touch control d ata loggerfile.yizimg.com/384687/2012101016314751.pdf · touch control d ata logger...

12
深圳市拓普瑞电子有限公司 SHEN ZHEN TOPRIE ELECTRONIC CO.,LTD Touch Touch Touch Touch control control control control Data ata ata ata Logger ogger ogger ogger Completely Completely Completely Completely new new new new concept concept concept concept of of of of networking networking networking networking– to to to to open open open open the the the the era era era era of of of of intelligent intelligent intelligent intelligent devices! devices! devices! devices! Data Data Data Data collection, collection, collection, collection, monitoring, monitoring, monitoring, monitoring, recording recording recording recording and and and and control control control control could could could could be be be be easily easily easily easily realized. realized. realized. realized. Multi-purpose Multi-purpose Multi-purpose Multi-purpose tests tests tests tests (voltage, (voltage, (voltage, (voltage, electric electric electric electric current current current current, temperature, temperature, temperature, temperature, pressure, pressure, pressure, pressure, vibration, vibration, vibration, vibration, frequency frequency frequency frequency band band band band and and and and flow flow flow flow rate, rate, rate, rate, etc) etc) etc) etc) Channel Channel Channel Channel of of of of single single single single machine machine machine machine 8-64 8-64 8-64 8-64 could could could could be be be be freely freely freely freely assembled. assembled. assembled. assembled. Several Several Several Several communication communication communication communication methods methods methods methods like like like like RS232, RS232, RS232, RS232, RS485, RS485, RS485, RS485, USB, USB, USB, USB, GPIB GPIB GPIB GPIB and and and and Ethernet Ethernet Ethernet Ethernet TP1000/TP700 TP1000/TP700 TP1000/TP700 TP1000/TP700 Customer service phone: 4000428882 or login to our website: WWW.TOPRIE.COM

Upload: others

Post on 19-Jun-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

深圳市拓普瑞电子有限公司SHEN ZHEN TOPRIE ELECTRONIC CO.,LTD

TouchTouchTouchTouch controlcontrolcontrolcontrol DDDDataataataata LLLLoggeroggeroggerogger

CompletelyCompletelyCompletelyCompletely newnewnewnew conceptconceptconceptconcept ofofofof networkingnetworkingnetworkingnetworking–––– totototo openopenopenopen thethethethe eraeraeraera ofofofof intelligentintelligentintelligentintelligent devices!devices!devices!devices! DataDataDataData

collection,collection,collection,collection, monitoring,monitoring,monitoring,monitoring, recordingrecordingrecordingrecording andandandand controlcontrolcontrolcontrol couldcouldcouldcould bebebebe easilyeasilyeasilyeasily realized.realized.realized.realized.

Multi-purposeMulti-purposeMulti-purposeMulti-purpose teststeststeststests (voltage,(voltage,(voltage,(voltage, electricelectricelectricelectric currentcurrentcurrentcurrent,,,, temperature,temperature,temperature,temperature, pressure,pressure,pressure,pressure, vibration,vibration,vibration,vibration,

frequencyfrequencyfrequencyfrequency bandbandbandband andandandand flowflowflowflow rate,rate,rate,rate, etc)etc)etc)etc)

ChannelChannelChannelChannel ofofofof singlesinglesinglesingle machinemachinemachinemachine 8-648-648-648-64 couldcouldcouldcould bebebebe freelyfreelyfreelyfreely assembled.assembled.assembled.assembled. SeveralSeveralSeveralSeveral communicationcommunicationcommunicationcommunication methodsmethodsmethodsmethods

likelikelikelike RS232,RS232,RS232,RS232, RS485,RS485,RS485,RS485, USB,USB,USB,USB, GPIBGPIBGPIBGPIB andandandand EthernetEthernetEthernetEthernet

TP1000/TP700TP1000/TP700TP1000/TP700TP1000/TP700

Customer service phone: 4000428882 or login to our website:

WWW.TOPRIE.COM

深圳市拓普瑞电子有限公司SHEN ZHEN TOPRIE ELECTRONIC CO.,LTD

USB -1068 PC recorder

TP700 7” Display Data Logger

TP1000 10.1” Display Data Logger

深圳市拓普瑞电子有限公司SHEN ZHEN TOPRIE ELECTRONIC CO.,LTD

Product Features

8 colorful pictures could be indicated

TheTheTheThe thinnestthinnestthinnestthinnest andandandand lightestlightestlightestlightest oneoneoneone inininin thethethethe industryindustryindustryindustry

EnvironmentEnvironmentEnvironmentEnvironment performanceperformanceperformanceperformance IP65IP65IP65IP65Review and approval of environment criterion IP65 was obtained. According to different conditions of the logger, some might be

exposed to oil, dust and water, etc, while TP series data logger can be used in these conditions.

MeasurementMeasurementMeasurementMeasurement unitunitunitunit whichwhichwhichwhich cancancancan bebebebe addedaddedaddedaddedThe input can be a unit category which can be added at intervals of 8ch. The

waste of space can be avoided as per the applied frequency band quantities and

framework system. A case can be extended to 8 units (64ch) as a maximum. 4

cases can use one display case as a maximum and be extended to 256CH.

Moreover, we will flexibly provide the service of change to design after the sales. In

addition, the measurement unit can not only be dismantled, also the port desk can

be dismantled from its structure, so the time of setting and wiring will be saved.

深圳市拓普瑞电子有限公司SHEN ZHEN TOPRIE ELECTRONIC CO.,LTD

InputInputInputInput andandandand outputoutputoutputoutput ofofofof controlcontrolcontrolcontrolI/O unit of input 8ch and output 8ch can be added and extended to

4 units at the most, and 8 units for a single input. The input port can be

used as pulse measurement frequency band or control input for

external start/stop.

SimpleSimpleSimpleSimple andandandand effectiveeffectiveeffectiveeffective storagestoragestoragestorage

TP series management software uses communication methods of The Ethernet, GPIB and Zigbee and TP series

instrumentations for communication. The collected data indicate on the PC in curves and data lists. (Standard configuration

RS232, others can be selected)

LargeLargeLargeLarge capacitycapacitycapacitycapacity memorymemorymemorymemoryTP series logger configures 70MB large capacity memory, which could effectively support data collection for multi frequency

bands for a long time. After the memory is full, the oldest data will start circle and be covered and saved, so the newest documents

will be saved.

Storage for data

As long as the U disk is inserted to the TP series logger, the data can be saved in the U

disk by setting the start time and end time. Therefore, there is no need for the replacement

of figure logging paper and troublesome button pressing on the traditional data logger.

Flexible operation

The device could flexibly supply the service of change to design for your company. The

measurement unit can not only dismantle and install the input/output module; also the port

desk can be dismantled from the structure, so the time for setting and wiring will be saved.

The hot plug is supported (i.e. the measurement unit module can be directly plugged during

power-on), so it is very convenient for operation.

深圳市拓普瑞电子有限公司SHEN ZHEN TOPRIE ELECTRONIC CO.,LTD

Preview and analysis for historical data

The collected historical data can be previewed and analyzed in curves and lists.

The curve preview includes the zooming of the curve and the selection of channel display. The data analysis includes

compilation, document merging and data printing.

Data printing

The data can be printed in curves or lists to meet various customers’ requirements.

深圳市拓普瑞电子有限公司SHEN ZHEN TOPRIE ELECTRONIC CO.,LTD

Relying on its rich display pictures, flexible operation methods and powerful logging, calculation, controland management function, TP1000/TP1000/TP1000/TP1000/TPTPTPTP700700700700 seriesseriesseriesseries touchtouchtouchtouch datadatadatadata loggerloggerloggerlogger has achieved wide application invarious sectors. Adopting advantages of various domestic and overseas paperless loggers, applying thenewest display technology, micro-electronics technology, data storage and communication technology, thisproduct is multiple functional, easily operable, accurate, reliable and attractive in price and performance.

