to be more comfortable near vision life nikon “web.lens”
TRANSCRIPT
To be more comfortable near vision life
Nikon “web.lens”
Complaint for reading glass
1.Complaint (survey in Japan market)
0% 10% 20% 30% 40% 50% 60% 70%
No comment
Other reason
Narrow eye sight
Can see only one point
Tired for long wearing time
Bother to change glasses
1.Complaint for progressive (survey in Japan market)
0% 10% 20% 30% 40% 50% 60%
No comment
Other reason
Hard to see mid distance area
Complaint with distotion
Hard to see near vision for long time
Hard to move sight from up to down
Very tired to use long time
Complaint for progressive lens
Distance
Advantage of “PAL + web.lens” Dual UseAdvantage of “PAL + web.lens” Dual Use
PerfectAccommodation
Intermediate
Near
Vision of presbyopia
SingleVision
SingleVision
SingleVision
PAL PAL PAL
web.lens web.lens web.lens
The Best Correction
Benefit of “web.lens” compare to PAL
Web.lensWeb.lens ProgressiveProgressive
大
小大
小
・ ・ Wider near areaWider near area
・ ・ Natural Near Eye sight: Very close to the eye pointNatural Near Eye sight: Very close to the eye point
・ ・ Small eye-ball rotation:easy to focus the pintSmall eye-ball rotation:easy to focus the pint
Proposal to wear PAL + “web.lens”Proposal to wear PAL + “web.lens”
Do explain what is the benefit of each lensDo explain what is the benefit of each lens
If your patient chose one lens ---If your patient chose one lens --- You should always explain the benefit of another type You should always explain the benefit of another type
If your patient want to buy reading glass---If your patient want to buy reading glass--- You should always explain the benefit of “web.lens”You should always explain the benefit of “web.lens”
How to sell web.lensHow to sell web.lens
1. Up-graded reading glass Reading glass Nikon
web.lens2. Second multi-focal glasses
Nikon Presio I + Nikon web.lens or Varilux Panamic + Nikon web.lens
Sell more lenses and frames at the same time
Providing The Best DesignProviding The Best Design
Web.lens
Best matching for your desk work
Wide Near Vision
web.lens designweb.lens design
5mm
4mm
10mmDegression
Zone
““web.lens” sight imageweb.lens” sight image
Invariable Intermediate Zone
Degression Zone
Invariable Near Vision Zone
2 Materials and 2 Types2 Materials and 2 Types
1.50 CR39 1.67 UHI
TYPE 1Degrs. –1.00
Web.lensCP1
Web.lensFP1
TYPE 2Degrs. –1.50
Web.lensCP2
Web.lensFP2
Choice of Type
Degression Near Vision Depth of NV optimum addition
TYPE 1 -1.00 D Wide 2.00 D and lower
TYPE 2 -1.50 D Deep 2.25 D and higher
2 STEP1) Select according to addition value2) Select according to specific needs
1) PD : Align web.lens Fitting Point with the near PD.
2) Eye point height : Align web.lens Fitting Point with the Eye point height for NV.
3) Minimum frame size : To assure the patient to enjoy the wide near vision of web.lens, we recommend maintaining aminimum of 15 mm between the FP and the bottom of the frame rim. A shorter distance will make it difficult to assure thesame Near Vision as reading SV lenses. The absolute minimum is 12 mm.Unlike PALs, web.lens has a Degression area above the FP. Be sure to check if the upper is not cut off. We recommendmaintaning a minimum of 20 mm between the FP and the top of the frame rim. A shorter distance will make it difficult toassure the same vision as what the patient has experienced with the web.lens trial lens. The absolute minimum is 15 mm.
Alignment of web.lens < basic method>
Recommended height
If it is impossible to measure the Eye point height for NV or near vision PD and the FarVision Eye point is used as the reference for framing, we recommend matching the "virtual"Far Fitting Point to the Eye point for FV.This is because that compared to Far Vision, Near Vision usually has a smaller PD and theline of sight is lower.
The standard expression of the Far Eye point is:Eye point for NV= 2 mm inside and 4 mm below the Eye point for FV.
It is not a very acurate measurement method, but, in most cases, web.lens Near Vision is wide enough to cover it.
