topic 1 technical-requirements
TRANSCRIPT
-
7/27/2019 Topic 1 Technical-Requirements
1/32
TECHNICAL REQUIREMENTSS A F E T Y D U R A B I L I T Y E A S E O F M A I N T E N A N C E
C O S T C O N S T R U C T A B I L I T Y A C C E S S I B I L I T Y S E C U R I T Y
BUILDING QUALITY DEPT
Senior Architect Tan Lily
-
7/27/2019 Topic 1 Technical-Requirements
2/32
APRIL 2009 TECHNICAL REQUIREMENT MODULE
OUTLINEOUTLINE
1. Key Considerations
2. Technical requirements3. Regulatory Compliance
4. References
-
7/27/2019 Topic 1 Technical-Requirements
3/32
APRIL 2009 TECHNICAL REQUIREMENT MODULE
Key Considerations in Public
Housing Technical Requirements
SAFETYSAFETY
DURABILITYDURABILITY
EASE OF MAINTENANCEEASE OF MAINTENANCE
COSTCOST
ACCESSIBILITYACCESSIBILITY
CONSTRUCTABILITYCONSTRUCTABILITY
SECURITYSECURITY
1
-
7/27/2019 Topic 1 Technical-Requirements
4/32
Technical requirementsA. Safety
1. Measure against killer litter
2. Safety barrier at common areas
3. Safety barrier at roof
B. Designing for maintainabili ty
1. Choice of materials
2. Fabrication method3. Treatment on external facade
4. Access for maintenance at roof
5. Gondola Installation
C. Security1. Unauthorised access
APRIL 2009 TECHNICAL REQUIREMENT MODULE
2
-
7/27/2019 Topic 1 Technical-Requirements
5/32
APRIL 2009 TECHNICAL REQUIREMENT MODULE
SAFETY
Killer litter
A girl was killed here by flower pot 5 years ago Recently,within a period of 14 days, there are 2 separate incidents where flower pots
dropped to the ground floor
A1
-
7/27/2019 Topic 1 Technical-Requirements
6/32
APRIL 2009 TECHNICAL REQUIREMENT MODULE
SAFETY
Killer l itter Potential killerA1
Bldg features that encourage indiscriminate storing on
external in the past
-
7/27/2019 Topic 1 Technical-Requirements
7/32
APRIL 2009 TECHNICAL REQUIREMENT MODULE
SAFETY
Measures against killer litter Eliminate any
opportunities for
storing or hanging ofobjects on external
facade
A1
Ledges are kept to minimumwidth and sloped
North south orientation eliminate
the need for sunbreakers
-
7/27/2019 Topic 1 Technical-Requirements
8/32
APRIL 2009 TECHNICAL REQUIREMENT MODULE
SAFETY
Measures against killer litter2. Provide safe route for
residents Provide safe
route for
residents
a. Designate block entrancesand provide protectivecanopies.
b. Direct residents towards asafe route.
c. Provide covered walkways.
d. Locate footpaths andoutdoor communal areasaway from openings.
A1
-
7/27/2019 Topic 1 Technical-Requirements
9/32
Designate block entrance and provide protective
canopies
APRIL 2009 TECHNICAL REQUIREMENT MODULE
SAFETY
Measures against litter
8Designated block entrancewithout overhead protective cover
Subject
to killer
litter risk
A1
9Designated block entrance withoverhead protective cover
-
7/27/2019 Topic 1 Technical-Requirements
10/32
APRIL 2009 TECHNICAL REQUIREMENT MODULE
SAFETY
Measures against litterA1
Using landscaping as
barrier to discourage
residents form walking
below openings
Dispensing withprovision of apron
-
7/27/2019 Topic 1 Technical-Requirements
11/32
SAFETY
Safety Barrier at common areas Height of safety barrier
APRIL 2009 TECHNICAL REQUIREMENT MODULE
1.25m
A2HDBs requirement
Height of safety barrier to common
areas* is 1.25m for added child safety.
*lift lobbies, common corridors, roofgardens and other areas accessible by
general public
-
7/27/2019 Topic 1 Technical-Requirements
12/32
APRIL 2009 TECHNICAL REQUIREMENT MODULE
SAFETY / EASE OF MAINTENANCE
Safety barrier at main roof Provide 1m high safety barrier
Along perimeter of main roof ( new)
Along maintenance route where theres no roof fascia( forexisting)
Roof safety Railing is recommended Maintenance route
A3
-
7/27/2019 Topic 1 Technical-Requirements
13/32
APRIL 2009 TECHNICAL REQUIREMENT MODULE
EASE OF MAINTENANCE/ SAFETY
Safety barrier at main roof Simple and durable design( extg)
Height - not lessthan 1000mm
measured from
secondary roof level
Gap -not
more than
300mm
Spacing - not
more than
1200mm
Simple and modular design
Material
Galvanised steel
with anti-rust paint
system
A3
Narrow Access
Obstruction byservices
-
7/27/2019 Topic 1 Technical-Requirements
14/32
APRIL 2009 TECHNICAL REQUIREMENT MODULE
Designing for Maintainability Considerations
Durable
In material and construction
long life expectancy
able to withstand rough usage
Ease of construction Ease of maintenance
Minimum maintenance
Easy to inspect and maintain
Access for maintenance
Low operating, repair, replacement & maintenance
cost
Easily available
B1
-
7/27/2019 Topic 1 Technical-Requirements
15/32
APRIL 2009 TECHNICAL REQUIREMENT MODULE
DURABILITY
Choice of material Glass shall not be used as roofing material or safety
barrierB1
-
7/27/2019 Topic 1 Technical-Requirements
16/32
APRIL 2009 TECHNICAL REQUIREMENT MODULE
DURABILITY
Fabrication of components
27
Use precast elements and factory prefabrication. Rely
less on workmanship on site
B2
-
7/27/2019 Topic 1 Technical-Requirements
17/32
APRIL 2009 TECHNICAL REQUIREMENT MODULE`
DURABILITY
Fabrication of components Rely less on workmanship on site
Misaligned hole
Missing bolts
Bolts not tightened
Panel loosened
Missing base plate
B2
-
7/27/2019 Topic 1 Technical-Requirements
18/32
APRIL 2009 TECHNICAL REQUIREMENT MODULE
DURABILITY
Fabrication of components Corner windows
9Use corner mull ion for amore robust joint.
