Page 1: TM 9-1425-381-10-8

DEPARTMENT OF THE ARMY TECHNICAL M A N U A L

OPERATOR'S MANUAL DUTIES OF HORIZONTAL LAYING THEODOLITE, VERTICAL LAYING

THEODOLITE AND ORfENTJNG STATION THEODOLITE OPERATORS

PERSHING l a FIELD ARTILLERY MISSILE SYSTEM

HEADQUARTERS DEPARTMENT OF THE ARMY

APRIL 1972

Page 2: TM 9-1425-381-10-8

I WARNING 1

OPERATION OF THIS EQUIPMENT MAY BE HAZARDOUS

To insure adequate protection to personnel and equ~pment, operators must become famiilar with proper use of the following as defined ~n TM 9- 1425-381-10:

High-pressure alr systenls Hazardous solvents Toxic and flammable chemicals Dangerous noise levels Dangerous electrical voltages

Page 3: TM 9-1425-381-10-8

TECHNICAL MANUAL HEADQUARTERS DEPARTMENT OF THE ARMY

NO. 9- 1 4 2 5 - 3 8 1 - 1 0 - 8 WASHINGTON, D.C.

21 A p r 72

DUTIES OF HORIZONTAL LAYING THEODOLITE, VERTICAL LAYING

THEODOLITE AND ORIENTING STATION THEODOLITE OPERATORS

TABLE OF CONTENTS Par Page

Chapter 1. Introduction

General . . . . . . . . . . . . . . . . . . . . . . . . 1 1 1 - 1 Purpose- . . . . . . . . . . . . . . . . . . . 1 - 2 1 - 1 Scope . . . . . . . . . . . . . . . . . . . . . . . 1 3 1 . 1 Use of Manual . . . . . 1 4 1 - 2

Chapter 2. Missile Assembly and Warhead Section Handling

Sectlor1 I M iss~ le Assembly

D u t ~ e s of HLT OP . . . . . . . . . 2 1 2 2 - 0 D u t ~ e s of OST O P . . . . . 2 - 1 3 2 - 2

T h ~ s manual supersedes TM 9 1425 381 10 8 30 June 1971

Page 4: TM 9-1425-381-10-8

TABLE OF CONTENTS (Cont)

Par. Page

Chapter 3. Procedures for Performing Confidence or Standard Count

Section I. Conf~dence or Standard Count

Duties of HLT OP ............. 3 - 1 3 3-0 Dut ieso fOSTOP ............. 3 - 1 4 3 - 1 7

Chapter 4. Quick Count

Chapter 5. Postfiring and Missile Recapture Procedures

Section I. Post f~r ing Procedures

............. Duties of HLT OP 5 - 1 0 5 - 1

............. Du t~es of OST OP 5 - 1 1 5 - 3

Section II. Miss~ le Recapture and Warhead Section Removal Procedures

Duties of HLT OP ............. 5 - 2 1 5 - 4 D u t ~ e s of OST OP ............. 5 - 2 2 5-6

Page 5: TM 9-1425-381-10-8

TABLE OF CONTENTS (Cont)

Par. Page

Section I l l . Warhead Section Removal

Duties of HLT OP ............. 5.30 5 - 7 Duties of OST OP ............. 5 - 3 1 5 - 8

Chapter 6. Missile Disassembly Procedures

Section I. Missile Disassembly

Duties of HLT OP . . . . . . . . . . . . 6 - 9 6 - 1 Duties of OST OP ............. 6 - 1 0 6 - 5

Chapter 7. Operation Under Unusual Conditions

Sect~on I l l . Change of Target

Duties of VLT OP .............. 7 - 1 3 7 - 0 Dut~es of OST OP ............. 7 - 1 4 7 - 9

Page 6: TM 9-1425-381-10-8
Page 7: TM 9-1425-381-10-8

CHAPTER 1

INTRODUCTION

1- 1 . General

For information pertaining to nomenclature, abbrevia tions, publications improvements, and other general information, refer to TM 9 - 1 4 2 5 - 3 8 1 - 1 0 , For a listrng of forms, records, and reports pertaining to materiel covered in thrs manual, and rnstructions for therr use, refer to TM 3 8 - 7 5 0 .

1 - 2 . Purpose This manual IS for the use of the HLT, VLT, a n d OST

operators dur ing tactical operation of the PERSHING l a Field Artillery Missile System. It may b e used In con- junction with TM 9 - 1 4 2 5 - 3 8 1 - 1 0 , which contains pro- cedures In abbreviated tabular fo rm.

1-3. Scope

The procedures in thts manual are prrmari ly for op- e r a t ~ o n under usual cond i t~ons For operat ion under extreme envtronmental condi t ions, re fer t o TM 9 - 1 4 2 5 - 3 8 1 - 1 0 TM 9 - 1 4 2 5 3 8 1 - 1 0 - 2 through TM 9 - 1 4 2 5 - 3 8 1 - 1 0 - 7 and TM 9 - 1 4 2 5 - 3 8 1 - 1 0 - 9 contain procedures t o be per formed by o ther personnel

Page 8: TM 9-1425-381-10-8

Assembly Par. 2-12 HLT OP

1 - 4 . Use of Manual

Except f o r th is chapter, paragraphs are not num- bered sequential ly. The method of numbering has been selected so tha t the paragraph numbers in th is manual correspond t o the paragraph numbers in TM 9 - 1 4 2 5 - 3 8 1 - 1 0 . Thus, i f tables in TM 9 - 1 4 2 5 - 3 8 1 - 1 0 are being used, and deta i ls are required, i t is only necessary t o note the paragraph number in the appro- pr iate column o f the table heading, and then re fer t o the same paragraph number in th is manual fo r detai ls. Where references are made t o tables, f igures, and appendixes, re fer to those port ions of TM 9 - 1 4 2 5 - 3 8 1 - 1 0 .

CHAPTER 2

MISSILE ASSEMBLY AND WARHEAD SECTION HANDLING

Section I. MISSILE ASSEMBLY

2 - 1 2 . Dutiesof H L T O P

1 Drive aux i l~ary equ~pmen t vehicle into position as directed by OST OP; set veh~c le brakes.

2 Obtain tools f rom aux~ l ia ry equ~pment vehicle and d i s t r~bu te them as reauired.

Page 9: TM 9-1425-381-10-8

Assembly Par. 2-12

HLT OP

3 THRU

5

6 AND

7

8 THRU

10

12 AND 13

15 THRU 3 0

No ass~gned dutles.

Work~ng wlth other operators, remove condl- tloned-air duct, hlgh-pressure alrhose, and ca- ble bundle, and lay cond~tioned-a~r duct, l i ~ g h - pressure alrhose, and cable bundle as dlrected by supervisor

No asslgned dutles.

Asslst PS OP ~n guldlng 1st stage holsting beam from ground.

No asslgned dutles.

( 1 ) Asslst PS OP ~n guld~ng 2nd stage holst- ~ n g beam from ground.

( 2 ) Asstst OST OP ~n handllng gu~dance sect~on ho~st ing beam to MH 5 and 6.

No asslgned dutces.

Worklng wtth other operators , gulde cable bundle as CMA IS pos~tloned for ~nstallation; then postt~on bundle over center of blast de- flector.

2-1

Page 10: TM 9-1425-381-10-8

Assembly Par. 2-13 OST OP

32 No assigned duties AND 3 3

34 ( 1 ) Work~ng w ~ t h other operators, place and AND secure cable bundle and h~gh-pressure 35 a~rhose to left rear azimuth rlng pedestal,

across transporter below blast deflector, to r ~ g h t rear azimuth ring pedestal, and along right side of EL.

( 2 ) Place and secure cond~tioned-a~r duct across top of blast deflector and down r ~ g h t s ~ d e of EL.

36 No assigned dut~es AND 3 7

38 Assisted by PS OP, store all tools.

39 Drive aux~ l~ary equipment vehlcle out of area.

2- 13 . Duties of OST OP

1 Guide aux~liary equipment vehicle into position; then chock wheels.

2 Remove tools from toolboxes and place them THRU on rear of auxiliary equipment veh~cle. 4

5 No assigned dutres AND

6

Page 11: TM 9-1425-381-10-8

Assembly Par. 2-13

OST OP

8 THRU 13

15 THRU 30

3 2 AND 3 3

34 AND 35

Assist ~n gu~dlng CMA.

No assigned duties.

Assisted by HLT OP, hand gu~dance sectlon hoist~ng beam to MH 5 and 6.

No ass~gned dut~es.

Working with other operators, guide cable bundle as CMA is posit~oned for installation; then pos~tion bundle over center of blast de- flector.

No assigned duties

( 1 ) Working with other operators, place and secure cable bundle and high-pressure airhose to left rear azimuth ring ped- estal, across transporter below blast deflector, to right rear azimuth ring pedestal, and along r ~ g h t side of EL.

( 2 ) Place and secure conditioned-air duct across top of blast deflector and down right side of EL.

Page 12: TM 9-1425-381-10-8

Confidence or STD Par. 3-13 HLT OP

36 N o ass~gned d u t ~ e s THRU

3 8

39 Remove chocks and store in auxiliary equip- ment vehlcle.

CHAPTER 3

PROCEDURES FOR PERFORMING CONFIDENCE OR STANDARD COUNT

Section I. CONFIDENCE OR STANDARD COUNT

3- 13. Duties of HLT OP NOTE. Before making cable connections, remove caps

f rom connector and receptacle, and inspect electrical contacts. After connect~ng cable, mate connector cap wtth receptacle cap. After d~sconnecttng cable, install caps on connector and receptacle.

1 Drive auxiliary equ~pmen t vehtcle Into postt~on as directed by OST OP; set vehtcle brakes.

Page 13: TM 9-1425-381-10-8

Confidence or STD Par. 3-13

HLT OP

2 CAUTION: When removing equipment from container, do not discard rubber padding. This padding must be reused for storing the equip- ment.

Working w ~ t h OST OP, remove azimuth laying equipment f rom containers, remove60W44and four 60W43 cables, and place equipment on ground next to vehicle.

3 ( 1) Lay 60W44P2 to PTS tactical cable en- AND t ry panel and lay P I ends of two 6 0 W 4 3

4 cables to PTS commun~ca t~ons cable entry panel.

( 2 ) Connect two 6 0 W 4 3 cables to J 1 and J 4 on PTS communicat~ons cable entry panel.

5 ( 1 ) Assisted by OST OP, emplace HLT tent (f ig. 3 - 5 . 1 ) by performing ( 2 ) through (1 0 ) below.

NOTE. When emplacing HLT tent, in- sure that ST-120 prism wlndow and OST will be visible to HLT through tent windows.

( 2 ) Place tent on ground to allow the four adjustable poles to be installed in cor- ners of tent top.

( 3 ) Extend poles toapproximately 1.9 meters ( 6 . 3 feet), and Insert pole s p ~ k e s Into grommets in corners of tent top.

Page 14: TM 9-1425-381-10-8

Confidence or STD Par. 3 -13 HLT OP

NOTES I ,URN TENT i l D i W A I L BOilOM i l h P S iNS1DE 3iNi 2 PLACE i A N O B A G i OUii lOE OF lEN1 SiDE W h i i l ON TENT SIDE W A i l BOllOM

F i h P S ANL>ON GUT LINE i l A X i S Mi dB524

Figure 3 -5 .1 . Theodolite sunshield tent emplacement, typical.

( 4 ) Lay guy l ines parallel to each tent side, drive a stake approx~mately 1.8 meters ( 6 feet) f rom tent side in l ~ n e with each guy l ine.

NOTE. When tent is raised, poles must be in vertical pos i t~on.

(5) Grasp each pole and raise tent.

Page 15: TM 9-1425-381-10-8

Confidence or STD Par. 3-13

HLT OP

Attach guy llnes to stakes, and adjust guy llnes as necessary to properly sup- port tent. Secure tent slde walls topoles.

Turn tent slde wall bottom flaps inside tent, and drive stakes to secure tent sides to ground

Place sandbags as shown 1nf lgure3-5.1.

ZIP closed tent corners that are not used for access. Open wlndows as re- quired for azimuth laying.

Insure that tle straps will not interfere wrth zlppers In windows and access corner.

If dlrected by supervisor, asslst OST OP rn emplaclng OST tent ( (2 ) through ( 10) above) .

Obta~n a metal trlpod from posct~on next to auxiliary equipment veh~cle.

Position trrpod on ground (rn tent) a mlnlmum of 2 meters (6.6 feet) from guidance sect~on window, wrth semrfixed leg toward and directly In llne w ~ t h the w~ndow

Spread trlpod legs, and lock them in place by presslng down (as far as pos- slble) on trlpod spreader.

Loosen chuck on the semlflxed leg, and extend leg so that theodolite, when In- stalled on bed assembly, will be at a conven~ent height. Tighten chuck.

