trinity metro / texrail signage project invitation …...10.14.19.25 update pay phone logo. ref:...

9
ARCHITECTS 1203 DRAGON STREET DALLAS, TEXAS 75207 214.293.5227 WWW.MANNINGARCHITECTS.COM ARCHITECTURE I INTERIORS I PLANNING MANNING 500 WEST SEVENTH STREET FORT WORTH, TEXAS 76102 817.339.8950 WWW.TRANSYSTEMS.COM TRINITY METRO TRINITY METRO / TEXRAIL SIGNAGE PROJECT INVITATION FOR BIDS TRINITY METRO RECOMMENDED: PROJECT MANAGER DATE BO CUNG, P.E. SENIOR VICE PRESIDENT DATE BOB BAULSIR FACILITIES # NAME 1. FORT WORTH CENTRAL STATION 1001 JONES STREET FORT WORTH, TEXAS 76102 2. TEXAS & PACIFIC STATION 200 WEST VICKERY BOULEVARD FORT WORTH, TEXAS 76102 3. TEXRAIL EQUIPMENT MAINTENANCE FACILITY 3801 TEXRAIL DRIVE FORTH WORTH, TEXAS 76137 4. IRONHORSE STATION 6400 IRONHORSE BOULEVARD NORTH RICHLAND HILLS, TEXAS 76180 5. SMITHFIELD STATION 6416 SMITHFIELD ROAD NORTH RICHLAND HILLS, TEXAS 76182 6. GRAPEVINE/ MAIN STREET STATION 815 SOUTH MAIN STREET GRAPEVINE, TEXAS 76051 7. DFW TERMINAL B STATION 2311 INTERNATIONAL PARKWAY DALLAS FORT WORTH AIRPORT TARRANT COUNTY LOCATION MAP 01 02 NOT TO SCALE 03 04 05 06 07

Upload: others

Post on 03-Oct-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: TRINITY METRO / TEXRAIL SIGNAGE PROJECT INVITATION …...10.14.19.25 update pay phone logo. ref: 02/a201. 10.14.19.26 remove existing door signage (6 locations), clean adhesive from

ARCHITECTS

1203 DRAGON STREET

DALLAS, TEXAS 75207

214.293.5227

WWW.MANNINGARCHITECTS.COM

ARCHITECTURE I INTERIORS I PLANNING

MANNING

500 WEST SEVENTH STREET

FORT WORTH, TEXAS 76102

817.339.8950

WWW.TRANSYSTEMS.COM

TRINITY METRO

TRINITY METRO / TEXRAIL

SIGNAGE PROJECT

INVITATION FOR BIDS

TRINITY METRO

RECOMMENDED:

PROJECT MANAGER DATE

BO CUNG, P.E.

SENIOR VICE PRESIDENT DATE

BOB BAULSIR

FACILITIES# NAME

1. FORT WORTH CENTRAL STATION

1001 JONES STREET

FORT WORTH, TEXAS 76102

2. TEXAS & PACIFIC STATION

200 WEST VICKERY BOULEVARD

FORT WORTH, TEXAS 76102

3. TEXRAIL EQUIPMENT MAINTENANCE FACILITY

3801 TEXRAIL DRIVE

FORTH WORTH, TEXAS 76137

4. IRONHORSE STATION

6400 IRONHORSE BOULEVARD

NORTH RICHLAND HILLS, TEXAS 76180

5. SMITHFIELD STATION

6416 SMITHFIELD ROAD

NORTH RICHLAND HILLS, TEXAS 76182

6. GRAPEVINE/ MAIN STREET STATION

815 SOUTH MAIN STREET

GRAPEVINE, TEXAS 76051

7. DFW TERMINAL B STATION

2311 INTERNATIONAL PARKWAY

DALLAS FORT WORTH AIRPORT

TARRANT COUNTY

LOCATION MAP

0102

NOT TO SCALE

03

04

05

06 07

TEXRAIL SIGNAGE PROJECT

gdickey
Typewritten Text
gdickey
Typewritten Text
gdickey
Typewritten Text
gdickey
Typewritten Text
gdickey
Typewritten Text
gdickey
Typewritten Text
gdickey
Typewritten Text
gdickey
Typewritten Text
gdickey
Typewritten Text
gdickey
Typewritten Text
gdickey
Typewritten Text
gdickey
Typewritten Text
gdickey
Typewritten Text
gdickey
Typewritten Text
gdickey
Typewritten Text
gdickey
Typewritten Text
gdickey
Typewritten Text
gdickey
Typewritten Text
gdickey
Typewritten Text
gdickey
Typewritten Text
gdickey
Typewritten Text
IFB 19-T045
gdickey
Typewritten Text
gdickey
Typewritten Text
gdickey
Typewritten Text
Page 2: TRINITY METRO / TEXRAIL SIGNAGE PROJECT INVITATION …...10.14.19.25 update pay phone logo. ref: 02/a201. 10.14.19.26 remove existing door signage (6 locations), clean adhesive from

