEDULE

S A

ND D

ETAIL

Page 10: TS1€¦ · All wood and timber construction that is part of this project shall comply ... All wood connection hardware shown on plans is based upon Simpson Strong Tie products

F

990 J

OHN A

DAMS

PARK

WAY

P.O.

BOX 2

212 -

IDAH

O FAL

LS, I

DAHO

8340

2-22

12(P

) 208

-522

-877

9 (F)

208-

522-

8785

(W) n

b-arc

hitec

ts.co

m

E1.0

DUPLEX RECEPTACLE

WALL MOUNTED FIXTURE

CEILING MOUNTED FIXTURE

FLUORESCENT FIXTURE

BRANCH CIRCUIT - HOME-RUN TO PANEL

BRANCH CIRCUIT - IN FLOOR OR UNDERGROUND

MECHANICAL EQUIPMENT OR DETAIL SYMBOL

DRAWING NOTE (ON THE SHEET WHERE SHOWN)

THERMOSTAT W/ 3/4"CONDUIT W/PULL CORD TO MECH. UNIT

FAN MOTOR CONNECTION POINT

BRANCH CIRCUIT - CONCEALED

* SEE MECHANICAL DRAWINGS FOR CONDUIT DESTINATION AND

M.C.

V.I.F.

A.F.F.

B.F.G.

NL

E.C.

ABOVE FINISHED FLOOR

BELOW FINISHED GRADE

VERIFY IN FIELD

NIGHT LIGHT (CONNECT TO UNSWITCHED LEG OF LTG CIRCUIT)

MECHANICAL CONTRACTOR

ELECTRICAL CONTRACTOR

MOTOR CONNECTION POINT

T

EF

TELEPHONE / DATA BOARD (GRND AS PER UTIL. CO)

TIME CLOCK SWITCHT

1

1

A-1,3

DOUBLE DUPLEX OUTLET (4-PLEX)

JUNCTION BOX

BRANCH PANELBOARD

J

EMERGENCY WALL LIGHT WITH 90MIN. BATTERY

PHOTOELECTRIC CELL/SWITCH

HVAC SYSTEM SENSOR - SEE MECHANICAL

E

S

WALL BOX DIMMER SWITCH. (SWITCH TO BE COMPAT. W/LOAD SERVED)

SINGLE POLE SWITCH (SEE SUBSCRIPTS)

RECESSED CAN FIXTURE

TRAC LIGHT SYSTEM

*

*

PUSHBUTTON (AS INDICATED ON DRAWINGS)

ROUGH-IN BOX MUD RING ORIENTATION.

F=FUSED DISCONNECT (FUSE PER EQUIP. NAMEPLATE)

DISCONNECT SWITCH (SIZE AND TYPE AS INDICATED)

B=ENCLOSED CIRCUIT BREAKER

CEILING MOUNTED DUPLEX RECEPTACLE

G.C. GENERAL CONTRACTOR

N.T.S.

NOT TO SCALE

V=VFD (PROVIDED BY M.C. CONNECTED AND INSTALLED BY E.C.)

S

SCALE:

SITE PLAN - ELECTRICAL

1" = 20' - 0"

SCALE:

FLOOR PLAN - MECH. CONNECTIONS

1/8" = 1' - 0"

Page 11: TS1€¦ · All wood and timber construction that is part of this project shall comply ... All wood connection hardware shown on plans is based upon Simpson Strong Tie products

F

S

M

M

M

990 J

OHN A

DAMS

PARK

WAY

P.O.

BOX 2

212 -

IDAH

O FAL

LS, I

DAHO

8340

2-22

12(P

) 208

-522

-877

9 (F)

208-

522-

8785

(W) n

b-arc

hitec

ts.co

m

E2.0

SCALE:

FLOOR PLAN - LIGHTING

1/8" = 1' - 0"

SCALE:

FLOOR PLAN - POWER

1/8" = 1' - 0"

B

MAIN BRKR. AMPS

LOAD/POLE

MAIN LUGS ONLY

19

FEEDER CONDUCTOR SIZE:

TOTAL LOAD/PHASE

REMARKS:

AMPS

WATTS

41

29

37

39

35

33

31

27

25

21

23

CLASS

LOCATION

MAKE/MODEL

LOAD NAME

AAMPWATTSNO.

9

17

15

11

13

7

5

1

3

E

BRKCIR

LOAD

MAIN SW.

O

P

L

20

S.C. INT CAP/BKR.

40

CONDUIT SIZE

42

30

38

36

34

32

28

26

24

22

AMPS.

NO.WATTS

E

CAMP

10

18

16

14

12

8

6

2

4

FEED BOTTOM

FEED TOP

DIMENSIONS

BRK

AMPS

L

O

P

LOAD

CIR

SURFACE

FLUSH

LOAD NAME