Alignment of web.lens < PAL method>
Power on each pointPower on each point
E.g.: near vision power 2.00D
TYPE-1 TYPE-2 Calculation
Degression -1.00 -1.50
Distance Point +1.00 +0.50 +2.00 + (Deg) =100%
Far Fitting point +1.50 +0.75 +2.00 +9/19X (Deg) =50%
Fitting Point +1.75 +1.62 +2.00 + 5/19X(Deg) =25%
Near Point +2.00 +2.00 +2.00 + 0/19X(Deg) = 0%
AVAILABLE RANGE
Near to intermediate change 1.00D
+5.50 to –8.00 sph; -4.00 cyl to combined power –4.00
Nikon web.lens I
1.67
Near to intermediate change 1.00D+5.50 to –4.00 sph;
-4.00 cyl to combined power –8.00
Nikon web.lens I
1. 50
Near to intermediate change 2.00D
Near to intermediate change 1.50D
Nikon web.lens II
Near to intermediate change 1.50D
Nikon web.lens II
AdditionPower rangeProductIndex
Nikon web.lens III
Recommend for the occupationRecommend for the occupation
Recommend for the hobbyRecommend for the hobby
Case study
E.g. 55 YearsE.g. 55 Years(Perfect, accommodation 2D, add+2.00D)(Perfect, accommodation 2D, add+2.00D)
Stable intermediate
Far fitting Point
Near fitting Point
Near Point
NP
33cm100cm
25cm50cm
Type 1
+1.00D
+1.50D
+1.75D
+2.00D
NP
∞∞50 cm
In case of prescribing near point at 25cm
Reading glass25- 50cm
E.g. 55 YearsE.g. 55 Years(Perfect, accommodation 2D, add+2.00D)(Perfect, accommodation 2D, add+2.00D)
Stable intermediate
Far fitting Point
Near fitting Point
Near Point
25cm50cm
Type 2
+0.50D
+1.25D
+1.625D
+2.00D
NP
∞∞50 cm
In case of prescribing near point at 25cmNP
40cm200cm
Reading glass25- 50cm
Improved Field of Vision
Reading glass
Web.lens Type1
25cm to 100 cm
25cm to 200 cm
Web.lens Type2
25cm to 50cm
< Case Study>55 years old
SOLA Access Field of Vision
Access A
25cm to 80 cm
25cm to 133 cm
Access B
Web.lens Type1
25cm to 100 cm
25cm to 200 cm
Web.lens Type2
E.g. 65 YearsE.g. 65 Years(Perfect, accommodation 1.0D, add+3.00D)(Perfect, accommodation 1.0D, add+3.00D)
Stable intermediate
Far fitting Point
Near fitting Point
Near Point
NP
40cm
25cm33cm
Type 2
+1.50D
+2.25D
+2.625D
+3.00D
NP
∞∞100 cm
Reading glass25- 33cm
67cm
In case of prescribing near point at 25cmFP
Improved Field of Vision
Reading glass
Web.lens Type1
25cm to 50 cm
25cm to 100 cm
Web.lens Type2
25cm to 33cm
< Case Study>65 years old
SOLA Access Field of Vision
Access A
25cm to 44 cm
25cm to 57 cm
Access B
Web.lens Type1
25cm to 50 cm
25cm to 67 cm
Web.lens Type2
Design comparison/ Astigmatism Line
SOLA Access B Web.lens type1 Web.lens Type2
Prescription ; S+2.00D
Dirges; -1.25D Dirges; -1.00D Dirges; -1.50D
SOLA Access B Web.lens type1 Web.lens type2
Prescription ; S+2.00D
Digres; -1.25D Digres; -1.00D Digres; -1.50D
Design comparison/ Power Line
WEB.LENS Trial Set
1.00DR
19mm
Specifications :
3 engraved marks are on the rim.these engraved marks indicate fitting pointand fitting height
Usage :To use trial frame which can adjust fitting point
up-and-down, right-and-left. (1) Set this trial lens into trial frame a. Trial lenses should be set in front holder of trial frame b. Grip of the trial lens should be positioned at the ear-side upwards. Point a. must be adjusted on 90º of trial frame. Line b-c must be adjusted 0 -180 º line of trial frame.(2) adjust optical center with patient a. optical center must be fit with near P.D. b. optical center must be fit with near height
aa
bC
Picture Yourself in Nikon lensesPicture Yourself in Nikon lenses