top ten emc problems with emc troubleshooting ver 1 · pdf file3 emc engineering series page 5...

33
1 Top Ten EMC Problems & EMC Troubleshooting Techniques by Kenneth Wyatt, DVD, Colorado Springs Rev. 1, Feb 26, 2007 EMC Engineering EMC Engineering Series Page 2 1a. Ground Impedance The overwhelming majority of high-frequency problems, whether related to emissions, immunity or self-compatibility have high ground return impedance as a root cause. Wires and traces have a high impedance. This is why a ground return plane should be used at high frequencies High-frequency effects start occurring at 1 MHz The inductance of a wire in free space is about 20 nH/inch A one-inch wire (or trace) has an impedance of at 100 MHz 2πfl 12

Upload: buikhuong

Post on 13-Mar-2018

228 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: Top Ten EMC Problems with EMC Troubleshooting Ver 1 · PDF file3 EMC Engineering Series Page 5 2a. Poor Cable Grounding RF Immunity problems almost always involves a cable ¾Shield

1

Top Ten EMC Problems & EMC Troubleshooting Techniquesby Kenneth Wyatt, DVD, Colorado SpringsRev. 1, Feb 26, 2007

EMC Engineering

EMC Engineering Series Page 2

1a. Ground Impedance

The overwhelming majority of high-frequency problems, whetherrelated to emissions, immunity or self-compatibility have highground return impedance as a root cause.

Wires and traces have a high impedance. This is why a groundreturn plane should be used at high frequencies

High-frequency effects start occurring at 1 MHz

The inductance of a wire in free space is about 20 nH/inch

A one-inch wire (or trace) has an impedance ofat 100 MHz

2πfl ≈12Ω

Page 2: Top Ten EMC Problems with EMC Troubleshooting Ver 1 · PDF file3 EMC Engineering Series Page 5 2a. Poor Cable Grounding RF Immunity problems almost always involves a cable ¾Shield

2

EMC Engineering Series Page 3

1b. Slot caught during a design review

EMC Engineering Series Page 4

Attempt at shielding module failed to connect halves!

1c. Poor shield integrity

Module halves copper-plated

Page 3: Top Ten EMC Problems with EMC Troubleshooting Ver 1 · PDF file3 EMC Engineering Series Page 5 2a. Poor Cable Grounding RF Immunity problems almost always involves a cable ¾Shield

3

EMC Engineering Series Page 5

2a. Poor Cable Grounding

RF Immunity problems almost always involves a cable

Shield “pigtails” are bad – circumferential (360 degrees) are best

EMC Engineering Series Page 6

2b. Poor Cable Grounding (continued)Divert the current back to the shielded enclosure• Proper termination of the cable shield back to the enclosure is the key

Block the current with a high-impedance ferrite choke

PC boardI/O Cable

Enclosure

Icm --->

Page 4: Top Ten EMC Problems with EMC Troubleshooting Ver 1 · PDF file3 EMC Engineering Series Page 5 2a. Poor Cable Grounding RF Immunity problems almost always involves a cable ¾Shield

4

EMC Engineering Series Page 7

2c. Connector penetration through shield

Module was unshielded, main connector ground shells hadno connection with mate, connectors penetrated enclosure

EMC Engineering Series Page 8

2d. Connector penetration through shield (cont.)

Module halves copper-plated, finger stock added to connectorsand ribbed main connector ground shell connects with mate

Page 5: Top Ten EMC Problems with EMC Troubleshooting Ver 1 · PDF file3 EMC Engineering Series Page 5 2a. Poor Cable Grounding RF Immunity problems almost always involves a cable ¾Shield

5

EMC Engineering Series Page 9

2e. Good Cable GroundingIdeal I/O connector:

Notice the designincorporates an integratedgrounding connection,which solidly connectsshielded enclosure withconnector ground shellin multiple locations.

The connector groundshell then connects to thecable shield.

Good cable grounding design – cable shield properly connectedto metal enclosure.

