tomba fascia matrix and technical information

14
Kitchen fascia matrix for Tomba 06 Unit permutations and setting out TOMBA BASE AND WALL DOOR/DRAWER (HORIZONTAL CHAMFER) TOMBA TOWER DOORS (VERTICAL CHAMFER) TOMBA CURVED AND CORNER DOORS METRIS FEATURE BASE UNITS Metris Concave curved wall unit door T: 01325 505599 (North) | 88 (South) F: 01325 505598 (North) | 89 (South) ORDER ONLINE www.pws.co.uk NOTE. ( ) INDICATES OVERALL CABINET DIMENSIONS

Upload: phammien

Post on 15-Jan-2017

229 views

Category:

Documents


6 download

TRANSCRIPT

Page 1: Tomba fascia matrix and technical information

Kitchen fascia matrix for Tomba 06 Unit permutations and setting out

TOMBA BASE AND WALL DOOR/DRAWER (HORIZONTAL CHAMFER)

TOMBA TOWER DOORS (VERTICAL CHAMFER)

TOMBA CURVED AND CORNER DOORS

METRIS FEATURE BASE UNITS

Metris Concave curved wallunit door

T: 01325 505599 (North) | 88 (South)

F: 01325 505598 (North) | 89 (South)ORDER ONLINEwww.pws.co.uk

NOTE. ( ) INDICATES OVERALL CABINET DIMENSIONS

Page 2: Tomba fascia matrix and technical information

Door combinations for Tomba 07 Suggested handleless door/drawer combinations to be used with larder units and appliance housing (600mm wide)

T: 01325 505599 (North) | 88 (South)

F: 01325 505598 (North) | 89 (South)ORDER ONLINEwww.pws.co.uk

Page 3: Tomba fascia matrix and technical information

Profile for wall cabinets, GPW3900 3900x19.6x20mm

Wall curved profile for 300x300mm GPCWS300SD curved door

Wall curved profile for 600x600mm GPCWSIC600 concave wall cabinet

Wall curved profile pack for 1200mm GPCWSCAVE concave wall cabinet, 3piece set

GPM4100 Mid profile for drawers, 4100x73x26mm

Curved concave mid profile for GPCMSCAVE drawers to suit 1200x1200mm cabinet

GPMIN90 Mid profile, internal corner joint 90°

GPMEND End caps for drawer profile, pair, lh/rh

Top profile for doors, GPT4100 4100x56.5x27.2mm

Curved concave top profile to suit GPCTSCAVE 1200x1200mm cabinet

Curved convex top profile to suit GPCTSVEX 1200x1200mm cabinet

Curved convex top profile to suit GPCTSVEX900 1500x1500mm cabinet

Curved top profile for 300x560mm GPCTS560SDL curved base cabinet, left hand (can be cut down for 300x300mm applications)

Curved top profile for 300x560mm GPCTS560SDR curved base cabinet, right hand (can be cut down for 300x300mm applications)

Curved top profile for 410x430mm GPCTS560L curved base cabinet, left hand (size inc 150 pull-out)

Curved top profile for 410x430mm GPCTS560R curved base cabinet, right hand (size inc 150 pull-out)

Curved top profile for 900x900mm GPCTIC900 concave corner base cabinet

Curved top profile for 600mm GPCTS600L 'S' Shaped door L/H base cabinet

GPCTS600R Curved top profile for 600mm 'S' Shaped door R/H base cabinet

GPTEX90 Top profile, external corner joint 90°

GPTIN90 Top profile, internal corner joint 90°

GPTEND End caps for top profile, pair, lh/rh

GPTJOINT Mid Joint section for top profile

09ORDER ONLINEwww.pws.co.uk

Aluminium rail profiles for Tomba

TOP RAIL PROFILES MID RAIL PROFILES

WALL RAIL PROFILES

VERTICAL PROFILES FOR LARDERS/APPLIANCES

GPV2250MID Vertical profile (intermediate), 2250x66.6x42mm, trim to size

GPV2250END Vertical profile (lateral), 2250x48.3x42mm trim to size

GPV2250APP Vertical profile (for appliances), 2250x30x42mm, trim to size

SECURING BRACKETS FOR TOP AND MID RAILS GPFIXING Securing brackets for top and mid supports, black, pack 2 (sold in box quantities of 50)

Page 4: Tomba fascia matrix and technical information

32

57.5

422

.5

37

18mmcabinettop panel

R5

27

Routing cabinet detailS

crew

pos

ition

s

T: 01325 505599 (North) | 88 (South)

F: 01325 505598 (North) | 89 (South)

10TECHNICAL GUIDE

SEE PAGE 13 FOR DETAILS ON FITTING RAIL PROFILES TOCABINETS WITH SECURING BRACKETS (GPFIXING).

