TROTEC ® GmbH & Co. KG • Grebbener Straße 7 • D-52525 Heinsberg Tel.: +49 2452 962-400 • Fax: +49 2452 962-200 www.trotec.com • E-Mail: [email protected] TRT-BA-TTK 31 E-TC-001-EN Operating Manual – Dehumidifier TTK 31 E TTK 31 E EN

Upload: esanu-viorel

Post on 24-Dec-2015

239 views

Category:

Documents


0 download

DESCRIPTION

Manual dezumidificator Tk31

TRANSCRIPT

Page 1: Trt Ba Ttk 31 e Tc 001 En

TROTEC® GmbH & Co. KG • Grebbener Straße 7 • D-52525 HeinsbergTel.: +49 2452 962-400 • Fax: +49 2452 962-200www.trotec.com • E-Mail: [email protected]

T-B

A-T

TK 3

1 E-

TC-0

01-E

N

Operating Manual – Dehumidifier TTK 31 E

TTK 31 EEN

Page 2: Trt Ba Ttk 31 e Tc 001 En

EN Operating Manual – Dehumidifier TTK 31 E 1

Notes regarding the operating manual .................. 01Information about the device ................................ 02Safety................................................................... 04Transport.............................................................. 05Operation ............................................................. 05Errors and faults ................................................... 10Maintenance......................................................... 11Disposal ............................................................... 15Declaration of conformity...................................... 15

SymbolsHazardous electric current!Warns about hazards from electric cur-rent which can lead to injuries or evendeath.

Danger!Warns of a hazard which can lead to per-sonal injury.

Caution!Warns of a hazard which can lead todamage to property.

The current version of the operating manual can befound at: www.trotec.de

Legal noticeThis release replaces all previous releases. No part ofthis publication may be reproduced without writtenpermission. The same applies for electronicallyprocessing, duplicating or spreading the publication.Subject to technical changes. All rights reserved.Trademarks are used without guarantee that they maybe used freely and primarily following the spelling ofthe manufacturer. The product names used are regis-tered and should be treated appropriately. The deliv-ered product may vary from product images. Thisdocument was produced with all due care. We acceptno liability whatsoever for mistakes or omissions.© TROTEC®

Table of contents

Notes regarding the operating manual

Page 3: Trt Ba Ttk 31 e Tc 001 En

2 Operating Manual – Dehumidifier TTK 31 E EN

Description of the deviceThis device uses the principle of condensation to auto-matically dehumidify rooms.The fan sucks damp room air through the air inlet (7),the air filter (8), the evaporator and to the condenserlocated behind it. The air is cooled at the cold evapo-rator until it is below the dew point. Water vapour con-tained in the room air precipitates on the evaporatorfins as either condensation or frost. The dehumidified,cooled air is rewarmed at the condenser and blownout at a temperature of approx. 5 °C above room tem-perature. The drier air which is prepared in this waymixes with the air in the room. The humidity in theroom where the device is positioned is reduced as airconstantly circulates through the device. Dependingon the air temperature and the relative humidity, thecondensed water either drops continuously or onlyduring the defrost phase into the condensation trayand through the integrated drain nozzle into the con-densation tank (3) below. This is fitted with a float tomeasure the fill level. The device has a controlpanel (1) for operating and controlling the functions.Once the maximum fill level of the condensationtank (3) is reached, the condensation tank indicatorlight (see chapter "Operating elements") on the con-trol panel (1) flashes. The device switches off. Thecondensation tank indicator light only goes out againonce the emptied condensation tank (3) is reinserted.The condensed water can be diverted by attaching ahose at the condensation plug (6). The device can re-duce the relative humidity of a room by up to approx.49 %. It provides additional assistance for drying wetwashing or clothing in living or working spaces. Because of the heat radiation which is tied up in oper-ation, the room temperature can rise by approx. 1- 4 °C.