EMC Engineering Series Page 10

2f. Improved Cable/Connector Grounding

Shim with fingers added to shunt internal noise currents

!!

Page 6: Top Ten EMC Problems with EMC Troubleshooting Ver 1 · PDF file3 EMC Engineering Series Page 5 2a. Poor Cable Grounding RF Immunity problems almost always involves a cable ¾Shield

6

EMC Engineering Series Page 11

3. Emissions From Switching Devices

Switched high-voltages couple to heat sinks and radiate

Use bypassing and ground the heatsink (multiple points)

EMC Engineering Series Page 12

4a. LCD Emissions

Display cable radiates and excites the metal LCD housing

Ground the LCD housing to the enclosure in multiple points

Page 7: Top Ten EMC Problems with EMC Troubleshooting Ver 1 · PDF file3 EMC Engineering Series Page 5 2a. Poor Cable Grounding RF Immunity problems almost always involves a cable ¾Shield

7

EMC Engineering Series Page 13

4b. LCD Emissions

Display cable radiates and excites the metal LCD housing

Ground the LCD housing to the enclosure in multiple points

EMC Engineering Series Page 14

5a. Stray Internal Coupling Paths

Adding an external ferrite choke on the I/O cable often works best

Interrupt the coupling path with a Faraday shield

Page 8: Top Ten EMC Problems with EMC Troubleshooting Ver 1 · PDF file3 EMC Engineering Series Page 5 2a. Poor Cable Grounding RF Immunity problems almost always involves a cable ¾Shield

8

EMC Engineering Series Page 15

5b. Data lines running underneath xtal oscillator

Data lines couple 100 MHz (and harmonics) through I/O connector to secondPC board; which in that area, is referenced to the power plane (with gaps).

EMC Engineering Series Page 16

7a. Crosstalk

Most often due to a self-compatibility problem that occurs whennoisy source currents come into close proximity to sensitiveanalog, or low-level digital, signals

Route power and signals in separate cables

Use shielded cables

For circuit trace couplings, use additional separationor grounded “guard” traces in between the source andreceptor traces

Page 9: Top Ten EMC Problems with EMC Troubleshooting Ver 1 · PDF file3 EMC Engineering Series Page 5 2a. Poor Cable Grounding RF Immunity problems almost always involves a cable ¾Shield

9

EMC Engineering Series Page 17

7b. Crosstalk in Solid Ground PlanesCrosstalk between two conductors depends on their mutual inductanceand capacitance. Usually, the inductive crosstalk is dominant.

EMC Engineering Series Page 18

7c. Reducing Crosstalk With A Guard Trace

Ref: Signal Integrity – Simplified, Bogatin

Noise

130 mV

39 mV

22 mV

Page 10: Top Ten EMC Problems with EMC Troubleshooting Ver 1 · PDF file3 EMC Engineering Series Page 5 2a. Poor Cable Grounding RF Immunity problems almost always involves a cable ¾Shield

10

EMC Engineering Series Page 19

7d. Use the “3W” Rule During Layout

Clocks and periodic signals havethe greatest chance of causingcrosstalk in other traces.

Minimize crosstalk effects byusing the “3W” rule; that is,ensure that all critical tracesare “buffered” by at least 3“trace-widths surroundingeach potential source andvictim trace.

Increasing the spacing from 1Wto 3W will decrease far-endcrosstalk by 65%.

EMC Engineering Series Page 20

7e. Differential Pairs and the “3W” Rule

I usually consider 3-5W the minimum spacing for any critical traceto board edge spacing.

Page 11: Top Ten EMC Problems with EMC Troubleshooting Ver 1 · PDF file3 EMC Engineering Series Page 5 2a. Poor Cable Grounding RF Immunity problems almost always involves a cable ¾Shield

11

EMC Engineering Series Page 21

8a. Inadequate Signal Returns

A common situation with cables, as well as pin out designs inASICs or other LSI devices is lack of adequate signal returnwires (or pins)

Unless the return path impedance is zero, a fraction of the currentwill likely return on a stray path, creating large loop currents

Route power and signals in separate cables

Use shielded cables

Add more ground return pins to ASIC/FPGA definitions(50/50% is ideal)

EMC Engineering Series Page 22

8b. Inadequate Signal Returns

Ensure adequate number andposition of signal return pins.