Page 16: TM 9-1425-381-10-8

Confidence or STD Par. 3-13 HLT OP

NOTE. Insure that chucks on adjust- able legs are adjusted loose enough to p e r m ~ t operation of handcranks, but not loose enough to allow tripod to wobble. While operating handcranks, suppor tup- per portion of t r ~ p o d so that adjustable legs can be extended and retracted without b ~ n d i n g .

( 5 ) Loosen chucks on adjustable legs, and level tr ipod by simultaneously operating handcranks unt i l b u b b l e In level is centered.

( 5 . 1 ) Place sandbag on tripod spreader, and check level.

( 6 ) Obtain bed assembly f rom position next to a u x ~ i ~ a r y equipment vehicle, position i t on tr ipod so that carriage thumbscrew IS facing away f rom semifixed leg, and secure it with t r ipod retainer assembly.

( 7 ) Loosen carriage thumbscrew, and move carrlage over one of the hand openings in bed assembly.

( 8 ) Obtain carrying case containing theodo- l i te f rom position next to auxlllary equip- ment vehicle, and place carrying case on a f ~ r m , level surface near tr ipod.

( 9 ) Grasp carrying strap just above the two clamps, and pul l i t in an outward direction, releasing clamps from base assembly. Lift hood from base assembly.

Page 17: TM 9-1425-381-10-8

Confidence or STD Par. 3-13

HLT OP

( 1 0 ) Loosen telescope clamp knob, and ro- tate telescope to hor~zonta l pos i t~on. T~gh ten clamp knob.

( 1 1 ) Loosen three lever nuts on base as- sembly, and slide levers away from base of theodolite.

CAUTION: When lifting theodolite, do not grasp large side of alidade (left- hand axle bearing). Failure to observe this caution will place undue pressure on collimation lever and make readjust- ment of collimation lever necessary.

( 1 2 ) Lift theodol~te f rom base assembly by grasplng small srde of al idade (r ight- hand axle bearing) with one hand, w h ~ l e steady~ng theodolite wrth other hand.

( 1 3 ) Posi t~on theodol~te, w ~ t h op t~ca l p l u m b ~ n g eyepiece toward operator, over mountrng hole In carriage, and secure theodolite with the mount ing screw. Move carrlage to center of bed, and t~gh ten thumb- screw

( 1 4 ) O b t a ~ n ALCB

( 1 5 ) Connect 6 0 W 4 4 P l to J 1 on the bottom of ALCB.

( 1 6 ) Obtarn headset f rom position next to aux i l~ary equ~pmen t vehicle, and connect headset to J 6 on bottom of ALCB.

Page 18: TM 9-1425-381-10-8

Confidence or STD Par. 3-13 HLT OP

( 1 7 ) Remove cover f rom ALCB, and install ALCB on tripod. Place cover in an area where it w ~ l l be out of the way and can be recoversd easily.

( 1 8 ) Open theodolite horizontal circle i l lumi- nat ing mi r ror .

NOTE. For night operations, refer to chapter 7, section V .

7 ( 1 ) Sight telescope on center of ST- 1 2 0 AND pr ism window.

8 ( 2 ) Rotate telescope eyepiece unt i l reticle

is sharply def~ned.

( 3 ) Loosen carriage thumbscrew, and move carriage unt i l objective end of telescope is reflected in the pr ism. Tighten car- r iage thumbscrew.

( 4 ) Connect cable f rom autoreflector lens assembly to THEOD LAMP receptacle on ALCB.

NOTE. If leveling has been previously performed, adjust screws only as re- quired to achieve level condition.

( 5 ) Loosen horizontal clamp knob and turn three leveling screws fully counterclock- wise; then p e r f o r m fine l eve l i ng as follows:

( a ) Rotate alidade unti l axis of plate level is parallel to a l ine through any two of the three leveling screws.

Page 19: TM 9-1425-381-10-8

Confidence or STD Par. 3-13

HLT OP

( b ) Turn these two screws clockwise two complete turns.

( c ) Center bubb le jn level by ro ta t~ng these two levellng screws equally in opposite d~rec t ions .

( d ) Rotate alidade through 1 , 6 0 0 mils ( 9 0 ° ) , and center bubble In level by ro ta t~ng third leveling screw.

( e ) Repeat ( a ) , ( c ) , and ( d ) above until bubble comes to rest centered in ~ t s vlal in both of these posi t~ons.

( f ) Rotate alidade through 3 , 2 0 0 m i l s ( 1 8 0 " ) f rom its position in ( a ) above; bubble should remain centered in its vlal. If bubble comes to rest off center, adjust plate level as prescribed in T M 9. 1 4 3 0 - 3 8 1 - 1 4 .

( 6 ) Insure that HLT remalns level dur ing laying procedures, and repeat pos~t ion ing and leveling operations as required.

9 Omit ( 1 ) through ( 8 . 1 ) below ~f vertical laylng IS r equ~ red .

NOTE. When set t ing scales using hor i - zontal dr ive knob or az imuth screw, always approach set t ing by ro ta t ing knob or screw In clockwise direct ion. I f se t t ing is passed, ro ta te knob or screw counterclockwise t o pass set t ing in opposi te direct ion, and then ro ta te knob or screw clockwise t o approach proper se t t ing .

Page 20: TM 9-1425-381-10-8

Confidence or STD Par. 3-13 HLT OP

( 1) Loosen telescope and horizontal c lamp knobs, and rotate HLT u n t ~ l OST tele- scope can be seen through HLT tele- scope. T~gh ten the clamp knobs.

( 2 ) Rotate azimuth screw unt i l vertical ret i - cle l ines are alined on center of auto- ref lect~on lens assembly housing of OST. Adjust telescope eyepiece as required.

( 3 ) Adjust telescope focusingtubeon theodo. l i te unt i l autoreflector of OST is sharply defined.

( 4 ) Rotate alt i tude and azimuth screws unt i l autoreflector is centered on single ver- tical reticle h e , and edges of autoreflec- tor co inc~de with intersections of double vertical reticle lines and horizontal reti- cle line.

( 5 ) Allow OST OP to a l ~ n e his instrument on autoreflector of HLT.

( 6 ) Repeat ( 4 ) and ( 5 ) above unti l auto- reflector remains properly centered in reticles of both theodolites.

( 7 ) Adjust focus of microscope eyepiece. Verify that inverter knob is set to hor i - zontal.

( 8 ) Rotate HLT micrometer knob to the decimal value on micrometer circle scale, and rotate horizontal dr ive knob for coincidence on horizontal circle scale at value announced by OST OP. Close horizontal circle drive cover.

Page 21: TM 9-1425-381-10-8

Confidence or STD Par. 3 - 1 3

HLT OP

( 8 . 1 ) Request OIC to ve r~ f y horlzontal scale read~ng .

( 9 ) Record FA as announced by PTS OP.

1 0 O m ~ t t h ~ s sequence rf vertical laylng is required. THRU

17 ( 1 ) Rotate micrometer knob to decimalvalue of FA.

( 2 ) Loosen HLT telescope and horizontal clamp knobs, rotate telescope to acqulre ST-120 prlsm, and then t~gh ten the clamp knobs.

( 3 ) V e r ~ f y that m~crometer circle scale 1s set correctly, arid rotate azimuth screw u n t ~ l horlzontal clrcle scale ind~cates recorded value of FA.

( 4 ) If ST. 1 2 0 pr lsm cannot be seen through telescope, repeat sequences 7 and 8 ( 3 ) through ( 5 ) above, sequence 9 (1) through ( 8 ) above (reciprocal coll ima- t ~ o n w ~ t h the OST), and (1) through ( 3 ) above, Repeat the operation, if required, unt i l the pr lsm can be seen.

1 8 Perform t h ~ s sequence only ~f ve r t~ca l laying is r e q u ~ r e d .

( 1 ) Loosen telescope and hor~zonta l c lamp knobs and carrlage thumbscrew.

( 2 ) Translate and rotate HLT as r e q u ~ r e d to center autoreflector In reticle; t ighten carrlage thumbscrew.

NOTE. If leveling has been previously performed, adjust screws only as re- q u ~ r e d to ach~eve level condit ion.

3 - 9

Page 22: TM 9-1425-381-10-8

Confidence or STD Par. 3-13 HLT OP

( 3 ) Loosen horizontal clamp knob and turn three leveling screws fully counterclock- wise, then perform fine leveling as follows:

( a ) Rotate alidade unti l axis of plate level is parallel to a l ine through any two of the three leveling screws.

( b ) Turn these two screws clockwise two complete turns.

( c ) Center bubble in level by ro- tating these two leveltng screws equally in opposlte directions.

( d ) Rotatealldade through 1 ,600 mils ( 9 0 ° ) , and center bubble ~n level by rotating th i rd leveling screw.

( e ) Repeat ( a ) , ( c ) , and ( d ) above unti l bubble comes to rest centered in its vial in both of these positions.

( f ) Rotate alidade through 3 ,200 mils ( 1 8 0 " ) f rom its position in ( a ) above, bubble should remain centered in ~ t s vial. If bubble comes to rest off center, adjust plate level as prescribed in T M 9- 1 4 3 0 - 3 8 1 - 1 4

( 4 ) Rotate HLT to view ST-120 and verify that autoreflector is centered in reticle. If autoreflector is not centered, loosen carriage thumbscrew and repeat ( 2 ) a n d (3 ) above and this step unt i l autore- flector remains centered.

Page 23: TM 9-1425-381-10-8

Confidence or STD Par. 3-13

H LT OP

Reciprocally collimate HLT with OST and set HLT scale (seq 9 ( 1 ) through ( 8 . 1 ) above).

Rotate HLT to view ST-120 ; trghten telescope and horizontal c lamp knobs.

Rotate azimuth and alt i tude screws unt i l autocollimation is achieved.

Request OIC to verify HLT horrzontal scale reading.

NOTE. Omit for vertical l ay~ng .

When LAY PLATF ~nd ica tor on ALCB lights, set and hold PLATF CONTROL swrtch to appropr late L or R posrtion u n t ~ l reflected image of autoreflector can b e seen In HLT telescope.

NOTE. If autoreflector cannot be seen because pr ism is no longer visible in telescope, translate HLT and proceed to sequences 7 through 17 above.

Adjust telescope focusing tube unt i l auto- reflector IS sharply defined In reticle.

Set and hold PLATF CONTROL sw~ tch to appropriate L or R pos i t~on u n t ~ l autoreflector is approximately centered In re t~c le .

NOTE if faster ST 120 ro ta t~ona l rate is required, press RESET switch to ob- tain fast slew rate, LAY PLATF indtcator lights for 5 seconds and then starts flashing, i nd~ca t i ng return to f ine slew rate Repeat (3 ) above

Page 24: TM 9-1425-381-10-8

Confidence or STD Par. 3-13 HLT OP

20 Omit (1) through ( 6 ) below if vertical laying is required and perform ( 7 ) through (10) below.

( 1 ) When LAY PLATF indicator f lashes, se t and hold PLATF CONTROL switch t o appropr iate L or R posi t ion and ro ta te HLT a l t i tude screw unt i l au toco l l imat ion is achieved (autore f - lector is centered on single vert ical re t ic le l ine, and edges o f autore- f lec tor coincide wi th intersect ions o f double vert ical ret ic le l ines and hor- i zonta l ret ic le l ine). I f a faster ST-120 ro ta t iona l speed is required t o achieve autoco l l i r~ ia t ion , press RESET switch; when LAY PLATF indicator l igh ts , proceed to sequence 1 9 (3) above.

( 2 ) When satisfied that autoreflector w ~ l l remain in alinement without fur ther ad- justment, notify supervisor that MONI- TOR switch can be pressed.

( 2 . 1 ) Request OIC to verify autocollimation and hor~zonta l scale setting to FA

NOTE. When MONITOR swrtch is pressed (MONITOR indicator lrghts and LAY PLATF indicator goes out) , the 6 0 - second op t~ca l monitoring period IS inl- tiated. Dur ing this t ime, theautoreflector is lighted for 55 seconds and then flashes for 5 seconds.

