- Ozone resistant.
- High dielectric strength.
- Light, practical and safe.
- Suitable for voltages up to 48.3 kV (phase-phase).
- Temporary protection for energized systems maintenance.
- Better working area visualizing, due to its orange color.
- Ozone resistant.
- High dielectric strength.
- Light, practical and safe.
- Suitable for voltages up to 48.3 kV (phase-phase).
- Temporary protection for energized systems maintenance.
- Better working area visualizing, due to its orange color.
ISO 9001 FLV-102I-00
PROTECTIVE COVERS
FOR HOT LINES
PROTECTIVE COVERS
FOR HOT LINES
PROTECTIVE COVERS
FOR HOT LINESQ U A L I T Y
S A F E T Y
Q U A L I T Y
S A F E T Y
PROTECTIVE COVERS FOR PIN AND PILLARINSULATORS
These covers are used to protect an energized conductor close to a cap pin or pillar insulator, being normallyused together with the conductor covers, to which they can be connected using the standardized fittings.
There are three available models, one for each type of job and voltage level:
- M 4947 - Traditional model to be used with regular pin insulators and pollution-proof pin insulators .
- FLV-11050 - New resized model to be used with porcelain, tempered glass or polymeric pin insul ator, besidespillar insulators. Due to its reduced shape, this protective cover is perfect for CDS (Compact DistributionSystems), where the space between the phases is smaller than usual.
- C406-0046 - It divided in two pieces, that are used superposed, providing a high dielectr ic strength, allowing itto be used in voltages up to 48.3 kV.
All the models have metallic eyes, which allow them to be installed by using a grip-all stick.
360
190
SYNTHETICROPE
8mm Nominal Voltage: 26,4 kV (Phase/Phase)
Nominal Voltage: 26,4 kV (Phase/Phase)
Nominal Voltage: 48,3 kV (Phase/Phase)
Test Voltage: 24 kV (Phase/Ground)
Test Voltage: 24 kV (Phase/Ground)
Test Voltage: 42 kV (Phase/Ground)
CATALOGNR.
CATALOGNR.
CATALOGNR.
DESCRIPTION
DESCRIPTION
DESCRIPTION
APPROX.WEIGHT (kg)
APPROX.WEIGHT (kg)
APPROX.WEIGHT (kg)
0,70
0,80
4,00
Protective cover pin insulator
Protective cover pin and pilar insulator
Protective cover pin insulator
M4947
FLV-11051
C406-0046
Sucessora da RITZ-CHANCE
Rod. BR 381 - Km 430 - CP.: 54 - CEP.: 32530-000 - Betim - MGPhone: (55 31) 3539.7000 - Fax: (55 31) 3539.7100
e-mail: [email protected] site: www.ritzbrasil.com.br
November/2000
NOTES:
1) The drawings of this catalog are ilustrative and the dimensions are only for reference and could suffervariations.
2) Since the Ritz do Brasil has a policy of continuous product improvement, it reserves the right to changedesign and specifications without notice.
215
150
330
SYNTHETICROPE
864
1015(MAX.)
335
335
SYNTHETICROPE6mm GRIP ALL ADAPTER
800 (MIN.)
-
7/27/2019 tips-0-2002
2/4
USE, HANDLING AND MAINTENANCE
The PROTECTIVE COVERS FOR HOT LINES, are one of the most important equipments used whenworking with low, medium and high voltage energized systems.It is used to insulate electrically the working area, avoiding contacts between phases or phase-ground,during the maintenance jobs.The PROTECTIVE COVERS FOR HOT LINES are essential during Bare Hand maintenance. The coversare installed with rubber gloves or at distance, using the gripp-all stick.Only linemen trained for hot line jobs should install them.The following rules shall be taken into consideration:
01 - Use only the PROPER COVER speci ally constructed to isol ate conductors, pin insulators, cappin insulators cutout switches, knife switches, shackles, spacers, a.s.o.IMPORTANT:
Allways use rubber gloves in order to touch or instal protective covers. The linemen must be aware of thisworking position and working distance from the protective covers, avoiding accidental contact. This arebasic rules for any other cover used to protect energized parts.
02 - The protective covers for: poles, crossarms, horizontal supports, "C" supports and the circular coversare used to avoid contact between energized conductors or lashings and the grounded structuresurface.
