toshiba air conditioning - vrf data sheet · mmd-ap0056sph-e slim ducted features eternal static...

1
MMD-AP0056SPH-E Slim ducted Features n External static pressure can be raised up to 50 Pa n Low noise: low fan speed down to 24 dB(A) n Fresh air intake n Lift pump up to 550 mm lift n Ideal for restricted ceiling voids only 210 mm high n Base or rear return air n This model can only be used with the new e-series VRF outdoor units Toshiba Air Conditioning - VRF Data Sheet www.cdlweb.info Dimensional Drawings All UK duties are based on Cooling Indoor air temperature 22°C DB/16°C WB Outdoor air temperature 28°C DB 50% RH, high fan speed, 5 m pipe run. Heating Indoor air temperature 21°C DB Outdoor air temperature –4°C DB 100% RH, high fan speed, 5 m pipe run. Values are based on the maximum compressor output. Data obtained from Toshiba Air Conditioning Web Data July 2013. Technical Data Model reference MMD-AP0056SPH-E Nominal cooling kW 1.7 Nominal heating kW 1.9 Capacity code 0.6 UK cooling kW 1.5 UK sensible cooling kW 1.3 UK heating kW 1.3 Starting current A 0.51 Running current A 0.29 Suggested fuse size A 5 Power supply V-ph-Hz 220/240-1-50 Interconnecting cable 2-core screened 1.5 mm Sound power H-M-L (base/rear air inlet) dB(A) 42-41-39/50-48-45 Sound pressure H-M-L (base/rear air inlet) dB(A) 35-33-30/27-26-24 Standard air flow H-L m 3 /h 490-400 Standard air flow H-L l/s 137-112 External static pressure (factory default) Pa 6 Static pressure range Pa 10-50 (4 steps) Dimensions (H x W x D) mm 210 x 845 x 645 Unit weight kg 22

Upload: others

Post on 11-Oct-2020

16 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Toshiba Air Conditioning - VRF Data Sheet · MMD-AP0056SPH-E Slim ducted Features Eternal static ressure can be raised u to 50 Pa ow noise low fan seed down to dA Fresh air intae

MMD-AP0056SPH-ESlim ducted

Featuresn External static pressure can be raised up to 50 Pan Low noise: low fan speed down to 24 dB(A)n Fresh air intaken Lift pump up to 550 mm liftn Ideal for restricted ceiling voids only 210 mm highn Base or rear return airn This model can only be used with the new e-series VRF outdoor units

Toshiba Air Conditioning - VRF Data Sheet

www.cdlweb.info

All UK duties are based on Cooling Indoor air temperature 27°C DB/19°C WB Outdoor air temperature 35°C DB 50% RH, high fan speed, 7.5 m pipe run.Heating Indoor air temperature 20°C DB Outdoor air temperature 7°C DB 100% RH, high fan speed, 7.5 m pipe run. Values are based on the maximum compressor output.

Data obtained from Toshiba Air Conditioning September 2015.

Dimensional Drawings

All UK duties are based on Cooling Indoor air temperature 22°C DB/16°C WB Outdoor air temperature 28°C DB 50% RH, high fan speed, 5 m pipe run.Heating Indoor air temperature 21°C DB Outdoor air temperature –4°C DB 100% RH, high fan speed, 5 m pipe run. Values are based on the maximum compressor output.

Data obtained from Toshiba Air Conditioning Web Data July 2013.

Technical DataModel reference MMD-AP0056SPH-ENominal cooling kW 1.7Nominal heating kW 1.9Capacity code 0.6UK cooling kW 1.5UK sensible cooling kW 1.3UK heating kW 1.3Starting current A 0.51Running current A 0.29Suggested fuse size A 5Power supply V-ph-Hz 220/240-1-50Interconnecting cable 2-core screened 1.5 mmSound power H-M-L (base/rear air inlet) dB(A) 42-41-39/50-48-45Sound pressure H-M-L (base/rear air inlet) dB(A) 35-33-30/27-26-24Standard air flow H-L m3/h 490-400Standard air flow H-L l/s 137-112External static pressure (factory default) Pa 6Static pressure range Pa 10-50 (4 steps)Dimensions (H x W x D) mm 210 x 845 x 645Unit weight kg 22