Page 25: TM 9-1425-381-10-8

Confidence or STD Par. 3-13

HLT OP

NOTE Angular displacement (dr i f t ) of ST 120 may be estimated by using the lateral distance between the double ver tical reticle lines as a reference The angle represented by this distance is approximately 0 2 mil

(3) When directed by supervisor, press MONITOR switch, and mon~tor ST 1 2 0 to determine if ~ t s dr i f t rate IS within

0 1 mil in 6 0 seconds (vertex of auto reflector remained within double vertical reticle lines), if ST 120 drift rate is out of tolerance, notify supervisor

NOTE After monitorcng period ends, approximately 9 0 seconds w ~ l l elapse before LAY PLATF Indicator starts flash ing, period~cally observe autoreflector to determcne that drift does not exceed 0 2 mil outside of either double vertical reticle line during this time (If RESET switch has been pressed, or during horizontal lay recycle, LAY PLATF in d~cator starts flashing wcthout delay at end of optical monitorrng period )

( 4 ) When LAY PLATF Indicator flashes, ~f ST 120 drift rate was out of tolerance dur~ngoptical monitoring period,orauto reflector IS now displaced more than 0 2 mil outside of e~ther double vertical reticle line, not~fy supervisor, press RE SET switch, and proceed to (1) above, if ST 120 drift is within tolerance, notify supervisor that COMPLETE switch can be pressed

3-13

Page 26: TM 9-1425-381-10-8

Confidence or STD Par. 3-13 HLT OP

NOTE If directed by supervisor, again monitor ST 1 2 0 to determrne if its drrft rate is within 0 1 mi l in 6 0 seconds If dr i f t rate is out of tolerance, notify supervisor, press RESET switch, and proceed to (1) above, if d r i f t is within tolerance, notify supervisor that COM PLETE switch can be pressed

( 5 ) When directed by supervisor to press COMPLETE switch, center autoreflector in re t~c le , if necessary, by setting and hoidrng PLATF CONTROL switch, then press COMPLETE switch

( 6 ) Notify supervisor that COMPLETE switch has been pressed

NOTE Omit ( 7 ) through ( 9 ) below if vertical laying is not required

( 7 ) When LAY PLATF indicatorflashes, press MONITOR switch, and monitor ST 1 2 0 to determine if its dr i f t rate is within 0 1 mi l in 6 0 seconds

( 7 1 ) When LAY PLATF indicator flashes, if ST 1 2 0 dr i f t is out of tolerance, notify supervisor, press RESET switch, and proceed to ( 7 ) above, if ST 1 2 0 dr i f t is within tolerance, notify supervisor that COMPLETE switch can be pressed

( 8 ) When drrected by supe rv i so r , press COMPLETE switch

( 9 ) Read and announce HLT scale setting

( 1 0 ) Request OIC to verify HLT scale setting

3-1 4

Page 27: TM 9-1425-381-10-8

Confidence or STD Par. 3-13 HLT OP

For a conf~dence count, proceed to sequence 22 below. For a standard count, proceed to sequence 29 below. For change of target with verttcal laying, perfor in procedures ~n para- graph 7-13.

22 Place hood over theodolite.

A conf~dence count with WSS. ~f being performed, is complete at the end of thls sequence.

2 3 If an addlt lonal m~ss i l e IS to be confidence counted, perform sequences 24 through 26 below; otherwise, perform sequences 27 and 28 below

No assigned duties

( 1 ) Remove ALCB and 60W44 from HLT tent.

( 2 ) Ass fs ted by OST OP, move 60W43, ALCB, and 60W44 to next f i r lng po- sltlon.

2 6 To complete subsequent conf~dence counts, perform sequences 1 through 23 above.

2 7 Close HLT tent. AND 28

Page 28: TM 9-1425-381-10-8

Confidence or STD Par. 3-13 HLT OP

29 ( 1 ) U s ~ n g plastic cover f rom accessory case and without d~s tu rb ing telescope or ien- tation, place cover over theodolite

( 2 ) Close HLT tent access corner.

( 3 ) Evacuate area.

NOTE. Perform ( 4 ) through ( 9 ) be- low only if directed by supervisor to perform a horizontal lay recycle.

( 4 ) Reenter area.

( 5 ) Open HLT tent w~ndows used for viewing ST-120 and OST, and open access corner.

( 6 ) Remove plastic cover f rom theodolite; loosen horizontal c lamp knob and slowly ro ta te a l i d a d e through 6 , 4 0 0 m i l s ( 3 6 0 " ) to check level.

NOTE. If theodolite is not level, ftne- level theodolite (seq 7 ( 5 ) above), re- ciprocally coll imate HLT with OST (seq 9 above), and proceed to ( 7 ) below.

( 7 ) Sight HLT on ST-120 pr ism (seq 1 0 ( 1 ) through ( 3 ) above).

( 8 ) If necessary and when LAY PLATF in dicator is flashing, set and hold PLATF CONTROL switch to appropriate L or R position u n t ~ l autocol l imat~on isachieved.

( 9 ) Proceed to sequence 2 0 ( 2 ) above.

Page 29: TM 9-1425-381-10-8

Confidence or STD Par. 3-14

OST OP

3- 14. Duties of OST OP NOTE. Before making cable connections, remove caps

from connector and receptacle, and inspect electrical contacts After connecting cable, mate connector cap with receptacle cap After disconnect~ng cable, ~ns ta l l caps on connector and receptacle

1 Guide auxiliary equipment vehicle ~ n t o position; then chock wheels.

2 CAUTION: When removing equipment from container, do not discard rubber padding. This padding must be reused for storing the equip- ment. Working with HLT OP, remove azimuth laying equ~pmen t f rom containers, remove 6 0 W 4 4 and four 60W43 cables, and place equipment on ground next to vehicle.

3 Lay 60W44 to HLT pos i t~on, connect 60W43 to AND A l O J 1 of EL and lay to OST position. If OST

4 is emplaced more than 2 4 meters (79 feet) f rom EL, use an addit ional 60W43 cable.

5 ( 1 ) Assist HLT OP in e~nplacing HLT tent (f ig. 3 - 5 . 1 ) by performing ( 2 ) through ( 10) below.

NOTE. When emplaclng HLT tent, in- sure that ST- 1 2 0 pr ism window and OST will be v i s i b l e to HLT t h r o u g h t e n t w~ndows.

Page 30: TM 9-1425-381-10-8

Confidence or STD Par, 3-14 OST OP

Place tent on ground to allow the four a d j u s t a b l e poles to be installed in corners of tent top.

Extend poles toapproxrmatety 1.9 meters ( 6 . 3 feet), and insert pole spikes rnto grommets in corners of tent top.

Lay guy l ines parallel to each tent srde; dr ive a stake approximately 1 .8 meters ( 6 feet) f rom tent stde in l ine with each guy Ii i ie.

NOTE. When tent IS raised, poles must be in vertical positton.

Grasp each pole and raise tent

Attach guy l ines to stakes, and adjust guy lines as necessary to properly sup- port tent. Secure tent side walls to poles.

Turn tent side wall bottom flaps tnsrde tent, and dr ive stakes to secure tent sides to ground.

Place sandbags as shown i n f i gu re3 -5 .1 .

Zip clcsed tent corners that a re not used for access. Open windows as re- quired for azrmuth laying.

Insure that tre straps wil l not interfere wrth zippers in windows and access corner.

I f directed by supervisor, and assisted by HLT OP, emp lace OST tent ( ( 2 ) through ( 1 0 ) above); otherwise, set u p umbrella for OST.

Page 31: TM 9-1425-381-10-8

Confidence or STD Par. 3-14

OST OP

Obtain a wooden tripod, carry ing case conta~n ing target sets, and battery box from pos i t~on next to auxiliary equipment vehicle, and position equipment a t OL station marker

Loosen wingnuts on tr ipod legs, and extend legs. T~gh ten w~ngnuts .

Unbuckle straps, spread t r ~ p o d legs, and set trtpod on ground directly over

station marker on OL, and adjust t r ~ p o d legs unt i l top of t r ~ p o d is at a conven~ent height.

Push ends of tr ipod legs into ground, using foot pressure, so that top of tr ipod is approximately level

Remove tr ipod head cover, and install i t on f ixing plate on t r ~ p o d leg

Hook battery box on bracket on tripod,

Remove a t r ibrach from the carry ing case, and loosely secure it on t r ~ p o d with br idge screw.

Rotate optical p lumbing eyeplece unt i l crosslines and /o r clrcle IS in focus.

Remove a target and a night l ight at- tachment f rom carrylng case, and attach night light to target

Install target on tr ibrach.

Turn the three leveling screws on tr l - brach fully counterclockwise.

B r ~ n g c~ rcu la r level on tr ibrach to rough center by adjust ing tr ipod legs.

3-19

Page 32: TM 9-1425-381-10-8

Confidence or STD Par. 3-14 OST OP

( 1 3 ) Carefully move tribrach on tripod head untri crossiines and/or c ~ r c l e of optical p lumbing eyepiece reticle is centered over station marker.

NOTE. For night operations, refer to chapter 7 , section V .

( 1 4 ) Secure t r~b rach to tr ipod by t~ghten ing bridge screw.

NOTE. If leveling has been previously performed, adjust screws only as re- quired to achieve level cond i t~on.

( 1 5 ) Loosen horizontal clamp knob and turn th ree Jeveling screws fully counterclock- wise, then p e r f o r m fine leve l ing as follows:

( a ) Rotate a l ~ d a d e unti l a x 6 of plate level IS parallel to a l ine through any two of the three leveling screws.

( b ) Turn these two screws clockwise two complete turns.

( c ) Center bubble in level by rotating these two leveling screws equally ~n opposite directions.

( d ) Rotate a l~dade th rough 1 , 6 0 0 mils ( 9 0 ° ) , and center bubble in level by ro ta t~ng third leveling screw.

( e ) Repeat ( a ) , ( c ) , and ( d ) above untrl bubble comes to rest centered ~n its v ~ a l in both of these positions.

Page 33: TM 9-1425-381-10-8

Confidence or STD Par. 3-14

OST OP

( f ) Rotate a l i d a d e through 3 , 2 0 0 mi ls ( 1 8 0 " ) f rom its position In ( a ) above, bubble should remain centered in its vial I f bubble comes to rest off center, adjust plate level as prescribed in TM 9 1 4 3 0 3 8 1 1 4

( 1 6 ) Verify that crosslrnes and/or crrcle of optical p lumbing eyepiece has remained alined with center of station marker if they have not remained alined, loosen bridge screw, and repeat ( 1 3 ) through ( 1 5 ) above

( 1 7 ) Rotate target untrl face of pattern is perpendicular to OL ( facing OST).

NOTE. For night operation, or dur ing daylight hours when condit ions requtre that target be i l luminated, perform pro- cedures in ( 1 8 ) below

CAUTION: When illumination is not needed, rotate variable resistor on bat- tery box fully counterclockwise.

( 1 8 ) Connect nrght light attachment cable to variable output ( le f t ) receptacle on bot- tom of battery box.

( 1 9 ) Repeat levellng, ( 1 5 ) and ( 1 6 ) above, as required to maintarn level of target.

( 2 0 ) Request OIC to verify OLT optical p lumb and level.

Page 34: TM 9-1425-381-10-8

Confidence or ST0 Par. 3-14 OST OP

Obtain a wooden tripod and battery box from position next to aux~ l ia ry equip- ment veh~cle, and position tr ipod at OST pos~t ion (in tent, if app l~cab le) .

Loosen wingnuts on tripod legs, and extend legs. Tighten w~ngnuts .

Unbuckle strap, spread tripod legs, and set t r ~ p o d on ground, directly over OL station marker .

Adjust tr ipod legs unt i l top of tr ipod IS

at a convenient height. Make allowance for p u s h ~ n g ends of t r ~ p o d legs into ground

Push ends of t r ~ p o d legs into ground, u s ~ n g foot pressure, so that top of t r ipod rs approximately level.

Remove t r ~ p o d head cover, and install i t on f i x ~ n g plate on tr ipod leg.

Hook battery box on bracket on tripod.

Obtain carry ing case contaming theodo l i te f rom pos i t~on next to auxiliary equip mentveh~c le , and place carrying case on a f irm, level surface near tr ipod

Grasp carry ing strap just above the two clamps, and pul l i t in an outward direc- tion, releasing clamps from base assem- bly. Lift hood from base asse117bly.

Loosen telescope clamp knob, and rotate telescope to hor~zonta l pos~t ion . T~ghten clamp knob.

Page 35: TM 9-1425-381-10-8

Confidence or STD Par. 3-14

OST OP

( 1 1 ) Loosen three lever nuts on base as- sembly and slide levers away from base of theodolite.

CAUTION: When lifting theodolite, do not grasp large side of alidade (left- hand axle bearing). Failure to observe this caution will place undue pressure on collimation lever and make readjust- ment of collimation lever necessary.

( 1 2 ) Lift theodol~te from base assembly by grasping small s ~ d e of alrdade (right hand axle bearrng) with one hand, while steadying theodolite w ~ t h other hand

( 13) Place theodolrte on tripod, and loosely secure it to trlpod by means of bridge screw

NOTE. For night operation, refer to chapter 7, sect~on V .

( 1 4 ) Rotate optical plumbing eyepiece until crosslrnes and/or circle rs in focus.

( 1 5 ) Turn the three leveling screws on trc- brach fully counterclockwise.

( 16 ) Bring circular level on theodolite to rough center by adjusting trlpod legs.

( 17 ) Carefully move theodolite on tripod head until crosslines and/or circle of optrcal plumbing eyeplece retlcle IS centered over station marker.

( 1 8 ) Secure theodol~te to tripod h\l tightening bridge screw.

3-23

Page 36: TM 9-1425-381-10-8

Confidence or ST0 Par. 3-14 OST OP

NOTE. If leveling has been previously performed, adjust screws only as re- quired to achieve level cond i t~on.

