    Air conditioning system

  • 7/31/2019 Train Air Conditioing System

    2/29

    Why air conditioning ???

    Becoz human feels comfort only with somespecified parameter of temperature , humidity &purity & distribution of air in the occupied area , but

    outside condition is variable & doesnt fulfill therequirement.

  • 7/31/2019 Train Air Conditioing System

    3/29

    to control temperature

    to control humidity

    to supply pure air

    to distribute air properly

    Remove co2 from occupied area

    .

    Function of air conditioning system

  • 7/31/2019 Train Air Conditioing System

    4/29

    Component of air

    conditioning systemAir Transfer Equipment ( supply &

    distribution of air in the occupied area)

    Refrigeration system ( to control thetemperature & humidity of air to be supplied

    in the occupied zone)

    Electrical Equipments &controls ( tosupply electrical power supply & controlling

    all the equipments.

  • 7/31/2019 Train Air Conditioing System

    5/29

    Condenser

    Coils

    Condenser

    Fans

    Compressor

    Compartment

    Evaporator

    CompartmentSupply Air

    Blowers

    Return Air Compartment

    Main component

    Emergency

    inverter

  • 7/31/2019 Train Air Conditioing System

    6/29

    SUPPLYAIR

    RETURN

    AIR

    RETURN

    AIR

    ELEC.CUBICLE

    sight glass

    Supply fan

    condenser

    Condenserfan

    compressor

    Air conditioning System

  • 7/31/2019 Train Air Conditioing System

    7/29

    Air transfer System

    . S .

    S .

    saloon

    Evaporator

    Fresh air

    Fresh air

    Fresh airdamper

    Returnair

    RATFAT

    Supplyfan Supply

    fan

    filter Air toatmosphere

    NextAC

    . S .

    S .

  • 7/31/2019 Train Air Conditioing System

    8/29

    High pressure very high temp. vapour

    High pressure high temp. liquid

    Very Low temp. Low pressuremixture of liquid. & vapour

    Low temp. low pressure . vapour

    evaporator

    Compressor

    Condenser

    DPC

    T-X v/v

    Sightglass

    Filterdrier

    Supplyfan

    condenser fan

    Refrigeration system

    Solenoidv/v

  • 7/31/2019 Train Air Conditioing System

    9/29

    Refrigeration cycle

    T4

    T2

    T3

    Temp.

    entropy

    1

    2

    23

    4

    1

    1-2:- compression

    2-3 desuperheating

    & condensation

    3-4 expansion

    4-1 evaporation &superheatingT1

  • 7/31/2019 Train Air Conditioing System

    10/29

    Electrical system

  • 7/31/2019 Train Air Conditioing System

    11/29

    Electrical system

  • 7/31/2019 Train Air Conditioing System

    12/29

    Power circuit

  • 7/31/2019 Train Air Conditioing System

    13/29

    Control circuit

  • 7/31/2019 Train Air Conditioing System

    14/29

    Programmable Logic Controller

    INPUT

    1. Circuit breaker status

    2. High low pressurecondition

    3. Emergency condition

    4. Smoke condition

    5. Fresh return airtemperature

    6. Compressor motorwinding temperature

    OUTPUT

    1. Mode of working

    2. Contactors

    energizing3. Damper motor

    opening

    4. Solenoid valve on /off

    5. Unloader on / off

    6. Event & datalogging

    PLC

    TIMS

  • 7/31/2019 Train Air Conditioing System

    15/29

    Normal Operating Mode

    In Normal Operating Mode A/C unit provides cooling and

    ventilation, switching automatically by various sub modes to

    fulfil specified condition.

    Emergency Operating Mode

    When 3Ph. Power supply is not available , ac will work in this

    mode & will supply fresh air only..

    Smoke Mode

    In this mode , system shuts off the fresh air intake and provides

    full recirculation of return air within the saloon.

    Operating modes

  • 7/31/2019 Train Air Conditioing System

    16/29

    Normal operating sub -modes

    Vent mode :-air is supplied inside saloon without any cooling .

    COOL2

    COOL2

    TEMPERATURE

    FALLING

    TEMPERATURE

    RISING

    COOL1

    COOL1

    VENT

    VENT

    SET POINT

    SET POINT +1CO

    SET POINT

    Set Point + 0.5Co

    Set Point + 0.5C

    Set Point + 1.0C

    Cool-1 mode:-

    air is supplied with cooling(only 50% of cooling capacity

    is used)

    Cool-2 mode:-air is supplied with cooling(100% cooling capacity isused.

    24.00 C

    24.50 C

    250 C

  • 7/31/2019 Train Air Conditioing System

    17/29

    Different faults Circuit breaker tripping i.e SFB , CBF , CMB tripping:anycircuit breaker gets trips, this fault comes.

