trans. melsec a para q (ingles).pdf

36
 Mitsubishi Programmable Controllers MELSEC-A/QnA Series Transition Guide Aug. 2012 Edition

Upload: diasalexandre9739

Post on 04-Nov-2015

218 views

Category:

Documents


0 download

TRANSCRIPT

  • Mitsubishi Programmable ControllersMELSEC-A/QnA Series Transition Guide

    Aug. 2012 Edition

  • 1 2

    From the MELSEC-A/QnA SeriesThe MELSEC-Q Series

    Network

    P.4

    P.7

    P.11

    P.13

    P.15

    Reuse existing 32-point I/O with Q SeriesQ Series large type base unit/Q Series large type I/O module

    Upgrade A Series to Q Series while reusing existing wiringUpgrade tool

    Reuse existing A Series I/O with Q SeriesQA extension base unitQA conversion adapter module

    Convert existing A Series programsA/QnA Q conversion support tool

    Related informationTechnical bulletinsReplacement handbooks

    MELSOFT

    Redundantsystem

    NetworkP.19

    P.22Replace Q4ARCPU redundant systems with Q SeriesQ Series redundant system

    Q Series MELSECNET(), MELSECNET/B compatibilityAnS (small type) local station dedicated moduleMELSECNET()-MELSECNET/10 gateway setMELSECNET/10 network module (Production continues)

    P.17Use modules that have a high rated input current and are compatible with proximity sensor inputs24 V DC input modules with a rated input current of 6 mA

    P.17Avoid program changes when replacing I/O combined modules AH42 and A0J2(H)CPUI/O combined module with 64 occupied poitns

    P.17Replace high-speed counter modules without restrains from specifications of the connected external devicesDedicated replacement high-speed counter modules

    P.17Replace the positioning module while keeping the existing external devicesPositioning module

    P.18Use existing MELSECNET/B twisted pair cables to construct MELSECNET/H network systemsMELSECNET/H network module (twisted bus type)

    Mitsubishi Electric offers a carefully engineered combination of hardware, software, and support designed to allow you to upgrade legacy A and QnA Series controller systems to the current MELSEC-Q Series with minimum disruption to your plant operations.

  • 1 2

    From the MELSEC-A/QnA SeriesThe MELSEC-Q Series

    Network

    P.4

    P.7

    P.11

    P.13

    P.15

    Reuse existing 32-point I/O with Q SeriesQ Series large type base unit/Q Series large type I/O module

    Upgrade A Series to Q Series while reusing existing wiringUpgrade tool

    Reuse existing A Series I/O with Q SeriesQA extension base unitQA conversion adapter module

    Convert existing A Series programsA/QnA Q conversion support tool

    Related informationTechnical bulletinsReplacement handbooks

    MELSOFT

    Redundantsystem

    NetworkP.19

    P.22Replace Q4ARCPU redundant systems with Q SeriesQ Series redundant system

    Q Series MELSECNET(), MELSECNET/B compatibilityAnS (small type) local station dedicated moduleMELSECNET()-MELSECNET/10 gateway setMELSECNET/10 network module (Production continues)

    P.17Use modules that have a high rated input current and are compatible with proximity sensor inputs24 V DC input modules with a rated input current of 6 mA

    P.17Avoid program changes when replacing I/O combined modules AH42 and A0J2(H)CPUI/O combined module with 64 occupied poitns

    P.17Replace high-speed counter modules without restrains from specifications of the connected external devicesDedicated replacement high-speed counter modules

    P.17Replace the positioning module while keeping the existing external devicesPositioning module

    P.18Use existing MELSECNET/B twisted pair cables to construct MELSECNET/H network systemsMELSECNET/H network module (twisted bus type)

    Mitsubishi Electric offers a carefully engineered combination of hardware, software, and support designed to allow you to upgrade legacy A and QnA Series controller systems to the current MELSEC-Q Series with minimum disruption to your plant operations.

  • 3 4

    Large type A/QnA Series A/QnA (large type) CPU module I/O module

    Special function module

    Data link module (MELSECNET(), MELSECNET/B module, etc.)

    PC interface boardMELSECNET(), MELSECNET(), MELSECNET/B MELSECNET/B interface board

    A2C SeriesA2C CPU module A2C I/O module

    Special function module etc.

    A0J2(H) SeriesA0J2H CPU module Power supply module

    I/O module

    Special function module etc.

    1 Production of AnS Series master/local station data link modules (A1SJ71AP21, A1SJ71AR21, and A1SJ71AT21B) will be continued.

    Please check the Technical Bulletin "Repair acceptance of discontinued models (FA-A-0049)" for the repair acceptance period of the above discontinued products.

    Small type AnS SeriesMELSECNET(), Remote I/O moduleMELSECNET/B1 MELSECNET/MINI-S3 AnS (small type) master module I/O module

    Date of discontinuation Technical bulletin

    End of Sep. 2006

    End of Sep. 2008

    End of Sep. 2008

    T99-0050T99-0070

    T99-0070

    End of Sep. 2008 T99-0049

    End of Sep. 2008 T99-0049

    End of Sep. 2008

    End of Sep. 2008

    T99-0070

    T99-0070

    End of Sep. 2008

    End of Sep. 2008

    End of Sep. 2008

    End of Sep. 2008

    T99-0069

    T99-0069

    T99-0069

    T99-0069

    End of Sep. 2006

    End of Sep. 2006

    End of Sep. 2006

    End of Sep. 2006

    T99-0050

    T99-0050

    T99-0050

    T99-0050

    At-a-glance technical overviewsAt-a-glance technical overviews

    Modification

    CC-Link

    Support

    Support

    P.27

    P.25

    P.28

    P.34Support capabilitiesGlobal FA centers

    Product listList of products used for upgradeModels in continuous production Discontinued productsService availability period

    Replace MELSECNET/MINI-S3 with CC-LinkA2C shape CC-Link remote I/O moduleMELSECNET/MINI-S3 I/O module wiring conversion adapter

    Replace A Series modules with AnS equivalentsA-A1S module conversion adapter

    Technical Bulletins

    P.23Replace A0J2(H) systems with Q SeriesA0J2 renewal tool

  • 3 4

    Large type A/QnA Series A/QnA (large type) CPU module I/O module

    Special function module

    Data link module (MELSECNET(), MELSECNET/B module, etc.)

    PC interface boardMELSECNET(), MELSECNET(), MELSECNET/B MELSECNET/B interface board

    A2C SeriesA2C CPU module A2C I/O module

    Special function module etc.

    A0J2(H) SeriesA0J2H CPU module Power supply module

    I/O module

    Special function module etc.

    1 Production of AnS Series master/local station data link modules (A1SJ71AP21, A1SJ71AR21, and A1SJ71AT21B) will be continued.

    Please check the Technical Bulletin "Repair acceptance of discontinued models (FA-A-0049)" for the repair acceptance period of the above discontinued products.

    Small type AnS SeriesMELSECNET(), Remote I/O moduleMELSECNET/B1 MELSECNET/MINI-S3 AnS (small type) master module I/O module

    Date of discontinuation Technical bulletin

    End of Sep. 2006

    End of Sep. 2008

    End of Sep. 2008

    T99-0050T99-0070

    T99-0070

    End of Sep. 2008 T99-0049

    End of Sep. 2008 T99-0049

    End of Sep. 2008

    End of Sep. 2008

    T99-0070

    T99-0070

    End of Sep. 2008

    End of Sep. 2008

    End of Sep. 2008

    End of Sep. 2008

    T99-0069

    T99-0069

    T99-0069

    T99-0069

    End of Sep. 2006

    End of Sep. 2006

    End of Sep. 2006

    End of Sep. 2006

    T99-0050

    T99-0050

    T99-0050

    T99-0050

    At-a-glance technical overviewsAt-a-glance technical overviews

    Modification

    CC-Link

    Support

    Support

    P.27

    P.25

    P.28

    P.34Support capabilitiesGlobal FA centers

    Product listList of products used for upgradeModels in continuous production Discontinued productsService availability period

    Replace MELSECNET/MINI-S3 with CC-LinkA2C shape CC-Link remote I/O moduleMELSECNET/MINI-S3 I/O module wiring conversion adapter

    Replace A Series modules with AnS equivalentsA-A1S module conversion adapter

    Technical Bulletins

    P.23Replace A0J2(H) systems with Q SeriesA0J2 renewal tool

  • 5 6

    Fundamentals

    Intelligent Function Modules

    Network Modules

    Communication Modules

    Transition from MELSEC-A/QnA (Large Type) Series to Q Series HandbookL(NA)08043ENG

    L(NA)08046ENG

    L(NA)08048ENG

    L(NA)08050ENG

    Transition from MELSEC-A0J2H Series to Q Series HandbookL(NA)08060ENG

    Transition from MELSECNET/MINI-S3, A2C (I/O) to CC-Link HandbookL(NA)08061ENG

    Transition from MELSEC-I/OLINK to CC-Link/LT HandbookL(NA)08062ENG

    MELSEC-A/QnA Series Transition ExamplesL(NA)08121ENG

    Transition from MELSEC-A/QnA (Large Type) Series toAnS/Q2AS (Small Type) Series Handbook

    L(NA)08064ENG

    Transition of CPUs in MELSEC Redundant System HandbookTransition from Q4ARCPU to QnPRHCPU

    L(NA)08117ENG

    In-depth technical documentation resourcesIn-depth technical documentation resources

    For the products shown in handbooks for transition, catalogues, and transition examples, refer to the manuals for the relevant products and check the detailed specifications, precautions for use, and restrictions before replacement.For the products manufactured by Mitsubishi Electric Engineering Co., Ltd., Mitsubishi Electric System & Service Co., Ltd., and other companies, refer to the catalogue for each product and check the detailed specifications, precautions for use, and restrictions before use.The manuals and catalogues for our products, products manufactured by Mitsubishi Electric Engineering Co., Ltd., and Mitsubishi Electric System & Service Co., Ltd., are shown in Appendix of each handbook for transtion.

    Products shown in this handbook are subject to change without notice.

