trotec
TRANSCRIPT
Professional solutions for zone measurements, prelocation and pinpoint detection
Water loss reduction Measuring data documentation
EXCLUSIVEat Trotec !
FFT high performancecorrelator
Wireless sound logging system
Pressure datalogger
Trace gassensors
Pulse wavegenerator
Combi leak detector
Professional solutions for zone measurements, prelocation and pinpoint detection
Water loss reduction Measuring data documentation
Measuring technological innovations for leak detection in drinking water systems
Measuring technological innovations for leak detection in drinking water systems
TRT-
KAT-
LEDE
-WM
-06-
EN
EXCLUSIVEat Trotec !
BENEFITS IN PRACTICE:
Acoustic and trace gas leak detectionin only one device
High-resolution colour graphic displaywith touchscreen functions
The only one of its kind in itsclass. State-of-the-art smart function for even faster pinpoint leakdetection (patent filed)
Numerous preprogrammed commonapplications for quick access
All filters and parameters can be configured individually
Pipe detection mode
Complies with all guidelines govern -ing according to VBG 121 (when usedwith original headphones) (VBG - tradeassociation safety regulations)
Highly-sensitive, high-quality, robust precision microphone made in Germany
The innovative, state-of-the-art LD6000 combi detector is suitable for a variety of different application and allows you to detect leaks using both the acoustic and trace gas method with only a single device.
G Acoustic pinpoint leak detection with geophone h Detection and pipe laying, also for plastic pipes j acoustic body sound measurement. k trace gas leak detection in drinking water systems. l leak detection and leak tightness inspection of pipe systems in houses and industrial pipe networks.
LD6000 combi-detectorLeak detection and acoustic pipe location
Whether you need it for laying out pipesor to narrow down the search or pinpointa leak – the highly-sophisticated LD6000and the high-quality microphone, whichboth carry the hallmarks of a product made in Germany, allow you to determineeven the tiniest of leaks and display thesignal before it is processed.
Overview of the functionsF&L mode – hear and see leaksAs many as ten measuring cycles are dis-played either as a number or a two-seg-ment colour bar – one for frequency andone for volume. The leak is there wherethe two segments are at their steepest.
Smart modeThe state-of-the-art smart functionis the only one of its kind in itsclass and has been filed for patent– the smarter way to find leaks. Complex algorithmic calculations whichare carried out unseen in the heart ofthe device provide you with a clearview of what you need to see: the exactposition of the leak, revealed to you bymeans of a bar indicator which risessharply where the leak is. It doesn’t getany easier than that !
Long-term measurementsIn order to beable to pinpointthe leak exact -ly, an onboardsound logger can be activated to logmeasurements carried out over a periodof up to 60 minutes, which can thenbe used to determine or rule out anyleaks with the help of the recordedmeasurement curve.
Pipe detection modeThis mode is designed especially to de-tectplastic pipes which are subjectedto ultrasound via the LD-PULS impulsegenerator.
Trace gas detectionTrace gas can be used in combinationwith the LD6000 H2 hydrogen sensorto carry out quick and effective leakdetection in pipe networks and pipesystems in houses.
The trace gas used is hydrogen, whichdue to its specific structure is able topenetrate and pass through various ma-terials like soil, concrete, tiles etc. easilybefore then being detected by the sensorat the places where it escapes throughthe system that is being inspected.
The LD6000 is able to show the exactconcentration of hydrogen. The thresh-olds can be individually configured andan acoustic and optical signal warnsthe user when these thresholds havebeen exceeded.
The LD6000 cutting-edgeleak detection device sets
new standards in the fieldof leak detection…
W Acoustic pinpoint leak detection
W Pipe detection
W Long-term measuring with logging function
W Trace gas detection
W All in only one device !