ABBREVIATIONS

ACOUS. ACOUSTICALACT ACOUSTICAL CEILING TILEA.D. AREA DRAINADJ. ADJACENTADJUST. ADJUSTABLEA.F.F. ABOVE FINISHED FLOORA.F.G ABOVE FINISH GRADEALUM. ALUMINUMAPPROX. APPROXIMATELYASB. ASBESTOSATTEN. ATTENUATIONBR. BRICKBD. BOARDBLDG. BUILDINGBLK. BLOCKBM. BEAMBOL. BOLLARDCAR. CARPETC.B. CATCH BASINC.G. CORNER GUARDC.J. CONTROL JOINTC.M.U. CONCRETE MASONRY UNITC.O. CLEAN OUTC.R. COLD ROLLEDCAB. CABINETCEM. CEMENTCLG. CEILINGCOL. COLUMNCONC. CONCRETECONST. CONSTRUCTIONCONT. CONTINUOUSCPT. CARPET TILEC.T. CERAMIC TILEDBL. DOUBLEDEMO. DEMOLITIONDTL DETAILDIA. DIAMETERDIAG. DIAGONALDIM. DIMENSIONDISP. DISPENSERDN. DOWNDWG. DRAWINGEA. EACHE.J. EXPANSION JOINTEL. ELEVATIONELECT. ELECTRICALENAM. ENAMELEQ. EQUALEQUIP. EQUIPMENTE.W. EACH WAYE.W.C. ELECTRICAL WATER COOLEREXIST. EXISTINGEXP. EXPANSIONEXT. EXTERIORF.D. FLOOR DRAINF.H. FLAT HEADFDN. FOUNDATIONFIN. FINISHFLR. FLOORFLUOR. FLUORESCENTFOC. FACE OF CONC.(MAS.)F.E.C. FIRE EXITINGUISHING CABINETF.H.C. FIRE HOSE CABINETF.R. FIRE RESISTANCEFRM. FRAMEFRP FIBERGLASS REINFORCEMENT PANELFT. FOOTG.I. GALVANIZED IRONGA. GUAGEGALV. GALVANIZEDGEN. GENERALGL. GLASSGR. GRANITEGYP. GYPSUMGYP. BD. GYPSUM BOARDHC HANDICAPPEDH.M. HOLLOW METALH.R. HANDRAILHORIZ. HORIZONTALHT. HEIGHTI.D. INSIDE DIAMETER

PROJECT DATA AND CODE SUMMARY

APPLICABLE CODES

CITY OF FORT WORTH

2015 INTERNATIONAL BUILDING CODE2015 INTERNATIONAL FIRE CODE2015 INTERNATIONAL PLUMBING CODE2015 INTERNATIONAL MECHANICAL CODE2017 INTERNATIONAL ENERGY CODE2017 NATIONAL ELECTRICAL CODE2012 TEXAS ACCESSIBILITY STANDARDSCITY OF FORT WORTH ZONING ORDINANCE, ARTICLE 4. SIGNS

PROJECT BRIEF

THE FORT WORTH TRANSPORTATION AUTHORITY (PREVIOUSLY BRANDED AS "THE T") HAS CHANGED THEIR BRANDED NAME TO BE "TRINITY METRO". THE CHANGE RESULTED IN A NEED TO UPDATE SIGNAGE AT MANY OF THEIR FACILITIES. THIS PROJECT IS TO ASSIST THEM IN ACCOMPLISHING THAT GOAL.

THIS PROJECT INCLUDES METALWORK, REPLACEMENT OF IN-KIND SIGNAGE GRAPHICS ON EXISTING AGENCY SIGN FACES, INSTALLATION OF NEW SIGNAGE AND INSTALLATION OF SIGNAGE LIGHTING.

FACILITIES INCLUDED IN THIS EFFORT ARE:

1. FORT WORTH CENTRAL STATION1001 JONES STREETFORT WORTH, TEXAS 76102

2. TEXAS & PACIFIC STATION200 WEST VICKERY BOULEVARDFORT WORTH, TEXAS 76102

GENERAL NOTES

DIMENSIONS ARE SHOWN TO FACE OF FINISHES, UNLESS OTHERWISE INDICATED.

DO NOT SCALE DRAWINGS. CONSULT WITH ARCHITECT FOR CLARIFICATIONS.

THE CONTRACTOR(S) SHALL BE RESPONSIBLE FOR BUILDING THIS PROJECT IN ACCORDANCE WITH THE DRAWINGS AND SPECIFICATIONS, UNLESS OTHERWISE NOTIFIED IN WRITING BY THE OWNER OR ARCHITECT.

ALL WORK SHALL BE IN COMPLIANCE WITH THE CURRENT VERSION OF ALL APPLICABLE CODES AND THE AMERICAN DISABILITIES ACT / TEXAS ACCESSIBILITY STANDARDS. CONTRACTOR SHALL NOTIFY ARCHITECT OF ANY DEFICIENCIES PRIOR TO THE COMPLETION OF WORK.

CONTRACTOR SHALL PROVIDE PUBLIC PROTECTIONS NECESSARY PER ALL APPLICABLE REGULATIONS.

CONTRACTOR WILL COORDINATE WITH OWNER PARKING ON OR OFF SITE. ONLY EQUIPMENT FOR CONSTRUCTION MAY BE PARKED ON SITE.

THE LOCATION OF THE EXISTING UTILITIES AND STRUCTURES SHOWN HEREON ARE APPROXIMATE. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE VERIFICATION OF THE EXISTENCE AND ACTUAL LOCATION OF SUCH, WHETHER SHOWN HEREON OR NOT, PRIOR TO ANY EXCAVATION. ANY DAMAGES SHALL BE REPAIRED AT THE EXPENSE OF THE GENERAL CONTRACTOR.

THE SEQUENCE OF INSTALLTION OF ALL ELEMENTS WITHIN AN ASSEMBLY, TO ASSURE THE CONSTRUCTIBILITY, IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. QUERIES BY THE GENERAL CONTRACTOR REGARDING CONSTRUCTIBILITY OF ANY ASSEMBLY SHALL BE ADDRESSED TO THE ARCHITECT FOR REVIEW IN A TIMELY MANNER, IN ORDER FOR THE ARCHITECT TO REVIEW AND COORDINATE WITH OTHER DISCIPLINES, AND TO ENSURE THE CONSTRUCTION SCHEDULE IN NOT ADVERSELY IMPACTED.

