towards a sustainable future???? - iglootech · 2016-02-11 · poliuretan spray . pu spray foam low...

16
A green and healthy future through Spray Foam Low Global Warming Potential & Radon Gas Barrier S-35RGB/ECO ELMICO – Norway, 14 th January 2016 By Roberto García Area Manager

Upload: others

Post on 27-Jul-2020

2 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Towards a sustainable future???? - IglooTech · 2016-02-11 · Poliuretan Spray . PU Spray Foam Low GWP & Radon Gas Barrier Test and Certification: Only 3 laboratories in Europe (Czech

A green and healthy future through

Spray Foam Low Global Warming Potential

& Radon Gas Barrier S-35RGB/ECO

ELMICO – Norway, 14th January 2016

By Roberto García Area Manager

Page 2: Towards a sustainable future???? - IglooTech · 2016-02-11 · Poliuretan Spray . PU Spray Foam Low GWP & Radon Gas Barrier Test and Certification: Only 3 laboratories in Europe (Czech

Blowing Agent in Polyurethane Foams

2

History and situation about Blowing Agents

Poliuretan S Spray

Page 3: Towards a sustainable future???? - IglooTech · 2016-02-11 · Poliuretan Spray . PU Spray Foam Low GWP & Radon Gas Barrier Test and Certification: Only 3 laboratories in Europe (Czech

A green & healthy future through

Poliuretan S Spray S-35RGB/ECO

Radon Gas Barrier & LGWP

3

Page 4: Towards a sustainable future???? - IglooTech · 2016-02-11 · Poliuretan Spray . PU Spray Foam Low GWP & Radon Gas Barrier Test and Certification: Only 3 laboratories in Europe (Czech

PU Spray Foam Low GWP & Radon Gas Barrier

4

Poliuretan S Spray HFO. Not HFC: S-35RGB/ECO

Poliuretan Spray

• Free density: 34 + 2 kg/m3

• Applied density from (UNE-EN 1602) : 38 to 48 kg/m3

• Close Cell Content (ISO 4590): > 90% & (CCC4)*

• Thermal Conductivity Coeff. (l) (EN-12667): 0.020 – 0.027W/m K

• Compressive strength (EN 826): 150-250 kPa & CS(10\Y)150*

• Dimensional Stability (EN 1604): < 6% ((70 ± 2) °C and (90 ± 5) % r.h.) & DS (TH)3*

• Reaction to fire (EN 13501-1): Euroclass E

(*) Product Standard EN-14315

Page 5: Towards a sustainable future???? - IglooTech · 2016-02-11 · Poliuretan Spray . PU Spray Foam Low GWP & Radon Gas Barrier Test and Certification: Only 3 laboratories in Europe (Czech

PU Spray Foam Low GWP & Radon Gas Barrier

5

PRODUCT STANDARD EN-14315

Poliuretan Spray

Page 6: Towards a sustainable future???? - IglooTech · 2016-02-11 · Poliuretan Spray . PU Spray Foam Low GWP & Radon Gas Barrier Test and Certification: Only 3 laboratories in Europe (Czech

PU Spray Foam Low GWP & Radon Gas Barrier

What is Radon Gas?

• Chemical element radiaoctive and gaseous

• Granite origin, granite areas, mining.

• From U238 and Ra226 (solids) Rd222 (Gas)

6

Poliuretan S Spray S-35RGB/ECO Barrier Against Radon Gas

Poliuretan S Spray

Page 7: Towards a sustainable future???? - IglooTech · 2016-02-11 · Poliuretan Spray . PU Spray Foam Low GWP & Radon Gas Barrier Test and Certification: Only 3 laboratories in Europe (Czech

PU Spray Foam Low GWP & Radon Gas Barrier

What is the main problem?

• In the atmosphere the low concentration of Rd is not a problem

• Confined spaces HOUSES, concentration could be HIGHER

Why?

Inhalation of Radon (Po218 and Po214) Alpha Particles

• Provokes LUNG CANCER

• USA consideres 2nd cause of Lung Cancer after smoking

• In Europe: Germany, France, Sweden, Holland, Spain, ….

» In 1987 (EPA) and 1988 (IARC):

Radon Gas was declared a Human Carcinogen 7

Poliuretan S Spray S-35RGB/ECO

Poliuretan S Spray

Page 8: Towards a sustainable future???? - IglooTech · 2016-02-11 · Poliuretan Spray . PU Spray Foam Low GWP & Radon Gas Barrier Test and Certification: Only 3 laboratories in Europe (Czech

PU Spray Foam Low GWP & Radon Gas Barrier

How to solve it?

• Waterproof membrane or barrier against Rd gas.

• Penetration Control. How much? Diffusion Coefficient of Gas Rd.

D= 10-15 - 10-8 m2/s.

• Diffusion Length (mm) L. German Standard states:

The thickness of barrier must be 3 x L in order to guarantee < 1-2 % atoms.

