trane downflow/horizontal condensing, gas-fired furnace
TRANSCRIPT
Downflow/HorizontalCondensing,Gas-Fired Furnace
XB 90TDC1B040A9241A, TDC1B060A9361ATDC1B080A9421A, TDC1C100A9481ATDC1D120A9601A
Single-Stage Fan AssistedCombustion System
PUB. NO. 22-1670-04
TDD-D-1
2 Pub. No. 22-1670-04
GeneralFeatures
©American Standard Inc. 2007
NATURAL GAS MODELSCentral Heating furnace designs arecertified by the American Gas Associationfor both natural and L.P. gas. Limitsetting and rating data were establishedand approved under standard ratingconditions using American NationalStandards Institute standards.
SAFE OPERATIONThe Integrated System Control has solidstate devices, which continuously monitorfor presence of flame, when the systemis in the heating mode of operation. Dualsolenoid combination gas valve andregulator provide extra safety.
QUICK HEATINGDurable, cycle tested, heavy gaugealuminized steel heat exchangerquickly transfers heat to provide warmconditioned air to the structure. Lowenergy power vent blower, to increaseefficiency and provide a positivedischarge of gas fumes to the outside.
BURNERSMultiport Inshot burners will give years ofquiet and efficient service. All modelscan be converted to L.P. gas withoutchanging burners.
INTEGRATED SYSTEM CONTROLExclusively designed operationalprogram provides total control of furnacelimit sensors, blowers, gas valve, flamecontrol and includes self diagnostics forease of service. Also containsconnection points for E.A.C./humidifier.
AIR DELIVERYThe variable speed, direct drive blowermotor, has sufficient airflow for mostheating and cooling requirements, willswitch from heating to cooling speeds ondemand from room thermostat. Theblower door safety switch will prevent orterminate furnace operation when theblower door is removed.
STYLINGHeavy gauge steel and “wrap-around”cabinet construction is used in thecabinet with baked-on enamel finish forstrength and beauty. The heat exchangersection of the cabinet is completely linedwith foil faced fiberglass insulation. Thisresults in quiet and efficient operationdue to the excellent acoustical andinsulating qualities of fiberglass. Built-inbottom pan and alternate bottom, left orright side return air connection provision.
FEATURES ANDGENERAL OPERATIONThe XV 80 High Efficiency Gas Furnacesemploy a Hot Surface Ignition system,which eliminates the waste of a constantburning pilot. The integrated systemcontrol lights the main burners upon ademand for heat from the roomthermostat. Complete front serviceaccess.a. Low energy power venterb. Vent proving pressure switch.
3Pub. No. 22-1670-04
Contents
Feature Summary
Features and BenefitsStandard EquipmentOptional Equipment
General DataTDC1B040A9241ATDC1B060A9361ATDC1B080A9421ATDC1C100A9481ATDC1D120A9601A
Performance Data
Electrical Data
Field Wiring
Dimensions
2
4
6
8
9
11
13
4 Pub. No. 22-1670-04
Featuresand Benefits
XB 90 STANDARD EQUIPMENT• Downflow power supply 115/1/60
• Downflow convertible to horizontal onleft side
• Type 29-4CTM stainless steel
secondary heat exchanger
• Inner blower doors
• Direct drive, 4-speed motor
• Hot surface igniter with adaptive heatup
• Accessory hook-up capability - Humand EAC
• Quiet induced draft blower
• Blower door safety switch
• Dual solenoid combination gas valve& regulator
• PVC venting - 1 Pipe
• Left/right gas connection
• Selectable cooling fan off delayeliminates need for BAY24X045 timedelay relay
• Integrated solid state control withself diagnostics
• 24 volt fuse
• Manual reset burner box limit
• Lifetime limited primary heatexchanger or secondary heatexchanger warranty to originalowner (Residential use)
• 3-year limited warranty onintegrated ignition control andhot surface igniter(Residential use)
• Optional extended warranties
5Pub. No. 22-1670-04
Featuresand Benefits
XB 90 OPTIONAL EQUIPMENT
Thermostat, Mechanical Heating Only With Fan Switch ............................................................................................ BAYSTAT303 [ ]Thermostat, Heating/Cooling Single Stage (Mounts Horizontally) ................................................................................. AY28X092 [ ]Thermostat, Heating/Cooling Single Stage (Mounts Vertically) ................................................................................ BAYSTAT305 [ ]Thermostat, Electronic Programmable 1-Stage Heating/1-Stage Cooling ............................................................... BAYSTAT300 [ ]Propane Conversion Kit ........................................................................................................................................ BAYLPKT210A [ ]Electronic Air Filter, “Perfect Fit” Super Efficiency (17-1/2" Wide Gas Furnace) ....................................................... TFE175A9FR0 [ ]Electronic Air Filter, “Perfect Fit” Super Efficiency (21" Wide Gas Furnace) ............................................................. TFE210A9FR0 [ ]Electronic Air Filter, “Perfect Fit” Super Efficiency (24-1/2" Wide Gas Furnace) ....................................................... TFE245A9FR0 [ ]Electronic Air Filter, “Perfect Fit” High Efficiency (17-1/2" Wide Gas Furnace) ........................................................ TFM175A9FR0 [ ]Electronic Air Filter, “Perfect Fit” High Efficiency (21" Wide Gas Furnace) .............................................................. TFM210A9FR0 [ ]Electronic Air Filter, “Perfect Fit” High Efficiency (24-1/2" Wide Gas Furnace) ........................................................ TFM245A9FR0 [ ]Electronic Air Filter, “Perfect Fit” Standard Efficiency (17-1/2" Wide Gas Furnace) .................................................. TFP175A9FR0 [ ]Electronic Air Filter, “Perfect Fit” Standard Efficiency (21" Wide Gas Furnace) ........................................................ TFP210A9FR0 [ ]Electronic Air Filter, “Perfect Fit” Standard Efficiency (24-1/2" Wide Gas Furnace) .................................................. TFP245A9FR0 [ ]Coil Enclosure (17-1/2" Wide Cabinets) ...................................................................................................................BAYCLE1700 [ ]Coil Enclosure (21" Wide Cabinets) .........................................................................................................................BAYCLE2100 [ ]Coil Enclosure (24-1/2" Wide Cabinets) ...................................................................................................................BAYCLE2400 [ ]Side Filter Rack ........................................................................................................................................................ BAYFLTR200 [ ]High Altitude Switch ................................................................................................................................................. BAYHALT239 [ ]
6 Pub. No. 22-1670-04
GeneralData
1 Central Furnace heating designs are certified by the American Gas Association Inc. Laboratories.2 Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet; Ratings should be reduced at the rate of 4% for each 1000 feet above sea level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
MODELTYPERATINGS 22222Input BTUHCapacity BTUH (ICS) 33333AFUETemp. rise (Min.-Max.) °F.BLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HPR.P.M.Volts / Ph / HzCOMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLAFILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)VENT — Size (in.)HEAT EXCHANGERType-Fired
-UnfiredGauge (Fired)ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill SizeGAS VALVEPILOT SAFETY DEVICETypeBURNERS — TypeNumberPOWER CONN. — V / Ph / Hz 44444Ampacity (In Amps)Max Overcurrent Protection (Amps)PIPE CONN. SIZE (IN.)DIMENSIONSCrated (In.)WEIGHTShipping (Lbs.) / Net (Lbs)
PRODUCT SPECIFICATIONS 11111TDC1B040A9241A
Downflow / Horizontal
40,00038,00090.0
30 - 60DIRECT10 x 7
14
See Fan Performance Table1/5
1080115/1/60
CentrifugalDirect - 1
1/55 - 3000115/1/60
1.0No
High Velocity2 - 14x20 - 1in.
2 Round
Aluminized Steel - Type I
20
2 — 452 — 56
Redundant - Single Stage
Hot Surface IgnitionMultiport Inshot
2115/1/60
4.7151/2
H x W x D41-3/4 x 19-1/2 x 30-1/2
145 / 135
TDC1B060A9361ADownflow / Horizontal
60,00056,00090.0
35 - 65DIRECT10 x 8
14
See Fan Performance Table1/3
1075115/1/60
CentrifugalDirect - 1
1/55 - 3000115/1/60
1.0No
High Velocity2 - 14x20 - 1in.
2 Round
Aluminized Steel - Type I
20
3 — 453 — 56
Redundant - Single Stage
Hot Surface IgnitionMultiport Inshot
3115/1/60
9.1151/2
H x W x D41-3/4 x 19-1/2 x 30-1/2
155 / 145
TDC1B080A9421ADownflow / Horizontal
80,00074,00090.0
35 - 65DIRECT11 x 8
14
See Fan Performance Table1/2
1075115/1/60
CentrifugalDirect - 1
1/25 - 3200115/1/60
1.35No
High Velocity2 - 14x20 - 1in.
2 Round
Aluminized Steel - Type I
20
4 — 454 — 56
Redundant - Single Stage
Hot Surface IgnitionMultiport Inshot
4115/1/60
11.4151/2
H x W x D41-3/4 x 19-1/2 x 30-1/2
168 / 158
7Pub. No. 22-1670-04
GeneralData
1 Central Furnace heating designs are certified by the American Gas Association Inc. Laboratories.2 Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet; Ratings should be reduced at the rate of 4% for each 1000 feet above sea level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
MODELTYPERATINGS 22222Input BTUHCapacity BTUH (ICS) 33333AFUETemp. rise (Min.-Max.) °F.BLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HPR.P.M.Volts / Ph / HzCOMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLAFILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)VENT — Size (in.)HEAT EXCHANGERType-Fired
-UnfiredGauge (Fired)ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill SizeGAS VALVEPILOT SAFETY DEVICETypeBURNERS — TypeNumberPOWER CONN. — V / Ph / Hz 44444Ampacity (In Amps)Max Overcurrent Protection (Amps)PIPE CONN. SIZE (IN.)DIMENSIONSCrated (In.)WEIGHTShipping (Lbs.) / Net (Lbs)
PRODUCT SPECIFICATIONS 11111*DC1D120A9601A
Downflow / Horizontal
120,000110,000
90.040 - 70
DIRECT11 x 10
14
See Fan Performance Table1/2
1075115/1/60
CentrifugalDirect - 1
1/20 - 3450115/1/60
0.71No
High Velocity2 - 16x20 - 1in.