Device depictionInformation about the device

No. Operating element

1 control panel2 carry handle3 condensation tank4 feet5 air outlet6 condensation plug7 air inlet incl. air filter8 air filter

2

3

15

7

8

4

6

Page 4: Trt Ba Ttk 31 e Tc 001 En

EN Operating Manual – Dehumidifier TTK 31 E 3

Technical data

Circuit diagram

Parameters Values

Model TTK 31 EDehumidifying capacity, max. 12 l / 24 hOperating temperature 5-35 °CWorking range for relative humidity 49-100 %Volume of airflow, max. 120 m³/hElectric connection 230 V / 50 HzPower consumption, max. 240 WFuse (home) 10 ACondensation tank 1.6 lRefrigerant R134aAmount of refrigerant 100 gWeight 9 kgDimensions (HxDxW) 320 x 160 x 500 mmMinimum distance from walls of other objects A: Above: 45 cm

B: Behind: 45 cmC: Side: 45 cmD: Front: 45 cm

Sound pressure level LpA (1 m; complies with DIN 45635-01-KL3) 45 dB(A)

Page 5: Trt Ba Ttk 31 e Tc 001 En

4 Operating Manual – Dehumidifier TTK 31 E EN

Read this manual carefully before starting orusing the device. Store the manual near the deviceor its site of use!

• Do not use the device in potentially explosiverooms.

• Do not use the device in atmospheres containingoil, sulphur, chlorine or salt.

• Set the device in an upright and stable position.

• Do not expose the device to directly squirting wa-ter.

• Ensure that the air inlet and outlet are not obstruc-ted.

• Ensure that the side of the device where the air in-let is found is kept free of dirt and loose objects.

• Never insert objects into the device.

• Do not cover or transport the device during opera-tion.

• Ensure that all electric cables outside of the deviceare protected from damage (e.g. from animals).

• Only use extensions to the electric cable which areappropriate to the device power consumption, thelength of its cable and its use. Avoid electricaloverload.

• Only transport the device in an upright positionwith an emptied condensation tank.

• Dispose of the collected condensation. Do notdrink it. There is a risk of infection!

The device is not suitable for drying rooms and areasafter water damages from burst pipes or flooding.

Intended useUse the device TTK 31 E only for drying and dehumidi-fying room air, while adhering to and following thetechnical data.

Intended use encapsulates: • drying and dehumidifying:

– living rooms, bedrooms, bathrooms or base-ments

– laundries, holiday homes, camper vans, boats

• maintaining the dryness of:

– store rooms, archives, laboratories

– bathrooms, wash rooms and changing rooms

Improper useDo not place the device on damp or flooded ground.Do not use the device outdoors. Do not lay any ob-jects, e.g. wet clothing, on the device for drying. Anyunauthorised changes, modifications or alterations tothe device are forbidden.

Personnel qualificationsPeople who use this device must:

• be aware of the dangers that occur when workingwith electric devices in damp areas.

• take measures to protect themselves from directcontact with live parts.

• have read and understood the operating manual,especially the "Safety" chapter.

Maintenance tasks which require the housing tobe opened must only be carried out by specialistcompanies for cooling and air-conditioning or byTROTEC®.

Residual risksHazardous electric current!Work on the electrical components mustonly be carried out by an authorised spe-cialist company!

Hazardous electric current!Before any work on the device, removethe mains plug from the mains socket!

Safety

Page 6: Trt Ba Ttk 31 e Tc 001 En

EN Operating Manual – Dehumidifier TTK 31 E 5

Caution!To avoid damages to the device, neveroperate the device without an air filter in-serted!

Danger!Dangers can occur at the device when itis used by untrained people in an unpro-fessional or improper way! Observe thepersonnel qualifications!

Behaviour in the event of an emergency1. Disconnect the device from the mains power in an

emergency.

2. Do not reconnect a defective device to the mainspower.

To make the device easier to transport, it is fitted withlateral carry handles.Before transporting the device, proceed as follows:

1. Switch off the device at the mains switch (seechapter "Operating elements").

2. Remove the mains plug from the mains socket.Do not use the power cable to drag the device!

3. Empty the condensation tank. Check for drippingcondensation.

After transporting the device, proceed as follows:1. Set the device in an upright position after trans-

port.

2. Wait one hour before switching the device on!

StorageWhen out of use, store the device as follows:

• dry,

• with a roof overhead,

• in an upright position where it is protected fromdust and direct sunlight,

• with a plastic cover to protect it from invasive dust,if necessary.

• The storage temperature is the same as the rangegiven for the operating temperature in the chapter"Technical data".

• After being switched on, the device operates fullyautomatically until either a pre-set timer or thefloat indicating that the condensation tank is fulltakes care that the device switches itself off.