Page 12: Top Ten EMC Problems with EMC Troubleshooting Ver 1 · PDF file3 EMC Engineering Series Page 5 2a. Poor Cable Grounding RF Immunity problems almost always involves a cable ¾Shield

12

EMC Engineering Series Page 23

9a. Discontinuous Return Paths

Most PC board problems can be traced to discontinuous signalreturn paths. This is becoming more of an issue with increasingclock frequencies used today.

Ideally, the signal travels out a trace and returns immediatelyunder that trace

All to often, the return path is broken by a discontinuity, such asa gap or slot in the ground plane or the signal trace passes througha via and changes reference planes

Examine ground (and power) plane layers for gaps and slots

Add extra vias for return currents when switching reference planes

EMC Engineering Series Page 24

9b. Generation of differential-mode emission

Montrose, EMC and the Printed Circuit Board, IEEE Press, 1999

YES!

NO!

DM current flows in a loop.The loop radiates energy.

Page 13: Top Ten EMC Problems with EMC Troubleshooting Ver 1 · PDF file3 EMC Engineering Series Page 5 2a. Poor Cable Grounding RF Immunity problems almost always involves a cable ¾Shield

13

EMC Engineering Series Page 25

9c. Discontinuous Return Paths (examples)

!!

EMC Engineering Series Page 26

9d. Slots in acquisition board signal return plane

Temporary bridge with copper tape reduced emissions 17 dB!

Noisy IC straddlinggap in ground plane

Large gap in ground plane

Many more gaps

Page 14: Top Ten EMC Problems with EMC Troubleshooting Ver 1 · PDF file3 EMC Engineering Series Page 5 2a. Poor Cable Grounding RF Immunity problems almost always involves a cable ¾Shield

14

EMC Engineering Series Page 27

9e. Discontinuous Return Paths (examples)

EMC Engineering Series Page 28

9f. Discontinuous Return Paths (examples)

Page 15: Top Ten EMC Problems with EMC Troubleshooting Ver 1 · PDF file3 EMC Engineering Series Page 5 2a. Poor Cable Grounding RF Immunity problems almost always involves a cable ¾Shield

15

EMC Engineering Series Page 29

9g. Trace passing through two planes with via

Ref: Ott, EMC Aspects of Future High Speed Digital Designs, PCB-01049

Question: where does the return signal current flow?

Source

Termination

EMC Engineering Series Page 30

10a. ESD In Metal Enclosures

Page 16: Top Ten EMC Problems with EMC Troubleshooting Ver 1 · PDF file3 EMC Engineering Series Page 5 2a. Poor Cable Grounding RF Immunity problems almost always involves a cable ¾Shield

16

EMC Engineering Series Page 31

10b. Failure Modes Caused by ESD

Typical failure modes include a change of instrument state(front panel control), CPU reset, instrument lockup, loss of data

Fix by shielding, rerouting cables, separation of receptor circuits

EMC Pre-Compliance Testing & Troubleshootingby Kenneth Wyatt, DVD, Colorado SpringsRev 1, Feb 26, 2007

Electromagnetic Compatibility Engineering

Page 17: Top Ten EMC Problems with EMC Troubleshooting Ver 1 · PDF file3 EMC Engineering Series Page 5 2a. Poor Cable Grounding RF Immunity problems almost always involves a cable ¾Shield

17

EMC Engineering Series Page 33

Five Key Threats

These comprise 95% of all EMC problems(EDN Magazine)

1. Radiated Emissions2. ESD (susceptibility)3. RF Fields (susceptibility)4. Power disturbances5. Internal compatibility (crosstalk, etc.)