( 19 ) Loosen horizontal clamp knob and turn three leveling screws fully counterclock- wise, then perform fine l e v e l ~ n g as follows:

( a ) Rotate alidade unti l axis of piate level is parallel to a line through any two of the three leveling screws.

( b ) Turn these two screws clockw~se two complete turns.

( c ) Center bubble in level by rotating these two leveling screws equally in opposite directions.

( d ) Rotate aiidade through 1 , 6 0 0 mi ls ( 9 0 ° ) , and center bubble in level by rotating th i rd leveling screw.

( e ) Repeat ( a ) , ( c ) , and ( d ) above unt i l bubble comes to rest centered in its vial in both of these positions,

( f ) Rota te alidade through 3 , 2 0 0 mi ls ( 1 8 0 " ) f rom its position in ( a ) above, bubble should remain centered in its vial I f bubble comes to rest off center, adjust plate level as prescribed in TM 9 1 4 3 0 3 8 1 1 4

( 2 0 ) Verify that crosslines and/or circle of opt~cal p l u m b ~ n g eyepiece has remalned on center of station marker. I f necessary, loosen b r ~ d g e screw, and repeat ( 1 7 ) through ( 1 9 ) above.

Page 37: TM 9-1425-381-10-8

Confidence or STD Par. 3-14

OST OP

( 2 0 . 1 ) Request OIC to verify OST opt~ca l p lumb and level.

( 2 1 ) Obtain a headset-microphone assembly from position next to auxiliary equip. ment veh ic le . Connect headse t t o 60W43P2 .

CAUTION: When battery box is not in use, rotate variable resistor fully counterclockwise.

( 2 2 ) Connect autoreflection lens assembly cable to variable output ( lef t ) receptacle on bottom of battery box.

( 2 3 ) Open theodolite horizontal circle i l lumi- n a t ~ n g mi r ror .

8 ( 1 ) Loosen OST telescope and horizontal clamp knobs, and p o ~ n t telescope at OLT. Tighten clamp knobs.

( 2 ) Adjust telescope eyepiece unti l reticle crossl~nes a re ~n focus

( 3 ) Adjust telescope focusing tube u n t ~ l OLT is In focus

NOTE. When set t ing scales using hor izonta l dr ive knob or az imuth screw, always approach set t ing by ro ta t ing knob or screw in clockwise direct ion. I f se t t ing is passed, ro ta te knob or screw counterclockwise to pass set t ing in opposi te direct ion, and then ro ta te knob or screw clockwise t o approach proper set t ing.

3-25

Page 38: TM 9-1425-381-10-8

Confidence or STD Par. 3-14 OST OP

( 4 ) Rotate azimuth screw unti l rettcle cross- lines are centered on OLT.

( 5 ) Obtain and enter azimuth value of OL on l ine 1 of computation form (ftg. 3-6), and compute value for ltne 5 (init ial scale setting of OST).

( 6 ) Adjust focusing of mtcroscope eyepiece. Vertfy that inverter knob is set for hori- zontal.

( 7 ) Rotate micrometer knobfordec in~aIva lue on micrometer ctrcle scale, and rotate hor~zonta l dr ive knob for coincidence on horizontal circle scale a t value recorded on l ~ n e 5 of computa t~on form Close c ~ r c l e dr lve cover, and verify setting.

( 8 ) Request OIC to ve r~ f y alinement wtth OLT and scale setting.

9 Omit (1) through ( 8 ) below tf vertical l a y ~ n g IS required.

( 1) Loosen OST telescope and horizontal clamp knobs, and point telescope at HLT. Tighten clamp knobs.

( 2 ) Rotate a z ~ m u t h screw unt i l vertical reti- cle crossltne IS al lned on center of HLT autoreflection lens assembly housing.

( 3 ) Adjust OST telescope focusing tube unt i l HLT autoreflector is sharply def~ned.

( 4 ) Allow HLT OP to allne on OST auto- reflector.

Page 39: TM 9-1425-381-10-8

Confidence or STD Par. 3-14

OST OP

( 5 ) Rotate azimuth and alt i tude screws unt i l HLT autoreflector is centered on s ~ n g l e vertical r e t ~ c l e line, and edges of auto- reflector c o ~ n c ~ d e w ~ t h the ~ntersect ions of the double vertical reticle lines and horizontal reticle l ~ n e

( 6 ) Repeat ( 4 ) and ( 5 ) above u n t ~ l auto- reflector remains properly centered in telescope of both theodol~tes.

( 7 ) Request OIC to verify alinelnent w ~ t h HLT and reverse horizontal scale reading.

( 8 ) Announce reverse ho r i zon ta l sca le set t~ng, and record value on l ine 6 of computation fo rm.

( 9 ) Record announced FA on l ine 8 of com- pu ta t~on form.

10 Omit this sequence if ver t~ca l laying ~ s r e q u i r e d . THRU

17 ( 1 ) Loosen OST telescope and horizontal clamp knobs, and point telescope at OLT Tighten clamp knobs.

( 2 ) Rotate telescope focus~ng tube unt i l OLT I S In focus.

( 3 ) Rotate azimuth screw unt i l r e t ~ c l e cross- lines are centered on OLT.

( 4 ) Read OST scale and complete lines 1 0 through 1 2 on computation form. If l ~ n e 1 2 on computation fo rm IS greater than 0 . 0 2 5 mi l , rotate rn~crometer and hor l - zontal dr lve knobs as necessary to set the scales, and repeat sequence 9 (1) through ( 8 ) above.

Page 40: TM 9-1425-381-10-8

Confidence or STD Par. 3-14 OST OP

(5) Verify that OST has remalned level and that crosslines and/or circle of optlcal p lumbing eyepiece has remained on cen ter of statron marker

( 6 ) Request OIC to verify OST horizontal scale setting and optlcal p lumb.

18 Perform thls sequence only if verttcal l ay~ng ts required.

( 1 ) Reciprocally collimate OST wrth HLT, and record and announce HLT scale setting (seq 9 above).

( 2 ) Allne OST on OLT, and verrfy OST scale se t t~ng (seq 10 above).

19 Recrprocally collimate OST with HLT as re- qu l red (seq 9 t h r o u g h 17 above); for a standard count, place hood over theodolite and close OST tent, if applicable.

20 Omrt (1) below if vertical layrng IS requrred, and perform (2) below.

( 1 ) After HLT OP presses MONITOR switch on ALCB, close HLT tent wlndow used for vlewlng OST.

NOTE. Omit ( 2 ) below tf vertical laying IS not reauired.

( 2 ) Record HLT scale setttng announced by HLT OP on lme 7 of computat~on form, and then compute value and d i rec t~on of missrle rotatron.

( 3 ) Request OIC to verlfy computations. 3-28

Page 41: TM 9-1425-381-10-8

Confidence or STD Par. 3-14

OST OP

2 1 For a confidence count, proceed to sequence 2 2 below. For a standard count, proceed to sequence 2 9 below. For change of target wlth ver t~ca l laying, perform procedures ~n para- graph 7 .14.

22 Place hood over theodol~te

A confidence count w ~ t h WSS, ~f b e ~ n g performed, IS

complete at the end of th is sequence

2 3 If an add~t iona l m~ss i le is to be confidence counted, perform sequences 2 4 through 2 6 below, otherwise, perform sequences 2 7 and 2 8 below

24 No ass~gned duties.

25 ( 1 ) Close HLT tent

( 2 ) Assist HLT OP In moving 60W43 , ALCB, and 60W44 to next f ~ r i n g positlon

26 To complete subsequent confidence counts, perform sequences 1 through 2 3 above.

27 No asslgned dut ies AND 2 8

29 ( 1 ) After HLT OP presses COMPLETE switch on ALCB, close HLT tent wlndow used for vievving ST- 1 2 0 .

( 2 ) Evacuatearea.

Page 42: TM 9-1425-381-10-8

Confidence or STD Par. 3-14 OST OP

NOTE. Perform ( 3 ) through ( 1 2 ) be- low only if directed by supervisor to perform a hor~zonta l lay recycle.

( 3 ) Reenter area

( 4 ) Remove hood f rom OST; loosen hori- zontal clamp knob and slo\vly rotate alidade through 6 , 4 0 0 mils ( 3 6 0 ° ) to check level.

NOTE. If theodolite is not level, f ine- level theodolite (seq 7 (19) and ( 2 0 ) above). Request OIC to verify level.

( 5 ) Loosen OST telescope and horizontal clamp knobs, and point telescope at OLT. Tighten clamp knobs.

( 6 ) Adjust telescope eyepiece unti l r e t~c le crosslines a r e in focus.

( 7 ) Adjust telescope focusing tube unt i l OLT is in focus.

Page 43: TM 9-1425-381-10-8

Confidence or STD Par. 3-14

OST OP

( 8 ) Rotate azimuth screw unti l retlcle cross- l ~ n e s are centered on OLT.

( 9 ) Adjust focuslng of microscope eyepiece. Verify that inverter knob is set for hor i - zontal.

( 1 0 ) Rotate microtneter knob for decimalvalue on micrometer circle scale, and rotate horizontal dr lve knob for coinc~dence on hor~zonta l circle scale at value recorded on l lne 5 of computation form. Close c ~ r c l e dr ive cover, and request OIC to verify scale settlng.

( 1 0 . 1 ) Reciprocally collimate OST with HLT as r e q u ~ r e d (seq 9 and 10 above).

( 11) Place hood over OST and close tent, if applicable.

( 1 2 ) Proceed to sequence 20 above.

Page 44: TM 9-1425-381-10-8

Confidence or STD Par. 3-14 OST OP

! Attm",t, do, 2 ii I,"*, , , i r , , li,"" ,600 "<id 0 l 0 0 " i h ~ . ~ ' .

3 (Ic"ra, llnr I

1 Suliliurl ,600 #,an3 roliir a, 4.r 3

5 , c o , ~ ..,lo"# S, OSi on OLi

6 W L I linli %ellinn t o O i l # r r s h r "I1 ~~ ,>d ln i j lo fill / $ l

2nd

3rd

I H l i . ~ a d m g l o i i#,srn

8 ia rgohmulh +it1 "I' . r n b ~ , , ~ < ~ , l"i 1-4

P Drlrtrd

C o M r i i i i THE P O L L O W ~ N G TO V E R I ~ Y oii icni i i i i r i n G

I 0 Ll, le iorOS1,rad.ny tooti x.,rhprr, i r g i iu ,o i

I I O l l .r.i,iiny 3" "kt 0, , .r 5 rhlri,e"r, 5 % lh'

! 2 sub ,,,> ', I ,,,* I ! C s m m ,,"* lo t* , ,>*",'k 'a""? ,, r"s"tt ss

gieoiei lnan 0 05 'o, o l l o s i , r r outsil I , "suit is I l r o i r

ahan 0 021 l r ~ e n l laslrs I and 6

Ind

Bbd -- COMPLETE THE IOLIOW1NG O N i i l i " ( 1 IRANILITION i i YiOliiRiD

,"in N i A or " < I ,wo*.,>s lap. ,m, xhvhr .e l IIY""1e' - 28 Y L I seading I o y l l , m n r i A N i A r h ~ i l e r r 8 c$ I n s

21 I ~ h l , " ' , ilnr 2 o i r o m ilnr i s

22 U" i,,., "i.,ir*l h " 0 b XO b r 21 ilonliatian d.rlnnir " y i t -- . N"," t i V L l ..ndng L a I,rim , i r . r , hum, i l l i i A tuua i lo l i k i l t i V L I

,..d,,,y l a v,,im ,. y.rot-. ,ti",, i A N i l *."rnl"li l i * l i l

-

Figure 3-6. Azimuth laying computation and recording form.

Page 45: TM 9-1425-381-10-8

Quick Par. 4-10

HLT OP

CHAPTER 4

QUICK COUNT

4-10. Duties of HLT OP

NOTE Befo re rnaking cab le connect ions, remove caps f rotn connector a n d receptac le, a n d Inspect e l e c t r ~ c a l contacts Af ter connect ing cable, m a t e connector c a p wit11 receptac le c a p Af ter d i s c o n n e c t ~ n g cable, insta l l caps o n connector and receptac le

1 ( i ) Open H L T tent w indows fo r v iewlng OST a n d ST 120. a n d open access c o r n e r

(1.1) Remove hood f rom theodol i te

( 2 ) Rotate te lescope eyepiece un t i l re t ic le is sharp ly d e f ~ n e d

( 3 ) S low ly r o t a t e a l idade t h r o u g h 6 , 4 0 0 m i l s (360" ) t o d e t e r m i n e ~f t h e o - d o l ~ t e i s leve l ( b u b b l e remarns c e n - t e r e d w ~ t h i n 2 g r a d u a t r o n s rn p l a t e l e v e l ) , i f t heodo l r te I S l e v e l , p r o c e e d t o ( 5 ) b e l o w , i f t h e o d o l i t e 1s n o t leve l , p r o c e e d w i t h ( 4 ) be low

NOTE I f level ing has been p rev~ous ly per formed, adjust screws only as required t o achieve level condi t ion

( 4 ) Loosen h o r ~ z o n t a l c l a m p k n o b a n d t u r n t h r e e level ing screws fu l ly coun te rc lock - wise, then p e r f o r m f i n e level ing as io l lows.