• So that the built in sensor can correctly detect thehumidity, the fan continues to operate until the de-vice is switched off.

• Avoid open doors and windows.

PositioningWhen positioning the device, observe the minimumdistance from walls of other objects as described inchapter "Technical data".

• Set the device in a level and stable position.

• If possible, set the device in the middle of a roomand keep it away from sources of heat.

Transport

Operation

CC

A

B

D

Page 7: Trt Ba Ttk 31 e Tc 001 En

6 Operating Manual – Dehumidifier TTK 31 E EN

• When positioning the device in wet areas such aslaundries, bath rooms or the like, secure the de-vice locally with an RCD (Residual Current protec-tive Device) which complies with the appropriateregulations.

• Ensure that extension cords are completely un-rolled.

Notes regarding the dehumidifying capacityThe dehumidifying capacity depends on:

• the spatial composition of the room

• the room temperature

• the relative humidity

The higher the room temperature and relative humidi-ty, the higher the dehumidifying capacity.For using in living rooms, a relative humidity of ap-prox. 50-60 % is sufficient. In store rooms and ar-chives, the humidity should not exceed approx. 50 %.

Operating elements

No. Operating element

9 Indicator light "FAN":lights up when the ventilation mode is activated (no dehu-midification of room air).

10 Indicator light "LOW": lights up with a low active ventilation speed. Additionally, the room air dehumidification is activated.

Indicator light "HIGH":lights up with a high active ventilation speed. Additionally, the room air dehumidification is activated.

11 Setting the desired humidity.

"Arrow up" key:Raises the desired humidity value (by max. 80 %).

"Arrow down" key:Decreases the desired humidity value (by min. 30 %).

Note!To start continuous operation mode, press the "Arrow down" or "Arrow up" key until "CO" is shown on the display (18).

12 Mains switch:Switches the device on or off (stand-by).

13 Operation indicator light:Lights up when the device is switched on.

14 Condensation tank full indicator light:Lights up once the maximum fill level of the condensation tank is reached or when the condensation tank is not installed correctly in the device.

15 Indicator light "DEFROST":Lights when the automatic defrost is active.

16 Indicator light "TIMER":Lights up when the "TIMER" function is active.

17 "TIMER" key:Sets the device operating time.

18 Display to show the desired level of humidity19 "MODE" key to select the operation mode "FAN", "LOW",

"HIGH", "AUTO".20 Indicator light "AUTO":

Lights up when automatic dehumidification is active.

% RH / hr

13

14

1211

15161719

109

1820

Page 8: Trt Ba Ttk 31 e Tc 001 En

EN Operating Manual – Dehumidifier TTK 31 E 7

Start procedureInsert air filter

Switch device on1. Ensure that the condensation tank is empty and

inserted correctly. Otherwise, the device will notoperate!

2. Insert the mains plug into a properly securedmains power socket.

3. Open the flap at the air outlet (5).

4. Switch on the device at the mains switch (12).

5. Check whether the condensation tank indicatorlight (14) is out.

6. Check whether the operation indicator light (13)lights up.

7. Regulate the room humidity level by using the"Arrow up" or "Arrow down" (11) keys.

8. Select the desired operation mode by pressingthe "MODE" key (19).

A.

C.

B.

Page 9: Trt Ba Ttk 31 e Tc 001 En

8 Operating Manual – Dehumidifier TTK 31 E EN

"Continuous" operation modeIn continuous operation mode, the device dehumidi-fies the air constantly, regardless of the humidity inthe air. To start continuous operation mode, press the "Arrowdown" or "Arrow up" key (11) until "CO" is shown onthe display (18). The continuous indicator light (16)lights up green.Additionally, an increased or decreased ventilationspeed can be set using the "MODE" key (19).

Adjusting the operating time/ starting time1. Press the "TIMER" key (17) with the device being

switched on to set the operating time of the de-vice. Press the "Arrow up" or "Arrow down"key (11) until the desired hour value is shown onthe display (18). The "TIMER" indicator light (16)is lit up. After the operating time has passed, thedevice automatically switches off.

2. To switch this function off, press the "TIMER"key (17) again until the "TIMER" indicator light isturned off.

Automatic defrostIf the room temperature is below 12 °C, the evapora-tor becomes covered in frost during dehumidification.This is why the device carries out an automatic defrostonce an hour. The "DEFROST" indicator light (15) is litup.