CONTRACTOR SHALL PROTECT CONSTRUCTION INDICATED TO REMAIN AGAINST DAMAGE AND SOILING DURING DEMOLITION.

CONTRACTOR SHALL NOTIFY ARCHITECT AND OWNER OF ANY DEFECTS AND / OR DAMAGED / DECAYING MATERIALS FOUND IN THE EXISTING STRUCTURE OR WORK PRIOR TO ENCLOSING NEW CONSTRUCTION.

THE EXISTING PLAN IS DOCUMENTED ON THE DRAWINGS IN ACCORDANCE WITH A LIMITED NUMBER OF AVAILABLE ORIGINAL CONSTRUCTION DRAWINGS AND FIELD INVESTIGATIONS. VARIANCE OF ACTUAL EXISTING CONDITIONS FROM THOSE ILLUSTRATED ON THESE DOCUMENTS MAY OCCUR. THE GENERAL CONTRACTOR SHALL VERIFY EXISTING CONDITIONS PRIOR TO COMMENCING WORK AND REPORT ANY AND ALL DISCREPANCIES TO THE ARCHITECT.

ALL EXISTING ITEMS TO REMAIN UNLESS OTHERWISE NOTED.

THE CONTRACTOR IS TO COORDINATE ALL SHUT DOWNS OR INTERRUPTIONS IN ANY SERVICE WITH THE OWNER PRIOR TO PROCEEDING WITH WORK.

IN. INCHINSUL. INSULATIONINT. INTERIORINV. INVERTJ.B. JUNCTION BOXJT. JOINTLAV. LAVATORYLM LIMESTONELT.WT. LIGHT WEIGHTMA MARBLEM.H. MANHOLEMACH. MACHINEMANUF. MANUFACTURERMAX. MAXIMUMMECH. MECHANICALMET., MTL. METALMIN. MINIMUMM.T. METAL THRESHOLDN.I.C. NOT IN CONTRACTNOM. NOMINALNTS. NOT TO SCALEO.C. ON CENTERO.D. OUTSIDE DIAMETEROPG. OPENINGPT. PAINTPARTN. PARTITIONPL. PLASTIC LAMINATEPLAS. PLASTERPLWD. PLYWOODQ.T. QUARRY TILER METAL ROOF FINISHR.B. RESILIENT BASER.D. ROOF DRAINRAD. RADIUSREF REFERENCEREC. RECESSEDREINF. REINFORCEDREQ'D REQUIREDRET. RETAININGRM. ROOMR.O. ROUGH OPENINGR.T. RESILIENT TILESEAL SEALANTS.S. STAINLESS STEELSCHED. SCHEDULESECT. SECTIONSF SPECIAL FINISHSH SHUTTERSHT. SHEETSIM. SIMILARSL. SLOPESPEC. SPECIFICATIONSQ. SQUARESTD. STANDARDSTL. STEELSTRUCT. STRUCTURALSUSP. SUSPENDEDSVT SPECIALTY VINYL TILET. TREADSTA. TOILET ACCESSORYT.&B. TOP & BOTTOMT.C. TOP OF CURBT.&G., TNG TONGUE & GROOVET.O.C. TOP OF CONCRETET.O.S. TOP OF STEELTEL. TELEPHONETERR. TERRAZZOTHRU. THROUGHTYP. TYPICALU.N.O. UNLESS NOTED OTHERWISEUR. URINALV.C.P. VERIFIED CLAY PIPEV.C.T. VINYL COMPOSITION TILEVERT. VERTICALVSF VINYL SHEET FLOORINGV.W.C. VINYL WALL COVERINGW/ WITHW.C. WATER COOLERW.F. WIDE FLANGEW.P. WATERPROOFW.W.F. WELDED WIRE FABRICWATER RES. WATER-RESISTANTWD. WOOD

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

SEE DISCIPLINE SHEETS FOR DISCIPLINE SPECIFIC SYMBOLS

0 GRID LINE

CENTER LINE

REVISION NUMBER1

CL

INTERIOR ELEVATION

DETAIL SECTION /

CALL OUT HEAD

BUILDING SECTIONA-301

1

IA-211

A501

1

1

3

4 2

DETAIL

SHEET

DETAIL

SHEET

DETAIL

SHEET

SHEET TYPE

DISCIPLINE

IA 101

NORTH ARROWS

N

SHEET NUMBER

PROJECT

TRUE

SYMBOL LEGEND

SHEET No.