The configuration for this product is rich, so various direct current, voltage and resistance signals can bereceived to realize the display, recording, monitoring for out-of-limit, report generation, data communication,signal transmission and flow rate accumulation for temperature, pressure, liquid level, flow rate, elementphysical quantity like force, moment and displacement.

This product mainly consists of LCD, button, main board which takes ARM microprocessor as the core,main power, external transmitter power, intelligent channel plate and large capacity FLASH.

*Various types of intelligent channel plates can be configured, which could be selected as perapplication requirements.

*Large capacity FLASH is installed. The data in the FLASHA can be transferred and saved in thecomputer through U disk in a timely manner. The memory for the internal FLASH is 64M bytes. At 8channels, if a record is made at intervals of 20 seconds, then the records can last 865 days. Allchannel data could be recorded in 1 second in the quickest manner.

*Digital display picture, bar graph display picture, real-time curve picture, recall curve picture*Cursor function of recall curve reading.*Basic error for measurement and display: ±0.2% F·S

深圳市拓普瑞电子有限公司SHEN ZHEN TOPRIE ELECTRONIC CO.,LTD

*12 alarming functions can be configured.*8 transmitting outputs can be configured, optical isolation with the deviation less than ±0.2% F·S*Output for electric current (4~20) mA, selectable for (0~10) mA or (0~20) mA.Output for voltage (0~5) V, selectable for (1~5) V.The default setting at delivery is (4~20) mA. For other categories, please make notification in the order.

FunctionFunctionFunctionFunction featuresfeaturesfeaturesfeatures ofofofof TP1000/TP1000/TP1000/TP1000/TPTPTPTP700700700700 seriesseriesseriesseries touchtouchtouchtouch datadatadatadata loggerloggerloggerlogger

The product can indicate plenty of information with friendly interface and easy operation. The main function features are as

follows:

*Record can be made without pen and papers. Little daily maintenance is required. Operation expense is low.

*High brightness colorfulcolorfulcolorfulcolorful 10.1/710.1/710.1/710.1/7””””TFTLCDTFTLCDTFTLCDTFTLCD is used, CCFL back-lighted with clear pictures;

*ARM microprocessor is used. 64646464 channelchannelchannelchannel signalsignalsignalsignal collectioncollectioncollectioncollection, recording, indication and alarming can be realized at the

same time

*LargeLargeLargeLarge capacitycapacitycapacitycapacity 70707070 MBMBMBMB FLASHFLASHFLASHFLASH chipchipchipchip isisisis usedusedusedused to store historical data. The data will never lose even if the power is off.

*It is entirely isolated universal input. Several signals can be input simultaneously. There is no need to change the module.

It can be realized through software configurations.

*The data range which indicates quantities is wider. 5 numbers can be indicated: -9999~19999;

*It can be configured to indicate project item number, project unit and flow rate accumulation.

*Flash alarming is configured. It can indicate the alarming for lower limit, low limit, up limit and upper limit; 12 channels

relay alarming output;

*8 transmitted outputs can be configured with optical isolation and deviation less than ±0.2% F·S;

*Highly accurate in indication with basic deviation ±0.2% F·S;

*Temperature and pressure compensation supports compensation signal input and constant selection. Several

compensation models are provided, such as overheated steam, saturated steam, pressure compensation, etc.

*GB2312GB2312GB2312GB2312 ChineseChineseChineseChinese charactercharactercharactercharacter basebasebasebase isisisis installedinstalledinstalledinstalled inside.inside.inside.inside. Quanpin input method is used.

*Four/threeFour/threeFour/threeFour/three standardstandardstandardstandard USBUSBUSBUSB interfacesinterfacesinterfacesinterfaces are configured. U disk is used to store the historical data in a timely and easy

manner; the keyboard and mouse can be also connected;

*Standard serial communication interface with optical isolation of RS485 and RS232C;

*It supports standard ModBus RTU communication protocol (configured function). Other than supporting the data

management software of our company, it also supports popular configuration software like MCGS and configuration king,

etc.