Emptying the condensation tank

A.

C.

B.

D.

TANK FULL

Page 10: Trt Ba Ttk 31 e Tc 001 En

EN Operating Manual – Dehumidifier TTK 31 E 9

Operation with hose attached to the condensation plug

Shut down procedure1. Switch off the device at the mains switch (see

chapter "Operating elements").

2. Do not touch the mains plug with wet or damphands.

3. Remove the mains plug from the mains socket.

4. Empty the condensation tank and wipe it dry witha clean cloth. Check for dripping condensation.

5. Clean the device, and especially the air filter, ac-cording to chapter "Maintenance".

6. Store the device according to chapter "Storage".

A.

B.

1/2″

Page 11: Trt Ba Ttk 31 e Tc 001 En

10 Operating Manual – Dehumidifier TTK 31 E EN

The accurate functionality of the device was testedduring production a number of times. However, iffunctionality faults do occur, then check the deviceaccording to the following list.

The device does not start:• Check the mains power

(230 V/1~/50 Hz).

• Check the mains plug for damages.

• Have the electrics checked by a specialist compa-ny for cooling and air-conditioning or by TROTEC®.

The device runs but forms no condensation:• Check the condensation tank is positioned correct-

ly. Check the fill level of the condensation tank andempty it if necessary. The condensation tank indi-cator light must not light up.

• Check the float in the condensation tank for dam-ages. If necessary, clean the float and condensa-tion tank. The float must be able to move freely.

• Check the room temperature. The working rangeof the device is between 5 °C and 35 °C.

• Ensure that the relative humidity complies with thetechnical data.

• Check that the selected humidity is realistic. Thehumidity in the room must be above the selectedrange. Reduce the selected desired humidity bypressing the "Arrow down" key (11), if necessary.

• Check the air filter is not dirty. If necessary, cleanor replace the air filter.

• From the outside, check the condenser for dirt (seechapter "Maintenance"). If your condenser is dirty,have it cleaned by a specialist company for coolingand air-conditioning or by TROTEC®.

The device is loud or vibrates; condensation leaks:• Check whether the device is standing upright and

on an even surface.

The device gets very warm, is loud or is losingperformance:

• Check the air inlets and air filter are not dirty. Re-move external dirt.

• Check the inside of the device and especially thefan, the fan housing, the evaporator and the con-denser for external dirt (see chapter "Mainte-nance"). If the inside of the device is dirty, have itcleaned by a specialist company for cooling andair-conditioning or by TROTEC®.

Does your device still not operate correctly afterthese checks?Bring the device to a specialist company for coolingand air-conditioning or to TROTEC® for repairs.

Errors and faults

Page 12: Trt Ba Ttk 31 e Tc 001 En

EN Operating Manual – Dehumidifier TTK 31 E 11

Maintenance intervals

Maintenance and care logDevice type: ........................................ Device number: ........................................

Maintenance

Maintenance and care interval before every start

when necessary

at least every 2 weeks

at least every 4 weeks

at least every 6 months

at least annually

empty condensation tank Xcheck air inlets and outlets for dirt and foreign objects and clean if necessary X

clean housing X Xvisually check whether the inside of the device is dirty X X

check air inlet grid and air filter for dirt and for-eign objects and clean or replace if necessary X X

replace air filter Xcheck for damages Xcheck attachment screws X Xcarry out a test run X

Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

check air inlets and outlets for dirt and foreign objects and clean if necessaryclean housingvisually check whether the inside of the device is dirtycheck air inlet grid and air filter for dirt and foreign objects and clean or replace if neces-saryreplace air filtercheck for damagescheck attachment screwscarry out a test runRemarks:

1. Date: ..................................Signature:...............................

2. Date: ..................................Signature:...............................

3. Date: ..................................Signature:...............................

4. Date: ..................................Signature:...............................

5. Date: ..................................Signature:...............................

6. Date: ..................................Signature:...............................

7. Date: ..................................Signature:...............................

8. Date: ..................................Signature:...............................

9. Date: ..................................Signature:...............................

10. Date: ................................Signature:...............................

11. Date: ................................Signature:...............................

12. Date: ................................Signature:...............................

13. Date: ................................Signature:...............................

14. Date: ................................Signature:...............................

15. Date: ................................Signature:...............................

16. Date: ................................Signature:...............................

Page 13: Trt Ba Ttk 31 e Tc 001 En

12 Operating Manual – Dehumidifier TTK 31 E EN

Activities for before the start of maintenance1. Do not touch the mains plug with wet or damp

hands.

