training pathfast® training belo horizonte, june 16, 2011
TRANSCRIPT
![Page 1: Training PATHFAST® Training Belo Horizonte, June 16, 2011](https://reader035.vdocuments.us/reader035/viewer/2022062511/5519edb05503464c588b4594/html5/thumbnails/1.jpg)
PATHFAST® Training
Belo Horizonte, June 16, 2011
![Page 2: Training PATHFAST® Training Belo Horizonte, June 16, 2011](https://reader035.vdocuments.us/reader035/viewer/2022062511/5519edb05503464c588b4594/html5/thumbnails/2.jpg)
Characteristics
• Compact immunoanalyzer• Full Automation• Whole blood, plasma, serum• Multi item processing ( up to six)• Short Assay Time ( 17 minutes)• Easy to Use• Hight Sensitivity / Acccuracy/ Reproducibility• Wide Dinamic Range• Minimun Cross Contamination• Barcode Control• Sample Recognition sensor
![Page 3: Training PATHFAST® Training Belo Horizonte, June 16, 2011](https://reader035.vdocuments.us/reader035/viewer/2022062511/5519edb05503464c588b4594/html5/thumbnails/3.jpg)
YYY
Whole Blood / Plasma
Chemilumi
Substrate
477nm
PMT
Calculator
Immunoreaction 5 min
YALP
YALP YALP
YA LP
YALPYALP
YY
Y
YALP
YALP
YALP
YY
YALP
YALP
YALP
Y
Enzyme Reaction
1min
Measure Light
Emission
BF washing
AnalyteContaminant
ALP Conjugate
Magnetic Particles
CDP-Star
PATHFAST® Assay Protocol
![Page 4: Training PATHFAST® Training Belo Horizonte, June 16, 2011](https://reader035.vdocuments.us/reader035/viewer/2022062511/5519edb05503464c588b4594/html5/thumbnails/4.jpg)
Each kit contains; Reagent cartridges (6 cartridges x 10 boxes)Calibrators (2 levels x 2 bottles)Calibrator Diluents ( 4 tubes) …for cTnI, CK-MB, D-DimerPackage Insert (IFU) & MC Entry Card*Stored at 2 to 8 ℃
Kits
![Page 5: Training PATHFAST® Training Belo Horizonte, June 16, 2011](https://reader035.vdocuments.us/reader035/viewer/2022062511/5519edb05503464c588b4594/html5/thumbnails/5.jpg)
Sample Well
■Magnetic particles■ALP conjugate■Chemilumin. Substrate (CDP-Star with SapphireII)●Sample Diluent●Washing Buffer
■■
■
●●●
●
Detection Well
Reagent Cartridge
![Page 6: Training PATHFAST® Training Belo Horizonte, June 16, 2011](https://reader035.vdocuments.us/reader035/viewer/2022062511/5519edb05503464c588b4594/html5/thumbnails/6.jpg)
Reagent Cartridge
Assay item
Lot number
Lot expiration
Detection well
Sample well
Cartridge Serial Number
![Page 7: Training PATHFAST® Training Belo Horizonte, June 16, 2011](https://reader035.vdocuments.us/reader035/viewer/2022062511/5519edb05503464c588b4594/html5/thumbnails/7.jpg)
Calibrators & ControlsCalibrators & Calibrator Diluents are included.
Controls are not included.MKI suggests users to use Biorad controls.PATHFAST data are described in package insert ofBiorad controls.
![Page 8: Training PATHFAST® Training Belo Horizonte, June 16, 2011](https://reader035.vdocuments.us/reader035/viewer/2022062511/5519edb05503464c588b4594/html5/thumbnails/8.jpg)
PATHFAST®DisposablesPATHFAST TIP PATHFAST Waste Box
Use one per test(42 tips x 5 boxes / Carton)
Change once a week(10 boxes / package)
Printer Roll Paper
(10 rolls / package)
![Page 9: Training PATHFAST® Training Belo Horizonte, June 16, 2011](https://reader035.vdocuments.us/reader035/viewer/2022062511/5519edb05503464c588b4594/html5/thumbnails/9.jpg)
4. PATHFAST® Components
![Page 10: Training PATHFAST® Training Belo Horizonte, June 16, 2011](https://reader035.vdocuments.us/reader035/viewer/2022062511/5519edb05503464c588b4594/html5/thumbnails/10.jpg)
Critical Care Immunology Analyzer
manufactured on the basis of an outstanding engineering experience
and excellent and well known reagent quality of Mitsubishi.
PATHFAST®