ARCHITECTS

1203 DRAGON STREET

DALLAS, TEXAS 75207

214.293.5227

WWW.MANNINGARCHITECTS.COM

ARCHITECTURE I INTERIORS I PLANNING

MANNING

DWG No. REV

REV DATE DESCRIPTION BY DES APRCHKTBAE REGISTRATION No. 19484

TBPE FIRM REGISTRATION No. F-3557TBPLS FIRM REGISTRATION No. 100383

500 WEST SEVENTH STREET

FORT WORTH, TEXAS 76102

817.339.8950

WWW.TRANSYSTEMS.COM

TRINITY METRO

SCALE

DRAWN

DESIGNED

CHECKED

IN CHARGE

DATE

TRINITY METROFACILITIES UPGRADE PROJECT

GENERAL NOTES AND DRAWINGINDEX - PKG 1

G001.1

INDEX OF DRAWINGS

Sheet

Number Sheet Name

G000.1 COVER SHEEET - PKG 1

G001.1 GENERAL NOTES AND DRAWING INDEX - PKG 1

A101 FORT WORTH CENTRAL STATION - SITE PLAN

A111 TEXAS & PACIFIC COMMUTER RAIL STATION - SITE PLAN

A112 TEXRAIL EQUIPMENT MAINTENANCE FACILITY - SITEPLAN

A201 FORT WORTH CENTRAL STATION - ELEVATIONS

A209 SIGNAGE DETAILS

A210.1 TEXAS & PACIFIC STATION PYLON SIGN - ELEVATION

A211 TEXRAIL EQUIPMENT MAINTENANCE FACILITY -ELEVATION

N.T.S

CK

CK

CC

RM

TEXRAIL SIGNAGE PROJECT

APRTBAE REGISTRATION No. 19484

August 27, 2019

Page 3: TRINITY METRO / TEXRAIL SIGNAGE PROJECT INVITATION …...10.14.19.25 update pay phone logo. ref: 02/a201. 10.14.19.26 remove existing door signage (6 locations), clean adhesive from

JON

ES

STR

EE

T

CA

LH

OU

N S

TR

EE

T

E. 11TH S

TREET

E. 9TH S

TREET

FORT WORTH CENTRAL STATION

1001 JONES STREET

FORT WORTH, TEXAS 76102

RA

IL S

TA

TIO

N P

LA

TFO

RM

S

BUS P

LA

TFO

RM

S

REFER TO APPENDIX A - SIGN LOCATIONS & ELEVATIONS FOR ADDITIONAL INFORMATION IN THIS AREA.

REFER TO APPENDIX A - SIGN LOCATIONS & ELEVATIONS, PGS. 16 & 17 FOR ADDITIONAL INFORMATION IN THIS AREA.

A201

01

A201

04

A201

04

10.14.19.26

10.14.19.25

10.14.19.25

10.14.19.26

10.14.19.26

A201

04

A201

05

10.14.19.25

10.14.19.25

A201

03

A201

06

A201

06

A201

04

04

A210.1

03

SHEET No.

ARCHITECTS

1203 DRAGON STREET

DALLAS, TEXAS 75207

214.293.5227

WWW.MANNINGARCHITECTS.COM

ARCHITECTURE I INTERIORS I PLANNING

MANNING

DWG No. REV

REV DATE DESCRIPTION BY DES APRCHKTBAE REGISTRATION No. 19484

TBPE FIRM REGISTRATION No. F-3557TBPLS FIRM REGISTRATION No. 100383

500 WEST SEVENTH STREET

FORT WORTH, TEXAS 76102

817.339.8950

WWW.TRANSYSTEMS.COM

TRINITY METRO

SCALE

DRAWN

DESIGNED

CHECKED

IN CHARGE

DATE

TRINITY METROFACILITIES UPGRADE PROJECT

FORT WORTH CENTRAL STATION -SITE PLAN

A101

1" = 100'-0"A101

01 FORT WORTH CENTRAL STATION - SITE PLAN

1" = 100'

CK

CK

CC

RM

KEYNOTES

10.14.19.25 UPDATE PAY PHONE LOGO. REF: 02/A201.

10.14.19.26 REMOVE EXISTING DOOR SIGNAGE (6 LOCATIONS), CLEANADHESIVE FROM GLASS AND RE-INSTALL NEW DOOR SIGNAGEWITH UPDATED LOGO.

NORTH

0' 50' 100' 200'

TEXRAIL SIGNAGE PROJECT

APRTBAE REGISTRATION No. 19484

August 27, 2019

Page 4: TRINITY METRO / TEXRAIL SIGNAGE PROJECT INVITATION …...10.14.19.25 update pay phone logo. ref: 02/a201. 10.14.19.26 remove existing door signage (6 locations), clean adhesive from

TEXAS & PACIFIC COMMUTER RAIL STATION

221 WEST LANCASTER STREET

FORT WORTH, TEXAS 76102

WEST VICKERY BOULEVARD

SO

UTH

MA

IN S

TREET

INTERSTATE 30

A210.101A210.1 01

SHEET No.

ARCHITECTS

1203 DRAGON STREET

DALLAS, TEXAS 75207

214.293.5227

WWW.MANNINGARCHITECTS.COM

ARCHITECTURE I INTERIORS I PLANNING

MANNING

DWG No. REV

REV DATE DESCRIPTION BY DES APRCHKTBAE REGISTRATION No. 19484

TBPE FIRM REGISTRATION No. F-3557

TBPLS FIRM REGISTRATION No. 100383

500 WEST SEVENTH STREET

FORT WORTH, TEXAS 76102

817.339.8950

WWW.TRANSYSTEMS.COM

TRINITY METRO

SCALE

DRAWN

DESIGNED

CHECKED

IN CHARGE

DATE

TRINITY METRO

FACILITIES UPGRADE PROJECT

TEXAS & PACIFIC COMMUTER RAIL

STATION - SITE PLAN

A111

1" = 50'-0"A111

01 TEXAS & PACIFIC COMMUTER RAIL STATION - SITE PLAN

1" = 50'

CK

CK

CC

RM

NORTH

0' 25' 50' 100'

REFER TO APPENDIX A - SIGN

LOCATIONS & ELEVATIONS FOR

ADDITIONAL INFORMATION

REGARDING STATION TUNNEL,

PLATFORM AND CONCOURSE

SIGNAGE.