• The top rail profile for base unit doors/drawers is availablein straight lengths of 4.1m (GPT4100) and in set curvedsections (see page 9).

• Single straight rail lengths are cut down to size (using acircular chop saw) to fit the requested number of cabinets.

• Securing brackets to fit rail profiles to cabinets and must beordered separately in sets of 25 pairs (GPFIXING).

TOMBA DOOR Aluminium Top rail profile

ADDITIONAL OPTIONS:A range of joints and end caps are alsoavailable for top and mid rail profiles.

57.5

34

684.

5

720

900

56.5

27.2Overall cabinet dimensions

Rail profile

Worktop

Top Rail Profile (GPT4100)

CabinetTop Panel

Securing Brackets(GPFIXING)

Door/drawer

Fitted rail detail

TOP RAIL PROFILECABINET DETAILS

Page 5: Tomba fascia matrix and technical information

11ORDER ONLINEwww.pws.co.uk

Aluminium rail profiles for Tomba

• The mid rail profile for base unit drawers is available in straightlengths of 4.1m (GPM4100) and in a curved section for theconcave drawer pack in 1200x1200mm cabinets (GPCMSCAVE).

• Single straight rail lengths are cut down to size (using a circularchop saw) to fit the requested number of cabinets.

• Securing brackets to fit rail profiles to cabinets and must beordered seperately in sets of 25 pairs (GPFIXING).

TOMBA DOOR Mid rail profile

ADDITIONAL OPTIONS:An internal corner joint (GPMIN90) and end cap(GPMEND) are available separately

MID RAIL PROFILE AND CABINET DETAILS

73

73

3220

.520

.5

26

R5

R5

37

27

Routing cabinet detail Rail profile

Cabinet

Door/drawer

Trim (GPM4100)SecuringBrackets(GPFIXING)

Door/drawer

Fitted rail detail

Scr

ew p

ositi

ons

280

309.

573

160

160

325

870

150

900

57.5

280

309.

573

325

325

870

150

900

57.5

57.5 34

34

34

34 34

34

122

467.

573

160

490

870

150

900

Page 6: Tomba fascia matrix and technical information

89

min. 90max. 220*

100

53

598550

T: 01325 505599 (North) | 88 (South)

F: 01325 505598 (North) | 89 (South)

12TECHNICAL GUIDE

DISHWASHER/CABINET DETAILS

UNDERMOUNTED OVEN APPLICATIONS

Worktop

Securing Brackets(GPFIXING)

DishwasherDoor/drawer

Trim

815-

875*

• The top rail profile (GPT4100) can be used whenplanning a dishwasher into base cabinets.

PLEASE NOTE: XXL dishwasher models can not be usedwith rail profiles, instead a 815-875mm fully integrateddishwasher needs to be used for this application to allowheight adjustment for the appliance to sit under the rail.

TOMBA DOOR Rail profiles for dishwasher applications

Metal brackets (supplied with dishwasher)should be fixed to the outer face of adjacentcabinets. Please Note: an additional bracingbaton may be required to the rear of themachine to help reduce movement.

A top rail profile can not be used in conjunctionwith an under-mounted oven. Rails must stop oneach side of the appliance. They can be finishedwith GPTEND & GPMEND end caps.

Depending on the design of the oven, end panelswill need to be fitted either side of the applianceand the rail profile terminated against the panel.

Fitted rail detail

Illustration shows an example of handleless rail profiles(with end caps) terminating against an oven

Page 7: Tomba fascia matrix and technical information

13ORDER ONLINEwww.pws.co.uk

Aluminium rail profiles for Tomba

Routing cabinet detail for top profile

• Securing brackets (GPFIXING) are required to fit both top andmid rail profiles to cabinets and must be ordered seperately tothe rail profiles (supplied in packs of 50).