    CBF-1 or 2 tripped:- system will run as usual with increased discharge pressure

    CFB- 1&2 tripped :- system will not run in cool mode

    CMB tripped:- system will not run in cool mode

    SFB mode:- system will not run in a any mode

    High pressure(HP) fault:-when system pressure increase beyond givensafe limit for the system, then system gets tripped. If such instances occur more

    than 3times in a hours, then cooling system will shut down.

    Low pressure fault:when system pressure decreases beyond given safelimit for the system, cooling system will shut down.

  • 7/31/2019 Train Air Conditioing System

    18/29

    Different faults

    High ambient temperature unloading.:-in case of adverse ambientcondition , to avoid overloading of cooling system , system is unloaded.

    RAT/FAT probe fault:-these faults occurs in case of failure of temperatureprobe.

    COTS / IAOT getting operated:-these are temperature switches ,installed inside compressor motor winding & inverter area respectively., & getsoperated when temperature exceeds the given limit.& respective system gets

    shutdown.

  • 7/31/2019 Train Air Conditioing System

    19/29

    Cab air conditioning

    Capacity:- 5 KW

    Single rotary compressor

    Single condenser fan

    3 Different temperature set point

    Manual selection of operating mode

    Back mode facility in case of failure

  • 7/31/2019 Train Air Conditioing System

    20/29

    1. CompressorThe function of the compressor is to pump the refrigerant

    through the system and to compress the low pressure, lowtemperature refrigerant into a high pressure high temperature

    super heated vapour, to allow condensing to occur.

    Type:- Semi-Hermetic Four Cylinder

    Reciprocating Suction Gas Cooled

    Speed:- 1450 rpm

    Swept volume:- 82.21 m3/h

    Displacement:- 945 ccm

  • 7/31/2019 Train Air Conditioing System

    21/29

    2. CondenserThe function of the condenser coil is to reject the heat

    from refrigerant absorbed by the evaporator coil and

    during the compression process

    Type: Copper finned, copper tube,

    brass frame heat exchanger

    Quantity: 2 per unitAir Flow: 2700 l/s (each coil)

  • 7/31/2019 Train Air Conditioing System

    22/29

    3. T-X valveThe TX valve regulates the refrigerant flow into the

    evaporator coil, expanding the liquid from high pressure to

    low pressure, and causing a large drop in refrigerant

    temperature.

    Refrigerant R22

    Factory Superheat 5 K

    Max bulb temp. 100 o C

    Max working pressure 28bar

  • 7/31/2019 Train Air Conditioing System

    23/29

    4. Evaporator coilThe prime function of the evaporator compartment

    is to deliver conditioned air to the main supply air

    duct that services the vehicle

    Type: Copper finned, copper tube,

    brass frame heat exchanger.

    Quantity: 1 per unit.

    Air Flow: 1350 l/s

    Face Velocity: 2.5 m/s

    Cooling Capacity: 41 kW

  • 7/31/2019 Train Air Conditioing System

    24/29

    5. Dual pressure controller (DPC)

    Its function is to switch off the refrigeration system in caseof adverse system condition . It monitors both the high and

    low refrigerant pressures. If the low (LP) or high (HP)

    pressures reach a predetermined set point, the refrigeration

    system will be shut down.

    Range: LP 50 700 kPa

    HP 300 3000 kPa

    Set points:-

    hp fault:- 2800 / 2500 kpa

    Lp fault :- 50/350 kpa

  • 7/31/2019 Train Air Conditioing System

    25/29

    Type: Two double inlet centrifugal blower

    wheels with double shafted motor

    Quantity: Two (2) per unit

    Supply Air: 1350 Litres/second at 470 Paexternal static pressure

    Motor:- 2.2 kw @1500rpm , 415 v

    Supply fanAs the name applies , itsupplies the conditioned airinside saloon . It draws back70% of return air & 30% of

    fresh air & moves past t

  • 7/31/2019 Train Air Conditioing System

    26/29

    Condenser fan

    Type: Multi wing axial fan, 9 blades

    Quantity: two (2) per unit

    Direction of flow: Draw through

    RPM Range: 0 2045 rpm

    Motor:- 2.2 KW @1500rpm , 415 v

    Its function is draw theatmospheric air throughcondenser coil , inside whichhot refrigerant is flowing ,

    thus making the heatrejection & condensing the

  • 7/31/2019 Train Air Conditioing System

    27/29

    Fresh Air

    Damper Motor

    Fresh Air Damper

    Air dampers

    Return Air Damper

    Their function is to control the fresh air & return( recirculated) air volume as per requirement.

    Mode fresh air return air

    damper damper

    Vent , partially fully

    Cool 1 &2 opened opened

    Emergency fully fullyvent opened closed

    Smoke fully fully

    vent closed Opened

  • 7/31/2019 Train Air Conditioing System

    28/29

    Electrical cubicle

    PLC

    CMB, SFB,CFB , DCB ,

    EIVCB

    CMC, SFC,CFC, ESFC