*Famous high quality switch power is used. It can normally operate in the voltage range of AC 85V~265V;

*The transmitter DCDCDCDC 24V24V24V24V isolationisolationisolationisolation powerpowerpowerpower distributiondistributiondistributiondistribution isisisis supplied.supplied.supplied.supplied.

*EMCIII level is approved to ensure that the instrumentation can operate in severe conditions in a good condition.

TP1000/TP1000/TP1000/TP1000/TPTPTPTP700700700700 seriesseriesseriesseries touchtouchtouchtouch datadatadatadata loggerloggerloggerlogger indicationindicationindicationindication

*10.1/7”colorful TFT display*Totally 4 basic pictures, i.e. digital display, bar graph display, real-time curve picture and recall curve picture*Basic deviation less than ±0.2%F·S, digital indication range is -9999~19999*Measurement resolution power: 1/60000, 16 digits AD converter*Real-time curve record time intervals of 1 second ~9999 seconds can be set up, which corresponds to 30 seconds ~ 300minutes of display curve time*The recall curve record intervals is constantly set from 1 second ~9999 seconds

深圳市拓普瑞电子有限公司SHEN ZHEN TOPRIE ELECTRONIC CO.,LTD

TP1000/TP1000/TP1000/TP1000/TPTPTPTP700700700700 seriesseriesseriesseries touchtouchtouchtouch datadatadatadata loggerloggerloggerlogger signalsignalsignalsignal inputinputinputinput

The input signal includes DC, DC voltage, thermal resistance, thermoelectric couple and remote pressure gauge, whichcan be selected by pressing buttons; isolated universal input. The jumper is not required.

*DC current : (4~20) mA, (0~10)mA, (0~20)mA*DC voltage: (1~5) V, (0~5) V(0~10) V, (1~10) V*RTD: Pt100(three wires)*T/C:K,S,R,B,N,E,J,T,cu50*Other input signals or type of thermocouple and RTD should be notified in the order.

TP1000/TP1000/TP1000/TP1000/TPTPTPTP700700700700 seriesseriesseriesseries touchtouchtouchtouch datadatadatadata loggerloggerloggerlogger externalexternalexternalexternal powerpowerpowerpower supplysupplysupplysupply

DC 24V power supply: used to supply power for transmitter, maximum loading capacity ≤200mA; ((((lithiumlithiumlithiumlithium batterybatterybatterybattery cancancancan bebebebeselectedselectedselectedselected forforforfor powerpowerpowerpower supply)supply)supply)supply) forforforfor itititit isisisis easyeasyeasyeasy totototo carry.carry.carry.carry.

TP1000/TP1000/TP1000/TP1000/TPTPTPTP700700700700 seriesseriesseriesseries touchtouchtouchtouch datadatadatadata loggerloggerloggerlogger communicationcommunicationcommunicationcommunication printingprintingprintingprinting interfaceinterfaceinterfaceinterface (function(function(function(functionconfiguration)configuration)configuration)configuration)

*Optical isolation*RS232 and RS485 standard. For thethethethe interfaceinterfaceinterfaceinterface ofofofof TheTheTheThe EthernetEthernetEthernetEthernet please make notification in the order (function of TP1000series standard configuration)*Communication rate 9600, 19200, 57600 and 115200, they can be selected as per the setting.*The supporting testing software, configuration software and application software technical support are provided*Modbus RTU communication protocol can be selected to communicate with host computer

TP1000/TP1000/TP1000/TP1000/TPTPTPTP700700700700 seriesseriesseriesseries touchtouchtouchtouch datadatadatadata loggerloggerloggerlogger powerpowerpowerpower conditionconditionconditioncondition

*Instrumentation for AC 220V power supply: AC 85~265V, power consumption less than 25VA*Instrumentation for DC 24V power supply: 24V±10%, power consumption less than 25VANotes:Notes:Notes:Notes: ActualActualActualActual powerpowerpowerpower consumptionconsumptionconsumptionconsumption subjectssubjectssubjectssubjects totototo thethethethe modulemodulemodulemodule quantitiesquantitiesquantitiesquantities collectedcollectedcollectedcollected bybybyby thethethethe device.device.device.device.