    MEMO

  • 5 6

    Fundamentals

    Intelligent Function Modules

    Network Modules

    Communication Modules

    Transition from MELSEC-A/QnA (Large Type) Series to Q Series HandbookL(NA)08043ENG

    L(NA)08046ENG

    L(NA)08048ENG

    L(NA)08050ENG

    Transition from MELSEC-A0J2H Series to Q Series HandbookL(NA)08060ENG

    Transition from MELSECNET/MINI-S3, A2C (I/O) to CC-Link HandbookL(NA)08061ENG

    Transition from MELSEC-I/OLINK to CC-Link/LT HandbookL(NA)08062ENG

    MELSEC-A/QnA Series Transition ExamplesL(NA)08121ENG

    Transition from MELSEC-A/QnA (Large Type) Series toAnS/Q2AS (Small Type) Series Handbook

    L(NA)08064ENG

    Transition of CPUs in MELSEC Redundant System HandbookTransition from Q4ARCPU to QnPRHCPU

    L(NA)08117ENG

    In-depth technical documentation resourcesIn-depth technical documentation resources

    For the products shown in handbooks for transition, catalogues, and transition examples, refer to the manuals for the relevant products and check the detailed specifications, precautions for use, and restrictions before replacement.For the products manufactured by Mitsubishi Electric Engineering Co., Ltd., Mitsubishi Electric System & Service Co., Ltd., and other companies, refer to the catalogue for each product and check the detailed specifications, precautions for use, and restrictions before use.The manuals and catalogues for our products, products manufactured by Mitsubishi Electric Engineering Co., Ltd., and Mitsubishi Electric System & Service Co., Ltd., are shown in Appendix of each handbook for transtion.

    Products shown in this handbook are subject to change without notice.

    MEMO

  • 8Minimize program conversion eorts by using GX Developer'sPLC Type Change function and the Q Conversion Support Tool.

    Automatic Program Conversion:GX Developer & Q Conversion Support Tool

    The Q Conversion Support Tool boosts productivity by avoiding time spent consultingmanuals for guidance on nishing program conversions.

    Image of dierences between the two programs

    A/QnA program

    Original project

    Q program

    Converted projectGX Developer

    7

    Convert A/QnA programs to Q programswith GX Developer's PLC Type Change function.

    Change to Q beforehand

    PLC type change

    A/QnA Q conversion support tool

    Dierences between the two programs

    1Point

    No need to manually compare the existing program with the converted program! 2

    Point

    A list of unconverted instructions and devices is displayed.

    Information on recommended products for unconvertible special function modules is displayed.

    HTML conversionguidance le

    Dierences between the two programs andguidance on how to complete the

    conversion are displayed.

    Output

    Dierencesbetween two programs

    Enter the conguration information on the existing A/QnA special function modules.

    Note 1: This support tool applies to ladder programs only.Note 2: Conversion from AnS/Q2AS(H) programs to Q programs is also supported.Note 3: The A/QnA Q Conversion Support Tool does not support Universal model (QnU) CPUs. To convert a CPU to a

    Universal model QCPU, perform the following procedure./ Using GX Developer, change the PLC type of the original project to a PLC type which is supported by the A/QnA Q Conversion Support Tool. (Converted project 1)

    0 Again using GX Developer, change the PLC type of the original project to Universal model QCPU. (Converted project 2)1 Open the original project and the converted project 1 in the A/QnA Q Conversion Support Tool.2 Reect the output result from step 3 to the converted project 2.

    / /

    0

    11

    Can be modied directly. Prevents mistakes and improves eciency.

    /Statement of unconverted devicesThe original device and the converted device are displayed as shown below. The devices contained in the circuit block are displayed one line at a time.(E.g.) #00001 ANI M9201 SM1255 ("#00001" is a search keyword in the HTML conversion guidance le.)

    0Statement of unconverted instructions%The original instruction and the converted instruction are displayed as shown below. The instructions contained in the circuit block are displayed one line at a time.(E.g.) 00001 LRDP K3 D10 D100 K3 OUT SM1255 ("%00001" is a search keyword in the HTML conversion guidance le.)

    1Statement of special function module processes!For the special function module instructions (FROM, DFRO, TO, DTO and instructions using X/Y devices), a message requesting review is displayed.(E.g.) !00001 Specal Function Module Process! Refer to ReviewInformation ("!00001" is a search keyword in the HTML conversion guidance le.)

    Soon to be supported by Universal model QCPU (QnU)Soon to be supported by

    Universal model QCPU (QnU)

  • 8Minimize program conversion eorts by using GX Developer'sPLC Type Change function and the Q Conversion Support Tool.

    Automatic Program Conversion:GX Developer & Q Conversion Support Tool

    The Q Conversion Support Tool boosts productivity by avoiding time spent consultingmanuals for guidance on nishing program conversions.

    Image of dierences between the two programs

    A/QnA program

    Original project

    Q program

    Converted projectGX Developer

    7

    Convert A/QnA programs to Q programswith GX Developer's PLC Type Change function.

    Change to Q beforehand

    PLC type change

    A/QnA Q conversion support tool

    Dierences between the two programs

    1Point

    No need to manually compare the existing program with the converted program! 2

    Point

    A list of unconverted instructions and devices is displayed.Information on recommended products for unconvertible special function modules is displayed.

    HTML conversionguidance le

    Dierences between the two programs andguidance on how to complete the

    conversion are displayed.

    Output

    Dierencesbetween two programs

    Enter the conguration information on the existing A/QnA special function modules.

    Note 1: This support tool applies to ladder programs only.Note 2: Conversion from AnS/Q2AS(H) programs to Q programs is also supported.Note 3: The A/QnA Q Conversion Support Tool does not support Universal model (QnU) CPUs. To convert a CPU to a

    Universal model QCPU, perform the following procedure./ Using GX Developer, change the PLC type of the original project to a PLC type which is supported by the A/QnA Q Conversion Support Tool. (Converted project 1)

    0 Again using GX Developer, change the PLC type of the original project to Universal model QCPU. (Converted project 2)1 Open the original project and the converted project 1 in the A/QnA Q Conversion Support Tool.2 Reect the output result from step 3 to the converted project 2.

    / /

    0

    11

    Can be modied directly. Prevents mistakes and improves eciency.

    /Statement of unconverted devicesThe original device and the converted device are displayed as shown below. The devices contained in the circuit block are displayed one line at a time.

    (E.g.) #00001 ANI M9201 SM1255 ("#00001" is a search keyword in the HTML conversion guidance le.)

    0Statement of unconverted instructions%The original instruction and the converted instruction are displayed as shown below. The instructions contained in the circuit block are displayed one line at a time.

    (E.g.) 00001 LRDP K3 D10 D100 K3 OUT SM1255 ("%00001" is a search keyword in the HTML conversion guidance le.)

    1Statement of special function module processes!For the special function module instructions (FROM, DFRO, TO, DTO and instructions using X/Y devices), a message requesting review is displayed.

    (E.g.) !00001 Specal Function Module Process! Refer to ReviewInformation ("!00001" is a search keyword in the HTML conversion guidance le.)

    Soon to be supported by Universal model QCPU (QnU)Soon to be supported by

    Universal model QCPU (QnU)

  • Automatic Program Conversion:GX Developer & Q Conversion Support Tool

    (Example 1) Special function module processes which need to be reviewed

    Click the recommended module namenext to "The recommended modulesthat can be replaced."

    Click "By special function module name" in the"Programs for special function modules necessaryin review" row.

    109

    Detailed information is displayed hierarchically in your web browser. Information on the dierences between the two programs and the conversion guidance le are linked together.

    HTML conversion guidance leEasy comparison of performance specications before and after replacement.

    (Example 2) Special relays and registers which are not converted in the Q program

    Click "Device no. order" in the "Special relay/special register not been converted in PLC type changing" row.

    Details of unconverted special relays and registers can be displayed, improving conversioneciency.

  • Automatic Program Conversion:GX Developer & Q Conversion Support Tool

    (Example 1) Special function module processes which need to be reviewed

    Click the recommended module namenext to "The recommended modulesthat can be replaced."

    Click "By special function module name" in the"Programs for special function modules necessaryin review" row.

    109

    Detailed information is displayed hierarchically in your web browser. Information on the dierences between the two programs and the conversion guidance le are linked together.

    HTML conversion guidance leEasy comparison of performance specications before and after replacement.

    (Example 2) Special relays and registers which are not converted in the Q program

    Click "Device no. order" in the "Special relay/special register not been converted in PLC type changing" row.

    Details of unconverted special relays and registers can be displayed, improving conversioneciency.

  • 1211

    Reduce conversion eort by using the same I/O addressingWhen reusing existing modules with a Q Series CPU, it is not required to change the I/O number of the existing modules. For new module(s) on the main base unit, assign a number after the existing modules in the I/O assignment settings. This can greatly reduce the program modication time.

    Replacedmodules (A to Q)

    QA6B or A6B(with QA conversion adapter module)

    Q35B 0

    0 1 2 3 4

    1 2 3 4

    5 6 7 8 9

    Newly addedmodules

    Note: Assign the I/O numbers in the following order: Q Series to A Series or A Series to Q Series. When the order is mixed (i.e., Q Series A Series Q Series), an error will occur in the CPU.

    Example of I/O assignment

    TypeModel

    0

    1

    2

    3

    4

    Intelli.

    Intelli.

    Input

    Input

    Output

    AX41

    AY41

    AX41

    QJ61BT11N

    QJ71LP21-25

    QX41

    QX41

    QY41P

    100

    120

    140

    160

    180

    5

    6

    7

    8

    9

    32 points

    32 points

    32 points

    32 points

    32 points

    00

    20

    40

    60

    80

    Address TypeModel Point Address

    Replace CPU to Q Series CPU while using existing A series modules.Use existing A Series modules when upgrading to QCPU.

    QA1S65B/QA1S68B Extension Base Unit

    For Large Type A/QnA Series

    QA Extension Base Unit ( )

    Remove the QA extension base unit (QA65B/QA68B) when all modules have been replaced with Q Series equivalents.

    Existing large type A Series

    Q Series

    Q Seriesextension cable

    Q Series

    Entire replacementwith the Q Series

    Existing large type A power supply,I/O modules, and other modules can beutilized; wiring is left as it is.

    Step 2Step 1

    Gradual transition from large type A Series to Q Series (Q mode).Construct a system that is controlled by the new Q Series CPU (Q mode) while keeping the existing large type A Series modules mounted to a QA6B extension base unit. The A Series modules can gradually be replaced to fully establish a Q Series system.

    It is recommended to use QA6B extension base units to gradually upgrade from A Series system to Q Series system while using the assets of large type A series system. (The QA6B extension base units are compatible with High Performance Model QCPUs only. Basic Model QCPUs, Process CPUs, Redundant CPUs, Safety CPUs,Universal Model QCPUs, and Remote I/O Stations are not compatible.)Please refer to the "QA65B/QA68B Extension Base Unit User's Manual (IB(NA)-0800158)" for details of modules that can be mounted on the QA6B extension base units.

    The small type AnS/Q2AS Series modules can also be used by connecting as a QCPU extension base.These extension base units can be used with QA65B and QA68B.

    QA65BQA68B

    Use existing A/QnA extension base units when upgrading to QCPU.