r
t
w
e
y
Grafi
k ©
Trot
ec®
Phone +49 2452 962-400Fax +49 2452 962-200
2
Technical data LD-PULS
Article no. 3.110.008.012
Minimum pressure 2 bar (29 psi) (minimum pressure of the service pipes)
Operating time Approx. 12 hours
Pulse sequence Approx. 60 per minute
Connection 1-inch GEKA high pressure coupling
Power supply Internal battery (rechargeable) or 230V AC
Weight 4.2 kg
Technical data LD6000
Article no. 3.110.008.010
Operating mode Acoustic leak detection (F & V, Smart, long-term measuring),pipe detection and trace gas leak detection
Measuring and device functions
Measuring modes for minimum level, averaged level, pulse wave measurements, simultaneous F&V analysis, logging function, automatic functions for setting filter frequencies and sensor sensitivity, memory preference for manual filter settings, sound level overmodulation protection, trace gas detection with concentration-dependent signal (optic and acoustic)
Controls Either via touchscreen, keys or control dial
Amplification 120 dB low noise factor
Input impedance 1M Ω
Filter Up to 256 can be configured individually (for stick sensor and ground microphone)
Display Colour LCD (automatic illumination), 480 x 272 pixels
Battery check Via micro-controller
Output impedance ≤ 10 Ω
Power supply 4 x batteries type LR14 C 1.5 V
Operating time up to 14 h in non-stop operation, up to 40 h in normal operation
Connections Bayonet nut connector (microphone / sensor), 6.3 mm jack plug (headphones)
Protection class IP54
Housing Aluminium, powder-coated
Temperature conditions During operation: -5 °C to +55 °C; Storage: -25 °C to +65 °C
Dimensions approx. L 210 x W 160 x H 60 mm
Weight approx. 1,050 g
Standard scope of delivery:• LD-PULS – pulse wave generator
built into sturdy case with integratedrechargeable battery
• Separate power supply for LD-PULS
Optionally available accessories:• LD-PULS repair set containing
an Allen key and 4 valves
This impulse generator is excellently-suited for use with the LD6000 meas-uring device.
The LD-PULS is not affected by electriccables and can detect non-metallic wa-ter pipes up to a depth of 2 metreswithout having to close off any part ofthe network or system.
The LD-PULS generates up to 60 oscil-lations per minute which underfavourable conditions can spread outas far as 600 m into the pipe before be-ing detected by a ground microphone.
This means that this method can beused to compile, complete or checkplans and pipe layouts or networks.
LD-PULS pulse wave generator
The principle of acousticleak detection
Water which escapes from high-pres-sure pipes at high speed causes fric-tion which in turn can be picked upin the form of sound waves.
The pipes themselves start to oscil-late. The sound that is generated istransmitted through the pipes andcan be transformed into audiblesound with a body sound micro-phone at a distant contact point(valve, hydrant, armature).
In addition the water leaking outthrough the crack or hole in the pipegenerates sound which is carriedthrough the ground to the surface.This sound can be picked up by ageophone and transformed into au-dible sound.
Trot
ecTe
lem
etry
Plan
ning
and
sur
vey
Tem
pera
ture
Velo
city
Moi
stur
eM
ulti-
func
tion
Trac
ing
and
dete
ctio
nOp
tical
insp
ectio
nsy
stem
sLe
ak d
etec
tion
LEAK DETECTION
3
Standard scope of delivery:• LD6000 measuring device .• LD K – sound blocking headphones e• LD6000 BM – universal microphone
with magnet adapter r• LD6000 DA – tripod adapter t• LD6000 VL – stick extension with tipy• LD6000 TG – shoulder strap u• PC connecting cable• LD6000 carry case
Optionally available accessories:• LD6000 BMW –
wind protected ground microphone (with dead-man’s button) Y
• LD6000 VK – connecting cable• LD6000 DM – tripod magnet for
LD6000 BMW ground microphone o• LD6000 H2 –
hydrogen hand sensorp• LD6000 H2 –
hydrogen ground sensorO
p a
r
t
o
u
w
e
y
i
Technical data LD6000 H2 hydrogen hand and ground sensor
Article no. 3.110.008.111 3.110.008.015
Response sensitivity 1 ppm H₂
Measuring range 10 ppm H₂ to 20,000 ppm H₂
Resolution 1 ppm H₂
Reaction time 0.5 s
Design
Hand sensor with flexible swan-neck (length 50 cm) and 160 cm connecting cable for LD6000Ground sensor with two-part stick microphone (length approx.1 m) and rubber sleeve, approx. 200 cmconnecting cable for LD6000
Temperature conditions During operation: -10 °C to +60 °C; Storage -20 °C to +60 °C
TRT-
KAT-
FDAL
-WM
-05-
EN
r
t
w
e
y
BENEFITS IN PRACTICE:
LD5DL pressure data logger :
Designed specifically for monitoringpressure in water supplies.
