    TECHNICAL REQUIREMENTSS A F E T Y D U R A B I L I T Y E A S E O F M A I N T E N A N C E

    C O S T C O N S T R U C T A B I L I T Y A C C E S S I B I L I T Y S E C U R I T Y

    BUILDING QUALITY DEPT

    Senior Architect Tan Lily

  • 7/27/2019 Topic 1 Technical-Requirements

    2/32

    APRIL 2009 TECHNICAL REQUIREMENT MODULE

    OUTLINEOUTLINE

    1. Key Considerations

    2. Technical requirements3. Regulatory Compliance

    4. References

  • 7/27/2019 Topic 1 Technical-Requirements

    3/32

    APRIL 2009 TECHNICAL REQUIREMENT MODULE

    Key Considerations in Public

    Housing Technical Requirements

    SAFETYSAFETY

    DURABILITYDURABILITY

    EASE OF MAINTENANCEEASE OF MAINTENANCE

    COSTCOST

    ACCESSIBILITYACCESSIBILITY

    CONSTRUCTABILITYCONSTRUCTABILITY

    SECURITYSECURITY

    1

  • 7/27/2019 Topic 1 Technical-Requirements

    4/32

    Technical requirementsA. Safety

    1. Measure against killer litter

    2. Safety barrier at common areas

    3. Safety barrier at roof

    B. Designing for maintainabili ty

    1. Choice of materials

    2. Fabrication method3. Treatment on external facade

    4. Access for maintenance at roof

    5. Gondola Installation

    C. Security1. Unauthorised access

    APRIL 2009 TECHNICAL REQUIREMENT MODULE

    2

  • 7/27/2019 Topic 1 Technical-Requirements

    5/32

    APRIL 2009 TECHNICAL REQUIREMENT MODULE

    SAFETY

    Killer litter

    A girl was killed here by flower pot 5 years ago Recently,within a period of 14 days, there are 2 separate incidents where flower pots

    dropped to the ground floor

    A1

  • 7/27/2019 Topic 1 Technical-Requirements

    6/32

    APRIL 2009 TECHNICAL REQUIREMENT MODULE

    SAFETY

    Killer l itter Potential killerA1

    Bldg features that encourage indiscriminate storing on

    external in the past

  • 7/27/2019 Topic 1 Technical-Requirements

    7/32

    APRIL 2009 TECHNICAL REQUIREMENT MODULE

    SAFETY

    Measures against killer litter Eliminate any

    opportunities for

    storing or hanging ofobjects on external

    facade

    A1

    Ledges are kept to minimumwidth and sloped

    North south orientation eliminate

    the need for sunbreakers

  • 7/27/2019 Topic 1 Technical-Requirements

    8/32

    APRIL 2009 TECHNICAL REQUIREMENT MODULE

    SAFETY

    Measures against killer litter2. Provide safe route for

    residents Provide safe

    route for

    residents

    a. Designate block entrancesand provide protectivecanopies.

    b. Direct residents towards asafe route.

    c. Provide covered walkways.

    d. Locate footpaths andoutdoor communal areasaway from openings.

    A1

  • 7/27/2019 Topic 1 Technical-Requirements

    9/32

    Designate block entrance and provide protective

    canopies

    APRIL 2009 TECHNICAL REQUIREMENT MODULE

    SAFETY

    Measures against litter

    8Designated block entrancewithout overhead protective cover

    Subject

    to killer

    litter risk

    A1

    9Designated block entrance withoverhead protective cover

  • 7/27/2019 Topic 1 Technical-Requirements

    10/32

    APRIL 2009 TECHNICAL REQUIREMENT MODULE

    SAFETY

    Measures against litterA1

    Using landscaping as

    barrier to discourage

    residents form walking

    below openings

    Dispensing withprovision of apron

  • 7/27/2019 Topic 1 Technical-Requirements

    11/32

    SAFETY

    Safety Barrier at common areas Height of safety barrier

    APRIL 2009 TECHNICAL REQUIREMENT MODULE

    1.25m

    A2HDBs requirement

    Height of safety barrier to common

    areas* is 1.25m for added child safety.