03 - The protective covers shall be ha ndled carefully, to avoid breaking, cracking or scratching it. Theyshould also be kept clean and dry.Each protective cover must be carefully checked before its use, assuring that there are no cracks, deepscratches, changes of shape or other damages, and that they are clean and dry .If not clean they shall be cleaned with a dry cotton cloth. If this does not remove all the dirt, water andneutral soap can be used.
04 - Protective Covers are for TEMPORARY USE only.They should be taken off, whenever poss ible, at the end of each working day.
1
Q U A L I T Y
S A F E T Y
Q U A L I T Y
S A F E T Y
Q U A L I T Y
S A F E T Y
PRECAUTION
The protective covers have been designed in order to be used in many different working-situations. Theline men have to select carefully the most appropriate cover for each equipment avoiding dangerousimprovisations. Before/starting any maintenance-job the availability of the right covers in sufficientquantify has to be checked.The maintenance-job has to be postponed if there are not correct, clean and sufficient covers available. Theprotective covers are not designed to avoid contacts wheneve r using mechanical equipment.
TECHNICAL CHARACTERISTICS
The RITZ PROTECTIVE COVERS FOR HOT LINE, are made with high dielectric strength and ozoneresistant plastic.Its orange color, allows it to be seen easily, providing not only insulating protection but also an easyidentification of the working area.The protective covers des igned to be installed from the ground, have aluminum eyes, allowing its install ationto be made with a grip-all stick.THE RITZ PROTECTIVE COVERS FOR HOT LINES ARE MADE IN COMPLIENCE TO ASTM-F968STANDARD AND TESTED ACCORDING TO ASTM-F712 STANDARD.
6
These covers are used as a protection device, in the structures where there are cutout or knife switches. Theycan be installed with insulating gloves or from distance with a grip-all stick.
The knife switch cover is installed placing its longitudinal channeling between the two insulator sheds, to whichit is fixed by pressure.
The cutout switch cover is fixed with a wooden pin, which locks itself behind the insulator and sits over theswitch metallic support.
670
420
180
WOODENPIN
130
920
9513
174
4
Nominal Voltage: 26,4 kV (Phase/Phase)Test Voltage: 24 kV (Phase/Ground)
Q U A L I T Y
S A F E T Y
PROTECTIVE COVERS FOR CUTOUT ANDKNIFE SWITCHES
CATALOGNR.
DESCRIPTIONAPPROX.
WEIGHT (kg)
2,80Protective covers for cutout switchesC406-0009
Nominal Voltage: 26,4 kV (Phase/Phase)Test Voltage: 24 kV (Phase/Ground)
CATALOGNR.
DESCRIPTIONAPPROX.
WEIGHT (kg)
2,60Protective covers for knife switchesCI/CF-27
Q U A L I T Y
S A F E T YPROTECTIVE COVERS FOR CAP PIN INSULATORSThese covers protect energized parts around cap pin insulators and dead-end assembli es.
They have fittings in their ends. One end is for connection with the insulator and the other end is for connectionwith the conductor cover.
There are two available models: the traditional M4948, exclusive for cap pin insulators, and the new M4948-1model, with reduced size and lighter than the first one, also for cap pin insulators, besides polymeric and solidporcelain insulators.
Both models have metallic eyes, which allow them to be installed by using a grip-all stick.
260
680
465
SYNTHETIC ROPE
6 mm
WOODENPIN
Nominal Voltage: 36,6 kV (Phase/Phase)
DESCRIPTION APPROX.WEIGHT (kg)
CATALOGNR.
M4948
Protective cover for
cap pin insulator.Up to 266mm 1,90
DESCRIPTION APPROX.WEIGHT (kg)
CATALOGNR.
INDEVEL
OPME
NT
Nominal Voltage: 26,4 kV (Phase/Phase)
Test Voltage: 24 kV (Phase/Ground)
M4948-1 1,60
Protective cover for dead-end,polymeric, solid porcelain and cappin insulators. Up to 160mm .
INDEVELOPMENT
Test Voltage: 32 kV (Phase/Ground)
-
7/27/2019 tips-0-2002
3/4
These covers are used as an additional insulating device wheninstalling or replacing poles.
They have synthetic rope handles, to make its installation andremoval, easy to be done with rubber gloves .
The 1.200 mm and 1.800 mm length models, have a nylon cuff link thatallows connecting two or more covers, in order to protect a largerarea.
The inner fillets keep the insulating walls of the covers from touchingthe pole, what prevents grinding and contamination, granting bettergrip and protecting the insulating layer of the cover.