    Mount a QA conversion adapter module to use existing A Series extension base units with a Q Series CPU.

    The QA6ADP adapter cannot be connected to a QA1S extension base unit, which is used to mount small type AnS/Q2AS Series modules.The QA6ADP adapter is compatible with High Performance Model QCPUs only. Basic Model QCPUs, Process CPUs, Redundant CPUs, Safety CPUs, Universal Model QCPUs, and Remote I/O Stations are not compatible.

    Modules which can be mounted on the extension base unit (A6B) are the same as when QA6B is used.An adapter module mounting bracket is required to mount the QA6ADP adapter. Follow the instructions in the user's manual when mounting.When an AC input module is mounted on the "A5B" extension base unit (without power supply) using the QA6ADP, either the "A6B with QA6ADP" or "QA6B" extension base unit (with power supply) is required in the system.

    Notes

    Replace the A Series CPUwith a Q Series CPU.

    Replace the main baseunit (A3B) with the extensionbase unit (QA6B) andreuse existing modules.

    Mount the QA conversionadapter module (QA6ADP) on theextension base unit (A6B).

    Q Seriesextension cable

    Q Seriesextension cable

    Large type A Seriesextension cable

    A3NCPU

    AX41

    AY41

    Q06HCPU

    QJ61BT11N

    QJ71LP21-25

    QX41

    AX41

    AY41

    Empty

    Empty

    AX41

    QX41

    QY41P

    AJ61BT11

    AJ71LP21

    AX41

    Replace modules which cannot be mounted with Q Series modules.

    QA Conversion Adapter Module (QA6ADP)

    Mainbaseunit

    Extensionbaseunit

    32 points

    32 points

    32 points

    32 points

    32 points

    Point

    Input

    Output

    Empty

    Empty

    Input

    QA6ADP

    QA extension base(QA65B/QA68B)

  • 1211

    Reduce conversion eort by using the same I/O addressingWhen reusing existing modules with a Q Series CPU, it is not required to change the I/O number of the existing modules. For new module(s) on the main base unit, assign a number after the existing modules in the I/O assignment settings. This can greatly reduce the program modication time.

    Replacedmodules (A to Q)

    QA6B or A6B(with QA conversion adapter module)

    Q35B 0

    0 1 2 3 4

    1 2 3 4

    5 6 7 8 9

    Newly addedmodules

    Note: Assign the I/O numbers in the following order: Q Series to A Series or A Series to Q Series. When the order is mixed (i.e., Q Series A Series Q Series), an error will occur in the CPU.

    Example of I/O assignment

    TypeModel

    0

    1

    2

    3

    4

    Intelli.

    Intelli.

    Input

    Input

    Output

    AX41

    AY41

    AX41

    QJ61BT11N

    QJ71LP21-25

    QX41

    QX41

    QY41P

    100

    120

    140

    160

    180

    5

    6

    7

    8

    9

    32 points

    32 points

    32 points

    32 points

    32 points

    00

    20

    40

    60

    80

    Address TypeModel Point Address

    Replace CPU to Q Series CPU while using existing A series modules.Use existing A Series modules when upgrading to QCPU.

    QA1S65B/QA1S68B Extension Base Unit

    For Large Type A/QnA Series

    QA Extension Base Unit ( )

    Remove the QA extension base unit (QA65B/QA68B) when all modules have been replaced with Q Series equivalents.

    Existing large type A Series

    Q Series

    Q Seriesextension cable

    Q Series

    Entire replacementwith the Q Series

    Existing large type A power supply,I/O modules, and other modules can beutilized; wiring is left as it is.

    Step 2Step 1

    Gradual transition from large type A Series to Q Series (Q mode).Construct a system that is controlled by the new Q Series CPU (Q mode) while keeping the existing large type A Series modules mounted to a QA6B extension base unit. The A Series modules can gradually be replaced to fully establish a Q Series system.

    It is recommended to use QA6B extension base units to gradually upgrade from A Series system to Q Series system while using the assets of large type A series system. (The QA6B extension base units are compatible with High Performance Model QCPUs only. Basic Model QCPUs, Process CPUs, Redundant CPUs, Safety CPUs,Universal Model QCPUs, and Remote I/O Stations are not compatible.)Please refer to the "QA65B/QA68B Extension Base Unit User's Manual (IB(NA)-0800158)" for details of modules that can be mounted on the QA6B extension base units.

    The small type AnS/Q2AS Series modules can also be used by connecting as a QCPU extension base.These extension base units can be used with QA65B and QA68B.

    QA65BQA68B

    Use existing A/QnA extension base units when upgrading to QCPU.

    Mount a QA conversion adapter module to use existing A Series extension base units with a Q Series CPU.

    The QA6ADP adapter cannot be connected to a QA1S extension base unit, which is used to mount small type AnS/Q2AS Series modules.The QA6ADP adapter is compatible with High Performance Model QCPUs only. Basic Model QCPUs, Process CPUs, Redundant CPUs, Safety CPUs, Universal Model QCPUs, and Remote I/O Stations are not compatible.

    Modules which can be mounted on the extension base unit (A6B) are the same as when QA6B is used.An adapter module mounting bracket is required to mount the QA6ADP adapter. Follow the instructions in the user's manual when mounting.When an AC input module is mounted on the "A5B" extension base unit (without power supply) using the QA6ADP, either the "A6B with QA6ADP" or "QA6B" extension base unit (with power supply) is required in the system.

    Notes

    Replace the A Series CPUwith a Q Series CPU.

    Replace the main baseunit (A3B) with the extensionbase unit (QA6B) andreuse existing modules.

    Mount the QA conversionadapter module (QA6ADP) on theextension base unit (A6B).

    Q Seriesextension cable

    Q Seriesextension cable

    Large type A Seriesextension cable

    A3NCPU

    AX41

    AY41

    Q06HCPU

    QJ61BT11N

    QJ71LP21-25

    QX41

    AX41

    AY41

    Empty

    Empty

    AX41

    QX41

    QY41P

    AJ61BT11

    AJ71LP21

    AX41

    Replace modules which cannot be mounted with Q Series modules.

    QA Conversion Adapter Module (QA6ADP)

    Mainbaseunit

    Extensionbaseunit

    32 points

    32 points

    32 points

    32 points

    32 points

    Point

    Input

    Output

    Empty

    Empty

    Input

    QA6ADP

    QA extension base(QA65B/QA68B)

  • 1413

    Permits Q Series upgrade with existing 32-point I/O wiring.

    Remove the wired terminal block from the existing I/O module.

    Remove the wired terminal block from the existing I/O module.

    Q Series large type blank cover (QG69L)(To mount a standard Q Series module on a large type base unit)

    Q Series module

    Q Series module

    Mount Q Series standard power supply and CPU modules.

    Mount directly.

    Mount directly.

    QX40

    LA

    FUSE

    0

    2

    4

    6

    1

    3

    5

    7

    L8

    A

    C

    E

    9

    B

    D

    F

    L8

    A

    C

    E

    9

    B

    D

    F

    QY23LTRIACAC100

    /240V

    0.6A

    LB

    0

    2

    4

    6

    1

    3

    5

    7

    1

    3

    5

    7

    9

    11

    13

    15

    17

    19

    21

    23

    25

    27

    29

    31

    33

    35

    37

    2

    4

    6

    8

    10

    12

    14

    16

    18

    20

    22

    24

    26

    28

    30

    32

    34

    36

    38

    QY23L

    A

    0

    2

    4

    6

    1

    3

    5

    7

    COM

    COM

    COM

    COM

    8

    A

    C

    E

    9

    B

    D

    F

    8

    A

    C

    E

    9

    B

    D

    F

    QX11LAC100

    V

    10mA

    B

    0

    2

    4

    6

    1

    3

    5

    7

    1

    3

    5

    7

    9

    11

    13

    15

    17

    19

    21

    23

    25

    27

    29

    31

    33

    35

    37

    2

    4

    6

    8

    10

    12

    14

    16

    18

    20

    22

    24

    26

    28

    30

    32

    34

    36

    38

    QX11L

    LA

    0

    2

    4

    6

    1

    3

    5

    7

    L8

    A

    C

    E

    9

    B

    D

    F

    L8

    A

    C

    E

    9

    B

    D

    F

    + -

    QY13LRELAY

    AC240V 2A

    DC24V

    2A

    LB

    0

    2

    4

    6

    1

    3

    5

    7

    1

    3

    5

    7

    9

    11

    13

    15

    17

    19

    21

    23

    25

    27

    29

    31

    33

    35

    37

    2

    4

    6

    8

    10

    12

    14

    16

    18

    20

    22

    24

    26

    28

    30

    32

    34

    36

    38

    QY13LQ12HC

    PU

    MODERUNERR.

    USERBAT.

    BOOT

    PULL

    USB

    RS-232

    Q62P

    POWER

    PULL

    QX40

    LA

    FUSE

    0

    2

    4

    6

    1

    3

    5

    7

    L8

    A

    C

    E

    9

    B

    D

    F

    L8

    A

    C

    E

    9

    B

    D

    F

    QY23LTRIACAC100

    /240V

    0.6A

    LB

    0

    2

    4

    6

    1

    3

    5

    7

    QY23L

    1

    3

    5

    7

    9

    11

    13

    15

    17

    19

    21

    23

    25

    27

    29

    31

    33

    35

    37

    2

    4

    6

    8

    10

    12

    14

    16

    18

    20

    22

    24

    26

    28

    30

    32

    34

    36

    38

    1

    3

    5

    7

    9

    11

    13

    15

    17

    19

    21

    23

    25

    27

    29

    31

    33

    35

    37

    2

    4

    6

    8

    10

    12

    14

    16

    18

    20

    22

    24

    26

    28

    30

    32

    34

    36

    38

    Through the use of an upgrade tool (manufactured by Mitsubishi Electric Engineering Co., LTD., refer to page 15), terminal block modules that are not compatible with the Q Series large type I/O modules can be mounted without rewiring. For compatibility of Q Series large type base unit and upgrade tool, refer to page 16.

    Notes

    Q Series large type base unit(includes base adapter)

    Q Series large typeI/O modules

    Q Series large type I/O module

    Upgrade tool (conversion adapter) manufactured by Mitsubishi Electric Engineering Co., Ltd.

    Q38BLQ35BL

    Q68BLQ65BLQ55BL

    QX11LQX21L QG69L

    QY11ALQY13LQY23LQY51PL

    Q Series Large Type Base Unit,I/O Module ( )

    Minimize wiring modications by reusing existing A Series 32-point I/O wiring.No need to make new mounting holes. The hole size and pitch of the Q Series large type base units are the same as those of large type A Series.