3 Round
Aluminized Steel - Type I
20
6 — 456 — 56
Redundant - Single Stage
Hot Surface IgnitionMultiport Inshot
6115/1/60
12.9151/2
H x W x D41-3/4 x 26-1/2 x 30-1/2
206 / 196
*DC1C100A9481ADownflow / Horizontal
100,00093,00090.0
35 - 65DIRECT11 x 10
14
See Fan Performance Table1/2
1075115/1/60
CentrifugalDirect - 1
1/20 - 3450115/1/60
0.71No
High Velocity2 - 16x20 - 1in.
2 Round
Aluminized Steel - Type I
20
5 — 455 — 56
Redundant - Single Stage
Hot Surface IgnitionMultiport Inshot
5115/1/60
12.5151/2
H x W x D41-3/4 x 23 x 30-1/2
185 / 175
8 Pub. No. 22-1670-04
PerformanceData
FURNACE AIRFLOW (CFM) VS. EXTERNAL STATIC PRESSURE (in. w.c.)
MODEL SPEED TAP 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90
TDC1B040A9241A 4 -3 -2 -1 -
HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red
998856753647
965832728617
922797694581
870751650538
807695596490
735628533435
653550460375
561462378308
459363286235
TDC1B060A9361A 4 -3 -2 -1 -
HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red
134111981369784
128511611232781
122311151108767
11561060998741
1082996901703
1004923817654
919842747593
829751689521
734652645437
TDC1B080A9421A 4 -3 -2 -1 -
HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red
1547148713881263
1498143613481234
1445138213021196
1386132512491150
1323126511911095
1254120211261032
118011371056960
11011069979879
1016998896790
TDC1C100A9481A 4 -3 -2 -1 -
HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red
1892177916301444
1827172615871416
1762167215441388
1688160514851348
1614153814261308
1531146013621246
1448138112971184
1354129112081108
1260120011191032
TDC1D120A9601A 4 -3 -2 -1 -
HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red
2213205717651468
2138200017331452
2062194317001435
2001188316521409
1939182216031382
1863175215521336
1786168115001290
1706159514241225
1625150813471159
CFM VS. TEMPERATURE RISE
MODELCubic Feet Per Minute (CFM)
600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400
TDC1B040A9241A 56 48 42 37 34
TDC1B060A9361A 63 56 51 46 42 39 36 34
TDC1B080A9421A 61 56 52 48 45 42 40 37 35
TDC1C100A9481A 65 60 56 53 50 47 44 42 40 38 37 35
TDC1D120A9601A 67 63 59 56 53 51 48 46 44 42
9Pub. No. 22-1670-04
SCHEMATIC DIAGRAMS FOR GAS FURNACES
ElectricalData
10 Pub. No. 22-1670-04
SCHEMATIC DIAGRAMS FOR GAS FURNACES
ElectricalData
11Pub. No. 22-1670-04
FieldWiring
FIELD WIRING DIAGRAM FOR HEATING ONLY
From Dwg.. 21B340388 Rev. 1
FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING/COOLING(OUTDOOR SECTION WITHOUT TRANSFORMER)
From Dwg.. 21B340387 Rev. 1
TO 115 V 1 PH.,60 HZ., POWERSUPPLY PERLOCAL CODES
HUM SEENOTE 5
EAC SEENOTE 5
TO 115 V 1 PH.,60 HZ., POWERSUPPLY PERLOCAL CODES
HUM SEENOTE 5
EAC SEENOTE 5
12 Pub. No. 22-1670-04
FieldWiring
From Dwg.. 21B341423 Rev. 1
From Dwg.. 21B341422 Rev. 1
13Pub. No. 22-1670-04
Dimensions
TDC1 OUTLINE DRAWING(ALL DIMENSIONS ARE IN INCHES)
From Dwg. 21C340462 Rev. 6
MODEL A B C D
TDC1B040A9241ATDC1B060A9361ATDC1B080A9421A
17-1/2" 2-1/4" 16-1/4" 16"
TDC1C100A9481A 21" 2-1/2" 19-3/4" 19-1/2"
TDC1D120A9601A 24-1/2" 2-15/16" 23-1/4" 23"
Since The Trane Company has a policy of continuous product and product data improvement, it reserves theright to change design and specifications without notice.
Trane
A business of American Standard companies6200 Troup HighwayTyler, TX 75707www.trane.com
File No. PL-UN-FURN-TDD-D-1 3/98 P.I. 04/07
Supersedes TDD-D-1 8/95