trial for compare the effect on magnetic ring setup around the gas regulator tube
TRANSCRIPT
-
7/31/2019 Trial for Compare the Effect on Magnetic Ring Setup Around the Gas Regulator Tube
1/2
0.00
0.05
0.10
0.15
0.20
0.25
0.30
0.35
0.40
0.45
0.00 1.00 2.00 3.00 4.00 5.00 6.00 7.00
Gas Consuption
(kg)
Trial No.
Gas Consumption of
Dryer R8
without magnets
with magnets
Trial for Compare the Effect on Magnetic Ring Setup around the Gas Regulator Tube
Observations
Gas consumption appears to be significantly high in the first trial performed with the magnets. This is reasonablesince the dryer is at room temperature.(This trial was taken as neglected one)
Above observation wasnt appear in the trial performed without magnets because dryer was in use before thetrial begins.
Calculation
With magnetic ring setup (Neglecting the first trial and consider the other five trials),
Without magnetic ring setup,
Thus approximately 18% of gas consumption increment has been observed.
Approximate gas consumption difference between the first trial and the other trials
%
Trial
No.
Gas Consumption
(kg) [with magnets]
Gas Consumption (kg)
[without magnets]
1.00 0.40 -
2.00 0.20 0.20
3.00 0.25 0.254.00 0.30 0.20
5.00 0.35 0.20
6.00 0.20 0.25
-
7/31/2019 Trial for Compare the Effect on Magnetic Ring Setup Around the Gas Regulator Tube
2/2
Conclusions
No significant gas saving though the magnetic rings setting up around the gas regulator tube. Fluctuations of the gas consumption over the trial No. is reasonable because there are different No. of gas firing
times present within a cycle.
Gas consumption seems to be significantly heavy when using a dryer which gets cooled to the roomtemperature. Thermal conductivity of the metal drum is too higher than its value of the gloves. Thus Hot air flow
first transfers its heat to the drum before heating the gloves.
About 54% of gas saving can be obtain if choose a dryer to run next cycle immediately after the previous cycle
finished.
Different workers follow different methods for applying Deo liquid and inserting the towels. Some areperforming both task before the cycle starts
method1and others perform it while the cycle is running
method2
(opening the door when 8 min pass after cycle starts).Opening the door while the cycle is running yields to
escape some of the heat inside the dryer to the surrounding. Applying Deo liquid and towels before the cycle
starts yields low heating rate for the dryer than the other method, thus increases the gas firing time.
(Method 1 was utilizes by the dryer workers while performing the trial with the magnetic ring setup and the
other method was in practice while performing the trial without magnetic ring setup)
Thus the conditions present while performing the trial differs from each other though the regulator valve
position and other conditions maintained as same. This may be the cause for obtaining negative results.
Trial Performed & Report Prepared by,
Ranil Fernando
Engineering Trainee,
Venigros Ltd.