    ModelProduct name

    Main base unit

    Q38BL

    Extension base unit

    Q68BL

    8 slots, 1 power supply module required,Q Series large type I/O module mountable

    Q35BL5 slots, 1 power supply module required, Q Series large type I/O module mountable

    8 slots, 1 power supply module required, Q Series large type I/O module mountable

    Q65BL5 slots, 1 power supply module required, Q Series large type I/O module mountable

    Q55BL5 slots, power supply module not required,Q Series large type I/O module mountable

    Q Series large type base unit optionsOutline

    Model

    Output module

    Blank cover for mounting existing Q Series module on the Q Series large type base unit

    QX11L

    QY13L

    QY23L

    QG69L

    AX11

    Q Serieslarge typemodule

    ExistingA Seriesmodule

    AY13

    AY23

    N/A

    32 points; 100 to 120 V AC; rated input current: 10 mA (100 V AC, 60 Hz);response time: 15 ms or less (OFF to ON), 25 ms or less (ON to OFF); 32 points/common; 38-point terminal block

    QX21LAX2132 points; 200 to 240 V AC input; rated input current: 10 mA (220 V AC, 60 Hz); response time: 15 ms or less (OFF to ON), 25 ms or less (ON to OFF); 32 points/common; 38-point terminal block

    QY11ALAY10AAY11A

    QY51PLAY51AY51-S1

    16-point contact output, 24 V DC/240 V AC, 2 A/point, 16 A/all points, all points independent common, 38-point terminal block, surge suppressor (varistor 387 to 473 V

    32-point contact output, 24 V DC/240 V AC, 2 A/point, 5 A/common, 8 points/common, 38-point terminal block

    32-point triac output, 100 to 240 V AC, 0.6 A/point, 2.4 A/common, 8 points/common, 38-point terminal block

    32-point transistor output (Sink), 12/24 V DC, 0.5 A/point, 4 A/common, 16 points/common, 38-point terminal block

    Q Series large type I/O module options

    The Q Series large type base units and I/O modules are compatible with High Performance Model QCPUs, Universal Model QCPUs (except for Q00UJCPU), and MELSECNET/H Remote I/O Stations.The following CPUs and system are not compatible:Basic Model QCPUs, Process CPUs, Redundant CPUs, and Safety CPUsQ00UJCPU

    Note

    Product name

    Input module

    Large typeblank cover

    Outline

    Q Series power supply and CPU modules can be used without any modication (Q Series large type blank cover is not necessary).Q Series large type I/O modules can be used with Q Series modules. (Some modules, such as the ones that occupy two slots, cannot be mounted. For details, please refer to Q Series Large Type Base Unit User's Manual (IB-0800408).)

  • 1413

    Permits Q Series upgrade with existing 32-point I/O wiring.

    Remove the wired terminal block from the existing I/O module.

    Remove the wired terminal block from the existing I/O module.

    Q Series large type blank cover (QG69L)(To mount a standard Q Series module on a large type base unit)

    Q Series module

    Q Series module

    Mount Q Series standard power supply and CPU modules.

    Mount directly.

    Mount directly.

    QX40

    LA

    FUSE

    0

    2

    4

    6

    1

    3

    5

    7

    L8

    A

    C

    E

    9

    B

    D

    F

    L8

    A

    C

    E

    9

    B

    D

    F

    QY23LTRIACAC100

    /240V

    0.6A

    LB

    0

    2

    4

    6

    1

    3

    5

    7

    1

    3

    5

    7

    9

    11

    13

    15

    17

    19

    21

    23

    25

    27

    29

    31

    33

    35

    37

    2

    4

    6

    8

    10

    12

    14

    16

    18

    20

    22

    24

    26

    28

    30

    32

    34

    36

    38

    QY23L

    A

    0

    2

    4

    6

    1

    3

    5

    7

    COM

    COM

    COM

    COM

    8

    A

    C

    E

    9

    B

    D

    F

    8

    A

    C

    E

    9

    B

    D

    F

    QX11LAC100

    V

    10mA

    B

    0

    2

    4

    6

    1

    3

    5

    7

    1

    3

    5

    7

    9

    11

    13

    15

    17

    19

    21

    23

    25

    27

    29

    31

    33

    35

    37

    2

    4

    6

    8

    10

    12

    14

    16

    18

    20

    22

    24

    26

    28

    30

    32

    34

    36

    38

    QX11L

    LA

    0

    2

    4

    6

    1

    3

    5

    7

    L8

    A

    C

    E

    9

    B

    D

    F

    L8

    A

    C

    E

    9

    B

    D

    F

    + -

    QY13LRELAY

    AC240V 2A

    DC24V

    2A

    LB

    0

    2

    4

    6

    1

    3

    5

    7

    1

    3

    5

    7

    9

    11

    13

    15

    17

    19

    21

    23

    25

    27

    29

    31

    33

    35

    37

    2

    4

    6

    8

    10

    12

    14

    16

    18

    20

    22

    24

    26

    28

    30

    32

    34

    36

    38

    QY13LQ12HC

    PU

    MODERUNERR.

    USERBAT.

    BOOT

    PULL

    USB

    RS-232

    Q62P

    POWER

    PULL

    QX40

    LA

    FUSE

    0

    2

    4

    6

    1

    3

    5

    7

    L8

    A

    C

    E

    9

    B

    D

    F

    L8

    A

    C

    E

    9

    B

    D

    F

    QY23LTRIACAC100

    /240V

    0.6A

    LB

    0

    2

    4

    6

    1

    3

    5

    7

    QY23L

    1

    3

    5

    7

    9

    11

    13

    15

    17

    19

    21

    23

    25

    27

    29

    31

    33

    35

    37

    2

    4

    6

    8

    10

    12

    14

    16

    18

    20

    22

    24

    26

    28

    30

    32

    34

    36

    38

    1

    3

    5

    7

    9

    11

    13

    15

    17

    19

    21

    23

    25

    27

    29

    31

    33

    35

    37

    2

    4

    6

    8

    10

    12

    14

    16

    18

    20

    22

    24

    26

    28

    30

    32

    34

    36

    38

    Through the use of an upgrade tool (manufactured by Mitsubishi Electric Engineering Co., LTD., refer to page 15), terminal block modules that are not compatible with the Q Series large type I/O modules can be mounted without rewiring. For compatibility of Q Series large type base unit and upgrade tool, refer to page 16.

    Notes

    Q Series large type base unit(includes base adapter)

    Q Series large typeI/O modules

    Q Series large type I/O module

    Upgrade tool (conversion adapter) manufactured by Mitsubishi Electric Engineering Co., Ltd.

    Q38BLQ35BL

    Q68BLQ65BLQ55BL

    QX11LQX21L QG69L

    QY11ALQY13LQY23LQY51PL

    Q Series Large Type Base Unit,I/O Module ( )

    Minimize wiring modications by reusing existing A Series 32-point I/O wiring.No need to make new mounting holes. The hole size and pitch of the Q Series large type base units are the same as those of large type A Series.

    ModelProduct name

    Main base unit

    Q38BL

    Extension base unit

    Q68BL

    8 slots, 1 power supply module required,Q Series large type I/O module mountable

    Q35BL5 slots, 1 power supply module required, Q Series large type I/O module mountable

    8 slots, 1 power supply module required, Q Series large type I/O module mountable

    Q65BL5 slots, 1 power supply module required, Q Series large type I/O module mountable

    Q55BL5 slots, power supply module not required,Q Series large type I/O module mountable

    Q Series large type base unit optionsOutline

    Model

    Output module

    Blank cover for mounting existing Q Series module on the Q Series large type base unit

    QX11L

    QY13L

    QY23L

    QG69L

    AX11

    Q Serieslarge typemodule

    ExistingA Seriesmodule

    AY13

    AY23

    N/A

    32 points; 100 to 120 V AC; rated input current: 10 mA (100 V AC, 60 Hz);response time: 15 ms or less (OFF to ON), 25 ms or less (ON to OFF); 32 points/common; 38-point terminal block

    QX21LAX2132 points; 200 to 240 V AC input; rated input current: 10 mA (220 V AC, 60 Hz); response time: 15 ms or less (OFF to ON), 25 ms or less (ON to OFF); 32 points/common; 38-point terminal block

    QY11ALAY10AAY11A

    QY51PLAY51AY51-S1

    16-point contact output, 24 V DC/240 V AC, 2 A/point, 16 A/all points, all points independent common, 38-point terminal block, surge suppressor (varistor 387 to 473 V

    32-point contact output, 24 V DC/240 V AC, 2 A/point, 5 A/common, 8 points/common, 38-point terminal block

    32-point triac output, 100 to 240 V AC, 0.6 A/point, 2.4 A/common, 8 points/common, 38-point terminal block

    32-point transistor output (Sink), 12/24 V DC, 0.5 A/point, 4 A/common, 16 points/common, 38-point terminal block

    Q Series large type I/O module options

    The Q Series large type base units and I/O modules are compatible with High Performance Model QCPUs, Universal Model QCPUs (except for Q00UJCPU), and MELSECNET/H Remote I/O Stations.The following CPUs and system are not compatible:Basic Model QCPUs, Process CPUs, Redundant CPUs, and Safety CPUsQ00UJCPU

    Note

    Product name

    Input module

    Large typeblank cover

    Outline

    Q Series power supply and CPU modules can be used without any modication (Q Series large type blank cover is not necessary).Q Series large type I/O modules can be used with Q Series modules. (Some modules, such as the ones that occupy two slots, cannot be mounted. For details, please refer to Q Series Large Type Base Unit User's Manual (IB-0800408).)

  • 1615

    Compatibility of Q Series large type base unit and base adapter/conversion adapter (upgrade tool manufactured by Mitsubishi Electric Engineering Co., Ltd.)

    Compatibility of Q Series large type base unit and upgrade tool

    Slot width of base unit*2

    Power supply module

    Same width as Q Series base unit(27.4mm)

    Same width as the large type A Series base unit (37.5mm)

    Item Base adapterConversion adapter(Upgrade tool)*1 Q Series large type base unit*1

    Q Series standard power supply moduleBasic model QCPU

    CPU moduleHigh Performance model QCPUProcess CPU*3Universal model QCPUQ Series large type I/O modules*4I/O module

    Intelligent function module

    *6Q Series module (occupies 1 slot)Q Series module (occupies 2 slots)

    For terminal block type 16-point I/O module (occupies 1 slot) *6

    For terminal block type 32-point I/O module (occupies 1 slot) *8*6

    For terminal block type 32-point I/O module (occupies 2 slots) *9For high-speed counter module *8*6

    For analog module (occupies 1 slot)

    : Applicable (Mountable) : Applicable with restrictions (Mountable) : Not Applicable (Not mountable)

    *8*6

    For analog module (occupies 2 slots) *9Connection of QA/QA1S extension base unit*7

    Conversion adapter

    Mountable module

    0 1 2 3 4 5 6 7 8

    0123456789ABCDEF

    37.5

    0123456789ABCDEF

    27.4

    MELSEC-A Series module MELSEC-Q Series module

    Q68ADV(I)

    Conversion adapter

    Existing A616AD terminal block

    *1 Q Series large type base units can be used with Q Series standard base units. (The base adaptor manufactured by Mitsubishi Electric Engineering Co., Ltd. is applicable to Q Series standard base unit.)