Robust, waterproof– no prod contacts
Foil keys for on-site programming
Extremely large memory for more than 240,000 measuring values
Very high measuring sensitivity
Infrared / USB data transfer and infrared / GSM (optional)
Battery life for approx. 10,000,000 measuring values
BENEFITS IN PRACTICE:
LD5L and LD5LR wireless data loggers:
Localisation of leaks using long-term monitoring
Wireless measuring data transfer
Quick logger data read out from moving vehicles
Extremely economical
Sound level detection, analysis and logging
Easy to use
Including LogControl user software, GIS compatible
Sound and pressure data loggerMobile zone monitoring of drinking water systems
Leaks in drinking water systems do not only endanger the quality of your water supply – precious water seeps out uncontrollably resulting in losses worth hundreds or thousands of pounds...
LD5LR standard scope of delivery:• LD5LR receiver (read out device) w• six LD5L data loggers with magnetbase and onboard antenna e
• Switching magnet r• USB cable• LD5L carry case• LogControl software
Optionally available accessories:• LD5L WA – angle adapter for wireless data logger t
• LD5L HYDRO – acoustic wirelessdata logger with hydrophone sensor (hydrophone logger) y
• LD5L HYDRO UF – adapter for hydrophone logger for assembly in DIN hydrant claw, ½-inch innerthread with vent, for assembly with key valve
The mobile wireless monitoringsystem in the Trotec MultiMeasureProfessional Series enables you tocarry out reliable acoustic zonemeasurements in drinking watersystems in order to detect possiblecracks, fissures and leaks.
A magnetic base and optionally availablemounts and brackets allow you to posi-tion your wireless data logger in a va -riety of different positions to measurethe sound levels in the pipe system ornetwork.
In addition, a model with a hydrophonecan be used for measuring operationsthat are carried out with the mediumwater – ideal for plastic pipes or pipenetworks that cover greater distances.
The wireless data loggers detect, analyseand log sound levels during the nightwhen less water flows through the sys-tems and transmits all the measuringdata up to 12 times a minute.
All measuring data can be picked upand logged from a passing vehicle withthe use of a mobile LD5LR receiver.The leak status and further measuringdata are displayed directly on theLD5LR’s easy-to-read display.
All logging data from the LD5LR receivercan be transferred to a PC via the USBinterface for further analysis and docu-mentation.
The LogControl data banksupported software includedin the scope of delivery is
GIS compatible and pro-vides graphic supportedfunctions for analysis andmanagement.
Individual pipe plans canbe transformed into maps,for example; individual log-ger locations and meas-urement series can be as-
signed and individual regions can becreated to establish a borderline be-tween different pressure zones.
Phone +49 2452 962-400Fax +49 2452 962-200
4
Grafik © Trotec
®
Technical data LD5DL pressure data logger
Article no. 3.110.008.130
Sensors (internal) Water pressure sensor, (optional temperature ⁄ air pressuresensor for altitude determination)
Pressure measuringranges
Standard sensor 20 bar; further pressure ranges 1 ⁄ 1.6 ⁄ 2.5 ⁄4 ⁄ 6 ⁄ 10 ⁄ 16 ⁄ 25 bar, possible up to max. 50 bar
Measuring cell Long-term stable, piezo resistive, temperature compensated
Temperature range Up to 70 °C
Measuring accuracy < 1 % from final value at 20 °C
Resolution ± 0.005 % (over the whole measuring range), for example 0.5 mbar at 10 bar measuring range
Measuring interval 1 s to 24 h (can be configured individually), 0.1 s to 1 s (shock pressure recognition)
Real-time clock exact quartz measurement with time and date, starting timeof the measuring data logging can be selected individually
Memory capacity > 240,000 measuring values
Memory type buffered RAM (measuring value conservation during battery change)
Interface Infrared ⁄ USB data transfer (infrared ⁄ GSM optional)
Display LCD
Power supply Lithium battery 3.6 V ⁄ 8.5 AH type AA, battery life approx. 10,000,000 measuring values
Type of housing Stainless steel ⁄ aluminum with internal vent
Protection class IP68
Process connection Standard thread ½-inch hydrant claw
Technical data LD5L wireless data logger
Article no. 3.110.008.120
Data transfer permanent (07:00am to 07:00pm 12x per minute; 07:00pm to 07:00am : 1x per minute.)