TEXRAIL SIGNAGE PROJECT

APRTBAE REGISTRATION No. 19484

August 27, 2019

Page 5: TRINITY METRO / TEXRAIL SIGNAGE PROJECT INVITATION …...10.14.19.25 update pay phone logo. ref: 02/a201. 10.14.19.26 remove existing door signage (6 locations), clean adhesive from

A211

01

TEXRAIL EQUIPMENT MAINTENANCE FACILITY

3801 TEXRAIL DRIVE

FORT WORTH, TEXAS 76137

NO

RTH

SY

LV

AN

IA A

VEN

UE

SYLVANIA CROSS DRIVE

SHEET No.

ARCHITECTS

1203 DRAGON STREET

DALLAS, TEXAS 75207

214.293.5227

WWW.MANNINGARCHITECTS.COM

ARCHITECTURE I INTERIORS I PLANNING

MANNING

DWG No. REV

REV DATE DESCRIPTION BY DES APRCHKTBAE REGISTRATION No. 19484

TBPE FIRM REGISTRATION No. F-3557

TBPLS FIRM REGISTRATION No. 100383

500 WEST SEVENTH STREET

FORT WORTH, TEXAS 76102

817.339.8950

WWW.TRANSYSTEMS.COM

TRINITY METRO

SCALE

DRAWN

DESIGNED

CHECKED

IN CHARGE

DATE

TRINITY METRO

FACILITIES UPGRADE PROJECT

TEXRAIL EQUIPMENT MAINTENANCE

FACILITY - SITE PLAN

A112

1" = 100'

CK

CK

CC

RM

1" = 100'-0"A112

01 TEXRAIL EQUIPMENT MAINTENANCE FACILITY - SITE PLAN

TEXRAIL SIGNAGE PROJECT

APRTBAE REGISTRATION No. 19484

August 27, 2019

Page 6: TRINITY METRO / TEXRAIL SIGNAGE PROJECT INVITATION …...10.14.19.25 update pay phone logo. ref: 02/a201. 10.14.19.26 remove existing door signage (6 locations), clean adhesive from

SIGN TYPES C03 - C05, C09

TRINITY METRO

EQ 8' - 10 1/4" EQ

2' -

0"

1' -

10

1/2

"

2' - 0"

2' -

0"

2' - 0"

EQ EQ EQ EQ

SIGN TYPE C03 (1 EA)

SIGN TYPE C04 (1 EA)

SIGN TYPE C05 (1 EA)10.14.19.08

08.81.23.01

08.81.23.01

05.00.00.02

05.00.00.01

10.14.19.14

10.14.19.15

10.14.19.16

10.14.19.15

05.00.00.02

05.00.00.01

ECHTROWTROF

NT RAL S TAT IONSIGN TYPE C09 (1 EA)

10.14.19.10

05.00.00.03

05.00.00.04

10.14.19.16

TRINITY METROTICKETS INFORMATION&

8' - 5"

5 3

/4"

8' - 10"

11"

6" TRINITY METRO

TE Rail 6"

1' - 5 3/4"6 1/2"3' - 9"10"10 1/2"

9 1

/2"

10.14.19.18

10.14.19.19 10.14.19.15

10.14.19.14

10.14.19.16

10.14.19.15

10.14.19.14

10.14.19.15

10.14.19.16

SIGN TYPE C01 (2 EA) SIGN TYPE C02 (2 EA)

Information Desk Hours

Mon. - Fri. 6 am - 5 pmSaturday 8 am - 5 pmSunday Closed

Effective August 1, 2019

SIGN TYPE C08 (6 EA)

5"

7"

BOARDING

2' -

6"

V.I

.F.

1' - 8" V.I.F.

BOARDING

2' -

6"

V.I

.F.

1' - 8" V.I.F.

TB

RU

AS

IE

NS

S

SIGN TYPE C10A SIGN TYPE C108

T B

R U

A S

I E

N S

S

10.14.19.28

10.14.19.28

TRINITY METRO TRINITY METRO

RELOCATE EXIST.AMTRAK LOGO

RELOCATE EXIST.ENTERPRISE LOGO

RELOCATE EXIST.SUBWAY LOGO

RELOCATE EXIST.GREYHOUND LOGO

SIGN TYPE C13

SHEET No.

ARCHITECTS

1203 DRAGON STREET

DALLAS, TEXAS 75207

214.293.5227

WWW.MANNINGARCHITECTS.COM

ARCHITECTURE I INTERIORS I PLANNING

MANNING

DWG No. REV

REV DATE DESCRIPTION BY DES APRCHKTBAE REGISTRATION No. 19484

TBPE FIRM REGISTRATION No. F-3557TBPLS FIRM REGISTRATION No. 100383

500 WEST SEVENTH STREET

FORT WORTH, TEXAS 76102

817.339.8950

WWW.TRANSYSTEMS.COM

TRINITY METRO

SCALE

DRAWN

DESIGNED

CHECKED

IN CHARGE

DATE

TRINITY METROFACILITIES UPGRADE PROJECT

FORT WORTH CENTRAL STATION -ELEVATIONS

A201

1/2" = 1'-0"A201

01 CENTRAL STATION - MONUMENT SIGN

1/2" = 1'-0"A201

04 CENTRAL STATION - KIOSK ELEVATIONS

KEYNOTES

05.00.00.01 RE-USE EXISTING STEEL BACKING PLATE. CLEAN AND PREPAREFOR NEW GRAPHICS FILM AS NECESSARY.

05.00.00.02 RE-USE EXISTING 1" CYLINDER STAINLESS STEEL STAND-OFF.CLEAN AND PREPARE AS NECESSARY

05.00.00.03 1/8" STAINLESS STEEL SIGN FACE. BRUSHED FINISH

05.00.00.04 1 1/2" CYLINDER STAINLESS STEEL STAND-OFF. ANCHOR INTOEXISTING LIMESTONE

08.81.23.01 RE-USE EXISTING ACRYLIC / GLASS SIGNAGE PANEL. INSTALLNEW SIGNAGE GRAPHICS AS SHOWN.

10.14.19.08 DIMENSIONAL LETTERS - FABRICATED METAL, POLISHEDSTAINLESS STEEL, 3" EXTRUSION DEPTH, PROXIMA NOVASEMI-BOLD, SIZE AS SHOWN