Requirements from Europe:

Recommendation is 400 Bq/m3

New houses built are 200 Bq/m3 (EPA in USA says 148 Bq/m3)

WHO: Goal is 100 Bq/m3

8

Poliuretan S Spray S-35RGB/ECO

Poliuretan Spray

Page 9: Towards a sustainable future???? - IglooTech · 2016-02-11 · Poliuretan Spray . PU Spray Foam Low GWP & Radon Gas Barrier Test and Certification: Only 3 laboratories in Europe (Czech

PU Spray Foam Low GWP & Radon Gas Barrier

Test and Certification:

Only 3 laboratories in Europe (Czech Rep., Spain and Sweden).

Tested: Spain LaRUC (UC) & Sweden SP Technical Research Inst. Lower Chambre: Flow into 10000+ 2000 Bq/m3 h

Concentation > 1,000,000 Bq/m3 (3 days)

Upper Chambre: Testing Area

9

Poliuretan S Spray S-35RGB/ECO

Poliuretan Spray

Page 10: Towards a sustainable future???? - IglooTech · 2016-02-11 · Poliuretan Spray . PU Spray Foam Low GWP & Radon Gas Barrier Test and Certification: Only 3 laboratories in Europe (Czech

PU Spray Foam Low GWP & Radon Gas Barrier

Test and Certification:

10

Poliuretan S Spray S-35RGB/ECO

Poliuretan S Spray

Thickness= 30 mm D= 3.2 10 -11 – 1,4 10 -10 m2/s L = 2.5 (30) – 11.2 (100) mm C = 1.1 MBq/m3 vs 23-200Bq/m3

D= < LD L = 0.3 – 1 (30-35) mm C = 1.3 MBq/m3 vs 8 Bq/m3

Page 11: Towards a sustainable future???? - IglooTech · 2016-02-11 · Poliuretan Spray . PU Spray Foam Low GWP & Radon Gas Barrier Test and Certification: Only 3 laboratories in Europe (Czech

PU Spray Foam Low GWP & Radon Gas Barrier

11

Poliuretan S Spray S-35RGB/ECO. Certifications (Spain)

Poliuretan S Spray

Page 12: Towards a sustainable future???? - IglooTech · 2016-02-11 · Poliuretan Spray . PU Spray Foam Low GWP & Radon Gas Barrier Test and Certification: Only 3 laboratories in Europe (Czech

PU Spray Foam Low GWP & Radon Gas Barrier

Test and Certification:

Sweden: SP Technical Research Institute of Sweden. Source Chambre: Flow into 22000 until 28000 Bq/m3 h (a week)

Thickness: 20 mm Thickness: 100 mm

12

Poliuretan S Spray S-35RGB/ECO

Poliuretan Spray

Page 13: Towards a sustainable future???? - IglooTech · 2016-02-11 · Poliuretan Spray . PU Spray Foam Low GWP & Radon Gas Barrier Test and Certification: Only 3 laboratories in Europe (Czech

PU Spray Foam Low GWP & Radon Gas Barrier

Test and Certification:

13

Poliuretan S Spray S-35RGB/ECO

Poliuretan S Spray

Thickness = 20 mm D= < 5 10 -9 m2/s C = 25000 Bq/m3 vs 50 Bq/m3

Thickness = 100 mm D= < 5 10 -9 m2/s C = 25000 Bq/m3 vs 48 Bq/m3

Page 14: Towards a sustainable future???? - IglooTech · 2016-02-11 · Poliuretan Spray . PU Spray Foam Low GWP & Radon Gas Barrier Test and Certification: Only 3 laboratories in Europe (Czech

PU Spray Foam Low GWP & Radon Gas Barrier

14

Poliuretan S Spray S-35RGB/ECO. Certifications (Sweden)

Poliuretan S Spray

Page 15: Towards a sustainable future???? - IglooTech · 2016-02-11 · Poliuretan Spray . PU Spray Foam Low GWP & Radon Gas Barrier Test and Certification: Only 3 laboratories in Europe (Czech

PU Spray Foam Low GWP & Radon Gas Barrier

* New Spray System in the market without HCFC and HFC. * Application LIKE Spray Systems currently. * CE Mark in process. * Thermal Insulation Coeff. (l) 0,020 - 0,027 W/m K * Waterproofing System (> 90%, CCC4) * Barrier againts Radon Gas difussion * Continuo System. Not thermal bridge.

POLIURETAN S SPRAY S-35RGB/ECO A GREEN AND HEALTHY SOLUTION FOR INSULATING.

15

Poliuretan S Spray S-35RGB/ECO Summary:

Poliuretan S Spray

Page 16: Towards a sustainable future???? - IglooTech · 2016-02-11 · Poliuretan Spray . PU Spray Foam Low GWP & Radon Gas Barrier Test and Certification: Only 3 laboratories in Europe (Czech

A future through

16

Poliuretan S Spray S-35RGB/ECO

THANK YOU TAKK & TACK