    *2 Check mounting conditions before using the upgrade tool, because wiring space is reduced due to a decrease in the module's width.

    *3 Q00UJCPU is not compatible.*4 Number of common points and electrical specications are same as that of large type A Series I/O module.

    *5 Since the adapters are mounted on Q Series modules, the specications and functions are same as that of the Q Series modules. (Please check the transition handbook, since the specications and functions are dierent from that of large type A Series module)

    *6 Q Series large type blank cover (QG69L) is required.*7 Only High Performance Model QCPUs can be connected to the QA/QA1S extension base unit.

    *8 If the size of wire connected to the terminal block is larger than 1.25mm2, ERNT-AQTX41, AQTY41, AQTX81, AQTY81, AQT68AD, AQT68ADN, AQT68DA, and AQTD61 modules may have a mounting diculty.In this case, secure wiring space by leaving empty slots in between modules. For example, mount modules on slot No. 0, 2, 4, 6, 8, and leave slot No. 1, 3, 5, 7 empty. If the number of slots is insucient, consider using the Q Series large type base unit.

    *9 Can be used to replace an A616AD with two Q68ADV(I) modules and a conversion adapter. Doing so will allow the existing wired terminal blocks to be used.

    0123456789ABCDEF

    0123456789ABCDEF

    0123456789ABCDEF

    0123456789ABCDEF

    0123456789ABCDEF

    Replace A Series systems with Q Series withoutextensive I/O rewiring.

    The upgrade tool consists of two parts: a conversion adapter that modies existing wiring of the large type A Series input/output/analog/high-speed counter modules to correspond to the Q Series modules; and a base adapter to mount Q Series base units and secure the bottom part of the conversion adapters.

    Remove the large type A Series programmable controllers along with the base unit, install the base adapter in the same position, and mount Q Series modules. (New installation holes are unnecessary when mouting the base adaptor)

    Attach the conversion adapters to the Q Series modules.

    Remove the terminal blocks from the existing large type A Series modules and mount them on the conversion adapters. (The existing wiring can be used without modication.)

    Utilize existing wiring of the I/O and other modules.

    Upgrade tool(Base adapter)

    Upgrade tool(Conversion adapter)

    For detailed specications, precautions, and restrictions of the upgrade tool, please refer to the brochure (SAN C033E-04Z) and user's manual. For the upgrade tool, please contact your local Mitsubishi sales oce or representative.

    Upgrade Tool

    Upgrade tool features

    *5

  • 1615

    Compatibility of Q Series large type base unit and base adapter/conversion adapter (upgrade tool manufactured by Mitsubishi Electric Engineering Co., Ltd.)

    Compatibility of Q Series large type base unit and upgrade tool

    Slot width of base unit*2

    Power supply module

    Same width as Q Series base unit(27.4mm)

    Same width as the large type A Series base unit (37.5mm)

    Item Base adapterConversion adapter(Upgrade tool)*1 Q Series large type base unit*1

    Q Series standard power supply moduleBasic model QCPU

    CPU moduleHigh Performance model QCPUProcess CPU*3Universal model QCPUQ Series large type I/O modules*4I/O module

    Intelligent function module

    *6Q Series module (occupies 1 slot)Q Series module (occupies 2 slots)

    For terminal block type 16-point I/O module (occupies 1 slot) *6

    For terminal block type 32-point I/O module (occupies 1 slot) *8*6

    For terminal block type 32-point I/O module (occupies 2 slots) *9For high-speed counter module *8*6

    For analog module (occupies 1 slot)

    : Applicable (Mountable) : Applicable with restrictions (Mountable) : Not Applicable (Not mountable)

    *8*6

    For analog module (occupies 2 slots) *9Connection of QA/QA1S extension base unit*7

    Conversion adapter

    Mountable module

    0 1 2 3 4 5 6 7 8

    0123456789ABCDEF

    37.5

    0123456789ABCDEF

    27.4

    MELSEC-A Series module MELSEC-Q Series module

    Q68ADV(I)

    Conversion adapter

    Existing A616AD terminal block

    *1 Q Series large type base units can be used with Q Series standard base units. (The base adaptor manufactured by Mitsubishi Electric Engineering Co., Ltd. is applicable to Q Series standard base unit.)

    *2 Check mounting conditions before using the upgrade tool, because wiring space is reduced due to a decrease in the module's width.

    *3 Q00UJCPU is not compatible.*4 Number of common points and electrical specications are same as that of large type A Series I/O module.

    *5 Since the adapters are mounted on Q Series modules, the specications and functions are same as that of the Q Series modules. (Please check the transition handbook, since the specications and functions are dierent from that of large type A Series module)

    *6 Q Series large type blank cover (QG69L) is required.*7 Only High Performance Model QCPUs can be connected to the QA/QA1S extension base unit.

    *8 If the size of wire connected to the terminal block is larger than 1.25mm2, ERNT-AQTX41, AQTY41, AQTX81, AQTY81, AQT68AD, AQT68ADN, AQT68DA, and AQTD61 modules may have a mounting diculty.In this case, secure wiring space by leaving empty slots in between modules. For example, mount modules on slot No. 0, 2, 4, 6, 8, and leave slot No. 1, 3, 5, 7 empty. If the number of slots is insucient, consider using the Q Series large type base unit.

    *9 Can be used to replace an A616AD with two Q68ADV(I) modules and a conversion adapter. Doing so will allow the existing wired terminal blocks to be used.

    0123456789ABCDEF

    0123456789ABCDEF

    0123456789ABCDEF

    0123456789ABCDEF

    0123456789ABCDEF

    Replace A Series systems with Q Series withoutextensive I/O rewiring.

    The upgrade tool consists of two parts: a conversion adapter that modies existing wiring of the large type A Series input/output/analog/high-speed counter modules to correspond to the Q Series modules; and a base adapter to mount Q Series base units and secure the bottom part of the conversion adapters.

    Remove the large type A Series programmable controllers along with the base unit, install the base adapter in the same position, and mount Q Series modules. (New installation holes are unnecessary when mouting the base adaptor)

    Attach the conversion adapters to the Q Series modules.

    Remove the terminal blocks from the existing large type A Series modules and mount them on the conversion adapters. (The existing wiring can be used without modication.)

    Utilize existing wiring of the I/O and other modules.

    Upgrade tool(Base adapter)

    Upgrade tool(Conversion adapter)

    For detailed specications, precautions, and restrictions of the upgrade tool, please refer to the brochure (SAN C033E-04Z) and user's manual. For the upgrade tool, please contact your local Mitsubishi sales oce or representative.

    Upgrade Tool

    Upgrade tool features

    *5

  • Modules for Easy Replacement

    1817

    High-speed counter modules(-, -)

    A variety of modules are available to facilitate replacement.

    These high-speed counter modules are used to replace the large type A Series high-speed countermodules (AD61 and AD61-S1) and have the same input ltering system and counting speed.Modules can be replaced without being restrained by the specications of existing pulse generators (e.g. an encoder).

    DC input modules compatible with 6 mA rated input current (QX41-S2, QX81-S2)DC input modules compatible with 6 mA rated input current are available.When replacing large type A Series modules and utilizing the external devices as they are, the existing Q Series modules may not receive signals sent from external devices, such as proximity sensors, due to incompatibility with low-rated input current, and thus, external resistors need to be installed. With the QX41-S2 and QX81-S2 modules, which are compatible with 6 mA rated input current, external resistors are no longer required. (The existing external devices can be utilized when replacing modules.)

    I/O combined module (QX41Y41P) * A module with sequential I/O numbersQX41Y41P's I/O assignment is same as that of large type A Series I/O combined module, AH42. This module can be used as the I/O module on the programmable controller side when using the A0J2 renewal tool (manufactured by Mitsubishi Electric System & Service Co., Ltd., refer to page 23) to replace the A0J2(H)CPUIt is not necessary to change the programs when replacing AH42 or A0J2(H)CPU. (Minimize the need to modify programs)

    Input(X)

    X00

    X1F

    00

    1F32 points

    Same I/O numbers are used for input and output

    Y00

    Y1F

    Output(Y) Input(X)

    Blank

    X00

    X1F

    00

    1F32 points

    Sequential I/O numbers are used for input and output

    (QH42P) (AH42, QX41Y41P)

    Y20

    Y3F

    Output(Y)

    Blank

    20

    3F32 points

    Existing MELSECNET/B twisted pair cables are used to build the MELSECNET/H network system when replacing large type A Series modules (MELSECNET/B) with Q Series modules. Modules are replaced without modifying the previously laid network cables. A high-speed and large-volume network system can also be built using CC-Link cables.

    MELSECNET/H network system can be built using twisted pair cables.

    Utilize existing MELSECNET/B twisted pair cables

    Item

    32 stations (1 control station, 31 normal stations)Number of stations per network

    Overall distance per network

    1200 m 1200 m

    600 m 900 m

    400 m 600 m

    200 m 400 m

    200 m

    (N/A) 150 m

    156 k bps

    312 k bps

    625 k bps

    1.25 M bps

    2.5 M bps

    5 M bps

    10 M bps

    Communicationspeed

    100 m

    Twisted pair cableCable type CC-Link Ver. 1.10 compatible cable

    Twisted bus system specification

    Item

    32Number of input points

    Rated input current

    Q Series Large type A Series

    Approx. 6 mA

    (N/A)

    24 V DC

    12 V DC

    QX41-S2

    QX81-S2Positive common type

    Negative common typeModel

    Specification

    Utilize the existing MELSECNET/B twisted pair cables to build MELSECNET/H network systems.

    MELSECNET/H Network ModuleQJ71NT11B (twisted bus type)

    32

    Approx. 4 mA

    (N/A)

    QX41

    QX81

    32

    Approx. 10 mA

    Approx. 4 mA

    AX41

    AX81

    64

    Approx. 7 mA

    Approx. 3 mA

    AX42

    AX82

    Counting speed switch setting

    AD61AD61-S1

    QD62-H01QD62-H02

    50 K PPS10 K PPS

    A/QnA (Large Type) Series Models Q Series Replacement Models

    Positioning module(QD73A1)The positioning module realizes servomotor control with a high-resolution encoder, and is compatible with a 1 Mppsmaximum input pulse (x10 conventional module). Replace the positioning module while maintaining existing external devices such as the servo ampliers.