4-1

Page 46: TM 9-1425-381-10-8

Quick Par. 4-10 HLT OP

( a ) Rotate alidade unti l axis of plate level is parallel to a line through any two of the three leveling screws.

( b ) Turn these two screws clockwise two complete turns.

( c ) Center bubble in level by rotating these two leveling screws equally in opposite directions

( d ) Rotate a l ~ d a d e through 1 , 6 0 0 mils ( 9 0 ° ) , and center bubble in level by rotating th i rd leveling screw

( e j Repeat ( a ) . ( c ) , and ( d ) above unti l bubble comes to rest centered in its vial in bcth of these positions

( f ) Rotate alidade through 3 , 2 0 0 mils ( 1 8 0 " ) f rom its pos i t~on in (a) above, bubble should remain centered in its vial If bubble comes to rest off center, adjust plate level as prescribed in TM 9 1 4 3 0 3 8 1 14

( 5 ) Insure t ha t HLT rernatns level wi th in 2 graduat ions dur ing laying proc- edures and repeat pos i t i on~ng and level ing operat ions as required.

(6) Request OIC to verify HLT level. NOTE. If HLT was releveled, request

OST OP to reciprocally collimate HLT with OST; perform ( 7 ) through (15) below.

( 7 ) Loosen telescope and horizontal clamp knobs, and rotate HLT unti l OST tele- scope can be seen through HLT tele- scope. Tighten clamp knobs.

Page 47: TM 9-1425-381-10-8

Quick Par. 4-10

HLT OP

NOTE When se t t ing scales us ing hor izonta l drive knob or a z ~ m u t h screw always approach set t ing by ro ta t ing knob or screw In clockwise d i r e c t ~ o n I f set t ing i s passed, ro ta te knob or screw counter clockwise t o pass s e t t ~ n g In o p p o s ~ t e d ~ r e c t i o n , and then ro ta te knob or screw clockwise t o approach proper se t t i ng

(8) Rotate a z ~ m u t h screw u n t ~ l ver t ica l re t icle l ines are a l ~ n e d on center o f autore f lect ion lens assembly housing of OST Adjust te lescope eyeplece as required

(9) Adjust telescope f o c u s ~ n g tube on t h e t h e o d o l ~ t e tint11 autoref lector of OST is sharply d e f ~ n e d

( 1 0 ) Rotate a l t i tude and a z ~ m u t h screws u n t ~ l autoref lector IS centered on s ~ n g l e ver t i ca l ret ic le l ine, and edges o f autore f lector coincide w ~ t h in tersect ions o f double ver t ica l ret ic le l ines and hori zontal ret ic le l ine

( 1 1 ) Al low OST OP t o al ine his inst rument on autoref lector o f HLT

( 1 2 ) Repeat ( 1 0 ) and ( 1 1 ) above un t i l autore- f lector remalns proper ly centered in r e t - icles o f both theodol i tes

( 1 3 ) Adjust focus of microscope eyepiece Verify tha t inver ter knob is set to hor l - zontal

( 1 4 ) Rotate HLT micrometer knob t o t h e d e c ~ m a l value on micrometer circle scale, and ro ta te hor izonta l d r ~ v e knob fo r coin- cidence on hor izonta l circle scale at value

Page 48: TM 9-1425-381-10-8

Quick Par. 4-10 HLT OP

announced by OST OP Close hor izonta l circle drive cover, and request OIC t o ver i fy hor izonta l scale se t t i ng

( 1 5 ) Verify FA as announced by PTS OP

2 ( 1 ) Rotate m ic romete r k n o b t o dec ima lva lue THRU of FA ( l i n e 8 o n appl icable az imuth

5 lay ing computa t ion f o r m )

( 2 ) Loose11 H L T te lescope and hor i zon ta l c l a m p knobs , a n d ro ta te te lescope t o acq i i i re S T 1 2 0 p r i sm; then t ighten c l a m p knobs

( 3 ) Ver i fy that in icro ineter c i r c le scale I S

set correct ly , a n d ro ta te a z ~ m u t h screw u n t ~ l hor izonta l c i r c le scale ind icates recorded value of FA

(4 ) Adjust telescope focusing tube un t i l autoref lector i s sharply def ined In ret ic le

NOTE I f a d iagnost ic t e s t has been per formed a f te r the missi le has been con f idence counted, the ST 1 2 0 wil l not automat ica l ly ro ta te t o the FA, proceed t o sequence 6 below

( 5 ) Observe S T 1 2 0 as i t automat ica l ly rotates t o FA and ro ta te HLT al t i tude screw t o achieve autocol l imat ion (autore f lector 1s centered on single ver t ica l r e t icle l ine, and edges of autoref lector coin cide wi th in tersect ions of double ver t ica l ret ic le l ines and hor izonta l ret ic le l ine)

Page 49: TM 9-1425-381-10-8

Quick Par. 4-10

HLT OP

6 ( 1 ) If r e q u i r e d , a n d when LAY PLATF i n d ica to r f lashes set a n d ho ld PLATF CONTROL s w ~ t c h to appropr ia te L o r R p o s ~ t i o n a n d ro ta te HLT a l t i t ude screw u n t ~ l au toco l l~ ina t ion is a c h ~ e v e d If a faster ST 1 2 0 r o t a t ~ o n a l speed is r e q u i r e d to dchleve au toco l l~mat ion p r o ceed t o (2) oelow, otherwise, p roceed to ( 3 ) below

( 2 ) Press RESET switch, set a n d ho ld PLATF CONTROL swi tch to a p p r o p r i a t e L o r R p o s ~ t i o n u n t i l autoref lector is approx i - mate ly cen te red in ret ic le , and p roceed t o ( 1 ) above

( 3 ) When sat is f ied t h a t autoref lector wil l re ma in In alrnement w ~ t h o u t fur ther ad- justment , request OIC t o ver i fy autocol I imat ion and horizontal scale set t ing t o FA

NOTE When MONITOR swi tch i s pressed (MONITOR i n d ~ c a t o r l ights and LAY PLATF indicator goes out) , the 10- second o p t ~ c a l rnon i to r~ng per iod is in - ~ t i a t e d D u r ~ n g th is t ime, the autore f lector i s l ~ g h t e d for 5 seconds and then f lashes for 5 seconds

Page 50: TM 9-1425-381-10-8

Quick Par. 4-10 HLT OP

NOTE. Angular displacement ( d r i f t ) o f ST-120 may be estimated by us lng the la te ra l d is tance between t h e double ver- t ~ c a l ret ic le l ines as a reference. The angle represented by th i s distance is ap- prox imate ly 0 .2 mi l .

( 4 ) Press MONITOR swltch, announce " M o n ~ t o r pressed," and moni tor ST-120 t o determlne i f ~ t s d r i f t ra te is wi th in 0 . 1 mil In 1 0 seconds (ver tex of autoref lector r e m a ~ n e d wi th in double ver t ica l ret ic le l ines), I f ST-120 d r i f t ra te i s out of to l - erance, notr fy supervisor.

( 5 ) W h e n LAY PLATF i n d i c a t o r f l a s h e s a n d i f S T - 1 2 0 d r i f t r a t e i s o u t o f t o l - e r a n c e , n o t i f y superv iso r , p ress RESET s w i t c h , a n d p r o c e e d t o ( 1 ) above ; i f S T - 1 2 0 d r i f t r a t e i s w i t h i n t o l e r a n c e , n o t i f y superv iso r t h a t COMPLETE s w i t c h c a n b e p r e s s e d .

NOTE. I f d ~ r e c t e d by supervisor, agaln m o n ~ t o r ST-120 t o determlne i f i t s d r i f t ra te is wl th in 0 . 1 m i l In 6 0 seconds. I f d r i f t ra te is ou t o f tolerance, no t l f y su- pervisor, press RESET s w ~ t c h , and pro- ceed t o (1) above; ~f d r i f t ra te IS w i th ln to lerance, no t i f y supervisor tha t COM- PLETE swrtch can be pressed.

( 6 ) When d i rected by supervisor t o press COMPLETE switch, center autoref lector In r e t ~ c l e , i f necessary, by se t t l ng and hold ing PLATF CONTROL s w ~ t c h ; then press COMPLETE swl tch

Page 51: TM 9-1425-381-10-8

Quick Par. 4-10 HLT OP

( 7 ) Notify supervisor that COMPLETE sw~ tch has been pressed.

( I ) Using plastic cover f rom accessory case, and without disturbing telescopeorrenta tion, place cover over theodolite

( 2 ) Close HLT tent access corner

( 3 ) Evacuate area

NOTE. Perform (4 ) through (7 ) below only ~f directed by supervisor to per fo rm a hor~zonta l lay recycle

( 4 ) Reenter area

( 5 ) Open HLT tent windows used for view- ing ST-120 and OST, and open access corner.

( 6 ) Remove plastic cover f rom theodolite; loosen hor~zonta l clamp knob and slowly rotate alidade through 6,400 mils ( 360 " ) to check level.

(7) If theodolite is level within 2 graduations, proceed to sequence 2 above. If theo- dolite 1s not level within 2 graduations, fine-level theodolite (seq l ( 4 ) above), re- c~procally collimate HLT with OST (seq l ( 7 ) through (15) above), then proceed to sequence 2 above.

If an additional missile is to be f~ red , begin sequence 8 below. I f evacuation is required, perform procedures in paragraph 5-10.

8 Return to f l r ~ n g position.

Page 52: TM 9-1425-381-10-8

Quick Par. 4-10 HLT OP

9 ( I ) Ass~st PTS OP In disconnect~ng cables f rom PTS tact~cal cabie entry panel

( 2 ) Install caps on al l connectors and piace cables out of path of PTS-PS vehicle.

10 ( 1 ) Assisted by OST OP, move 6 0 W 4 4 , 6 0 W 4 3 , and ALCB to next flrcng po sitton

( 2 ) Lay 6 0 W 4 3 and 6 0 W 4 4 to PTS

( 3 ) Connect 6 0 W 4 3 to PTS comrnunrcat~ons cable entry panel

( 4 ) lnstail ALCB on HLT t r ~ p o d

( 5 ) Assist EL OP in removlng 4 2 W 5 0 . 4 2 W 5 4 , and 6 0 W 1 0 1 from PTS PS vehlcle

( 6 ) Lay 4 2 W 5 0 , 4 2 W 5 4 , and 6 0 W 1 0 1 to EL

11 ( 1 ) Open HLT tent wrndows used for view- ing S T - 1 2 0 and OST, and open access corner.

(2) Remove hood from theodol~te.

12 Begln sequence 112) above AND 13

Page 53: TM 9-1425-381-10-8

Quick Par. 4- 11

OST OP

4- 1 1 . Duties of OST OP NOTE Before making cable connections, remove caps

f rom connector and receptacle, and inspect electrical contacts After connecting cable, inate connector cap with receptacle cap After disconnecting cable, install caps on connector and receptacle

1 ( 1 ) Verify emplacement of OLT as follows. THRU Verify that crosslines and/or c ~ r c l e of

4 optical p lumbing eyepiece has remained alined with center of station marker If they have not remained alined, loosen br idge screw, and carefully move t r i brach on tripod head unti l crosslines and/or c ~ r c l e of op t~ca l p lumbing eye piece reticle is centered over station marker Secure tr ibrach to t r ipod by tightening br idge screw, and proceed to ( 1 2 ) below

(1 .1) I f O L T I S out o f level by more than 2 graduat ions, proceed w ~ t h (1 .2) below; otherwise, proceed t o ( 2 ) below.

NOTE. If leveling has been prevrously performed, adjust screws only as required to ach~eve level condrtion.

( 1 2 ) Loosen horizontal c lamp knob and turn three leveling screws fully counterclock wise, then perform f ine leveling as follows:

4-9

Page 54: TM 9-1425-381-10-8

Quick Par. 4 -1 1 OST OP

( a ) Rotate alidade unti l axis of plate level is parallel to a line through any two of the three leve l~ng screws.

( b ) Turn these two screws clockwcse two complete turns.

( c ) Center bubble cn level by rotatcng these two levellng screws equally in opposcte directions.

( d ) Rotate alidade through 1 ,600 mi ls ( 9 0 ° ) , and center bubble in level by rotatcng third leve l~ng screw.

( e ) Repeat (a), (c ) , and ( d ) above u n t ~ l bubble comes to rest centered in its v ~ a l in both of these positcons.

( f ) Rotate alrdade through 3 , 2 0 0 mi ls ( 1 8 0 " ) f rom ~ t s position cn (a) above, bubble should remaln centered in its vial If bubble comes to rest off center, adjust plate level as prescribed ~n Tlj l 9 1 4 3 0 3 8 1 14

( 1 . 3 ) V e r ~ f y that target face pattern 1s per- pendicular to OL (facing OST).