The solution to most EMC problems is toCONTROL THE PATH OF CURRENT.

EMC Engineering Series Page 34

“Source-Path-Receptor” Model

Source Energy Transfer Receptor(emitter) (coupling path) (receiver)

Seam, Slot,Cable TV, Radio

Oscillator

Seam, Slot,Cable

ElectronicCircuitry

RadiatedEmission

RadiatedImmunity

ESD

Page 18: Top Ten EMC Problems with EMC Troubleshooting Ver 1 · PDF file3 EMC Engineering Series Page 5 2a. Poor Cable Grounding RF Immunity problems almost always involves a cable ¾Shield

18

EMC Engineering Series Page 35

EMC Troubleshooting Kit

Pelican 1514 roller caseExtra cables, adapters, etc.Tool kitDMMTin can antennaLine filterHarmonic comb generatorFerritesWrist strap

ESD meterPower adaptersSpectrum AnalyzerSniffer probe set“Bow-tie” antennaESD generatorCurrent probeBroadband preamp

EMC Engineering Series Page 36

Major Contents

Current ProbeSpectrum Analyzer

E- and H-Field probes

Wideband Preamp Conductivity ProbeSmall Transmitter

Page 19: Top Ten EMC Problems with EMC Troubleshooting Ver 1 · PDF file3 EMC Engineering Series Page 5 2a. Poor Cable Grounding RF Immunity problems almost always involves a cable ¾Shield

19

EMC Engineering Series Page 37

EMC Troubleshooting Kit

What can you do with it?

The EMC troubleshooting kit may be used for the following:

1. Identifying radiated emission sources on PC boards

2. Discovering leaky seams in enclosures

3. Measuring cable common-mode currents / radiation

4. Making quick “A-B” comparisons for proposed design changes

5. Testing for radiated and ESD immunity

6. Highly portable – may be used as a mini “EMC crash cart”

EMC Engineering Series Page 38

Simple Pre-Compliance Tests & Troubleshooting

•Shielding tests•Analyze/measure crystal oscillator harmonics•E- and H-field probing

• PC Boards (E- and H-field probes)• Cables (current probes)• Shields (surface current and 4-point probes)

•Measure bare PC board emissions•Measure conducted emissions in cables

Page 20: Top Ten EMC Problems with EMC Troubleshooting Ver 1 · PDF file3 EMC Engineering Series Page 5 2a. Poor Cable Grounding RF Immunity problems almost always involves a cable ¾Shield

20

EMC Engineering Series Page 39

“Mini” Harmonic Comb Generator Used For Shielding Effectiveness Test

Wyatt/Chaney, RFI Measurements Using a Harmonic Comb Generator, RF Design Magazine, Jan. 1991

Can be placed inside aproduct. Used for shieldingeffectiveness measurements.

Step recovery diode circuit produces5 MHz harmonics from 30 to 1500 MHz

EMC Engineering Series Page 40

Comb Generator Taped To Prototype Product

Page 21: Top Ten EMC Problems with EMC Troubleshooting Ver 1 · PDF file3 EMC Engineering Series Page 5 2a. Poor Cable Grounding RF Immunity problems almost always involves a cable ¾Shield

21

EMC Engineering Series Page 41

Then Comb Generator Is Measured Alone

EMC Engineering Series Page 42

Shielding Effectiveness Plot Is The Difference!Shielding Effectiveness - MSO6000-Series Prototype

0

5

10

15

20

25

30

35

40

45

0

100

200

300

400

500

600

700

800

900

1000

Frequency (MHz)

SE (d

B)

CablesNo Cables

Ignore this area -running out ofdynamic range.

Need to watch this freq!

