Maximum performanceOur cables are highly suited for the most demanding installations. Just take our flagship KOKA 110 coaxial cable as an example, which offers:
� The highest levels of interference protection
� Crystal clear HD & 4K TV images
� Up- and downstream data transmission
� Exceptional build quality and durability
� Safety in case of fire
Maximum safety – EN50575 compliant All TRIAX cables are fully tested and classified according to the EN50575 Construction Products Regulation, in force from 1 July 2017, so they:
� Meet the highest demands for safety in case of fire
� Are safe and suitable for all building projects across the EU and the world
TRIAX® CablesFutureproof. Fire safe.
Superior quality cables for the most demanding networks
TRIAX cables are designed to meet the standards of today and the network demands of tomorrow.Specially crafted and highly shielded to minimise interference, each one has been meticulously updated and rigorously tested to conform to the new EN50575 fire safety standard.
Protected
LTECPREN50575Compliant
triax.com
May
201
7Copyright © 2017 TRIAX. All rights reserved. The TRIAX Logo and TRIAX, TRIAX Multimedia
are registered trademarks or trademarks of the TRIAX Company or its affiliates.
All specifications in this brochure are subject to change without further notice.
TRIAX fire safe cablesCE marked, meeting the new EU fire standard
About Construction Products Regulation (EU) No 305/2011This regulation, coming into force for cables from 1 July 2017, identifies a number of basic requirements to be met by products, including cables, used in construction works. One of these requirements, EN50575:2014+A1:2016, is ‘safety in case of fire’. All cables sold within the EU for the construction market must be CE marked, to show that they have been tested and classified accordingly and therefore meet these mandatory standards.
EN50575 defines a number of classes – Aca, B1ca, B2ca, Cca, Dca, Eca and Fca – which specify how a cable reacts to fire, based on heat release and the spread of flames. The classes and respective test methods are presented in the following table:
CE markings for cablesIn order to obtain the mandatory CE mark for cables, manufacturers must draw up a Declaration of Performance (DoP). This must be made available in the language of each EU country where the product is to be sold, and contain specific information such as product identification, its intended use, and its declared performance.
The DoP – and consequently the CE mark – can only be issued once the product has been thoroughly and independently tested by a ‘notified body,’ i.e. an entity that has been accredited by an EU Member State to make the required assessments.
TRIAX cables: fully tested and CE marked We are happy to assure our customers that all TRIAX cables are now stamped with the CE mark, and the necessary DoPs are available for each product line. The cables have been variously classified B2ca, Cca & Eca, meeting all statutory demands, and satisfying the recommendations of ZVEI, the German Electrical and Electronic Manufacturers’ Association.
Euro-Class Contribution to a fire
AVCP System
Additional test Assessment and certification process
Not applicable to Data cables
A No contribution
1+ SmokeAcidityDroplet
Notified body issues attestation of conformity after: • Initial type test• Factory audit• Biannual production inspection• Annual audit test on samples taken
from warehouse
B1 Minimum contribution
Data Cables for indoor application
B2 Very limited contribution
C Limited contribution
D Average contribution3
Notified body issues attestation of conformity after:• Initial type testE High contribution –
Not acceptable in the buildings F Undetermined fire
properties 4 – Self-declaration by Manufacturer