toc analyser - minitoc-arrowlabs.net/resources/brochures/minitoc short presentation.pdf · toc...

19
TOC Analyser - MiniTOC- membraPure GmbH Wolfgang-Küntscher Straße 14 16761 Hennigsdorf

Upload: others

Post on 17-Oct-2020

6 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: TOC Analyser - MiniTOC-arrowlabs.net/resources/brochures/MiniTOC short presentation.pdf · TOC Analyser measurement range 0.1 - 1000 ppb cell constant accuracy 1.5% temperature sensor

TOC Analyser - MiniTOC-

membraPure GmbH Wolfgang-Küntscher Straße 14

16761 Hennigsdorf

Page 2: TOC Analyser - MiniTOC-arrowlabs.net/resources/brochures/MiniTOC short presentation.pdf · TOC Analyser measurement range 0.1 - 1000 ppb cell constant accuracy 1.5% temperature sensor

membraPure GmbH founded 1993

office building production hall Product range:

2 22.11.2018

Page 3: TOC Analyser - MiniTOC-arrowlabs.net/resources/brochures/MiniTOC short presentation.pdf · TOC Analyser measurement range 0.1 - 1000 ppb cell constant accuracy 1.5% temperature sensor

TOC Analyser

measurement range 0.1 - 1000 ppb

cell constant accuracy 1.5%

temperature sensor : PT 1000

temperature accuracy: +/- 0.25 K

ports 1 for sample, 1 for SST (Basic)

1 for sample, 3 for SST (Professional)

max. conductivity of sample:

< 2 μS/cm (online)

3 22.11.2018

Page 4: TOC Analyser - MiniTOC-arrowlabs.net/resources/brochures/MiniTOC short presentation.pdf · TOC Analyser measurement range 0.1 - 1000 ppb cell constant accuracy 1.5% temperature sensor

TOC Analyser

sample volume flow 14 ml/min

analysis time 2 sec

inlet pressure < 0.5 bar otherwise

pressure reducer

sample temperature 10 - 50 °C if

more than heat exchanger

particles < 100 micron

4 22.11.2018

Page 5: TOC Analyser - MiniTOC-arrowlabs.net/resources/brochures/MiniTOC short presentation.pdf · TOC Analyser measurement range 0.1 - 1000 ppb cell constant accuracy 1.5% temperature sensor

TOC Analyser

Housing

dimensions (w x d x h)

300 mm x 200 mm x 500 mm

weight 14 kg

protection: IP 54 (option)

Operating Conditions

power supply 110 - 230 VAC, 50 Hz

power consumption < 50 W

ambient relative humidity 10 - 95 %

altitude : up to 3500 m 5 22.11.2018

Page 6: TOC Analyser - MiniTOC-arrowlabs.net/resources/brochures/MiniTOC short presentation.pdf · TOC Analyser measurement range 0.1 - 1000 ppb cell constant accuracy 1.5% temperature sensor

TOC Analyser

Configuration

control internal PC, 8“ TFT touch screen

monitor

operating system Windows 7 embedded

software miniTOC control software for

measurement, qualification, diagnosis

interfaces USB 2.0, analogue out (option)

6 22.11.2018

Page 7: TOC Analyser - MiniTOC-arrowlabs.net/resources/brochures/MiniTOC short presentation.pdf · TOC Analyser measurement range 0.1 - 1000 ppb cell constant accuracy 1.5% temperature sensor

Design

UV-Reactor

Pump

Conductivity sensors

Valves

7 22.11.2018

Page 8: TOC Analyser - MiniTOC-arrowlabs.net/resources/brochures/MiniTOC short presentation.pdf · TOC Analyser measurement range 0.1 - 1000 ppb cell constant accuracy 1.5% temperature sensor

Scheme fluidic

8 22.11.2018

Page 9: TOC Analyser - MiniTOC-arrowlabs.net/resources/brochures/MiniTOC short presentation.pdf · TOC Analyser measurement range 0.1 - 1000 ppb cell constant accuracy 1.5% temperature sensor

Fluid connections

9 22.11.2018

Page 10: TOC Analyser - MiniTOC-arrowlabs.net/resources/brochures/MiniTOC short presentation.pdf · TOC Analyser measurement range 0.1 - 1000 ppb cell constant accuracy 1.5% temperature sensor

Menu

10 22.11.2018

Page 11: TOC Analyser - MiniTOC-arrowlabs.net/resources/brochures/MiniTOC short presentation.pdf · TOC Analyser measurement range 0.1 - 1000 ppb cell constant accuracy 1.5% temperature sensor

Online measurement

11 22.11.2018

Page 12: TOC Analyser - MiniTOC-arrowlabs.net/resources/brochures/MiniTOC short presentation.pdf · TOC Analyser measurement range 0.1 - 1000 ppb cell constant accuracy 1.5% temperature sensor

Calibration - start

12 22.11.2018

Page 13: TOC Analyser - MiniTOC-arrowlabs.net/resources/brochures/MiniTOC short presentation.pdf · TOC Analyser measurement range 0.1 - 1000 ppb cell constant accuracy 1.5% temperature sensor

Calibration- finished

Factor & R²

Measured data

Calibration curve

13 22.11.2018

Page 14: TOC Analyser - MiniTOC-arrowlabs.net/resources/brochures/MiniTOC short presentation.pdf · TOC Analyser measurement range 0.1 - 1000 ppb cell constant accuracy 1.5% temperature sensor

SST - start

14 22.11.2018

Page 15: TOC Analyser - MiniTOC-arrowlabs.net/resources/brochures/MiniTOC short presentation.pdf · TOC Analyser measurement range 0.1 - 1000 ppb cell constant accuracy 1.5% temperature sensor

Viewer

15 22.11.2018

Page 16: TOC Analyser - MiniTOC-arrowlabs.net/resources/brochures/MiniTOC short presentation.pdf · TOC Analyser measurement range 0.1 - 1000 ppb cell constant accuracy 1.5% temperature sensor

Interval Mode MiniTOC pro

16 22.11.2018

Page 17: TOC Analyser - MiniTOC-arrowlabs.net/resources/brochures/MiniTOC short presentation.pdf · TOC Analyser measurement range 0.1 - 1000 ppb cell constant accuracy 1.5% temperature sensor

Service Change UV-Reactor: Plug out power supply Remove plug connection Unscrew fluidic tubes Take reactor out of holder

Change pump tube: Open cable ties Remove fluidic lines from

pump tube Open pump clamps, remove

tube by turning pump manually

Reset hourmeters for pump tube and UV Lamp!!

17 22.11.2018

Page 18: TOC Analyser - MiniTOC-arrowlabs.net/resources/brochures/MiniTOC short presentation.pdf · TOC Analyser measurement range 0.1 - 1000 ppb cell constant accuracy 1.5% temperature sensor

Installation

waste

Cooler (if T > 50 °C)

Option:

Pressure reducer

p ≈ 0.25 bar

connector ¼“ -28 UNF

connector ¼“ BSP x 6 mm

Water Connection

connector

Gate valve with

Adapter 6 mm

Tube 6 mm AD

Tube 1/8“ 3.2 mm AD

18 22.11.2018

Page 19: TOC Analyser - MiniTOC-arrowlabs.net/resources/brochures/MiniTOC short presentation.pdf · TOC Analyser measurement range 0.1 - 1000 ppb cell constant accuracy 1.5% temperature sensor

Installation

19 22.11.2018