8Avoid use of sealant jointfor corner windows. Sealant
deteriorates over time and is
likely to cause maintenance
problem and create undue
inconveniences to lessees.
B2
-
7/27/2019 Topic 1 Technical-Requirements
19/32
SAFETY / EASE OF MAINTENANCE/ COST/
External facade Avoid
External plastering
Brick-cladding
In-situ tiling to faade walls
Other form of cladding or
attachments at heights
Safety risk due to fallingpanel
Costly repair
Difficult to inspect and
maintain
APRIL 2009 TECHNICAL REQUIREMENT MODULE
B3
Cladding panel dislodged
Brick cladding dislodged
-
7/27/2019 Topic 1 Technical-Requirements
20/32
SAFETY / EASE OF MAINTENANCE/ COST
Roof Metal or clay roof shall NOT be used above 2nd storey of any
HDB residential buildings.
APRIL 2009 TECHNICAL REQUIREMENT MODULE
B3
Blown away roof
Part of roof panel dislodged
-
7/27/2019 Topic 1 Technical-Requirements
21/32
APRIL 2009 TECHNICAL REQUIREMENT MODULE
Provide at least
ONE staircase
access to the
main roof.
EASE OF MAINTENANCE
Access for maintenance - roof
POINTS TO NOTE:Provision of access for maintenance purpose
a. at least one staircase access to the main roof
b. staircase access from main roof to the lift machine room
B4
-
7/27/2019 Topic 1 Technical-Requirements
22/32
APRIL 2009 TECHNICAL REQUIREMENT MODULE
Primary roof
POINTS TO NOTE:
1. Provide min 1.8mheadroom below
water tank for
maintenance of
pipes.
2. Provide access
platform to water
tanks.3. Provide roof over
booster pump room.
EASE OF MAINTENANCE/ SAFETY
Access for maintenance - roof3
min1.8m
12
B4
-
7/27/2019 Topic 1 Technical-Requirements
23/32
APRIL 2009 TECHNICAL REQUIREMENT MODULE
EASE OF MAINTENANCE/ SAFETY
Access for maintenance - roof1
23
Access platform to water
tank
B4
-
7/27/2019 Topic 1 Technical-Requirements
24/32
EASE OF MAINTENANCE
Installation of gondola Ensure all roofs, water tanks,
features and every part of
external faade is accessible formaintenance.
Gondola is the MAIN means of
access for maintenance of
external faade.
Design for installation of
gondola
Ensure no obstructions
Adequate space
B5
-
7/27/2019 Topic 1 Technical-Requirements
25/32
APRIL 2009 TECHNICAL REQUIREMENT MODULE
EASE OF MAINTENANCE
Installation of gondola Obstruction to installation of gondolaB5
Metal roof projects 3 m from building
edge, not accessible from roof or by
gondola for maintenance and repair
Cantilevered roof obstructs
the hanging of maintenance
gondola
-
7/27/2019 Topic 1 Technical-Requirements
26/32
APRIL 2009 TECHNICAL REQUIREMENT MODULE
SECURITY
Linkway connection
Roof of covered walkway provided possible unauthorised access to residential unit.
Although window are at high level, resident felt insecure. Grilles had to be installed at
MSCP opening.
Opening at MSCP
Ensure linkway do not connect below opening of
residential unitsC1
-
7/27/2019 Topic 1 Technical-Requirements
27/32
APRIL 2009 TECHNICAL REQUIREMENT MODULE
SECURITY
External ledge Take care possible unauthorised access from lift lobby
Provide grille with lock at lift lobby
to prevent unauthorised access to
CRC roof ( maintenance access is
still required).
C1
-
7/27/2019 Topic 1 Technical-Requirements
28/32
APRIL 2009 TECHNICAL REQUIREMENT MODULE
SECURITY
Features Ensure external features does not facilitate
unauthorised access to units aboveC1
-
7/27/2019 Topic 1 Technical-Requirements
29/32
APRIL 2009 TECHNICAL REQUIREMENT MODULE
Regulatory Compliance
Submission to authorities as as per private projects.
Need to submit to HDB thru CORENET.
Resolve regulatory compliance issues early prior tolaunch or exhibition
Avoid mechanical system as means of compliance MSCP should be designed without need for sprinkler or mechanical
ventilation system
All escape staircases & lobbies should be naturally ventilated
Optimum compliance
3
-
7/27/2019 Topic 1 Technical-Requirements
30/32
APRIL 2009 TECHNICAL REQUIREMENT MODULE
References
1. HDB standard specifications
2. HDB Guide Drawings
3. Town Councils publication -
Design for Maintainability
4
-
7/27/2019 Topic 1 Technical-Requirements
31/32
THANK YOU
-
7/27/2019 Topic 1 Technical-Requirements
32/32
APRIL 2009 TECHNICAL REQUIREMENT MODULE
SAFETY
Measures against litterA1