    Positioning mode

    AD70 QD73A1Position control mode

    Velocity/position control switchover mode

    A/QnA (Large Type) Series Models Q Series Replacement Models

    (Comparison of QX41-S2/QX81-S2 with large type A Series modules)

    The pin arrangement is same as that of the existing A/Q Series connector type module.Use the conversion adapter manufactured by Mitsubishi Electric Engineering Co., Ltd. when replacing a large type A Series 32-point terminal block module.

    Controlstation

    Terminatingresistor

    Normalstation

    Normalstation

    Normalstation

    Normalstation

    Normalstation

    Terminatingresistor

    New

  • Modules for Easy Replacement

    1817

    High-speed counter modules(-, -)

    A variety of modules are available to facilitate replacement.

    These high-speed counter modules are used to replace the large type A Series high-speed countermodules (AD61 and AD61-S1) and have the same input ltering system and counting speed.Modules can be replaced without being restrained by the specications of existing pulse generators (e.g. an encoder).

    DC input modules compatible with 6 mA rated input current (QX41-S2, QX81-S2)DC input modules compatible with 6 mA rated input current are available.When replacing large type A Series modules and utilizing the external devices as they are, the existing Q Series modules may not receive signals sent from external devices, such as proximity sensors, due to incompatibility with low-rated input current, and thus, external resistors need to be installed. With the QX41-S2 and QX81-S2 modules, which are compatible with 6 mA rated input current, external resistors are no longer required. (The existing external devices can be utilized when replacing modules.)

    I/O combined module (QX41Y41P) * A module with sequential I/O numbersQX41Y41P's I/O assignment is same as that of large type A Series I/O combined module, AH42. This module can be used as the I/O module on the programmable controller side when using the A0J2 renewal tool (manufactured by Mitsubishi Electric System & Service Co., Ltd., refer to page 23) to replace the A0J2(H)CPUIt is not necessary to change the programs when replacing AH42 or A0J2(H)CPU. (Minimize the need to modify programs)

    Input(X)

    X00

    X1F

    00

    1F32 points

    Same I/O numbers are used for input and output

    Y00

    Y1F

    Output(Y) Input(X)

    Blank

    X00

    X1F

    00

    1F32 points

    Sequential I/O numbers are used for input and output

    (QH42P) (AH42, QX41Y41P)

    Y20

    Y3F

    Output(Y)

    Blank

    20

    3F32 points

    Existing MELSECNET/B twisted pair cables are used to build the MELSECNET/H network system when replacing large type A Series modules (MELSECNET/B) with Q Series modules. Modules are replaced without modifying the previously laid network cables. A high-speed and large-volume network system can also be built using CC-Link cables.

    MELSECNET/H network system can be built using twisted pair cables.

    Utilize existing MELSECNET/B twisted pair cables

    Item

    32 stations (1 control station, 31 normal stations)Number of stations per network

    Overall distance per network

    1200 m 1200 m

    600 m 900 m

    400 m 600 m

    200 m 400 m

    200 m

    (N/A) 150 m

    156 k bps

    312 k bps

    625 k bps

    1.25 M bps

    2.5 M bps

    5 M bps

    10 M bps

    Communicationspeed

    100 m

    Twisted pair cableCable type CC-Link Ver. 1.10 compatible cable

    Twisted bus system specification

    Item

    32Number of input points

    Rated input current

    Q Series Large type A Series

    Approx. 6 mA

    (N/A)

    24 V DC

    12 V DC

    QX41-S2

    QX81-S2Positive common type

    Negative common typeModel

    Specification

    Utilize the existing MELSECNET/B twisted pair cables to build MELSECNET/H network systems.

    MELSECNET/H Network ModuleQJ71NT11B (twisted bus type)

    32

    Approx. 4 mA

    (N/A)

    QX41

    QX81

    32

    Approx. 10 mA

    Approx. 4 mA

    AX41

    AX81

    64

    Approx. 7 mA

    Approx. 3 mA

    AX42

    AX82

    Counting speed switch setting

    AD61AD61-S1

    QD62-H01QD62-H02

    50 K PPS10 K PPS

    A/QnA (Large Type) Series Models Q Series Replacement Models

    Positioning module(QD73A1)The positioning module realizes servomotor control with a high-resolution encoder, and is compatible with a 1 Mppsmaximum input pulse (x10 conventional module). Replace the positioning module while maintaining existing external devices such as the servo ampliers.

    Positioning mode

    AD70 QD73A1Position control mode

    Velocity/position control switchover mode

    A/QnA (Large Type) Series Models Q Series Replacement Models

    (Comparison of QX41-S2/QX81-S2 with large type A Series modules)

    The pin arrangement is same as that of the existing A/Q Series connector type module.Use the conversion adapter manufactured by Mitsubishi Electric Engineering Co., Ltd. when replacing a large type A Series 32-point terminal block module.

    Controlstation

    Terminatingresistor

    Normalstation

    Normalstation

    Normalstation

    Normalstation

    Normalstation

    Terminatingresistor

    New

  • 2019

    MELSECNET(), MELSECNET/BLocal Station Data Link Module

    Upgraded AnS local station data link modules permit a directQ Series connection to existing networks as local stations.

    A1SJ71AP23QA1SJ71AR23QA1SJ71AT23BQ

    Replace A Series MELSECNET(), MELSECNET/B stations with Q Series systems.The MELSECNET()/B local station data link modules allow a Q Series system to directly connect to existing NET()/NET/B data link system via a QA1S6B extension base unit.

    MELSECNET ()

    MELSECNET(), MELSECNET/BLocal station data link module

    High performance model QCPU0123456789ABCDEF

    0123456789ABCDEF

    0123456789ABCDEF

    0123456789ABCDEF

    Master station

    Local station

    Example of a MELSECNET() conguration incorporating the Q Series

    Local station

    Model

    A1SJ71AP23Q

    A1SJ71AR23Q

    A1SJ71AT23BQ

    MELSECNET() local station data link module for SI optical ber cable

    MELSECNET() local station data link module for coaxial cable

    MELSECNET/B local station data link module for shielded twisted pair cable

    Local station data link module optionsOutline

    Specications

    /Supported CPUsHigh Performance Model QCPUs [Q02(H), Q06H, Q12H, and Q25HCPU]0Compatible extension base unitsQA1S6B or QA6B with A-A1S module conversion adapter (A1ADP)1Number of modules per CPUSend point range can be further increased by mounting up to 6 modules per CPU.2Network parametersMinimal setup required, as network parameters settings are automatically detected by the module.3Link refresh settingLink refresh setting is not automatically detected. Hence, FROM/TO instructions within sequence program toenable send/receive cyclic data are required.

    Sample programs for link refresh are provided in the "A/QnA Q Conversion Support Tool." The sample program can be used to create a QCPU program which may reduce development time.For details, please contact your local Mitsubishi sales oce or representative.

    MELSECNET()-MELSECNET/10Gateway Set (Q6KT-NETGW-)

    Use a Q2AS based MELSECNET()/10 gateway to gradually convert MELSECNET() stations to MELSECNET/10. MELSECNET/10 is backwards compatible with the Q Series via MELSECNET/H.

    Before transition Transitional step Transition completed

    Step-by-step replacement with the Q Series

    Set model name

    Q6KT-NETGW-SS

    Q6KT-NETGW-RS

    Q6KT-NETGW-RB

    Q6KT-NETGW-TS

    Q6KT-NETGW-TB

    Q6KT-NETGW-

    A1SJ71QLP21

    A1SJ71QLP21

    A1SJ71QBR11

    A1SJ71QLP21

    A1SJ71QBR11

    A1SJ71AP21

    A1SJ71AT21B

    A1SJ71AR21A1S35B A1S61PN Q2ASCPU

    Gateway set optionsMain part MELSECNET/10 partMELSECNET()/B part

    Implement gradual migration from MELSECNET() to MELSECNET/10.

    (Example) Partial replacement of MELSECNET(), from large type A Seriesprogrammable controllers to Q Series programmable controllers

    MELSECNET()

    Please check the cautions and restrictions for the gatewaystation network parameters etc. in the related manuals.

    A1

    A2 A5

    A3 A4

    A Series system Q Series systemAn Qn

    A2

    A3 Q4

    Q5A1

    MELSECNET()

    MELSECNET/10

    MELSECNET/H(10)

    Q1

    Q2 Q5

    Q3 Q4Use a gateway toincorporate theQ Series systeminto the existingsystem.

    Step-by-stepreplacement for theentire system conversionto the Q Series.

    Readingthe modelname

    /Network type MELSECNET SI optical ber cable (double loop) Coaxial cable (double loop) Twisted pair cable (bus)

    /

    0Network type MELSECNET/10 SI optical ber cable (double loop) Coaxial cable (bus)Gateway set 0

    0123456789ABCDEF

    0123456789ABCDEF

    0123456789ABCDEF

    MELSECNET/10

    Gateway set Q Series

    MELSECNET()

    NET()Localstation

    NET/10Controlstation

    NET/10Normalstation

    GatewayGateway

    QA1S51BQA1S65BQA1S68B

    Extension base unit with 1 slot (power supply module not required)

  • 2019

    MELSECNET(), MELSECNET/BLocal Station Data Link Module

    Upgraded AnS local station data link modules permit a directQ Series connection to existing networks as local stations.

    A1SJ71AP23QA1SJ71AR23QA1SJ71AT23BQ

    Replace A Series MELSECNET(), MELSECNET/B stations with Q Series systems.The MELSECNET()/B local station data link modules allow a Q Series system to directly connect to existing NET()/NET/B data link system via a QA1S6B extension base unit.

    MELSECNET ()

    MELSECNET(), MELSECNET/BLocal station data link module

    High performance model QCPU0123456789ABCDEF

    0123456789ABCDEF

    0123456789ABCDEF

    0123456789ABCDEF

    Master station

    Local station

    Example of a MELSECNET() conguration incorporating the Q Series

    Local station

    Model

    A1SJ71AP23Q

    A1SJ71AR23Q

    A1SJ71AT23BQ

    MELSECNET() local station data link module for SI optical ber cable

    MELSECNET() local station data link module for coaxial cable

    MELSECNET/B local station data link module for shielded twisted pair cable

    Local station data link module optionsOutline

    Specications

    /Supported CPUsHigh Performance Model QCPUs [Q02(H), Q06H, Q12H, and Q25HCPU]0Compatible extension base unitsQA1S6B or QA6B with A-A1S module conversion adapter (A1ADP)1Number of modules per CPUSend point range can be further increased by mounting up to 6 modules per CPU.2Network parametersMinimal setup required, as network parameters settings are automatically detected by the module.3Link refresh settingLink refresh setting is not automatically detected. Hence, FROM/TO instructions within sequence program toenable send/receive cyclic data are required.