TOMBA DOOR Securing brackets for top and mid rail profiles

FITTING TOP RAIL PROFILES

Routing cabinet detail for mid profile

FITTING MID RAIL PROFILES

73

3220

.520

.5

R5

R5

37

26

Scr

ew p

ositi

ons

GPFIXING

1. Router cabinet gable ends for top rail profile and mark screw positions.

2. Screw securing brackets into place. 3. Slide ‘H’ connector into runner onback of rail trim, sit rail on routedgable ends and slide connector toclip into the securing bracket andhold rail in place.

1. Router cabinet gable ends for mid rail profile and mark screw positions

2. Screw securing brackets into place 3. Slide ‘H’ connector into runner onback of rail trim, sit rail on routedgable ends and slide connector toclip into the securing bracket andhold rail in place.

Page 8: Tomba fascia matrix and technical information

T: 01325 505599 (North) | 88 (South)

F: 01325 505598 (North) | 89 (South)

14TECHNICAL GUIDE

When applying a corner post or internal corner doors, a top internal corner joint is required for two top profilesto run into. The internal corner joint section is supplied with two screws which when in position secure the jointto the rail profiles.

End caps can be used when top rail trims come to an end (e.g. against a wallor end panel next to appliances). A screw is supplied to attach the end capfirmly to the rail.

GPINT90

GPTEND(L/R pair)

GPTJOINT

5mm

TOMBA DOOR Top profile internal corner joint 90º (for use with GPT4100)

End caps top profile, pair, lh/rh (for use with GPT4100)

A mid joint section is available to hide joints in certain applicationswhere two top rail profiles meet (e.g. when a straight rail profilemeets a curved rail section).

Mid joint section for top profile (for use with GPT4100)

PLEASE NOTE: When using end caps, a2mm spacing must betaken in to account (whencutting down the trim).

PLEASE NOTE: When using mid joints, a 5mm spacing must be taken into account whencutting down the rail profiles that are being joined at either side.

Front view

Rear view

Page 9: Tomba fascia matrix and technical information

15ORDER ONLINEwww.pws.co.uk

Aluminium rail profiles for Tomba

PLEASE NOTE: When using end caps, a 2mm spacing must be taken in to account.

An external corner joint is available when running top rail profiles around an island or corner. The externalcorner joint is supplied with two screws, which when in position, secure the joint firmly to the rail profile.

TOMBA DOOR Top profile external corner joint 90º (for use with GPT4100)

GPTEX90

When joining two mid rail profiles in a corner application a mid profile internal corner joint is required fortwo mid profiles to run in to. The internal corner joint is supplied with two screws which when inposition secure the joint to the rail profiles.

Mid profile internal corner joint 90º (for use with GPT4100)

End caps can be used when mid rail trims come to an end (e.g. against a wall or end panel next toappliances). A screw is supplied to attach the end cap firmly to the rail.

End caps for mid drawer profile, pair, lh/rh (for use with GPT4100)

GPMIN90

GPMEND

Page 10: Tomba fascia matrix and technical information

T: 01325 505599 (North) | 88 (South)

F: 01325 505598 (North) | 89 (South)

16TECHNICAL GUIDE

FITTING WALL RAIL PROFILES

Door

Trim (GPW3900)

Routed Groove

Cabinet

Wall rail profileRouting cabinet detail Fitted rail detail

7.5

7.5

3

18

8 19.6

8

20.8

20

GPW3900 GPCWS300SDGPCWSIC600 GPCWSCAVE

• Rail profiles for wall units are available in straight lengths of 3.9m(GPW3900) as well as curved rail sections.

• Single straight rail lengths are cut down to size (using a circularchop saw) to fit between gables.

TOMBA DOOR Profiles for wall cabinets

The base panel of the wall unit needs to be set back20.8mm to accommodate the rail profile within theoverall depth of the cabinet.

A groove (3.2mm high, 8mm deep) must then berouted into the base panel using slotting cutters.

The rail profile then slots into the routed groove(clear silicon adhesive should be used to bind therail with the panel).

20.8

Cabinet

Base panelTrend C143X1/4 TC

3.2mm (recommendedslotting cutters)

Cabinet

Fitted rail profile

Page 11: Tomba fascia matrix and technical information

17ORDER ONLINEwww.pws.co.uk

Aluminium rail profiles for Tomba

• The vertical intermediate profile (GPV2250MID) shouldbe used in the scenario where two opening doors meet.Due to the width and placement of the trims, a 30mmspacer is required at the back between the two cabinetsto maintain the space created by the trim.