There are two diameter available: one to protect poles up to 230 mmdiameter and another to protect poles up to 300 mm diameter. Thelengths go from 300 mm through 1.800 mm.
A
B
C
SYNTHETIC ROPE
A
C
B
CATALOGNr.
LENGTH (mm) APPROX.WEIGHT (kg)
M4937-1
M4937-2
M4937-4
M4937-6
Nominal Voltage: 36,6 kV (Phase/Phase)
Test Voltage: 32 kV (Phase/Ground)
300
600
1.200
1.800
1,20
2,20
5,00
7,50
A B C
230
230
230
230
~195
~195
~195
~195
Q U A L I T Y
S A F E T Y
POLE PROTECTIVE COVERS
FOR POLES WITHDIAMETERS UP TO 230 mm
FOR POLES WITHDIAMETERS UP TO 300 mm
C406-0028
C406-0029
C406-0030
C406-0000
300
600
1.200
1.800
1,50
2,50
5,80
8,10
A B C
300
300
300
300
~115
~115
~115
~115
CATALOGNr.
APPROX.WEIGHT (kg)
LENGTH (mm)
Nominal Voltage: 36,6 kV (Phase/Phase)
Test Voltage: 32 kV (Phase/Ground)
Q U A L I T Y
S A F E T Y
ROUND PROTECTIVE COVERS
Due to its versatility, these covers are adequate to protect pole tops,angle braces, crossarms, lightning arresters and so on.
Since they don't have a well defined application, each use requiresspecial consideration in order to decide whether or not the cover willoffer the necessary protection.
It has a synthetic rope handle to make its installation and removal aneasier task to be done with rubber gloves .
CATALOGNr.
LENGTH (mm) APPROX.WEIGHT (kg)
A B C A B C
CATALOGNr.
APPROX.WEIGHT (kg)
LENGTH (mm)
WITH DIAMETERSUP TO 100 mm
WITH DIAMETERSUP TO 150 mm
M4926-12
M4926-24
M4926-36
300 0,40100 ~196
600 0,80100 ~196
900 1,20100 ~196
Nominal Voltage: 14,6 kV (Phase/Phase)
Test Voltage: 13 kV (Phase/Ground)
M4936-12 300 0,50150 ~135
M4936-24 600 0,90150 ~135
M-4936-36 900 1,30150 ~135
Nominal Voltage: 14,6 kV (Phase/Phase)
Test Voltage: 13 kV (Phase/Ground)
2
A
B
C
SYNTHETIC ROPE8mm
5
55
132048
These covers are the ones which protect most of the energized conductors, and therefore, they are the mostcommon ones regarding hot line jobs.
There are many models available in order to satisfy the necessity of protection of the various types of electricalsystems with nominal voltage up to 48.3 kV.
Its ends have a fitting device which allows connection of two or more conductor covers, or even other types ofcovers, such as pin insulator covers and cap pin insulator covers .
Some models have metallic brackets with eyes, which allows the covers to be installed using a grip-all stick.
Q U A L I T Y
S A F E T Y
CONDUCTOR PROTECTIVE COVERS
FOR LOW VOLTAGE CONDUCTOR
Nominal Voltage: 14,6 kV (Phase/Phase)
Test Voltage: 13 kV (Phase/Ground)
CATALOGNR.
DESCRIPTION APPROX.WEIGHT (kg)
0,50
Low Voltage conductorprotective cover .Up to 25mm M4946BT
FOR HIGH VOLTAGE CONDUCTOR
1525
90
130
PRESILHA Nominal Voltage: 26,4 kV (Phase/Phase)
Test Voltage: 24 kV (Phase/Ground)
CATALOGNR.
DESCRIPTION APPROX.WEIGHT (kg)
High Voltage conductor protective cover.Up to 25mm M4946 1,00
1470
126
188
Nominal Voltage: 36,6 kV (Phase/Phase)
Test Voltage: 32 kV (Phase/Ground)
FLV-3631
* This cover is also available with open end. In this case, an "R" should be added to its catalog number, which would be: FLV-3631R
CATALOGNR.
DESCRIPTION APPROX.WEIGHT (kg)
* High Voltage conductor protective cover.Up to 25mm 2,20
1836
R91
285
Nominal Voltage: 48,3 kV (Phase/Phase)
Test Voltage: 42 kV (Phase/Ground)
CATALOGNR.
DESCRIPTION APPROX.WEIGHT (kg)
High Voltage conductor protective cover.Up to 45mm 4,30M4931
-