TP1000/TP1000/TP1000/TP1000/TPTPTPTP700700700700 seriesseriesseriesseries touchtouchtouchtouch datadatadatadata loggerloggerloggerlogger environmentenvironmentenvironmentenvironment andandandand othersothersothersothers

*Working temperature range: 0℃~50℃*Storage temperature range: -20℃~70℃*Working humility range: less than 85%R.H, without condensation of moisture*Weight of the instrumentation: maximum around 2.8Kg

TP1000/TP1000/TP1000/TP1000/TPTPTPTP700700700700 seriesseriesseriesseries touchtouchtouchtouch datadatadatadata loggerloggerloggerlogger shapeshapeshapeshape andandandand sizesizesizesize ofofofof openingopeningopeningopening

*The wiring must be carried out after the power is off to ensure safety.*The (PG) port of the instrumentation supplied by AC is the public port of power line filter. It has high voltage and can onlybe connected to the ground. It is forbidden to connect it to other terminals.*The wiring chart in the manual is the basic wiring chart, which subjects to the quantities of terminals. In case of conflictbetween instrumentation function and basic wiring chart, the instructions of wiring chart shall prevail.

OverallOverallOverallOverall dimension:dimension:dimension:dimension: 288*288*182mm288*288*182mm288*288*182mm288*288*182mm (length(length(length(length **** widthwidthwidthwidth **** height)height)height)height)

SizeSizeSizeSize ofofofof openingopeningopeningopening installedinstalledinstalledinstalled:::: 278*278mm278*278mm278*278mm278*278mm

深圳市拓普瑞电子有限公司SHEN ZHEN TOPRIE ELECTRONIC CO.,LTD

InstallationInstallationInstallationInstallation chartchartchartchart forforforfor TP1000/TP1000/TP1000/TP1000/TPTPTPTP700700700700 seriesseriesseriesseries datadatadatadata logger,logger,logger,logger, thethethethe unitunitunitunit forforforfor thethethethe followingfollowingfollowingfollowing measurementmeasurementmeasurementmeasurement isisisis mmmmmmmm

深圳市拓普瑞电子有限公司SHEN ZHEN TOPRIE ELECTRONIC CO.,LTD

Application of the productTouch data loggerPerformancePerformancePerformancePerformance of application in automation and sensing

CollectCollectCollectCollect thethethethe datadatadatadata ofofofof temperaturetemperaturetemperaturetemperature andandandandhumilityhumilityhumilityhumility distributiondistributiondistributiondistribution ofofofof ACACACAC

CollectCollectCollectCollect thethethethe PH.PH.PH.PH. flowflowflowflow raterateraterate datadatadatadata ofofofof waterwaterwaterwatertreatmenttreatmenttreatmenttreatment facilitiesfacilitiesfacilitiesfacilities

ReducingReducingReducingReducing recordrecordrecordrecord forforforfor thethethethe consumptionconsumptionconsumptionconsumption ofofofofenergyenergyenergyenergy

CollectCollectCollectCollect thethethethe commutatecommutatecommutatecommutate andandandand dischargedischargedischargedischarge datadatadatadata ofofofofplatingplatingplatingplating bathbathbathbath

CollectCollectCollectCollect andandandand launchlaunchlaunchlaunch thethethethe temperaturetemperaturetemperaturetemperature andandandandODODODOD ofofofof processprocessprocessprocess

CollectCollectCollectCollect thethethethe ddddecontaminationecontaminationecontaminationecontamination andandandandsterilizationsterilizationsterilizationsterilization datedatedatedate ofofofof foodsfoodsfoodsfoods

深圳市拓普瑞电子有限公司SHEN ZHEN TOPRIE ELECTRONIC CO.,LTD

ControlControlControlControl thethethethe temperature,temperature,temperature,temperature, pressurepressurepressurepressure andandandandflowflowflowflow raterateraterate ofofofof boilerboilerboilerboiler

MeasureMeasureMeasureMeasure thethethethe temperaturetemperaturetemperaturetemperature inininin durationdurationdurationdurationtestingtestingtestingtesting