10.14.19.10 DIMENSIONAL LETTERS - CUT VINYL, PROXIMA NOVASEMI-BOLD, 3M SCREEN PRINTING UV INK SERIES 9800 ORAPPROVED EQUAL, SIZE AS SHOWN. COLOR TO MATCHPANTONE PMS 281C

10.14.19.14 PRINT LOGO DECAL - CUT VINYL, 3M SCREEN PRINTING UV INKSERIES 9800 OR APPROVED EQUAL, SIZE AS SHOWN. COLOR TOMATCH PANTONE PMS 430C

10.14.19.15 PRINT LOGO DECAL - CUT VINYL, 3M SCREEN PRINTING UV INKSERIES 9800 OR APPROVED EQUAL, SIZE AS SHOWN. COLOR TOMATCH PANTONE PMS 281C

10.14.19.16 PRINT LOGO DECAL - CUT VINYL, 3M SCREEN PRINTING UV INKSERIES 9800 OR APPROVED EQUAL, SIZE AS SHOWN. COLOR TOMATCH PANTONE PMS 185C

10.14.19.18 DIMENSIONAL LETTERS - CUT VINYL, PROXIMA NOVA BLACK, 3MSCREEN PRINTING UV INK SERIES 9800 OR APPROVED EQUAL,SIZE AS SHOWN. COLOR TO MATCH PANTONE PMS 281C

10.14.19.19 DIMENSIONAL LETTERS - CUT VINYL, PROXIMA NOVA LIGHT, 3MSCREEN PRINTING UV INK SERIES 9800 OR APPROVED EQUAL,SIZE AS SHOWN. COLOR TO MATCH PANTONE PMS 281C

10.14.19.28 DIMENSIONAL LETTERS - CUT VINYL, PROXIMA NOVA BLACK, 3MSCREEN PRINTING UV INK SERIES 9800 OR APPROVED EQUAL,SIZE AS SHOWN. COLOR WHITE

AS SHOWN

CK

CK

CC

RM

6" = 1'-0"A201

05 CENTRAL STATION -DOOR STICKER

1" = 1'-0"A201

06 CENTRAL STATION - BOARDING SIGN

1

D

2

W

AR

M

APRTBAE REGISTRATION No. 19484

APRTBAE REGISTRATION No. 19484

August 27, 2019

Page 7: TRINITY METRO / TEXRAIL SIGNAGE PROJECT INVITATION …...10.14.19.25 update pay phone logo. ref: 02/a201. 10.14.19.26 remove existing door signage (6 locations), clean adhesive from

1"

1"

6"

9"

2' - 6"

EXIST. WALL

5/16" STEEL

PLATE

SET SCREW

SET SCREW

SUPPORTING STEEL BASE

PLATE

1/2" EXPANSION BOLT

3' - 3"

1' - 10 1/4" 1' - 1 1/2"

2' - 6"

WELD AROUND

STEEL TUBE PERIMETER.

GRIND WELDS SMOOTH.

PRIME AND PAINT TO

MATCH EXIST.

1/4"-20 SS

THREADED ROD

3/4" DIA. X 1/2"

THREADED S.S. CAP

3/4" DIA. X 1/2"

THREADED S.S. CAP

HSS7X4X5/6

TRINTIY METRO

SIGNAGE

EXISTING MASONRY WALL

1/2" EXPANSION ANCHOR

1" X 1" SS SPACER

1/4" POWDER COATED

ALUMINUM SIGN FACE

1 1

/2"

1"

1"

SET SCREW

SET SCREW

5/16" STEEL

PLATE

6"2' - 6"

1' - 1 1/2"

2' - 6"

EXIST. STEEL POLE

S.S. CLAMPS

WELD AROUND

STEEL TUBE PERIMETER.

GRIND WELDS SMOOTH.

PRIME AND PAINT TO

MATCH EXIST.

SUPPORTING STEEL BASE

PLATE

1/4"-20 SS

THREADED ROD

3/4" DIA. X 1/2"

THREADED S.S. CAP

3/4" DIA. X 1/2"

THREADED S.S. CAP

HSS7X4X5/6

9"

1' - 10 1/4"

3' - 3"

TRINTIY METRO

SIGNAGE

EXIST. STEEL

COL. FLANGE

1/4"-20 S.S.

THREADED ROD

3/4" DIA. X 1/2"

THREADED S.S. CAP

3/4" DIA. X 1/2"

THREADED S.S. CAP

6"

1' -

2"

7' - 6"

HSS7X4X5/6

4" X 4 X 1/4" ANGLE

BRACKET, WELD

ALL AROUND TO

COLUMN FLANGE

SET SCREW

SET SCREW

4" 5" 6' - 0" 5" 4"

1/4"-20 S.S.

THREADED RODS

TRINTIY METRO

SIGNAGE

2 1/2" 2 1/2"

3 1

/2"

3 1

/2"

4" X 4 X 1/4" ANGLE

BRACKET, WELD

ALL AROUND TO

COLUMN FLANGE

3' - 3"

1' - 10 1/4" 1' - 1 1/2"

1"

1"

1/2

"

2' - 6" 6"

9"

4 1

/2"

4"1' - 6"

2' - 6"

1/4"-20 SS

THREADED ROD

3/4" DIA. X 1/2"

THREADED SS CAP

3/4" DIA. X 1/2"

SS SPACER

3/4" DIA. X 1/2"

THREADED SS CAP

HSS7X4X5/6

EXIST. STEEL

COL. FLANGE

WELD AROUND

STEEL TUBE PERIMETER.