( 2 ) Remove hood from theodolite.

( 3 ) Rotate optlcal p lumbing eyepiece unt11 reticle crossl~nes and/or circle (reticle) is ~n focus. Verlfy that reticle 1s centered on OL station marker, if reticle IS cen- tered over station marker, proceed to (4) below; if retlcle is not centered

Page 55: TM 9-1425-381-10-8

Quick Par. 4-1 1

OST OP

over station marker, loosen br ldgescrew and carefully move theodo l~ te on trlpod head untrl reticle is centered over sta- tion marker, t ighten br idge screw, and proceed to ( 5 ) below.

(4) Loosen horizontal clamp knob and slowly rotate alidade through 6,400 mils (360" ) to determine i f theodolite is level (bubble remains centered within 2 graduations in plate level); if theodolite is level, proceed to ( 7 ) below; i f theodolite is not level, proceed with (5 ) below.

NOTE. If leveling has been previously performed, adjust screws only as required t o achieve level condition.

( 5 ) Loosen horrzontal c lamp knob and turn three leveling screws fully counterclock- wise; then perform f lne levellng as follows:

( a ) Rotate alidade vnt l l axls of plate level IS parallel to a l lne through any two of the three leveling screws.

( b ) Turn these two screws clockwise two complete turns.

( c ) Center bubble In level by rotating these two levellng screns equally In opposite directions.

( d ) Rotate alidade through 1 , 6 0 0 m ~ l s ( 9 0 ° ) , and center bubble In level by ro ta t~ng thtrd levelrng screw.

Page 56: TM 9-1425-381-10-8

Quick Par. 4-1 1 OST OP

( e ) Repeat (a), (c ) , and (d ) above u n t ~ l bubble comes to rest centered in its vial In both of these posi t~ons.

( f ) Rotate alidade through 3 ,200 m ~ l s (180 '7 f rom its position in (a) above, bubble should remain centered in its vial If bubble comes to rest off center, adjust plate level as prescribed In TM 9 1 4 3 0 3 8 1 24

( 6 ) Verify that optical p l u m b ~ n g eyepiece reticle has remained centered over sta- t ~ o n marker . If necessary, center re t~c le as prescr~bed in ( 3 ) above.

(7) Insure that OST remains level within 2 graduations during laying procedures and repeat posit~oning and leveling operations as required.

( 8 ) Loosen OST telescope and horizontal clamp knobs, and point telescope at OLT. T~ghten clamp knobs.

( 9 ) Adjust telescope eyepiece u n t ~ l r e t~c le crosslines a re in focus.

( 1 0 ) Adjust telescope focus~ng tube u n t ~ l OLT is in focus.

( 1 1 ) Rotate azimuth screvv unti l reticle cross- lines are centered on OLT.

( 1 2 ) As d~ rec ted by OIC, verify that OST scale IS set to value entered on l ine 5 of the applicable azimuth laying compu- tation fo rm.

Page 57: TM 9-1425-381-10-8

Quick Par. 4-11

OST OP

( 1 3 ) Ad jus t focusing of microscope eyepiece. Ver i fy t h a t inver ter k n o b is set for ho r i - zonta l .

( 14) Rotate m ic romete r k n o b fo r d e c ~ m a l va lue o n m ~ c r o r n e t e r c i rc le scale, a n d ro ta te hor i zon ta l d r i ve k n o b fo r co in - c idence on hor izonta l c i rc le scale a t va lue recorded o n l i ne 5 of cornputa- t ion fo rm. Close c i rc le d r t v e cover , a n d ver i fy set t ing.

NOTE. I f requested by HLT OP, rec ip- rocal ly co l l imate OST wi th HLT by per- f o r m ~ n g ( 1 5 ) through ( 2 3 ) below, and then verify scale set t ing by per forming ( 2 4 ) through ( 2 8 ) below; otherwise pro- ceed t o ( 2 9 ) below.

( 1 5 ) Loosen OST telescope and horizontal c lamp knobs, and point telescope a t HLT. Tighten c lamp knobs.

NOTE. When se t t ing scales using hor- ~ z o n t a l dr ive knob or az imuth screw, always approach se t t ing by ro ta t ing knob or screw in clockwise d i rect ion. I f set t ing i s passed, ro ta te knob or screw counter- clockwise t o pass se t t ing in opposlte direction, and then ro ta te knob or screw clockwise to approach proper set t ing.

( 1 6 ) Rotate a z ~ m u t h screw u n t ~ l ver t ica l r e t - ic le crossl ine i s al ined on center of HLT autoref lect ion lens assembly housing.

( 1 7 ) Adjust OST te lescope focusing tube un t i l H I T autoref lector is sharply defined.

Page 58: TM 9-1425-381-10-8

Quick Par. 4-1 1 OST OP

Allow HLT OP t o al ine hts instrument on OST autoref lector .

Rotate azimuth and al t i tude screws u n t ~ l HLT autoref lector is centered on single vert ical ret ic le l ine, and edges of autore- f lector coincide wi th the intersections o f the double vert ical ret ic le l ines and hor- izontal ret ic le l ine. Repeat ( 1 8 ) and ( 1 9 ) above unt i l autore- f lector remains properly centered in te le- scopes of both theodoli tes. Announce and record reverse horizontal scale reading, and verify that i t corre- sponds wi th value previously recorded on l ine 6 of the applicable computation form, as directed by OIC. Record announced FA on l ine 8 of com- putat ion form. Repeat ( 1 5 ) through ( 2 1 ) above each t ime HLT is translated. Loosen OST telescope and horizontal clamp knobs, and point telescope a t OLT. Tighten clamp knobs. Rotate telescope focusing tube unt i l OLT is in focus. Rotate azimuth screw unt i l ret icle crossl ines are centered on OLT. As directed by OIC, verify that OST scales are set within 0 .05 mi l of value recorded on l ine 5 of computation form. I f not, rotate micrometer and horizontal drive knobs as necessary t o set the scales, and repeat sequence ( 1 5 ) through ( 2 1 ) above.

Page 59: TM 9-1425-381-10-8

Quick Par. 4- 11

OST OP

(28) As dl rected by OIC, ver i fy t h a t OST has remained level wi th ln 2 graduations, and t h a t crossl lnes o f optical p lumbing eye- piece have remained on center o f s tat ion marker .

(29) Stand by OST t o per fo rm reciprocal co l - l l m a t ~ o n w i th HLT i f requi red by HLT OP.

5 ( 1 ) Place hood over OST. (2) I f appl icable, close OST t e n t access

corner.

Af ter HLT OP presses MONITOR, close HLT t e n t wlndow used for v iewing OST.

7 (1 ) Af te r HLT OP presses COMPLETE swl tch on ALCB, close HLT t e n t window used for v iewlng ST 120

(2 ) Evacuate area NOTE Per fo rm the following only ~f

d i rected by supervisor t o per fo rm a hor izonta l lay recycle O t h e r w ~ s e , ~f an addl t ional m ~ s s i l e IS t o be frred, begln se quence 8 below, ~f evacuation IS required, per fo rm procedures In paragraph 5 11

( 3 ) Reenter area, proceed t o sequence l ( 1 ) above

8 Return t o f l r lng p o s i t ~ o n

Page 60: TM 9-1425-381-10-8

Quick Par. 4-11 OST OP

9 Disconnect 6 0 W 3 P 2 from J 6 on PS.

10 ( 1 ) Ass~s t HLT O P in moving and l ay~ng AND 6 0 W 4 3 and 6 0 W 4 4 t o PTS. 11 ( 2 ) Lay 6 0 W 4 3 to OST posl t~on.

(3) Remove hood from OST.

12 B e g ~ n sequence 1 above AND 13

Page 61: TM 9-1425-381-10-8

rosrrtrlng Par. 5-10

HLT OP

CHAPTER 5

POSTFIRING AND MISSILE RECAPTURE PROCEDURES

Section I. POSTFIRING PROCEDURES

5-10 . Duties of HLT OP

NOTE. Before rnaking cable connections, remove caps f rom connector and receptacle, and inspect electrical contacts. After connecting cable, mate connector cap with receptacle cap After disconnect~ng cable, install caps on connector and receptacle

Perform sequences in this paragraph only if last frrtng posrt~on IS being evacuated.

1 ( 1 ) Return to f ~ r i n g pos~t lon . AND

2 ( 2 ) Working with OST OP, pack azimuth laying equipment Insure that a l l azl- muth laying equipment IS properly stored and secured.

3 ( 1 ) Disconnect 60W44P1 from ALCB

( 2 ) Store ALCB in PTS.

4 No assigned d u t ~ e s AND 5

Page 62: TM 9-1425-381-10-8

Postfiring Par. 5-10 HLT OP

6 ( 1 ) Assist PTS OP in disconnecting 60W105 THRU f rom BCC or T 1500A

10 ( 2 ) Assist PTS OP in storing 60W105 on

auxiliary equipment t ruck

11 Assist PS OP in drsconnecting conditioned a i r duct f rom PS and in posit ioning ladder a t PS electrrcal d~strrbut ion center.

12 No assigned duties

13 ( 1 ) Assist CM 1 and other operators in placing and securing cable bundle and hrgh pressure arrhose to left rear azr muth r ing pedestal, across transporter below blast deflector, to right rear azi muth r ing pedestal, and along right side of EL

( 2 ) Assist CM 1 and other operators in placing and securing condit ioned-air duct across top of blast deflector and down right side of EL.

14 Store chocks and assume duty as driver of auxiliary equipment vehicle.

Evacuate area.

15 No assigned duties THRU

19

5-2

Page 63: TM 9-1425-381-10-8

postf iring Par. 5-11

OST OP

5-11. Duties of OST OP Perform sequences in thls paragraph only if last f ~ r ~ n g pos~t ion is belng evacuated

1 ( 1 ) Return to f ~ r ~ n g position. i THRU

10 ( 2 ) Worklng with HLT OP, pack a z ~ m u t h laying equipment. Insure that al l azl- muth l ay~ng equ~pmen t IS properly stored and secured.

11 Store 60W44 and 60W43 on a u x ~ l ~ a r y equip- ment vehlcle.

12 No ass~gned duties.

13 ( 1) Assist CM 1 and other operators in p lac~ng and securlng cable bundle and h~gh-pressure a ~ r h o s e to left rear azl- muth r ing pedestal, across transporter below blast deflector, to right rear azi- muth r lng pedestal, and along rlght stde of EL.

( 2 ) Assrst CM 1 and other operators in placlng and securing cond~t ioned-air duct across top of blast deflector and down r ight slde of EL.

14 No ass~gned duties

Evacuate area.

15 No asslgned d u t ~ e s THRU

19

Page 64: TM 9-1425-381-10-8

Recapture, WS Removal Par. 5-21 HLT OP

Section II. MISSILE RECAPTURE AND WARHEAD SECTION REMOVAL PROCEDURES

5 - 2 1 . Duties of HLT OP NOTE. Before making cable connections, remove caps

f rom connector and receptacle, and inspect electrical contacts. After connecting cable, mate connector cap with receptacle cap. After disconnect~ng cable, tnstall caps on connector and receptacle.

1 ( 1 ) Return to f i r ing position. THRU

3 ( 1.1 ) If directed, press RESET switch.

NOTE. If evacuation is not required, omit ( 2 ) below

WARNING: Do not disconnect 60W44 until power is turned off.

(2) Working wrth OSTOP, pack or reposition azimuth layrng equipment.

4 After mrssile has been lowered, observe ST- 1 2 0 prism and notify PTS OP and supervisor when pr ism is level.

NOTE. If evacuation is not required, omtt sequences 5 through 1 0 below.

5 ( 1 ) Disconnect 6 0 W l 8 P 2 from PTS f i re control cable entry panel.

( 2 ) Disconnect 60W18P1 from BCC or f rom RFB.

Page 65: TM 9-1425-381-10-8

Recapture, WS Removal Par. 5-21

HLT OP

( 3 ) Assisted by OST OP, store RFB and 60W 18 in PTS.

If WS 1s to be placed in WS container, begin sequence 1, paragraph 5 - 3 0

6 No ass~gned du t~es . AND

7

8 CAUTION: Use extreme care to prevent dam- AND aging the missile.

9 ( I ) Guide retaining ring half as OST OP rotates ring under CMA to upright position.

(2) Working with OST OP, lift and move ring half rearward until i t is alined with missile cradle.

( 3 ) Swing right rod-end connector into slot in missile cradle.

(4) At same time that OST OP torques left nut, torque nut on right rod-end connector (50 ft-lb).

10 N o assigned d u t ~ e s .

If evacuation 1s required, proceed to sequence 8, para- graph 5 - 1 0 .

Page 66: TM 9-1425-381-10-8

Recapture, WS Removal Par. 5-22 OST OP

5-22. Duties of OST OP NOTE. If evacuat~on is not required, omit a l l sequences

In t h ~ s paragraph.