MeasureMeasureMeasureMeasure thethethethe moldingmoldingmoldingmolding temperaturetemperaturetemperaturetemperature ofofofof diediediediecastingcastingcastingcasting machinemachinemachinemachine

MeasureMeasureMeasureMeasure thethethethe vibrationvibrationvibrationvibration andandandand strainstrainstrainstrain inininin benchbenchbenchbenchtestingtestingtestingtesting ofofofof thethethethe engineengineengineengine

MeasureMeasureMeasureMeasure thethethethe vibrationvibrationvibrationvibration ofofofof drilldrilldrilldrill spindlespindlespindlespindle MeasureMeasureMeasureMeasure thethethethe vibrationvibrationvibrationvibration ofofofof powerpowerpowerpower pumppumppumppump

深圳市拓普瑞电子有限公司SHEN ZHEN TOPRIE ELECTRONIC CO.,LTD

ModelModelModelModelTP700TP700TP700TP700 seriesseriesseriesseries

TouchTouchTouchTouch datadatadatadata loggerloggerloggerloggerTP1000TP1000TP1000TP1000 seriesseriesseriesseries

TouchTouchTouchTouch datadatadatadata loggerloggerloggerloggerUSBUSBUSBUSB 1608160816081608

PCPCPCPC recorderrecorderrecorderrecorder

Display 7" TFT Color touchscreen 10.1" TFT Color touchscreen Without screenResolution 800*480 Pixels 800*480 Pixels /Number of channel(Input) 8ch to 64ch 8ch to 64ch 8chInput Type *mAdc:(4~20)mA,(0~10)

mA,(0~20)mA*Vdc:(1~5)V,(0~5V,(0~10)

V, (1~10) V*RTD: Pt100(3-wire)*TC:K,S,R,B,N,E,J,T,

cu50 etc

*mAdc:(4~20)mA,(0~10)mA,(0~20)mA*Vdc:(1~5)V,(0~5V,(0~10)

V, (1~10) V*RTD: Pt100(3-wire)*TC:K,S,R,B,N,E,J,T,

cu50 etc.

*mAdc:(4~20)mA,*Vdc: (1~5)V,*RTD: Pt100(3-wire)*TC:K,S,R,B,N,E,J,T,cu50 etc.

Math Function standard standard withoutEthernet capabilities No Yes No

Alarm relay Outputs 0-32 0-32 0-4Inbuilt memory 70M 70M Without(save data by

PC software)External storage media 1G/2G/3G/4G/8G etc USB disk 1G/2G/3G/4G/8G etc USB disk WithoutSampling period 1s to 9999s 1s to 9999s 1s to 9999sCommunication RS-232C/USB/RS-485/GPIB/Zi

gbee/GPRS(Standardconfiguration RS232, otherscan be selected)

RS-232C/USB/RS-485/GPIB/Zigbee/GPRS/Ethernet (Standardconfiguration RS232 andEthernet , others can beselected)

RS485 /GPRS/USB/Zigbee/(Standardconfiguration USB,others can beselected)

Screen display Digital display picture, bargraph display picture,real-time curve picture, recallcurve picture

Digital display picture, bargraph display picture, real-timecurve picture, recall curvepicture

Digital display picture,real-time curvepicture, recall curvepicture (through thePC software)

Printing function Optional Optional WithoutMeasurement range Depends on input Depends on input Depends on inputPower supply AC 220V (85-265V) AC 220V (85-265V) DC 10-30VAccuracy ±0.2% F·S ±0.2% F·S ±0.2% F·S

Sensor supply DC 24V+-10% DC 24V +-10% DC 24V+-10%

Storage temperature -20℃~70℃ -20℃~70℃ -10℃~70℃

Operating temperature 0℃~50℃ 0℃~50℃ -25℃~50℃

Storage humidity ≤85%R.H(no condensate) ≤85%R.H(no condensate) ≤95%R.H(no condensate)

Size 288*288*144mm 288*288*144mm 110*75*25mmInstallation size 278*278mm 278*278mm No