• The front of the gables on the cabinets need to be setback by 12mm for the trim to overlap behind the doors.

• The trim is securely fixed to the cabinets with 4x 30mmcountersunk screws.

TOMBA DOOR Vertical profile (intermediate)

Vertical profile (intermediate),2250x66.6x42mm, trim to size

GPV2250MID

Rail application between two opening doors Fitting detail

Cabinet Cabinet

Spacer

Trim

Appliance/door

32

4x 30mmscrews

4x 30mmscrews

20

2032

12

12

30

When joining cabinets in larder runs, a spacer isneeded at the back to maintain the 30mm voidcreated by the trim profile. The spacer is screwfixed to the cabinets from the inside of eachcabinet.

NOTE: Try to position the screw holes in the cabinetso they are concealed (such as behind hinge plates)when internal components are added. When planningappliance housings don’t forget to allow 30mmbetween units where access to a handle is required.

Page 12: Tomba fascia matrix and technical information

T: 01325 505599 (North) | 88 (South)

F: 01325 505598 (North) | 89 (South)

18TECHNICAL GUIDE

Vertical profile (lateral),2250x48.3x42mm, trim to size

GPV2250END

• The vertical lateral profile (GPV2250END) should beused in the scenario where you have an opening door toone side and don’t require access to a handle on theopposite side. It can also be used to end a run where anend panel or accessory is fitted.

• Due to the width and placement of the trims, a 30mmspacer is required at the back between the two cabinetsto maintain the space created by the trim.

• The front of the gable on the cabinet needs to be setback by 12mm for the trim to overlap behind the door.

• The trim is securely fixed to the cabinets with 4x 60mmcountersunk screws.

TOMBA DOOR Vertical profile (lateral)

Rail application between opening door and endpanel/post or hinge side of adjacent door

Fitting detail

When joining cabinets in larder runs, a spacer isneeded at the back to maintain the 30mm voidcreated by the trim profile. The spacer is screwfixed to the cabinets from the inside of eachcabinet.

NOTE: Try to position the screw holes in the cabinetso they are concealed (such as behind hinge plates)when internal components are added.

Cabinet

Featureendpost

Cabinet

Spacer

Endpost

Trim

Door

4x 60mmscrews

Adhesive

2012

32

61

Page 13: Tomba fascia matrix and technical information

19ORDER ONLINEwww.pws.co.uk

Aluminium rail profiles for Tomba

Vertical profile (for appliances),2250x30x42mm, trim to size

GPV2250APP

• The vertical appliance profile (GPV2250APP) should beused where no handle access is required or where theoven housing meets an end panel. This rail may not beessential from a fitting perspective, but used more foraesthetical purposes to carry on the look with otheraluminium rails on the run of units.

• Due to the width and placement of the trims, a 30mmspacer is required at the back between the two cabinetsto maintain the space created by the trim.

• As the appliance trim profile has no detailed ends, thegable of adjacent cabinets do not need to be set back.

• The trim sits flush with the front of the gable ends andthe trim is securely fixed to the cabinets with 4x 60mmcountersunk screws.

TOMBA DOOR Vertical profile (for appliances)

Rail application between hinged door sideand end panel/post

Fitting detail

When joining cabinets in larder runs, a spacer is neededat the back to maintain the 30mm void created by thetrim profile. The spacer is screw fixed to the cabinetsfrom the inside of each cabinet.

NOTE: Try to position the screw holes in the cabinetso they are concealed (such as behind hinge plates)when internal components are added.

Featureendpost

Cabinet

Spacer

Endpanel

Trim

Door

4x 60mmscrews 32

61

Page 14: Tomba fascia matrix and technical information

T: 01325 505599 (North) | 88 (South)

F: 01325 505598 (North) | 89 (South)

Tomba curved door selection 08TECHNICAL GUIDE

Small curvedwall door

Small curveddoor

Large curveddoor

Internal curved wall door(for 600x600mm wall unit)

Concave curved wall door(for 1200x1200mm wall unit)

Concave curved base doorInternal curved base door(for 900x900mm base unit)

Convex curved door(for 900mm deep curved island)

Convex curved panel

Concave curved drawer packRipple curve drawer front‘S’ Shaped doorCurved glazed wall unit(n/a in paint to order)

Handleless door available in gloss white from stock and paint to order (matt & gloss options)