total system graph 3 - energysave.se · wood /pellets boiler total system graph 3 tap water solar...

12
wood /Pellets boiler Total system graph 3 tap water Solar collectors Separate Solar Controller Radiator 4 Floor heating P High temperature hot water export tap water 1 2 Indoor unit Flexible pipe 50cm 10 3 6 7 9 Outdoor unit 11 5 8 13 12 14 15 1 High Medium Low 50-80℃ 40-50℃ 25-40℃ Distribution system temperature definitions T T P No Name legend 1 2 3 4 5 6 7 8 9 10 11 12 shutoff valve filter automatic air valve water pump sensor expansion tank pressure gage non-return valve T/P valve for solar system water mixing valve safety valve 14 15 temperaturemeters electric heater socket 1 electric heater socket 2 13 3KW heater T 4 2 10 10 4 2 DRAINAGE

Upload: trandien

Post on 31-Mar-2019

213 views

Category:

Documents


0 download

TRANSCRIPT

wood /Pellets boiler

Total system graph 3

tap water

Solar collectors

Separate Solar Controller

Radiator4

Floor heating

P

High temperature hot water export

tap water

1

2

Indoor unit

Flexible pipe 50cm

10

3

6

79

Outdoor unit

11

5

8

13

12

14

15

1

High

Medium

Low

50-80℃

40-50℃

25-40℃

Distribution systemtemperaturedefinitions

T

T

P

No Name legend

1

2

3

4

5

6

7

8

9

10

11

12

shutoff valve

filter

automatic air valve

water pump

sensor

expansion tank

pressure gage

non-return valve

T/P valve for solar system

water mixing valve

safety valve

14

15

temperaturemeters

electric heater socket 1

electric heater socket 2

13

3KW heater

T

4 2

10

104

2

DRAINAGE

Total system graph 1

tap water

Solar collectors

Separate Solar Controller

Radiator4

Floor heating

P

High temperature hot water export

tap water

1

2

Indoor unit

Flexible pipe 50cm

10

3

6

79

Outdoor unit

11

T

5

8

13

12

14

15

1

2

3

5

7

8

9

High

Medium

Low

50-80℃

40-50℃

25-40℃

Distribution systemtemperaturedefinitions

T

P

No Name legend

1

2

3

4

5

6

7

8

9

10

11

12

shutoff valve

filter

automatic air valve

water pump

sensor

expansion tank

pressure gage

non-return valve

T/P valve for solar system

mixing valve

safety valve

14

15

temperaturemeters

electric heater socket 1

electric heater socket 2

13

3KW heater

T

“LOW/MEDIUM”

16 3-WAY SHUNT

‘ON’

‘ON’

16

16

DRAINAGE

wood /Pellets boiler

Total system graph 2

tap water

Solar collectors

Separate Solar Controller

Radiator4

Floor heating

P

High temperature hot water export

tap water

1

2

Indoor unit

Flexible pipe 50cm

10

3

6

79

Outdoor unit

11

5

8

13

12

14

15

High

Medium

Low

50-80℃

40-50℃

25-40℃

Distribution systemtemperaturedefinitions

T

T

P

No Name legend

1

2

3

4

5

6

7

8

9

10

11

12

shutoff valve

filter

automatic air valve

water pump

sensor

expansion tank

pressure gage

non-return valve

T/P valve for solar system

mixing valve

safety valve

14

15

temperaturemeters

electric heater socket 1

electric heater socket 2

13

3KW heater

T

“LOW/MEDIUM”

3-WAY SHUNT

‘ON’

‘ON’

164

16

16

DRAINAGE

1.1 AIR WATER + MULTIFUNCTIONAL TANK.

DRAINAGE

High temperature hot water export

tap water

1

Indoor unit

Flexible pipe 50cm

13

5

Outdoor unit

8

6

10

9

11

12

No Name legend

1

2

3

4

5

6

7

8

9

10

11

12

shutoff valve

filter

water pump

sensor

expansion tank

non-return valve

Bivalent 4-WAY SHUNT

safety valve

temperaturemeters

electric heater socket 1

electric heater socket 2

T

High

Medium

Low

50-80℃

40-50℃

25-40℃

Distribution systemtemperaturedefinitions

2Radiator

7

3

T

T

4

3KW heater

13 mixing valve

‘ON’

“HIGH”

2.1 AIR WATER + MULTIFUNCTIONAL TANK + SOLAR COLLECTORS.

High temperature hot water export

tap water

1

Indoor unit

Flexible pipe 50cm

6

Outdoor unit

11

8

13

12

14

15

No Name legend

2Radiator

10

4

T

T

16

High

Medium

Low

50-80℃

40-50℃

25-40℃

Distribution systemtemperaturedefinitions

1 shutoff valve

2 filter

3 automatic air valve

4 water pump

5 sensor

6 expansion tank

P7 pressure gage

8 non-return valve

9 T/P valve for solar system

10 BIVALENT H-WAY SHUIUT

11 safety valve

12 3KW heater

temperaturemeters13 T

14 electric heater socket 1 ‘ON’