Page 22: Top Ten EMC Problems with EMC Troubleshooting Ver 1 · PDF file3 EMC Engineering Series Page 5 2a. Poor Cable Grounding RF Immunity problems almost always involves a cable ¾Shield

22

EMC Engineering Series Page 43

Typical EMI Diagnostic Setup

Wilcox, A Design Process for Achieving Electromagnetic Compatibility, Compliance Engineering

EMC Engineering Series Page 44

Examples Of Home Made Loop (H-Field) Probes

Page 23: Top Ten EMC Problems with EMC Troubleshooting Ver 1 · PDF file3 EMC Engineering Series Page 5 2a. Poor Cable Grounding RF Immunity problems almost always involves a cable ¾Shield

23

EMC Engineering Series Page 45

Constructing a simple loop probe

Roleson, Finding EMI Resonances in Structures, EMC Test & Design, Jan/Feb 1992

EMC Engineering Series Page 46

“Mini” loop probe

Bend the center conductor of a thin coaxcable into a small loop and solder it to thebraid. Than cover with silicon sealer.

Page 24: Top Ten EMC Problems with EMC Troubleshooting Ver 1 · PDF file3 EMC Engineering Series Page 5 2a. Poor Cable Grounding RF Immunity problems almost always involves a cable ¾Shield

24

EMC Engineering Series Page 47

Commercial Loop Probes

Commercial probes areavailable from severalsources:Beehive Electronicsprobes pictured…www.beehiveelectronics.com

EMC Engineering Series Page 48

Mapping Of PC Board “Hot Spots”½” Magnetic field probe for coursemeasurements

“Micro” magnetic field probe for finemeasurements

Page 25: Top Ten EMC Problems with EMC Troubleshooting Ver 1 · PDF file3 EMC Engineering Series Page 5 2a. Poor Cable Grounding RF Immunity problems almost always involves a cable ¾Shield

25

EMC Engineering Series Page 49

Using A Current Probe To Measure Cable Common-Mode Currents

EMC Engineering Series Page 50

Current Probe Transfer ImpedanceRather than carrying out aprecise calculation, it issufficient to measure thevoltage with a known currentand frequency passing throughthe probe.

This measurement is usuallyexpressed as “transferimpedance” (ZT).

Or, expressed in dB:

Page 26: Top Ten EMC Problems with EMC Troubleshooting Ver 1 · PDF file3 EMC Engineering Series Page 5 2a. Poor Cable Grounding RF Immunity problems almost always involves a cable ¾Shield

26

EMC Engineering Series Page 51

Application Of The Current Probe - ExampleFor example, consider the problem of determining the level of probevoltage that will correspond to a CM current on a cable that wouldjust meet the radiated emission regulatory limit.

Clamping the probe around a cable and lumping the net CM currentinto one wire of length L gives the net radiated emission a distance daway. Note we must divide Eq. 8.16 by 2, since that result was fortwo wires carrying a current of IC. Assuming FCC-B limit at 30 MHz(100 uV/m) and 1m cable.

From: Introduction to Electromagnetic Compatibility, Paul

EMC Engineering Series Page 52

Ferrite Chokes Block Common-Mode Currents

Often used on keyboard, mouse or video cablesVery useful for troubleshootingManufactures often provide free evaluation kitsBest used on low-Z cables

Page 27: Top Ten EMC Problems with EMC Troubleshooting Ver 1 · PDF file3 EMC Engineering Series Page 5 2a. Poor Cable Grounding RF Immunity problems almost always involves a cable ¾Shield

27

EMC Engineering Series Page 53

Line Cord EmissionsIf the line cord is suspected of emitting HF harmonics, insert an external line filter in seriesIf the emission level (or measured common-mode current) drops, then you need to design in better line filteringAn external filter may be made with an extra power line filter module and spare line cordCut the cord down to minimal size and carefully solder the stripped ends to the filter, observing the correct connections. Wrap with electrical tape.