1 ( 1 ) Return to f i r ~ n g position THRU

4 ( 2 ) Working with HLT OP, pack or reposl t ion azimuth l a y ~ n g equipment

5 Assist HLT OP rn storing RFB and 60W18 .

If WS is to be placed in WS conta~ner , b e g ~ n sequence 1, paragraph 5-31.

6 No assigned du t~es . AND

7

8 CAUTION: Use extreme care to prevent dam- AND aging missile during installation of retaining ring

9 half. (1) Obtain retaining ring half and place it

against left side of second stage at a posi- tion just aft of second stage-to-guidance section splice band with liner against mjs- sile skin.

(2) Working with HLT OP, rotate ring half under CMA to upright position; l i f t and move ring half rearward until i t is alined with missile cradle.

(3) Swing left rod-end connector into slot in missile cradle.

(4) At same time that HLT OP torques right nut, torque nut on left rod-end connector (50 ft-lb).

(5) Install ball lockpin to secure CMA to re- taining ring half.

5-6

Page 67: TM 9-1425-381-10-8

WS Removal Par. 5 - 3 0

HLT OP

10 No ass~gned d u t ~ e s .

If evacuation 1s required, proceed to sequence 8, para- graph 5 - 1 1 .

Section Ill. WARHEAD SECTION REMOVAL 5 -30 . Duties of HLT OP 1 N o ass~gned d u t ~ e s

A N D 2

3 NOTE. Perform this sequence only tf evacu- AND a t ~ o n is requ~red .

4 CAUTION: Use extreme care to prevent dam-

aging missile during installation of retaining ring half. (1) Guide retaining ring half as OST OP rotates

ring under CMA to upright position.

(2) Working with OST OP, lift and move ring half rearward until it is alined with missile cradle.

(3) Swing right rod-end connector into slot in missile cradle.

(4) At same time OST OP torques left nut, torque nut on right rod-end connector (50 ft-lb).

5 No ass~gned d u t ~ e s . THRU

1 3

If evacuation is required, proceed to sequence 8, para- graph 5 - 1 0 , omitt ing those steps prev~ously performed.

Page 68: TM 9-1425-381-10-8

WS Removal Par, 5-31 OST OP

5-31. Duties of OST OP

I N o assigned dut ies AND 2

3 NOTE. Perform this sequence only ~f evacu- AND at ion is required.

4

CAUTION: Use extreme care to prevent dam- aging missile during installation of retaining ring half. (1) Obtain retaining ring half and place it

against left side of second stage at a posi- tton just aft of second stage-to-guidance section splice band with liner agalnst mis- sile skin.

(2) Working with HLT OP, rotate ring half under CMA to upright pos~tion; l i f t and move ring half rearward untll i t is alined with missile cradle.

(3 ) Swing left rod-end connector into slot in missile cradle.

(4) At same time HLT OP torques right nut, torque nut on left rod-end connector (50 ft-lb).

5 N o assigned d u t ~ e s . THRU

13

If evacuat~on is required, proceed to sequence 8, para- graph 5 - 1 1 , om i t t~ng those steps prev~ously performed.

Page 69: TM 9-1425-381-10-8

Disassembly Par. 6-9 HLT OP

CHAPTER 6

MISSILE DISASSEMBLY PROCEDURES

Section I. MISSILE DISASSEMBLY

6-9 . Duties of HLT OP NOTE. Before making cable connections, remove caps

from connector and receptacle, and inspect electrical contacts. After connecting cable, mate connector cap wrth receptacle cap. After dtsconnecttng cable, install caps on connector and receptacle,

1 Drive auxtliary equrpment vehicle into post- tron as directed by OST OP, set vehrcle brakes.

2 ( 1 ) Working w ~ t h PTS OP, obtain tools f rom toolboxes and place them on rear of auxiliary equipment vehicle.

( 2 ) D~st r rbute tools as required

3 WARNING: Do not release WS handling de- vice until wrecker hook is connected. From the ground, and after wrecker hook IS connected to WS handling device, loosen outboard rear nut securing WS handlrng de- vice to EL mounttng block, and swing nut free of slot in base of WS handl ing dev~ce.

Page 70: TM 9-1425-381-10-8

Disassembly Par. 6-9 HLT OP

4 Workrng w ~ t h other operators, remove cable bundle, cond~t~oned-ar r duct, and h~gh-pressure atrhose from srde and rear of EL and lay cable bundle, condr t~oned-a~r duct, and high- pressure a~ rhose on ground as d~ rec ted .

Remove gu~dance section blanket end cover.

Remove covers f rom upper and left bolts on gurdance section-to-WS splrce band.

D~sconnect cable f rom upper exploslve bol t cartrrdge.

Install cap on explos~ve bolt ca r t r~dge cable.

WARNING: Exercise caution when handling explosive bolt cartridge.

Remove upper explos~ve bolt cartridge from exploslve bolt; rnstall cap on car- t r ~ d g e and plug ~n bolt.

Pass explos~ve bolt ca r t r~dge to CAS.

W h ~ l e holding lower half of spirce band, loosen left torque bolt tn band enough to aliow removal of bolt.

W o r k ~ n g wrth OST OP, remove bolts a n d lower half of spllce band, and carefully place band on forward end of EL.

Working with OST OP, p o s ~ t ~ o n upper half of sp l~ce band on forward end of EL.

Page 71: TM 9-1425-381-10-8

Disassembly Par. 6-9 HLT OP

6 NOTE. Perform (1) through ( 4 ) below for each separation spring.

( 1 ) Obtain compression tool and insert flange of compression tool over plunger of each separation spring assembly so that flange is po~nted toward center of guidance sect~on. Push in and rotate tool body clockwise so that flange 1s securely seated on inside surface of guidance section structural ring.

WARNING: Separation springs require 380 kilograms (850 pounds) of pres- sure to compress. Make certain that compression tool is securely seated be- fore removing spring retaining tool. To prevent unintentional rotation of com- pression tool body, hold compression tool body while spring is being decom- pressed.

( 2 ) Hold compression tool body and turn crank clockwise u n t ~ l spring retaining tools can be removed.

( 3 ) Hold compression tool body and turn crank counterclockw~se until shaft 1s completely retracted.

( 4 ) Rotate compression tool body counter- clockw~se until flange is disengaged.

( 5 ) Store compression tool and sprlng re- ta in~ng tools in travel position.

Page 72: TM 9-1425-381-10-8

Disassembly Par. 6-9 HLT OP

7 No assigned duties. THRU

1 3

14 ( 1 ) Disconnect cable from lower explosive bolt cartridge on 1st-to-2nd stage spl~ce band.

( 2 ) Install cap on explosive bolt cartr~dge cable.

WARNING: Exercise extreme caution when handling explosive bolt cartridge.

( 3 ) Remove lower explos~ve bolt cartridge from explosive bolt; install cap on car- tridge and plug ~n bolt.

( 4 ) Pass explosive bolt cartridge to MH 4 .

15 No assigned duties

1 6 WARNING: Handle initiators one at a time.

Receive initiators one at a time from PTS OP and pass to CAS.

17 No assigned duties THRU

1 9

20 Guide cable bundle, conditioned-air duct, and hrgh-pressure airhose around EL as CMA is positioned onto EL.

Page 73: TM 9-1425-381-10-8

Disassembly Par. 6-10

OST OP

21 ( 1 ) Working with other operators, place and AND secure cable bundle and hlgh-pressure 2 2 airhose to left rear a z ~ m u t h r ing

pedestal, across transporter below blast deflector, to right rear azimuth r ing pedestal, and along right side of EL.

(2) Worklng vvlth other operators, place and secure condit ioned-alr duct across top of blast deflector and dovvn r ight side of EL.

23 Working with OST OP, store al l tools and loose AND items. 24

25 Assume duties as driver of auxiliary equipment vehicle, and when directed, drive vehrcle out of area.

6 - 10. Duties of OST OP NOTE. Before ma king cable connections, remove caps

f rom connector and receptacle, and ~nspec t electrical contacts. After connecting cable, mate connector cap with receptacle cap. After disconnecting cable, install caps on connector and receptacle.

1 Guide auxilrary equipment vehlcle into post. tion and chock the wheels.

2 Receive air vanes f rom CM 1 and 2; place AND 1st and 2nd stage a l r vanes on respective

3 container truck.

4 W o r k ~ n g with other operators, remove cable bundle, condi t ioned-a~r duct, and hlgh-pressure airhose f rom s ~ d e and rear of EL and lay

Page 74: TM 9-1425-381-10-8

Disassembly Par. 6-10 OST OP

cable bundle, condlttoned-air duct, and high- pressure airhose on ground as directed.

5 ( 1 ) Remove covers from lower and right bolts on gu~dance sect~on-to-WS splice band.

( 1 . I ) Disconnect cable from lower explos~ve bolt cartrldge.

( 2 ) lnstail cap on explosive bolt cartridge cable.

WARNING: Exercise cautionwhen han- dling explosive bolt cartridge.

( 3 ) Remove lower exploslve bolt cartr~dge from exploslve bolt; install cap on car- tridge and plug in bolt.

( 4 ) Pass explos~ve bolt cartrldge to CAS.

(5) Whlle hold~ng lower half of splice band, loosen right torque bolt in band enough to allow removal of bolt.

( 6 j Working with HLT OP, remove bolt and lower half of splice band, and care- fully place splice band below guidance sect~on.

( 7 ) Working with HLT OP, position upper half of sptice band under guidance sec- t1on.

6 As guidance section separation sprlngs are decompressed, remove spring reta~nlng tools and lay them aside for later storage.

Page 75: TM 9-1425-381-10-8

7 THRU

1 2

15 AND 16

17 AND 1 8

Disassembly Par. 6 - 1 0

OST OP

Obtain 2nd stage-to-guidance sect~on retain- ~ n g band and attaching hardware from CM 1 and 2; place band and attaching hardware on 2nd stage contamer truck.

Obtain 1st-to-2nd stage splice band and at- taching hardware from CM 1 and 2; place band and attaching hardware on 1st stage contarner truck.

Guide 2nd stage hoisting beam to ground.

No assigned duties.

Obtain and hand retaining ring half to CM 1.

Guide cable bundle, conditioned-air duct, and high-pressure airhose around EL as CMA is posit~oned onto EL.

( 1 ) Connect wrecker hook to 2nd stage hoistlng beam; gulde ho~sting beam as it IS ra~sed.

Page 76: TM 9-1425-381-10-8

Change Target Par. 7-13 VLT OP

( 2 ) Connect wrecker hook to 1st stage hotst- Ing beam; guide holstlng beam as ~t 1s ralsed.

23 ( 1 ) (Deleted) THRU

2 5 ( 2 ) Connect wrecker hook to hoisting link

on protector-sllng.

( 3 ) Working with HLT OP, store all tools and loose items.

CHAPTER 7 OPERATION UNDER UNUSUAL

CONDITIONS

Section Ill. CHANGE OF TARGET

7-13 . Dutiesof VLTOP

1 ( 1 ) After rnissrle rs erected and necessary rotation 1s completed, determlne em- placement locatlon for VLT as follows. Uslng tllumlnated sunshade assembly as a guide, determlne locatlon, approx- imately 16 meters ( 5 2 feet) from mls- slle, from whlch a reflected Image of one's self can be seen in ST- 120 prlsm.

Page 77: TM 9-1425-381-10-8

Change Target Par. 7-13

VLT OP

If terrain conditions at this location will not permit emplacement of VLT, move toward or away from m iss~ le to acqurre acceptable terrain conditrons Usrng a pencil or other available object, o r by some suitable means (heel of shoe), mark point on ground directly under positron where reflected image was o b served For night operatrons, refer to paragraph 7 2 6

WARNING: Do not disconnect 60W44 from ALCB.

( 2 ) D~sconnect autoreflection lens assembly cable f rom ALCB Install cover on ALCB, and place ALCB in a safe area

( 3 ) Loosen carriage thumbscrew and move carriage to center of bed assembly Tighten thumbscrew

CAUTION: Insure that two men are used for lifting and moving HLT.

( 4 ) When d ~ r e c t e d by supervisor a n d assisted by OST OP, move HLT to po s ~ t i o n determined in ( 1 ) above Position tr ipod so that semifixed leg is pornted toward m iss~ le and tripod spreader is d~rec t ly over marked pornt on ground

NOTE HLT is now designated VLT

( 5 ) Install ALCB on tr ipod Remove ALCB cover and connect autoreflectron lens assembly cable to THEOD LAMP re ceptacle on ALCB

Page 78: TM 9-1425-381-10-8

Change Target Par. 7-13 VLT OP

2 ( 1 ) If necessary, loosen chuck on semif~xed leg and extend leg so that theodolite will b e at a conven~ent height for op. eration: t ighten chuck.

NOTE, Insure that chucks on adjust- able legs are loose enough to permit operation of handcranks, but not loose enough to allow tripod to wobble. Before ope ra t~ng handcranks, support upper portion of tr ipod so that adjustable legs can be extended and retracted without binding.