    *lift lobbies, common corridors, roofgardens and other areas accessible by

    general public

  • 7/27/2019 Topic 1 Technical-Requirements

    12/32

    APRIL 2009 TECHNICAL REQUIREMENT MODULE

    SAFETY / EASE OF MAINTENANCE

    Safety barrier at main roof Provide 1m high safety barrier

    Along perimeter of main roof ( new)

    Along maintenance route where theres no roof fascia( forexisting)

    Roof safety Railing is recommended Maintenance route

    A3

  • 7/27/2019 Topic 1 Technical-Requirements

    13/32

    APRIL 2009 TECHNICAL REQUIREMENT MODULE

    EASE OF MAINTENANCE/ SAFETY

    Safety barrier at main roof Simple and durable design( extg)

    Height - not lessthan 1000mm

    measured from

    secondary roof level

    Gap -not

    more than

    300mm

    Spacing - not

    more than

    1200mm

    Simple and modular design

    Material

    Galvanised steel

    with anti-rust paint

    system

    A3

    Narrow Access

    Obstruction byservices

  • 7/27/2019 Topic 1 Technical-Requirements

    14/32

    APRIL 2009 TECHNICAL REQUIREMENT MODULE

    Designing for Maintainability Considerations

    Durable

    In material and construction

    long life expectancy

    able to withstand rough usage

    Ease of construction Ease of maintenance

    Minimum maintenance

    Easy to inspect and maintain

    Access for maintenance

    Low operating, repair, replacement & maintenance

    cost

    Easily available

    B1

  • 7/27/2019 Topic 1 Technical-Requirements

    15/32

    APRIL 2009 TECHNICAL REQUIREMENT MODULE

    DURABILITY

    Choice of material Glass shall not be used as roofing material or safety

    barrierB1

  • 7/27/2019 Topic 1 Technical-Requirements

    16/32

    APRIL 2009 TECHNICAL REQUIREMENT MODULE

    DURABILITY

    Fabrication of components

    27

    Use precast elements and factory prefabrication. Rely

    less on workmanship on site

    B2

  • 7/27/2019 Topic 1 Technical-Requirements

    17/32

    APRIL 2009 TECHNICAL REQUIREMENT MODULE`

    DURABILITY

    Fabrication of components Rely less on workmanship on site

    Misaligned hole

    Missing bolts

    Bolts not tightened

    Panel loosened

    Missing base plate

    B2

  • 7/27/2019 Topic 1 Technical-Requirements

    18/32

    APRIL 2009 TECHNICAL REQUIREMENT MODULE

    DURABILITY

    Fabrication of components Corner windows

    9Use corner mull ion for amore robust joint.

    8Avoid use of sealant jointfor corner windows. Sealant

    deteriorates over time and is

    likely to cause maintenance

    problem and create undue

    inconveniences to lessees.

    B2

  • 7/27/2019 Topic 1 Technical-Requirements

    19/32

    SAFETY / EASE OF MAINTENANCE/ COST/

    External facade Avoid

    External plastering

    Brick-cladding

    In-situ tiling to faade walls

    Other form of cladding or

    attachments at heights

    Safety risk due to fallingpanel

    Costly repair

    Difficult to inspect and

    maintain

    APRIL 2009 TECHNICAL REQUIREMENT MODULE

    B3

    Cladding panel dislodged

    Brick cladding dislodged

  • 7/27/2019 Topic 1 Technical-Requirements

    20/32

    SAFETY / EASE OF MAINTENANCE/ COST

    Roof Metal or clay roof shall NOT be used above 2nd storey of any

    HDB residential buildings.

    APRIL 2009 TECHNICAL REQUIREMENT MODULE

    B3

    Blown away roof

    Part of roof panel dislodged

  • 7/27/2019 Topic 1 Technical-Requirements

    21/32

    APRIL 2009 TECHNICAL REQUIREMENT MODULE

    Provide at least

    ONE staircase

    access to the

    main roof.