15 electric heater socket 2

16 MIXING VALVE

DRAINAGE

P

5

4

67

hot water supply

tap water

Radiator

Oil fired boiler

93

Flexible pipe 50cm

Outdoor unit

3.1 AIR WATER +BOILER

P

No Name legend

1

2

3

4

5

6

7

8

9

shutoff valve

filter

water pump

expansion tank

pressure gage

T/P valve for solar system

mixing valve

High

Medium

Low

50-80℃

40-50℃

25-40℃

Distribution systemtemperaturedefinitions

1

23-WAY SHUNT

automatic air valve

8

“HIGH”

10

10 ROOM SENSOR

P

hot water supply

tap water

Radiator

Oil fired boiler

Flexible pipe 50cm

Outdoor unit

3.2、AIR WATER +BOILER

High

Medium

Low

50-80℃

40-50℃

25-40℃

Distribution systemtemperaturedefinitions

P

No Name legend

1

2

3

4

5

6

7

8

9

shutoff valve

filter

water pump

expansion tank

pressure gage

T/P valve for solar system

mixing valve

3-WAY SHUNT

automatic air valve

1

2

5

4

67

93

8

9

11

10

10 ROOM SENSOR

11 ELECTRIC WATERHEATER

“MEDIUM”

Flexible pipe 50cm

Outdoor unit

4.AIR WATER + BOILER + SMALL WATER HEATER IN SERIES WITH THE OIL FIRED BOILER.

High

Medium

Low

50-80℃

40-50℃

25-40℃

Distribution systemtemperaturedefinitions

P

hot water supply

tap water

Radiator

Oil fired boiler

Small water heater

2

1P

No Name legend

1

2

3

4

5

6

7

8

9

shutoff valve

filter

water pump

expansion tank

pressure gage

T/P valve for solar system

mixing valve

3-WAY SHUNT

automatic air valve

5

4

67

3

8

9

“MEDIUM”

4

Radiator

Electric boiler

3 Flexible pipe 50cm

Outdoor unit

5.1 AIR WATER + ELECTRIC BOILER ( HEATING ONLY )

High

Medium

Low

50-80℃

40-50℃

25-40℃

Distribution systemtemperaturedefinitions

2

No Name legend

1

2

3

4

shutoff valve

filter

water pump

3-WAY SHUNT

1

“LOW/MEDIUM”

1

1

6.1 WW+MWT+OIL-‘High’

Drainage

High temperature hot water export

tap water

1

Indoor unit

Flexible pipe 50cm

5

Outdoor unit

8

6

10

9

11

12

No Name legend

1

2

3

4

5

6

7

8

9

10

11

12

shutoff valve

filter

water pump

sensor

expansion tank

non-return valve

Bivalent 4-WAY SHUNT

safety valve

temperaturemeters

electric heater socket 1

electric heater socket 2

3KW heater

High

Medium

Low

50-80℃

40-50℃

25-40℃

Distribution systemtemperaturedefinitions

2

Radiator

7

3

pellets/wood/oil burner

T

T

T

4

10

3

13

13 mixing valve

6.2 WW+BUFFER TANK+OIL-‘High’

Drainage

High temperature hot water export

1

Indoor unit

Flexible pipe 50cm

Outdoor unit

No Name legend

1

2

3

4

5

6

7

8

9

10

shutoff valve

filter

water pump

sensor

expansion tank

Bivalent 4-WAY SHUNT

safety valve

High

Medium

Low

50-80℃

40-50℃

25-40℃

Distribution systemtemperaturedefinitions

2

Radiator

5

4

pellets/wood/oil burner

3

10

mixing valve

75L Water Tank

6

water in

3

8

9

non-return valve

7

ELECTRIC HEATER SOLUET

Flexible pipe 50cm

Outdoor unit

7、AIR WATER + BUFFER TANK.

No Name legend

1

2

3

5

shutoff valve

filter

water pump

mixing valve

High

Medium

Low

50-80℃

40-50℃

25-40℃

Distribution systemtemperaturedefinitions

12

4

5

Radiator

hot water supply

water in 75L Water Tank

Shower coil Ø22 X 15m

Small water heater

DRAINAGE

4

non-return valve

“LOW/MEDIUM”

7

8

6

7

8

9

safety valve kit

expansion tank

6

9

4

SENSOR

ELECTRIC HEATER SOLUET

13