Data logging
Statistic minimum level of the previous night, level progressof the past 14 days, quietest level (AL) and loudest level (AH)during the last 10 minutes, amplifier, quality of the measure-ment (rain, wind etc.), logger serial number logger location
Amplification 200,000 times
Recording period 2:00 o’clock to 4 o‘clock
Transmitting power 10 mW
Transmitter frequency 433 MHz (other frequencies on request)
Memory capacity 14-day ring memory
Protection class IP68
Type of housing Nitrogen-filled housing 1.5 bar, condensate protected circuit board
Sensor piezo ceramic
Temperature range -15 °C to +55 °C
Operating time 5 years (without having to change the battery)
Dimensions Dimensions ø 40 ⁄ 44 mm ⁄ Height 110 mm; onboard antenna(english construction); Weight approx. 450 g
Technical data LD5LR receiver
Article no. 3.110.008.110
Description
Statistic minimum level of the previous night, level progress of the past 14 days, quietest and loudest level during the last 10 minutes, selection time, leak status, amplifier, logger serial number
Memory Automatic (the last 14 measuring cycles)
Memory capacity Up to 100 loggers (optionally 2,000 loggers)
Display LCD backlight, 128 x 64 pixels
Transmitter frequency 433 MHz (other frequencies on request)
Power supply 4 x type LR03 AAA 1.5 V batteries
Interface USB
Temperature range -15 °C to +55 °C
Dimensions 200 x 95 x 30 mm, Weight 350 g
LD5DL basic package 1 *• LD5DL – pressure logger with ½-inch outer thread, 0 to 20 bar
• LogControl DL software
LD5DL basic package 2 *• LD5DL UF pressure logger with ½-inch outer thread and below groundhydrant claw, mounted (in compli-ance with DIN), 0 to 20 bar
• Software LogControl DL• Assembly aid with hydrant base DIN
LD5DL basic package 3 * **• LD5DL OF pressure logger with ½-inch outer thread and above groundhydrant claw (3-inch thread), mounted(in compliance with DIN), 0 to 20 bar
• LogControl DL software
Minimum required features: * 1 x LD5DL IR-USB interface (read out device) ** adapter für B-connection incl. B-coupler
The LD5DL pressure data logger hasbeen designed especially for monitoringpressure in water supplies. Its internalvent makes it ideally suited for precisepressure progress measurements forpipe networks and tempering water andfor pressure sampling.
The high sampling rate of up to 10measurements per second enables thelogger to detect even short pressuresurges reliably before logging them.
The LD5DL can store up to 240,000measuring values and present themon its easy-to-read display. The loggeris operated via the USB interface ofyour PC or a GSM module at the loggeritself. Measurements with the LD5DLcan be easily carried out from as littleas one second to several months.
The data stored in the pressure datalog ger can be read out via the IR-USBinterface and transferred to your PCand analysed using the LogControl DLsoftware included in the scope of delivery.
The data banksupported soft-ware enablesyou to proc esssingle meas -
ure ments graphically or transfer variousmeasuring curves. There is also an exportfunction available which allows you toarchive your data flexibly.
Optionally available accessories for LD5DL pressure loggers:
• LD5DL IR-USB interface – read outdevice with for the LD5DL with USBinterface
• LD5DL 20 up to max. 300 bar• External GSM module for LD5DL• Adapter for B-connection incl. B-coupler
• Protective tube for pressure logger with B-coupler
LD5DL pressure data logger
The measuring values logged by the wire-less data logger are transmitted
automatically to the passing vehicle and recorded by
the L5LR receiver.
The measuring engineer can calibrate a leak
directly on site with a correlator or a soundlocator by using the direct optical leak status
indi cator on the display of the receiver if required.
Trot
ecTe
lem
etry
Plan
ning
and
sur
vey
Tem
pera
ture
Velo
city
Moi
stur
eM
ulti-
func
tion
Trac
ing
and
dete
ctio
nOp
tical
insp
ectio
nsy
stem
sLe
ak d
etec
tion
LEAK DETECTION
5
TRT-KA
T-CO
RR-W
M-04-EN
Correlation measurements takeon a whole new dimension withthe mobile PC-based LD20PC all-in-one system. Quality engineering “made in Germany”enables users to identify leaks extremelyflexibly and effectively, thus avoidingexpensive excavations or digging atwrong sites or locations.
The LD20PC is equipped with a steepanalogue filter and a dissipation functionwhich was developed in cooperationwith the Fraunhofer Institute and there-fore able to determine and identifybackground noises and interferencequickly and efficiently before subse-quently effectively suppressing them.
Special optionally available hydrophonesensure accurate results in even the mostdifficult of situations, for example withplastic pipes and long pipe distances.
Advancement through flexibiltyThe countless connection possibilitieswhich the module has to offer providethe user with the greatest possible de-gree of flexibility. As many as four re-ceiver units for three-point correlation
and data logger communication are in-tegrated in the centre of the system.