GRIND WELDS SMOOTH.

PRIME AND PAINT TO

MATCH EXIST.

5/16" STEEL

PLATE

SET SCREW

SET SCREW

TRINTIY METRO

SIGNAGE

SHEET No.

ARCHITECTS

1203 DRAGON STREET

DALLAS, TEXAS 75207

214.293.5227

WWW.MANNINGARCHITECTS.COM

ARCHITECTURE I INTERIORS I PLANNING

MANNING

DWG No. REV

REV DATE DESCRIPTION BY DES APRCHKTBAE REGISTRATION No. 19484

TBPE FIRM REGISTRATION No. F-3557

TBPLS FIRM REGISTRATION No. 100383

500 WEST SEVENTH STREET

FORT WORTH, TEXAS 76102

817.339.8950

WWW.TRANSYSTEMS.COM

TRINITY METRO

SCALE

DRAWN

DESIGNED

CHECKED

IN CHARGE

DATE

TRINITY METRO

FACILITIES UPGRADE PROJECT

SIGNAGE DETAILS

A209

1" = 1'-0"A209

04 TRACK SIGNAGE, WALL MOUNT

1 1/2" = 1'-0"A209

03 T&P CONCOURSE SIGNAGE, WALL MOUNT1" = 1'-0"A209

02 TRACK SIGNAGE, POLE MOUNT

1" = 1'-0"A209

01 T&P PLATFORM SIGNAGE

1" = 1'-0"A209

05 TRACK SIGNAGE, COLUMN MOUNT

TEXRAIL SIGNAGE PROJECT

SCALE

DRAWN

DESIGNED

CHECKED

IN CHARGE

DATE

AS SHOWN

CK

CK

CC

RM

APRTBAE REGISTRATION No. 19484

August 27, 2019

Page 8: TRINITY METRO / TEXRAIL SIGNAGE PROJECT INVITATION …...10.14.19.25 update pay phone logo. ref: 02/a201. 10.14.19.26 remove existing door signage (6 locations), clean adhesive from

STATIONPARK & RIDE

200 W VICKERY BLVDFORT WORTH

TRINITY METRO

TEXAS &PACIFIC

8 1

/4"

4"

2"

4"

1' -

6"

4"

5 1

/4"

1"

5 1

/4"

1"

5 1

/4"

1"

3 3

/4"

2 1

/2"

1' -

0 1

/2"

3 1

/2"

1"

3 1

/2"

2 1

/2"

10"

1' -

4"

10.14.19.15

10.14.19.12

10.14.19.13

10.14.19.12

10.14.19.15

10.14.19.20

10.14.19.17

10.14.19.15

10.14.19.15

10.14.19.16

09.91.00.08

10.14.19.11

SIGN TYPE C01 (2 EA)

EQ2' - 0"6 1/2"1' - 2 1/2"EQ

10.14.19.20

FORT WORTHCENTRAL STATION

The Fort Worth Transportation Authority dedicates this public space to the citizens it serves as a lasting commitment to regional mobility.

EXECUTIVE COMMITTEE MEMBERS

Gyna M. Bivens

Eduardo Canas

Paul N. Giesel

Gregory W. Hughes

J. R. Kimball, MAI

William T. Leonard

David L. Ragan

Richard F. Spraberry

Frank B. Staton

President / Executive Director

John P. Bartosiewicz

January 12, 2002

FORT WORTHCENTRAL STATION

The Fort Worth Transportation Authority weaves Fort Worth's rich history with the community's vibrant future. Restored for use here are

six electric lamps that once adorned the Fort Worth Public Library building, constructed in 1939 and demolished in 1990. The

chandelier from the Library's stair tower is now in the center of the Central Station's clock tower. Five other Art Deco fixtures light up the

second floor.

V.I.F.

APPROX.9 3/4"

V.I.F.

APPROX.9 3/4"

V.I

.F.

AP

PR

OX

.5

1/2

"

V.I

.F.

AP

PR

OX

.1

0 3

/4"

SIGN TYPE C11

SIGN TYPE C12

VERIFY AND MATCH SIZE AND MATERIAL OF EXISTING DEDICATION PLAQUES. MATCH TEXT SIZE WITH TEXT CONTENT AS SHOWN.

Phone

SIGN TYPE C07 (4 EA)

10.14.19.15

10.14.19.20

REMOVE EXISTING SIGNAGE PANEL. REPLACE WITH NEW PANEL. GRAPHICS AS SHOWN.FORT WORTH

CENTRAL STATION

10.14.19.10

05.00.00.03

05.00.00.04

8" EQ 4' - 4 1/2" EQ 8"

4"

EQ

4 1

/2"

3"

4 1

/2"

EQ

4"

EXIST. LIMESTONE SIGN FACE

2 1/2"

2 1

/2"

SIGN TYPE C06 (1 EA)

SHEET No.