EMC Engineering Series Page 54

Testing A Bare PC Board For Radiated Emissions

Page 28: Top Ten EMC Problems with EMC Troubleshooting Ver 1 · PDF file3 EMC Engineering Series Page 5 2a. Poor Cable Grounding RF Immunity problems almost always involves a cable ¾Shield

28

EMC Engineering Series Page 55

Multiple Crystal Oscillator Analysis

Avoid selecting fundamental oscillator frequencies whose harmonics end upcloser to each other than 120 kHz (CISPR 16 quasi-peak measurement bandwidth)

EMC Engineering Series Page 56

Use coolant spray to determine which oscillator is contributing the most to the harmonic of concern

Page 29: Top Ten EMC Problems with EMC Troubleshooting Ver 1 · PDF file3 EMC Engineering Series Page 5 2a. Poor Cable Grounding RF Immunity problems almost always involves a cable ¾Shield

29

EMC Engineering Series Page 57

Example Of A Polar Plot - Wide Lobes

Emissions are coming fromthe sides of the product.

Single- or double-lobed plotis typical behavior at thelower frequencies (<300 MHz).

Probably due to cable radiation.

Polar plot at 216 MHz. Shape indicates a half-wavedipole antenna pattern.

EMC Engineering Series Page 58

Typical Polar Plot At Higher Frequencies -Narrow Lobes

Emissions are coming fromall around the product

Typical behavior at thehigher frequencies (>300 MHz)

Probably due to slot radiation.

Polar plot at 848 MHz. Pattern probably indicatesslot radiation and multiple reflections.

Page 30: Top Ten EMC Problems with EMC Troubleshooting Ver 1 · PDF file3 EMC Engineering Series Page 5 2a. Poor Cable Grounding RF Immunity problems almost always involves a cable ¾Shield

30

EMC Engineering Series Page 59

Using a loop probe to measure resonances

Roleson, Finding EMI Resonances in Structures, EMC Test & Design, Jan/Feb 1992

EMC Engineering Series Page 60

Resonance measurement

Roleson, Finding EMI Resonances in Structures, EMC Test & Design, Jan/Feb 1992

Page 31: Top Ten EMC Problems with EMC Troubleshooting Ver 1 · PDF file3 EMC Engineering Series Page 5 2a. Poor Cable Grounding RF Immunity problems almost always involves a cable ¾Shield

31

EMC Engineering Series Page 61

External clip lead

Useful for assessing proper signal return (or shield) connection back to enclosureConnect 1m-long clip lead to various shield connection points on all I/O cable portsClamp a current probe around the cable (or measure the amount of radiated emissions)If no current is detected or the clip lead has no effect on radiated emissions, that specific shield connection point is connected back to enclosure shielding OK

EMC Engineering Series Page 62

Plated shield conductivity measurement

Use of a “four-point” probe allows you to verify the sheet resistance, and hence the thickness of vapor-deposited (or plated) metallic shieldsA four-terminal (for resistance) DMM is requiredBy knowing the thickness, you can calculate the shielding effectiveness, given the manufacturer’s equation

Page 32: Top Ten EMC Problems with EMC Troubleshooting Ver 1 · PDF file3 EMC Engineering Series Page 5 2a. Poor Cable Grounding RF Immunity problems almost always involves a cable ¾Shield

32

EMC Engineering Series Page 63

Simple ESD Source – Coins In ZipLok Bag (Simulates Pocket Change)

Idea, courtesy of Doug Smith (www.emcesd.com)

Produces 200 ps rise timepulses of several volts

EMC Engineering Series Page 64

Simple ESD Source – Spark Gap Ruler

Idea, courtesy of Doug Smith (www.emcesd.com)

Produces 200 - 500 ps rise timepulses of several volts

Page 33: Top Ten EMC Problems with EMC Troubleshooting Ver 1 · PDF file3 EMC Engineering Series Page 5 2a. Poor Cable Grounding RF Immunity problems almost always involves a cable ¾Shield

33

EMC Engineering Series Page 65

EMC Management Recommendations•Identify a regulatory point of contact within the design team•Develop EMC design goals (6 dB margin for sample of five)•Perform margin testing, rather than testing to limits•EMC engineer is a part of the project management team•Make early design reviews part of the product generation process