An optional Bluetooth transmitter allowsyou to conduct wireless measuring ope-rations with the PC correlator overshort distances separate from the sys-tem. Cordless wireless headphonescan be connected to provide you withmore mobility.
A combination comprising high perfor-mance radio transmitters for distancesup to 2,000 metres, an automatic mea-suring mode and a variety of individualsetting options for frequency indepen-dent coherence and correlation analysisand additional wireless data logger ma-
nagement make the LD20PC the idealcorrelator for water suppliers and mea-surement service providers.
LD20PC correlator Multi-functional FFT high-performance correlator for leak detection in pressure pipelines
Unique all-in-one system for mobile loss analysis and reduction in drinkingwater systems.
W FFT high performance correlation at up to three measuring points
W onboard receiver for mobileread out of LD5L wireless data loggers
W mobile wireless data logger management – sound and pressure logger data analysisand management
W all in only one device !
High-performancesoftware with clearly-
structured userinterface
Whether it’s the FFT orthe coherence function
that you are using– theGPS-supported CorControl
software gives you a clear over-view of all measuring data. Parameterslike time signal, spectrum or coherencecan be changed independently after measuring has been carried out.The integrated data management pro-gram allows you to document all datausing the diagram or report function.
Mobile data logger managementThree-point correlation
Highly-sensitive bodysound receiver and
high-performanceradio transmitter
Onboard receiver for wire-less data logger read outfrom moving measurementvehicles
Connection for analysisof LD5DL pressure dataloggers
Optional hydrophonefor direct use with the medium water
Permanent mag -net for trouble-
free mounting
BENEFITS IN PRACTICE:
All-in-one system for mobile loss analysis and reduction in drinking water systems
48 bit three-point correlation
Onboard receiver for wireless datalogger read out from moving vehicles
Read out and analysis of pressure data loggers
GPS-supported map software
FFT and coherence function
Dissipation function for selective squelching
Automatic measuring function
Highly-sensitive sound receiver andhigh-performance radio transmittersfor distances up to 2,000 metres
Multi-functional all-in-one system
Three-point correlationAn optional third receiver and a radiotransmitter with a separate radio fre-quency can be added to the two onboardreceivers which are already standard forthe TR-TA and TR-TB radio transmitters.The three-point correlation enables youto achieve even faster measuring resultsover greater measuring distances.
Mobile data logger managementThe LD20PC’s onboard receiver for wireless data loggers makes theLD20PC excellently-suited for acousticlong-term zone monitoring.
The logger data can be read out from a moving vehicle and analysed and archived with the LogControl data log-ger software used on the correlator.
In addition, the IR interface can be con - nected via the PC correlator’s USB inter-face to read out the LD5DL pressuredata loggers
All measurement values can be dis-played and documented centrally on theLD20PC when used in combination withthe software for pressure data loggers.
The IR interface can also be connected viathe PC correlator’s USB interface to readout the LD5DL pressure data loggers.
Phone +49 2452 962-400Fax +49 2452 962-200
6
Grafik © Trotec
®
Technical data LD20PC
Article no. 3.110.008.210
System module
Sturdy case with built-in PC correlator (notebook) and integrated control panel with connections for headphonejack (automatic mute), transmitter input for optional wire-less headphones, cableless Bluetooth connection for wireless measuring with the PC correlator over short distance separate from the system, onboard receiver modules for wireless sensors and wireless data logger,built-in loudspeakers, connection for antenna as well as power input cable ⁄ charging
Wireless receiverThree onboard receivers : 1 x for LD-TA transmitter, 1 x for LD-TB transmitter, 1 x for LD5DL wireless data logger;optional an additional receiver for third transmitter LD-TC
Power supply
PC correlator (notebook) : external 12 V DC (car adapter)or Ansmann 230 V battery charger; system module : internal rechargeable battery (notebook), external 12 V DC(car adapter) or 230 V AC
System and softwarefunctions
48 bit three-point correlation
Frequency dependent coherence and correlation analysis
FFT analysis; accuracy > 5 cm, correlation resolution:50,000 dots
Automatic or manual measurement with individual parameter settings for measuring distance, filter and amplifier