    Sample programs for link refresh are provided in the "A/QnA Q Conversion Support Tool." The sample program can be used to create a QCPU program which may reduce development time.For details, please contact your local Mitsubishi sales oce or representative.

    MELSECNET()-MELSECNET/10Gateway Set (Q6KT-NETGW-)

    Use a Q2AS based MELSECNET()/10 gateway to gradually convert MELSECNET() stations to MELSECNET/10. MELSECNET/10 is backwards compatible with the Q Series via MELSECNET/H.

    Before transition Transitional step Transition completed

    Step-by-step replacement with the Q Series

    Set model name

    Q6KT-NETGW-SS

    Q6KT-NETGW-RS

    Q6KT-NETGW-RB

    Q6KT-NETGW-TS

    Q6KT-NETGW-TB

    Q6KT-NETGW-

    A1SJ71QLP21

    A1SJ71QLP21

    A1SJ71QBR11

    A1SJ71QLP21

    A1SJ71QBR11

    A1SJ71AP21

    A1SJ71AT21B

    A1SJ71AR21A1S35B A1S61PN Q2ASCPU

    Gateway set optionsMain part MELSECNET/10 partMELSECNET()/B part

    Implement gradual migration from MELSECNET() to MELSECNET/10.

    (Example) Partial replacement of MELSECNET(), from large type A Seriesprogrammable controllers to Q Series programmable controllers

    MELSECNET()

    Please check the cautions and restrictions for the gatewaystation network parameters etc. in the related manuals.

    A1

    A2 A5

    A3 A4

    A Series system Q Series systemAn Qn

    A2

    A3 Q4

    Q5A1

    MELSECNET()

    MELSECNET/10

    MELSECNET/H(10)

    Q1

    Q2 Q5

    Q3 Q4Use a gateway toincorporate theQ Series systeminto the existingsystem.

    Step-by-stepreplacement for theentire system conversionto the Q Series.

    Readingthe modelname

    /Network type MELSECNET SI optical ber cable (double loop) Coaxial cable (double loop) Twisted pair cable (bus)

    /

    0Network type MELSECNET/10 SI optical ber cable (double loop) Coaxial cable (bus)Gateway set 0

    0123456789ABCDEF

    0123456789ABCDEF

    0123456789ABCDEF

    MELSECNET/10

    Gateway set Q Series

    MELSECNET()

    NET()Localstation

    NET/10Controlstation

    NET/10Normalstation

    GatewayGateway

    QA1S51BQA1S65BQA1S68B

    Extension base unit with 1 slot (power supply module not required)

  • 2221

    Further network upgrade options are available because of the continued production of MELSECNET/10 modules. A complete MELSECNET() system can be replaced with MELSECNET/10 while reusing the existing cable installations. Following the network replacement, the A series stations can be replaced with Q series stations as needed in a step-by-step manner. However, the step-by-step transition is not possible if the network includes of a combination of A/QnA series and Q series stations, because the A/QnA series does not support MELSECNET/H twisted bus system.

    Q Series Options with MELSECNET/10Network Modules

    Complete replacement of MELSECNET() systems with MELSECNET/10 while reusing existing cable installations.

    A Series system

    Q Series system

    An

    Qn

    MELSECNET

    Before transition Transitional step 1(One or more AnU or QnACPU modulesare required as a control station.)

    Transitional step 2

    A1

    A2 A5

    A3 A4

    MELSECNET/10

    A1

    A2 A5

    A3 A4

    MELSECNET/10

    Q1

    A2 A5

    Q3 A4

    Transition completed

    MELSECNET/H(10)

    Q1

    Q2 Q5

    Q3 Q4

    Step-by-step transition from an A Series and Q Series combined system to a Q Series system.

    Replace MELSECNET() data link modules at all stations with MELSECNET/10 network modules, and then switch the network system over to MELSECNET/10.

    For stations that are to be changed from A Series systems to Q Series systems, replace the programmable controllers to the Q Series, and set them as MELSECNET/10 normal stations.By gradually transferring the A Series systems to the Q Series systems, you will be able to complete the transition to the Q Series system.

    Change the MELSECNET() master station to the MELSECNET/10 control station.Note: For CPU modules (AnNCPU and AnACPU) that cannot be

    set as the MELSECNET/10 control stations, please consider changing to the Q Series.

    Set the MELSECNET() local stations to the MELSECNET/10 normal stations.

    Network module options

    Product name

    Large type A/QnA SeriesMELSECNET/10 network module

    Model

    Control/normal station Remote I/O station

    AJ71BR11AJ71LP21AJ71LP21GAJ71LR21AJ71QBR11AJ71QLP21AJ71QLP21GAJ71QLP21SAJ71QLR21

    AJ72BR15AJ72LP25AJ72LP25GAJ72LR25AJ72QBR15AJ72QLP25AJ72QLP25GAJ72QLR25

    Select the best-suited Q Series redundant systemconguration for the application.

    Q Series Redundant System

    Realizes local I/O system equivalent to Q4ARCPU using the redundant type extension base unit.

    Up to 63 modules can be mounted using the redundant type extension base unit.Fast system switching time at (approx.) 50 ms in the redundant local I/O system, remarkable improvement compared to the Q4ARCPU redundant system (300 ms + 1 scan time).

    Simple upgrades from legacy Q4AR installations to modern Q Series redundant systems.

    A61RPA4UCPU

    A61RPA4UCPU

    Tracking cable

    Remote I/O station Remote I/O station

    MELSECNET/H remote I/O network

    Tracking cable

    Normal station Normal station

    MELSECNET/H PLC to PLC network

    Tracking cable

    Main base unit

    Redundant type extension base unit (for the rst extension base unit)

    Redundant power extension base unit

    Extension cable

    Extension cable

    Control systemRedundant CPU

    Standby systemRedundant CPU

    Redundant typeextension base unitQ65WRB

    Q4ARCPU redundant systemConguration options

    Local I/O system(with extension base unit)

    MELSECNET/10PLC to PLC network

    MELSECNET/10remote I/O network

    Remote I/O network

    Extension base unit

    PLC to PLCnetwork

    Control systemRedundant CPU

    Standby systemRedundant CPU

    Control systemRedundant CPU

    Standby systemRedundant CPU

    Network modules of MELSECNET/H PLC to PLC network and remote I/O network can be mounted on the Q Series redundant CPU main base. (They can be used together.)A wide variety of system is constructed to suit the needs of the control target.

  • 2221

    Further network upgrade options are available because of the continued production of MELSECNET/10 modules. A complete MELSECNET() system can be replaced with MELSECNET/10 while reusing the existing cable installations. Following the network replacement, the A series stations can be replaced with Q series stations as needed in a step-by-step manner. However, the step-by-step transition is not possible if the network includes of a combination of A/QnA series and Q series stations, because the A/QnA series does not support MELSECNET/H twisted bus system.

    Q Series Options with MELSECNET/10Network Modules

    Complete replacement of MELSECNET() systems with MELSECNET/10 while reusing existing cable installations.

    A Series system

    Q Series system

    An

    Qn

    MELSECNET

    Before transition Transitional step 1(One or more AnU or QnACPU modulesare required as a control station.)

    Transitional step 2

    A1

    A2 A5

    A3 A4

    MELSECNET/10

    A1

    A2 A5

    A3 A4

    MELSECNET/10

    Q1

    A2 A5

    Q3 A4

    Transition completed

    MELSECNET/H(10)

    Q1

    Q2 Q5

    Q3 Q4

    Step-by-step transition from an A Series and Q Series combined system to a Q Series system.

    Replace MELSECNET() data link modules at all stations with MELSECNET/10 network modules, and then switch the network system over to MELSECNET/10.

    For stations that are to be changed from A Series systems to Q Series systems, replace the programmable controllers to the Q Series, and set them as MELSECNET/10 normal stations.By gradually transferring the A Series systems to the Q Series systems, you will be able to complete the transition to the Q Series system.

    Change the MELSECNET() master station to the MELSECNET/10 control station.Note: For CPU modules (AnNCPU and AnACPU) that cannot be

    set as the MELSECNET/10 control stations, please consider changing to the Q Series.

    Set the MELSECNET() local stations to the MELSECNET/10 normal stations.

    Network module options

    Product name

    Large type A/QnA SeriesMELSECNET/10 network module

    Model

    Control/normal station Remote I/O station

    AJ71BR11AJ71LP21AJ71LP21GAJ71LR21AJ71QBR11AJ71QLP21AJ71QLP21GAJ71QLP21SAJ71QLR21

    AJ72BR15AJ72LP25AJ72LP25GAJ72LR25AJ72QBR15AJ72QLP25AJ72QLP25GAJ72QLR25

    Select the best-suited Q Series redundant systemconguration for the application.

    Q Series Redundant System

    Realizes local I/O system equivalent to Q4ARCPU using the redundant type extension base unit.Up to 63 modules can be mounted using the redundant type extension base unit.Fast system switching time at (approx.) 50 ms in the redundant local I/O system, remarkable improvement compared to the Q4ARCPU redundant system (300 ms + 1 scan time).

    Simple upgrades from legacy Q4AR installations to modern Q Series redundant systems.

    A61RPA4UCPU

    A61RPA4UCPU

    Tracking cable

    Remote I/O station Remote I/O station

    MELSECNET/H remote I/O network

    Tracking cable

    Normal station Normal station

    MELSECNET/H PLC to PLC network

    Tracking cable

    Main base unit

    Redundant type extension base unit (for the rst extension base unit)

    Redundant power extension base unit

    Extension cable

    Extension cable

    Control systemRedundant CPU

    Standby systemRedundant CPU

    Redundant typeextension base unitQ65WRB

    Q4ARCPU redundant systemConguration options

    Local I/O system(with extension base unit)

    MELSECNET/10PLC to PLC network

    MELSECNET/10remote I/O network

    Remote I/O network

    Extension base unit

    PLC to PLCnetwork

    Control systemRedundant CPU

    Standby systemRedundant CPU

    Control systemRedundant CPU

    Standby systemRedundant CPU

    Network modules of MELSECNET/H PLC to PLC network and remote I/O network can be mounted on the Q Series redundant CPU main base. (They can be used together.)A wide variety of system is constructed to suit the needs of the control target.