( 2 ) Level t r ipod by operating handcranks unti l bubble In t r ipod level is centered.

( 3 ) Insure that theodolite horizontal circle ~ l luminat ing mi r ror is open.

( 4 ) Loosen telescope and horizontal clamp knobs, and sight telescope on center of ST-120 pr ism nindow. Adjust telescope focusing tube as required.

( 5) Rotate telescope eyepiece unti l reticle is sharply defined.

( 6 ) Loosen carriage thumbscrew and move carriage unti l reflected image of auto- reflector can be seen through telescope. Tighten carriage thumbscrew and clamp knobs.

NOTE. If leveling has been prev~ously performed, adjust screws only as re- quired to achieve level cond i t~on.

Page 79: TM 9-1425-381-10-8

Change Target Par. 7-13

VLT OP

( 7 ) Loosen horrzontal clamp knob and turn three leve l~ng screws fully counterclock wise then perform fine leve l~ng as follows

( a ) Rotate a l ~ d a d e unti l axis of plate level rs parallel to a Irne through any two of the three leve l~ng screws

( b ) Turn these two screws clockw~se two complete tu rns

( c ) Center bubble in level by rotat ing these two leveling screws equally in oppos~te d i rec t~ons

( d ) Rotate a l ~ d a d e through 1 , 6 0 0 m ~ l s ( 9 0 ° ) , and center bubb le rn level by rotating thrrd leveling screw

( e ) Repeat (a) , ( c ) , and (d ) above unti l bubble comes to rest centered In ~ t s v ~ a i In both of these pos~t ions

( f ) Rotate alidade through 3 , 2 0 0 m ~ l s ( 1 8 0 " ) f rom rts posttion in (a) above, bubble should remain centered in ~ t s v ~ a l If bubble comes to rest off center, adjust plate level as prescribed in TM 9 1 4 3 0 3 8 1 1 4

( 8 ) Repeat pos l t ion~ng and leveling oper ations as required

( 9 ) Request OIC to verify VLT level

NOTE Insure that VLT remalns level dur ing l a y ~ n g procedures if not, repeat laytng procedures

Page 80: TM 9-1425-381-10-8

Change Target Par. 7-13 VLT OP

3 ( 1) Loosen VLT telescope and horizontal clamp knobs, and rotate alidade unt i l OST telescope can be seen through VLT telescope. Tighten clamp knobs.

NOTE When setting scales using horizontal drive knob or azimuth screw, always approach settlng by rotating knob or screw in clockwise direction If setting IS passed, rotate knob or screw counter clockwise to pass setting in opposite direc- tion, and then rotate knob or screw clockwise to approach proper setting

( 2) Rotate azimuth screw unti l ver t~ca l reticle lines are alined on center of OST auto- reflection lens assembly housing. Adjust telescope eyepiece as required to focus reticle.

( 3 ) Adlust telescope focuslng tube on theod- olite unti l OST autoreflector is sharply defined.

( 4 ) Rotate azimuth and a l t~ tude screws u n t ~ l autoreflector is centered on single verti. cal reticle line, and edges of auto- reflector colncide with intersections of double vertical reticle lines and hor i - zontal reticle Iine.

( 5 ) A l l o . ~ OST OP to aline on VLT auto- reflector.

( 6 ) Repeat ( 4 ) and ( 5 ) above unti l auto- reflector remains properly centered in

7 -4 telescopes of both theodolites.

Page 81: TM 9-1425-381-10-8

Change Target Par. 7-13

VLT OP

( 7 ) Adjust focusrng of mrcroscope eyepiece. Verlfy that inverter knob is set for horl- zontal.

( 8 ) Rotate VLT micrometer knob for decimal value on micrometer crrcle scale, and rotate hor~zonta l dr lve knob for coin- c~dence on hor~zonta l clrcle scale at value announced by OST OP Close horr- zontal clrcle dr ive cover and verlfy read- ing.

( 9 ) Request supervisor to verrfy reciprocal col l lmat~on of VLT with OST.

( 10) Rotate micrometer knob to decrmalvalue of firrng azimuth.

( 1 ) Loosen VLT horizontal c lamp knob, and rotate alrdade unt i l horizontal clrcle scale rndrcates approximate value of frr ing a z ~ m u t h . Tighten clamp knob.

( 2 ) Verlfy that micrometer knob 1s set cor- rectly, and rotate azimuth screw unti l horrzontal clrcle scale lndlcates exact value of f l r ing azimuth.

( 3 ) Loosen telescope clamp knob and ro- tate telescope to dpproxlmate posltion requlred to vrew pr lsm. Tighten clamp knob.

( 4 ) Rotate alt l tude screw as requlred to view ST-120 pr lsm window, and observe if reflected Image of autoreflector can b e seen In telescope.

Page 82: TM 9-1425-381-10-8

Change Target Par. 7-13 VLT OP

( 5 ) If autoreflector is not visible, translate VLT, and proceed to sequence 3 above; if autoreflector is visible, proceed to ( 6 ) below.

( 6 ) Adjust telescope focusing tube unti l autoreflector is sharply defined in reticle.

5 ( 1 ) When LAY PLATF indicator flashes, set and hold PLATF CONTROL switch to appropr late L or R position and rotate VLT alt l tude screw u n t ~ l autocoll~matron is achleved (autoreflector is centered on single vertical reticle line, and edges of autoreflector coinclde with intersectrons of double vertical reticle lines and horr zontal reticle Ilnes) If a faster ST 1 2 0 rotational speed is requlred to achieve autocollimation, proceed to ( 2 ) below, otherwise, proceed to ( 3 ) below

( 2 ) Press RESET switch, set and hold PLATF CONTROL swrtch to approprlate L or R pos~t ion unti l autoreflector IS approxi mately centered rn reticle, and proceed to ( I ) above

( 3 ) When satisfied that autoreflector will r e main ~n alinement without fur ther ad justment, request OIC to verify auto collrmatron and horizontal scale sett ing to FA, notify supervisor that MONITOR switch can be pressed

NOTE When MONITOR switch is pressed (MONITOR lndlcator lrghts and

Page 83: TM 9-1425-381-10-8

Change Target Par. 7-13

VLT OP

LAY PLATF indicator goes out), the 60- second optical mon~toring period is initiated. During this time, the autore- flector is lighted for 55 seconds and then flashes for 5 seconds.

NOTE. Angular drsplacement (drift) of ST-120 may be estimated by using the lateral distance between the double vertical reticle lines as a reference. The angle represented by this distance is approximately 0 .2 mil.

( 4 ) When directed by supervisor, press MONITOR switch, and mon~tor ST-120 to determine if its drift rate is within 0.1 mil In 6 0 seconds (vertex of auto- reflector remained within double vertical reticle lines); ~f ST-120 drift rate is out of tolerance, notify supervisor.

NOTE. After monitoring period ends, approx~mately 9 0 seconds elapse before LAY PLATF indicator starts flash- ing, periodically observe autoreflector to determine that d r ~ f t does not exceed 0 2 m ~ l outside of either double vertical reticle line during this t~me. ( I f RESET switch has been pressed, or durlng horizontal lay recycle, LAY PLATF indl cator starts flashing without delay at end of optlcal monitoring period.)

Page 84: TM 9-1425-381-10-8

Change Target Par. 7-13 VLT OP

6 ( 1 ) When LAY PLATF indicator flashes, if ST 1 2 0 dr i f t rate was out of tolerance dur ing optical mon i to r~ng period, or autoreflector is now d~splaced more than 0 2 mi l ou t s~de of either double vertical reticle I ~ n e , notify supervisor, press RE SET switch, and proceed to sequence 5 ( 1 ) above, if ST 1 2 0 dr i f t is within tolerance, notify supervisor that COM PLETE switch can be pressed

NOTE If directed by supervisor, again monitor ST 1 2 0 to determine if its d r i f t rate is within 0 1 mi l in 6 0 seconds If d r i f t rate is out of tolerance, notify supervisor, press RESET switch, and proceed to sequence 5 ( 1 ) above, if clrift is within tolerance, notify super visor that COMPLETE sw~tch can b e pressed

( 2 ) When directed by supervisor to press COMPLETE switch, center autoreflector in reticle, if necessary, by setting and holding PLATF CONTROL switch, then press COMPLETE switch

( 3 ) Notify supervisor that COMPLETE switch has been pressed.

WARNING: Do not disconnect 60W44 from ALCB.

( 1 ) Install cover on ALCB and position ALCB under f ront of EL.

Page 85: TM 9-1425-381-10-8

Change Target Par. 7 - 1 4

OST OP

( 2 ) Assisted by OST OP, evacuate VLT to safe area; evacuate area.

NOTE. Perform ( 3 ) through ( 5 ) below only if directed by supervisor to perform a vertical laying recycle

( 3 ) Reenter area.

( 4 ) Assisted by OST OP, emplace VLT and ALCB (seq 1 above).

(5) Proceed to sequence 2 above

7-14. Dutiesof OSTOP

1 ( 1 ) Using a z ~ m u t h laying computation and recording form (l ines 1 3 through 1 7 ) ( f ig 3 6 ) . compute value and direction of inissile rotation Announce value and direction

(2) When directed by supervisor, assist VLT OP in positioning VLT for vertical laying.

WARNING: Do not disconnect 60W44 from ALCB.

CAUTION: When performing (3) be- low, grasp ALCB and 60W44 to prevent cable from twisting.

( 3 ) Move ALCB to VLT.

No assigned duties

( 1 j Rotate OST unti l VLT telescope can be seen through OST telescope

Page 86: TM 9-1425-381-10-8

Change Target Par. 7-14 OST OP

( 2 ) Acljiist OST urlt i l vertlcal retrcle lrne is alinetl on the center of autoreflection leris assernbly housing of VLT

( 3 ) Acljust OST uritil autoreflector of VLT is sharply defi i ied, arid then unti l auto reflector is centered on the siiigle verti cal r e t~c le Iiiie, and edges of autore flector coincide w ~ t h intersections of double vertical r e t~c le lines and hor i zorital reticle l ine

( 4 ) Allow VLT OP to aiine VLT on auto- reflector of OST

( 5 ) Repeat ( 3 ) and ( 4 ) above unt i l auto- reflector reniains properly centered In reticles of both theodolites

( 6 ) Adjust focusing of microscope eyeplece Verify that ~nve r te r knob I S set to h o r ~ zontal

( 7 ) Request OIC to verify alinement with VLT arid reverse horrzon tal scale se t t~ng.

( 8 J Record and announce reverse horizontal scale reading (reading 1 3 , 2 0 0 m ~ l s ) on line 18 of co~npi l tat ion form

4 ( 1 ) Rotate OST uritil OLT can be seen AND throilgh telescope. 5

Page 87: TM 9-1425-381-10-8

Change Target Par, 7-14

OST OP

NOTE. When setting scales using horizontal drive knob or azimuth screw, always approach setting by rotating knob or screw in clockwise direction. I f setting is passed, rotate knob or screw counter- clockwise to pass setting in opposite direc- tion, and then rotate knob or screw clockwise to approach proper setting.

( 2 ) Adjust telescope unti l OLT is in proper focus and alinement.

( 3 ) Read scale and compare with value for l lne 5 on computation form. If values dl f fer more than 0 .025 mil, repeat se- quence 8, paragraph 3 - 1 4 .

( 4 ) Verlfy that OST has remained level and that optlcal p lumblng eyepiece reticle has remalned on center of statlon marker .

( 5 ) Request OIC to verlfy OST horizontal scale settlng, level, and optrcal p lumb.

( 1 ) Place hood over OST.

( 2 j Close OST tent access corner. ~f a p plicable.

Page 88: TM 9-1425-381-10-8

Change Target Par. 7-14 OST O P

A s s ~ s t VLT OP in evacuat ing VLT t o a safe a rea ; evacuate a rea .

NOTE. P e r f o r m ( 2 ) th rough ( 9 ) b e low only i f d i rected b y supervisor to p e r f o r m a ver t ica l lay ing recycle

Reenter area.

Assist VLT OP i n posi t ion ing VLT a n d ALCB (seq 1 ( 2 ) a n d ( 3 ) a b o v e ) .

Reinove hood f r o m OST.

Ver i f y OST scale set t ing (seq 4 above)

Rec~proca l l y collhrnate OST w i th VLT (seq 3 above)

V e r ~ f y OST scale set t ing (seq 4 above)

Place hood over OST

Assist VLT O P in e v a c u a t ~ n g VLT, evacuate area

Page 89: TM 9-1425-381-10-8

By Order of the Secretary of the Army:

W. C. WESTMORELAND General, United States Army

Official: Chief of Staff VERNE L. BOWERS Major General, United States Army The Adjutant General

Distribution: To be distributed in accordance with

DA Form 12-32 (qty rqr block No. 48) organizational maintenance requirements for PERSHING Missile System.

xt U. S. GOVERNMENT PRINTING OFFICE : 1871 0 - 467-317

Page 90: TM 9-1425-381-10-8
Page 91: TM 9-1425-381-10-8