Chebyshev analogue filter with 48 dB ⁄ octave rise
Calibrating and documentation function
Manual and automatic analogue ⁄ digital filtering to mask interference; high and low-pass filter adjustable from 25 to 2,500 Hz
GIS compatible (acoustic zone monitoring with LogControl)
GPS supported map software
Receiver function to read out wireless data loggers
Connecting port for data logger analysis
Dimensions (system module)
Dimensions L 540 x W 440 x H 220 mm, Weight 11 kg
Technical data LD-TA LD-TB
Article no. 3.110.008.211 3.110.008.212
Transmitter
Display graphic ⁄ numeric, automatic illumination
Displayed valuesCurrent ⁄ minimal sound level,
frequency high ⁄ low, amplification, battery status, battery capacity
Radio frequency 433 ⁄ 434 MHz
Transmitter performance 500 mW (licensed)
Transmittal distance Up to 2,000 m
Operating ⁄ charging time approx. 9 h ⁄ 3 h
Protection class IP65
Dimensions 225 x 165 x 100 mm
Weight 2.9 kg
Signal receiver
Type Piezoceramic
Sensitivity > 1,000 pC ⁄ g
Mounting Permanent magnet
Operating temperature -20 °C to + 60 °C
Standard scope of delivery:• LD20PC – System module with PC
correlator (notebook), control paneland system connections, built into a robust case
• CorControl analysis software• LogControl software for signal recep -
tion of LD5L wireless data loggers• LD-TA –Transmitter 1 incl. signal
receiver, colour yellow• LD-TB– Transmitter 2 incl. signal
receiver, colour red• LD K – soundproof
headphones• Carry case for LD-
TA, LD-TB and sys-tem accessories
Optionally available accessories:• LD-TC – Transmitter 3 incl. signal
receiver, colour blue• LD20PC 3F – Third radio frequency
for transmitter 3 (LD-TC)• LD20 MA – Magnet base antenna
for correlator without amplifier• LD20 MA+ – Magnet base
antenna for correlator with amplifier (4 dB gain)
• LD20 HYDRO – Hydrophone without manometer
• LD20 HYDRO UF – Adapter for hydrophone on DIN
hydrant claw with 1-inch inner threadfor assembly withvalve keys
Correlation is a computer-sup -ported process which can beused to locate leaks extremely
accurately.
All leaks emit sound. This sound travelsand is transferred to hydrants, armaturesand valves. The sound is detected byhighly-sensitive signal receivers at upto three contact measuring points andtransferred to the correlator via the LD
wireless transmitter. The LD20PC calcu-lates the exact position of the leak onthe basis of the differences in the timethat has elapsed between the signalswhile taking various factors like material,pipe diameter and the length of the dis-tance that was measured into account.
When you are trying to detect a leak usingother electroacoustic methods, there area number of factors like the weather, thedepth in which the pipes have been laidor high levels of background noise andother interference which can seriouslyimpair the success of your operation andmake locating the leak extremely difficult.This is not the case when correlation isused to detect a leak.
Why correlation? The benefits of this method…
Trot
ecTe
lem
etry
Plan
ning
and
sur
vey
Tem
pera
ture
Velo
city
Moi
stur
eM
ulti-
func
tion
Trac
ing
and
dete
ctio
nOp
tical
insp
ectio
nsy
stem
sLe
ak d
etec
tion
LEAK DETECTION
7
t
y
w
e
r
u
i
Trotec GmbH & Co. KGGrebbener Str. 7 · D-52525 HeinsbergTel. +49 2452 962-400 · Fax +49 2452 [email protected] · www.trotec.comT
RT-ZBLD
-WM-06-EN
www.trotec-group.com
Grafi
k ©
Trot
ec®
Measuring technological innovations for leak detection in drinking water systems
The LD-series in the MultiMeasure Professional programme provides
you with an optimally matched measuring equipment portfolio for leak
detection in drinking water systems.
All the measuring devices are high-quality, high-precision instruments
which carry all the hallmarks of superior tools made in Germany –
perfectly tuned to cope with the demands that daily use puts on them
w Long-term monitoring with wireless data loggers designed to narrow down leaks.
e Quick logger data read out from a moving vehicle.
r FFT high-performance correlation.
t Acoustic pinpoint detection and route mapping with a combi detector and ground sensor microphone.
y Acoustic body sound measurements
u Trace gas leak detection in drinking water systems.
i Leak detection and leak tightness inspection on housing systems and industrial pipe networks.
And countless more application possibilities !
Do you still have any questions regarding the measuring technological
innovations in the LD-series? If so we would be most glad to help you.
Please feel free to give us a call or go straight to www.trotec.com
where you can find our complete selection of machines, measuring
devices, work tents and safety clothes and equipment.