  • 2423

    Before replacement

    After replacement

    Stackable typeSuitable when there is enoughdepth. Stack the programmablecontroller on the existing panelface.

    Note: Depth of 236 mm ormore is required (whentwo interface modulesare stacked).

    Flat mounting typeSuitable when there is enoughspace above existing modules.Mount the programmablecontroller above the interfacemodule(s).

    Note: Space of 92 mm ormore from the top of theexisting modules isrequired.

    Note: For the AnS Series,the standalone typeonly.

    Standalone typeMount the programmablecontroller separately.

    A0J2(H) Series I/O module

    A0J2(H) CPU module

    A0J2 renewal tool features

    Replace A0J2(H) systems with Q Series using existing wiring.

    The A0J2 renewal tool is used to replace the A0J2(H) systems with Q Series systems. It consists of an interface module to which the existing wired terminal block can be mounted, and a base adapter that can be installed using the existing installation holes.A variety of installation methods is available to t the installation space.

    Interface module featuresThe interface module has DC to relay output conversion and AC to DC input conversion functions. Hence, replacement is possible together with Q Series connector type DC I/O modules. Dedicated cables are used to connect the interface module to Q Series I/O modules.

    Structure

    Basic conguration

    (Example) 2-level stack, stackable type

    Q Series programmable controller

    Mounting plate To x programmable controllers: 3-slot and 5-slot

    Mounting frame 2-level, for stackable type

    Terminal block for 100/200 V AC relay

    Base adapter for 56Large width base adaptor

    Shape after assembly

    indicates a part of the programmable controller xing frame set.

    Before replacement

    A0J2(H) Series programmable controller

    CPU module

    I/O module

    After replacement

    Q Series programmable controller

    Main base unit(Q33B)Power supply module(Q62P)*1

    CPU moduleI/O module

    A0J2 renewal tool*3

    Interface moduleProgrammable controller xing frame set*2

    Programmable controller connection cable

    *1: The interface modules except for some models require 24 V DC power supply. If the Q62P is not used, provide a separate external power supply.

    *2: Includes a base adapter, mounting plate, mounting frame, terminal block, and power supply cable.*3: See the following list for the applicable interface module.

    Interface modulefor 24/28

    Interface modulefor 56

    Compatible interface module list

    For detailed specications, precautions, and restrictions of the A0J2 renewal tool, please refer to the brochure (X900904-165) and user's manual. For further information, For details of the A0J2 renewal tool, please contact your local Mitsubishi sales oce or representative.

    1. When upgrading to the Q Series module, programs do not need to be modied if the I/O combined module "QX41Y41P (32-point input for the rst half and 32-point output for the second half)" is used. (Refer to page 17)

    2. The A0J2 renewal tool can be used to replace MELSECNET/MINI compact type I/O modules (AJ35PTF- (such as 28AR and 56DR)) with CC-Link modules.

    3. For products that are not described (such as connection cables for programmable controller), please contact your local Mitsubishi sales oce or representative

    A0J2 Renewal Tool

    Discontinued model Replacement interface module Discontinued model Replacement interface module

    A0J2-E32A

    A0J2-E32D

    A0J2-E24R

    A0J2-E24S

    A0J2-E24T

    A0J2-E28AR

    A0J2-E28AS

    A0J2-E28DR

    SC-A0JQIF-32A

    SC-A0JQIF-32D

    SC-A0JQIF-24R

    SC-A0JQIF-24S

    SC-A0JQIF-24T

    SC-A0JQIF-28AR

    SC-A0JQIF-28AS

    SC-A0JQIF-28DR

    A0J2-E28DS

    A0J2-E28DT

    A0J2-E56AR

    A0J2-E56AS

    A0J2-E56DR

    A0J2-E56DS

    A0J2-E56DT

    SC-A0JQIF-28DS

    SC-A0JQIF-28DT

    SC-A0JQIF-56AR

    SC-A0JQIF-56AS

    SC-A0JQIF-56DR

    SC-A0JQIF-56DS

    SC-A0JQIF-56DT

    Input module

    Output module

    I/O module

    I/O module

  • 2423

    Before replacement

    After replacement

    Stackable typeSuitable when there is enoughdepth. Stack the programmablecontroller on the existing panelface.

    Note: Depth of 236 mm ormore is required (whentwo interface modulesare stacked).

    Flat mounting typeSuitable when there is enoughspace above existing modules.Mount the programmablecontroller above the interfacemodule(s).

    Note: Space of 92 mm ormore from the top of theexisting modules isrequired.

    Note: For the AnS Series,the standalone typeonly.

    Standalone typeMount the programmablecontroller separately.

    A0J2(H) Series I/O module

    A0J2(H) CPU module

    A0J2 renewal tool features

    Replace A0J2(H) systems with Q Series using existing wiring.

    The A0J2 renewal tool is used to replace the A0J2(H) systems with Q Series systems. It consists of an interface module to which the existing wired terminal block can be mounted, and a base adapter that can be installed using the existing installation holes.A variety of installation methods is available to t the installation space.

    Interface module featuresThe interface module has DC to relay output conversion and AC to DC input conversion functions. Hence, replacement is possible together with Q Series connector type DC I/O modules. Dedicated cables are used to connect the interface module to Q Series I/O modules.

    Structure

    Basic conguration

    (Example) 2-level stack, stackable type

    Q Series programmable controller

    Mounting plate To x programmable controllers: 3-slot and 5-slot

    Mounting frame 2-level, for stackable type

    Terminal block for 100/200 V AC relay

    Base adapter for 56Large width base adaptor

    Shape after assembly

    indicates a part of the programmable controller xing frame set.

    Before replacement

    A0J2(H) Series programmable controller

    CPU module

    I/O module

    After replacement

    Q Series programmable controller

    Main base unit(Q33B)Power supply module(Q62P)*1

    CPU moduleI/O module

    A0J2 renewal tool*3

    Interface moduleProgrammable controller xing frame set*2

    Programmable controller connection cable

    *1: The interface modules except for some models require 24 V DC power supply. If the Q62P is not used, provide a separate external power supply.

    *2: Includes a base adapter, mounting plate, mounting frame, terminal block, and power supply cable.*3: See the following list for the applicable interface module.

    Interface modulefor 24/28

    Interface modulefor 56

    Compatible interface module list

    For detailed specications, precautions, and restrictions of the A0J2 renewal tool, please refer to the brochure (X900904-165) and user's manual. For further information, For details of the A0J2 renewal tool, please contact your local Mitsubishi sales oce or representative.

    1. When upgrading to the Q Series module, programs do not need to be modied if the I/O combined module "QX41Y41P (32-point input for the rst half and 32-point output for the second half)" is used. (Refer to page 17)

    2. The A0J2 renewal tool can be used to replace MELSECNET/MINI compact type I/O modules (AJ35PTF- (such as 28AR and 56DR)) with CC-Link modules.

    3. For products that are not described (such as connection cables for programmable controller), please contact your local Mitsubishi sales oce or representative

    A0J2 Renewal Tool

    Discontinued model Replacement interface module Discontinued model Replacement interface module

    A0J2-E32A

    A0J2-E32D

    A0J2-E24R

    A0J2-E24S

    A0J2-E24T

    A0J2-E28AR

    A0J2-E28AS

    A0J2-E28DR

    SC-A0JQIF-32A

    SC-A0JQIF-32D

    SC-A0JQIF-24R

    SC-A0JQIF-24S

    SC-A0JQIF-24T

    SC-A0JQIF-28AR

    SC-A0JQIF-28AS

    SC-A0JQIF-28DR

    A0J2-E28DS

    A0J2-E28DT

    A0J2-E56AR

    A0J2-E56AS

    A0J2-E56DR

    A0J2-E56DS

    A0J2-E56DT

    SC-A0JQIF-28DS

    SC-A0JQIF-28DT

    SC-A0JQIF-56AR

    SC-A0JQIF-56AS

    SC-A0JQIF-56DR

    SC-A0JQIF-56DS

    SC-A0JQIF-56DT

    Input module

    Output module

    I/O module

    I/O module

  • 2625

    A2C Shape CC-Link Remote I/O Module

    Replace A2CCPU and NET/MINI-S3 I/O modules withCC-Link using existing NET/MINI-S3 wiring.

    MELSECNET/MINI-S3 I/O Module Wiring Conversion Adapter

    Replace NET/MINI-S3 systems with CC-Link whilereusing existing NET/MINI-S3 wiring.

    Wiring adapter terminal blocks eliminate the need to rewire.The simple replacement process helps minimize the upgrade time.The installation size is the same as that of A2C I/O modules; existing terminal block can be mounteddirectly. (Example) Replacing AJ35TB2-16D with AJ65BTB2-16D using a 34-pin conversion adapter

    After replacingthe module,mount the wiredterminal block.*1

    Remove the wiredterminal block fromthe existing I/Omodule.

    AX41CAX81C

    AX40Y50C

    AX40Y10C

    AY13C

    AY51C

    AJ65DBTB1-32D

    AJ65DBTB1-32T1

    AJ65DBTB1-32DT1

    AJ65DBTB1-32R

    AJ65DBTB1-32DR

    Terminal block type, 24 V DC input, 32 points, sink/source

    Terminal block type, 24 V DC input, 16 points; 0.5 A transistor output, 16 points, I/O composite module

    Terminal block type, relay output, 32 points

    Terminal block type, 24 V DC input, 16 points;relay output, 16 points, I/O composite module

    Terminal block type, 0.5 A transistor output, 32 points, sink

    Discontinued modelAlternative model

    Model Outline

    MELSECNET/MINI-S3 I/O module(AJ35TB2-16D)

    Before replacement

    *1 The communication cables and power cables need to be rewired.

    Model list

    After replacement

    Replace with the CC-Link I/O module (AJ65BTB2-16D)

    Remove the terminal block of theCC-Link I/O module, and then installthe conversion adapter.

    Rewire the CC-Link cablesand power cables only.

    No modication is necessary for I/O wiring since the existing terminal block of the MELSECNET/MINI-S3 I/O module can be used.

    Wiringconversionadapter

    Discontinued model

    Alternative module Conversion adapter

    Output module

    AJ35TB1-16D AJ65BTB1-16DWiring conversion adapter for 26-point terminal block*1A6ADP-1MC16D

    AJ35TB2-16D AJ65BTB2-16DWiring conversion adapter for 34-point terminal block*1A6ADP-2MC16D

    AJ35TB1-16T

    Product name Model

    Alternative model

    AJ65BTB1-16TWiring conversion adapter for 26-point terminal block*1, *2A6ADP-1MC16T

    Model list

    *1: The overall size is increased due to addition of the adapter to th