2. Before any work, detach the mains plug!

3. Do not remove the float from the condensationtank.

Maintenance tasks which require thehousing to be opened must only becarried out by specialist companies forcooling and air-conditioning or byTROTEC®.

Visual check for dirt in the inside of the device1. Remove the air filter (see chapter "Cleaning the

air inlets and the air filter").

2. Shine a torch through the opening of the device.

3. Check the inside of the device for dirt.

4. If you see a thick layer of dust, have the inside ofthe device cleaned by a specialist company forcooling and air-conditioning or by TROTEC®.

5. Put the air filter back in.

Cleaning the housing and condensation tank1. Use a soft, lint-free cloth for cleaning.

2. Dampen the cloth with clean water. Do not usesprays, solvents, alcohol-based or abrasivecleaners to dampen the cloth.

Page 14: Trt Ba Ttk 31 e Tc 001 En

EN Operating Manual – Dehumidifier TTK 31 E 13

Cleaning the air inlets and the air filter

Caution!Ensure that the air filter is not worn ordamaged. The corners and edges mustnot be rounded or misshaped.Before reinserting the air filter, ensurethat it is dry and is not damaged!Read the chapter "Maintenance inter-vals" and replace the air filter punctually!

A.

B.

C.

D.

E.

Page 15: Trt Ba Ttk 31 e Tc 001 En

14 Operating Manual – Dehumidifier TTK 31 E EN

Overview and list of spare parts

No. Spare part No. Spare part No. Spare part

1 Filter 19 Pressing line plate 37 Fan blower3 Air inlet grille 20 Power cord 40 Condenser connector4 Back cover 21 Compressor 41 Strainer5 Evaporator 23 Rubber foot 42 Evaporator connector6 Humidity sensor 27 Chassis 43 Working tube8 Upper cover 28 Main body 44 Capillary9 Control panel sticker 29 Condenser 45 Discharge tube10 Wind deflector 30 Front cover 46 Condenser outlet tube11 Air outlet net 31 Left cover 47 Evaporator inlet tube14 Motor capacity 32 Water tank15 Main board 33 Floater16 Micro switch 34 Right cover17 Float connecting rod 35 Display board18 Compressor capacity 36 Motor

Note!The position numbers of the spare parts differ from those describing thepositions of other parts mentioned in this operating manual.

Page 16: Trt Ba Ttk 31 e Tc 001 En

EN Operating Manual – Dehumidifier TTK 31 E 15

In the European Union, electronic equip-ment must not be treated as domesticwaste, but must be disposed of profes-sionally in accordance with Directive

2002/96/EC of the European Parliament and Councilof 27th January 2003 concerning old electrical andelectronic equipment. At the end of its life, please dis-pose of this instrument in a manner appropriate to therelevant legal requirements.

The device uses an environmentally friendly andozone-neutral cooling agent (see chapter "Technicaldata"). Dispose of the refrigerant/oil mixture appropri-ately and according to the national regulations.

in accordance with the EC Low Voltage Directive2006/95/EC, Annex III, Section B and the EC Directive2004/108/EC about electromagnetic compatibility.Herewith, we declare that the dehumidifier TTK 31 Ewas developed, constructed and produced in compli-ance with the named EC directives.Applied harmonised standards:IEC 60335-1:2001/A2:2006IEC 60335-2-40:2002/A1:2005IEC 62233:2005

The marking is found on the device nameplate.

Manufacturer: Trotec GmbH & Co. KG Phone: +49 2452 962-400Grebbener Straße 7 Fax: +49 2452 962-200D-52525 Heinsberg E-mail: [email protected]

Heinsberg, 09/07/2013

Managing Director: Detlef von der Lieck

Disposal Declaration of conformity

Page 17: Trt Ba Ttk 31 e Tc 001 En

TROTEC® GmbH & Co. KG • Grebbener Straße 7 • D-52525 Heinsberg

Tel.: +49 2452 962-400 • Fax: +49 2452 962-200

www.trotec.com • E-Mail: [email protected]