ARCHITECTS

1203 DRAGON STREET

DALLAS, TEXAS 75207

214.293.5227

WWW.MANNINGARCHITECTS.COM

ARCHITECTURE I INTERIORS I PLANNING

MANNING

DWG No. REV

REV DATE DESCRIPTION BY DES APRCHKTBAE REGISTRATION No. 19484

TBPE FIRM REGISTRATION No. F-3557TBPLS FIRM REGISTRATION No. 100383

500 WEST SEVENTH STREET

FORT WORTH, TEXAS 76102

817.339.8950

WWW.TRANSYSTEMS.COM

TRINITY METRO

SCALE

DRAWN

DESIGNED

CHECKED

IN CHARGE

DATE

TRINITY METROFACILITIES UPGRADE PROJECT

TEXAS & PACIFIC STATION PYLONSIGN - ELEVATION

A210.1

KEYNOTES

05.00.00.03 1/8" STAINLESS STEEL SIGN FACE. BRUSHED FINISH

05.00.00.04 1 1/2" CYLINDER STAINLESS STEEL STAND-OFF. ANCHOR INTOEXISTING LIMESTONE

09.91.00.08 PAINT, LOW-SHEEN EGGSHELL, COLOR TO MATCH PANTONEPROCESS BLACK

10.14.19.10 DIMENSIONAL LETTERS - CUT VINYL, PROXIMA NOVASEMI-BOLD, 3M SCREEN PRINTING UV INK SERIES 9800 ORAPPROVED EQUAL, SIZE AS SHOWN. COLOR TO MATCHPANTONE PMS 281C

10.14.19.11 DIMENSIONAL LETTERS - CUT VINYL, AVANTE GARDE GOTHICBOLD, 3M SCREEN PRINTING UV INK SERIES 9800 OR APPROVEDEQUAL, SIZE AS SHOWN. COLOR TO MATCH PANTONE PMS 281C

10.14.19.12 DIMENSIONAL LETTERS - CUT VINYL, AVANTE GARDE GOTHICBOOK, 3M SCREEN PRINTING UV INK SERIES 9800 ORAPPROVED EQUAL, SIZE AS SHOWN. COLOR TO MATCHPANTONE PMS 430C

10.14.19.13 DIMENSIONAL LETTERS - CUT VINYL, AVANTE GARDE GOTHICBOOK OBLIQUE, 3M SCREEN PRINTING UV INK SERIES 9800 ORAPPROVED EQUAL, SIZE AS SHOWN. COLOR TO MATCHPANTONE PMS 430C

10.14.19.15 PRINT LOGO DECAL - CUT VINYL, 3M SCREEN PRINTING UV INKSERIES 9800 OR APPROVED EQUAL, SIZE AS SHOWN. COLOR TOMATCH PANTONE PMS 281C

10.14.19.16 PRINT LOGO DECAL - CUT VINYL, 3M SCREEN PRINTING UV INKSERIES 9800 OR APPROVED EQUAL, SIZE AS SHOWN. COLOR TOMATCH PANTONE PMS 185C

10.14.19.17 PRINT LOGO DECAL - CUT VINYL, 3M SCREEN PRINTING UV INKSERIES 9800 OR APPROVED EQUAL, SIZE AS SHOWN. COLOR TOMATCH PANTONE PMS 116C

10.14.19.20 DIMENSIONAL LETTERS - CUT VINYL, PROXIMA NOVASEMI-BOLD, 3M SCREEN PRINTING UV INK SERIES 9800 ORAPPROVED EQUAL, SIZE AS SHOWN. COLOR TO MATCHPANTONE PMS 430C

AS SHOWN

CK

CK

CC

RM

3/4" = 1'-0"A210.1

01 T&P MONUMENT SIGN ELEVATION3" = 1'-0"A210.1

02 CENTRAL STATION DEDICATION PLAQUES

1 1/2" = 1'-0"A210.1

03 CENTRAL STATION -PHONE BOX1/2" = 1'-0"A210.1

04 CENTRAL STATION - TOWER SIGN

1

D

2

W

AR

M

APRTBAE REGISTRATION No. 19484

APRTBAE REGISTRATION No. 19484

August 27, 2019

Page 9: TRINITY METRO / TEXRAIL SIGNAGE PROJECT INVITATION …...10.14.19.25 update pay phone logo. ref: 02/a201. 10.14.19.26 remove existing door signage (6 locations), clean adhesive from

TRINITY METRO

2' -

11

3/4

"

1' -

0"

SIGN TYPE M01

09.91.00.06

09.91.00.1014' - 0"

SHEET No.

ARCHITECTS

1203 DRAGON STREET

DALLAS, TEXAS 75207

214.293.5227

WWW.MANNINGARCHITECTS.COM

ARCHITECTURE I INTERIORS I PLANNING

MANNING

DWG No. REV

REV DATE DESCRIPTION BY DES APRCHKTBAE REGISTRATION No. 19484

TBPE FIRM REGISTRATION No. F-3557

TBPLS FIRM REGISTRATION No. 100383

500 WEST SEVENTH STREET

FORT WORTH, TEXAS 76102

817.339.8950

WWW.TRANSYSTEMS.COM

TRINITY METRO

SCALE

DRAWN

DESIGNED

CHECKED

IN CHARGE

DATE

TRINITY METRO

FACILITIES UPGRADE PROJECT

TEXRAIL EQUIPMENT MAINTENANCE

FACILITY - ELEVATION

A211

3/32" = 1'-0"A211

01 TEXRAIL EQUIPMENT MAINTENANCE FACILITY - NORTH

KEYNOTES

09.91.00.06 PAINT, LOW-SHEEN EGGSHELL, COLOR TO MATCH PANTONE

PMS 281C

09.91.00.10 PAINT, LOW-SHEEN EGGSHELL, COLOR TO MATCH PANTONE

PMS 430C

3/32" = 1'-0"

CK

CK

CC

RM

CONTRACTOR TO

PROVIDE FULL SIZE

MOCK UP FOR

APPROVAL

TEXRAIL SIGNAGE PROJECT

APRTBAE REGISTRATION No. 19484

August 27, 2019