    EASE OF MAINTENANCE

    Access for maintenance - roof

    POINTS TO NOTE:Provision of access for maintenance purpose

    a. at least one staircase access to the main roof

    b. staircase access from main roof to the lift machine room

    B4

  • 7/27/2019 Topic 1 Technical-Requirements

    22/32

    APRIL 2009 TECHNICAL REQUIREMENT MODULE

    Primary roof

    POINTS TO NOTE:

    1. Provide min 1.8mheadroom below

    water tank for

    maintenance of

    pipes.

    2. Provide access

    platform to water

    tanks.3. Provide roof over

    booster pump room.

    EASE OF MAINTENANCE/ SAFETY

    Access for maintenance - roof3

    min1.8m

    12

    B4

  • 7/27/2019 Topic 1 Technical-Requirements

    23/32

    APRIL 2009 TECHNICAL REQUIREMENT MODULE

    EASE OF MAINTENANCE/ SAFETY

    Access for maintenance - roof1

    23

    Access platform to water

    tank

    B4

  • 7/27/2019 Topic 1 Technical-Requirements

    24/32

    EASE OF MAINTENANCE

    Installation of gondola Ensure all roofs, water tanks,

    features and every part of

    external faade is accessible formaintenance.

    Gondola is the MAIN means of

    access for maintenance of

    external faade.

    Design for installation of

    gondola

    Ensure no obstructions

    Adequate space

    B5

  • 7/27/2019 Topic 1 Technical-Requirements

    25/32

    APRIL 2009 TECHNICAL REQUIREMENT MODULE

    EASE OF MAINTENANCE

    Installation of gondola Obstruction to installation of gondolaB5

    Metal roof projects 3 m from building

    edge, not accessible from roof or by

    gondola for maintenance and repair

    Cantilevered roof obstructs

    the hanging of maintenance

    gondola

  • 7/27/2019 Topic 1 Technical-Requirements

    26/32

    APRIL 2009 TECHNICAL REQUIREMENT MODULE

    SECURITY

    Linkway connection

    Roof of covered walkway provided possible unauthorised access to residential unit.

    Although window are at high level, resident felt insecure. Grilles had to be installed at

    MSCP opening.

    Opening at MSCP

    Ensure linkway do not connect below opening of

    residential unitsC1

  • 7/27/2019 Topic 1 Technical-Requirements

    27/32

    APRIL 2009 TECHNICAL REQUIREMENT MODULE

    SECURITY

    External ledge Take care possible unauthorised access from lift lobby

    Provide grille with lock at lift lobby

    to prevent unauthorised access to

    CRC roof ( maintenance access is

    still required).

    C1

  • 7/27/2019 Topic 1 Technical-Requirements

    28/32

    APRIL 2009 TECHNICAL REQUIREMENT MODULE

    SECURITY

    Features Ensure external features does not facilitate

    unauthorised access to units aboveC1

  • 7/27/2019 Topic 1 Technical-Requirements

    29/32

    APRIL 2009 TECHNICAL REQUIREMENT MODULE

    Regulatory Compliance

    Submission to authorities as as per private projects.

    Need to submit to HDB thru CORENET.

    Resolve regulatory compliance issues early prior tolaunch or exhibition

    Avoid mechanical system as means of compliance MSCP should be designed without need for sprinkler or mechanical

    ventilation system

    All escape staircases & lobbies should be naturally ventilated

    Optimum compliance

    3

  • 7/27/2019 Topic 1 Technical-Requirements

    30/32

    APRIL 2009 TECHNICAL REQUIREMENT MODULE

    References

    1. HDB standard specifications

    2. HDB Guide Drawings

    3. Town Councils publication -

    Design for Maintainability

    4

  • 7/27/2019 Topic 1 Technical-Requirements

    31/32

    THANK YOU

  • 7/27/2019 Topic 1 Technical-Requirements

    32/32

    APRIL 2009 TECHNICAL REQUIREMENT MODULE

    SAFETY

    Measures against litterA1